1
|
Ribaudo JG, He K, Madira S, Young ER, Martin C, Lu T, Sacks JM, Li X. Sutureless vascular anastomotic approaches and their potential impacts. Bioact Mater 2024; 38:73-94. [PMID: 38699240 PMCID: PMC11061647 DOI: 10.1016/j.bioactmat.2024.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 03/25/2024] [Accepted: 04/04/2024] [Indexed: 05/05/2024] Open
Abstract
Sutureless anastomotic devices present several advantages over traditional suture anastomosis, including expanded global access to microvascular surgery, shorter operation and ischemic times, and reduced costs. However, their adaptation for arterial use remains a challenge. This review aims to provide a comprehensive overview of sutureless anastomotic approaches that are either FDA-approved or under investigation. These approaches include extraluminal couplers, intraluminal devices, and methods assisted by lasers or vacuums, with a particular emphasis on tissue adhesives. We analyze these devices for artery compatibility, material composition, potential for intimal damage, risks of thrombosis and restenosis, and complications arising from their deployment and maintenance. Additionally, we discuss the challenges faced in the development and clinical application of sutureless anastomotic techniques. Ideally, a sutureless anastomotic device or technique should eliminate the need for vessel eversion, mitigate thrombosis through either biodegradation or the release of antithrombotic drugs, and be easily deployable for broad use. The transformative potential of sutureless anastomotic approaches in microvascular surgery highlights the necessity for ongoing innovation to expand their applications and maximize their benefits.
Collapse
Affiliation(s)
- Joseph G. Ribaudo
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University in St. Louis, MO, 63110, USA
| | - Kevin He
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University in St. Louis, MO, 63110, USA
| | - Sarah Madira
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University in St. Louis, MO, 63110, USA
| | - Emma R. Young
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University in St. Louis, MO, 63110, USA
| | - Cameron Martin
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University in St. Louis, MO, 63110, USA
| | - Tingying Lu
- Department of Plastic Surgery, Johns Hopkins School of Medicine, Baltimore, MD, 21287, USA
| | - Justin M. Sacks
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University in St. Louis, MO, 63110, USA
| | - Xiaowei Li
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Washington University in St. Louis, MO, 63110, USA
| |
Collapse
|
2
|
Wu J, Lee J, Jung JY, Hwang JH, Kim KS, Shin M, Lee H, Park SH. Less-Suture Vascular Anastomosis: Development of Alternative Protocols with Multifunctional Self-Wrapping, Transparent, Adhesive, and Elastic Biomaterials. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2301098. [PMID: 37196994 DOI: 10.1002/adma.202301098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2023] [Revised: 05/04/2023] [Indexed: 05/19/2023]
Abstract
Blood vessel anastomosis by suture is a life-saving, yet time-consuming and labor-intensive operation. While suture-less alternatives utilizing clips or related devices are developed to address these shortcomings, suture anastomosis is still overwhelmingly used in most cases. In this study, practical "less-suture" strategies are proposed, rather than ideal "suture-less" methods, to reflect real-world clinical situations. In the case of rat artery (d = 0.64 mm) anastomosis, the less-suture anastomosis involves the application of thin, adhesive, transparent, and self-wrapping films to the site. This surprisingly reduces the number of stitches required from ten (without films) to four (with films), saving 27 min of operating time per vessel. Furthermore, the decreased number of stitches largely alleviates fibrosis-mediated wall-thickening. Thus, a less-suture strategy is particularly useful for anastomosis of multiple vessels in emergency conditions and small-diameter vessels.
Collapse
Affiliation(s)
- Jingxian Wu
- Department of Chemistry, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Jaemeun Lee
- R&D Center for Advanced Pharmaceuticals & Evaluation, Korea Institute of Toxicology (KIT), Daejeon, 34114, Republic of Korea
| | - Joo Young Jung
- Orthopaedic Department, Seail Hospital, Busan, 48793, Republic of Korea
| | - Jeong Ho Hwang
- Animal Model Research Group, Korea Institute of Toxicology (KIT), Jeongeup, 56212, Republic of Korea
- Human and Environmental Toxicology, Korea University of Science and Technology (UST), Daejeon, 34113, Republic of Korea
| | - Ki-Suk Kim
- R&D Center for Advanced Pharmaceuticals & Evaluation, Korea Institute of Toxicology (KIT), Daejeon, 34114, Republic of Korea
| | - Mikyung Shin
- Department of Biomedical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Haeshin Lee
- Department of Chemistry, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Sun-Hyun Park
- R&D Center for Advanced Pharmaceuticals & Evaluation, Korea Institute of Toxicology (KIT), Daejeon, 34114, Republic of Korea
| |
Collapse
|
3
|
Scott BB, Randolph MA, Guastaldi FPS, Wu RC, Redmond RW. Light-Activated Vascular Anastomosis. Surg Innov 2022:15533506221104382. [DOI: 10.1177/15533506221104382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Background. There have been few advances in technique since vascular anastomosis was performed with silk suture on a curved needle in 1902. This technique results in disruption of the endothelium with exposed intraluminal suture, both of which may lead to thrombocyte aggregation, intimal hyperplasia, and vascular stenosis. A variety of alternative techniques have been explored, with limited success. Photochemical tissue bonding (PTB) is a light-activated methodology of rapidly cross-linking tissue interfaces at the molecular level. Herein, we describe a new technique for anastomosis of venous interposition graft in an ovine model of femoral artery bypass utilizing PTB. Methods. Polypay specific pathogen free sheep (n = 5; 40-45 kg) underwent femoral artery bypass utilizing saphenous vein. The femoral artery was transected and reversed saphenous vein was implanted as an interposition graft. The proximal anastomosis was created as a vein-over-artery cuff utilizing PTB, and the distal anastomosis was created with standard interrupted 8-0 polypropylene suture. Four weeks post-index operation, femoral angiogram was performed to evaluate patency, tortuosity, and luminal diameter. All bypass grafts were harvested and longitudinal and transverse histological sections from the proximal anastomosis were analyzed. Results. The PTB anastomoses (n = 5) were immediately watertight and patent. All animals survived the 28-day study duration. Angiography revealed patent grafts with no aneurysm or stenosis (n = 5). Histologic examination revealed integration of the venous endothelium with the arterial adventitia. Conclusion. Photochemical tissue bonding creates an immediate strong, watertight vascular anastomosis that can withstand physiologic arterial pressure and remains patent at 28 days without the need for intraluminal suture.
