1
|
Yang C, Wang Q, Chen S, Li J. Ultrathin, Lightweight Materials Enabled Wireless Data and Power Transmission in Chip-Less Flexible Electronics. ACS MATERIALS AU 2025; 5:45-56. [PMID: 39802153 PMCID: PMC11718531 DOI: 10.1021/acsmaterialsau.4c00106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2024] [Revised: 11/13/2024] [Accepted: 11/14/2024] [Indexed: 01/16/2025]
Abstract
The surge of flexible, biointegrated electronics has inspired continued research efforts in designing and developing chip-less and wireless devices as soft and mechanically compliant interfaces to the living systems. In recent years, innovations in materials, devices, and systems have been reported to address challenges surrounding this topic to empower their reliable operation for monitoring physiological signals. This perspective provides a brief overview of recent works reporting various chip-less electronics for sensing and actuation in diverse application scenarios. We summarize wireless signal/data/power transmission strategies, key considerations in materials design and selection, as well as successful demonstrations of sensors and actuators in wearable and implantable forms. The final section provides an outlook to the future direction down the road for performance improvement and optimization. These versatile, inexpensive, and low-power device concepts can serve as alternative strategies to existing digital wireless electronics, which will find broad applications as bidirectional biointerfaces in basic biomedical research and clinical practices.
Collapse
Affiliation(s)
- Chunyu Yang
- Department
of Materials Science and Engineering, The
Ohio State University, Columbus, Ohio 43210, United States
| | - Qi Wang
- Department
of Materials Science and Engineering, The
Ohio State University, Columbus, Ohio 43210, United States
| | - Shulin Chen
- Department
of Materials Science and Engineering, The
Ohio State University, Columbus, Ohio 43210, United States
| | - Jinghua Li
- Department
of Materials Science and Engineering, The
Ohio State University, Columbus, Ohio 43210, United States
- Chronic
Brain Injury Program, The Ohio State University, Columbus, Ohio 43210, United States
| |
Collapse
|
2
|
Meng C, Snizhko DV, Zholudov YT, Zhang W, Guan Y, Tian Y, Xu G. Wireless single-electrode electrochemiluminescence device based on wireless reverse charging or on-the-go USB transmission for multiplex analysis. Chem Commun (Camb) 2024; 60:13546-13549. [PMID: 39474777 DOI: 10.1039/d4cc04873c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2024]
Abstract
A wireless electrochemiluminescence (ECL) device employing the wireless reverse charging function or on-the-go (OTG) USB transmission function of smartphones is designed. It was coupled with a multi-channel single-electrode electrochemical system based on the resistance-induced potential difference for multiple ECL analyses using a smartphone as the detector.
Collapse
Affiliation(s)
- Chengda Meng
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China.
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, China
| | - Dmytro Viktorovych Snizhko
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China.
- Laboratory of Analytical Optochemotronics, Kharkiv National University of Radio Electronics, Kharkiv 61166, Ukraine
| | - Yuriy Tymofiiovych Zholudov
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China.
- Laboratory of Analytical Optochemotronics, Kharkiv National University of Radio Electronics, Kharkiv 61166, Ukraine
| | - Wei Zhang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China.
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, China
| | - Yiran Guan
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China.
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, China
| | - Yu Tian
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China.
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, China
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China.
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
3
|
Tamiya E, Osaki S, Nagai H. Wireless electrochemiluminescent biosensors: Powering innovation with smartphone technology. Biosens Bioelectron 2024; 252:116083. [PMID: 38387231 DOI: 10.1016/j.bios.2024.116083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2023] [Revised: 01/21/2024] [Accepted: 01/26/2024] [Indexed: 02/24/2024]
Abstract
Energy supply and sensor response acquisition can be performed wirelessly, enabling biosensors as Internet of Thing (IoT) tools by linking wireless power supply and electrochemical sensors. Here, we used the electromagnetic induction method to clarify the conditions under which electrochemiluminescence is induced by a simple potential modulation circuit without an integrated circuit on the electrode chip that receives the power. Initially, the potential waveform obtained in a circuit with inductance and capacitance components that resonate with the transmission frequency and a diode for rectification was investigated to clarify the conditions inducing an electrochemiluminescence reaction at the printed electrode. A high-sensitivity complementary metal-oxide semiconductor camera built into the smartphone wirelessly detected the luminescence generated on the electrode chip. The images were quantitatively evaluated using open-source image analysis software which determine the sensitivity of detecting hydrogen peroxide. Glucose oxidase (GOD) encapsulated in a matrix of chitosan polymers and photocrosslinkable polymers was immobilized on a mass-producible and inexpensive printed electrode to maintain high activity. The immobilized membrane suppressed luminescence when immobilized on the working electrode; therefore, the enzyme was immobilized on the counter electrode for glucose measurement over a wide concentration. Thus, luminol electrochemiluminescence was induced on the electrode chip by wireless power supply from a smartphone. Human serum and artificial sweat samples were tested and indicated possibility for actual applications. In this way a fully wireless biosensor was developed with potential as an IoT biosensor.
