1
|
Abstract
Membrane chromatography (MC) is an emerging bioseparation technology combining the principles of membrane filtration and chromatography. In this process, one type of molecule is adsorbed in the stationary phase, whereas the other type of molecule is passed through the membrane pores without affecting the adsorbed molecule. In subsequent the step, the adsorbed molecule is recovered by an elution buffer with a unique ionic strength and pH. Functionalized microfiltration membranes are usually used in radial flow, axial flow, and lateral flow membrane modules in MC systems. In the MC process, the transport of a solute to a stationary phase is mainly achieved through convection and minimum pore diffusion. Therefore, mass transfer resistance and pressure drop become insignificant. Other characteristics of MC systems are a minimum clogging tendency in the stationary phase, the capability of operating with a high mobile phase flow rate, and the disposable (short term) application of stationary phase. The development and application of MC systems for the fractionation of individual proteins from whey for investigation and industrial-scale production are promising. A significant income from individual whey proteins together with the marketing of dairy foods may provide a new commercial outlook in dairy industry. In this review, information about the development of a MC system and its applications for the fractionation of individual protein from whey are presented in comprehensive manner.
Collapse
|
2
|
Lynch KB, Ren J, Beckner MA, He C, Liu S. Monolith columns for liquid chromatographic separations of intact proteins: A review of recent advances and applications. Anal Chim Acta 2018; 1046:48-68. [PMID: 30482303 DOI: 10.1016/j.aca.2018.09.021] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Revised: 09/10/2018] [Accepted: 09/11/2018] [Indexed: 01/20/2023]
Abstract
In this article we survey 256 references (with an emphasis on the papers published in the past decade) on monolithic columns for intact protein separation. Protein enrichment and purification are included in the broadly defined separation. After a brief introduction, we describe the types of monolithic columns and modes of chromatographic separations employed for protein separations. While the majority of the work is still in the research and development phase, papers have been published toward utilizing monolithic columns for practical applications. We survey these papers as well in this review. Characteristics of selected methods along with their pros and cons will also be discussed.
Collapse
Affiliation(s)
- Kyle B Lynch
- Department of Chemistry and Biochemistry, University of Oklahoma, 101 Stephenson Parkway, Norman, OK, 73019, United States
| | - Jiangtao Ren
- Department of Chemistry and Biochemistry, University of Oklahoma, 101 Stephenson Parkway, Norman, OK, 73019, United States
| | - Matthew A Beckner
- Department of Chemistry and Biochemistry, University of Oklahoma, 101 Stephenson Parkway, Norman, OK, 73019, United States
| | - Chiyang He
- School of Chemistry and Chemical Engineering, Wuhan Textile University, 1 Textile Road, Wuhan, 430073, PR China
| | - Shaorong Liu
- Department of Chemistry and Biochemistry, University of Oklahoma, 101 Stephenson Parkway, Norman, OK, 73019, United States.
| |
Collapse
|
3
|
Prasanna RR, Kamalanathan AS, Vijayalakshmi MA. Development ofl-histidine immobilized CIM®monolithic disks for purification of immunoglobulin G. J Mol Recognit 2015; 28:129-41. [DOI: 10.1002/jmr.2372] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2013] [Revised: 01/29/2014] [Accepted: 03/16/2014] [Indexed: 11/10/2022]
Affiliation(s)
- Rajasekar R. Prasanna
- Centre for Bioseparation Technology; VIT University; Vellore 632014 Tamil Nadu India
| | | | | |
Collapse
|
4
|
Vlakh EG, Tennikova TB. Flow-through immobilized enzyme reactors based on monoliths: I. Preparation of heterogeneous biocatalysts. J Sep Sci 2013; 36:110-27. [DOI: 10.1002/jssc.201200594] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2012] [Revised: 08/13/2012] [Accepted: 08/13/2012] [Indexed: 11/11/2022]
Affiliation(s)
- Evgenia G. Vlakh
- Institute of Macromolecular Compounds; Russian Academy of Sciences; St. Petersburg Russia
- Faculty of Chemistry; Saint-Petersburg State University; St. Petersburg Russia
| | - Tatiana B. Tennikova
- Institute of Macromolecular Compounds; Russian Academy of Sciences; St. Petersburg Russia
- Faculty of Chemistry; Saint-Petersburg State University; St. Petersburg Russia
| |
Collapse
|
5
|
Gehrke CW, Hage DS. Chromatography-Advances and Applications in Environmental, Space, Biological, and Medical Sciences. CHROMATOGRAPHY 2010. [DOI: 10.1002/9780470555729.ch7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
6
|
Prasanna RR, Vijayalakshmi MA. Characterization of metal chelate methacrylate monolithic disk for purification of polyclonal and monoclonal immunoglobulin G. J Chromatogr A 2010; 1217:3660-7. [DOI: 10.1016/j.chroma.2010.03.058] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2009] [Revised: 03/13/2010] [Accepted: 03/30/2010] [Indexed: 11/29/2022]
|
7
|
