1
|
Horstmann M, Quarles CD, Happel S, Sperling M, Faust A, Rahbar K, Clases D, Karst U. Quantification of [ 99Tc]TcO 4- in urine by means of anion-exchange chromatography-aerosol desolvation nebulization-inductively coupled plasma-mass spectrometry. Anal Bioanal Chem 2024; 416:2849-2858. [PMID: 38289357 PMCID: PMC11009747 DOI: 10.1007/s00216-024-05149-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 01/09/2024] [Accepted: 01/11/2024] [Indexed: 04/13/2024]
Abstract
To sensitively determine 99Tc, a new method for internal quantification of its most common and stable species, [99Tc]Tc O 4 - , was developed. Anion-exchange chromatography (IC) was coupled to inductively coupled plasma-mass spectrometry (ICP-MS) and equipped with an aerosol desolvation system to provide enhanced detection power. Due to a lack of commercial Tc standards, an isotope dilution-like approach using a Ru spike and called isobaric dilution analysis (IBDA) was used for internal quantification of 99Tc. This approach required knowledge of the sensitivities of 99Ru and 99Tc in ICP-MS. The latter was determined using an in-house prepared standard manufactured from decayed medical 99mTc-generator eluates. This standard was cleaned and preconcentrated using extraction chromatography with TEVA resin and quantified via total reflection X-ray fluorescence (TXRF) analysis. IC coupled to ICP-MS enabled to separate, detect and quantify [99Tc]Tc O 4 - as most stable Tc species in complex environments, which was demonstrated in a proof of concept. We quantified this species in untreated and undiluted raw urine collected from a patient, who previously underwent scintigraphy with a 99mTc-tracer, and determined a concentration of 19.6 ± 0.5 ng L-1. The developed method has a high utility to characterize a range of Tc-based radiopharmaceuticals, to determine concentrations, purity, and degradation products in complex samples without the need to assess activity parameters of 99(m)Tc.
Collapse
Affiliation(s)
- Maximilian Horstmann
- Institute of Inorganic and Analytical Chemistry, University of Münster, Münster, Germany
| | | | | | - Michael Sperling
- European Virtual Institute for Speciation Analysis (EVISA), Münster, Germany
| | - Andreas Faust
- European Institute for Molecular Imaging (EIMI), Münster, Germany
| | - Kambiz Rahbar
- Department of Nuclear Medicine, University Hospital Münster, Münster, Germany
- West German Cancer Center, Münster, Germany
| | - David Clases
- Institute of Chemistry, University of Graz, Graz, Austria.
| | - Uwe Karst
- Institute of Inorganic and Analytical Chemistry, University of Münster, Münster, Germany.
| |
Collapse
|
2
|
Marques SS, Ramos II, Silva C, Barreiros L, Domingues MR, Segundo MA. Lab-on-Valve Automated and Miniaturized Assessment of Nanoparticle Concentration Based on Light-Scattering. Anal Chem 2023; 95:4619-4626. [PMID: 36802495 PMCID: PMC10018450 DOI: 10.1021/acs.analchem.2c04631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
Abstract
Nanoparticles (NPs) concentration directly impacts the dose delivered to target tissues by nanocarriers. The evaluation of this parameter is required during NPs developmental and quality control stages, for setting dose-response correlations and for evaluating the reproducibility of the manufacturing process. Still, faster and simpler procedures, dismissing skilled operators and post-analysis conversions are needed to quantify NPs for research and quality control operations, and to support result validation. Herein, a miniaturized automated ensemble method to measure NPs concentration was established under the lab-on-valve (LOV) mesofluidic platform. Automatic NPs sampling and delivery to the LOV detection unit were set by flow programming. NPs concentration measurements were based on the decrease in the light transmitted to the detector due to the light scattered by NPs when passing through the optical path. Each analysis was accomplished in 2 min, rendering a determination throughput of 30 h-1 (6 samples h-1 for n = 5) and only requiring 30 μL (≈0.03 g) of NPs suspension. Measurements were performed on polymeric NPs, as these represent one of the major classes of NPs under development for drug-delivery aims. Determinations for polystyrene NPs (of 100, 200, and 500 nm) and for NPs made of PEGylated poly-d,l-lactide-co-glycolide (PEG-PLGA, a biocompatible FDA-approved polymer) were accomplished within 108-1012 particles mL-1 range, depending on the NPs size and composition. NPs size and concentration were maintained during analysis, as verified for NPs eluted from the LOV by particle tracking analysis (PTA). Moreover, concentration measurements for PEG-PLGA NPs loaded with an anti-inflammatory drug, methotrexate (MTX), after their incubation in simulated gastric and intestinal fluids were successfully achieved (recovery values of 102-115%, as confirmed by PTA), showing the suitability of the proposed method to support the development of polymeric NPs targeting intestinal delivery.