Collapse
Affiliation(s)
- Eiichi Tamiya
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan; SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki 567-0047, Osaka, Japan.
| | - Shuto Osaki
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
| | - Hidenori Nagai
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
| |
Collapse
|
4
|
Xue Y, Wu F, Zhao X, Ji W, Hou L, Yu P, Mao L. Highly Sensitive Near-Field Electrochemical Sensor for In Vivo Monitoring of Respiratory Patterns. ACS Sens 2024; 9:2149-2155. [PMID: 38579117 DOI: 10.1021/acssensors.4c00261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2024]
Abstract
Real-time tracking of respiratory patterns provides noninvasive and quick access for evaluating pathophysiological conditions yet remains challenging due to limited temporal resolution and poor sensitivity to dig out fingerprints of respiratory waveforms. Here, we report an electrochemical sensor for accurately tracing respiratory patterns of small animal models based on the electrochemical impedance mechanism for wireless coupling of a graphdiyne oxide (GYDO)-modified sensing coil chip and a reader coil chip via near-field magnetic induction. In the electrochemical impedance measurement mode, an alternating current is applied through the reader coil chip to perturb proton transport at the GYDO interface of the sensing coil chip. As demonstrated, a high-frequency perturbing condition significantly reduces the interfacial resistance for proton transport by 5 orders of magnitude under 95% relative humidity (RH) and improves the low-humidity responses with a limit of detection down to 0.2% RH, enabling in vivo accurate profiling of respiratory patterns on epileptic rats. The electrochemical impedance coupling system holds great potential for new wireless bioelectronics.
Collapse
Affiliation(s)
- Yifei Xue
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| | - Fei Wu
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| | - Xudong Zhao
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| | - Wenliang Ji
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| | - Lijuan Hou
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| | - Ping Yu
- Beijing National Laboratory for Molecular Science, Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Lanqun Mao
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| |
Collapse
|
5
|
Thirabowonkitphithan P, Žalnėravičius R, Shafaat A, Jakubauskas D, Neilands J, Laiwattanapaisal W, Ruzgas T. Electrogenicity of microbial biofilms of medically relevant microorganisms: potentiometric, amperometric and wireless detection. Biosens Bioelectron 2024; 246:115892. [PMID: 38056343 DOI: 10.1016/j.bios.2023.115892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 11/27/2023] [Indexed: 12/08/2023]
Abstract
Since the progression of biofilm formation is related to the success of infection treatment, detecting microbial biofilms is of great interest. Biofilms of Gram-positive Staphylococcus aureus and Streptococcus gordonii bacteria, Gram-negative Pseudomonas aeruginosa and Escherichia coli bacteria, and Candida albicans yeast were examined using potentiometric, amperometric, and wireless readout modes in this study. As a biofilm formed, the open circuit potential (OCP) of biofilm hosting electrode (bioanode) became increasingly negative. Depending on the microorganism, the OCP ranged from -70 to -250 mV. The co-culture generated the most negative OCP (-300 mV vs Ag/AgCl), while the single-species biofilm formed by E. coli developed the least negative (-70 mV). The OCP of a fungal biofilm formed by C. albicans was -100 mV. The difference in electrode currents generated by biofilms was more pronounced. The current density of the S. aureus biofilm was 0.9‧10-7 A cm-2, while the value of the P. aeruginosa biofilm was 1.3‧10-6 A cm-2. Importantly, a biofilm formed by a co-culture of S. aureus and P. aeruginosa had a slightly higher negative OCP value and current density than the most electrogenic P. aeruginosa single-species biofilm. We present evidence that bacteria can share redox mediators found in multi-species biofilms. This synergy, enabling higher current and OCP values of multi-species biofilm hosting electrodes, could be beneficial for electrochemical detection of infectious biofilms in clinics. We demonstrate that the electrogenic biofilm can provide basis to construct novel wireless, chip-free, and battery-free biofilm detection method.