Preparation of macroporous monoliths based on epoxy-bearing hydrophilic terpolymers and applied for affinity separations. Eur Polym J 2010. [DOI: 10.1016/j.eurpolymj.2010.01.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
8
|
Urbas L, Brne P, Gabor B, Barut M, Strlic M, Petric TC, Strancar A. Depletion of high-abundance proteins from human plasma using a combination of an affinity and pseudo-affinity column. J Chromatogr A 2008; 1216:2689-94. [PMID: 19010473 DOI: 10.1016/j.chroma.2008.10.104] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2008] [Revised: 10/24/2008] [Accepted: 10/29/2008] [Indexed: 10/21/2022]
Abstract
Human serum albumin (HSA) and immunoglobulin G (IgG) represent over 75% of all proteins present in human plasma. These high-abundance proteins prevent the detection of low-abundance proteins which are potential markers for various diseases. The depletion of HSA and IgG is therefore essential for further proteome analysis. In this paper we describe the optimization of conditions for selective depletion of HSA and IgG using affinity and pseudo-affinity chromatography. A BIA Separations CIM (convective interaction media) Protein G disk was applied for the removal of IgG and the Mimetic Blue SA A6XL stationary phase for the removal of HSA. The binding and the elution buffer for CIM Protein G disk were chosen on the basis of the peak shape. The dynamic binding capacity was determined. It was shown to be dependent on the buffer system used and independent of the flow rate and of the concentration of IgG. Beside the binding capacity for the IgG standard, the binding capacity was also determined for IgG in human plasma. The Mimetic Blue SA A6XL column was characterized using human plasma. The selectivity of the depletion was dependent on the amount of human plasma that was loaded on the column. After the conditions on both supports had been optimized, the Mimetic Blue SA A6XL stationary phase was combined with the CIM Protein G disk in order to simultaneously deplete samples of human plasma. A centrifuge spin column that enables the removal of IgG and HSA from 20 microL of human plasma was designed. The results of the depletion were examined using sodium dodecyl sulfate polyacrylamide gel electrophoresis and two-dimensional gel electrophoresis.
Collapse
Affiliation(s)
- Lidija Urbas
- BIA Separations d.o.o., Teslova 30, SI-1000 Ljubljana, Slovenia.
| | | | | | | | | | | | | |
Collapse
|
9
|
Abstract
The combined use of monolithic supports with selective affinity ligands as stationary phases has recently given rise to a new method known as affinity monolith chromatography (AMC). This review will discuss the basic principles behind AMC and examine the types of supports and ligands that have been employed in this method. Approaches for placing affinity ligands in monoliths will be considered, including methods based on covalent immobilization, biospecific adsorption, entrapment, and the formation of coordination complexes. Several reported applications will then be presented, such as the use of AMC for bioaffinity chromatography, immunoaffinity chromatography, immobilized metal-ion affinity chromatography, dye-ligand affinity chromatography, and biomimetic chromatography. Other applications that will be discussed are chiral separations and studies of biological interactions based on AMC.
Collapse
Affiliation(s)
- Rangan Mallik
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | | |
Collapse
|
10
|
Petric TC, Brne P, Gabor B, Govednik L, Barut M, Strancar A, Kralj LZ. Anion-exchange chromatography using short monolithic columns as a complementary technique for human serum albumin depletion prior to human plasma proteome analysis. J Pharm Biomed Anal 2006; 43:243-9. [PMID: 16875792 DOI: 10.1016/j.jpba.2006.06.019] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2005] [Revised: 06/12/2006] [Accepted: 06/12/2006] [Indexed: 11/26/2022]
Abstract
In order to enable the detection of low abundance proteins from human plasma, it is necessary to remove high abundance proteins. Among them, human serum albumin and immunoglobulin G represent more than 75% of all such proteins. In this paper, the characterization of short monolithic columns was performed followed by the optimization of a multidimensional approach, known as conjoint liquid chromatography, to deplete human serum albumin and immunoglobulin G from a human plasma sample. Two different chromatographic modes were used: ion-exchange chromatography and affinity chromatography. A monolithic stationary phase (convective interaction media disk) bearing strong anion-exchange groups and another immobilized with protein G were placed in series into one housing. The optimal binding conditions were found that removed a majority of human serum albumin and immunoglobulin G from the human plasma sample. This method was compared to the depletion using a combination of pseudo-affinity and affinity columns. The results of the human serum albumin and immunoglobulin G depletion were confirmed by 2D electrophoresis. It has been shown that anion-exchange and affinity chromatography using convective interaction media monolithic columns can represent an efficient complementary technique for human serum albumin and immunoglobulin G removal from human plasma.
