1
|
Ouyang L, Chen H, Xu R, Shaik R, Zhang G, Zhe J. Rapid Surface Charge Mapping Based on a Liquid Crystal Microchip. Biosensors (Basel) 2024; 14:199. [PMID: 38667192 PMCID: PMC11047892 DOI: 10.3390/bios14040199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/05/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024]
Abstract
Rapid surface charge mapping of a solid surface remains a challenge. In this study, we present a novel microchip based on liquid crystals for assessing the surface charge distribution of a planar or soft surface. This chip enables rapid measurements of the local surface charge distribution of a charged surface. The chip consists of a micropillar array fabricated on a transparent indium tin oxide substrate, while the liquid crystal is used to fill in the gaps between the micropillar structures. When an object is placed on top of the chip, the local surface charge (or zeta potential) influences the orientation of the liquid crystal molecules, resulting in changes in the magnitude of transmitted light. By measuring the intensity of the transmitted light, the distribution of the surface charge can be accurately quantified. We calibrated the chip in a three-electrode configuration and demonstrated the validity of the chip for rapid surface charge mapping using a borosilicate glass slide. This chip offers noninvasive, rapid mapping of surface charges on charged surfaces, with no need for physical or chemical modifications, and has broad potential applications in biomedical research and advanced material design.
Collapse
Affiliation(s)
- Leixin Ouyang
- Department of Mechanical Engineering, University of Akron, Akron, OH 44325, USA; (L.O.); (H.C.); (R.X.)
| | - Heyi Chen
- Department of Mechanical Engineering, University of Akron, Akron, OH 44325, USA; (L.O.); (H.C.); (R.X.)
| | - Ruiting Xu
- Department of Mechanical Engineering, University of Akron, Akron, OH 44325, USA; (L.O.); (H.C.); (R.X.)
| | - Rubia Shaik
- Department of Biomedical Engineering, University of Akron, Akron, OH 44325, USA; (R.S.); (G.Z.)
| | - Ge Zhang
- Department of Biomedical Engineering, University of Akron, Akron, OH 44325, USA; (R.S.); (G.Z.)
| | - Jiang Zhe
- Department of Mechanical Engineering, University of Akron, Akron, OH 44325, USA; (L.O.); (H.C.); (R.X.)
| |
Collapse
|
2
|
Feyzioglu BS, Avul Z. Effects of sperm separation methods before intrauterine insemination on pregnancy outcomes and live birth rates: Differences between the swim-up and microfluidic chip techniques. Medicine (Baltimore) 2023; 102:e36042. [PMID: 37986402 PMCID: PMC10659718 DOI: 10.1097/md.0000000000036042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 10/16/2023] [Accepted: 10/19/2023] [Indexed: 11/22/2023] Open
Abstract
Various sperm preparation techniques have been developed to obtain functionally, genetically and morphologically high-quality competent spermatozoa for use in assisted reproductive technologies, which may affect treatment options and thus pregnancy outcomes and live birth rates. We aimed to compare swim-up washing procedure (SWP) and microfluidics sperm sorting (MSS) with regard to sperm separation, pregnancy outcomes and live birth rates in infertile couples receiving intrauterine insemination. A total of 326 couples with unexplained infertility who underwent intrauterine insemination were enrolled in this retrospective cohort study and were divided into 2 groups according to sperm preparation technique. The MSS and SWP methods were used to prepare sperm in 178 and 148 patients, respectively. The median sperm concentration reduced significantly from 51 (30-100) million/mL to 20 (10-40) million/mL in the MSS group, and from 45 (26-80) million/mL to 25 (11-48) million/mL in the SWP group (both P < .001). Median motility increased significantly from 30.43 ± 17.79 to 57.48 ± 20.24 in the MSS, and from 32.89 ± 13.92 to 43.91 ± 20.11 in SWP (both P < .001). There was a difference between groups after preparation regarding sperm concentration (better with SWP) and motility (better with MSS) (P = .018 and P < .001, respectively). A total of 86 (26.4%) pregnancies were observed in participants and the clinical pregnancy rate was 23% in the MSS group and 30.4% in the SWP group (P = .133). Fifty-one infants were born alive and a great majority (n = 47) were delivered at term. Multivariate logistic regression analysis showed that higher duration of infertility was independently associated with lower live birth success (odds ratio: 0.811, 95% confidence interval: 0.662-0.996; P = .045). Other variables, including female age, type and reason of infertility, number of cycles, and sperm motility and concentration, were found to be nonsignificant (P > .05). We observed nonsignificant worse reproductive results using microfluid sperm selection in comparison to the pellet swim-up technique (live birth rate = 12% vs 20%). Our evidence is of limited quality due to the retrospective design of this study and sufficiently powered RCTs are needed to evaluate whether sperm selection based using a microfluidic chip is better, similar, or worse than the pellet swim-up technique.
Collapse
Affiliation(s)
- Bihter Senem Feyzioglu
- Department of Obstetrics and Gynecology, Private Erciyes-Kartal Hospital, Kayseri, Turkey
| | - Zerrin Avul
- Department of Obstetrics and Gynecology, Private Erciyes-Kartal Hospital, Kayseri, Turkey
| |
Collapse
|
3
|
Ardila CM, Jiménez-Arbeláez GA, Vivares-Builes AM. A Systematic Review of In Vitro Studies Using Microchip Platforms for Identifying Periodontopathogens from the Red Complex. Dent J (Basel) 2023; 11:245. [PMID: 37999009 PMCID: PMC10670886 DOI: 10.3390/dj11110245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/06/2023] [Accepted: 10/20/2023] [Indexed: 11/25/2023] Open
Abstract
Porphyromonas gingivalis, Tannerella forsythia, and Treponema denticola, collectively recognized as periodontopathogens within the red complex, have been extensively studied in clinical samples collected from individuals with periodontitis. A lab-on-a-chip (LOC) is a miniature mechanism that integrates various laboratory operations onto a single microchip or a small-scale platform. This systematic review evaluates the application of LOC technology in identifying microorganisms from the red complex. This study adhered to PRISMA recommendations, and the review process encompassed several databases. In the electronic search, a total of 58 reports were found, and ultimately, 10 studies were considered relevant for inclusion. All these studies described effective, rapid, and reliable LOC systems for detecting and amplifying P. gingivalis, T. forsythia, and T. denticola. Compared to traditional methods, the LOC approach demonstrated minimal reagent requirements. Additionally, the results indicated that the amplification process took approximately 2 to 8 min, while detection could be completed in as little as 2 min and 40 s, resulting in a total experimental duration of around 11 min. Integrating miniaturization, speed, accuracy, and automation within microchip platforms makes them promising tools for detecting and amplifying microorganisms associated with the red complex in periodontal diseases.
Collapse
Affiliation(s)
- Carlos M. Ardila
- Basic Studies Department, School of Dentistry, Universidad de Antioquia UdeA, Medellín 050010, Colombia
| | - Gustavo A. Jiménez-Arbeláez
- School of Dentistry, Institución Universitaria Visión de Las Américas, Medellín 050031, Colombia; (G.A.J.-A.); (A.M.V.-B.)
| | - Annie Marcela Vivares-Builes
- School of Dentistry, Institución Universitaria Visión de Las Américas, Medellín 050031, Colombia; (G.A.J.-A.); (A.M.V.-B.)
| |
Collapse
|
4
|
Ardila CM, Zuluaga-Gómez M, Vivares-Builes AM. Applications of Lab on a Chip in Antimicrobial Susceptibility of Staphylococcus aureus: A Systematic Review. Medicina (Kaunas) 2023; 59:1719. [PMID: 37893437 PMCID: PMC10608121 DOI: 10.3390/medicina59101719] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 09/23/2023] [Accepted: 09/25/2023] [Indexed: 10/29/2023]
Abstract
Background and Objectives: Staphylococcus aureus is a prevalent bacterium capable of inducing various infections, including skin and soft tissue infections, bloodstream infections, pneumonia, and surgical site infections. The emergence of antimicrobial resistance in S. aureus, particularly methicillin-resistant S. aureus, has raised substantial concerns within global healthcare settings. Prior to antibiotic prescription, the ideal approach is antimicrobial susceptibility testing (AST); however, this is frequently perceived as excessively complex and time-intensive. Lab-on-a-chip (LOC) technology holds promise in addressing these challenges and advancing fundamental microbiological research while also aiding in the development of therapeutic strategies. This systematic review aims to evaluate the potential utility of LOC for AST of S. aureus. Materials and Methods: This study adhered to the PRISMA guidelines. Various databases, including SCOPUS, PubMed/MEDLINE, SCIELO, and LILACS, in addition to gray literature sources, were employed in the review process. Results: Sixteen studies were included in this systematic review. All these studies detailed the effectiveness, rapidity, and predictability of LOC systems for assessing S. aureus susceptibility to various antibiotics. When comparing the LOC approach to traditional manual methods, it was evident that LOC requires a minimal quantity of reagents. Furthermore, most studies reported that the entire LOC procedure took 10 min to 7 h, with results being equally accurate as those obtained through traditional AST protocols. Conclusions: The potential application of LOC for AST of S. aureus is emphasized by its ability to provide rapid access to minimum inhibitory concentration data, which can substantially aid in selecting the most suitable antibiotics and dosages for treating challenging infections caused by this microorganism. Moreover, the rapid AST facilitated by LOC holds promise for enhancing the appropriateness and efficacy of therapy in clinical settings.
Collapse
Affiliation(s)
- Carlos M. Ardila
- Basic Studies Department, School of Dentistry, Universidad de Antioquia UdeA, Medellín 050010, Colombia
| | - Mateo Zuluaga-Gómez
- Emergency Department, Universidad Pontificia Bolivariana, Medellín 050010, Colombia;
- Hospital San Vicente Fundación, Rionegro 054047, Colombia
| | | |
Collapse
|
5
|
Zhang X, Zhou Y, Chen Y, Li M, Yu H, Li X. Advanced In Situ TEM Microchip with Excellent Temperature Uniformity and High Spatial Resolution. Sensors (Basel) 2023; 23:s23094470. [PMID: 37177673 PMCID: PMC10181734 DOI: 10.3390/s23094470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 04/22/2023] [Accepted: 04/29/2023] [Indexed: 05/15/2023]
Abstract
Transmission electron microscopy (TEM) is a highly effective method for scientific research, providing comprehensive analysis and characterization. However, traditional TEM is limited to observing static material structures at room temperature within a high-vacuum environment. To address this limitation, a microchip was developed for in situ TEM characterization, enabling the real-time study of material structure evolution and chemical process mechanisms. This microchip, based on microelectromechanical System (MEMS) technology, is capable of introducing multi-physics stimulation and can be used in conjunction with TEM to investigate the dynamic changes of matter in gas and high-temperature environments. The microchip design ensures a high-temperature uniformity in the sample observation area, and a system of tests was established to verify its performance. Results show that the temperature uniformity of 10 real-time observation windows with a total area of up to 1130 μm2 exceeded 95%, and the spatial resolution reached the lattice level, even in a flowing atmosphere of 1 bar.
Collapse
Affiliation(s)
- Xuelin Zhang
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
- School of Microelectronics, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yufan Zhou
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
- School of Microelectronics, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ying Chen
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
- School of Microelectronics, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ming Li
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
- School of Microelectronics, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Haitao Yu
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
- School of Microelectronics, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xinxin Li
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
- School of Microelectronics, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
6
|
Qi M, Ruan M, Liang J, Zhang Z, Chen C, Cao Y, He R. Three-Dimensional PLGA Nanofiber-Based Microchip for High-Efficiency Cancer Cell Capture. Materials (Basel) 2023; 16:3065. [PMID: 37109900 PMCID: PMC10144435 DOI: 10.3390/ma16083065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 04/07/2023] [Accepted: 04/11/2023] [Indexed: 06/19/2023]
Abstract
A 3D network capture substrate based on poly(lactic-co-glycolic acid) (PLGA) nanofibers was studied and successfully used for high-efficiency cancer cell capture. The arc-shaped glass micropillars were prepared by chemical wet etching and soft lithography. PLGA nanofibers were coupled with micropillars by electrospinning. Given the size effect of the microcolumn and PLGA nanofibers, a three-dimensional of micro-nanometer spatial network was prepared to form a network cell trapping substrate. After the modification of a specific anti-EpCAM antibody, MCF-7 cancer cells were captured successfully with a capture efficiency of 91%. Compared with the substrate composed of 2D nanofibers or nanoparticles, the developed 3D structure based on microcolumns and nanofibers had a greater contact probability between cells and the capture substrate, leading to a high capture efficiency. Cell capture based on this method can provide technical support for rare cells in peripheral blood detection, such as circulating tumor cells and circulating fetal nucleated red cells.
