1
|
Jiao D, Jiao F, Qian ZJ, Luo L, Wang Y, Shen YD, Lei HT, Xu ZL. Formation and Detection of Gizzerosine in Animal Feed Matrices: Progress and Perspectives. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:3247-3258. [PMID: 38320115 DOI: 10.1021/acs.jafc.3c05973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2024]
Abstract
Gizzerosine is responsible for gizzard erosion and black vomit, owing to excessive gastric acid secretion in poultry. It is a biogenic amine that forms during feed processing. Gizzerosine, a derivative of histamine, is a serious threat to animal feed safety and poultry production because it is more potent after ingestion and more harmful to poultry than histamine. The difficulty of obtaining gizzerosine and the lack of simple, rapid, and sensitive in vitro detection techniques have hindered studies on the effects of gizzerosine on gizzard health and poultry production. In this review, we evaluated the natural formation and the chemical synthesis methods of gizzerosine and introduced seven detection methods and their principles for analyzing gizzerosine. This review summarizes the issues of gizzerosine research and suggests methods for the future development of gizzerosine detection methods.
Collapse
Affiliation(s)
- Di Jiao
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Fan Jiao
- Gong Yi Shi Di San Chu Ji Zhong Xue, Zhengzhou 451200, China
| | - Zhen-Jie Qian
- Guangzhou Institute of Food Inspection, Guangzhou, 510410, China
| | - Lin Luo
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Yu Wang
- Guangzhou Institute of Food Inspection, Guangzhou, 510410, China
| | - Yu-Dong Shen
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Hong-Tao Lei
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| | - Zhen-Lin Xu
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou 510642, China
| |
Collapse
|
2
|
Lin X, Fang Y, Chen Q, Guo Z, Chen X, Chen X. Magnetically actuated microfluidic chip combined with a G-quadruplex DNAzyme-based fluorescent/colorimetric sensor for the dual-mode detection of ochratoxin A in wheat. Talanta 2024; 267:125273. [PMID: 37804790 DOI: 10.1016/j.talanta.2023.125273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Revised: 09/28/2023] [Accepted: 10/02/2023] [Indexed: 10/09/2023]
Abstract
In this work, a portable fluorescent/colorimetric sensor based on G-quadruplex DNAzyme was constructed to achieve rapid and dual-mode detection of ochratoxin A (OTA) in wheat. OTA aptamers coupled with magnetic beads (MBs) can self-assemble with two segments of DNA and hemin to form a G-quadruplex DNAzyme structure that can catalyze the oxidation of Amplex Red (ADHP) with H2O2, making the solution red and producing strong fluorescence in solution. However, in the presence of OTA, the structure of the G-quadruplex DNAzyme was damaged, resulting in reduced catalytic activity. According to the principle of detection, a magnet-controlled chip integrating the reaction, washing, and detection was designed in this study. Shuttling the MB-DNAzyme probes onto a magnetically controlled chip considerably reduced the background signal and improved the detection efficiency and sensitivity. In addition, a portable fluorescence and colorimetric detection platform was built for on-site OTA detection.
Collapse
Affiliation(s)
- Xueqi Lin
- College of Ocean Food and Biological Engineering, Jimei University, Xiamen, 361021, China.
| | - Yuwen Fang
- College of Ocean Food and Biological Engineering, Jimei University, Xiamen, 361021, China.
| | - Quansheng Chen
- College of Ocean Food and Biological Engineering, Jimei University, Xiamen, 361021, China.
| | - Zhiyong Guo
- Institute of Analytical Technology and Smart Instruments and Colleague of Environment and Public Healthy, Xiamen Huaxia University, Xiamen, 361024, China.
| | - Xi Chen
- State Key Laboratory of Marine Environmental Science, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Xiaomei Chen
- College of Ocean Food and Biological Engineering, Jimei University, Xiamen, 361021, China.