Collapse
|
11
|
Svec F. Less common applications of monoliths: I. Microscale protein mapping with proteolytic enzymes immobilized on monolithic supports. Electrophoresis 2006; 27:947-61. [PMID: 16470758 DOI: 10.1002/elps.200500661] [Citation(s) in RCA: 128] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This review summarizes the recent contributions to the rapidly growing area of immobilized enzymes employing both silica and synthetic polymer-based monoliths as supports. Focus is mainly on immobilized proteolytic enzyme reactors designed for studies in proteomics. Porous monoliths emerged first as a new class of stationary phases for HPLC in the early 1990s. Soon thereafter, they were also used as supports for immobilization of proteins and preparation of both stationary phases for bioaffinity chromatography and enzymatic reactors. Organic polymer-based monoliths are typically prepared using a simple molding process carried out within the confines of a "mold" such as chromatographic column or capillary. Polymerization of a mixture comprising monomers, initiator, and porogenic solvent affords macroporous materials. In contrast, silica-based monoliths are first formed as a rigid rod from tetraalkoxysilane in the presence of PEG and subsequently encased with a plastic tube. Both types of monolith feature large through-pores that enable a rapid flow-through. Since all the solutions must flow through the monolith, the convection considerably accelerates mass transfer within the monolith. As a result, reactors including enzyme immobilized on monolithic support exhibit much higher activity compared to the reactions in solution.
Collapse
Affiliation(s)
- Frantisek Svec
- Department of Chemistry, University of California, Berkeley, CA, USA.
| |
Collapse
|
12
|
Theoretical Aspects of Separation Using Short Monolithic Beds. ACTA ACUST UNITED AC 2003. [DOI: 10.1016/s0301-4770(03)80032-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
13
|
Gustavsson PE, Son PO. Monolithic Polysaccharide Materials. JOURNAL OF CHROMATOGRAPHY LIBRARY 2003. [DOI: 10.1016/s0301-4770(03)80022-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
14
|
Branovic K, Lattner G, Barut M, Strancar A, Josic D, Buchacher A. Very fast analysis of impurities in immunoglobulin concentrates using conjoint liquid chromatography on short monolithic disks. J Immunol Methods 2002; 271:47-58. [PMID: 12445728 DOI: 10.1016/s0022-1759(02)00339-3] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Transferrin and albumin are often present in immunoglobulin G (IgG) concentrates and are considered as impurities. Therefore, it is important to determine their concentration in order to obtain a well-characterized biological product. Here, we describe their determination based on conjoint liquid chromatography (CLC). The established method combines two different chromatographic modes in one step: affinity and ion-exchange chromatography (IEC) combined in one column. Therefore, two CIM Protein G and one CIM quaternary amine (QA) monolithic disks were placed in series in one housing forming a CLC monolithic column. Binding conditions were optimized in a way that immunoglobulins were captured on the CIM Protein G disks, while transferrin and albumin were bound on the CIM QA disks. Subsequently, transferrin and albumin were eluted separately by a stepwise gradient with sodium chloride, whereas immunoglobulins were released from the Protein G ligands by applying low pH. A complete separation of all three proteins was achieved in less than 5 min. The method permits the quantification of albumin and transferrin in IgG concentrates and has been successfully validated.