Collapse
Affiliation(s)
- Pannawich Thirabowonkitphithan
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 205 06, Malmö, Sweden; Biofilms - Research Center for Biointerfaces, Malmö University, 205 06, Malmö, Sweden; Graduate Program in Clinical Biochemistry and Molecular Medicine, Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand
| | - Rokas Žalnėravičius
- Center for Physical Sciences and Technology, Department of Electrochemical Material Science, Sauletekio av. 3, LT-10257, Vilnius, Lithuania; Institute of Biochemistry, Life Sciences Centre, Vilnius University, Sauletekio av. 7, LT-10257, Vilnius, Lithuania.
| | - Atefeh Shafaat
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 205 06, Malmö, Sweden; Biofilms - Research Center for Biointerfaces, Malmö University, 205 06, Malmö, Sweden
| | - Dainius Jakubauskas
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 205 06, Malmö, Sweden; Biofilms - Research Center for Biointerfaces, Malmö University, 205 06, Malmö, Sweden
| | - Jessica Neilands
- Section for Oral Biology and Pathology, Faculty of Odontology, Malmö University, 205 06, Malmö, Sweden
| | - Wanida Laiwattanapaisal
- Centre of Excellence for Biosensors and Bioengineering (CEBB), Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand; Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand.
| | - Tautgirdas Ruzgas
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 205 06, Malmö, Sweden; Biofilms - Research Center for Biointerfaces, Malmö University, 205 06, Malmö, Sweden
| |
Collapse
|
6
|
Khan MRR. Development of a Battery-Free, Chipless, and Highly Sensitive Radio Frequency Glucose Biosensor. MICROMACHINES 2024; 15:272. [PMID: 38399000 PMCID: PMC10891716 DOI: 10.3390/mi15020272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/09/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024]
Abstract
In our study, we designed and developed a glucose biosensor that operates without a battery or chip. This biosensor utilizes the principles of radio frequency (RF) to operate. For the construction of a glucose-sensitive interdigitated capacitor (IDC), a famous glucose-sensitive substance called phenylboronic acid (PBA) is combined with a polyvinyl chloride (PVC) and n,n-dimethylacetamide (DMAC) solution. According to the theory of radio frequency sensing, the resonance frequency shifts whenever there is a change in the capacitance of the glucose-sensitive IDC. This change is caused by the fluctuations in glucose concentrations. As far as we are aware, this is the first glucose sensor that employs the RF principle to detect changes in glucose solution concentrations using PBA as the principal glucose-sensitive material. The sensor can detect glucose levels with remarkable sensitivity, around 40.89 kHz/decade, and a broad dynamic range covering 10 μM to 1 M. Additionally, the designed biosensor has excellent linearity performance, with a value of around 0.988. The proposed glucose biosensor has several benefits: lightweight, inexpensive, easy to build, and an acceptable selectivity response. Our study concludes by comparing the proposed RF sensor's effectiveness to that of existing glucose sensors, which it outperforms.
Collapse
Affiliation(s)
- Md Rajibur Rahaman Khan
- Research Institute of Engineering and Technology, Hanyang University, Ansan 15588, Republic of Korea
| |
Collapse
|
7
|
Ratautė K, Ratautas D. A Review from a Clinical Perspective: Recent Advances in Biosensors for the Detection of L-Amino Acids. BIOSENSORS 2023; 14:5. [PMID: 38248382 PMCID: PMC10813600 DOI: 10.3390/bios14010005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 12/14/2023] [Accepted: 12/19/2023] [Indexed: 01/23/2024]
Abstract
The field of biosensors is filled with reports and designs of various sensors, with the vast majority focusing on glucose sensing. However, in addition to glucose, there are many other important analytes that are worth investigating as well. In particular, L-amino acids appear as important diagnostic markers for a number of conditions. However, the progress in L-amino acid detection and the development of biosensors for L-amino acids are still somewhat insufficient. In recent years, the need to determine L-amino acids from clinical samples has risen. More clinical data appear to demonstrate that abnormal concentrations of L-amino acids are related to various clinical conditions such as inherited metabolic disorders, dyslipidemia, type 2 diabetes, muscle damage, etc. However, to this day, the diagnostic potential of L-amino acids is not yet fully established. Most likely, this is because of the difficulties in measuring L-amino acids, especially in human blood. In this review article, we extensively investigate the 'overlooked' L-amino acids. We review typical levels of amino acids present in human blood and broadly survey the importance of L-amino acids in most common conditions which can be monitored or diagnosed from changes in L-amino acids present in human blood. We also provide an overview of recent biosensors for L-amino acid monitoring and their advantages and disadvantages, with some other alternative methods for L-amino acid quantification, and finally we outline future perspectives related to the development of biosensing devices for L-amino acid monitoring.
