1
|
Malesys V, Andrieux-Ledier A, Lavenus P, Simon L. Building a cm 2scale CVD graphene-based gas sensor: modelling the kinetic with a three-site adsorption/desorption Langmuir model. NANOTECHNOLOGY 2024; 35:285501. [PMID: 38579693 DOI: 10.1088/1361-6528/ad3b02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 04/05/2024] [Indexed: 04/07/2024]
Abstract
In this article, we aim to develop and study a highly sensitive and selective cm2scale graphene-based gas sensor. We present the technology used to fabricate sensors which integrate monolayer chemical vapour deposition graphene: photolithography and transfer of layers. Characterization techniques (optical microscopy, AFM, micro-Raman spectroscopy, transport electrical measurements) ensure a diagnosis of graphene ribbons and allow good reproducibility of technological processes. We present the results of gas characterizations after a 200 ppm NO2exposure. We propose a novel approach for the modelling of the sensor response with a three-site adsorption/desorption Langmuir model. This innovative way of modelling the sensor response should provide a better understanding of the sensor's kinetic and help to overcome the long response time observed with graphene gas sensors.
Collapse
Affiliation(s)
- V Malesys
- Institut de Sciences des Matériaux de Mulhouse, CNRS-UMR 7361, Université de Haute Alsace, Mulhouse, France
| | | | - P Lavenus
- DPHY, ONERA, Université Paris Saclay, Châtillon, France
| | - L Simon
- Institut de Sciences des Matériaux de Mulhouse, CNRS-UMR 7361, Université de Haute Alsace, Mulhouse, France
| |
Collapse
|
2
|
Saha D, Yu HJ, Wang J, Prateek, Chen X, Tang C, Senger C, Pagaduan JN, Katsumata R, Carter KR, Zhou G, Bai P, Wu N, Watkins JJ. Mesoporous Single Atom-Cluster Fe-N/C Oxygen Evolution Electrocatalysts Synthesized with Bottlebrush Block Copolymer-Templated Rapid Thermal Annealing. ACS APPLIED MATERIALS & INTERFACES 2024; 16:13729-13744. [PMID: 38457643 DOI: 10.1021/acsami.3c18693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/10/2024]
Abstract
Current electrocatalysts for oxygen evolution reaction (OER) are either expensive (such as IrO2, RuO2) or/and exhibit high overpotential as well as sluggish kinetics. This article reports mesoporous earth-abundant iron (Fe)-nitrogen (N) doped carbon electrocatalysts with iron clusters and closely surrounding Fe-N4 active sites. Unique to this work is that the mechanically stable mesoporous carbon-matrix structure (79 nm in pore size) with well-dispersed nitrogen-coordinated Fe single atom-cluster is synthesized via rapid thermal annealing (RTA) within only minutes using a self-assembled bottlebrush block copolymer (BBCP) melamine-formaldehyde resin composite template. The resulting porous structure and domain size can be tuned with the degree of polymerization of the BBCP backbone, which increases the electrochemically active surface area and improves electron transfer and mass transport for an effective OER process. The optimized electrocatalyst shows a required potential of 1.48 V (versus RHE) to obtain the current density of 10 mA/cm2 in 1 M KOH aqueous electrolyte and a small Tafel slope of 55 mV/decade at a given overpotential of 250 mV, which is significantly lower than recently reported earth-abundant electrocatalysts. Importantly, the Fe single-atom nitrogen coordination environment facilitates the surface reconstruction into a highly active oxyhydroxide under OER conditions, as revealed by X-ray photoelectron spectroscopy and in situ Raman spectroscopy, while the atomic clusters boost the single atoms reactive sites to prevent demetalation during the OER process. Density functional theory (DFT) calculations support that the iron nitrogen environment and reconstructed oxyhydroxides are electrocatalytically active sites as the kinetics barrier is largely reduced. This work has opened a new avenue for simple, rapid synthesis of inexpensive, earth-abundant, tailorable, mechanically stable, mesoporous carbon-coordinated single-atom electrocatalysts that can be used for renewable energy production.
