Woodward SE, Pieczonka SA, Hertzog J, Haydock R, Thomas MJ, Roullier-Gall C, O'Flynn C, Uhl J, Rychlik M, Schmitt-Kopplin P, Marshall JW. Continuum of non-targeted data for long term study of complex samples generated by direct infusion ultra-high resolution mass spectrometry. Talanta 2025; 286:127514. [PMID: 39793180 DOI: 10.1016/j.talanta.2024.127514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2024] [Revised: 12/20/2024] [Accepted: 12/31/2024] [Indexed: 01/13/2025]
Abstract
Non-targeted chemical analysis is a powerful tool for exploration of the unknown chemistry of complex matrices such as food, biological, geochemical, environmental and even extra-terrestrial samples. It allows researchers to ask open, unbiased questions about their system chemistry. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS) offers these options and has been widely used to study complex mixtures, with its unmatched mass resolution enabling direct infusion methods and eliminating the challenges of chromatographic alignment in large-scale longitudinal projects. In this article, we demonstrate the use of FT-ICR-MS for generating a dataset for hundreds of complex samples with diverse chemistries over a period of 6 years and 32 batches, allowing confident comparison of data between samples from different batches. The resulting chemical database will be continuously expanded in future and retrospectively interrogated to test new hypotheses utilizing data of past projects and new knowledge of coming projects. We discuss the experimental setup and how other researchers could apply the same approaches, which is relevant for wide ranging applications and research fields.
Collapse
Affiliation(s)
- Susanne E Woodward
- Waltham Petcare Science Institute, Mars Petcare, Freeby Lane, Waltham on the Wolds, Melton Mowbray, LE14 4RT, United Kingdom
| | - Stefan A Pieczonka
- Technical University of Munich, Analytical Food Chemistry, Maximus-von-Imhof Forum 2, 85453, Freising, Germany; Helmholtz Munich, Analytical BioGeoChemistry, Ingolstädter Landstr 1, 85764, Neuherberg, Germany
| | - Jasmine Hertzog
- Technical University of Munich, Analytical Food Chemistry, Maximus-von-Imhof Forum 2, 85453, Freising, Germany; Helmholtz Munich, Analytical BioGeoChemistry, Ingolstädter Landstr 1, 85764, Neuherberg, Germany
| | - Richard Haydock
- Waltham Petcare Science Institute, Mars Petcare, Freeby Lane, Waltham on the Wolds, Melton Mowbray, LE14 4RT, United Kingdom
| | - Mary J Thomas
- Waltham Petcare Science Institute, Mars Petcare, Freeby Lane, Waltham on the Wolds, Melton Mowbray, LE14 4RT, United Kingdom
| | - Chloé Roullier-Gall
- Technical University of Munich, Analytical Food Chemistry, Maximus-von-Imhof Forum 2, 85453, Freising, Germany; Helmholtz Munich, Analytical BioGeoChemistry, Ingolstädter Landstr 1, 85764, Neuherberg, Germany
| | - Ciaran O'Flynn
- Waltham Petcare Science Institute, Mars Petcare, Freeby Lane, Waltham on the Wolds, Melton Mowbray, LE14 4RT, United Kingdom
| | - Jenny Uhl
- Technical University of Munich, Analytical Food Chemistry, Maximus-von-Imhof Forum 2, 85453, Freising, Germany; Helmholtz Munich, Analytical BioGeoChemistry, Ingolstädter Landstr 1, 85764, Neuherberg, Germany
| | - Michael Rychlik
- Technical University of Munich, Analytical Food Chemistry, Maximus-von-Imhof Forum 2, 85453, Freising, Germany
| | - Philippe Schmitt-Kopplin
- Technical University of Munich, Analytical Food Chemistry, Maximus-von-Imhof Forum 2, 85453, Freising, Germany; Helmholtz Munich, Analytical BioGeoChemistry, Ingolstädter Landstr 1, 85764, Neuherberg, Germany
| | - James W Marshall
- Waltham Petcare Science Institute, Mars Petcare, Freeby Lane, Waltham on the Wolds, Melton Mowbray, LE14 4RT, United Kingdom.
| |
Collapse
|
2
|
Claesen J, Rockwood A, Gorshkov M, Valkenborg D. The isotope distribution: A rose with thorns. MASS SPECTROMETRY REVIEWS 2025; 44:22-42. [PMID: 36744702 PMCID: PMC11624904 DOI: 10.1002/mas.21820] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 10/03/2022] [Accepted: 10/21/2022] [Indexed: 06/18/2023]
Abstract
The isotope distribution, which reflects the number and probabilities of occurrence of different isotopologues of a molecule, can be theoretically calculated. With the current generation of (ultra)-high-resolution mass spectrometers, the isotope distribution of molecules can be measured with high sensitivity, resolution, and mass accuracy. However, the observed isotope distribution can differ substantially from the expected isotope distribution. Although differences between the observed and expected isotope distribution can complicate the analysis and interpretation of mass spectral data, they can be helpful in a number of specific applications. These applications include, yet are not limited to, the identification of peptides in proteomics, elucidation of the elemental composition of small organic molecules and metabolites, as well as wading through peaks in mass spectra of complex bioorganic mixtures such as petroleum and humus. In this review, we give a nonexhaustive overview of factors that have an impact on the observed isotope distribution, such as elemental isotope deviations, ion sampling, ion interactions, electronic noise and dephasing, centroiding, and apodization. These factors occur at different stages of obtaining the isotope distribution: during the collection of the sample, during the ionization and intake of a molecule in a mass spectrometer, during the mass separation and detection of ionized molecules, and during signal processing.
Collapse
Affiliation(s)
- Jürgen Claesen
- Department of Epidemiology and Data Science, Amsterdam UMC, Vrije Universiteit AmsterdamEpidemiology and Data ScienceAmsterdamThe Netherlands
- I‐Biostat, Data Science InstituteHasselt UniversityHasseltBelgium
| | - Alan Rockwood
- Department of PathologyUniversity of Utah School of MedicineSalt Lake CityUtahUSA
| | - Mikhail Gorshkov
- V.L. Talrose Institute for Energy Problems of Chemical Physics, N.N. Semenov Federal Research Center for Chemical PhysicsRussian Academy of SciencesMoscowRussia
| | - Dirk Valkenborg
- I‐Biostat, Data Science InstituteHasselt UniversityHasseltBelgium
| |
Collapse
|
3
|
Barskiy DA. Molecules, Up Your Spins! Molecules 2024; 29:1821. [PMID: 38675641 PMCID: PMC11052189 DOI: 10.3390/molecules29081821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Accepted: 04/08/2024] [Indexed: 04/28/2024] Open
Abstract
Nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) are indispensable tools in science and medicine, offering insights into the functions of biological processes [...].
Collapse
Affiliation(s)
- Danila A. Barskiy
- Institut für Physik, Johannes-Gutenberg-Universität Mainz, 55128 Mainz, Germany;
- Helmholtz Institut Mainz, 55128 Mainz, Germany
- GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt, Germany
| |
Collapse
|
4
|
Ivanova B. Special Issue with Research Topics on "Recent Analysis and Applications of Mass Spectra on Biochemistry". Int J Mol Sci 2024; 25:1995. [PMID: 38396673 PMCID: PMC10888122 DOI: 10.3390/ijms25041995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 02/04/2024] [Indexed: 02/25/2024] Open
Abstract
Analytical mass spectrometry applies irreplaceable mass spectrometric (MS) methods to analytical chemistry and chemical analysis, among other areas of analytical science [...].