Collapse
|
7
|
Tavari T, Meamardoost S, Sepehry N, Akbarzadeh P, Nazari M, Hashemi NN, Nazari M. Effects of 3D electrodes arrangement in a novel AC electroosmotic micropump: Numerical modeling and experimental validation. Electrophoresis 2023; 44:450-461. [PMID: 36448415 DOI: 10.1002/elps.202200215] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 11/07/2022] [Accepted: 11/16/2022] [Indexed: 12/03/2022]
Abstract
To date, a comprehensive systematic optimization framework, capable of accurately predicting an efficient electrode geometry, is not available. Here, different geometries, including 3D step electrodes, have been designed in order to fabricate AC electroosmosis micropumps. It is essential to optimize both geometrical parameters of electrode, such as width and height of steps on each base electrode and their location in one pair, the size of each base electrode (symmetric or asymmetric), the gap of electrode pairs, and nongeometrical parameters such as fluid flow in a channel and electrical characteristics (e.g., frequency and voltage). The governing equations comprising of electric domain and fluid domain have been coupled using finite element method. The developed model was employed to investigate the effect of electrode geometric parameters on electroosmotic slip velocity and its subsequent effect on pressure and flow rate. Numerical simulation indicates that the optimal performance can be achieved using a design with varying step height and displacement, at a given voltage (2.5 V) and frequency (1 kHz). Finally, in order to validate the numerical simulation, the optimal microchip was fabricated using a combination of photolithography, electroplating, and a polydimethylsiloxane microchannel. Our results indicate that our micropump is capable of generating a pressure, velocity, and flow rate of 74.2 Pa, 1.76 mm/s, and 14.8 µl/min, respectively. This result reveals that our proposed geometry outperforms the state-of-the-art micropumps previously reported in the literature by improving the fluid velocity by 32%, with 80% less electrodes per unit length, and whereas the channel length is ∼80% shorter.
Collapse
Affiliation(s)
- Tannaz Tavari
- Department of Mechanical and Mechatronics Engineering, Shahrood University of Technology, Shahrood, Iran
| | - Saber Meamardoost
- Department of Chemical and Biological Engineering, University at Buffalo, Buffalo, New York, USA
| | - Naserodin Sepehry
- Department of Mechanical and Mechatronics Engineering, Shahrood University of Technology, Shahrood, Iran
| | - Pooria Akbarzadeh
- Department of Mechanical and Mechatronics Engineering, Shahrood University of Technology, Shahrood, Iran
| | - Mostafa Nazari
- Department of Mechanical and Mechatronics Engineering, Shahrood University of Technology, Shahrood, Iran
| | - Nicole N Hashemi
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa, USA
| | - Mohsen Nazari
- Department of Mechanical and Mechatronics Engineering, Shahrood University of Technology, Shahrood, Iran
| |
Collapse
|
8
|
HAMABE L, SHIMADA K, HIROSE M, YOSHIDA T, TAKEUCHI A, UEHARA K, TANAKA R. Preliminary report of spinal cord injuries resulting from inappropriate microchip implantation in two puppies. J Vet Med Sci 2023; 85:14-18. [PMID: 36351593 PMCID: PMC9887216 DOI: 10.1292/jvms.22-0344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Since the revised Animal Welfare and Management Law in Japan became effective on June 1st, 2022, it became mandatory for pet dogs and cats to have microchips implanted and registered prior to be sold. Two cases of spinal cord injury as the result of inappropriate microchip implantation in puppies were referred to our facility, of which were diagnosed by cervical spinal radiography and computed tomography (CT). While adverse reactions following microchip implantation are rare, the possibility of iatrogenic spinal cord injury remains a serious complication. This is the first report of adverse reactions following microchip implantation in Japan, and it alerts the possibility of iatrogenic spinal cord injury secondary to inappropriate microchip implantation, where adequate training and extra caution is crucial especially in small light-weight animals.
Collapse
Affiliation(s)
- Lina HAMABE
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Kazumi SHIMADA
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Tokyo, Japan,Correspondence to: Shimada K: , Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu, Tokyo 183-8509, Japan
| | - Miki HIROSE
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Tomohiko YOSHIDA
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Aki TAKEUCHI
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | | | - Ryou TANAKA
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Tokyo, Japan
| |
Collapse
|
9
|
Naghdi E, Moran GE, Reinau ME, De Malsche W, Neusüß C. Concepts and recent advances in microchip electrophoresis coupled to mass spectrometry: Technologies and applications. Electrophoresis 2023; 44:246-267. [PMID: 35977423 DOI: 10.1002/elps.202200179] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 08/11/2022] [Accepted: 08/13/2022] [Indexed: 02/01/2023]
Abstract
The online coupling of microchip electrophoresis (ME) as a fast, highly efficient, and low-cost miniaturized separation technique to mass spectrometry (MS) as an information-rich and sensitive characterization technique results in ME-MS an attractive tool for various applications. In this paper, we review the basic concepts and latest advances in technology for ME coupled to MS during the period of 2016-2021, covering microchip materials, structures, fabrication techniques, and interfacing to electrospray ionization (ESI)-MS and matrix-assisted laser desorption/ionization-MS. Two critical issues in coupling ME and ESI-MS include the electrical connection used to define the electrophoretic field strength along the separation channel and the generation of the electrospray for MS detection, as well as, a miniaturized ESI-tip. The recent commercialization of ME-MS in zone electrophoresis and isoelectric focusing modes has led to the widespread application of these techniques in academia and industry. Here we summarize recent applications of ME-MS for the separation and detection of antibodies, proteins, peptides, carbohydrates, metabolites, and so on. Throughout the paper these applications are discussed in the context of benefits and limitations of ME-MS in comparison to alternative techniques.
Collapse
Affiliation(s)
- Elahe Naghdi
- Department of Chemistry, Aalen University, Aalen, Germany
| | - Griffin E Moran
- Novo Nordisk A/S, Global Research Technologies, Maaloev, Denmark
| | | | - Wim De Malsche
- µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | | |
Collapse
|
10
|
Steward SK, McKee HM, Watson AM, Salman MD, Hassel DM. Transcutaneous Detection of Intramural Microchips for Tracking the Migration of the Equine Large Colon: A Pilot Study. Animals (Basel) 2022; 12. [PMID: 36496942 DOI: 10.3390/ani12233421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 11/27/2022] [Accepted: 12/02/2022] [Indexed: 12/12/2022] Open
Abstract
Colic remains the number one cause of mortality in horses, and large colon displacement including colonic volvulus is one of the leading causes for equine hospitalization and surgery. Currently, there is not an adequate model to study the pathophysiology of this condition. The objective of this proof-of-concept study was to determine if subserosal implantation of bioinert microchips in the large intestine would be detectable by a RFID (radio-frequency identification) receiver when the implanted microchips were adjacent to the body wall, thus identifying the location of the colon within the abdomen. A horse with no history of gastrointestinal disease underwent a ventral midline celiotomy to implant twelve bioinert microchips into the subserosa at predetermined locations within the large colon and cecum. A RFID scanner was used to monitor the location of the colon via transcutaneous identification 1-3 times daily for a one-month period. Following humane euthanasia, a postmortem examination of the horse was performed to assess microchip implantation sites for migration and histologic assessment. Eleven out of the 12 implanted microchips were successfully identified transcutaneously at occurrences as high as 100%. Odds ratios were calculated for the likelihood of identifying each chip in a location different from its most common location. Microchips implanted into the subserosa of the equine large colon can be used as a means of identifying the approximate location of the equine large colon via transcutaneous identification with an RFID scanner.
Collapse
|
11
|
Abstract
INTRODUCTION Electronically powered drug delivery devices enable a controlled drug release route for a more convenient and painless way with reduced side effects. The current advances in microfabrication and microelectronics have facilitated miniaturization and intelligence with the integration of sensors and wireless communication modules. These devices have become an essential component of commercialized on-demand drug delivery. AREAS COVERED This review aims to provide a concise overview of current progress in electronically powered drug devices, focusing on delivery strategies, manufacturing techniques, and control circuit design with specific examples. EXPERT OPINION The application of electronically powered drug delivery systems is now considered a feasible therapeutic approach with improved drug release efficiency and increased patient comfort. It is anticipated that these technologies will gradually fulfill clinical needs and resolve commercialization challenges in the future. This review discusses the current advances in electronic drug delivery devices, especially focusing on designing strategies to achieve an effective drug release, as well as the perspectives and challenges for future applications in clinical therapy.
Collapse
Affiliation(s)
- Guang Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, P. R. China
| | - Yanli Lu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, P. R. China
| | - Fenni Zhang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, P. R. China
| | - Qingjun Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, P. R. China
| |
Collapse
|
12
|
McMurrer J, McElhiney A, McNally K, Innis CJ. Observations on the use of passive integrated transponder (PIT) tags in teleosts and elasmobranchs at a public aquarium, 728 cases, 2007-2020. Zoo Biol 2022; 41:576-581. [PMID: 35037285 DOI: 10.1002/zoo.21678] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 12/10/2021] [Accepted: 01/04/2022] [Indexed: 12/16/2022]
Abstract
Between 2007 and 2020 at New England Aquarium, Boston, MA, USA, we implanted passive integrated transponder (PIT) tags into 728 fish representing 105 teleost and elasmobranch species to identify animals as individuals. At the time of retrospective data analysis, mean longevity interval (median, range) after tag placement for animals that remained alive (n = 236) was 4.7 years (4.5, 0.3-13.8). Mean interval (median, range) between tag placement and death (n = 317) was 2.1 years (1.6, 0-11.2); and mean interval (median, range) between tag placement and transfer to other facilities (n = 175) was 2.5 years (3.1, 0.1-9.3). Possible adverse effects of tagging were extremely rare. Using the described methods, the equipment cost for every 10 PIT tag implantations was $2.83. PIT tag implantation in fishes is a safe and cost effective method to identify individuals, providing an opportunity to accumulate valuable data regarding individual longevity, welfare, basic demographics, and outcome of medical management. PIT tag implantation is recommended as a routine aspect of acquisition, quarantine, and medical management of fish under human care.
Collapse
Affiliation(s)
- Jessica McMurrer
- Animal Health Department, New England Aquarium, Central Wharf, Boston, Massachusetts, USA
| | - Aubrey McElhiney
- Animal Health Department, New England Aquarium, Central Wharf, Boston, Massachusetts, USA
| | - Kerry McNally
- Animal Health Department, New England Aquarium, Central Wharf, Boston, Massachusetts, USA
| | - Charles J Innis
- Animal Health Department, New England Aquarium, Central Wharf, Boston, Massachusetts, USA
| |
Collapse
|
13
|
Shimizu I, Yamashita K, Tokunaga E. Development of a Simple Fabrication Method for Magnetic Micro Stir Bars and Induction of Rotational Motion in Chlamydomonas reinhardtii. Micromachines (Basel) 2022; 13:1842. [PMID: 36363863 PMCID: PMC9695637 DOI: 10.3390/mi13111842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/16/2022] [Accepted: 10/25/2022] [Indexed: 06/16/2023]
Abstract
A magnetic micro stirrer bar (MMSB) is used in the mixing operation of microfluidic devices. We have established a low-cost and easy method to make MMSBs using magnetic (neodymium magnets, magnet sheets) or non-magnetic powders (SUS304) as materials. We demonstrated three kinds of MMSB have respective advantages. To confirm the practical use of this MMSB, a cell suspension of the motile unicellular green alga Chlamydomonas reinhardtii was stirred in microwells. As a result, the number of rotating cells increased with only one of the two flagella mechanically removed by the shear force of the rotating bar, which facilitates the kinetic analysis of the flagellar motion of the cell. The rotational motion of the monoflagellate cell was modeled as translational (orbital) + spinning motion of a sphere in a viscous fluid and the driving force per flagellum was confirmed to be consistent with previous literature. Since the present method does not use genetic manipulations or chemicals to remove a flagellum, it is possible to obtain cells in a more naturally viable state quickly and easily than before. However, since the components eluted from the powder material harm the health of cells, it was suggested that MMSB coated with resin for long-term use would be suitable for more diverse applications.