Collapse
Affiliation(s)
- Dipankar Saha
- Conte Center for Polymer Research, Department of Polymer Science and Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Hsin-Jung Yu
- Conte Center for Polymer Research, Department of Polymer Science and Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Jiacheng Wang
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Prateek
- Conte Center for Polymer Research, Department of Polymer Science and Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Xiaobo Chen
- Department of Materials Science and Engineering, Binghamton University, State University of New York at Binghamton, Binghamton, New York 13850, United States
| | - Chaoyun Tang
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Claire Senger
- Conte Center for Polymer Research, Department of Polymer Science and Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - James Nicolas Pagaduan
- Conte Center for Polymer Research, Department of Polymer Science and Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Reika Katsumata
- Conte Center for Polymer Research, Department of Polymer Science and Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Kenneth R Carter
- Conte Center for Polymer Research, Department of Polymer Science and Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Guangwen Zhou
- Department of Materials Science and Engineering, Binghamton University, State University of New York at Binghamton, Binghamton, New York 13850, United States
| | - Peng Bai
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Nianqiang Wu
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - James J Watkins
- Conte Center for Polymer Research, Department of Polymer Science and Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| |
Collapse
|
3
|
Ono T, Okuda S, Ushiba S, Kanai Y, Matsumoto K. Challenges for Field-Effect-Transistor-Based Graphene Biosensors. MATERIALS (BASEL, SWITZERLAND) 2024; 17:333. [PMID: 38255502 PMCID: PMC10817696 DOI: 10.3390/ma17020333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 12/28/2023] [Accepted: 01/06/2024] [Indexed: 01/24/2024]
Abstract
Owing to its outstanding physical properties, graphene has attracted attention as a promising biosensor material. Field-effect-transistor (FET)-based biosensors are particularly promising because of their high sensitivity that is achieved through the high carrier mobility of graphene. However, graphene-FET biosensors have not yet reached widespread practical applications owing to several problems. In this review, the authors focus on graphene-FET biosensors and discuss their advantages, the challenges to their development, and the solutions to the challenges. The problem of Debye screening, in which the surface charges of the detection target are shielded and undetectable, can be solved by using small-molecule receptors and their deformations and by using enzyme reaction products. To address the complexity of sample components and the detection mechanisms of graphene-FET biosensors, the authors outline measures against nonspecific adsorption and the remaining problems related to the detection mechanism itself. The authors also introduce a solution with which the molecular species that can reach the sensor surfaces are limited. Finally, the authors present multifaceted approaches to the sensor surfaces that provide much information to corroborate the results of electrical measurements. The measures and solutions introduced bring us closer to the practical realization of stable biosensors utilizing the superior characteristics of graphene.
Collapse
Affiliation(s)
- Takao Ono
- SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan
| | - Satoshi Okuda
- High Frequency & Optical Device Works, Mitsubishi Electric Corporation, 4-1 Mizuhara, Itami, Sendai 664-8641, Japan
| | - Shota Ushiba
- Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Kyoto 617-8555, Japan
| | - Yasushi Kanai
- International Center for Synchrotron Radiation Innovation Smart, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
| | | |
Collapse
|
4
|
Akbar MA, Sharif O, Selvaganapathy PR, Kruse P. Identification and Quantification of Aqueous Disinfectants Using an Array of Carbon Nanotube-Based Chemiresistors. ACS APPLIED ENGINEERING MATERIALS 2023; 1:3040-3052. [PMID: 38031538 PMCID: PMC10683762 DOI: 10.1021/acsaenm.3c00505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 10/08/2023] [Accepted: 10/17/2023] [Indexed: 12/01/2023]
Abstract
Disinfection of water is essential to prevent the growth of pathogens, but at high levels, it can cause harm to human health. Therefore, accurate monitoring of disinfectant concentrations in water is essential to ensure safe drinking water. The use of multiple disinfectants at different stages in water treatment plants makes it necessary to also identify the type and concentrations of all of the disinfectant species present. Here, we demonstrate an effective approach to identify and quantify multiple disinfectants (using the example of free chlorine and potassium permanganate) in water using single-walled carbon nanotube (SWCNT)-based reagent-free chemiresistive sensing arrays. Facile fabrication of chemiresistive devices makes them a popular choice for the implementation of sensor arrays. Our sensing array consists of functionalized and unfunctionalized (blank) SWCNT sensors to distinguish the disinfectants. The distinct responses from the different sensors at varying concentrations and pH can be fitted to the mathematical model of a Langmuir adsorption isotherm separately for each sensor. Blank and functionalized sensors respond through different mechanisms that result in varying responses that are concentration- and pH-dependent. Chemometric techniques such as principal component analysis (PCA) and partial least-squares-discriminant analysis (PLS-DA) were used to analyze the sensor data. PCA showed an excellent separation of the analytes over five different pHs (5.5, 6.5, 7.5, 8.5, and 9.5). PLS-DA provided excellent separability as well as good predictability with a Q2 of 94.26% and an R2 of 95.67% for the five pH regions of the two analytes. This proof-of-concept solid-state chemiresistive sensing array can be developed for specific disinfectants that are commonly used in water treatment plants and can be deployed in water distribution and monitoring facilities. We have demonstrated the applicability of chemiresistive devices in a sensor array format for the first time for aqueous disinfectant monitoring.
