1
|
Mahmud S, Ramproshad S, Deb R, Dutta D. A review of the zone broadening contributions in free-flow electrophoresis. Electrophoresis 2023; 44:1519-1538. [PMID: 37548630 DOI: 10.1002/elps.202300062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/20/2023] [Accepted: 07/18/2023] [Indexed: 08/08/2023]
Abstract
The broadening of analyte streams, as they migrate through a free-flow electrophoresis (FFE) channel, often limits the resolving power of FFE separations. Under laminar flow conditions, such zonal spreading occurs due to analyte diffusion perpendicular to the direction of streamflow and variations in the lateral distance electrokinetically migrated by the analyte molecules. Although some of the factors that give rise to these contributions are inherent to the FFE method, others originate from non-idealities in the system, such as Joule heating, pressure-driven crossflows, and a difference between the electrical conductivities of the sample stream and background electrolyte. The injection process can further increase the stream width in FFE separations but normally influencing all analyte zones to an equal extent. Recently, several experimental and theoretical works have been reported that thoroughly investigate the various contributions to stream variance in an FFE device for better understanding, and potentially minimizing their magnitudes. In this review article, we carefully examine the findings from these studies and discuss areas in which more work is needed to advance our comprehension of the zone broadening contributions in FFE assays.
Collapse
Affiliation(s)
- Sakur Mahmud
- Department of Chemistry, University of Wyoming, Laramie, Wyoming, USA
| | - Sarker Ramproshad
- Department of Chemistry, University of Wyoming, Laramie, Wyoming, USA
| | - Rajesh Deb
- Department of Chemistry, University of Wyoming, Laramie, Wyoming, USA
| | - Debashis Dutta
- Department of Chemistry, University of Wyoming, Laramie, Wyoming, USA
| |
Collapse
|
2
|
Zhang A, Xu J, Li X, Lin Z, Song Y, Li X, Wang Z, Cheng Y. High-Throughput Continuous-Flow Separation in a Micro Free-Flow Electrophoresis Glass Chip Based on Laser Microfabrication. SENSORS (BASEL, SWITZERLAND) 2022; 22:1124. [PMID: 35161869 PMCID: PMC8838507 DOI: 10.3390/s22031124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 01/20/2022] [Accepted: 01/28/2022] [Indexed: 06/14/2023]
Abstract
Micro free-flow electrophoresis (μFFE) provides a rapid and straightforward route for the high-performance online separation and purification of targeted liquid samples in a mild manner. However, the facile fabrication of a μFFE device with high throughput and high stability remains a challenge due to the technical barriers of electrode integration and structural design for the removal of bubbles for conventional methods. To address this, the design and fabrication of a high-throughput μFFE chip are proposed using laser-assisted chemical etching of glass followed by electrode integration and subsequent low-temperature bonding. The careful design of the height ratio of the separation chamber and electrode channels combined with a high flow rate of buffer solution allows the efficient removal of electrolysis-generated bubbles along the deep electrode channels during continuous-flow separation. The introduction of microchannel arrays further enhances the stability of on-chip high-throughput separation. As a proof-of-concept, high-performance purification of fluorescein sodium solution with a separation purity of ~97.9% at a voltage of 250 V from the mixture sample solution of fluorescein sodium and rhodamine 6G solution is demonstrated.