Collapse
Affiliation(s)
- K Branovic
- Institute of Immunology, Inc., Zagreb, Croatia
| | | | | | | | | | | |
Collapse
|
15
|
Luo Q, Zou H, Zhang Q, Xiao X, Ni J. High-performance affinity chromatography with immobilization of protein A and L-histidine on molded monolith. Biotechnol Bioeng 2002; 80:481-9. [PMID: 12355458 DOI: 10.1002/bit.10391] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Reactive monoliths of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) have been prepared by "in-situ" copolymerization of the monomers in the presence of porogenic diluents. Protein A and L-histidine were immobilized on the monoliths directly or through a spacer arm, respectively. The properties of these two kinds of affinity columns were characterized, and the results showed that the columns with coupling of ligands by a spacer arm have some extent of non-specific adsorption for bovine serum albumin. The affinity column based on the monolithic polymer support provided us with good hydrodynamic characteristic, low flow resistance, and easy preparation. These two affinity columns were used for the purification of immunoglobulin G from human serum. The purity of the purified IgG was detected by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The stability of the protein A affinity column was investigated, and its performance remained invariable after half a year. The effects of the nature and the pH of the buffer system on the adsorption capacity of human IgG on histidyl affinity column were also investigated. The protein A affinity column is favorable for rapid analysis of human IgG samples. In contrast, the advantages of mild elution conditions, high stability, as well as low cost provide the histidyl column further potential possibility for fast removal of IgG from human plasma in clinical applications.
Collapse
Affiliation(s)
- Quanzhou Luo
- National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, China
| | | | | | | | | |
Collapse
|
16
|
Luo Q, Mao X, Kong L, Huang X, Zou H. High-performance affinity chromatography for characterization of human immunoglobulin G digestion with papain. J Chromatogr B Analyt Technol Biomed Life Sci 2002; 776:139-47. [PMID: 12137995 DOI: 10.1016/s1570-0232(02)00105-8] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Reactive continuous rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) were prepared within the confines of a stainless steel column. Then papain was immobilized on these monoliths either directly or linked by a spacer arm. In a further step, a protein A affinity column was used for the characterization of the digestion products of human immunoglobulin G (IgG) by papain. The results showed that papain immobilized on the monolithic rod through a spacer arm exhibits higher activity for the digestion of human IgG than that without a spacer arm. The apparent Michaelis-Menten kinetic constants of free and immobilized papain, K(m) and V(max), were determined. The digestion conditions of human IgG with free and immobilized papain were optimized. Comparison of the thermal stability of free and immobilized papain showed that the immobilized papain exhibited higher thermal stability than the free enzyme. The half-time of immobilized papain reaches about a week under optimum pH and temperature conditions.
Collapse
Affiliation(s)
- Quanzhou Luo
- National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 161 Zhongshan Road, Dalian 116011, China
| | | | | | | | | |
Collapse
|
17
|
Pan Z, Zou H, Mo W, Huang X, Wu R. Protein A immobilized monolithic capillary column for affinity chromatography. Anal Chim Acta 2002. [DOI: 10.1016/s0003-2670(02)00511-1] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
18
|
Josić D, Buchacher A. Application of monoliths as supports for affinity chromatography and fast enzymatic conversion. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS 2001; 49:153-74. [PMID: 11694278 DOI: 10.1016/s0165-022x(01)00195-6] [Citation(s) in RCA: 98] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Monoliths are useful chromatographic supports, as their structure allows improved mass transport. This results in fast separation. Once the ligand of interest has been immobilized, chromatographic separation can also be accomplished in affinity mode. Ligands with low molecular mass have been shown to be the easiest to immobilize. Nowadays, ligands with low molecular mass are often designed by combinatorial chemical techniques. In addition, many applications have been described where ligands with high molecular mass, such as Proteins A and G, antibodies, lectins and receptors are used. The immobilization of an enzyme on the monolithic support creates a flow-through reactor. Small proteins, such as carbonic anhydrase, can be directly immobilized on the support. However, in the case of large molecules, the active center of the enzyme is no longer accessible at all or only to a limited degree. An improvement can be achieved by introducing a spacer, which allows maximum enzymatic conversion. Fast conversion of substrates with high molecular mass has been investigated with immobilized trypsin. It was shown that in case of high-molecular-mass substrates, the conversion rate depends very much on the flow-rate. Most applications described have been performed on an analytical or semi-preparative scale. However, the technical problems of up-scaling are close to being definitely solved, enabling enzymatic conversion on a preparative scale in the future.