Collapse
Affiliation(s)
- Md Ali Akbar
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton ON L8S 4M1, Canada
| | - Omar Sharif
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton ON L8S 4M1, Canada
| | - P. Ravi Selvaganapathy
- Department
of Mechanical Engineering, McMaster University, Hamilton ON L8S 4K1, Canada
- School
of Biomedical Engineering, McMaster University, Hamilton ON L8S 4K1, Canada
| | - Peter Kruse
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton ON L8S 4M1, Canada
| |
Collapse
|
5
|
Darestani-Farahani M, Ma F, Patel V, Selvaganapathy PR, Kruse P. An ion-selective chemiresistive platform as demonstrated for the detection of nitrogen species in water. Analyst 2023; 148:5731-5744. [PMID: 37840463 DOI: 10.1039/d3an01267k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2023]
Abstract
The use of ion-selective electrodes (ISE) is a well-established technique for the detection of ions in aqueous solutions but requires the use of a reference electrode. Here, we introduce a platform of ion-selective chemiresistors for the detection of nitrogen species in water as an alternative method without the need for reference electrodes. Chemiresistors have a sensitive surface that is prone to damage during operation in aqueous solutions. By applying a layer of ion-selective membrane to the surface of the chemiresistive device, the surface becomes protected and highly selective. We demonstrate both anion-selective (NO3-, NO2-) and cation-selective (NH4+) membranes. The nitrate sensors are able to measure nitrate ions in a range of 2.2-220 ppm with a detection limit of 0.3 ppm. The nitrite sensors respond between 67 ppb and 67 ppm of nitrite ions (64 ppb detection limit). The ammonium sensors can measure ammonium concentrations in a wide range from 10 ppb to 100 ppm (0.5 ppb detection limit). The fast responses to nitrate and nitrite are due to a mechanism involving electrostatic gating repulsion between negative charge carriers of the film and anions while ammonium detection arises from two mechanisms based on electrostatic gating repulsion and adsorption of ammonium ions at the surface of the p-doped chemiresistive film. The adsorption phenomenon slows down the recovery time of the ammonium sensor. This sensor design is a new platform to continuously monitor ions in industrial, domestic, and environmental water resources by robust chemiresistive devices.
Collapse
Affiliation(s)
- Maryam Darestani-Farahani
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4M1, Canada
| | - Fanqing Ma
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4M1, Canada
| | - Vinay Patel
- Department of Mechanical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada.
| | | | - Peter Kruse
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4M1, Canada
| |
Collapse
|
6
|
Angizi S, Huang X, Hong L, Akbar MA, Selvaganapathy PR, Kruse P. Defect Density-Dependent pH Response of Graphene Derivatives: Towards the Development of pH-Sensitive Graphene Oxide Devices. NANOMATERIALS 2022; 12:nano12111801. [PMID: 35683657 PMCID: PMC9181870 DOI: 10.3390/nano12111801] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 05/19/2022] [Accepted: 05/20/2022] [Indexed: 02/07/2023]
Abstract
In this study, we demonstrate that a highly pH-sensitive substrate could be fabricated by controlling the type and defect density of graphene derivatives. Nanomaterials from single-layer graphene resembling a defect-free structure to few-layer graphene and graphene oxide with high defect density were used to demonstrate the pH-sensing mechanisms of graphene. We show the presence of three competing mechanisms of pH sensitivity, including the availability of functional groups, the electrochemical double layer, and the ion trapping that determines the overall pH response. The graphene surface was selectively functionalized with hydroxyl, amine, and carboxyl groups to understand the role and density of the graphene pH-sensitive functional groups. Later, we establish the development of highly pH-sensitive graphene oxide by controlling its defect density. This research opens a new avenue for integrating micro–nano-sized pH sensors based on graphene derivatives into next-generation sensing platforms.
