1
|
Pei G, Azimi P, Rim D, Allen JG. A CFD study on the effect of portable air cleaner placement on airborne infection control in a classroom. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2024; 26:1476-1488. [PMID: 38973672 PMCID: PMC11410509 DOI: 10.1039/d4em00114a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/09/2024]
Abstract
The utilization of portable air cleaners (PACs) is a recommended supplemental approach to help remove airborne pathogens and mitigate disease transmission in learning environments. To improve PAC effectiveness, science-based information is needed to optimize their implementation strategies such as the deployment location, height, and number of PACs. In this study, we developed a Computational Fluid Dynamics (CFD) model to assess how PACs perform in occupied classrooms equipped with displacement and mixing ventilation systems. The results show that PACs with a flow rate of 2.6 h-1 reduce the mean aerosol intake of all students by up to 66%. A key benefit of using PACs is to facilitate air mixing and movement in indoor environments with inadequate ventilation, thereby effectively reducing high aerosol concentrations near the infector. Furthermore, our results highlight the impact of PAC location on its performance. PACs achieve the best effectiveness when placed closed to the infector (within a distance <3 m). In the absence of knowing who is infected, deploying a PAC at the center of the room is recommended. Moreover, adjusting PAC flow discharge height to the breathing height of occupants (e.g., 0.9-1.2 m for seated people) can enhance their effectiveness in spaces with poor air mixing.
Collapse
Affiliation(s)
- Gen Pei
- Environmental Health Department, Harvard T. H. Chan School of Public Health, Boston, MA 02115, USA.
| | - Parham Azimi
- Environmental Health Department, Harvard T. H. Chan School of Public Health, Boston, MA 02115, USA.
| | - Donghyun Rim
- Architectural Engineering Department, Pennsylvania State University, University Park, PA 16802, USA
| | - Joseph G Allen
- Environmental Health Department, Harvard T. H. Chan School of Public Health, Boston, MA 02115, USA.
| |
Collapse
|
2
|
Harding-Smith E, Davies HL, O'Leary C, Winkless R, Shaw M, Dillon T, Jones B, Carslaw N. The impact of surfaces on indoor air chemistry following cooking and cleaning. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2024. [PMID: 39268696 DOI: 10.1039/d4em00410h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/17/2024]
Abstract
Cooking and cleaning are common sources of indoor air pollutants, including volatile organic compounds (VOCs). The chemical fate of VOCs indoors is determined by both gas-phase and multi-phase chemistry, and can result in the formation of potentially hazardous secondary pollutants. Chemical interactions at the gas-surface boundary play an important role in indoor environments due to the characteristically high surface area to volume ratios (SAVs). This study first characterises the VOC emissions from a typical cooking and cleaning activity in a semi-realistic domestic kitchen, using real-time measurements. While cooking emitted a larger amount of VOCs overall, both cooking and cleaning were sources of chemically reactive monoterpenes (peak mixing ratios 7 ppb and 2 ppb, respectively). Chemical processing of the VOC emissions from sequential cooking and cleaning activities was then simulated in a kitchen using a detailed chemical model. Results showed that ozone (O3) deposition was most effective onto plastic and soft furnishings, while wooden surfaces were the most effective at producing formaldehyde following multi-phase chemistry. Subsequent modelling of cooking and cleaning emissions using a range of measured kitchen SAVs revealed that indoor oxidant levels and the subsequent chemistry, are strongly influenced by the total and material-specific SAV of the room. O3 mixing ratios ranged from 1.3-7.8 ppb across 9 simulated kitchens, with higher concentrations of secondary pollutants observed at higher O3 concentration. Increased room volume, decreased total SAV, decreased SAVs of plastic and soft furnishings, and increased wood SAV contributed to elevated formaldehyde and total peroxyacetyl nitrates (PANs) mixing ratios, of up to 1548 ppt and 643 ppt, respectively, following cooking and cleaning. Therefore, the size and material composition of indoor environments has the potential to impact the chemical processing of VOC emissions from common occupant activities.
Collapse
Affiliation(s)
- Ellen Harding-Smith
- Department of Environment and Geography, University of York, UK.
- Wolfson Atmospheric Chemistry Laboratory, Department of Chemistry, University of York, UK
| | - Helen L Davies
- Department of Environment and Geography, University of York, UK.
| | - Catherine O'Leary
- Wolfson Atmospheric Chemistry Laboratory, Department of Chemistry, University of York, UK
| | - Ruth Winkless
- Wolfson Atmospheric Chemistry Laboratory, Department of Chemistry, University of York, UK
| | - Marvin Shaw
- Wolfson Atmospheric Chemistry Laboratory, Department of Chemistry, University of York, UK
- National Centre for Atmospheric Science, University of York, UK
| | - Terry Dillon
- Wolfson Atmospheric Chemistry Laboratory, Department of Chemistry, University of York, UK
| | - Benjamin Jones
- Department of Architecture and Built Environment, University of Nottingham, UK
| | - Nicola Carslaw
- Department of Environment and Geography, University of York, UK.