Collapse
Affiliation(s)
- Bojidarka Ivanova
- Lehrstuhl für Analytische Chemie, Institut für Umweltforschung, Fakultät für Chemie und Chemische Biologie, Universität Dortmund, Otto-Hahn-Straße 6, 44221 Dortmund, Germany
| |
Collapse
|
5
|
Yan H, Li D, Xu W. A high resolution Fourier transform ion trap enabled by image current splicing: a theoretical study. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:1345-1354. [PMID: 36815265 DOI: 10.1039/d2ay02034c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The relatively high work pressure within an ion trap has limited the implementation of the Fourier transform technique for high resolution mass analysis. The main reason is that high buffer gas pressure will cause the rapid decay of ion oscillations. In this study, an image current splicing method based on the filter diagonalization method (FDM) and the Hilbert transform was developed to increase the resolving power of nondestructive mass analysis in a linear ion trap. First, multiple repeated experiments (or ion trajectory simulations) were performed to collect multiple sets of data. Using the FDM, the frequency component distribution was extracted from short image current transients collected from each experiment. The Hilbert transform was then applied to calculate and normalize the decay envelope of each transient. The relative abundance was calculated by counting the envelopes. Finally, image current transients collected from these multiple experiments were spliced and merged into a whole signal with much longer duration and continuous phase. This splicing method could effectively increase the duration of the image current, and thus improve the mass resolution of the ion trap mass analyzer. The mass resolution (m/Δm) was improved from 183.5 to 5.8 × 103, and the average relative difference was 2.8%. The proposed method resolved 3 adjacent peaks which originally could not be resolved from the raw signal by the fast Fourier transform (FFT). Besides simulated data, this method was also applied to the experimental data collected from a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. The influence of electronic noise on the proposed method was also discussed in this study.
Collapse
Affiliation(s)
- Haoqiang Yan
- College of Computer Science and Engineering, Northeastern University, Shenyang, 110819, China.
| | - Dayu Li
- College of Computer Science and Engineering, Northeastern University, Shenyang, 110819, China.
| | - Wei Xu
- State Key Laboratory of Explosion Science and Technology, School of Life Science, Beijing Institute of Technology, Haidian, Beijing 100081, China.
- Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, Beijing Institute of Technology, Beijing, 100081, China
| |
Collapse
|
6
|
Nagornov KO, Kozhinov AN, Gasilova N, Menin L, Tsybin YO. Characterization of the Time-Domain Isotopic Beat Patterns of Monoclonal Antibodies in Fourier Transform Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:1113-1125. [PMID: 35638743 DOI: 10.1021/jasms.1c00336] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The time-domain transients in the Fourier transform mass spectrometry (FTMS) analysis of monoclonal antibodies (mAbs) are known to exhibit characteristic isotopic beat patterns. These patterns are defined by the isotopic distributions of all gaseous mAb ions present in the FTMS mass analyzer, originating from single or multiple charge states, and from single or multiple proteoforms. For an isolated charge state of a single proteoform, the mAb isotopic beat pattern resembles narrow splashes of signal amplitude (beats), spaced periodically in the time-domain transient, with broad (often exceeding 1 s) "valleys" between them. Here, we reinforce the importance of isotopic beat patterns for the accurate interpretation and presentation of FTMS data in the analysis of mAbs and other large biopolymers. An updated, mAb-grade version of the transient-mediated FTMS data simulation and visualization tool, FTMS Simulator is introduced and benchmarked. We then apply this tool to evaluate the charge-state dependent characteristics of isotopic beats in mAbs analyses with modern models of Orbitrap and ion cyclotron resonance (ICR) FTMS instruments, including detection of higher-order harmonics. We demonstrate the impact of the isotopic beat patterns on the analytical characteristics of the resulting mass spectra of individual and overlapping mAb proteoforms. The results reported here detail highly nonlinear dependences of resolution and signal-to-noise ratio on the time-domain transient period, absorption or magnitude mode spectra representation, and apodization functions. The provided description and the demonstrated ability to routinely conduct accurate simulations of FTMS data for large biopolymers should aid the end-users of Orbitrap and ICR FTMS instruments in the analysis of mAbs and other biopolymers, including viruses.
Collapse
Affiliation(s)
| | | | - Natalia Gasilova
- Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
| | - Laure Menin
- Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
| | | |
Collapse
|
7
|
Shaw JB, Cooper-Shepherd DA, Hewitt D, Wildgoose JL, Beckman JS, Langridge JI, Voinov VG. Enhanced Top-Down Protein Characterization with Electron Capture Dissociation and Cyclic Ion Mobility Spectrometry. Anal Chem 2022; 94:3888-3896. [PMID: 35188751 PMCID: PMC8908312 DOI: 10.1021/acs.analchem.1c04870] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Tandem mass spectrometry of denatured, multiply charged high mass protein precursor ions yield extremely dense spectra with hundreds of broad and overlapping product ion isotopic distributions of differing charge states that yield an elevated baseline of unresolved "noise" centered about the precursor ion. Development of mass analyzers and signal processing methods to increase mass resolving power and manipulation of precursor and product ion charge through solution additives or ion-ion reactions have been thoroughly explored as solutions to spectral congestion. Here, we demonstrate the utility of electron capture dissociation (ECD) coupled with high-resolution cyclic ion mobility spectrometry (cIMS) to greatly increase top-down protein characterization capabilities. Congestion of protein ECD spectra was reduced using cIMS of the ECD product ions and "mobility fractions", that is, extracted mass spectra for segments of the 2D mobiligram (m/z versus drift time). For small proteins, such as ubiquitin (8.6 kDa), where mass resolving power was not the limiting factor for characterization, pre-IMS ECD and mobility fractions did not significantly increase protein sequence coverage, but an increase in the number of identified product ions was observed. However, a dramatic increase in performance, measured by protein sequence coverage, was observed for larger and more highly charged species, such as the +35 charge state of carbonic anhydrase (29 kDa). Pre-IMS ECD combined with mobility fractions yielded a 135% increase in the number of annotated isotope clusters and a 75% increase in unique product ions compared to processing without using the IMS dimension. These results yielded 89% sequence coverage for carbonic anhydrase.
Collapse
Affiliation(s)
- Jared B. Shaw
- e-MSion
Inc., 2121 NE Jack London Street, Corvallis, Oregon 97330, United States, (J.S.)
| | | | - Darren Hewitt
- Waters
Corporation, Wilmslow, Cheshire SK9 4AX, U.K.
| | | | - Joseph S. Beckman
- e-MSion
Inc., 2121 NE Jack London Street, Corvallis, Oregon 97330, United States,Linus
Pauling Institute and the Department of Biochemistry and Biophysics, Oregon State University, Corvallis, Oregon 97331, United States
| | | | - Valery G. Voinov
- e-MSion
Inc., 2121 NE Jack London Street, Corvallis, Oregon 97330, United States
| |
Collapse
|
8
|
Chavez JD, Park SG, Mohr JP, Bruce JE. Applications and advancements of FT-ICR-MS for interactome studies. MASS SPECTROMETRY REVIEWS 2022; 41:248-261. [PMID: 33289940 PMCID: PMC8184889 DOI: 10.1002/mas.21675] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 10/16/2020] [Accepted: 10/16/2020] [Indexed: 05/05/2023]
Abstract
The set of all intra- and intermolecular interactions, collectively known as the interactome, is currently an unmet challenge for any analytical method, but if measured, could provide unparalleled insight on molecular function in living systems. Developments and applications of chemical cross-linking and high-performance mass spectrometry technologies are beginning to reveal details on how proteins interact in cells and how protein conformations and interactions inside cells change with phenotype or during drug treatment or other perturbations. A major contributor to these advances is Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) technology and its implementation with accurate mass measurements on cross-linked peptide-pair precursor and fragment ions to enable improved identification methods. However, these applications place increased demands on mass spectrometer performance in terms of high-resolution spectral acquisition rates for on-line MSn experiments. Moreover, FT-ICR-MS also offers unique opportunities to develop and implement parallel ICR cells for multiplexed signal acquisition and the potential to greatly advance accurate mass acquisition rates for interactome studies. This review highlights our efforts to exploit accurate mass FT-ICR-MS technologies with chemical cross-linking and developments being pursued to realize parallel MS array capabilities that will further advance visualization of the interactome.