Collapse
Affiliation(s)
- Shayan Angizi
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada; (S.A.); (X.H.); (L.H.); (M.A.A.)
| | - Xianxuan Huang
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada; (S.A.); (X.H.); (L.H.); (M.A.A.)
| | - Lea Hong
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada; (S.A.); (X.H.); (L.H.); (M.A.A.)
| | - Md Ali Akbar
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada; (S.A.); (X.H.); (L.H.); (M.A.A.)
| | - P. Ravi Selvaganapathy
- Department of Mechanical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada;
| | - Peter Kruse
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada; (S.A.); (X.H.); (L.H.); (M.A.A.)
- Correspondence:
| |
Collapse
|
7
|
Gui Y, Liu Z, Ji C, Xu L, Chen X. Adsorption behavior of metal oxides (CuO, NiO, Ag2O) modified GeSe monolayer towards dissolved gases (CO, CH4, C2H2, C2H4) in transformer oil. J IND ENG CHEM 2022. [DOI: 10.1016/j.jiec.2022.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
8
|
Saha D, Angizi S, Darestani-Farahani M, Dalmieda J, Selvaganapathy PR, Kruse P. Tuning the Chemical and Mechanical Properties of Conductive MoS 2 Thin Films by Surface Modification with Aryl Diazonium Salts. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:3666-3675. [PMID: 35298176 PMCID: PMC8969871 DOI: 10.1021/acs.langmuir.1c03061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Molybdenum disulfide (MoS2) is a promising material for applications in sensors, energy storage, energy conversion devices, solar cells, and fuel cells. Because many of those applications require conductive materials, we recently developed a method for preparing a conductive form of MoS2 (c-MoS2) using dilute aqueous hydrogen peroxide in a simple and safe way. Here, we investigate modulating the chemical and mechanical surface properties of c-MoS2 thin films using diazonium chemistry. In addition to a direct passivation strategy of c-MoS2 with diazonium salts for electron-withdrawing groups, we also propose a novel in situ synthetic pathway for modification with electron-donating groups. The obtained results are examined by Raman spectroscopy and X-ray photoelectron spectroscopy. The degree of surface passivation of pristine and functionalized c-MoS2 films was tested by exposing them to aqueous solutions of different metal cations (Fe2+, Zn2+, Cu2+, and Co2+) and detecting the chemiresistive response. While pristine films were found to interact with several of the cations, modified films did not. We propose that a surface charge transfer mechanism is responsible for the chemiresistive response of the pristine films, while both modification routes succeeded at complete surface passivation. Functionalization was also found to lower the coefficient of friction for semiconducting 2H-MoS2, while all conductive materials (modified or not) also had lower coefficients of friction. This opens up a pathway to a palette of dry lubricant materials with improved chemical stability and tunable conductivity. Thus, both in situ and direct diazonium chemistries are powerful tools for tuning chemical and mechanical properties of conductive MoS2 for new devices and lubricants based on conductive MoS2.
Collapse
Affiliation(s)
- Dipankar Saha
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton, Ontario L8S 4M1, Canada
| | - Shayan Angizi
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton, Ontario L8S 4M1, Canada
| | - Maryam Darestani-Farahani
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton, Ontario L8S 4M1, Canada
| | - Johnson Dalmieda
- Department
of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | - Ponnambalam Ravi Selvaganapathy
- Department
of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
- School
of Biomedical Engineering, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Peter Kruse
- Department
of Chemistry and Chemical Biology, McMaster
University, Hamilton, Ontario L8S 4M1, Canada
- E-mail:
| |
Collapse
|
9
|
Towards Integration of Two-Dimensional Hexagonal Boron Nitride (2D h-BN) in Energy Conversion and Storage Devices. ENERGIES 2022. [DOI: 10.3390/en15031162] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
The prominence of two-dimensional hexagonal boron nitride (2D h-BN) nanomaterials in the energy industry has recently grown rapidly due to their broad applications in newly developed energy systems. This was necessitated as a response to the demand for mechanically and chemically stable platforms with superior thermal conductivity for incorporation in next-generation energy devices. Conventionally, the electrical insulation and surface inertness of 2D h-BN limited their large integration in the energy industry. However, progress on surface modification, doping, tailoring the edge chemistry, and hybridization with other nanomaterials paved the way to go beyond those conventional characteristics. The current application range, from various energy conversion methods (e.g., thermoelectrics) to energy storage (e.g., batteries), demonstrates the versatility of 2D h-BN nanomaterials for the future energy industry. In this review, the most recent research breakthroughs on 2D h-BN nanomaterials used in energy-based applications are discussed, and future opportunities and challenges are assessed.