| |
Collapse
|
3
|
Tian Y, Xu P, Wu X, Gong Z, Yang X, Zhu H, Zhang J, Hu Y, Li G, Sang N, Yue H. Lung injuries induced by ozone exposure in female mice: Potential roles of the gut and lung microbes. ENVIRONMENT INTERNATIONAL 2024; 183:108422. [PMID: 38217903 DOI: 10.1016/j.envint.2024.108422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 12/28/2023] [Accepted: 01/03/2024] [Indexed: 01/15/2024]
Abstract
Ozone (O3) is one of the most harmful pollutants affecting health. However, the potential effects of O3 exposure on microbes in the gut-lung axis related to lung injuries remain elusive. In this study, female mice were exposed to 0-, 0.5- and 1-ppm O3 for 28 days, followed by routine blood tests, lung function tests and histopathological examination of the colon, nasal cavity and lung. Mouse faeces and lungs were collected for 16s rRNA sequencing to assess the overall microbiological profile and screen for key differential enriched microbes (DEMs). The key DEMs in faecal samples were Butyricimonas, Rikenellaceae RC9 and Escherichia-Shigella, whereas those in lung samples were DNF00809, Fluviicola, Bryobacter, Family XII AD3011 group, Sharpea, MND1 and unclassified Phycisphaeraceae. After a search in microbe-disease databases, these key DEMs were found to be associated with lung diseases such as lung neoplasms, cystic fibrosis, pneumonia, chronic obstructive pulmonary disease, respiratory distress syndrome and bronchiectasis. Subsequently, we used transcriptomic data from Gene Expression Omnibus (GEO) with exposure conditions similar to those in this study to cross-reference with Comparative Toxicogenomic Database (CTD). Il-6 and Ccl2 were identified as the key causative genes and were validated. The findings of this study suggest that exposure to O3 leads to significant changes in the microbial composition of the gut and lungs. These changes are associated with increased levels of inflammatory factors in the lungs and impaired lung function, resulting in an increased risk of lung disease. Altogether, this study provides novel insights into the role of microbes present in the gut-lung axis in O3 exposure-induced lung injury.
Collapse
Affiliation(s)
- Yuchai Tian
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Pengchong Xu
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Xiaoyun Wu
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Zhihua Gong
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China; Department of Clinical Laboratory, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tong ji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, Shanxi 030032, PR China; Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, PR China
| | - Xiaowen Yang
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Huizhen Zhu
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Jiyue Zhang
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Yangcheng Hu
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Guangke Li
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Nan Sang
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Huifeng Yue
- College of Environment and Resource, Research Center of Environment and Health, Shanxi University, Taiyuan, Shanxi 030006, PR China.
| |
Collapse
|
4
|
Tang X, Gambier C, López-Gálvez N, Padilla S, Rapp VH, Russell ML, Klivansky LM, Mayorga R, Perrino C, Gundel LA, Hoh E, Dodder NG, Hammond SK, Zhang H, Matt GE, Quintana PJE, Destaillats H. Remediation of Thirdhand Tobacco Smoke with Ozone: Probing Deep Reservoirs in Carpets. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023. [PMID: 37366549 DOI: 10.1021/acs.est.3c01628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2023]
Abstract
We assessed the efficacy of ozonation as an indoor remediation strategy by evaluating how a carpet serves as a sink and long-term source of thirdhand tobacco smoke (THS) while protecting contaminants absorbed in deep reservoirs by scavenging ozone. Specimens from unused carpet that was exposed to smoke in the lab ("fresh THS") and contaminated carpets retrieved from smokers' homes ("aged THS") were treated with 1000 ppb ozone in bench-scale tests. Nicotine was partially removed from fresh THS specimens by volatilization and oxidation, but it was not significantly eliminated from aged THS samples. By contrast, most of the 24 polycyclic aromatic hydrocarbons detected in both samples were partially removed by ozone. One of the home-aged carpets was installed in an 18 m3 room-sized chamber, where its nicotine emission rate was 950 ng day-1 m-2. In a typical home, such daily emissions could amount to a non-negligible fraction of the nicotine released by smoking one cigarette. The operation of a commercial ozone generator for a total duration of 156 min, reaching concentrations up to 10,000 ppb, did not significantly reduce the carpet nicotine loading (26-122 mg m-2). Ozone reacted primarily with carpet fibers, rather than with THS, leading to short-term emissions of aldehydes and aerosol particles. Hence, by being absorbed deeply into carpet fibers, THS constituents can be partially shielded from ozonation.
Collapse
Affiliation(s)
- Xiaochen Tang
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Clément Gambier
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Nicolás López-Gálvez
- School of Public Health, San Diego State University, San Diego, California 92182, United States
| | - Samuel Padilla
- School of Public Health, San Diego State University, San Diego, California 92182, United States
| | - Vi H Rapp
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Marion L Russell
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Liana M Klivansky
- Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Raphael Mayorga
- Department of Chemistry, University of California Riverside, Riverside, California 92521, United States
| | - Charles Perrino
- School of Public Health, University of California Berkeley, Berkeley, California 94720, United States
| | - Lara A Gundel
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Eunha Hoh
- School of Public Health, San Diego State University, San Diego, California 92182, United States
| | - Nathan G Dodder
- School of Public Health, San Diego State University, San Diego, California 92182, United States
| | - S Katharine Hammond
- School of Public Health, University of California Berkeley, Berkeley, California 94720, United States
| | - Haofei Zhang
- Department of Chemistry, University of California Riverside, Riverside, California 92521, United States
| | - George E Matt
- Department of Psychology, San Diego State University, San Diego, California 92182, United States
| | - Penelope J E Quintana
- School of Public Health, San Diego State University, San Diego, California 92182, United States
| | - Hugo Destaillats
- Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| |
Collapse
|