Foest D, Knodel A, Ahrends R, Coman C, Franzke J, Brandt S. Flexible Microtube Plasma for the Consecutive-Ionization of Cholesterol in Nano-Electrospray Mass Spectrometry. Anal Chem 2023. [PMID: 37220280 DOI: 10.1021/acs.analchem.2c04052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Electrospray ionization mass spectrometry (ESI-MS) is an established method for the identification of biomarkers. By nano-ESI (nESI), the polar molecular fraction of complex biological samples can be successfully ionized. In contrast, the less-polar free cholesterol, which serves as an important biomarker for several human diseases, is barely accessible by nESI. Although, complex scan functions of modern high-resolution MS devices are able to increase the signal-to-noise ratio, they are limited by the ionization efficiency of the nESI. One possible method to increase the ionization efficiency is the derivatization with acetyl chloride, however interferences with cholesteryl esters must be considered, so chromatographic separation or complex scan functions may be required. A novel approach to increase the yield of cholesterol ions of the nESI could be the application of a second consecutive-ionization process. This publication presents the flexible microtube plasma (FμTP) as a consecutive-ionization source, which allows the determination of cholesterol in nESI-MS analysis. Focusing on the analytical performance, the nESI-FμTP approach increases the cholesterol signal yield in a complex liver extract by a factor of 49. The repeatability and long-term stability could be successfully evaluated. A linear dynamic range of 1.7 orders of magnitude, a minimum detectability of 5.46 mg/L, and a high accuracy (deviation, -8.1%) demonstrates the nESI-FμTP-MS as an excellent approach for a derivatization-free determination of cholesterol.
Collapse
Affiliation(s)
- Daniel Foest
- Miniaturisation, Leibniz-Institut für Analytische Wissenschaften─ISAS─e.V., Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Alexander Knodel
- Miniaturisation, Leibniz-Institut für Analytische Wissenschaften─ISAS─e.V., Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Robert Ahrends
- Department of Analytical Chemistry, University of Vienna, Währingstr. 38, A-1090 Vienna, Austria
| | - Cristina Coman
- Department of Analytical Chemistry, University of Vienna, Währingstr. 38, A-1090 Vienna, Austria
| | - Joachim Franzke
- Miniaturisation, Leibniz-Institut für Analytische Wissenschaften─ISAS─e.V., Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Sebastian Brandt
- Miniaturisation, Leibniz-Institut für Analytische Wissenschaften─ISAS─e.V., Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| |
Collapse
|
2
|
Yue H, He F, Zhao Z, Duan Y. Plasma-based ambient mass spectrometry: Recent progress and applications. MASS SPECTROMETRY REVIEWS 2023; 42:95-130. [PMID: 34128567 DOI: 10.1002/mas.21712] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 05/28/2020] [Accepted: 06/02/2020] [Indexed: 06/12/2023]
Abstract
Ambient mass spectrometry (AMS) has grown as a group of advanced analytical techniques that allow for the direct sampling and ionization of the analytes in different statuses from their native environment without or with minimum sample pretreatments. As a significant category of AMS, plasma-based AMS has gained a lot of attention due to its features that allow rapid, real-time, high-throughput, in vivo, and in situ analysis in various fields, including bioanalysis, pharmaceuticals, forensics, food safety, and mass spectrometry imaging. Tens of new methods have been developed since the introduction of the first plasma-based AMS technique direct analysis in real-time. This review first provides a comprehensive overview of the established plasma-based AMS techniques from their ion source configurations, mechanisms, and developments. Then, the progress of the representative applications in various scientific fields in the past 4 years (January 2017 to January 2021) has been summarized. Finally, we discuss the current challenges and propose the future directions of plasma-based AMS from our perspective.
