1
|
Lynch P, Das A, Alam S, Rich CC, Frontiera RR. Mastering Femtosecond Stimulated Raman Spectroscopy: A Practical Guide. ACS PHYSICAL CHEMISTRY AU 2024; 4:1-18. [PMID: 38283786 PMCID: PMC10811773 DOI: 10.1021/acsphyschemau.3c00031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 10/02/2023] [Accepted: 10/02/2023] [Indexed: 01/30/2024]
Abstract
Femtosecond stimulated Raman spectroscopy (FSRS) is a powerful nonlinear spectroscopic technique that probes changes in molecular and material structure with high temporal and spectral resolution. With proper spectral interpretation, this is equivalent to mapping out reactive pathways on highly anharmonic excited-state potential energy surfaces with femtosecond to picosecond time resolution. FSRS has been used to examine structural dynamics in a wide range of samples, including photoactive proteins, photovoltaic materials, plasmonic nanostructures, polymers, and a range of others, with experiments performed in multiple groups around the world. As the FSRS technique grows in popularity and is increasingly implemented in user facilities, there is a need for a widespread understanding of the methodology and best practices. In this review, we present a practical guide to FSRS, including discussions of instrumentation, as well as data acquisition and analysis. First, we describe common methods of generating the three pulses required for FSRS: the probe, Raman pump, and actinic pump, including a discussion of the parameters to consider when selecting a beam generation method. We then outline approaches for effective and efficient FSRS data acquisition. We discuss common data analysis techniques for FSRS, as well as more advanced analyses aimed at extracting small signals on a large background. We conclude with a discussion of some of the new directions for FSRS research, including spectromicroscopy. Overall, this review provides researchers with a practical handbook for FSRS as a technique with the aim of encouraging many scientists and engineers to use it in their research.
Collapse
Affiliation(s)
- Pauline
G. Lynch
- Department
of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Aritra Das
- Department
of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Shahzad Alam
- Department
of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Christopher C. Rich
- Department
of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Renee R. Frontiera
- Department
of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
2
|
Mandal A, Ziegler LD. Vibrational line shape effects in plasmon-enhanced stimulated Raman spectroscopies. J Chem Phys 2021; 155:194701. [PMID: 34800946 DOI: 10.1063/5.0067301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
A density matrix treatment of plasmon-enhanced (PE) stimulated Raman spectroscopies is developed. Specifically, PE stimulated Raman Gain/Loss (PE-SRG/L) and coherent anti-Stokes Raman scattering (PE-CARS) due to monochromatic excitation and PE femtosecond stimulated Raman spectroscopy (PE-FSRS) are considered. A Lorentz oscillator model is used to explicitly describe the time dependence of plasmon-enhanced optical fields. These temporal characteristics are required for a density matrix based description of all plasmon-enhanced nonlinear molecular spectroscopies. Dispersive vibrational line shapes in PE-SRG/L and PE-FSRS spectra are shown to result primarily from terms proportional to the square of the complex optical field enhancement factor. The dependence on the plasmon resonance, picosecond and femtosecond pulse characteristics, and molecular vibrational properties are evident in the density matrix derived PE-FSRS intensity expression. The difference in signal detection mechanisms accounts for the lack of dispersive line shapes in PE spontaneous Raman spectroscopy. This density matrix treatment of PE-FSRS line shapes is compared with prior coupled wave results.
Collapse
Affiliation(s)
- Aritra Mandal
- Intel Corporation, 2501 NW 229th Ave., Hillsboro, Oregon 97124, USA
| | - L D Ziegler
- Department of Chemistry, Photonics Center Boston University, Boston, Massachusetts 02215, USA
| |
Collapse
|
3
|
Burns KH, Srivastava P, Elles CG. Absolute Cross Sections of Liquids from Broadband Stimulated Raman Scattering with Femtosecond and Picosecond Pulses. Anal Chem 2020; 92:10686-10692. [PMID: 32598135 DOI: 10.1021/acs.analchem.0c01785] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Broadband stimulated Raman scattering (SRS) is often observed in applications that use nonlinear spectroscopy to probe the composition or dynamics of complex systems. Whether the SRS response is measured intentionally or unintentionally, as a background signal, the relative scattering intensities provide a quantitative measure of the population profile of target molecules. Solvent scattering is a valuable internal reference for determining absolute concentrations in these applications, but accurate cross sections have been reported for only a limited number of transitions in select solvents and were measured using spontaneous Raman scattering with narrowband continuous wave or nanosecond light sources. This work reports the measurement and analysis of absolute Raman scattering cross sections spanning the frequency range of 500-4000 cm-1 for cyclohexane, DMSO, acetonitrile, methanol, water, benzene, and toluene using broadband SRS with femtosecond and picosecond Raman pump pulses at 488 nm. Varying the duration of the Raman pump pulses from ∼80 fs to >1 ps confirms that the cross sections are independent of the spectral bandwidth across the range of ∼250 to <20 cm-1. The cross sections and depolarization ratios measured using broadband SRS agree with the limited number of previously reported values, after accounting for overlapping transitions in the lower-resolution femtosecond and picosecond spectra. The SRS cross sections reported here can be used with confidence as internal reference standards for a wide range of applications, including nonlinear spectroscopy and coherent microscopy measurements using ultrafast lasers.