Collapse
Affiliation(s)
- D Josić
- Research and Development, Octapharma Pharmazeutika Produktions Ges.m.b.H., Oberlaaerstrasse 235, A-1100 Vienna, Austria.
| | | |
Collapse
|
19
|
Zou H, Luo Q, Zhou D. Affinity membrane chromatography for the analysis and purification of proteins. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS 2001; 49:199-240. [PMID: 11694281 DOI: 10.1016/s0165-022x(01)00200-7] [Citation(s) in RCA: 187] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Affinity chromatography is unique among separation methods as it is the only technique that permits the purification of proteins based on biological functions rather than individual physical or chemical properties. The high specificity of affinity chromatography is due to the strong interaction between the ligand and the proteins of interest. Membrane separation allows the processing of a large amount of sample in a relatively short time owing to its structure, which provides a system with rapid reaction kinetics. The integration of membrane and affinity chromatography provides a number of advantages over traditional affinity chromatography with porous-bead packed columns, especially with regard to time and recovery of activity. This review gives detailed descriptions of materials used as membrane substrates, preparation of basic membranes, coupling of affinity ligands to membrane supports, and categories of affinity membrane cartridges. It also summarizes the applications of cellulose/glycidyl methacrylate composite membranes for proteins separation developed in our laboratory.
Collapse
Affiliation(s)
- H Zou
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116011, China.
| | | | | |
Collapse
|
20
|
Luo Q, Zou H, Xiao X, Guo Z, Kong L, Mao X. Chromatographic separation of proteins on metal immobilized iminodiacetic acid-bound molded monolithic rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate). J Chromatogr A 2001; 926:255-64. [PMID: 11556331 DOI: 10.1016/s0021-9673(01)01055-x] [Citation(s) in RCA: 111] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Continuous rod of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) was prepared by a free radical polymerization within the confines of a stainless-steel column. The epoxide groups of the rod were modified by a reaction with iminodiacetic acid (IDA) that affords the active site to form metal IDA chelates used for immobilized metal affinity chromatography (IMAC). The efficiency of coupling of IDA to the epoxide-contained matrix was studied as a function of reaction time and temperature. High-performance separation of proteins, based on immobilized different metals on the column, were described. The influence of pH on the adsorption capacity of bovine serum albumin on the Cu2+-IDA continuous rod column was investigated in the range from 5.0 to 9.0. Purification of lysozyme from egg white and human serum albumin (HSA) on the commercially available HSA solution were performed on the naked IDA and Cu2+-IDA continuous rod columns, respectively; and the purity of the obtained fractions was detected by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry.
Collapse
Affiliation(s)
- Q Luo
- National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian.
| | | | | | | | | | | |
Collapse
|
21
|
Clarke W, Hage DS. Development of sandwich HPLC microcolumns for analyte adsorption on the millisecond time scale. Anal Chem 2001; 73:1366-73. [PMID: 11305676 DOI: 10.1021/ac000870z] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A new class of columns is reported that uses only microgram quantities of active support and that provides for the retention of biological compounds and other analytes on the millisecond time scale. This was accomplished by packing standard HPLC supports into layers as small as 60 microm in length and using only 90 microg of support material. This provided columns with effective residence times in the millisecond time range when routine HPLC flow rates and pressures were used. The retention of analytes by such columns was examined under both adsorption- and diffusion-limited conditions. The RPLC adsorption of hemoglobin (a system with diffusion-limited retention) was found to give 95% binding in as little as 4 ms. The adsorption of fluorescein by an anti-fluorescein antibody column (an adsorption-limited system) gave 95% retention in 100-120 ms. One application examined for these columns was their use in a chromatographic-based competitive binding immunoassay. This used bovine serum albumin (BSA) as the model analyte, and fluorescein-labeled BSA was used for detection. The resulting approach had a contact time of 180 ms between the sample and an anti-BSA immunoaffinity microcolumn and provided a signal within 5-25 s after sample injection. The columns developed in this work should also be useful in other situations that involve a small amount of a stationary phase or that require short column residence times.
Collapse
Affiliation(s)
- W Clarke
- Department of Chemistry, University of Nebraska, Lincoln 68588-0304, USA
| | | |
Collapse
|
22
|
Zhou D, Zou H, Wang H, Ni J, Zhang Q, Zhang Y. Alkaline treatment of the cellulose fiber affecting membrane column behaviour for high-performance immunoaffinity chromatography. Biomed Chromatogr 2000; 14:511-5. [PMID: 11113934 DOI: 10.1002/1099-0801(200012)14:8<511::aid-bmc16>3.0.co;2-b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The original cellulose fibers and those treated by alkaline solution were both used to prepare the acrylic membranes. The two kinds of membranes were packed into the columns for high-performance immunoaffinity chromatography by the immobilization of protein A on them. It was observed that the alkaline treatment of the cellulose fiber decreased the pressure resistance of the membrane to the mobile phases and greatly increased the accessible volume to the proteins, but affected the adsorption capacity of human IgG on the protein A membrane columns less. There is little difference between those two kinds of membranes on the adsorption capacities of HIgG, which means that the alkaline treatment of the cellulose fiber only significantly changes the void volume inter-membrane, and the porosity and surface area of membrane less. Alkaline treatment of the cellulose fiber reduced the membrane-column efficiency significantly. Some typical examples for the immunoaffinity analysis of IgG from human and dog plasma on the protein A membrane columns are illustrated.