Collapse
Affiliation(s)
- Hanlu Yue
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Feiyao He
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Zhongjun Zhao
- School of Chemical Engineering, Sichuan University, Chengdu, China
| | - Yixiang Duan
- College of Life Sciences, Sichuan University, Chengdu, China
- School of Manufacturing Science and Engineering, Sichuan University, Chengdu, China
| |
Collapse
|
3
|
Ayala-Cabrera JF, Turkowski J, Uteschil F, Schmitz OJ. Development of a Tube Plasma Ion Source for Gas Chromatography-Mass Spectrometry Analysis and Comparison with Other Atmospheric Pressure Ionization Techniques. Anal Chem 2022; 94:9595-9602. [PMID: 35758294 DOI: 10.1021/acs.analchem.2c00582] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A tube plasma ionization (TPI) open-air source for gas chromatography-mass spectrometry (GC-MS) was developed. This source is based on an inverse low temperature plasma configuration where the pin inner electrode is applying the high voltage and the grounded electrode is the housing itself. The ionization possibilities were tested by using an EPA mix of priority contaminants, showing that 68% of the analytes could undergo both proton-transfer and charge-exchange reactions. The potential of using different discharge gases (He and Ar) to ionize the analytes and auxiliary gases (He, N2, O2, and synthetic air) to transport the ions toward the MS was carefully investigated. Additionally, the addition of water was also tested to show the different ionization trends in the TPI source. Finally, the ionization by TPI under both dry and wet conditions was compared with other gas-phase atmospheric pressure ionization sources showing TPI could ionize a wider range of compounds (97%) than atmospheric pressure chemical ionization (APCI, 95%) and atmospheric pressure photoionization (APPI, 87%). Besides, the detection capability of TPI was better than APCI and APPI, achieving instrumental limits of detection down to 3 fg on column, which demonstrates the great potential of this ionization source for GC-MS determinations.
Collapse
Affiliation(s)
- Juan F Ayala-Cabrera
- Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany.,Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany
| | - Jasmin Turkowski
- Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany.,Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany
| | - Florian Uteschil
- Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany.,Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany
| | - Oliver J Schmitz
- Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany.,Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany
| |
Collapse
|
4
|
Ionization of semi-fluorinated n-alkanes in controlled atmosphere using flexible micro-tube plasma (FμTP) ionization source with square- and sine-wave voltage. Talanta 2022; 249:123662. [PMID: 35691129 DOI: 10.1016/j.talanta.2022.123662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 05/10/2022] [Accepted: 06/04/2022] [Indexed: 11/21/2022]
Abstract
Non-thermal plasma-based ionization sources have been widely used and shown excellent soft ionization performance in mass spectrometry. Despite their extensive application, the ionization mechanisms of these sources are of great interest for further exploring their full potential. A controlled atmosphere can provide a clean and controllable ionization environment and is beneficial for studying the ionization mechanism. The plasma source itself also has a significant impact on the ionization mechanism of the analyte, and the voltage waveform is one of the key parameters for controlling the plasma source. In this paper, a miniature flexible micro-tube plasma (FμTP) ionization source was sustained using both square and sine-wave voltage. The ionization processes of typical semi-fluorinated n-alkanes (SFAs) were investigated in the controlled atmosphere filled with 80% N2 and 20% O2. The main mass peaks using both square and sine-wave voltages are found to be [M-mH]+ and [M-mH+nO]+ (m = 1, 3; n = 0, 1, 2). However, for the square-wave voltage, the [M-H+O]+ species are the most abundant while [M-H]+ species are dominant for the sine-wave voltage, showing that the plasma generated with sine-wave voltage is somewhat "softer" than the one with square-wave voltage for SFAs. With the assistance of optical spectroscopy, the plasma developments in one discharge cycle for both voltage waveforms were obtained. Only one discharge can be found in each half cycle for square-wave voltage while several for the sine-wave voltage. These would be responsible for the different ionization behaviors in these two cases. This work provides more insight into the ionization mechanism of SFAs and more understanding of plasma-based soft ionization. In addition, the analytical performance was evaluated to be comparable when using these two voltage generators with a big difference in cost, which will benefit the instrumental development.