| |
Collapse
|
3
|
Wang Y, Li Y, Liu C, Dong N, Liu D, You T. Laser induced graphene electrochemical aptasensor based on tetrahedral DNA for ultrasensitive on-site detection of microcystin-LR. Biosens Bioelectron 2023; 239:115610. [PMID: 37625203 DOI: 10.1016/j.bios.2023.115610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 07/31/2023] [Accepted: 08/16/2023] [Indexed: 08/27/2023]
Abstract
The development of accurate and reliable sensor for on-site detection of microcystin-LR (MC-LR), one of hazardous environmental pollutants, is highly required. Herein, a laser induced graphene (LIG)-based electrochemical aptasensor for sensitive on-site detection of MC-LR was reported. LIG electrode, the substrate of aptasensor, was prepared via thermal transfer with ethylene-vinyl acetate copolymer, and LIG acted as quasi-reference electrode to replace conventional Ag/AgCl electrode for better operability and robustness. LIG electrode provided large surface area to assemble tetrahedral DNA to absorb methylene blue (MB) for the signal amplification. For detection, the specific recognition of MC-LR with aptamer led to the stripping of tetrahedral DNA complex and further the decreased redox current of MB (IMB). Consequently, the fabricated aptasensor offered high analytical performance for MC-LR detection with a linear range of 1 × 10-2-1 × 105 pM and a detection limit of 3 × 10-3 pM, which was successfully used for water sample analysis with comparable reliability and accuracy of standard method. Furthermore, a portable detection platform by coupling of LIG-based electrochemical aptasensor with electrochemical workstation was constructed for on-site detection of MC-LR. This work offers a novel method for the on-site monitoring of MC-LR, which promotes the investigation of LIG-based electrochemical biosensing in the field of environmental analysis.
Collapse
Affiliation(s)
- Yuan Wang
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, China
| | - Yuye Li
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, China
| | - Chang Liu
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, China
| | - Na Dong
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, China
| | - Dong Liu
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, China.
| | - Tianyan You
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, China
| |
Collapse
|
4
|
Recent developments in biosensing strategies for the detection of small molecular contaminants to ensure food safety in aquaculture and fisheries. Trends Food Sci Technol 2023. [DOI: 10.1016/j.tifs.2023.01.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
5
|
Zhu L, Dong XX, Gao CB, Gai Z, He YX, Qian ZJ, Liu Y, Lei HT, Sun YM, Xu ZL. Development of a highly sensitive and selective electrochemical immunosensor for controlling of rhodamine B abuse in food samples. Food Control 2022. [DOI: 10.1016/j.foodcont.2021.108662] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
6
|
Shi Y, Ye P, Yang K, Meng J, Guo J, Pan Z, Bayin Q, Zhao W. Application of Microfluidics in Immunoassay: Recent Advancements. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:2959843. [PMID: 34326976 PMCID: PMC8302407 DOI: 10.1155/2021/2959843] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 06/30/2021] [Indexed: 12/14/2022]
Abstract
In recent years, point-of-care testing has played an important role in immunoassay, biochemical analysis, and molecular diagnosis, especially in low-resource settings. Among various point-of-care-testing platforms, microfluidic chips have many outstanding advantages. Microfluidic chip applies the technology of miniaturizing conventional laboratory which enables the whole biochemical process including reagent loading, reaction, separation, and detection on the microchip. As a result, microfluidic platform has become a hotspot of research in the fields of food safety, health care, and environmental monitoring in the past few decades. Here, the state-of-the-art application of microfluidics in immunoassay in the past decade will be reviewed. According to different driving forces of fluid, microfluidic platform is divided into two parts: passive manipulation and active manipulation. In passive manipulation, we focus on the capillary-driven microfluidics, while in active manipulation, we introduce pressure microfluidics, centrifugal microfluidics, electric microfluidics, optofluidics, magnetic microfluidics, and digital microfluidics. Additionally, within the introduction of each platform, innovation of the methods used and their corresponding performance improvement will be discussed. Ultimately, the shortcomings of different platforms and approaches for improvement will be proposed.