Collapse
|
10
|
Zhang T, Pan W, Zhang Z, Qi N, Chen Z. Theoretical Study of Small Molecules Adsorption on Pristine and Transition Metal Doped GeSe Monolayer for Gas Sensing Application. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:1287-1295. [PMID: 35021624 DOI: 10.1021/acs.langmuir.1c03232] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
By using first-principles calculations, the sensing properties of pristine and transition metal (TM) atoms (Ti, V, and Co) embedded germanium selenide (GeSe) monolayer toward small gas molecules (H2, NH3, CO, O2, SO2, NO, and NO2) were investigated. The adsorption energies, electronic structure, optical properties, and recovery time of the adsorption systems were calculated and analyzed in detail. The results indicate that TM doped GeSe has stronger interaction with gas molecules compared with the pristine GeSe monolayer. Especially for Ti- and V-GeSe monolayer, the absolute value of adsorption energies are up to 2 eV for O2, NO, and NO2. The doping with TM atoms also changes the charge transfer and electronic structures of adsorption systems. Combined with the result of the calculated optical properties and recovery time, it can be concluded that Ti-GeSe monolayer has great potential for NH3 detection, while Co-GeSe monolayer can be very promising SO2 gas sensors.
Collapse
Affiliation(s)
- Tingting Zhang
- Hubei Nuclear Solid Physics Key Laboratory, Department of Physics, Wuhan University, Wuhan 430072, China
| | - Wenfeng Pan
- College of Basic Sciences, Zhengzhou University of Technology, Zhengzhou 450044, China
| | - Ziye Zhang
- Hubei Nuclear Solid Physics Key Laboratory, Department of Physics, Wuhan University, Wuhan 430072, China
| | - Ning Qi
- Hubei Nuclear Solid Physics Key Laboratory, Department of Physics, Wuhan University, Wuhan 430072, China
| | - Zhiquan Chen
- Hubei Nuclear Solid Physics Key Laboratory, Department of Physics, Wuhan University, Wuhan 430072, China
| |
Collapse
|
11
|
Zubiarrain-Laserna A, Angizi S, Akbar MA, Divigalpitiya R, Selvaganapathy PR, Kruse P. Detection of free chlorine in water using graphene-like carbon based chemiresistive sensors. RSC Adv 2022; 12:2485-2496. [PMID: 35425275 PMCID: PMC8979178 DOI: 10.1039/d1ra08264g] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 01/12/2022] [Indexed: 01/02/2023] Open
Abstract
Free chlorine is the most commonly used water disinfectant. Measuring its concentration during and after water treatment is crucial to ensure its effectiveness. However, many of the existing methods do not allow for continuous on-line monitoring. Here we demonstrate a solid state chemiresistive sensor using graphene-like carbon (GLC) that overcomes that issue. GLC films that were either bare or non-covalently functionalized with the redox-active phenyl-capped aniline tetramer (PCAT) were successfully employed to quantify aqueous free chlorine, although functionalized devices showed better performance. The response of the sensors to increasing concentrations of free chlorine followed a Langmuir adsorption isotherm in the two tested ranges: 0.01–0.2 ppm and 0.2–1.4 ppm. The limit of detection was estimated to be 1 ppb, permitting the detection of breaches in chlorine filters. The devices respond to decreasing levels of free chlorine without the need for a reset, allowing for the continuous monitoring of fluctuations in the concentration. The maximum sensor response and saturation concentration were found to depend on the thickness of the GLC film. Hence, the sensitivity and dynamic range of the sensors can be tailored to different applications by adjusting the thickness of the films. Tap water samples from a residential area were tested using these sensors, which showed good agreement with standard colorimetric measurement methods. The devices did not suffer from interferences in the presence of ions commonly found in drinking water. Overall, these sensors are a cost-effective option for the continuous automated monitoring of free chlorine in drinking water. Chemiresistive sensors based on graphene-like carbon films are very stable and sensitive. They can be used for continuous online monitoring of free chlorine.![]()
Collapse
Affiliation(s)
- Ana Zubiarrain-Laserna
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | - Shayan Angizi
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | - Md Ali Akbar
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | | | | | - Peter Kruse
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| |
Collapse
|