Collapse
Affiliation(s)
- Juan D. Chavez
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | - Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | - Jared P. Mohr
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | - James E. Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| |
Collapse
|
9
|
Nagornov KO, Tsybin OY, Nicol E, Kozhinov AN, Tsybin YO. Fourier transform ion cyclotron resonance mass spectrometry at the true cyclotron frequency. MASS SPECTROMETRY REVIEWS 2022; 41:314-337. [PMID: 33462876 DOI: 10.1002/mas.21681] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 12/24/2020] [Accepted: 12/26/2020] [Indexed: 06/12/2023]
Abstract
Ion cyclotron resonance (ICR) cells provide stability and coherence of ion oscillations in crossed electric and magnetic fields over extended periods of time. Using the Fourier transform enables precise measurements of ion oscillation frequencies. These precisely measured frequencies are converted into highly accurate mass-to-charge ratios of the analyte ions by calibration procedures. In terms of resolution and mass accuracy, Fourier transform ICR mass spectrometry (FT-ICR MS) offers the highest performance of any MS technology. This is reflected in its wide range of applications. However, in the most challenging MS application, for example, imaging, enhancements in the mass accuracy of fluctuating ion fluxes are required to continue advancing the field. One approach is to shift the ion signal power into the peak corresponding to the true cyclotron frequency instead of the reduced cyclotron frequency peak. The benefits of measuring the true cyclotron frequency include increased tolerance to electric fields within the ICR cell, which enhances frequency measurement precision. As a result, many attempts to implement this mode of FT-ICR MS operation have occurred. Examples of true cyclotron frequency measurements include detection of magnetron inter-harmonics of the reduced cyclotron frequency (i.e., the sidebands), trapping field-free (i.e., screened) ICR cells, and hyperbolic ICR cells with quadrupolar ion detection. More recently, ICR cells with spatially distributed ion clouds have demonstrated attractive performance characteristics for true cyclotron frequency ion detection. Here, we review the corresponding developments in FT-ICR MS over the past 40 years.
Collapse
Affiliation(s)
| | - Oleg Y Tsybin
- Ion Physics and Mass Spectrometry Laboratory, Peter The Great State Polytechnic University, Saint-Petersburg, Russia
| | - Edith Nicol
- Laboratoire de Chimie Moléculaire, CNRS, UMR 9168, Ecole Polytechnique, Institut Polytechnique de Paris, Palaiseau, France
| | | | | |
Collapse
|
10
|
Li C, Chu S, Tan S, Yin X, Jiang Y, Dai X, Gong X, Fang X, Tian D. Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers. Front Chem 2021; 9:813359. [PMID: 34993180 PMCID: PMC8724130 DOI: 10.3389/fchem.2021.813359] [Citation(s) in RCA: 58] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 12/06/2021] [Indexed: 01/12/2023] Open
Abstract
Mass spectrometry (MS) is one of the most widely used analytical techniques in many fields. Recent developments in chemical and biological researches have drawn much attention to the measurement of substances with low abundances in samples. Continuous efforts have been made consequently to further improve the sensitivity of MS. Modifications on the mass analyzers of mass spectrometers offer a direct, universal and practical way to obtain higher sensitivity. This review provides a comprehensive overview of the latest developments in mass analyzers for the improvement of mass spectrometers' sensitivity, including quadrupole, ion trap, time-of-flight (TOF) and Fourier transform ion cyclotron (FT-ICR), as well as different combinations of these mass analyzers. The advantages and limitations of different mass analyzers and their combinations are compared and discussed. This review provides guidance to the selection of suitable mass spectrometers in chemical and biological analytical applications. It is also beneficial to the development of novel mass spectrometers.
Collapse
Affiliation(s)
- Chang Li
- College of Instrumentation & Electrical Engineering, Jilin University, Changchun, China
| | - Shiying Chu
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People’s Republic ofChina
| | - Siyuan Tan
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People’s Republic ofChina
| | - Xinchi Yin
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People’s Republic ofChina
| | - You Jiang
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People’s Republic ofChina
| | - Xinhua Dai
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People’s Republic ofChina
| | - Xiaoyun Gong
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People’s Republic ofChina
| | - Xiang Fang
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People’s Republic ofChina
| | - Di Tian
- College of Instrumentation & Electrical Engineering, Jilin University, Changchun, China
| |
Collapse
|
11
|
Maia M, Figueiredo A, Cordeiro C, Sousa Silva M. FT-ICR-MS-based metabolomics: A deep dive into plant metabolism. MASS SPECTROMETRY REVIEWS 2021. [PMID: 34545595 DOI: 10.1002/mas.21731] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 08/30/2021] [Accepted: 09/09/2021] [Indexed: 06/13/2023]
Abstract
Metabolomics involves the identification and quantification of metabolites to unravel the chemical footprints behind cellular regulatory processes and to decipher metabolic networks, opening new insights to understand the correlation between genes and metabolites. In plants, it is estimated the existence of hundreds of thousands of metabolites and the majority is still unknown. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) is a powerful analytical technique to tackle such challenges. The resolving power and sensitivity of this ultrahigh mass accuracy mass analyzer is such that a complex mixture, such as plant extracts, can be analyzed and thousands of metabolite signals can be detected simultaneously and distinguished based on the naturally abundant elemental isotopes. In this review, FT-ICR-MS-based plant metabolomics studies are described, emphasizing FT-ICR-MS increasing applications in plant science through targeted and untargeted approaches, allowing for a better understanding of plant development, responses to biotic and abiotic stresses, and the discovery of new natural nutraceutical compounds. Improved metabolite extraction protocols compatible with FT-ICR-MS, metabolite analysis methods and metabolite identification platforms are also explored as well as new in silico approaches. Most recent advances in MS imaging are also discussed.
Collapse
Affiliation(s)
- Marisa Maia
- Departamento de Química e Bioquímica, Laboratório de FTICR e Espectrometria de Massa Estrutural, MARE-Marine and Environmental Sciences Centre, Faculdade de Ciências, Universidade de Lisboa, Lisboa, Portugal
- Departamento de Biologia Vegetal, Faculdade de Ciências, Grapevine Pathogen Systems Lab (GPS Lab), Biosystems and Integrative Sciences Institute (BioISI), Universidade de Lisboa, Lisboa, Portugal
| | - Andreia Figueiredo
- Departamento de Biologia Vegetal, Faculdade de Ciências, Grapevine Pathogen Systems Lab (GPS Lab), Biosystems and Integrative Sciences Institute (BioISI), Universidade de Lisboa, Lisboa, Portugal
| | - Carlos Cordeiro
- Departamento de Química e Bioquímica, Laboratório de FTICR e Espectrometria de Massa Estrutural, MARE-Marine and Environmental Sciences Centre, Faculdade de Ciências, Universidade de Lisboa, Lisboa, Portugal
| | - Marta Sousa Silva
- Departamento de Química e Bioquímica, Laboratório de FTICR e Espectrometria de Massa Estrutural, MARE-Marine and Environmental Sciences Centre, Faculdade de Ciências, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
12
|
Huang D, Bouza M, Gaul DA, Leach FE, Amster IJ, Schroeder FC, Edison AS, Fernández FM. Comparison of High-Resolution Fourier Transform Mass Spectrometry Platforms for Putative Metabolite Annotation. Anal Chem 2021; 93:12374-12382. [PMID: 34460220 PMCID: PMC8590398 DOI: 10.1021/acs.analchem.1c02224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Fourier transform ion cyclotron resonance (FT-ICR) and Orbitrap mass spectrometry (MS) are among the highest-performing analytical platforms used in metabolomics. Non-targeted metabolomics experiments, however, yield extremely complex datasets that make metabolite annotation very challenging and sometimes impossible. The high-resolution accurate mass measurements of the leading MS platforms greatly facilitate this process by reducing mass errors and spectral overlaps. When high resolution is combined with relative isotopic abundance (RIA) measurements, heuristic rules, and constraints during searches, the number of candidate elemental formula(s) can be significantly reduced. Here, we evaluate the performance of Orbitrap ID-X and 12T solariX FT-ICR mass spectrometers in terms of mass accuracy and RIA measurements and how these factors affect the assignment of the correct elemental formulas in the metabolite annotation pipeline. Quality of the mass measurements was evaluated under various experimental conditions (resolution: 120, 240, 500 K; automatic gain control: 5 × 104, 1 × 105, 5 × 105) for the Orbitrap MS platform. High average mass accuracy (<1 ppm for UPLC-Orbitrap MS and <0.2 ppm for direct infusion FT-ICR MS) was achieved and allowed the assignment of correct elemental formulas for over 90% (m/z 75-466) of the 104 investigated metabolites. 13C1 and 18O1 RIA measurements further improved annotation certainty by reducing the number of candidates. Overall, our study provides a systematic evaluation for two leading Fourier transform (FT)-based MS platforms utilized in metabolite annotation and provides the basis for applying these, individually or in combination, to metabolomics studies of biological systems.