Collapse
|
14
|
Guler C, Melil S, Ozekici U, Donmez Cakil Y, Selam B, Cincik M. Sperm Selection and Embryo Development: A Comparison of the Density Gradient Centrifugation and Microfluidic Chip Sperm Preparation Methods in Patients with Astheno-Teratozoospermia. Life (Basel) 2021; 11:933. [PMID: 34575082 DOI: 10.3390/life11090933] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 09/02/2021] [Accepted: 09/04/2021] [Indexed: 11/28/2022] Open
Abstract
In recent years, microfluidic chip-based sperm sorting has emerged as an alternative tool to centrifugation-based conventional techniques for in vitro fertilization. This prospective study aims to compare the effects of density gradient centrifugation and microfluidic chip sperm preparation methods on embryo development in patient populations with astheno-teratozoospermia. In the study, the semen samples of the patients were divided into two groups for preparation with either the microfluidic or density gradient methods. Selected spermatozoa were then used to fertilize mature sibling oocytes and the semen parameters and embryo development on days 3 and 5 were assessed. While the density gradient group was associated with a higher sperm concentration, motility (progressive and total) was significantly higher in the microfluidic chip group. No significant differences were observed in the fertilization rates or grade 1 (G1) and grade 2 (G2) proportions of the third-day embryos. Furthermore, while the proportions of the poor, fair and good blastocysts on day 5 did not differ significantly, excellent blastocysts (indicating high-quality embryos) were observed in a significantly higher proportion of the microfluidic chip group. When compared to the classical density gradient method, the microfluidic chip sperm preparation yielded sperm with higher motility and higher quality blastocysts at day 5; in patients with astheno-teratozoospermia.
Collapse
|
15
|
Li X, Mitsuishi K, Takeguchi M. Fabrication of a liquid cell for in situ transmission electron microscopy. Microscopy (Oxf) 2021; 70:327-332. [PMID: 33320203 DOI: 10.1093/jmicro/dfaa076] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 11/26/2020] [Accepted: 12/15/2020] [Indexed: 11/13/2022] Open
Abstract
Liquid cell transmission electron microscopy (LCTEM) enables imaging of dynamic processes in liquid with high spatial and temporal resolution. The widely used liquid cell (LC) consists of two stacking microchips with a thin wet sample sandwiched between them. The vertically overlapped electron-transparent membrane windows on the microchips provide passage for the electron beam. However, microchips with imprecise dimensions usually cause poor alignment of the windows and difficulty in acquiring high-quality images. In this study, we developed a new and efficient microchip fabrication process for LCTEM with a large viewing area (180 µm × 40 µm) and evaluated the resultant LC. The new positioning reference marks on the surface of the Si wafer dramatically improve the precision of dicing the wafer, making it possible to accurately align the windows on two stacking microchips. The precise alignment led to a liquid thickness of 125.6 nm close to the edge of the viewing area. The performance of our LC was demonstrated by in situ transmission electron microscopy imaging of the dynamic motions of 2-nm Pt particles. This versatile and cost-effective microchip production method can be used to fabricate other types of microchips for in situ electron microscopy.
Collapse
Affiliation(s)
| | - Kazutaka Mitsuishi
- Transmission Electron Microscopy Analysis Station, National Institute for Materials Science (NIMS), Sengen 1-2-1, Tsukuba, Ibaraki 305-0047, Japan
| | | |
Collapse
|
16
|
Xu H, Wu Z, Deng J, Qiu J, Hu N, Gao L, Yang J. Microsphere-Based Microfluidic Device for Plasma Separation and Potential Biochemistry Analysis Applications. Micromachines (Basel) 2021; 12:mi12050487. [PMID: 33925769 PMCID: PMC8144965 DOI: 10.3390/mi12050487] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 04/13/2021] [Accepted: 04/21/2021] [Indexed: 11/29/2022]
Abstract
The development of a simple, portable, and cost-effective plasma separation platform for blood biochemical analysis is of great interest in clinical diagnostics. We represent a plasma separation microfluidic device using microspheres with different sizes as the separation barrier. This plasma separation device, with 18 capillary microchannels, can extract about 3 μL of plasma from a 50 μL blood sample in about 55 min. The effects of evaporation and the microsphere barrier on the plasma biochemical analysis results were studied. Correction factors were applied to compensate for these two effects. The feasibility of the device in plasma biochemical analysis was validated with clinical blood samples.
Collapse
Affiliation(s)
- Hongyan Xu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400030, China; (H.X.); (Z.W.); (J.D.); (N.H.)
| | - Zhangying Wu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400030, China; (H.X.); (Z.W.); (J.D.); (N.H.)
| | - Jinan Deng
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400030, China; (H.X.); (Z.W.); (J.D.); (N.H.)
| | - Jun Qiu
- Department of Information, First Affiliated Hospital, Army Medical University, Chongqing 400042, China
- Correspondence: (J.Q.); (L.G.); (J.Y.); Tel.: +86-23-6875-4443 (J.Q.); +86-23-6035-3856 (L.G.); +86-23-6510-2291 (J.Y.)
| | - Ning Hu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400030, China; (H.X.); (Z.W.); (J.D.); (N.H.)
| | - Lihong Gao
- Chongqing Center for Drug Evaluation and Certification, Chongqing 401120, China
- Correspondence: (J.Q.); (L.G.); (J.Y.); Tel.: +86-23-6875-4443 (J.Q.); +86-23-6035-3856 (L.G.); +86-23-6510-2291 (J.Y.)
| | - Jun Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400030, China; (H.X.); (Z.W.); (J.D.); (N.H.)
- Correspondence: (J.Q.); (L.G.); (J.Y.); Tel.: +86-23-6875-4443 (J.Q.); +86-23-6035-3856 (L.G.); +86-23-6510-2291 (J.Y.)
| |
Collapse
|
17
|
Chen Z, Wang F, Zhang J, Sun X, Yan Y, Wang Y, Ouyang J, Zhang J, Honore T, Ge J, Gu Z. Study on Development of Composite Hydrogels With Tunable Structures and Properties for Tumor-on-a-Chip Research. Front Bioeng Biotechnol 2020; 8:611796. [PMID: 33425875 PMCID: PMC7786431 DOI: 10.3389/fbioe.2020.611796] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 11/10/2020] [Indexed: 11/13/2022] Open
Abstract
A major factor for developing new tumor models is to recreate a proper three-dimensional environment for 3D tumors culture. In this 3D microenvironment, extracellular matrices play important roles in regulation of hallmark features of cancer through biochemical and mechanical signals. The fabrication of a mechanical and biophysical controllable hydrogel, while sharing similarities with Matrigel in cancer invasiveness evaluation, is an urgent but unmet need. In this study, we developed a hybrid hydrogel system composed of GelMA and hydrolyzed collagen to model tumor micro-environment and tested with several cancer cells with different origin and characteristics. This hydrogel possesses a well-ordered homogenous microstructure, excellent permeability and an adjustable mechanical stiffness. This hydrogel demonstrated similar properties as Matrigel in tumor spheroids culture and 3D tumor invasiveness studies. It was further applied in a Tumor-on-a-Chip system with 3D-bioprinting. Our research demonstrated this hydrogel's effectiveness in tumor 3D culture, and its potential to replace Matrigel in cancer invasiveness evaluation.
Collapse
Affiliation(s)
- Zaozao Chen
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Fei Wang
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Jie Zhang
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Xiaowei Sun
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Yuchuan Yan
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Yan Wang
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Jun Ouyang
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Jing Zhang
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Tess Honore
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Jianjun Ge
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Zhongze Gu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| |
Collapse
|
18
|
Abstract
The ability to comprehensively profile proteins in every individual cell of complex biological systems is crucial to advance our understanding of normal physiology and disease pathogenesis. Conventional bulk cell experiments mask the cell heterogeneity in the population, while the single-cell imaging methods suffer from the limited multiplexing capacities. Recent advances in microchip-, mass spectrometry-, and reiterative staining-based technologies have enabled comprehensive protein profiling in single cells. These approaches will bring new insights into a variety of biological and biomedical fields, such as signaling network regulation, cell heterogeneity, tissue architecture, disease diagnosis, and treatment monitoring. In this article, we will review the recent advances in the development of single-cell proteomic technologies, describe their advantages, discuss the current limitations and challenges, and propose potential solutions. We will also highlight the wide applications of these technologies in biology and medicine. This article is categorized under: Cancer > Molecular and Cellular Physiology.
Collapse
Affiliation(s)
- Thai Pham
- Biodesign Institute & School of Molecular Sciences, Arizona State University, Tempe, Arizona, USA
| | - Ankush Tyagi
- Biodesign Institute & School of Molecular Sciences, Arizona State University, Tempe, Arizona, USA
| | - Yu-Sheng Wang
- Biodesign Institute & School of Molecular Sciences, Arizona State University, Tempe, Arizona, USA
| | - Jia Guo
- Biodesign Institute & School of Molecular Sciences, Arizona State University, Tempe, Arizona, USA
| |
Collapse
|
19
|
An J, Jiang Y, Shi B, Wu D, Wu W. Low-Cost Battery-Powered and User-Friendly Real-Time Quantitative PCR System for the Detection of Multigene. Micromachines (Basel) 2020; 11:mi11040435. [PMID: 32326194 PMCID: PMC7231343 DOI: 10.3390/mi11040435] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 04/09/2020] [Accepted: 04/15/2020] [Indexed: 12/25/2022]
Abstract
Real-time polymerase chain reaction (PCR) is the standard for nucleic acid detection and plays an important role in many fields. A new chip design is proposed in this study to avoid the use of expensive instruments for hydrophobic treatment of the surface, and a new injection method solves the issue of bubbles formed during the temperature cycle. We built a battery-powered real-time PCR device to follow polymerase chain reaction using fluorescence detection and developed an independently designed electromechanical control system and a fluorescence analysis software to control the temperature cycle, the photoelectric detection coupling, and the automatic analysis of the experimental data. The microchips and the temperature cycling system cost USD 100. All the elements of the device are available through open access, and there are no technical barriers. The simple structure and manipulation allows beginners to build instruments and perform PCR tests after only a short tutorial. The device is used for analysis of the amplification curve and the melting curve of multiple target genes to demonstrate that our instrument has the same accuracy and stability as a commercial instrument.
Collapse
Affiliation(s)
- Junru An
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China; (J.A.); (Y.J.); (B.S.); (D.W.)
- University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
| | - Yangyang Jiang
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China; (J.A.); (Y.J.); (B.S.); (D.W.)
| | - Bing Shi
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China; (J.A.); (Y.J.); (B.S.); (D.W.)
- University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
| | - Di Wu
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China; (J.A.); (Y.J.); (B.S.); (D.W.)
- University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
| | - Wenming Wu
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China; (J.A.); (Y.J.); (B.S.); (D.W.)
