1
|
Yokota K, Usuda S, Nishimura T, Takahashi R, Taoka Y, Kobayashi S, Tanaka M, Matsumura K, Yusa SI. Self-Assembly and Drug Encapsulation Properties of Biocompatible Amphiphilic Diblock Copolymers. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2025; 41:765-773. [PMID: 39745176 DOI: 10.1021/acs.langmuir.4c04048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2025]
Abstract
To prepare amphiphilic diblock copolymers (M100Pm), a controlled radical polymerization approach was employed, incorporating hydrophilic poly(2-(methacryloyloxy)ethyl phosphorylcholine) (PMPC) with hydrophobic poly(3-methoxypropyl acrylate) (PMPA). The synthesized diblock copolymers feature a PMPC block with a degree of polymerization (DP) of 100 and a PMPA block with DP (=m) values of 171 and 552. The hydrophilic PMPC block exhibits biocompatibility, such as inhibition of platelet and protein adsorption, because of its hydrophilic pendant zwitterionic phosphorylcholine groups that have the same chemical structure as cell membrane surfaces. The PMPA block exhibits hydrophilicity because of its hydrophilic ether groups; however, it is predominantly hydrophobic. In addition, PMPA exhibits biocompatibility. Because both blocks of M100Pm are biocompatible, M100Pm has potential applications in the biomedical field as an innovative material. Because of the hydrophobicity of the PMPA blocks, which were surrounded by hydrophilic PMPC shells, M100Pm aggregated when dispersed in water. M100P171 and M100P552 formed spherical micelles and vesicles, respectively. As the DP of the PMPA block increased, the aggregate size and number also increased. Doxorubicin was successfully encapsulated within the M100Pm aggregates. Given their biocompatible properties, M100Pm aggregates have potential applications in drug delivery systems.
Collapse
Affiliation(s)
- Kaito Yokota
- Department of Applied Chemistry, Graduate School of Engineering, University of Hyogo, Shosha, Himeji, Hyogo 671-2201, Japan
| | - Sari Usuda
- Department of Applied Chemistry, Graduate School of Engineering, University of Hyogo, Shosha, Himeji, Hyogo 671-2201, Japan
| | - Tomoya Nishimura
- Department of Applied Chemistry, Graduate School of Engineering, University of Hyogo, Shosha, Himeji, Hyogo 671-2201, Japan
| | - Rintaro Takahashi
- Department of Energy Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8603, Japan
| | - Yusuke Taoka
- School of Materials Science, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa 923-1211, Japan
| | - Shingo Kobayashi
- Soft Materials Chemistry, Institute for Materials Chemistry and Engineering, Kyushu University, Build. CE41, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Masaru Tanaka
- Soft Materials Chemistry, Institute for Materials Chemistry and Engineering, Kyushu University, Build. CE41, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Kazuaki Matsumura
- School of Materials Science, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa 923-1211, Japan
| | - Shin-Ichi Yusa
- Department of Applied Chemistry, Graduate School of Engineering, University of Hyogo, Shosha, Himeji, Hyogo 671-2201, Japan
| |
Collapse
|
2
|
Nishimura SN, Kurahashi N, Shiomoto S, Harada Y, Tanaka M. Effects of hydration water on bioresponsiveness of polymer interfaces revealed by analysis of linear and cyclic polymer-grafted substrates. SOFT MATTER 2024. [PMID: 39565239 DOI: 10.1039/d4sm00977k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2024]
Abstract
Given that the hydration water of polymer matrices may differ from that of outermost polymer surfaces, processes at biomaterial-biofluid interfaces and role of hydration water therein cannot be adequately examined using most conventional characterization methods. To bridge this gap, a gold substrate was herein modified with linear and cyclic poly(2-methoxyethyl acrylate) to prepare gl-PMEA and gc-PMEA surfaces, respectively, as models for the outermost surfaces of blood-contacting medical devices. Both surfaces suppressed the adhesion of human platelets but differed in the adhesion behaviors of normal and tumor cells despite having the same areal density of fixed-end units. The surfaces were analyzed using quartz crystal microbalance (QCM), frequency modulation atomic force microscopy (FM-AFM), and X-ray emission spectroscopy (XES) measurements under wet conditions to clarify the relationship between bioresponsivity and hydration water. QCM measurements provided evidence that both grafted-PMEA were hydrated. FM-AFM observations revealed that the swelling layer was thicker for gc-PMEA. To rationalize the differences in the surface hydration states, we performed XES measurements under conditions enabling control over the number of hydration water molecules. In the low-water-content region, hydrogen bonds or interactions between water molecules developed in the vicinity of gl-PMEA but not gc-PMEA. Thus, the initial hydration behavior of the gc-PMEA surface, which promoted intermediate water formation, was different from that of the gl-PMEA surface. The results suggested that the adjustment and optimization of the hydration state of outermost biomaterial surfaces enable the control of bioresponsivity, including the selective isolation of tumor cells.