Collapse
Affiliation(s)
- Danning Huang
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Marcos Bouza
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - David A Gaul
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Franklin E Leach
- Department of Environmental Health Science, University of Georgia, Athens, Georgia 30602, United States
| | - I Jonathan Amster
- Department of Chemistry, University of Georgia, Athens, Georgia 30602, United States
| | - Frank C Schroeder
- Boyce Thompson Institute and Department to Chemistry and Chemical Biology, Cornell University, Ithaca, New York 14853, United States
| | - Arthur S Edison
- Departments of Genetics and Biochemistry and Molecular Biology, Complex Carbohydrate Research Center, University of Georgia, Athens, Georgia 30602, United States
| | - Facundo M Fernández
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
13
|
Park SG, Mohr JP, Anderson GA, Bruce JE. Application of frequency multiple FT-ICR-MS signal acquisition for improved proteome research. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2021; 465:116578. [PMID: 33897275 PMCID: PMC8059610 DOI: 10.1016/j.ijms.2021.116578] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled with liquid chromatography (LC) is a powerful combination useful in many research areas due to the utility of high mass resolving power and mass measurement accuracy for studying highly complex samples. Ideally, every analyte in a complex sample can be subjected to accurate mass MS/MS analysis to aid in identification. FT-ICR MS can provide high mass resolving power and mass accuracy at the cost of long data acquisition periods, reducing the number of spectra that can be acquired per unit time. Frequency multiple signal acquisition has long been realized as an attractive method to obtain high mass resolving power and mass accuracy with shorter data acquisition periods. However, one of the limitations associated with frequency multiple signal acquisition is reduced signal intensity as compared to a traditional dipole detector. In this study, we demonstrated the use of a novel ICR cell to improve frequency multiple signal intensity and investigated the potential use of frequency multiple acquisition for proteome measurements. This novel ICR cell containing both dipole and frequency multiple detection electrodes was installed on a 7T FT-ICR MS coupled to an LC system. Tryptic digests of HeLa cell lysates were analyzed using dipole and frequency multiple detectors by holding either the mass resolving power or signal acquisition time constant. Compared to dipole detection, second frequency multiple detection yielded 36% or 45% more unique identified peptides from HeLa cell lysates at twice the scan rate or twice the mass resolving power, respectively. These results indicate that frequency multiple signal acquisition with either the same resolving power or the same signal acquisition duration as used with dipole signals can produce a significant increase in the number of peptides identified in complex proteome samples.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | - Jared P Mohr
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | | | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| |
Collapse
|
14
|
Xie YR, Castro DC, Lam F, Sweedler JV. Accelerating Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry Imaging Using a Subspace Approach. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2338-2347. [PMID: 33064944 PMCID: PMC7682253 DOI: 10.1021/jasms.0c00276] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
We present a subspace method that accelerates data acquisition using Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometry imaging (MSI). For MSI of biological tissue samples, there is a finite number of heterogeneous tissue types with distinct chemical profiles that introduce redundancy in the high-dimensional measurements. Our subspace model exploits the redundancy in data measured from whole-slice tissue samples by decomposing the transient signals into linear combinations of a set of basis transients with the desired spectral resolution. This decomposition allowed us to design a strategy that acquires a subset of long transients for basis determination and short transients for the remaining pixels, drastically reducing the acquisition time. The computational reconstruction strategy can maintain high-mass-resolution and spatial-resolution MSI while providing a 10-fold improvement in throughput. We validated the capability of the subspace model using a rat sagittal brain slice imaging data set. Comprehensive evaluation of the quality of the mass spectral and ion images demonstrated that the reconstructed data produced by the reported method required only 15% of the typical acquisition time and exhibited both qualitative and quantitative consistency when compared to the original data. Our method enables either higher sample throughput or higher-resolution images at similar acquisition lengths, providing greater flexibility in obtaining FT-ICR MSI measurements.
Collapse
Affiliation(s)
- Yuxuan Richard Xie
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801
| | - Daniel C. Castro
- Department of Molecular and Integrative Physiology, University of Illinois at Urbana-Champaign, Urbana, IL 61801
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801
| | - Fan Lam
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801
- Corresponding Authors: Fan Lam, Postal: 405 N. Mathews Avenue, Urbana, IL 61801, , Jonathan V. Sweedler, Postal: 600 S. Mathews Avenue, Urbana, IL 61801,
| | - Jonathan V. Sweedler
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801
- Department of Molecular and Integrative Physiology, University of Illinois at Urbana-Champaign, Urbana, IL 61801
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL 61801
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801
- Corresponding Authors: Fan Lam, Postal: 405 N. Mathews Avenue, Urbana, IL 61801, , Jonathan V. Sweedler, Postal: 600 S. Mathews Avenue, Urbana, IL 61801,
| |
Collapse
|
15
|
Nagornov KO, Kozhinov AN, Nicol E, Tsybin OY, Touboul D, Brunelle A, Tsybin YO. Narrow Aperture Detection Electrodes ICR Cell with Quadrupolar Ion Detection for FT-ICR MS at the Cyclotron Frequency. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2258-2269. [PMID: 32966078 DOI: 10.1021/jasms.0c00221] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Ion signal detection at the true (unperturbed) cyclotron frequency instead of the conventional reduced cyclotron frequency has remained a formidable challenge since the inception of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Recently, routine FT-ICR MS at the true cyclotron frequency has become a reality with the implementation of ICR cells with narrow aperture detection electrodes (NADEL). Here, we describe the development and implementation of the next generation of these cells, namely, a 2xNADEL ICR cell, which comprises four flat detect and four ∼45° cylindrical excite electrodes, enabling independent ion excitation and quadrupolar ion detection. The performance of the 2xNADEL ICR cell was evaluated on two commercial FT-ICR MS platforms, 10 T LTQ FT from Thermo Scientific and 9.4 T SolariX XR from Bruker Daltonics. The cells provided accurate mass measurements in the analyses of singly and multiply charged peptides (root-mean-square, RMS, mass error Δm/m of 90 ppb), proteins (Δm/m = 200 ppb), and petroleum fractions (Δm/m < 200 ppb). Due to the reduced influence of measured frequency on the space charge and external (trapping) electric fields, the 2xNADEL ICR cells exhibited stable performance in a wide range of trapping potentials (1-20 V). Similarly, in a 13 h rat brain MALDI imaging experiment, the RMS mass error did not exceed 600 ppb even for low signal-to-noise ratio analyte peaks. Notably, the same set of calibration constants was applicable to Fourier spectra in all pixels, reducing the need for recalibration at the individual pixel level. Overall, these results support further experimental development and fundamentals investigation of this promising technology.
Collapse
Affiliation(s)
| | | | - Edith Nicol
- Laboratoire de Chimie Moléculaire, CNRS UMR 9168, Ecole Polytechnique, Institut Polytechnique de Paris, 91128 Palaiseau, France
| | - Oleg Yu Tsybin
- Peter the Great Saint Petersburg Polytechnic University, 195251 St. Petersburg, Russia
| | - David Touboul
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198 Gif-sur-Yvette, France
| | - Alain Brunelle
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198 Gif-sur-Yvette, France
- Laboratoire d'Archéologie Moléculaire et Structurale, LAMS UMR8220, CNRS, Sorbonne Université, 4 Place Jussieu, 75005 Paris, France
| | - Yury O Tsybin
- Spectroswiss, EPFL Innovation Park, 1015 Lausanne, Switzerland
| |
Collapse
|
16
|
Park SG, Anderson GA, Bruce JE. Parallel Detection of Fundamental and Sixth Harmonic Signals Using an ICR Cell with Dipole and Sixth Harmonic Detectors. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:719-726. [PMID: 31967815 PMCID: PMC7970440 DOI: 10.1021/jasms.9b00144] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is a powerful instrument for high-resolution analysis of biomolecules. However, relatively long signal acquisition periods are needed to achieve mass spectra with high resolution. The use of multiple detector electrodes for detection of harmonic frequencies has been introduced as one approach to increase scan rate for a given resolving power or to obtain increased resolving power for a given detection period. The achieved resolving power and scan rate increase linearly with the order of detected harmonic signals. In recent years, ICR cell geometries have been investigated to increase the order of the harmonic frequencies and enhance harmonic signal intensities. In this study, we demonstrated PCB-based ICR cell designs with dipole and sixth harmonic detectors for parallel detection of fundamental and harmonic (6f) signals. The sixth harmonic signals from the sixth harmonic detector showed an expected 6 times higher resolving power with (M + 3H)3+ charge state insulin ions as compared with that from fundamental signals from the dipole detector. Moreover, the insulin isotopic peaks with sixth harmonic frequency signals acquired with the sixth harmonic detector were resolved for a 40 ms data acquisition period but unresolved with the same duration dipole detector signals, corresponding to a 6-fold improvement in achievable spectral acquisition rates for a given resolving power.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, Washington 98109, United States
| | - Gordon A Anderson
- GAA Custom Engineering, LLC, Benton City, Washington 99320, United States
| | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, Washington 98109, United States
| |
Collapse
|
17
|
Yap T, Celentano A, Seers C, McCullough MJ, Farah CS. Molecular diagnostics in oral cancer and oral potentially malignant disorders-A clinician's guide. J Oral Pathol Med 2019; 49:1-8. [PMID: 31309636 DOI: 10.1111/jop.12920] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2019] [Revised: 06/03/2019] [Accepted: 06/14/2019] [Indexed: 12/14/2022]
Abstract
Current risk stratification of individuals for the development of oral squamous cell carcinoma (OSCC), including those with oral potentially malignant disorders (OPMD), remains based on clinical detection of visibly abnormal mucosa and tissue biopsy with histological assessment for the presence of OSCC or oral epithelial dysplasia (OED). In OPMD, the presence of OED remains the only prognostic tool used in standard care for the development of future OSCC, despite its ample limitations. There is assured potential that the analysis of the genome, transcripts and proteome can provide insight into what is occurring at a cellular level preceding the appearance of clinically observable change. The landscape of the role of the genome and its transcriptome on the development of OSCC and relationships with OPMDs are immense with exploration occurring on several fronts. For clinicians involved in the diagnosis and care of patients with OSCC and OPMD, understanding of commonly used molecular diagnostic techniques is imperative to gain useful insight from the expanding literature investigating the development of OSCC and the relationship with the clinical presentations which encompass OPMDs. Here we present an introduction to molecular diagnostic methods used in the study of OSCC and OPMD.