- University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
- Correspondence: ; Tel.: +86-431-8670-8159
| |
Collapse
|
20
|
Hao N, Zhang M, Zhang JXJ. Microfluidics for ZnO micro-/nanomaterials development: rational design, controllable synthesis, and on-chip bioapplications. Biomater Sci 2020; 8:1783-1801. [PMID: 31965125 PMCID: PMC7768907 DOI: 10.1039/c9bm01787a] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Zinc oxide (ZnO) materials hold great promise in diverse applications due to their attractive physicochemical features. Recent years, especially the last decade, have witnessed considerable progress toward rational design and bioapplications of multiscale ZnO materials through microfluidic techniques. Design of a microfluidic device that allows for precise control over reaction conditions could not only yield ZnO particles with a fast production rate and high quality, but also permit downstream applications with desirable and superior performance. This review summarizes microfluidic approaches for the synthesis and applications of ZnO micro-/nanomaterials. In particular, we discuss the recent achievement of using microfluidic reactors in the controllable synthesis of ZnO structures (wire, rod, sphere, flower, sheet, flake, spindle, and ellipsoid), and highlight the unprecedented opportunities for applying them in biosensing, biological separation, and molecular catalysis applications through microfluidic chips. Finally, major challenges and potential opportunities are explored to guide future studies in this area.
Collapse
Affiliation(s)
- Nanjing Hao
- Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, New Hampshire 03755, USA.
| | - Michael Zhang
- The Lawrenceville School, 2500 Main St, Lawrenceville, New Jersey 08648, USA
| | - John X J Zhang
- Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, New Hampshire 03755, USA.
| |
Collapse
|
21
|
Chang S, Kim S, Han J, Ha S, Lee H, Song SW, Lee D, Kwon S, Chung J, Kim J. A High-Throughput Single-Clone Phage Fluorescence Microwell Immunoassay and Laser-Driven Clonal Retrieval System. Biomolecules 2020; 10:E517. [PMID: 32235304 DOI: 10.3390/biom10040517] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Accepted: 03/26/2020] [Indexed: 12/03/2022] Open
Abstract
Phage display is one of the most frequently used platform technologies utilized to screen and select therapeutic antibodies, and has contributed to the development of more than 10 therapeutic antibodies used in the clinic. Despite advantages like efficiency and low cost, it has intrinsic technical limitations, such as the asymmetrical amplification of the library after each round of biopanning, which is regarded as a reason for it yielding a very limited number of antigen binders. In this study, we developed a high-throughput single-clonal screening system comprised of fluorescence immunoassays and a laser-driven clonal DNA retrieval system using microchip technology. Using this system, from a single-chain variable fragment (scFv) library displayed on phages with a complexity of 5.21 × 105 harboring random mutations at five amino acid residues, more than 70,000 clones—corresponding to ~14% of the library complexity—were screened, resulting in 78 antigen-reactive scFv sequences with mutations restricted to the randomized residues. Our results demonstrate that this system can significantly reduce the number of biopanning rounds, or even eliminate the need for this process for libraries with lower complexity, providing an opportunity to obtain more diverse clones from the library.
Collapse
|
22
|
Li Y, Wang J, Wan W, Chen C, Wang X, Zhao P, Hou Y, Tian H, Wang J, Nandakumar K, Wang L. Engineering a Bi-Conical Microchip as Vascular Stenosis Model. Micromachines (Basel) 2019; 10:E790. [PMID: 31752172 DOI: 10.3390/mi10110790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 11/10/2019] [Accepted: 11/14/2019] [Indexed: 11/17/2022]
Abstract
Vascular stenosis is always associated with hemodynamic changes, especially shear stress alterations. Herein, bi-conical shaped microvessels were developed through flexibly and precisely controlled templated methods for hydrogel blood-vessel-like microchip. The blood-vessel-like microvessels demonstrated tunable dimensions, perfusable ability, and good cytocompatibility. The microchips showed blood-vessel-like lumens through fine embeddedness of human umbilical vein endothelial cells (HUVECs) on the interior surface of hydrogel microchannels, which closely reproduced the morphology and functions of human blood vessels. In the gradual narrowing region of bi-conical shape, fluid flow generated wall shear stress, which caused cell morphology variations. Wall shear rates at the gradual narrowing region were simulated by FLUENT software. The results showed that our microchannels qualified for performance as a vascular stenosis-like model in evaluating blood hydrodynamics. In general, our blood-vessel-on-a-chip could offer potential applications in the prevention, diagnosis, and therapy of arterial thrombosis.
Collapse
|
23
|
van Harten E, Reardon T, Lumsden LF, Meyers N, Prowse TAA, Weyland J, Lawrence R. High detectability with low impact: Optimizing large PIT tracking systems for cave-dwelling bats. Ecol Evol 2019; 9:10916-10928. [PMID: 31641445 PMCID: PMC6802374 DOI: 10.1002/ece3.5482] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 07/02/2019] [Accepted: 07/05/2019] [Indexed: 11/09/2022] Open
Abstract
Passive integrated transponder (PIT) tag technology permits the "resighting" of animals tagged for ecological research without the need for physical re-trapping. Whilst this is effective if animals pass within centimeters of tag readers, short-distance detection capabilities have prevented the use of this technology with many species. To address this problem, we optimized a large (15 m long) flexible antenna system to provide a c. 8 m2 vertical detection plane for detecting animals in flight. We installed antennas at two roosting caves, including the primary maternity cave, of the critically endangered southern bent-winged bat (Miniopterus orianae bassanii) in south-eastern Australia. Testing of these systems indicated PIT-tags could be detected up to 105 cm either side of the antenna plane. Over the course of a three-year study, we subcutaneously PIT-tagged 2,966 bats and logged over 1.4 million unique detections, with 97% of tagged bats detected at least once. The probability of encountering a tagged bat decreased with increasing environmental "noise" (unwanted signal) perceived by the system. During the study, we mitigated initial high noise levels by earthing both systems, which contributed to an increase in daily detection probability (based on the proportion of individuals known to be alive that were detected each day) from <0.2 (noise level ≥30%) to 0.7-0.8 (noise level 5%-15%). Conditional on a low (5%) noise level, model-based estimates of daily encounter probability were highest (>0.8) during peak breeding season when both female and male southern bent-winged bats congregate at the maternity cave. In this paper, we detail the methods employed and make methodological recommendations for future wildlife research using large antennas, including earthing systems as standard protocol and quantifying noise metrics as a covariate influencing the probability of detection in subsequent analyses. Our results demonstrate that large PIT antennas can be used successfully to detect small volant species, extending the scope of PIT technology and enabling a much broader range of wildlife species to be studied using this approach.
Collapse
Affiliation(s)
- Emmi van Harten
- Department of Ecology, Environment and EvolutionLa Trobe UniversityBundooraVic.Australia
| | | | - Lindy F. Lumsden
- Department of Environment, Land, Water and PlanningArthur Rylah Institute for Environmental ResearchHeidelbergVic.Australia
| | | | - Thomas A. A. Prowse
- School of Mathematical SciencesThe University of AdelaideAdelaideSAAustralia
| | - John Weyland
- School of Natural and Built EnvironmentsUniversity of South AustraliaMawson LakesSAAustralia
| | | |
Collapse
|
24
|
Abstract
Cytokine production is often regarded as the marker of immune cells' activation status. The spectrum and temporal secretion of cytokines are dramatically varied between cell phenotypes and even within the same phenotype. Multiparameter analysis of individual immune cell's cytokine secretion has always been a challenging and complicated process that needs special facilities in a laboratory setting. Herein, we present an ultrasimple method with high sensitivity and high robustness to quantify cytokine expression at the single-cell resolution. A microchip is developed based on poly(dimethylsiloxane) nanowells on sticky tape, while each nanowell is integrated with a DNA-antibody convertible microarray. Only pipetting is needed for the whole single-cell analysis process. The sensitivity of the assay is evaluated by measuring various concentrations of six recombinant cytokine proteins, which was found comparable to conventional methods. Once single cells are loaded to nanowells and incubated there, a Fluorinert FC-40 is used to isolate nanowells; so, cytokines from those cells are captured by separate microarrays. The rest of the sandwich enzyme-linked immunosorbent assay detection process is also executed simply by pipetting of various reagents. This method is validated by measuring cytokine production from hundreds of single cells. It has simplified a typically sophisticated multiplex single-cell assay into an instrument-free, point-of-detection technology, and thus it may find a broad utility in clinical diagnostics.
Collapse
Affiliation(s)
- Mohammed A. A. Abdullah
- Multiplex Biotechnology Laboratory, Department of Chemistry, University at Albany, State University of New York, Albany, New York 12222, United States
| | - Jun Wang
- Multiplex Biotechnology Laboratory, Department of Chemistry, University at Albany, State University of New York, Albany, New York 12222, United States
- Cancer Research Center, University at Albany, State University of New York, Rensselaer, New York 12144, United States
| |
Collapse
|
25
|
McGreevy P, Masters S, Richards L, Soares Magalhaes RJ, Peaston A, Combs M, Irwin PJ, Lloyd J, Croton C, Wylie C, Wilson B. Identification of Microchip Implantation Events for Dogs and Cats in the VetCompass Australia Database. Animals (Basel) 2019; 9:E423. [PMID: 31284533 DOI: 10.3390/ani9070423] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Revised: 06/28/2019] [Accepted: 07/03/2019] [Indexed: 11/17/2022] Open
Abstract
Simple Summary The implantation of a microchip can maximise an animal’s chance of being returned to its owners, if separated, but is also a statutory requirement for companion animal owners in many jurisdictions across Australia. This study of the electronic patient records of 1000 randomly selected dogs and cats in the VetCompass Australia database revealed that the median age at microchip implantation was 74.4 days for individual dogs and 127.0 days for individual cats. Further exploration into the reasons for later microchipping in cats may be useful in aligning common practice with legislative requirements. Abstract In Australia, compulsory microchipping legislation requires that animals are microchipped before sale or prior to 3 months in the Australian Capital Territory, New South Wales, Queensland and Victoria, and by 6 months in Western Australia and Tasmania. Describing the implementation of microchipping in animals allows the data guardians to identify individual animals presenting to differing veterinary practices over their lifetimes, and to evaluate compliance with legislation. VetCompass Australia (VCA) collates electronic patient records from primary care veterinary practices into a database for epidemiological studies. VCA is the largest companion animal clinical data repository of its kind in Australia, and is therefore the ideal resource to analyse microchip data as a permanent unique identifier of an animal. The current study examined the free-text ‘examination record’ field in the electronic patient records of 1000 randomly selected dogs and cats in the VCA database. This field may allow identification of the date of microchip implantation, enabling comparison with other date fields in the database, such as date of birth. The study revealed that the median age at implantation for dogs presented as individual patients, rather than among litters, was 74.4 days, significantly lower than for cats (127.0 days, p = 0.003). Further exploration into reasons for later microchipping in cats may be useful in aligning common practice with legislative requirements.
Collapse
|
26
|
Luo M, Jiang Y, Su J, Deng Z, Mou F, Xu L, Guan J. Surface Charge-Reversible Tubular Micromotors for Extraction of Nucleic Acids in Microsystems. Chem Asian J 2019; 14:2503-2511. [PMID: 30997736 DOI: 10.1002/asia.201900427] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 04/16/2019] [Indexed: 12/13/2022]
Abstract
Extraction of nucleic acids in microsystems is of significance for biomedical applications, but the current extraction methods generally require sophisticated microchannels and external equipment, hindering their practical applications. In this work, we have demonstrated a simple, versatile and efficient approach to extract nucleic acids in microsystems by developing cationic branched polyethyleneimine (PEI)-functionalized tubular micromotors. The as-developed tubular micromotors are fabricated by a two-step process combining the template-assisted electrodeposition and carbodiimide chemistry, and contain an inner catalytic Pt layer, a middle magnetic Ni layer and an outer cationic PEI layer. They exhibit autonomous bubble-propelled motion in aqueous hydrogen peroxide solutions, which can be guided by an external magnetic field, and the surface charges can be reversibly modulated by changing the pH value of the solution. Consequently, the as-developed tubular micromotors can selectively absorb nucleic acids from acidic solutions and desorb them into alkaline solutions, leading to the extraction of nucleic acids with high efficiency without external stirring. Furthermore, they can be operated in a microchannel chip without the aid of a pumping system. Our results indicate that this PEI-functionalized tubular micromotor platform provides a novel, simple and versatile microsystem nucleic acid extraction technology, holding considerable promise for important practical applications.