Collapse
Affiliation(s)
- Aodong Zhang
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Jian Xu
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Xiaolong Li
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Zijie Lin
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Yunpeng Song
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Xin Li
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
| | - Zhenhua Wang
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Ya Cheng
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
- State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
| |
Collapse
|
3
|
Microfluidic free-flow electrophoresis: a promising tool for protein purification and analysis in proteomics. J IND ENG CHEM 2022. [DOI: 10.1016/j.jiec.2022.02.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
4
|
Park S, Hong S, Kim J, Son SY, Lee H, Kim SJ. Eco friendly nanofluidic platforms using biodegradable nanoporous materials. Sci Rep 2021; 11:3804. [PMID: 33589696 PMCID: PMC7884701 DOI: 10.1038/s41598-021-83306-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 02/02/2021] [Indexed: 11/09/2022] Open
Abstract
Splendid advancement of micro/nanofluidic researches in the field of bio- and chemical-analysis enables various ubiquitous applications such as bio-medical diagnostics and environmental monitoring, etc. In such devices, nanostructures are the essential elements so that the nanofabrication methods have been major issues since the last couple of decades. However, most of nanofabrication methods are sophisticated and expensive due to the requirement of high-class cleanroom facilities, while low-cost and biocompatible materials have been already introduced in the microfluidic platforms. Thus, an off-the-shelf and biodegradable material for those nanostructures can complete the concept of an eco-friendly micro/nanofluidic platform. In this work, biodegradable materials originated from well-known organisms such as human nail plate and denatured hen egg (albumen and yolk) were rigorously investigated as a perm-selective nanoporous membrane. A simple micro/nanofluidic device integrated with such materials was fabricated to demonstrate nanofluidic phenomena. These distinctive evidences (the visualization of ion concentration polarization phenomenon, ohmic/limiting/over-limiting current behavior and surface charge-governed conductance) can fulfill the requirements of functional nanostructures for the nanofluidic applications. Therefore, while these materials were less robust than nano-lithographically fabricated structures, bio-oriented perm-selective materials would be utilized as a one of key elements of the biodegradable and eco friendly micro/nanofluidic applications.
Collapse
Affiliation(s)
- Sungmin Park
- Department of Electrical and Computer Engineering, Seoul National University, Seoul, 08826, Republic of Korea
| | - Seongjun Hong
- Department of Electrical and Computer Engineering, Seoul National University, Seoul, 08826, Republic of Korea
| | - Junsuk Kim
- Department of Electrical and Computer Engineering, Seoul National University, Seoul, 08826, Republic of Korea
| | - Seok Young Son
- Department of Electrical and Computer Engineering, Seoul National University, Seoul, 08826, Republic of Korea
| | - Hyomin Lee
- Department of Chemical and Biological Engineering, Jeju National University, Jeju, 63243, Republic of Korea
| | - Sung Jae Kim
- Department of Electrical and Computer Engineering, Seoul National University, Seoul, 08826, Republic of Korea. .,Nano System Institute, Seoul National University, Seoul, 08826, Republic of Korea. .,Inter-University Semiconductor Research Center, Seoul National University, Seoul, 08826, Republic of Korea.
| |
Collapse
|
5
|
|
6
|
Kim W, Oh J, Kwon S, Kim K, Kim SJ. Quantifying the pH shift induced by selective anodic electrochemical reactions in the ion concentration polarization phenomenon. LAB ON A CHIP 2019; 19:1359-1369. [PMID: 30869092 DOI: 10.1039/c8lc01363b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Recently, the ion concentration polarization (ICP) phenomenon has been actively utilized for low abundance biomolecular preconcentration applications. Since ICP significantly rearranges the ion distribution near a permselective membrane, its detailed investigation should be conducted for developing efficient platforms. In particular, proton transport through the membrane critically affects the pH of sample solutions so that continuous monitoring or batch measurement of pH is the priority task to be carried out. Moreover, electrochemical reactions have been overlooked, even though an overpotential is applied to preconcentrate a sample under physiological conditions, and the electrodes are in direct contact with the sample biomolecules. In this work, we experimentally visualized and directly measured how the electrochemical reaction dominated the preconcentration efficiency using two types of electrode configurations; large exposed electrode area (LEEA) and small exposed electrode area (SEEA). Interestingly, significant pH variation was confirmed only in the case of SEEA. As a result, the BSA preconcentration was impeded within a short period in the case of SEEA, but loss-free preconcentration was achieved in the case of LEEA. Therefore, one should pay careful attention to the electrode design of electrokinetic operation, especially when pH-sensitive biomolecules are involved.