Collapse
Affiliation(s)
- Tami Yap
- Melbourne Dental School, University of Melbourne, Melbourne, Victoria, Australia
| | - Antonio Celentano
- Melbourne Dental School, University of Melbourne, Melbourne, Victoria, Australia
| | - Christine Seers
- Melbourne Dental School, University of Melbourne, Melbourne, Victoria, Australia
| | - Michael J McCullough
- Melbourne Dental School, University of Melbourne, Melbourne, Victoria, Australia
| | - Camile S Farah
- Melbourne Dental School, University of Melbourne, Melbourne, Victoria, Australia.,Australian Centre for Oral Oncology Research & Education, Nedlands, Western Australia, Australia
| |
Collapse
|
18
|
Ding L, Rusinov A. High-Capacity Electrostatic Ion Trap with Mass Resolving Power Boosted by High-Order Harmonics. Anal Chem 2019; 91:7595-7602. [DOI: 10.1021/acs.analchem.9b00206] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Li Ding
- Shimadzu Research Laboratory (Europe) Limited, Wharfside, Trafford Wharf Road, Manchester, M17 1GP, U.K
| | - Aleksandr Rusinov
- Shimadzu Research Laboratory (Europe) Limited, Wharfside, Trafford Wharf Road, Manchester, M17 1GP, U.K
| |
Collapse
|
19
|
Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches. Sci Rep 2019; 9:8. [PMID: 30626890 PMCID: PMC6327097 DOI: 10.1038/s41598-018-36957-1] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2018] [Accepted: 11/28/2018] [Indexed: 12/20/2022] Open
Abstract
Desorption electrospray ionisation-mass spectrometry imaging (DESI-MSI) is a powerful imaging technique for the analysis of complex surfaces. However, the often highly complex nature of biological samples is particularly challenging for MSI approaches, as options to appropriately address molecular complexity are limited. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) offers superior mass accuracy and mass resolving power, but its moderate throughput inhibits broader application. Here we demonstrate the dramatic gains in mass resolution and/or throughput of DESI-MSI on an FT-ICR MS by developing and implementing a sophisticated data acquisition and data processing pipeline. The presented pipeline integrates, for the first time, parallel ion accumulation and detection, post-processing absorption mode Fourier transform and pixel-by-pixel internal re-calibration. To achieve that, first, we developed and coupled an external high-performance data acquisition system to an FT-ICR MS instrument to record the time-domain signals (transients) in parallel with the instrument’s built-in electronics. The recorded transients were then processed by the in-house developed computationally-efficient data processing and data analysis software. Importantly, the described pipeline is shown to be applicable even to extremely large, up to 1 TB, imaging datasets. Overall, this approach provides improved analytical figures of merits such as: (i) enhanced mass resolution at no cost in experimental time; and (ii) up to 4-fold higher throughput while maintaining a constant mass resolution. Using this approach, we not only demonstrate the record 1 million mass resolution for lipid imaging from brain tissue, but explicitly show such mass resolution is required to resolve the complexity of the lipidome.
Collapse
|
20
|
Park SG, Anderson GA, Bruce JE. Characterization of Harmonic Signal Acquisition with Parallel Dipole and Multipole Detectors. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:1394-1402. [PMID: 29691781 PMCID: PMC6537869 DOI: 10.1007/s13361-018-1954-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 03/01/2018] [Accepted: 03/21/2018] [Indexed: 05/22/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is a powerful instrument for the study of complex biological samples due to its high resolution and mass measurement accuracy. However, the relatively long signal acquisition periods needed to achieve high resolution can serve to limit applications of FTICR-MS. The use of multiple pairs of detector electrodes enables detection of harmonic frequencies present at integer multiples of the fundamental cyclotron frequency, and the obtained resolving power for a given acquisition period increases linearly with the order of harmonic signal. However, harmonic signal detection also increases spectral complexity and presents challenges for interpretation. In the present work, ICR cells with independent dipole and harmonic detection electrodes and preamplifiers are demonstrated. A benefit of this approach is the ability to independently acquire fundamental and multiple harmonic signals in parallel using the same ions under identical conditions, enabling direct comparison of achieved performance as parameters are varied. Spectra from harmonic signals showed generally higher resolving power than spectra acquired with fundamental signals and equal signal duration. In addition, the maximum observed signal to noise (S/N) ratio from harmonic signals exceeded that of fundamental signals by 50 to 100%. Finally, parallel detection of fundamental and harmonic signals enables deconvolution of overlapping harmonic signals since observed fundamental frequencies can be used to unambiguously calculate all possible harmonic frequencies. Thus, the present application of parallel fundamental and harmonic signal acquisition offers a general approach to improve utilization of harmonic signals to yield high-resolution spectra with decreased acquisition time. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA, 98109, USA
| | | | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA, 98109, USA.
| |
Collapse
|
21
|
Shaw JB, Gorshkov MV, Wu Q, Paša-Tolić L. High Speed Intact Protein Characterization Using 4X Frequency Multiplication, Ion Trap Harmonization, and 21 Tesla FTICR-MS. Anal Chem 2018; 90:5557-5562. [PMID: 29613776 DOI: 10.1021/acs.analchem.7b04606] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Mass spectrometric characterization of large biomolecules, such as intact proteins, requires the specificity afforded by ultrahigh resolution mass measurements performed at both the intact mass and product ion levels. Although the performance of time-of-flight mass analyzers is steadily increasing, the choice of mass analyzer for large biomolecules (e.g., proteins >50 kDa) is generally limited to the Fourier transform family of mass analyzers such as Orbitrap and ion cyclotron resonance (FTICR-MS), with the latter providing unmatched mass resolving power and measurement accuracy. Yet, protein analyses using FTMS are largely hindered by the low acquisition rates of spectra with ultrahigh resolving power. Frequency multiple detection schemes enable FTICR-MS to overcome this fundamental barrier and achieve resolving powers and acquisition speeds 4× greater than the limits imposed by magnetic field strength. Here we expand upon earlier work on the implementation of this technique for biomolecular characterization. We report the coupling of 21T FTICR-MS, 4X frequency multiplication, ion trapping field harmonization technology, and spectral data processing methods to achieve unprecedented acquisition rates and resolving power in mass spectrometry of large intact proteins. Isotopically resolved spectra of multiply charged ubiquitin ions were acquired using detection periods as short as 12 ms. Large proteins such as apo-transferrin (MW = 78 kDa) and monoclonal antibody (MW = 150 kDa) were isotopically resolved with detection periods of 384 and 768 ms, respectively. These results illustrate the future capability of accurate characterization of large proteins on time scales compatible with online separations.