Collapse
Affiliation(s)
- Ming Luo
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, International School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, P. R. China
| | - Yuzhou Jiang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, International School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, P. R. China
| | - Jingbei Su
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, International School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, P. R. China
| | - Zhuoyi Deng
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, International School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, P. R. China
| | - Fangzhi Mou
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, International School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, P. R. China
| | - Leilei Xu
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, International School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, P. R. China
| | - Jianguo Guan
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, International School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, P. R. China
| |
Collapse
|
27
|
Hong T, Lu A, Liu W, Chen C. Microdroplet Synthesis of Silver Nanoparticles with Controlled Sizes. Micromachines (Basel) 2019; 10:mi10040274. [PMID: 31022869 PMCID: PMC6523276 DOI: 10.3390/mi10040274] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 04/19/2019] [Accepted: 04/19/2019] [Indexed: 11/16/2022]
Abstract
A method was developed to synthesize silver nanoparticles with controlled size and Localized Surface Plasmon Resonance (LSPR) wavelength. In a microchip, droplets with high monodispersity and stability were produced. Using droplets as microreactors, seed-mediated growth approach was successfully applied for silver nanoparticles preparation. It was observed that nanoparticles size and LSPR wavelength could be optimized via adjusting synthesis conditions, such as droplets heating temperature, reaction time, and concentration of silver seeds and silver nitrate in aqueous phase. These results indicated that the proposed microdevices could provide a convenient and inexpensive approach for preparing nanoparticles with optimum properties.
Collapse
Affiliation(s)
- Tingting Hong
- School of Pharmaceutical Sciences, Central South University, Changsha 410013, China.
| | - Aijuan Lu
- Hunan Key Laboratory Cultivation Base of the Research and Development of Novel Pharmaceutical Preparations, Changsha 410219, China.
| | - Wenfang Liu
- School of Pharmaceutical Sciences, Central South University, Changsha 410013, China.
| | - Chuanpin Chen
- School of Pharmaceutical Sciences, Central South University, Changsha 410013, China.
| |
Collapse
|
28
|
Wu MA, Tsvirkun D, Bureau L, Boccon-Gibod I, Inglebert M, Duperray A, Bouillet L, Misbah C, Cicardi M. Paroxysmal Permeability Disorders: Development of a Microfluidic Device to Assess Endothelial Barrier Function. Front Med (Lausanne) 2019; 6:89. [PMID: 31069229 PMCID: PMC6491734 DOI: 10.3389/fmed.2019.00089] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Accepted: 04/09/2019] [Indexed: 11/28/2022] Open
Abstract
Background: Paroxysmal Permeability Disorders (PPDs) are pathological conditions caused by periodic short lasting increase of endothelial permeability, in the absence of inflammatory, degenerative, ischemic vascular injury. PPDs include primary angioedema, idiopathic systemic capillary leak syndrome and some rare forms of localized retroperitoneal-mediastinal edema. Aim: to validate a microfluidic device to study endothelial permeability in flow conditions. Materials and Methods: we designed a microchannel network (the smallest channel is 30μm square section). Human Umbilical Vein Endothelial Cells (HUVECs) were cultured under constant shear stress in the networks. Endothelial permeability assessment was based on interaction of biotinylated fibronectin used as a matrix for HUVECs and FITC-conjugated avidin. The increase in endothelial permeability was identified as changes in fluorescence intensity detected by confocal fluorescent microscopy. Results: The microchannels were constantly perfused with a steady flow of culture medium, ensuring a physiologically relevant level of shear stress at the wall of ~0.2 Pa. Our preliminary results demonstrated that circulation of culture medium or plasma from healthy volunteers was associated with low fluorescence of fibronectin matrix. When bradykinin diluted in culture medium was perfused, an increase in average fluorescence was detected. Conclusion: Our microvasculature model is suitable to study endothelial functions in physiological flow conditions and in the presence of factors like bradykinin known as mediator of several PPDs. Therefore, it can be a promising tool to better understand the mechanisms underlying disorders of endothelial permeability.
Collapse
Affiliation(s)
- Maddalena Alessandra Wu
- Department of Biomedical and Clinical Sciences, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, Milan, Italy
| | - Daria Tsvirkun
- Univ. Grenoble Alpes, LIPHY, Grenoble, France.,CNRS, LIPHY, Grenoble, France.,Belozersky Institute of Physico-chemical Biology, Lomonosov Moscow State University, Moscow, Russia
| | - Lionel Bureau
- Univ. Grenoble Alpes, LIPHY, Grenoble, France.,CNRS, LIPHY, Grenoble, France
| | - Isabelle Boccon-Gibod
- Department of Internal Medicine, Centre Hospitalier Universitaire de Grenoble, Grenoble, France
| | | | - Alain Duperray
- Univ. Grenoble Alpes, IAB, Grenoble, France.,INSERM, IAB, Grenoble, France
| | - Laurence Bouillet
- Department of Internal Medicine, Centre Hospitalier Universitaire de Grenoble, Grenoble, France
| | - Chaouqi Misbah
- Univ. Grenoble Alpes, LIPHY, Grenoble, France.,CNRS, LIPHY, Grenoble, France
| | - Marco Cicardi
- IRCCS-Istituti Clinici Scientifici Maugeri, University of Milan, Milan, Italy
| |
Collapse
|
29
|
Abstract
Single-cell omics studies provide unique information regarding cellular heterogeneity at various levels of the molecular biology central dogma. This knowledge facilitates a deeper understanding of how underlying molecular and architectural changes alter cell behavior, development, and disease processes. The emerging microchip-based tools for single-cell omics analysis are enabling the evaluation of cellular omics with high throughput, improved sensitivity, and reduced cost. We review state-of-the-art microchip platforms for profiling genomics, epigenomics, transcriptomics, proteomics, metabolomics, and multi-omics at single-cell resolution. We also discuss the background of and challenges in the analysis of each molecular layer and integration of multiple levels of omics data, as well as how microchip-based methodologies benefit these fields. Additionally, we examine the advantages and limitations of these approaches. Looking forward, we describe additional challenges and future opportunities that will facilitate the improvement and broad adoption of single-cell omics in life science and medicine.
Collapse
Affiliation(s)
- Yanxiang Deng
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut 06511, USA; , ,
| | - Amanda Finck
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut 06511, USA; , ,
| | - Rong Fan
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut 06511, USA; , ,
| |
Collapse
|
30
|
Abstract
Multiplex measurement of protein expression with the single-cell resolution has been challenging. Although a few conventional approaches including flow cytometry and immunofluorescence-based methods have been developed to detect proteins in individual cells, they are either dependent on bulky instrument or not multiplexed and high-throughput enough. Here we present a portable single-cell analysis system that is operable in a resource-limited environment. A stand-sit microchip housed in a clamp enables simple and instrument-free operation of all necessary steps, and the detection based on immunogold enhancement exonerates the reliance on fluorescence optics and electronics. The quantified sensitivity was found comparable to the conventional fluorescence approaches. We used this system to analyze five immune effector proteins and found the system is equally effective to detect those proteins in hundreds of single cells. Significant increase of cytokine protein production by THP1 monocytes was observed upon stimulation by lipopolysaccharide. Further study showed that a low-end imaging setup with low resolution can also detect signals without much loss of sensitivity. Taken together, this portable multiplex single-cell system may find broad biomedical applications in a field setting.
Collapse
Affiliation(s)
- Sirsendu Bhowmick
- Multiplex Biotechnology Laboratory, Department of Chemistry, University at Albany, State University of New York, Albany, New York 12222, United States
| | - Jun Wang
- Multiplex Biotechnology Laboratory, Department of Chemistry, University at Albany, State University of New York, Albany, New York 12222, United States
- Cancer Research Center, University at Albany, State University of New York, Rensselaer, New York 12144, United States
| |
Collapse
|
31
|
Abstract
The blood vessel is part of the circulatory system, and systemic circulation provides the blood supply to all tissues. Arteries are pathways through which the blood is carried, and the capillaries have a key role in material exchange to maintain the tissue environment. Blood vessels have structures appropriate for their functions, and their sizes and cell types are different. In this review, we introduced recent studies of the microfluidic vascular models. The model structures are classified mainly as poly(dimethylsiloxane) and hydrogel microchannels and self-assembled networks. Basic phenomena and functions were realized in vascular models, including fluid shear stress, cell strain, interstitial flow, endothelial permeation, angiogenesis, and thrombosis. In some models, endothelial cells were co-cultured with smooth muscle cells, pericytes, and fibroblasts in an extracellular matrix. Examples of vascular models involving the brain, lung, liver, kidney, placenta, and cancer were also introduced.
Collapse
Affiliation(s)
- Kae Sato
- Department of Chemical and Biological Sciences, Faculty of Science, Japan Women's University
| | - Kiichi Sato
- Department of Chemistry and Chemical Biology, School of Science and Technology, Gunma University
| |
Collapse
|
32
|
Muns SJ, Hoy JM, Murray PJ. Microchips for macropods: First use of a microchip-automated door by a bridled nailtail wallaby (Onychogalea fraenata). Zoo Biol 2018; 37:274-278. [PMID: 29923213 DOI: 10.1002/zoo.21419] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Revised: 05/17/2018] [Accepted: 05/25/2018] [Indexed: 11/06/2022]
Abstract
Commercially available microchip-automated devices for companion animals also have potential application with captive wildlife. To explore this potential, a captive bridled nailtail wallaby was trained to use a SureFlap Microchip Pet Door. Throughout the 62 day study the wallaby's interactions with the door increased in frequency and intensity, culminating in the repeated use of the microchip-automated door. This was the first record of any captive macropod being trained to use a microchip-automated device and demonstrates proof-of-concept that captive macropods can successfully utilize commercially available microchip-automated devices. Further research is recommended to develop methodology and evaluation techniques for training captive macropods while also exploring intra- and inter-species variations in responses.
Collapse
Affiliation(s)
- Sabrina J Muns
- School of Agriculture and Food Sciences, The University of Queensland, Gatton, Queensland, Australia
| | - Julia M Hoy
- Hidden Vale Wildlife Centre, The University of Queensland, Grandchester, Queensland, Australia
| | - Peter J Murray
- School of Agriculture and Food Sciences, The University of Queensland, Gatton, Queensland, Australia
- Hidden Vale Wildlife Centre, The University of Queensland, Grandchester, Queensland, Australia
| |
Collapse
|
33
|
Yang M, Huang Z, You H. A plug-in electrophoresis microchip with PCB electrodes for contactless conductivity detection. R Soc Open Sci 2018; 5:171687. [PMID: 29892366 PMCID: PMC5990721 DOI: 10.1098/rsos.171687] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2017] [Accepted: 04/03/2018] [Indexed: 06/08/2023]
Abstract
A plug-in electrophoresis microchip for large-scale use aimed at improving maintainability with low fabrication and maintenance costs is proposed in this paper. The plug-in microchip improves the maintainability of a device because the damaged microchannel layer can be changed without needing to cut off the circuit wires in the detection component. Obviously, the plug-in structure reduces waste compared with earlier microchips; at present the whole microchip has to be discarded, including the electrode layer and the microchannel layer. The fabrication cost was reduced as far as possible by adopting a steel template and printed circuit board electrodes that avoided the complex photolithography, metal deposition and sputtering processes. The detection performance of our microchip was assessed by electrophoresis experiments. The results showed an acceptable gradient and stable detection performance. The effect of the installation shift between the microchannel layer and the electrode layer brought about by the plug-in structure was also evaluated. The results indicated that, as long as the shift was controlled within a reasonable scope, its effect on the detection performance was acceptable. The plug-in microchip described in this paper represents a new train of thought for the large-scale use and design of portable instruments with electrophoresis microchips in the future.