Collapse
Affiliation(s)
- Wonseok Kim
- Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Republic of Korea.
| | | | | | | | | |
Collapse
|
7
|
Abstract
Micro free-flow electrophoresis (μFFE) is a continuous separation technique in which analytes are streamed through a perpendicularly applied electric field in a planar separation channel. Analyte streams are deflected laterally based on their electrophoretic mobilities as they flow through the separation channel. A number of μFFE separation modes have been demonstrated, including free zone (FZ), micellar electrokinetic chromatography (MEKC), isoelectric focusing (IEF) and isotachophoresis (ITP). Approximately 60 articles have been published since the first μFFE device was fabricated in 1994. We anticipate that recent advances in device design, detection, and fabrication, will allow μFFE to be applied to a much wider range of applications. Applications particularly well suited for μFFE analysis include continuous, real time monitoring and microscale purifications.
Collapse
Affiliation(s)
- Alexander C Johnson
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, MN 55455, USA.
| | | |
Collapse
|
8
|
Novo P, Janasek D. Current advances and challenges in microfluidic free-flow electrophoresis-A critical review. Anal Chim Acta 2017; 991:9-29. [PMID: 29031303 DOI: 10.1016/j.aca.2017.08.017] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 08/10/2017] [Accepted: 08/11/2017] [Indexed: 12/30/2022]
Abstract
The research field on microfluidic free-flow electrophoresis has developed vast amounts of devices, methods, applications and raised new questions, often in analogy to conventional techniques from which it derives. Most efforts have been employed on device development and a myriad of architectures and fabrication techniques have been reported using simple proof-of-principle separations. As technological aspects reach a quite mature state, researchers' new challenges include the development of protocols for the separation of complex mixtures, as required in the fields of application. The success of this effort is extremely dependent on the capability to transfer the device's fabrication to an industrial setting as well as to ensure interfacing simplicity, namely at the solutions' supply and collection, and actuation such as electric potential application and temperature control. Other advanced applications such as direct interfacing to downstream systems such as mass spectrometry, integration of sensing and feedback controls will require further development in the laboratory. In this review we provide an overview on the field, from basic concepts, through advanced developments both in the theoretical and experimental arenas, and addressing the above details. A comprehensive survey of designs, materials and applications is presented with particular highlights to most recent developments, namely the integration of electrodes, flow control and hyphenation of microfluidic free-flow electrophoresis with other techniques.
Collapse
Affiliation(s)
- Pedro Novo
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., 44227, Otto-Hahn-Str. 6b, Dortmund, Germany
| | - Dirk Janasek
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., 44227, Otto-Hahn-Str. 6b, Dortmund, Germany.
| |
Collapse
|
9
|
Novo P, Dell'Aica M, Jender M, Höving S, Zahedi RP, Janasek D. Integration of polycarbonate membranes in microfluidic free-flow electrophoresis. Analyst 2017; 142:4228-4239. [DOI: 10.1039/c7an01514c] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
A general difficulty in the miniaturization of free-flow electrophoresis relates to the need to separate electrodes and separation bed compartments.