Collapse
Affiliation(s)
- Jared B Shaw
- Environmental Molecular Sciences Laboratory , Pacific Northwest National Laboratory , 3335 Innovation Boulevard . Richland , Washington 99352 , United States
| | - Mikhail V Gorshkov
- V.L. Talrose Institute for Energy Problems of Chemical Physics , Russian Academy of Sciences , Moscow 119334 , Russia.,Moscow Institute of Physics and Technology (State University) , Dolgoprudny , Moscow Region 141700 , Russia
| | - Qinghao Wu
- Environmental Molecular Sciences Laboratory , Pacific Northwest National Laboratory , 3335 Innovation Boulevard . Richland , Washington 99352 , United States
| | - Ljiljana Paša-Tolić
- Environmental Molecular Sciences Laboratory , Pacific Northwest National Laboratory , 3335 Innovation Boulevard . Richland , Washington 99352 , United States
| |
Collapse
|
22
|
Park SG, Anderson GA, Bruce JE. Parallel detection in a single ICR cell: Spectral averaging and improved S/N without increased acquisition time. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2018; 427:29-34. [PMID: 29731686 PMCID: PMC5931402 DOI: 10.1016/j.ijms.2017.08.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is well-renowned for its ultrahigh resolving power and mass measurement accuracy. As with other types of analytical instrumentation, achievable signal-to-noise ratio (S/N) is an important analytical figure of merit with FTICR-MS. S/N can be improved with higher magnetic fields and longer time-domain signal acquisition periods. However, serial signal averaging of spectra or time-domain signals acquired with multiple ion populations is most commonly used to improve S/N. On the other hand, serial acquisition and averaging of multiple scans significantly increases required data acquisition time and is often incompatible with on-line chromatographic separations. In this study, we investigated the potential for increased S/N by averaging 4 spectra that were acquired in parallel with a single ICR cell with 4 pairs of dipole detection electrodes, each with an independent pre-amplifier. This spectral averaging was achieved with no need for multiple ion accumulation events nor multiple, serial excitation and detection events. These efforts demonstrated that parallel signal acquisition with 4 detector electrode pairs produces S/N 1.76-fold higher than that from a single detection electrode pair. With parallel detection, improved S/N was achieved with no observable loss in resolving power (100,000) as compared with that from a single detection electrode pair. These results demonstrate that parallel detection of multiple induced image current signals with multiple preamplifiers exists as a viable option for future instrumentation to increase achievable S/N and sensitivity. This approach may have general utility especially where conventional serial signal averaging is impractical.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | | | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| |
Collapse
|
23
|
Zhou M, Yan J, Romano CA, Tebo BM, Wysocki VH, Paša-Tolić L. Surface Induced Dissociation Coupled with High Resolution Mass Spectrometry Unveils Heterogeneity of a 211 kDa Multicopper Oxidase Protein Complex. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:723-733. [PMID: 29388167 PMCID: PMC7305857 DOI: 10.1007/s13361-017-1882-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2017] [Revised: 12/22/2017] [Accepted: 12/22/2017] [Indexed: 05/11/2023]
Abstract
Manganese oxidation is an important biogeochemical process that is largely regulated by bacteria through enzymatic reactions. However, the detailed mechanism is poorly understood due to challenges in isolating and characterizing these unknown enzymes. A manganese oxidase, Mnx, from Bacillus sp. PL-12 has been successfully overexpressed in active form as a protein complex with a molecular mass of 211 kDa. We have recently used surface induced dissociation (SID) and ion mobility-mass spectrometry (IM-MS) to release and detect folded subcomplexes for determining subunit connectivity and quaternary structure. The data from the native mass spectrometry experiments led to a plausible structural model of this multicopper oxidase, which has been difficult to study by conventional structural biology methods. It was also revealed that each Mnx subunit binds a variable number of copper ions. Becasue of the heterogeneity of the protein and limited mass resolution, ambiguities in assigning some of the observed peaks remained as a barrier to fully understanding the role of metals and potential unknown ligands in Mnx. In this study, we performed SID in a modified Fourier transform-ion cyclotron resonance (FTICR) mass spectrometer. The high mass accuracy and resolution offered by FTICR unveiled unexpected artificial modifications on the protein that had been previously thought to be iron bound species based on lower resolution spectra. Additionally, isotopically resolved spectra of the released subcomplexes revealed the metal binding stoichiometry at different structural levels. This method holds great potential for in-depth characterization of metalloproteins and protein-ligand complexes. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Mowei Zhou
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Blvd, Richland, WA, 99354, USA
| | - Jing Yan
- Department of Chemistry and Biochemistry, Ohio State University, 460 W 12th Ave, Columbus, OH, 43210, USA
| | - Christine A Romano
- Division of Environmental and Biomolecular Systems, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 97239, USA
| | - Bradley M Tebo
- Division of Environmental and Biomolecular Systems, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Portland, OR, 97239, USA
| | - Vicki H Wysocki
- Department of Chemistry and Biochemistry, Ohio State University, 460 W 12th Ave, Columbus, OH, 43210, USA
| | - Ljiljana Paša-Tolić
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Blvd, Richland, WA, 99354, USA.
| |
Collapse
|
24
|
Liu X, Xu G. Recent advances in using mass spectrometry for mitochondrial metabolomics and lipidomics - A review. Anal Chim Acta 2017; 1037:3-12. [PMID: 30292306 DOI: 10.1016/j.aca.2017.11.080] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2017] [Revised: 11/28/2017] [Accepted: 11/29/2017] [Indexed: 01/09/2023]
Abstract
Metabolomics and lipidomics generally targets a huge number of intermediate and end products of cellular metabolism in body fluids, tissues, and cells etc. At present, mass spectrometry (MS) based metabolic or lipid profiling of routine biological specimens including the whole cells, tissues, plasma, serum and urine etc., can cover hundreds of metabolites or lipid species in one analysis, which has qualified deep elucidation of global metabolic and lipid networks. Mitochondria are important intracellular organelles and many critical biochemical reactions occur here, they provide building block for new cells, control redox balance, participate in apoptosis and behave as a signalling platform. Evidence suggests high prevalence of mitochondrial dysfunction occurs in a variety of cancers and other diseases, thus there is an urgent demand for investigating and clarifying mitochondrial metabolic and lipid alterations induced by diseases. Nevertheless, mitochondria contribute a small fraction to cellular contents, profiling of whole cell is probably unsuitable for monitoring alterations in mitochondria. Therefore, metabolomics and lipidomics analyses specially for mitochondria are necessary to understand disturbed metabolic and lipid pathways induced by environment and diseases. However, methods for comprehensively profiling metabolites and lipids in mitochondria have been limited at present. This review summarizes the current states and progress of MS-based mitochondrial metabolomics and lipidomics study. Details of mitochondrial isolation procedure, analytical methods and their applications are described. The challenges and opportunities are also given.
Collapse
Affiliation(s)
- Xinyu Liu
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Guowang Xu
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| |
Collapse
|
25
|
Dodds JN, May JC, McLean JA. Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry. Anal Chem 2017; 89:12176-12184. [PMID: 29039942 PMCID: PMC5744666 DOI: 10.1021/acs.analchem.7b02827] [Citation(s) in RCA: 134] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Here we examine the relationship among resolving power (Rp), resolution (Rpp), and collision cross section (CCS) for compounds analyzed in previous ion mobility (IM) experiments representing a wide variety of instrument platforms and IM techniques. Our previous work indicated these three variables effectively describe and predict separation efficiency for drift tube ion mobility spectrometry experiments. In this work, we seek to determine if our previous findings are a general reflection of IM behavior that can be applied to various instrument platforms and mobility techniques. Results suggest IM distributions are well characterized by a Gaussian model and separation efficiency can be predicted on the basis of the empirical difference in the gas-phase CCS and a CCS-based resolving power definition (CCS/ΔCCS). Notably traveling wave (TWIMS) was found to operate at resolutions substantially higher than a single-peak resolving power suggested. When a CCS-based Rp definition was utilized, TWIMS was found to operate at a resolving power between 40 and 50, confirming the previous observations by Giles and co-workers. After the separation axis (and corresponding resolving power) is converted to cross section space, it is possible to effectively predict separation behavior for all mobility techniques evaluated (i.e., uniform field, trapped ion mobility, traveling wave, cyclic, and overtone instruments) using the equations described in this work. Finally, we are able to establish for the first time that the current state-of-the-art ion mobility separations benchmark at a CCS-based resolving power of >300 that is sufficient to differentiate analyte ions with CCS differences as small as 0.5%.