Collapse
Affiliation(s)
- Mingpeng Yang
- Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031, Anhui, People's Republic of China
- University of Science and Technology of China, USTC, Hefei 230026, Anhui, People's Republic of China
| | - Zhe Huang
- Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031, Anhui, People's Republic of China
- University of Science and Technology of China, USTC, Hefei 230026, Anhui, People's Republic of China
| | - Hui You
- Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei 230031, Anhui, People's Republic of China
| |
Collapse
|
34
|
Goodwin K, Rand J, Morton J, Uthappa V, Walduck R. Email Reminders Increase the Frequency That Pet Owners Update Their Microchip Information. Animals (Basel) 2018; 8:E20. [PMID: 29385095 DOI: 10.3390/ani8020020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 01/25/2018] [Accepted: 01/25/2018] [Indexed: 11/29/2022] Open
Abstract
Simple Summary Many stray animals presented to shelters in several first world nations have incorrect contact details associated with their microchip and, consequently, cannot be reunited with their owners. This study investigated whether sending email reminders increased the frequency that pet owners updated their contact details on an Australian microchip database, and characterized the cat and dog population on this database. Email reminders were found to be effective at increasing the frequency that pet owners updated their contact details; frequency of updates also varied according to species, pet age, state or territory and socioeconomic differences. The information gained from this study can be used to increase owner compliance in keeping pet microchip contact details up to date, and therefore increase reclaim percentages of stray animals. Abstract Stray animals with incorrect microchip details are less likely to be reclaimed, and unclaimed strays are at increased risk of euthanasia. A retrospective cohort study was performed using 394,747 cats and 904,909 dogs registered with Australia’s largest microchip database to describe animal characteristics, determine whether annual email reminders increased the frequency that owners updated their information, and to compare frequencies of microchip information updates according to pet and owner characteristics. More than twice as many dogs (70%) than cats (30%) were registered on the database; the most numerous pure-breeds were Ragdoll cats and Staffordshire Bull Terrier dogs, and the number of registered animals per capita varied by Australian state or territory. Owners were more likely (p < 0.001) to update their details soon after they were sent a reminder email, compared to immediately before that email, and there were significant (p < 0.001) differences in the frequency of owner updates by state or territory of residence, animal species, animal age, and socioeconomic index of the owner’s postcode. This research demonstrates that email reminders increase the probability of owners updating their details on the microchip database, and this could reduce the percentages of stray animals that are unclaimed and subsequently euthanized.
Collapse
|
35
|
Yamamura S, Yamada E, Kimura F, Miyajima K, Shigeto H. Separation and Analysis of Adherent and Non-Adherent Cancer Cells Using a Single-Cell Microarray Chip. Sensors (Basel) 2017; 17:s17102410. [PMID: 29065470 PMCID: PMC5677269 DOI: 10.3390/s17102410] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Revised: 10/16/2017] [Accepted: 10/19/2017] [Indexed: 01/05/2023]
Abstract
A new single-cell microarray chip was designed and developed to separate and analyze single adherent and non-adherent cancer cells. The single-cell microarray chip is made of polystyrene with over 60,000 microchambers of 10 different size patterns (31–40 µm upper diameter, 11–20 µm lower diameter). A drop of suspension of adherent carcinoma (NCI-H1650) and non-adherent leukocyte (CCRF-CEM) cells was placed onto the chip, and single-cell occupancy of NCI-H1650 and CCRF-CEM was determined to be 79% and 84%, respectively. This was achieved by controlling the chip design and surface treatment. Analysis of protein expression in single NCI-H1650 and CCRF-CEM cells was performed on the single-cell microarray chip by multi-antibody staining. Additionally, with this system, we retrieved positive single cells from the microchambers by a micromanipulator. Thus, this system demonstrates the potential for easy and accurate separation and analysis of various types of single cells.
Collapse
Affiliation(s)
- Shohei Yamamura
- Health Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 2217-14 Hayashi-cho, Takamatsu, Kagawa 761-0395, Japan.
| | - Eriko Yamada
- Health Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 2217-14 Hayashi-cho, Takamatsu, Kagawa 761-0395, Japan.
| | - Fukiko Kimura
- Health Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 2217-14 Hayashi-cho, Takamatsu, Kagawa 761-0395, Japan.
| | - Kumiko Miyajima
- Health Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 2217-14 Hayashi-cho, Takamatsu, Kagawa 761-0395, Japan.
| | - Hajime Shigeto
- Health Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 2217-14 Hayashi-cho, Takamatsu, Kagawa 761-0395, Japan.
| |
Collapse
|
36
|
Man Y, Liang G, Li A, Pan L. Recent Advances in Mycotoxin Determination for Food Monitoring via Microchip. Toxins (Basel) 2017; 9:E324. [PMID: 29036884 PMCID: PMC5666371 DOI: 10.3390/toxins9100324] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 09/30/2017] [Accepted: 10/09/2017] [Indexed: 11/28/2022] Open
Abstract
Mycotoxins are one of the main factors impacting food safety. Mycotoxin contamination has threatened the health of humans and animals. Conventional methods for the detection of mycotoxins are gas chromatography (GC) or liquid chromatography (LC) coupled with mass spectrometry (MS), or enzyme-linked immunosorbent assay (ELISA). However, all these methods are time-consuming, require large-scale instruments and skilled technicians, and consume large amounts of hazardous regents and solvents. Interestingly, a microchip requires less sample consumption and short analysis time, and can realize the integration, miniaturization, and high-throughput detection of the samples. Hence, the application of a microchip for the detection of mycotoxins can make up for the deficiency of the conventional detection methods. This review focuses on the application of a microchip to detect mycotoxins in foods. The toxicities of mycotoxins and the materials of the microchip are firstly summarized in turn. Then the application of a microchip that integrates various kinds of detection methods (optical, electrochemical, photo-electrochemical, and label-free detection) to detect mycotoxins is reviewed in detail. Finally, challenges and future research directions in the development of a microchip to detect mycotoxins are previewed.
Collapse
Affiliation(s)
- Yan Man
- Beijing Research Center for Agricultural Standards and Testing, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Risk Assessment Lab for Agro-products, Ministry of Agriculture of the People's Republic of China, Beijing 100125, China.
- Beijing Municipal Key Laboratory of Agriculture Environment Monitoring, Beijing 100097, China.
| | - Gang Liang
- Beijing Research Center for Agricultural Standards and Testing, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Risk Assessment Lab for Agro-products, Ministry of Agriculture of the People's Republic of China, Beijing 100125, China.
- Beijing Municipal Key Laboratory of Agriculture Environment Monitoring, Beijing 100097, China.
| | - An Li
- Beijing Research Center for Agricultural Standards and Testing, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Risk Assessment Lab for Agro-products, Ministry of Agriculture of the People's Republic of China, Beijing 100125, China.
- Beijing Municipal Key Laboratory of Agriculture Environment Monitoring, Beijing 100097, China.
| | - Ligang Pan
- Beijing Research Center for Agricultural Standards and Testing, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Risk Assessment Lab for Agro-products, Ministry of Agriculture of the People's Republic of China, Beijing 100125, China.
- Beijing Municipal Key Laboratory of Agriculture Environment Monitoring, Beijing 100097, China.
| |
Collapse
|
37
|
Schulze F, Gao X, Virzonis D, Damiati S, Schneider MR, Kodzius R. Air Quality Effects on Human Health and Approaches for Its Assessment through Microfluidic Chips. Genes (Basel) 2017; 8:E244. [PMID: 28953246 PMCID: PMC5664094 DOI: 10.3390/genes8100244] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 09/11/2017] [Accepted: 09/20/2017] [Indexed: 01/16/2023] Open
Abstract
Air quality depends on the various gases and particles present in it. Both natural phenomena and human activities affect the cleanliness of air. In the last decade, many countries experienced an unprecedented industrial growth, resulting in changing air quality values, and correspondingly, affecting our life quality. Air quality can be accessed by employing microchips that qualitatively and quantitatively determine the present gases and dust particles. The so-called particular matter 2.5 (PM2.5) values are of high importance, as such small particles can penetrate the human lung barrier and enter the blood system. There are cancer cases related to many air pollutants, and especially to PM2.5, contributing to exploding costs within the healthcare system. We focus on various current and potential future air pollutants, and propose solutions on how to protect our health against such dangerous substances. Recent developments in the Organ-on-Chip (OoC) technology can be used to study air pollution as well. OoC allows determination of pollutant toxicity and speeds up the development of novel pharmaceutical drugs.
Collapse
Affiliation(s)
- Frank Schulze
- German Federal Institute for Risk Assessment (BfR), German Centre for the Protection of Laboratory Animals (Bf3R), 10589 Berlin, Germany.
| | - Xinghua Gao
- iSmart, Materials Genome Institute, Shanghai University (SHU), Shanghai 201800, China.
| | - Darius Virzonis
- Department of Electrical Engineering, Kaunas University of Technology, 35212 Panevezys, Lithuania.
| | - Samar Damiati
- Department of Biochemistry, King Abdulaziz University, Jeddah 80203, Saudi Arabia.
- Institute for Synthetic Bioarchitecture, Department of Nanobiotechnology, University of Natural Resources and Life Sciences, 1190 Vienna, Austria.
| | - Marlon R Schneider
- German Federal Institute for Risk Assessment (BfR), German Centre for the Protection of Laboratory Animals (Bf3R), 10589 Berlin, Germany.
| | - Rimantas Kodzius
- German Federal Institute for Risk Assessment (BfR), German Centre for the Protection of Laboratory Animals (Bf3R), 10589 Berlin, Germany.
- iSmart, Materials Genome Institute, Shanghai University (SHU), Shanghai 201800, China.
- Mathematics and Natural Sciences Department, The American University of Iraq, Sulaimani, Sulaymaniyah 46001, Iraq.
| |
Collapse
|
38
|
Hemy M, Rand J, Morton J, Paterson M. Characteristics and Outcomes of Dogs Admitted into Queensland RSPCA Shelters. Animals (Basel) 2017; 7:ani7090067. [PMID: 28862692 PMCID: PMC5615298 DOI: 10.3390/ani7090067] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Revised: 08/11/2017] [Accepted: 08/25/2017] [Indexed: 11/16/2022] Open
Abstract
Simple Summary An up-to-date and comprehensive understanding of the characteristics and outcomes of dogs entering shelters is required for implementing targeted strategies to reduce euthanasia of healthy and treatable dogs in Australia. Currently, there are few up-to-date Australian data published on dogs entering shelters, and their outcomes. Of dogs entering the Royal Society for Prevention of Cruelty to Animals, Queensland shelters in 2014, the majority (58%) were strays and 26% were puppies. Only 18% of dogs >6 months were desexed. Most dogs were reclaimed (32%) or adopted (43%). Strategies targeted to locations and breeds overrepresented by admissions are required to reduce shelter admissions, particularly of strays and unwanted litters. Abstract Over 200,000 stray and surrendered dogs are admitted to shelters and municipal facilities in Australia each year, and approximately 20% are euthanized. Contemporary, comprehensive data on the characteristics and outcomes of dogs entering shelters are required to reduce shelter admissions and euthanasia. However, there are currently limited up-to-date data published on dog admission into shelters. A retrospective single cohort study was conducted to describe the characteristics and outcomes of the dog population entering Royal Society for Prevention of Cruelty to Animals, Queensland (RSPCA-QLD) shelters in 2014 (n = 11,967). The majority of dog admissions were strays from the public (24%) or from municipal councils (34%). Just over a quarter of admissions were puppies, 18% of adults (>6 months) were desexed, and the majority of admissions were crossbred dogs (92%). The majority of owner surrenders (86%) were due to human-related reasons. Most dogs were reclaimed (32%) or adopted (43%) and aggression was the most common reason for euthanasia of adult dogs (45%). Low-cost or free desexing and identification programs targeted to areas and breeds contributing to high intake, and increased support services for owners at risk of surrendering their dog, should be trialed to determine their cost effectiveness in reducing shelter admissions and euthanasia.
Collapse
Affiliation(s)
- Megan Hemy
- School of Veterinary Science, The University of Queensland, Gatton, QLD 4343, Australia.
| | - Jacquie Rand
- School of Veterinary Science, The University of Queensland, Gatton, QLD 4343, Australia.
- Australian Pet Welfare Foundation, Kenmore, QLD 4069, Australia.
| | - John Morton
- School of Veterinary Science, The University of Queensland, Gatton, QLD 4343, Australia.