Collapse
Affiliation(s)
- D Zhou
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, The Chinese Academy of Sciences, Dalian 116011, People's Republic of China
| | | | | | | | | | | |
Collapse
|
23
|
Jiang H, Zou H, Wang H, Ni J, Zhang Q, Zhang Y. On-line characterization of the activity and reaction kinetics of immobilized enzyme by high-performance frontal analysis. J Chromatogr A 2000; 903:77-84. [PMID: 11153957 DOI: 10.1016/s0021-9673(00)00846-3] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A microreactor by immobilized trypsin on the activated glycidyl methacrylate-modified cellulose membrane packed column was constructed. Immobilized trypsin mirrored the properties of the free enzyme and showed high stability. A novel method to characterize the activity and reaction kinetics of the immobilized enzyme has been developed based on the frontal analysis of enzymatic reaction products, which was performed by the on-line monitoring of the absorption at 410 nm of p-nitroaniline from the hydrolysis of N-alpha-benzoyl-DL-arginine-p-nitroanilide (BAPNA). The hydrolytic activity of the immobilized enzyme was 55.6% of free trypsin. The apparent Michaelis-Menten kinetics constant (Km) and Vmax values measured by the frontal analysis method were, respectively, 0.12 mM and 0.079 mM min(-1) mg enzyme(-1). The former is very close to that observed by the static and off-line detection methods, but the latter is about 15% higher than that of the static method. Inhibition of the immobilized trypsin by addition of benzamidine into substrate solution has been studied by the frontal analysis method. The apparent Michaelis-Menten constant of BAPNA (Km), the inhibition constant of benzamidine (Ki) and Vmax were determined. It was indicated that the interaction of BAPNA and benzamidine with trypsin is competitive, the Km value was affected but the Vmax was unaffected by the benzamidine concentration.
Collapse
Affiliation(s)
- H Jiang
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences
| | | | | | | | | | | |
Collapse
|
24
|
Jiang H, Zou H, Wang H, Zhang Q, Ni J, Zhang Q, Guo Z, Chen X. Combination of MALDI-TOF mass spectrometry with immobilized enzyme microreactor for peptide mapping. ACTA ACUST UNITED AC 2000. [DOI: 10.1007/bf02969510] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
25
|
García MC, Marina ML, Torre M. Perfusion chromatography: an emergent technique for the analysis of food proteins. J Chromatogr A 2000; 880:169-87. [PMID: 10890519 DOI: 10.1016/s0021-9673(00)00354-x] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Perfusion chromatography is a technique arised to overcome the problem associated with mass transfer in the separation of large molecules such as proteins by high-performance liquid chromatography (HPLC). Perfusion media are constituted by two set of pores: throughpores (6000-8000 A) and diffusive pores (800-1500 A) which enable better access of macromolecules to the inner of the particle by the combination of convective and diffusive flow. As a consequence, times required for a chromatographic separation are reduced. Perfusion media are available in different chromatographic modes: reversed-phase, ion-exchange, hydrophobic interaction, and affinity. From the theoretical models developed to explain the dynamic of retention of solutes in perfusive supports, it was derived that efficiency of a separation was independent of the flow-rate and only depended slightly on the particle diameter. Furthermore, loading capacity was also independent of the superficial velocity. All these advantages have promoted the use of this chromatographic technique for the separation of biomolecules both in analytical and preparative chromatography. Characteristics of perfusion chromatography make this technique very interesting for the analysis of food proteins. Perfusion chromatography enables the assessment of protein composition of a foodstuff at sufficient speed and low cost to be suitable in routine analysis.
Collapse
Affiliation(s)
- M C García
- Departamento de Química Analítica, Facultad de Ciencias, Universidad de Alcalá, Madrid, Spain
| | | | | |
Collapse
|
26
|
Zhou D, Zou H, Ni J, Wang H, Yang L, Zhang Y. Membrane affinity chromatography for analysis and purification of biopolymers. Chromatographia 1999. [DOI: 10.1007/bf02493613] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|