Collapse
Affiliation(s)
- Kristina Ratautė
- Faculty of Medicine, Vilnius University, M. K. Čiurlionio Str. 21, LT-03101 Vilnius, Lithuania
| | - Dalius Ratautas
- Life Science Center, Vilnius University, Saulėtekio al. 7, LT-10257 Vilnius, Lithuania
| |
Collapse
|
8
|
Shafaat A, Gonzalez-Martinez JF, Silva WO, Lesch A, Nagar B, Lopes da Silva Z, Neilands J, Sotres J, Björklund S, Girault H, Ruzgas T. A Rapidly Responsive Sensor for Wireless Detection of Early and Mature Microbial Biofilms. Angew Chem Int Ed Engl 2023; 62:e202308181. [PMID: 37490019 DOI: 10.1002/anie.202308181] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 07/19/2023] [Accepted: 07/24/2023] [Indexed: 07/26/2023]
Abstract
Biofilm-associated infections, which are able to resist antibiotics, pose a significant challenge in clinical treatments. Such infections have been linked to various medical conditions, including chronic wounds and implant-associated infections, making them a major public-health concern. Early-detection of biofilm formation offers significant advantages in mitigating adverse effects caused by biofilms. In this work, we aim to explore the feasibility of employing a novel wireless sensor for tracking both early-stage and matured-biofilms formed by the medically relevant bacteria Staphylococcus aureus and Pseudomonas aeruginosa. The sensor utilizes electrochemical reduction of an AgCl layer bridging two silver legs made by inkjet-printing, forming a part of near-field-communication tag antenna. The antenna is interfaced with a carbon cloth designed to promote the growth of microorganisms, thereby serving as an electron source for reduction of the resistive AgCl into a highly-conductive Ag bridge. The AgCl-Ag transformation significantly alters the impedance of the antenna, facilitating wireless identification of an endpoint caused by microbial growth. To the best of our knowledge, this study for the first time presents the evidence showcasing that electrons released through the actions of bacteria can be harnessed to convert AgCl to Ag, thus enabling the wireless, battery-less, and chip-less early-detection of biofilm formation.
Collapse
Affiliation(s)
- Atefeh Shafaat
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 20506, Malmö, Sweden
- Biofilms - Research Center for Biointerfaces, Malmö University, 20506, Malmö, Sweden
| | | | - Wanderson O Silva
- Institute of Systems Engineering, HES-SO Valais-Wallis, 1950, Sion, Switzerland
| | - Andreas Lesch
- Department of Industrial Chemistry "Toso Montanari", University of Bologna, Viale del Risorgimento 4, 40136, Bologna, Italy
| | - Bhawna Nagar
- Laboratory of Physical and Analytical Electrochemistry, École Polytechnique Fédérale de Lausanne (EPFL) Valais Wallis, 1950, Sion, Switzerland
| | - Zita Lopes da Silva
- Department of Oral Biology, Faculty of Odontology, Malmö University, 20506, Malmö, Sweden
| | - Jessica Neilands
- Department of Oral Biology, Faculty of Odontology, Malmö University, 20506, Malmö, Sweden
| | - Javier Sotres
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 20506, Malmö, Sweden
- Biofilms - Research Center for Biointerfaces, Malmö University, 20506, Malmö, Sweden
| | - Sebastian Björklund
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 20506, Malmö, Sweden
- Biofilms - Research Center for Biointerfaces, Malmö University, 20506, Malmö, Sweden
| | - Hubert Girault
- Laboratory of Physical and Analytical Electrochemistry, École Polytechnique Fédérale de Lausanne (EPFL) Valais Wallis, 1950, Sion, Switzerland
| | - Tautgirdas Ruzgas
- Department of Biomedical Science, Faculty of Health and Society, Malmö University, 20506, Malmö, Sweden