Collapse
|
5
|
Foest D, Knodel A, Brandt S, Franzke J. Coupling paper spray ionization with the flexible microtube plasma for the determination of low polar biomarkers in mass spectrometry. Anal Chim Acta 2022; 1201:339619. [DOI: 10.1016/j.aca.2022.339619] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 01/21/2022] [Accepted: 02/14/2022] [Indexed: 11/15/2022]
|
6
|
Knodel A, Marggraf U, Hoffmann-Posorske E, Burhenn S, Brandt S, Ahlmann N, Foest D, Lorenz K, Franzke J. Pulsed Blue Laser Diode Thermal Desorption Microplasma Imaging Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:45-53. [PMID: 34856796 DOI: 10.1021/jasms.1c00221] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
An ambient air laser desorption, plasma ionization imaging method is developed and presented using a microsecond pulsed laser diode for desorption and a flexible microtube plasma for ionization of the neutral desorbate. Inherent parameters such as the laser repetition rate and pulse width are optimized to the imaging application. For the desorption substrate, copper spots on a copper-glass sandwich structure are used. This novel design enables imaging without ablating the metal into the mass spectrometer. On this substrate, fixed calibration markers are used to decrease the positioning error in the imaging process, featuring a 3D offset correction within the experiment. The image is both screened spot-by-spot and per line scanning at a constant speed, which allows direct comparison. In spot-by-spot scanning, a novel algorithm is presented to unfold and to reconstruct the imaging data. This approach significantly decreases the time required for the imaging process, which allows imaging even at decreased sampling rates and thus higher mass resolution. After the experiment, the raw data is automatically converted and interpreted by a second algorithm, which allows direct visualization of the image from the data, even on low-intensity signals. Mouse liver microtome cuts have been screened for dehydrated cholesterol, proving good agreement of the unfolded data with the morphology of the tissue. The method optically resolves 30 μm, with 30 μm diameter copper spots and a 10 μm gap. No conventional chemical matrices or vacuum conditions are required.
Collapse
Affiliation(s)
- Alexander Knodel
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Ulrich Marggraf
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Edeltraut Hoffmann-Posorske
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Sebastian Burhenn
- Experimental Physics II, Faculty of Physics and Astronomy, Ruhr-University Bochum, 44801 Bochum, Germany
| | - Sebastian Brandt
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Norman Ahlmann
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Daniel Foest
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Kristina Lorenz
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
- Institute of Pharmacology and Toxicology, University of Würzburg, 97078 Würzburg, Germany
| | - Joachim Franzke
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| |
Collapse
|
7
|
Lu Q, Xu Z, You X, Ma S, Zenobi R. Atmospheric Pressure Mass Spectrometry Imaging Using Laser Ablation, Followed by Dielectric Barrier Discharge Ionization. Anal Chem 2021; 93:6232-6238. [PMID: 33826303 DOI: 10.1021/acs.analchem.1c00549] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Mass spectrometry imaging (MSI) has become a powerful tool in diverse fields, for example, life science, biomaterials, and catalysis, for its ability of in situ and real-time visualization of the location of chemical compounds in samples. Although laser ablation (LA) achieves high spatial resolution in MSI, the ion yield can be very low. We therefore combined an LA system with an ambient ion source for post-ionization and an atmospheric pressure (AP) inlet mass spectrometer to construct a novel AP-MSI platform. A dielectric barrier discharge ionization (DBDI) source is operated in the "active sampling capillary" configuration, can be coupled to any mass spectrometer with an AP interface, and possesses high ion transmission efficiency. This study presents some application examples based on LA-DBDI, a low-cost and flexible strategy for AP-MSI, which does not require any sample pretreatment, and we show MS imaging of endogenous species in a traditional Chinese herbal medicine and of a drug molecule in zebra fish tissue, with a lateral resolution of ≈20 μm.
Collapse
Affiliation(s)
- Qiao Lu
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Zhouyi Xu
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Xue You
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Siyuan Ma
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Renato Zenobi
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.,Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093 Zurich , Switzerland
| |
Collapse
|