Collapse
Affiliation(s)
| | | | - John A. McLean
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville Tennessee 37235, United States
| |
Collapse
|
26
|
Cho E, Witt M, Hur M, Jung MJ, Kim S. Application of FT-ICR MS Equipped with Quadrupole Detection for Analysis of Crude Oil. Anal Chem 2017; 89:12101-12107. [DOI: 10.1021/acs.analchem.7b02644] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Eunji Cho
- Department
of Chemistry, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu 41566, Republic of Korea
| | - Matthias Witt
- Bruker Daltonik
GmbH, Fahrenheitrasse 4, 28359 Bremen, Germany
| | - Manhoi Hur
- Department
of Genetics, Development, and Cell Biology, Iowa State University, Ames, Iowa 50011, United States
- Center
for Metabolic Biology, Iowa State University, Ames, Iowa 50011, United States
| | - Maeng-Joon Jung
- Department
of Chemistry, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu 41566, Republic of Korea
| | - Sunghwan Kim
- Department
of Chemistry, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu 41566, Republic of Korea
- Green-Nano Materials
Research Center, Daegu 41566, Republic of Korea
| |
Collapse
|
27
|
Park SG, Anderson GA, Bruce JE. Parallel Spectral Acquisition with Orthogonal ICR Cells. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:515-524. [PMID: 28058592 PMCID: PMC5352489 DOI: 10.1007/s13361-016-1573-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 11/21/2016] [Accepted: 11/27/2016] [Indexed: 05/22/2023]
Abstract
FT-based high performance mass analyzers yield increased resolving power and mass measurement accuracy, yet require increased duration of signal acquisition that can limit many applications. The implementation of stronger magnetic fields, multiple detection electrodes for harmonic signal detection, and an array of multiple mass analyzers arranged along the magnetic field axis have been used to decrease required acquisition time. The results presented here show that multiple ion cyclotron resonance (ICR) mass analyzers can also be implemented orthogonal to the central magnetic field axis. The orthogonal ICR cell system presented here consisting of two cells (master and slave cells) was constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. A master cell was positioned, as is normally done with ICR cells, on the central magnetic field axis and a slave cell was located off this central axis, but directly adjacent and alongside the master cell. To achieve ion transfer between cells, ions that were initially trapped in the master cell were drifted across the magnetic field into the slave cell with application of a small DC field applied perpendicularly to the magnetic field axis. A subsequent population of ions was injected and accumulated in the master cell. Simultaneous excitation of cyclotron motion of ions in both cells was carried out; ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition with this orthogonal dual ICR cell array. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA, 98109, USA
| | | | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA, 98109, USA.
| |
Collapse
|
28
|
Shaw JB, Lin TY, Leach FE, Tolmachev AV, Tolić N, Robinson EW, Koppenaal DW, Paša-Tolić L. 21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer Greatly Expands Mass Spectrometry Toolbox. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:1929-1936. [PMID: 27734325 DOI: 10.1007/s13361-016-1507-9] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Revised: 09/12/2016] [Accepted: 09/13/2016] [Indexed: 06/06/2023]
Abstract
We provide the initial performance evaluation of a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer operating at the Environmental Molecular Sciences Laboratory at the Pacific Northwest National Laboratory. The spectrometer constructed for the 21T system employs a commercial dual linear ion trap mass spectrometer coupled to a FTICR spectrometer designed and built in-house. Performance gains from moving to higher magnetic field strength are exemplified by the measurement of peptide isotopic fine structure, complex natural organic matter mixtures, and large proteins. Accurate determination of isotopic fine structure was demonstrated for doubly charged Substance P with minimal spectral averaging, and 8158 molecular formulas assigned to Suwannee River Fulvic Acid standard with root-mean-square (RMS) error of 10 ppb. We also demonstrated superior performance for intact proteins; namely, broadband isotopic resolution of the entire charge state distribution of apo-transferrin (78 kDa) and facile isotopic resolution of monoclonal antibody under a variety of acquisition parameters (e.g., 6 s time-domains with absorption mode processing yielded resolution of approximately 1 M at m/z = 2700). Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Jared B Shaw
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Ave. (K8-98), P.O. Box 999, Richland, WA, 99352, USA
| | - Tzu-Yung Lin
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Ave. (K8-98), P.O. Box 999, Richland, WA, 99352, USA
| | - Franklin E Leach
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Ave. (K8-98), P.O. Box 999, Richland, WA, 99352, USA
| | - Aleksey V Tolmachev
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Ave. (K8-98), P.O. Box 999, Richland, WA, 99352, USA
| | - Nikola Tolić
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Ave. (K8-98), P.O. Box 999, Richland, WA, 99352, USA
| | - Errol W Robinson
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Ave. (K8-98), P.O. Box 999, Richland, WA, 99352, USA
| | - David W Koppenaal
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Ave. (K8-98), P.O. Box 999, Richland, WA, 99352, USA
| | - Ljiljana Paša-Tolić
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Ave. (K8-98), P.O. Box 999, Richland, WA, 99352, USA.
| |
Collapse
|
29
|
Ghaste M, Mistrik R, Shulaev V. Applications of Fourier Transform Ion Cyclotron Resonance (FT-ICR) and Orbitrap Based High Resolution Mass Spectrometry in Metabolomics and Lipidomics. Int J Mol Sci 2016; 17:ijms17060816. [PMID: 27231903 PMCID: PMC4926350 DOI: 10.3390/ijms17060816] [Citation(s) in RCA: 92] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2016] [Revised: 05/14/2016] [Accepted: 05/17/2016] [Indexed: 02/02/2023] Open
Abstract
Metabolomics, along with other "omics" approaches, is rapidly becoming one of the major approaches aimed at understanding the organization and dynamics of metabolic networks. Mass spectrometry is often a technique of choice for metabolomics studies due to its high sensitivity, reproducibility and wide dynamic range. High resolution mass spectrometry (HRMS) is a widely practiced technique in analytical and bioanalytical sciences. It offers exceptionally high resolution and the highest degree of structural confirmation. Many metabolomics studies have been conducted using HRMS over the past decade. In this review, we will explore the latest developments in Fourier transform mass spectrometry (FTMS) and Orbitrap based metabolomics technology, its advantages and drawbacks for using in metabolomics and lipidomics studies, and development of novel approaches for processing HRMS data.
Collapse
Affiliation(s)
- Manoj Ghaste
- Department of Biological Sciences, College of Arts and Sciences, University of North Texas, Denton, TX 76203, USA.
| | | | - Vladimir Shulaev
- Department of Biological Sciences, College of Arts and Sciences, University of North Texas, Denton, TX 76203, USA.