Collapse
Affiliation(s)
- Benjamin B. Scott
- Wellman Center for Photomedicine, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
- Plastic Surgery Research Laboratory, Department of Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| | - Mark A. Randolph
- Plastic Surgery Research Laboratory, Department of Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| | - Fernando P. S. Guastaldi
- Skeletal Biology Research Center, Department of Oral and Maxillofacial Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| | - Ruby C. Wu
- Wellman Center for Photomedicine, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| | - Robert W. Redmond
- Wellman Center for Photomedicine, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
4
|
Detamornrat U, McAlister E, Hutton ARJ, Larrañeta E, Donnelly RF. The Role of 3D Printing Technology in Microengineering of Microneedles. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2106392. [PMID: 35362226 DOI: 10.1002/smll.202106392] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 03/13/2022] [Indexed: 06/14/2023]
Abstract
Microneedles (MNs) are minimally invasive devices, which have gained extensive interest over the past decades in various fields including drug delivery, disease diagnosis, monitoring, and cosmetics. MN geometry and shape are key parameters that dictate performance and therapeutic efficacy, however, traditional fabrication methods, such as molding, may not be able to offer rapid design modifications. In this regard, the fabrication of MNs using 3D printing technology enables the rapid creation of complex MN prototypes with high accuracy and offers customizable MN devices with a desired shape and dimension. Moreover, 3D printing shows great potential in producing advanced transdermal drug delivery systems and medical devices by integrating MNs with a variety of technologies. This review aims to demonstrate the advantages of exploiting 3D printing technology as a new tool to microengineer MNs. Various 3D printing methods are introduced, and representative MNs manufactured by such approaches are highlighted in detail. The development of advanced MN devices is also included. Finally, clinical translation and future perspectives for the development of MNs using 3D printing are discussed.
Collapse
Affiliation(s)
- Usanee Detamornrat
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Emma McAlister
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Aaron R J Hutton
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| |
Collapse
|
5
|
Zhu T, Zhou M, Gao W, Fang D, Liu Z, Wu G, Wan M, Mao C, Shen J. Coronary Stents Decorated by Heparin/NONOate Nanoparticles for Anticoagulant and Endothelialized Effects. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:2901-2910. [PMID: 32114762 DOI: 10.1021/acs.langmuir.0c00112] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In the treatment of coronary artery disease (CAD), the use of stent implantation often leads to clinical complications such as restenosis, delayed endothelial healing, and thrombosis. Here, we develop a double drug sustained-release coating for the stent surface by grafting heparin/NONOate nanoparticles (Hep/NONOates). The Hep/NONOates and surface modification of the stent were characterized by X-ray photoelectron spectroscopy, attenuated total reflection Fourier-transform infrared spectroscopy, static water contact angle, and scanning electron microscopy (SEM), and the release behaviors of the anticoagulant, heparin (Hep) and the bioactive molecule, nitric oxide (NO) were studied. Furthermore, the blood compatibility and cytotoxicity of the modified stent were evaluated by whole blood adhesion and platelet adhesion tests, hemolysis assay, morphological changes of red blood cells, plasma recalcification time assay, in vitro coagulation time tests, and MTT assay. Finally, the results of a rabbit carotid artery stent implantation experiment showed that the double drug sustained-release coating for the stent can accelerate regeneration of endothelial cells and keep good anticoagulant activity. This study can provide new design ideas based on nanotechnology for improving the safety and effectiveness of drug-eluting stents.
Collapse
Affiliation(s)
- Tianyu Zhu
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Min Zhou
- Department of Vascular Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China
| | - Wentao Gao
- Department of Vascular Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China
| | - Dan Fang
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Zhiyong Liu
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Guangyan Wu
- Department of Vascular Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China
| | - Mimi Wan
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Chun Mao
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Jian Shen
- National and Local Joint Engineering Research Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| |
Collapse
|