Collapse
Affiliation(s)
- Pedro Novo
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V
- 44227 Dortmund
- Germany
| | - Margherita Dell'Aica
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V
- 44227 Dortmund
- Germany
| | - Matthias Jender
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V
- 44227 Dortmund
- Germany
| | - Stefan Höving
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V
- 44227 Dortmund
- Germany
| | - René P. Zahedi
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V
- 44227 Dortmund
- Germany
| | - Dirk Janasek
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V
- 44227 Dortmund
- Germany
| |
Collapse
|
10
|
Fu X, Mavrogiannis N, Ibo M, Crivellari F, Gagnon ZR. Microfluidic free-flow zone electrophoresis and isotachophoresis using carbon black nano-composite PDMS sidewall membranes. Electrophoresis 2016; 38:327-334. [DOI: 10.1002/elps.201600104] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2016] [Revised: 05/12/2016] [Accepted: 05/13/2016] [Indexed: 11/11/2022]
Affiliation(s)
- Xiaotong Fu
- Department of Chemical and Biomolecular Engineering; Johns Hopkins University; Baltimore MD USA
| | - Nicholas Mavrogiannis
- Department of Chemical and Biomolecular Engineering; Johns Hopkins University; Baltimore MD USA
| | - Markela Ibo
- Department of Chemical and Biomolecular Engineering; Johns Hopkins University; Baltimore MD USA
| | - Francesca Crivellari
- Department of Chemical and Biomolecular Engineering; Johns Hopkins University; Baltimore MD USA
| | - Zachary R. Gagnon
- Department of Chemical and Biomolecular Engineering; Johns Hopkins University; Baltimore MD USA
| |
Collapse
|
11
|
Engineered nanofluidic preconcentration devices by ion concentration polarization. BIOCHIP JOURNAL 2016. [DOI: 10.1007/s13206-016-0401-7] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
Hong S, Kwak R, Kim W. Paper-Based Flow Fractionation System Applicable to Preconcentration and Field-Flow Separation. Anal Chem 2016; 88:1682-7. [DOI: 10.1021/acs.analchem.5b03682] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Seokbin Hong
- Department
of Mechanical Engineering, Sogang University, Seoul, 121-742, Republic of Korea
| | - Rhokyun Kwak
- Center
for BioMicrosystems, Korea Institute of Science and Technology, Seoul, 136-791, Republic of Korea
| | - Wonjung Kim
- Department
of Mechanical Engineering, Sogang University, Seoul, 121-742, Republic of Korea
| |
Collapse
|
13
|
Novel Electrokinetic Microfluidic Detector for Evaluating Effectiveness of Microalgae Disinfection in Ship Ballast Water. Int J Mol Sci 2015; 16:25560-75. [PMID: 26516836 PMCID: PMC4632816 DOI: 10.3390/ijms161025560] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Revised: 08/13/2015] [Accepted: 10/13/2015] [Indexed: 11/17/2022] Open
Abstract
Ship ballast water treatment methods face many technical challenges. The effectiveness of every treatment method usually is evaluated by using large scale equipment and a large volume of samples, which involves time-consuming, laborious, and complex operations. This paper reports the development of a novel, simple and fast platform of methodology in evaluating the efficiency and the best parameters for ballast water treatment systems, particularly in chemical disinfection. In this study, a microfluidic chip with six sample wells and a waste well was designed, where sample transportation was controlled by electrokinetic flow. The performance of this microfluidic platform was evaluated by detecting the disinfection of Dunaliella salina (D. salina) algae in ballast water treated by sodium hypochlorite (NaClO) solution. Light-induced chlorophyll fluorescence (LICF) intensity was used to determine the viability of microalgae cells in the system, which can be operated automatically with the dimension of the detector as small as 50 mm × 24 mm × 5 mm. The 40 µL volume of sample solution was used for each treatment condition test and the validity of detection can be accomplished within about five min. The results show that the viability of microalgae cells under different treatment conditions can be determined accurately and further optimal treatment conditions including concentrations of NaClO and treatment time can also be obtained. These results can provide accurate evaluation and optimal parameters for ballast water treatment methods.
Collapse
|
14
|
Present state of microchip electrophoresis: state of the art and routine applications. J Chromatogr A 2014; 1382:66-85. [PMID: 25529267 DOI: 10.1016/j.chroma.2014.11.034] [Citation(s) in RCA: 130] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 11/07/2014] [Accepted: 11/12/2014] [Indexed: 12/20/2022]
Abstract
Microchip electrophoresis (MCE) was one of the earliest applications of the micro-total analysis system (μ-TAS) concept, whose aim is to reduce analysis time and reagent and sample consumption while increasing throughput and portability by miniaturizing analytical laboratory procedures onto a microfluidic chip. More than two decades on, electrophoresis remains the most common separation technique used in microfluidic applications. MCE-based instruments have had some commercial success and have found application in many disciplines. This review will consider the present state of MCE including recent advances in technology and both novel and routine applications in the laboratory. We will also attempt to assess the impact of MCE in the scientific community and its prospects for the future.
Collapse
|