Collapse
Affiliation(s)
- Yuxing Shi
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Peng Ye
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Kuojun Yang
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Jie Meng
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Jiuchuan Guo
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Zhixiang Pan
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Qiaoge Bayin
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Wenhao Zhao
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| |
Collapse
|
7
|
Shu B, Lin L, Wu B, Huang E, Wang Y, Li Z, He H, Lei X, Xu B, Liu D. A pocket-sized device automates multiplexed point-of-care RNA testing for rapid screening of infectious pathogens. Biosens Bioelectron 2021; 181:113145. [PMID: 33752027 DOI: 10.1016/j.bios.2021.113145] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 01/13/2021] [Accepted: 03/01/2021] [Indexed: 01/03/2023]
Abstract
Rapid screening of infectious pathogens at the point-of-care (POC) is ideally low-cost, portable, easy to use, and capable of multiplex detection with high sensitivity. However, satisfying all these features in a single device without compromise remains a challenging task. Here, we introduce an ultraportable, automated RNA amplification testing device that allows rapid screening of infectious pathogens from clinical samples. In this device, 3D-printed structural parts incorporated with off-the-shelf mechanic/electronic components are utilized to create an inexpensive and automated droplet manipulation platform. On this platform, a simple configuration that couples a linear displacement of the chip with a tunable magnet array allows parallel and versatile droplet operations, including mixing, splitting, transporting, and merging. By exploiting a multi-channel droplet array chip to preload necessary reagents in "water-in-oil" format, bacteria lysis, RNA extraction and amplification are seamlessly integrated and implemented by the combination of droplet operations. Furthermore, visual readout and geometrically-multiplexed quantitative detection are provided by an integrated wireless video camera-enabled wide-field fluorescence imaging. We demonstrated that this droplet-based device could have a shorter RNA extraction time (12 min) and lower detection limits for pathogenic RNA (approaching to 102 copies per reaction). We also verified its clinical applicability for the rapid screening of four sexually transmitted pathogens from urine specimens. Results show that the sample-to-answer assay could be completed in approximately 42 min, with 100% concordance with the laboratory-based molecular testing. The exhibiting features may render this microdevice an easily accessible POC molecular diagnostic platform for infectious disease, especially in resource-limited settings.
Collapse
Affiliation(s)
- Bowen Shu
- Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China; Clinical Molecular Medicine and Molecular Diagnosis Key Laboratory of Guangdong Province, Guangzhou, 510180, China; Guangdong Engineering Technology Research Center of Microfluidic Chip Medical Diagnosis, Guangzhou, 510180, China
| | - Ling Lin
- Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China
| | - Bin Wu
- Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China; Clinical Molecular Medicine and Molecular Diagnosis Key Laboratory of Guangdong Province, Guangzhou, 510180, China; Guangdong Engineering Technology Research Center of Microfluidic Chip Medical Diagnosis, Guangzhou, 510180, China
| | - Enqi Huang
- Department of Laboratory Medicine, Guangzhou First People's Hospital, Guangzhou Medical University, Guangzhou, 510180, China
| | - Yu Wang
- Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China; Clinical Molecular Medicine and Molecular Diagnosis Key Laboratory of Guangdong Province, Guangzhou, 510180, China; Guangdong Engineering Technology Research Center of Microfluidic Chip Medical Diagnosis, Guangzhou, 510180, China
| | - Zhujun Li
- Department of Laboratory Medicine, Guangzhou First People's Hospital, Guangzhou Medical University, Guangzhou, 510180, China
| | - Haoyan He
- Department of Laboratory Medicine, Guangzhou First People's Hospital, Guangzhou Medical University, Guangzhou, 510180, China
| | - Xiuxia Lei
- Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China; Clinical Molecular Medicine and Molecular Diagnosis Key Laboratory of Guangdong Province, Guangzhou, 510180, China
| | - Banglao Xu
- Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China; Department of Laboratory Medicine, Guangzhou First People's Hospital, Guangzhou Medical University, Guangzhou, 510180, China; Clinical Molecular Medicine and Molecular Diagnosis Key Laboratory of Guangdong Province, Guangzhou, 510180, China.
| | - Dayu Liu
- Department of Laboratory Medicine, Guangzhou First People's Hospital, School of Medicine, South China University of Technology, Guangzhou, 510180, China; Department of Laboratory Medicine, Guangzhou First People's Hospital, Guangzhou Medical University, Guangzhou, 510180, China; Clinical Molecular Medicine and Molecular Diagnosis Key Laboratory of Guangdong Province, Guangzhou, 510180, China; Guangdong Engineering Technology Research Center of Microfluidic Chip Medical Diagnosis, Guangzhou, 510180, China.
| |
Collapse
|
8
|
Carrasco-Correa EJ, Simó-Alfonso EF, Herrero-Martínez JM, Miró M. The emerging role of 3D printing in the fabrication of detection systems. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2020.116177] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
9
|
Magnet-actuated droplet microfluidic immunosensor coupled with gel imager for detection of microcystin-LR in aquatic products. Talanta 2020; 219:121329. [DOI: 10.1016/j.talanta.2020.121329] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 05/10/2020] [Accepted: 06/23/2020] [Indexed: 12/19/2022]
|