Collapse
Affiliation(s)
- Sara S Marques
- LAQV, REQUIMTE, University of Porto, Department of Chemical Sciences, Faculty of Pharmacy, R. Jorge Viterbo Ferreira 228, 4050-313 Porto, Portugal
| | - Inês I Ramos
- LAQV, REQUIMTE, University of Porto, Department of Chemical Sciences, Faculty of Pharmacy, R. Jorge Viterbo Ferreira 228, 4050-313 Porto, Portugal
| | - Carla Silva
- Centre of Biological Engineering (CEB), University of Minho, 4710-057 Braga, Portugal.,LABBELS - Associate Laboratory, 4710-057 Braga, Guimarães Portugal
| | - Luisa Barreiros
- LAQV, REQUIMTE, University of Porto, Department of Chemical Sciences, Faculty of Pharmacy, R. Jorge Viterbo Ferreira 228, 4050-313 Porto, Portugal.,School of Health, Polytechnic Institute of Porto, R. Dr. António Bernardino de Almeida 400, 4200-072 Porto, Portugal
| | - Maria R Domingues
- CESAM-Centre for Environmental and Marine Studies, Department of Chemistry, Santiago University Campus, University of Aveiro, 3810-193 Aveiro, Portugal.,Mass Spectrometry Centre, LAQV REQUIMTE, Department of Chemistry, Santiago University Campus, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Marcela A Segundo
- LAQV, REQUIMTE, University of Porto, Department of Chemical Sciences, Faculty of Pharmacy, R. Jorge Viterbo Ferreira 228, 4050-313 Porto, Portugal
| |
Collapse
|
3
|
Pena-Pereira F, Bendicho C, Pavlović DM, Martín-Esteban A, Díaz-Álvarez M, Pan Y, Cooper J, Yang Z, Safarik I, Pospiskova K, Segundo MA, Psillakis E. Miniaturized analytical methods for determination of environmental contaminants of emerging concern - A review. Anal Chim Acta 2020; 1158:238108. [PMID: 33863416 DOI: 10.1016/j.aca.2020.11.040] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 11/26/2020] [Accepted: 11/27/2020] [Indexed: 01/09/2023]
Abstract
The determination of contaminants of emerging concern (CECs) in environmental samples has become a challenging and critical issue. The present work focuses on miniaturized analytical strategies reported in the literature for the determination of CECs. The first part of the review provides brief overview of CECs whose monitoring in environmental samples is of particular significance, namely personal care products, pharmaceuticals, endocrine disruptors, UV-filters, newly registered pesticides, illicit drugs, disinfection by-products, surfactants, high technology rare earth elements, and engineered nanomaterials. Besides, an overview of downsized sample preparation approaches reported in the literature for the determination of CECs in environmental samples is provided. Particularly, analytical methodologies involving microextraction approaches used for the enrichment of CECs are discussed. Both solid phase- and liquid phase-based microextraction techniques are highlighted devoting special attention to recently reported approaches. Special emphasis is placed on newly developed materials used for extraction purposes in microextraction techniques. In addition, recent contributions involving miniaturized analytical flow techniques for the determination of CECs are discussed. Besides, the strengths, weaknesses, opportunities and threats of point of need and portable devices have been identified and critically compared with chromatographic methods coupled to mass chromatography. Finally, challenging aspects regarding miniaturized analytical methods for determination of CECs are critically discussed.