- Jemora Pty Ltd, Geelong, VIC 3220, Australia.
| | - Mandy Paterson
- School of Veterinary Science, The University of Queensland, Gatton, QLD 4343, Australia.
- RSPCA, Wacol, QLD 4076, Australia.
| |
Collapse
|
39
|
Yang X, Xu X, Zhang Y, Wen W, Gao X. 3D Microstructure Inhibits Mesenchymal Stem Cells Homing to the Site of Liver Cancer Cells on a Microchip. Genes (Basel) 2017; 8:E218. [PMID: 28862651 DOI: 10.3390/genes8090218] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 08/28/2017] [Accepted: 08/29/2017] [Indexed: 12/13/2022] Open
Abstract
The cell microenvironment consists of multiple types of biophysical and biochemical factors, and represents a complex integrated system that is variable in both time and space. Studies show that changes in biochemical and biophysical factors in cell microenvironments result in significant changes in cellular forms and functions, especially for stem cells. Mesenchymal stem cells (MSCs) are derived from adult stem cells of the mesoderm and play an important role in tissue engineering, regenerative medicine and even cancer therapy. Furthermore, it is found that MSCs can interact with multiple types of tumor cells. The interaction is reflected as two totally different aspects. The negative aspect is that MSCs manifest as tumor-associated fibroblasts and could induce migration of cancer cells and promote tumor formation. On the other hand, MSCs can home to sites of the tumor microenvironment, directionally migrate toward tumor cells and cause tumor cell apoptosis. In this study, we designed and made a simple microfluidic chip for cell co-culture, and studied stem cell homing behavior in the interaction between MSCs and liver cancer cells. Moreover, by etching a three-dimensional microstructure on the base and adding transforming growth factor-β (TGF-β) in the co-culture environment, we studied the impact of biophysical and biochemical factors on stem cell homing behavior, and the causes of such impact.
Collapse
|
40
|
González-Ramos MS, Santos-Moreno A, Rosas-Alquicira EF, Fuentes-Mascorro G. Validation of photo-identification as a mark-recapture method in the spotted eagle ray Aetobatus narinari. J Fish Biol 2017; 90:1021-1030. [PMID: 27885667 DOI: 10.1111/jfb.13215] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2016] [Accepted: 10/17/2016] [Indexed: 06/06/2023]
Abstract
The spotted eagle ray Aetobatus narinari is characterized by pigmentation patterns that are retained for up to 3·5 years. These pigmentations can be used to identify individuals through photo-identification. Only one study has validated this technique, but no study has estimated the percentage of correct identification of the rays using this technique. In order to carry out demographic research, a reliable photographic identification technique is needed. To achieve this validation for A. narinari, a double-mark system was established over 11 months and photographs of the dorsal surface of 191 rays were taken. Three body parts with distinctive natural patterns were analysed (dorsal surface of the cephalic region, dorsal surface of the pectoral fins and dorsal surface of the pelvic fins) in order to determine the body part that could be used to give the highest percentage of correct identification. The dorsal surface of the pectoral fins of A. narinari provides the most accurate photo-identification to distinguish individuals (88·2%).
Collapse
Affiliation(s)
- M S González-Ramos
- Laboratorio de Ecología Animal. Centro Interdisciplinario de Investigación para el Desarrollo Integral Regional, Unidad Oaxaca, Instituto Politécnico Nacional, Hornos 1003, Colonia La Noche Buena, Santa Cruz Xoxocotlán, Oaxaca, Código Postal 71230, México
| | - A Santos-Moreno
- Laboratorio de Ecología Animal. Centro Interdisciplinario de Investigación para el Desarrollo Integral Regional, Unidad Oaxaca, Instituto Politécnico Nacional, Hornos 1003, Colonia La Noche Buena, Santa Cruz Xoxocotlán, Oaxaca, Código Postal 71230, México
| | - E F Rosas-Alquicira
- Universidad del Mar, Campus Puerto Ángel, Instituto de Recursos, Ciudad Universitaria sin Número, San Pedro Pochutla, Oaxaca, Código Postal 70902, México
| | - G Fuentes-Mascorro
- Universidad Autónoma Benito Juárez de Oaxaca, Laboratorio de Investigación en Reproducción Animal, Avenida Universidad sin Número Colonia 5 Señores, Oaxaca de Juárez, Oaxaca, Código Postal 68120, México
| |
Collapse
|
41
|
Yao C, Song H, Wan Y, Ma K, Zheng C, Cui H, Xin P, Ji X, Deng S. Electro-Photodynamic Visualization of Singlet Oxygen Induced by Zinc Porphyrin Modified Microchip in Aqueous Media. ACS Appl Mater Interfaces 2016; 8:34833-34843. [PMID: 27762540 DOI: 10.1021/acsami.6b10213] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A porphyrin-based electro-photodynamic imaging system was fabricated for monitoring the concentration of oxygen. Distinct from the electrochemiluminescent (ECL) inability of numerous organic species in aqueous solutions, a strong and stable red irradiation at 634 nm could be stimulated electrochemically on zinc(II) meso-tetra(4-carboxyphenyl) porphine (ZnTCPP)/tetraoctylammonium bromide (TOAB) in the physiological condition. In terms of in situ electron paramagnetic resonance and ECL spectroscopies, the nature of ECL was thoroughly investigated, being exactly the chemiluminescence from singlet oxygen (1O2) produced during the successive electro-reduction of ZnTCPP. Meanwhile, the excellent film-making capacity of amphiphilic TOAB as a potent ion barrier granted the luminophores a micro-order and patternable electrode modification. Such platform was exceptionally tolerant of pH variation, facilitating a durable solid-state ECL visualization under potentiostatic electrolysis and time exposure in the charge-coupled device (CCD) camera. For flow-injection and real-time detection, a chip-mounted microfluidic cell was customized and manufactured. A sensitive and simple vision-sensing of O2 was further achieved with a real determination limit as low as a few micromolar level. The developed ECL imaging system is a good prototype and an eco-friendly technique in the cathodic range, and thus, it would supplement the primary anodic imaging library, showing great promise for multiplexed and colorimetric assays as well as oxygen-involved activity studies in the future.
Collapse
Affiliation(s)
- Chuanguang Yao
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Hongxin Song
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Ying Wan
- Intelligent Microsystem Technology and Engineering Center, School of Mechanical Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Kefeng Ma
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Chenyu Zheng
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Hongda Cui
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Peng Xin
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Xubo Ji
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Shengyuan Deng
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
- Materials Research Science and Engineering Centers (MRSEC), Department of Chemistry, Penn State University , University Park, Pennsylvania 16801, United States
| |
Collapse
|
42
|
Olds JE, Ewing J, Arruda P, Kuyper J, Riedesel E, Miles KM. IATROGENIC MICROCHIP ARTERIAL EMBOLISM IN A CHILEAN FLAMINGO (PHOENICOPTERUS CHILENSIS). J Zoo Wildl Med 2016; 47:686-90. [PMID: 27468052 DOI: 10.1638/2015-0168.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Aberrant microchip migration has been reported in domestic animal species, but in most cases, this migration is atraumatic to the patient. Reports of microchip-associated trauma and sarcoma development also have been reported in a variety of mammal species. This report describes accidental arterial microchip insertion causing obstruction of the iliac artery in a Chilean flamingo (Phoenicopterus chilensis). Diagnostic imaging included digital radiography and pre- and post-contrast computed tomography to determine the location of the microchip. Surgical removal of the microchip was attempted; however, the flamingo died intraoperatively. Postmortem evaluation found trauma to the epicardium, without penetration of the ventricle. The descending aorta was found traumatized and identified as the most likely insertion point leading to the embolism.
Collapse
|
43
|
Guldevall K, Brandt L, Forslund E, Olofsson K, Frisk TW, Olofsson PE, Gustafsson K, Manneberg O, Vanherberghen B, Brismar H, Kärre K, Uhlin M, Önfelt B. Microchip Screening Platform for Single Cell Assessment of NK Cell Cytotoxicity. Front Immunol 2016; 7:119. [PMID: 27092139 PMCID: PMC4820656 DOI: 10.3389/fimmu.2016.00119] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2015] [Accepted: 03/17/2016] [Indexed: 12/31/2022] Open
Abstract
Here, we report a screening platform for assessment of the cytotoxic potential of individual natural killer (NK) cells within larger populations. Human primary NK cells were distributed across a silicon-glass microchip containing 32,400 individual microwells loaded with target cells. Through fluorescence screening and automated image analysis, the numbers of NK and live or dead target cells in each well could be assessed at different time points after initial mixing. Cytotoxicity was also studied by time-lapse live-cell imaging in microwells quantifying the killing potential of individual NK cells. Although most resting NK cells (≈75%) were non-cytotoxic against the leukemia cell line K562, some NK cells were able to kill several (≥3) target cells within the 12-h long experiment. In addition, the screening approach was adapted to increase the chance to find and evaluate serial killing NK cells. Even if the cytotoxic potential varied between donors, it was evident that a small fraction of highly cytotoxic NK cells were responsible for a substantial portion of the killing. We demonstrate multiple assays where our platform can be used to enumerate and characterize cytotoxic cells, such as NK or T cells. This approach could find use in clinical applications, e.g., in the selection of donors for stem cell transplantation or generation of highly specific and cytotoxic cells for adoptive immunotherapy.
Collapse
Affiliation(s)
- Karolin Guldevall
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Ludwig Brandt
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Elin Forslund
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology, Solna, Sweden; Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet, Stockholm, Sweden
| | - Karl Olofsson
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Thomas W Frisk
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Per E Olofsson
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Karin Gustafsson
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Otto Manneberg
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Bruno Vanherberghen
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Hjalmar Brismar
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology , Solna , Sweden
| | - Klas Kärre
- Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet , Stockholm , Sweden
| | - Michael Uhlin
- Center for Allogeneic Stem Cell Transplantation, Huddinge University Hospital, Karolinska Institute, Stockholm, Sweden; Department of Oncology and Pathology, Karolinska Institutet, Stockholm, Sweden
| | - Björn Önfelt
- Science for Life Laboratory, Department of Applied Physics, KTH - Royal Institute of Technology, Solna, Sweden; Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
44
|
Lin S, Wang W, Ju XJ, Xie R, Liu Z, Yu HR, Zhang C, Chu LY. Ultrasensitive microchip based on smart microgel for real-time online detection of trace threat analytes. Proc Natl Acad Sci U S A 2016; 113:2023-8. [PMID: 26858435 DOI: 10.1073/pnas.1518442113] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Real-time online detection of trace threat analytes is critical for global sustainability, whereas the key challenge is how to efficiently convert and amplify analyte signals into simple readouts. Here we report an ultrasensitive microfluidic platform incorporated with smart microgel for real-time online detection of trace threat analytes. The microgel can swell responding to specific stimulus in flowing solution, resulting in efficient conversion of the stimulus signal into significantly amplified signal of flow-rate change; thus highly sensitive, fast, and selective detection can be achieved. We demonstrate this by incorporating ion-recognizable microgel for detecting trace Pb(2+), and connecting our platform with pipelines of tap water and wastewater for real-time online Pb(2+) detection to achieve timely pollution warning and terminating. This work provides a generalizable platform for incorporating myriad stimuli-responsive microgels to achieve ever-better performance for real-time online detection of various trace threat molecules, and may expand the scope of applications of detection techniques.