- Biofilms - Research Center for Biointerfaces, Malmö University, 20506, Malmö, Sweden
| |
Collapse
|
9
|
Lazaro A, Villarino R, Lazaro M, Canellas N, Prieto-Simon B, Girbau D. Recent Advances in Batteryless NFC Sensors for Chemical Sensing and Biosensing. BIOSENSORS 2023; 13:775. [PMID: 37622861 PMCID: PMC10452174 DOI: 10.3390/bios13080775] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 07/28/2023] [Accepted: 07/29/2023] [Indexed: 08/26/2023]
Abstract
This article reviews the recent advances in the field of batteryless near-field communication (NFC) sensors for chemical sensing and biosensing. The commercial availability of low-cost commercial NFC integrated circuits (ICs) and their massive integration in smartphones, used as readers and cloud interfaces, have aroused great interest in new batteryless NFC sensors. The fact that coil antennas are not importantly affected by the body compared with other wireless sensors based on far-field communications makes this technology suitable for future wearable point-of-care testing (PoCT) devices. This review first compares energy harvesting based on NFC to other energy-harvesting technologies. Next, some practical recommendations for designing and tuning NFC-based tags are described. Power transfer is key because in most cases, the energy harvested has to be stable for several seconds and not contaminated by undesired signals. For this reason, the effect of the dimensions of the coils and the conductivity on the wireless power transfer is thoroughly discussed. In the last part of the review, the state of the art in NFC-based chemical and biosensors is presented. NFC-based tags (or sensor tags) are mainly based on commercial or custom NFC ICs, which are used to harvest the energy from the RF field generated by the smartphone to power the electronics. Low-consumption colorimeters and potentiostats can be integrated into these NFC tags, opening the door to the integration of chemical sensors and biosensors, which can be harvested and read from a smartphone. The smartphone is also used to upload the acquired information to the cloud to facilitate the internet of medical things (IoMT) paradigm. Finally, several chipless sensors recently proposed in the literature as a low-cost alternative for chemical applications are discussed.
Collapse
Affiliation(s)
- Antonio Lazaro
- Department of Electronics, Electrics and Automatic Control Engineering, Rovira i Virgili University, 43007 Tarragona, Spain; (R.V.); (M.L.); (N.C.); (B.P.-S.); (D.G.)
| | - Ramon Villarino
- Department of Electronics, Electrics and Automatic Control Engineering, Rovira i Virgili University, 43007 Tarragona, Spain; (R.V.); (M.L.); (N.C.); (B.P.-S.); (D.G.)
| | - Marc Lazaro
- Department of Electronics, Electrics and Automatic Control Engineering, Rovira i Virgili University, 43007 Tarragona, Spain; (R.V.); (M.L.); (N.C.); (B.P.-S.); (D.G.)
| | - Nicolau Canellas
- Department of Electronics, Electrics and Automatic Control Engineering, Rovira i Virgili University, 43007 Tarragona, Spain; (R.V.); (M.L.); (N.C.); (B.P.-S.); (D.G.)
| | - Beatriz Prieto-Simon
- Department of Electronics, Electrics and Automatic Control Engineering, Rovira i Virgili University, 43007 Tarragona, Spain; (R.V.); (M.L.); (N.C.); (B.P.-S.); (D.G.)
- Catalan Institution for Research and Advanced Studies (ICREA), Pg. Lluís Companys 23, 08010 Barcelona, Spain
| | - David Girbau
- Department of Electronics, Electrics and Automatic Control Engineering, Rovira i Virgili University, 43007 Tarragona, Spain; (R.V.); (M.L.); (N.C.); (B.P.-S.); (D.G.)