| |
Collapse
|
30
|
Park SG, Anderson GA, Navare AT, Bruce JE. Parallel Spectral Acquisition with an Ion Cyclotron Resonance Cell Array. Anal Chem 2016; 88:1162-8. [PMID: 26669509 PMCID: PMC4848028 DOI: 10.1021/acs.analchem.5b02987] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Mass measurement accuracy is a critical analytical figure-of-merit in most areas of mass spectrometry application. However, the time required for acquisition of high-resolution, high mass accuracy data limits many applications and is an aspect under continual pressure for development. Current efforts target implementation of higher electrostatic and magnetic fields because ion oscillatory frequencies increase linearly with field strength. As such, the time required for spectral acquisition of a given resolving power and mass accuracy decreases linearly with increasing fields. Mass spectrometer developments to include multiple high-resolution detectors that can be operated in parallel could further decrease the acquisition time by a factor of n, the number of detectors. Efforts described here resulted in development of an instrument with a set of Fourier transform ion cyclotron resonance (ICR) cells as detectors that constitute the first MS array capable of parallel high-resolution spectral acquisition. ICR cell array systems consisting of three or five cells were constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. Independent ion populations were injected and trapped within each cell in the array. Upon filling the array, all ions in all cells were simultaneously excited and ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition, parallel mass spectrometry (MS) and MS/MS measurements, and parallel high-resolution acquisition with the MS array system.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington , Seattle, Washington 98109, United States
| | - Gordon A Anderson
- GAA Custom Engineering, LLC, Benton City, Washington 99320, United States
| | - Arti T Navare
- Department of Genome Sciences, University of Washington , Seattle, Washington 98109, United States
| | - James E Bruce
- Department of Genome Sciences, University of Washington , Seattle, Washington 98109, United States
| |
Collapse
|
31
|
Nicolardi S, Bogdanov B, Deelder AM, Palmblad M, van der Burgt YEM. Developments in FTICR-MS and Its Potential for Body Fluid Signatures. Int J Mol Sci 2015; 16:27133-44. [PMID: 26580595 PMCID: PMC4661870 DOI: 10.3390/ijms161126012] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Revised: 11/03/2015] [Accepted: 11/05/2015] [Indexed: 01/01/2023] Open
Abstract
Fourier transform mass spectrometry (FTMS) is the method of choice for measurements that require ultra-high resolution. The establishment of Fourier transform ion cyclotron resonance (FTICR) MS, the availability of biomolecular ionization techniques and the introduction of the Orbitrap™ mass spectrometer have widened the number of FTMS-applications enormously. One recent example involves clinical proteomics using FTICR-MS to discover and validate protein biomarker signatures in body fluids such as serum or plasma. These biological samples are highly complex in terms of the type and number of components, their concentration range, and the structural identity of each species, and thus require extensive sample cleanup and chromatographic separation procedures. Clearly, such an elaborate and multi-step sample preparation process hampers high-throughput analysis of large clinical cohorts. A final MS read-out at ultra-high resolution enables the analysis of a more complex sample and can thus simplify upfront fractionations. To this end, FTICR-MS offers superior ultra-high resolving power with accurate and precise mass-to-charge ratio (m/z) measurement of a high number of peptides and small proteins (up to 20 kDa) at isotopic resolution over a wide mass range, and furthermore includes a wide variety of fragmentation strategies to characterize protein sequence and structure, including post-translational modifications (PTMs). In our laboratory, we have successfully applied FTICR “next-generation” peptide profiles with the purpose of cancer disease classifications. Here we will review a number of developments and innovations in FTICR-MS that have resulted in robust and routine procedures aiming for ultra-high resolution signatures of clinical samples, exemplified with state-of-the-art examples for serum and saliva.
Collapse
Affiliation(s)
- Simone Nicolardi
- Center for Proteomics and Metabolomics, Leiden University Medical Center (LUMC), PO Box 9600, 2300 RC Leiden, The Netherlands.
| | - Bogdan Bogdanov
- Perkin Elmer, San Jose Technology Center, San Jose, CA 95134, USA.
| | - André M Deelder
- Center for Proteomics and Metabolomics, Leiden University Medical Center (LUMC), PO Box 9600, 2300 RC Leiden, The Netherlands.
| | - Magnus Palmblad
- Center for Proteomics and Metabolomics, Leiden University Medical Center (LUMC), PO Box 9600, 2300 RC Leiden, The Netherlands.
| | - Yuri E M van der Burgt
- Center for Proteomics and Metabolomics, Leiden University Medical Center (LUMC), PO Box 9600, 2300 RC Leiden, The Netherlands.
| |
Collapse
|
32
|
Jertz R, Friedrich J, Kriete C, Nikolaev EN, Baykut G. Tracking the Magnetron Motion in FT-ICR Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:1349-1366. [PMID: 25971670 DOI: 10.1007/s13361-015-1148-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2014] [Revised: 03/19/2015] [Accepted: 03/20/2015] [Indexed: 06/04/2023]
Abstract
In Fourier transform ion cyclotron resonance spectrometry (FT-ICR MS) the ion magnetron motion is not usually directly measured, yet its contribution to the performance of the FT-ICR cell is important. Its presence is manifested primarily by the appearance of even-numbered harmonics in the spectra. In this work, the relationship between the ion magnetron motion in the ICR cell and the intensities of the second harmonic signal and its sideband peak in the FT-ICR spectrum is studied. Ion motion simulations show that during a cyclotron motion excitation of ions which are offset to the cell axis, a position-dependent radial drift of the cyclotron center takes place. This radial drift can be directed outwards if the ion is initially offset towards one of the detection electrodes, or it can be directed inwards if the ion is initially offset towards one of the excitation electrodes. Consequently, a magnetron orbit diameter can increase or decrease during a resonant cyclotron excitation. A method has been developed to study this behavior of the magnetron motion by acquiring a series of FT-ICR spectra using varied post-capture delay (PCD) time intervals. PCD is the delay time after the capture of the ions in the cell before the cyclotron excitation of the ion is started. Plotting the relative intensity of the second harmonic sideband peak versus the PCD in each mass spectrum leads to an oscillating "PCD curve". The position and height of minima and maxima of this curve can be used to interpret the size and the position of the magnetron orbit. Ion motion simulations show that an off-axis magnetron orbit generates even-numbered harmonic peaks with sidebands at a distance of one magnetron frequency and multiples of it. This magnetron offset is due to a radial offset of the electric field axis versus the geometric cell axis. In this work, we also show how this offset of the radial electric field center can be corrected by applying appropriate DC correction voltages to the mantle electrodes of the ICR cell while observing the signals of the second harmonic peak group. The field correction leads to a definite performance increase in terms of resolving power and mass accuracy, and the mass spectrum contains intensity-minimized even-numbered harmonics. This is very important in the case of high performance cells, particularly the dynamically harmonized cell, since the magnetron motion can severely impair the averaging effect for dynamic harmonization and can therefore reduce the resolving power.
Collapse
|
33
|
Nagornov KO, Kozhinov AN, Tsybin OY, Tsybin YO. Ion trap with narrow aperture detection electrodes for Fourier transform ion cyclotron resonance mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:741-751. [PMID: 25773900 DOI: 10.1007/s13361-015-1089-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2014] [Revised: 01/27/2015] [Accepted: 01/29/2015] [Indexed: 06/04/2023]
Abstract
The current paradigm in ion trap (cell) design for Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is the ion detection with wide aperture detection electrodes. Specifically, excitation and detection electrodes are typically 90° wide and positioned radially at a similar distance from the ICR cell axis. Here, we demonstrate that ion detection with narrow aperture detection electrodes (NADEL) positioned radially inward of the cell's axis is feasible and advantageous for FT-ICR MS. We describe design details and performance characteristics of a 10 T FT-ICR MS equipped with a NADEL ICR cell having a pair of narrow aperture (flat) detection electrodes and a pair of standard 90° excitation electrodes. Despite a smaller surface area of the detection electrodes, the sensitivity of the NADEL ICR cell is not reduced attributable to improved excite field distribution, reduced capacitance of the detection electrodes, and their closer positioning to the orbits of excited ions. The performance characteristics of the NADEL ICR cell are comparable with the state-of-the-art FT-ICR MS implementations for small molecule, peptide, protein, and petroleomics analyses. In addition, the NADEL ICR cell's design improves the flexibility of ICR cells and facilitates implementation of advanced capabilities (e.g., quadrupolar ion detection for improved mainstream applications). It also creates an intriguing opportunity for addressing the major bottleneck in FTMS-increasing its throughput via simultaneous acquisition of multiple transients or via generation of periodic non-sinusoidal transient signals.
Collapse
Affiliation(s)
- Konstantin O Nagornov
- Biomolecular Mass Spectrometry Laboratory, Ecole Polytechnique Fédérale de Lausanne, 1015, Lausanne, Switzerland
| | | | | | | |
Collapse
|
34
|
Guo D, Xin Y, Li D, Xu W. Collision cross section measurements for biomolecules within a high-resolution FT-ICR cell: theory. Phys Chem Chem Phys 2015; 17:9060-7. [DOI: 10.1039/c4cp06065b] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
An energetic hard-sphere collision model for modern high-resolution FT-ICR.
Collapse
Affiliation(s)
- Dan Guo
- School of Life Science
- Beijing Institute of Technology
- Beijing 100081
- China
| | - Yi Xin
- School of Life Science
- Beijing Institute of Technology
- Beijing 100081
- China
| | - Dayu Li
- College of Information Science and Engineering
- Northeastern University
- Shenyang 110819
- China
| | - Wei Xu
- School of Life Science
- Beijing Institute of Technology
- Beijing 100081
- China
| |
Collapse
|