Collapse
|
45
|
Küchler A, Bleich JN, Sebastian B, Dittrich PS, Walde P. Stable and Simple Immobilization of Proteinase K Inside Glass Tubes and Microfluidic Channels. ACS Appl Mater Interfaces 2015; 7:25970-80. [PMID: 26536248 DOI: 10.1021/acsami.5b09301] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Engyodontium album proteinase K (proK) is widely used for degrading proteinaceous impurities during the isolation of nucleic acids from biological samples, or in proteomics and prion research. Toward applications of proK in flow reactors, a simple method for the stable immobilization of proK inside glass micropipette tubes was developed. The immobilization of the enzyme was achieved by adsorption of a dendronized polymer-enzyme conjugate from aqueous solution. This conjugate was first synthesized from a polycationic dendronized polymer (denpol) and proK and consisted, on average, of 2000 denpol repeating units and 140 proK molecules, which were attached along the denpol chain via stable bis-aryl hydrazone bonds. Although the immobilization of proK inside the tube was based on nonspecific, noncovalent interactions only, the immobilized proK did not leak from the tube and remained active during prolonged storage at 4 °C and during continuous operation at 25 °C and pH = 7.0. The procedure developed was successfully applied for the immobilization of proK on a glass/PDMS (polydimethylsiloxane) microchip, which is a requirement for applications in the field of proK-based protein analysis with such type of microfluidic devices.
Collapse
Affiliation(s)
- Andreas Küchler
- Polymer Chemistry Group, Department of Materials (D-MATL), ETH Zürich , Vladimir-Prelog-Weg 5, 8093 Zürich, Switzerland
| | - Julian N Bleich
- Polymer Chemistry Group, Department of Materials (D-MATL), ETH Zürich , Vladimir-Prelog-Weg 5, 8093 Zürich, Switzerland
| | - Bernhard Sebastian
- Bioanalytics Group, Department of Biosystems Science and Engineering (D-BSSE), ETH Zürich , Vladimir-Prelog-Weg 3, 8093 Zürich, Switzerland
| | - Petra S Dittrich
- Bioanalytics Group, Department of Biosystems Science and Engineering (D-BSSE), ETH Zürich , Vladimir-Prelog-Weg 3, 8093 Zürich, Switzerland
| | - Peter Walde
- Polymer Chemistry Group, Department of Materials (D-MATL), ETH Zürich , Vladimir-Prelog-Weg 5, 8093 Zürich, Switzerland
| |
Collapse
|
46
|
Xu Y, Mawatari K, Konno T, Kitamori T, Ishihara K. Spontaneous Packaging and Hypothermic Storage of Mammalian Cells with a Cell-Membrane-Mimetic Polymer Hydrogel in a Microchip. ACS Appl Mater Interfaces 2015; 7:23089-23097. [PMID: 26436637 DOI: 10.1021/acsami.5b06796] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Currently, continuous culture/passage and cryopreservation are two major, well-established methods to provide cultivated mammalian cells for experiments in laboratories. Due to the lack of flexibility, however, both laboratory-oriented methods are unable to meet the need for rapidly growing cell-based applications, which require cell supply in a variety of occasions outside of laboratories. Herein, we report spontaneous packaging and hypothermic storage of mammalian cells under refrigerated (4 °C) and ambient conditions (25 °C) using a cell-membrane-mimetic methacryloyloxyethyl phosphorylcholine (MPC) polymer hydrogel incorporated within a glass microchip. Its capability for hypothermic storage of cells was comparatively evaluated over 16 days. The results reveal that the cytocompatible MPC polymer hydrogel, in combination with the microchip structure, enabled hypothermic storage of cells with quite high viability, high intracellular esterase activity, maintained cell membrane integrity, and small morphological change for more than 1 week at 4 °C and at least 4 days at 25 °C. Furthermore, the stored cells could be released from the hydrogel and exhibited the ability to adhere to a surface and achieve confluence under standard cell culture conditions. Both hypothermic storage conditions are ordinary flexible conditions which can be easily established in places outside of laboratories. Therefore, cell packaging and storage using the hydrogel incorporated within the microchip would be a promising miniature and portable solution for flexible supply and delivery of small amounts of cells from bench to bedside.
Collapse
Affiliation(s)
- Yan Xu
- Nanoscience and Nanotechnology Research Center, Research Organization for the 21st Century, Osaka Prefecture University , 1-2, Gakuen-cho, Naka-ku, Sakai, Osaka 599-8570, Japan
| | - Kazuma Mawatari
- Department of Applied Chemistry, School of Engineering, The University of Tokyo , 7-3-1, Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Tomohiro Konno
- Department of Materials Engineering, School of Engineering, The University of Tokyo , 7-3-1, Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Takehiko Kitamori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo , 7-3-1, Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Kazuhiko Ishihara
- Department of Materials Engineering, School of Engineering, The University of Tokyo , 7-3-1, Hongo, Bunkyo, Tokyo, 113-8656, Japan
| |
Collapse
|
47
|
Li L, Wang Y, Chen C, Wang X, Luo J. Comprehensive theoretical analysis and experimental exploration of ultrafast microchip-based high-field asymmetric ion mobility spectrometry (FAIMS) technique. J Mass Spectrom 2015; 50:792-801. [PMID: 26169133 DOI: 10.1002/jms.3580] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2014] [Revised: 02/12/2015] [Accepted: 02/12/2015] [Indexed: 06/04/2023]
Abstract
High-field asymmetric ion mobility spectrometry (FAIMS) has become an efficient technique for separation and characterization of gas-phase ions at ambient pressure, which utilizes the mobility differences of ions at high and low fields. Micro FAIMS devices made by micro-electromechanical system technology have small gaps of the channels, high electric field and good installation precision, as thus they have received great attentions. However, the disadvantage of relatively low resolution limits their applications in some areas. In this study, theoretical analysis and experimental exploration were carried out to overcome the disadvantage. Multiple scans, characteristic decline curves of ion transmission and pattern recognitions were proposed to improve the performance of the microchip-based FAIMS. The results showed that although micro FAIMS instruments as a standalone chemical analyzer suffer from low resolution, by using one or more of the methods proposed, they can identify chemicals precisely and provide quantitative analysis with low detection limit in some applications. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Lingfeng Li
- Department of Information Science & Electronic Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yonghuan Wang
- Department of Information Science & Electronic Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Chilai Chen
- State Key Laboratory of Transducer Technology, Hefei Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, China
| | - Xiaozhi Wang
- Department of Information Science & Electronic Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Jikui Luo
- Department of Information Science & Electronic Engineering, Zhejiang University, Hangzhou, 310027, China
| |
Collapse
|
48
|
Lancaster E, Rand J, Collecott S, Paterson M. Problems Associated with the Microchip Data of Stray Dogs and Cats Entering RSPCA Queensland Shelters. Animals (Basel) 2015; 5:332-48. [PMID: 26479238 DOI: 10.3390/ani5020332] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Revised: 04/01/2015] [Accepted: 04/20/2015] [Indexed: 11/17/2022] Open
Abstract
A lack of published information documenting problems with the microchip data for the reclaiming of stray animals entering Australian shelters limits improvement of the current microchipping system. A retrospective study analysing admission data for stray, adult dogs (n = 7258) and cats (n = 6950) entering the Royal Society for the Prevention of Cruelty to Animals (RSPCA) Queensland between January 2012 and December 2013 was undertaken to determine the character and frequency of microchip data problems and their impact on outcome for the animal. Only 28% of dogs and 9% of cats were microchipped, and a substantial proportion (37%) had problems with their data, including being registered to a previous owner or organisation (47%), all phone numbers incorrect/disconnected (29%), and the microchip not registered (14%). A higher proportion of owners could be contacted when the microchip had no problems, compared to those with problems (dogs, 93% vs. 70%; cats, 75% vs. 41%). The proportion of animals reclaimed declined significantly between microchipped animals with no data problems, microchipped animals with data problems and non-microchipped animals-87%, 69%, and 37%, respectively, for dogs and 61%, 33%, and 5%, respectively, for cats. Strategies are needed to increase the accuracy of microchip data to facilitate the reclaiming of stray dogs and cats.
Collapse
|
49
|
Tauriainen J, Gustafsson K, Göthlin M, Gertow J, Buggert M, Frisk TW, Karlsson AC, Uhlin M, Önfelt B. Single-Cell Characterization of in vitro Migration and Interaction Dynamics of T Cells Expanded with IL-2 and IL-7. Front Immunol 2015; 6:196. [PMID: 25972868 PMCID: PMC4412128 DOI: 10.3389/fimmu.2015.00196] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2014] [Accepted: 04/09/2015] [Indexed: 12/27/2022] Open
Abstract
T cells are pivotal in the immune defense against cancers and infectious agents. To mount an effector response against cancer cells, T cells need to migrate to the cancer-site, engage in contacts with cancer cells, and perform their effector functions. Adoptive T cell therapy is an effective strategy as treatment of complications such as relapse or opportunistic infections after hematopoietic stem cell transplantations. This requires a sufficient amount of cells that are able to expand and respond to tumor or viral antigens. The cytokines interleukin (IL)-2 and IL-7 drive T cell differentiation, proliferation, and survival and are commonly used to expand T cells ex vivo. Here, we have used microchip-based live-cell imaging to follow the migration of individual T cells, their interactions with allogeneic monocytes, cell division, and apoptosis for extended periods of time; something that cannot be achieved by commonly used methods. Our data indicate that cells grown in IL-7 + IL-2 had similar migration and contact dynamics as cells grown in IL-2 alone. However, the addition of IL-7 decreased cell death creating a more viable cell population, which should be beneficial when preparing cells for immunotherapy.
Collapse
Affiliation(s)
- Johanna Tauriainen
- Department of Laboratory Medicine, Division of Clinical Microbiology, Karolinska Institutet , Stockholm , Sweden
| | - Karin Gustafsson
- Science for Life Laboratory, Department of Applied Physics, KTH Royal Institute of Technology , Stockholm , Sweden
| | - Mårten Göthlin
- Science for Life Laboratory, Department of Applied Physics, KTH Royal Institute of Technology , Stockholm , Sweden
| | - Jens Gertow
- Center for Allogeneic Stem Cell Transplantation, Karolinska University Hospital Huddinge , Stockholm , Sweden ; Department of Oncology and Pathology, Karolinska Institutet , Stockholm , Sweden
| | - Marcus Buggert
- Department of Laboratory Medicine, Division of Clinical Microbiology, Karolinska Institutet , Stockholm , Sweden
| | - Thomas W Frisk
- Science for Life Laboratory, Department of Applied Physics, KTH Royal Institute of Technology , Stockholm , Sweden
| | - Annika C Karlsson
- Department of Laboratory Medicine, Division of Clinical Microbiology, Karolinska Institutet , Stockholm , Sweden
| | - Michael Uhlin
- Center for Allogeneic Stem Cell Transplantation, Karolinska University Hospital Huddinge , Stockholm , Sweden ; Department of Oncology and Pathology, Karolinska Institutet , Stockholm , Sweden
| | - Björn Önfelt
- Science for Life Laboratory, Department of Applied Physics, KTH Royal Institute of Technology , Stockholm , Sweden ; Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet , Stockholm , Sweden
| |
Collapse
|
50
|
Hoskinson C, McCain S, Allender MC. Comparison of body temperature readings between an implantable microchip and a cloacal probe in lorikeets (Trichoglossus haematodus sp.). Zoo Biol 2014; 33:452-4. [PMID: 25270528 DOI: 10.1002/zoo.21174] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 06/10/2014] [Accepted: 08/13/2014] [Indexed: 11/08/2022]
Abstract
Body temperature readings can be a useful diagnostic tool for identifying the presence of subclinical disease. Traditionally, rectal or cloacal thermometry has been used to obtain body temperatures. The use of implantable microchips to obtain these temperatures has been studied in a variety of animals, but not yet in avian species. Initially, timepoint one (T₁), nine lorikeets were anesthetized via facemask induction with 5% isoflurane and maintained at 2-3% for microchip placement and body temperature data collection. Body temperature was measured at 0 and 2 min post-anesthetic induction both cloacally, using a Cardell veterinary monitor and also via implantable microchip, utilizing a universal scanner. On two more occasions, timepoints two and three (T₂, T₃), the same nine lorikeets were manually restrained to obtain body temperature readings both cloacally and via microchip, again at minutes 0 and 2. There was no statistical difference between body temperatures, for both methods, at T₁. Microchip temperatures were statistically different than cloacal temperatures at T₂ and T₃. Body temperatures at T₁, were statistically different from those obtained at T₂ and T₃ for both methods. Additional studies are warranted to verify the accuracy of microchip core body temperature readings in avian species.
Collapse
|