| |
Collapse
|
10
|
Radzevičiūtė-Valčiukė E, Gečaitė J, Želvys A, Zinkevičienė A, Žalnėravičius R, Malyško-Ptašinskė V, Nemeikaitė-Čenienė A, Kašėta V, German N, Novickij J, Ramanavičienė A, Kulbacka J, Novickij V. Improving NonViral Gene Delivery Using MHz Bursts of Nanosecond Pulses and Gold Nanoparticles for Electric Field Amplification. Pharmaceutics 2023; 15:1178. [PMID: 37111663 PMCID: PMC10146442 DOI: 10.3390/pharmaceutics15041178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 03/27/2023] [Accepted: 04/05/2023] [Indexed: 04/29/2023] Open
Abstract
Gene delivery by the pulsed electric field is a promising alternative technology for nonviral transfection; however, the application of short pulses (i.e., nanosecond) is extremely limited. In this work, we aimed to show the capability to improve gene delivery using MHz frequency bursts of nanosecond pulses and characterize the potential use of gold nanoparticles (AuNPs: 9, 13, 14, and 22 nm) in this context. We have used bursts of MHz pulses 3/5/7 kV/cm × 300 ns × 100 and compared the efficacy of the parametric protocols to conventional microsecond protocols (100 µs × 8, 1 Hz) separately and in combination with nanoparticles. Furthermore, the effects of pulses and AuNPs on the generation of reactive oxygen species (ROS) were analyzed. It was shown that gene delivery using microsecond protocols could be significantly improved with AuNPs; however, the efficacy is strongly dependent on the surface charge of AuNPs and their size. The capability of local field amplification using AuNPs was also confirmed by finite element method simulation. Finally, it was shown that AuNPs are not effective with nanosecond protocols. However, MHz protocols are still competitive in the context of gene delivery, resulting in low ROS generation, preserved viability, and easier procedure to trigger comparable efficacy.
Collapse
Affiliation(s)
- Eivina Radzevičiūtė-Valčiukė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
- Faculty of Electronics, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania; (V.M.-P.)
| | - Jovita Gečaitė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
| | - Augustinas Želvys
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
| | - Auksė Zinkevičienė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
| | - Rokas Žalnėravičius
- State Research Institute Center for Physical Science and Technology, 02300 Vilnius, Lithuania;
| | | | - Aušra Nemeikaitė-Čenienė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
| | - Vytautas Kašėta
- Department of Biomodels, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania
| | - Natalija German
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
| | - Jurij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania; (V.M.-P.)
| | - Almira Ramanavičienė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
| | - Julita Kulbacka
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
- Department of Molecular and Cellular Biology, Faculty of Pharmacy, Wroclaw Medical University, 50-367 Wroclaw, Poland
| | - Vitalij Novickij
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (E.R.-V.); (J.G.); (A.Ž.); (A.Z.)
- Faculty of Electronics, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania; (V.M.-P.)
| |
Collapse
|
11
|
Miškinis J, Ramonas E, Gurevičienė V, Razumienė J, Dagys M, Ratautas D. Capacitance-Based Biosensor for the Measurement of Total Loss of L-Amino Acids in Human Serum during Hemodialysis. ACS Sens 2022; 7:3352-3359. [PMID: 36268654 PMCID: PMC9706805 DOI: 10.1021/acssensors.2c01342] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
In this paper, we present a biosensor based on a gold nanoparticle (AuNP)-modified Pt electrode with an adjusted membrane containing cross-linked L-amino acid oxidase for the detection and quantification of total L-amino acids. The designed biosensor was tested and characterized using the capacitance-based principle, capacitance measurements after electrode polarization, disconnection from the circuit, and addition of the respective amount of the analyte. The method was implemented using the capacitive and catalytic properties of the Pt/AuNP electrode; nanostructures were able to store electric charge while at the same time catalyzing the oxidation of the redox reaction intermediate H2O2. In this way, the Pt/AuNP layer was charged after the addition of analytes, allowing for much more accurate measurements for samples with low amino acid concentrations. The combined biosensor electrode with the capacitance-based measurement method resulted in high sensitivity and a low limit of detection (LOD) for hydrogen peroxide (4.15 μC/μM and 0.86 μM, respectively) and high sensitivity, a low LOD, and a wide linear range for L-amino acids (0.73 μC/μM, 5.5 μM and 25-1500 μM, respectively). The designed biosensor was applied to measure the relative loss of amino acids in patients undergoing renal replacement therapy by analyzing amino acid levels in diluted serum samples before and after entering/leaving the hemodialysis apparatus. In general, the designed biosensor in conjunction with the proposed capacitance-based method was clinically tested and could also be applied for the detection of other analytes using analyte-specific oxidases.
Collapse
|