Collapse
Affiliation(s)
- Shin-Nosuke Nishimura
- Institute for Materials Chemistry and Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
- Department of Molecular Chemistry and Biochemistry, Faculty of Science and Engineering, Doshisha University, 1-3 Tatara Miyakodani, Kyotanabe, Kyoto 610-0394, Japan
| | - Naoya Kurahashi
- Department of Materials Molecular Science, Institute for Molecular Science, 38 Nishigonaka, Myodaijicho, Okazaki, Aichi 444-8585, Japan
- Institute for Solid State Physics, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8581, Japan.
| | - Shohei Shiomoto
- Institute for Materials Chemistry and Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
| | - Yoshihisa Harada
- Institute for Solid State Physics, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8581, Japan.
- Synchrotron Radiation Collaborative Research Organization, The University of Tokyo, 468-1 Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8572, Japan
| | - Masaru Tanaka
- Institute for Materials Chemistry and Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
| |
Collapse
|
3
|
Simple Detection and Culture of Circulating Tumor Cells from Colorectal Cancer Patients Using Poly(2-Methoxyethyl Acrylate)-Coated Plates. Int J Mol Sci 2023; 24:ijms24043949. [PMID: 36835361 PMCID: PMC9959032 DOI: 10.3390/ijms24043949] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 01/15/2023] [Accepted: 01/23/2023] [Indexed: 02/18/2023] Open
Abstract
Here we aimed to establish a simple detection method for detecting circulating tumor cells (CTCs) in the blood sample of colorectal cancer (CRC) patients using poly(2-methoxyethyl acrylate) (PMEA)-coated plates. Adhesion test and spike test using CRC cell lines assured efficacy of PMEA coating. A total of 41 patients with pathological stage II-IV CRC were enrolled between January 2018 and September 2022. Blood samples were concentrated by centrifugation by the OncoQuick tube, and then incubated overnight on PMEA-coated chamber slides. The next day, cell culture and immunocytochemistry with anti-EpCAM antibody were performed. Adhesion tests revealed good attachment of CRCs to PMEA-coated plates. Spike tests indicated that ~75% of CRCs from a 10-mL blood sample were recovered on the slides. By cytological examination, CTCs were identified in 18/41 CRC cases (43.9%). In cell cultures, spheroid-like structures or tumor-cell clusters were found in 18/33 tested cases (54.5%). Overall, CTCs and/or growing circulating tumor cells were found in 23/41 CRC cases (56.0%). History of chemotherapy or radiation was significantly negatively correlated with CTC detection (p = 0.02). In summary, we successfully captured CTCs from CRC patients using the unique biomaterial PMEA. Cultured tumor cells will provide important and timely information regarding the molecular basis of CTCs.
Collapse
|
4
|
Nishida K, Baba K, Murakami D, Tanaka M. Nanoscopic Analyses of Protein Adsorption on Poly(2-methoxyethyl acrylate) Surfaces for Tailoring Cell Adhesiveness. Biomater Sci 2022; 10:2953-2963. [DOI: 10.1039/d2bm00093h] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Regulation of protein adsorption on the surface of biomaterials is important for modulating cell adhesion. Two important proteins in this regard are fibrinogen and fibronectin. Poly(2-methoxyethyl acrylate) (PMEA) and its...
Collapse
|