Collapse
Affiliation(s)
- Francisco Pena-Pereira
- Centro de Investigación Mariña, Universidade de Vigo, Departamento de Química Analítica e Alimentaria, Grupo QA2, Edificio CC Experimentais, Campus de Vigo, As Lagoas, Marcosende, 36310, Vigo, Spain.
| | - Carlos Bendicho
- Centro de Investigación Mariña, Universidade de Vigo, Departamento de Química Analítica e Alimentaria, Grupo QA2, Edificio CC Experimentais, Campus de Vigo, As Lagoas, Marcosende, 36310, Vigo, Spain.
| | - Dragana Mutavdžić Pavlović
- Department of Analytical Chemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev Trg 19, Zagreb, 10000, Croatia
| | - Antonio Martín-Esteban
- Departamento de Medio Ambiente y Agronomía, INIA, Carretera de A Coruña Km 7.5, Madrid, E-28040, Spain
| | - Myriam Díaz-Álvarez
- Departamento de Medio Ambiente y Agronomía, INIA, Carretera de A Coruña Km 7.5, Madrid, E-28040, Spain
| | - Yuwei Pan
- Cranfield Water Science Institute, Cranfield University, Cranfield, MK43 0AL, United Kingdom; School of Engineering, University of Glasgow, G12 8LT, United Kingdom
| | - Jon Cooper
- School of Engineering, University of Glasgow, G12 8LT, United Kingdom
| | - Zhugen Yang
- Cranfield Water Science Institute, Cranfield University, Cranfield, MK43 0AL, United Kingdom
| | - Ivo Safarik
- Department of Nanobiotechnology, Biology Centre, ISB, CAS, Na Sadkach 7, 370 05, Ceske Budejovice, Czech Republic; Regional Centre of Advanced Technologies and Materials, Palacky University, Slechtitelu 27, 783 71, Olomouc, Czech Republic; Department of Magnetism, Institute of Experimental Physics, SAS, Watsonova 47, 040 01, Kosice, Slovakia
| | - Kristyna Pospiskova
- Department of Nanobiotechnology, Biology Centre, ISB, CAS, Na Sadkach 7, 370 05, Ceske Budejovice, Czech Republic; Regional Centre of Advanced Technologies and Materials, Palacky University, Slechtitelu 27, 783 71, Olomouc, Czech Republic
| | - Marcela A Segundo
- LAQV/REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, R Jorge Viterbo Ferreira, 228, 4050-313, Porto, Portugal
| | - Elefteria Psillakis
- Laboratory of Aquatic Chemistry, School of Environmental Engineering, Polytechnioupolis, Technical University of Crete, GR-73100, Chania, Crete, Greece
| |
Collapse
|
6
|
Kołacińska K, Samczyński Z, Dudek J, Bojanowska-Czajka A, Trojanowicz M. A comparison study on the use of Dowex 1 and TEVA-resin in determination of 99Tc in environmental and nuclear coolant samples in a SIA system with ICP-MS detection. Talanta 2018; 184:527-536. [PMID: 29674079 DOI: 10.1016/j.talanta.2018.03.034] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 03/09/2018] [Accepted: 03/12/2018] [Indexed: 11/20/2022]
Abstract
This work refers to a comparative study of sorbents widely used in determinations of 99Tc such as TEVA resin and Dowex 1. Despite having a similar functional group of quaternary amines, both materials represent different chromatographic methods-extraction (TEVA resin) and anion exchange (Dowex 1)-which provides a diverse range of their properties significant in determination of 99Tc in flow conditions. The comparative tests, carried out in a SIA-LOV (Sequential Injection Analysis-Lab-on-Valve) system combined with mass spectrometric (ICP-MS) detection, considered several factors that are crucial from the standpoint of resin´s utility such as sorption capacity, durability, or selectivity, critical in 99Tc separation from interferences. The developed and optimized analytical procedure based on the application of the TEVA resin provided determinations of 99Tc at minimum detectable limit (MDL) 6.00 mBq L-1 in 50 min and has been successfully employed in analyses of samples from nuclear industrial and research units (reactor coolant and sewage) as well as from the river surrounding the nuclear reactor. The method proved to be sufficient for routine analysis of water samples in accordance with EPA standards. The reliability of the method was confirmed in the analysis of the BH standard provided by the NPL for inter-laboratory proficiency tests. The 99Tc recovery for all real samples was evaluated as 80-100%.
Collapse
Affiliation(s)
- Kamila Kołacińska
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw, Poland.
| | - Zbigniew Samczyński
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw, Poland
| | - Jakub Dudek
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw, Poland
| | - Anna Bojanowska-Czajka
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw, Poland
| | - Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw, Poland; Department of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| |
Collapse
|