Collapse
Affiliation(s)
- Kristen H Burns
- Department of Chemistry, University of Kansas, Lawrence, Kansas 66045, United States
| | - Prasenjit Srivastava
- Department of Chemistry, University of Kansas, Lawrence, Kansas 66045, United States
| | - Christopher G Elles
- Department of Chemistry, University of Kansas, Lawrence, Kansas 66045, United States
| |
Collapse
|
4
|
Zong C, Premasiri R, Lin H, Huang Y, Zhang C, Yang C, Ren B, Ziegler LD, Cheng JX. Plasmon-enhanced stimulated Raman scattering microscopy with single-molecule detection sensitivity. Nat Commun 2019; 10:5318. [PMID: 31754221 PMCID: PMC6872561 DOI: 10.1038/s41467-019-13230-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Accepted: 10/22/2019] [Indexed: 12/27/2022] Open
Abstract
Stimulated Raman scattering (SRS) microscopy allows for high-speed label-free chemical imaging of biomedical systems. The imaging sensitivity of SRS microscopy is limited to ~10 mM for endogenous biomolecules. Electronic pre-resonant SRS allows detection of sub-micromolar chromophores. However, label-free SRS detection of single biomolecules having extremely small Raman cross-sections (~10-30 cm2 sr-1) remains unreachable. Here, we demonstrate plasmon-enhanced stimulated Raman scattering (PESRS) microscopy with single-molecule detection sensitivity. Incorporating pico-Joule laser excitation, background subtraction, and a denoising algorithm, we obtain robust single-pixel SRS spectra exhibiting single-molecule events, verified by using two isotopologues of adenine and further confirmed by digital blinking and bleaching in the temporal domain. To demonstrate the capability of PESRS for biological applications, we utilize PESRS to map adenine released from bacteria due to starvation stress. PESRS microscopy holds the promise for ultrasensitive detection and rapid mapping of molecular events in chemical and biomedical systems.
Collapse
Affiliation(s)
- Cheng Zong
- Department of Electrical and Computer Engineering, Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA.,State Key Laboratory of Physical Chemistry of Solid Surfaces, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, College of Chemistry and Chemical Engineering, Xiamen University, 361005, Xiamen, China
| | - Ranjith Premasiri
- Department of Chemistry, Boston University, Boston, MA, 02215, USA.,Photonics Center, Boston University, Boston, MA, 02215, USA
| | - Haonan Lin
- Department of Electrical and Computer Engineering, Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA
| | - Yimin Huang
- Department of Chemistry, Boston University, Boston, MA, 02215, USA
| | - Chi Zhang
- Department of Electrical and Computer Engineering, Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA
| | - Chen Yang
- Department of Chemistry, Boston University, Boston, MA, 02215, USA.,Photonics Center, Boston University, Boston, MA, 02215, USA
| | - Bin Ren
- State Key Laboratory of Physical Chemistry of Solid Surfaces, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, College of Chemistry and Chemical Engineering, Xiamen University, 361005, Xiamen, China
| | - Lawrence D Ziegler
- Department of Chemistry, Boston University, Boston, MA, 02215, USA.,Photonics Center, Boston University, Boston, MA, 02215, USA
| | - Ji-Xin Cheng
- Department of Electrical and Computer Engineering, Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA. .,Department of Chemistry, Boston University, Boston, MA, 02215, USA. .,Photonics Center, Boston University, Boston, MA, 02215, USA.
| |
Collapse
|
5
|
Henry AI, Ueltschi TW, McAnally MO, Van Duyne RP. Spiers Memorial Lecture. Surface-enhanced Raman spectroscopy: from single particle/molecule spectroscopy to ångstrom-scale spatial resolution and femtosecond time resolution. Faraday Discuss 2019; 205:9-30. [PMID: 28906524 DOI: 10.1039/c7fd00181a] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Four decades on, surface-enhanced Raman spectroscopy (SERS) continues to be a vibrant field of research that is growing (approximately) exponentially in scope and applicability while pushing at the ultimate limits of sensitivity, spatial resolution, and time resolution. This introductory paper discusses some aspects related to all four of the themes for this Faraday Discussion. First, the wavelength-scanned SERS excitation spectroscopy (WS-SERES) of single nanosphere oligomers (viz., dimers, trimers, etc.), the distance dependence of SERS, the magnitude of the chemical enhancement mechanism, and the progress toward developing surface-enhanced femtosecond stimulated Raman spectroscopy (SE-FSRS) are discussed. Second, our efforts to develop a continuous, minimally invasive, in vivo glucose sensor based on SERS are highlighted. Third, some aspects of our recent work in single molecule SERS and the translation of that effort to ångstrom-scale spatial resolution in ultrahigh vacuum tip-enhanced Raman spectroscopy (UHV-TERS) and single molecule electrochemistry using electrochemical (EC)-TERS will be presented. Finally, we provide an overview of analytical SERS with our viewpoints on SERS substrates, approaches to address the analyte generality problem (i.e. target molecules that do not spontaneously adsorb and/or have Raman cross sections <10-29 cm2 sr-1), SERS for catalysis, and deep UV-SERS.
Collapse
Affiliation(s)
- Anne-Isabelle Henry
- Departments of Chemistry, Biomedical Engineering, and Applied Physics, Northwestern University, Evanston, IL 60208-3113, USA.
| | | | | | | |
Collapse
|