1
|
Wang G, Huang L. Sensitivity enhancement of a silver based surface plasmon resonance sensor via an optimizing graphene-dielectric composite structure. APPLIED OPTICS 2022; 61:683-690. [PMID: 35200772 DOI: 10.1364/ao.446579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 12/21/2021] [Indexed: 06/14/2023]
Abstract
A silver based surface plasmon resonance (SPR) sensor with dielectric-graphene composite film is presented. The influences of the dielectric layer and graphene on sensitivity and other sensing properties are theoretically calculated and then comprehensively discussed. The refractive index sensitivities for composite silver film based SPR sensors with graphene and dielectric layers could be increased by 29% and 288% more than that of monolayer silver film based SPR sensors, respectively. Further, the sensitivity could be enhanced by 202% when combining the graphene and dielectric layers together. Considering the high adsorptive capacity of graphene for biochemical molecules, the composite silver film with both a dielectric layer and graphene would have great potential application in biochemical sensing fields. Further, bovine serum albumin protein was successfully used to verify the biochemical sensing ability of the proposed SPR sensor. The shift of resonance angle is nearly 3.1 fold that of monolayer silver based SPR sensors.
Collapse
|
2
|
Liu L, Han C, Jiang M, Zhang T, Kang Q, Wang X, Wang P, Zhou F. Rapid and regenerable surface plasmon resonance determinations of biomarker concentration and biomolecular interaction based on tris-nitrilotriacetic acid chips. Anal Chim Acta 2021; 1170:338625. [PMID: 34090589 DOI: 10.1016/j.aca.2021.338625] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 05/01/2021] [Accepted: 05/04/2021] [Indexed: 12/22/2022]
Abstract
The tris-nitrilotriacetic acid (tris-NTA) chip has been used for surface plasmon resonance (SPR) kinetic studies involving histidine (His)-tagged proteins. However, its full potential, especially for analyte quantification in complex biological media, has not been realized due to a lack of systematic studies on the factors governing ligand immobilization, surface regeneration, and data analysis. We demonstrate that the tris-NTA chip not only retains His-tagged proteins more strongly than its mono-NTA counterpart, but also orients them more uniformly than protein molecules coupled to carboxymethylated dextran films. We accurately and rapidly quantified immunoglobulin (IgG) molecules in sera by using the initial association phase of their conjugation with His-tagged protein G densely immobilized onto the tris-NTA chip, and established criteria for selecting the optimal time for constructing the calibration curve. The method is highly reproducible (less than 2% RSD) and three orders of magnitude more sensitive than immunoturbidimetry. In addition, we found that the amount of His-protein immobilized is highly dependent on the protein isoelectric point (pI). Reliable kinetic data in a multi-channel SPR instrument can also be rapidly obtained by using a low density of immobilized His-tagged protein. The experimental parameters and procedures outlined in this study help expand the range of SPR applications involving His-tagged proteins.
Collapse
Affiliation(s)
- Luyao Liu
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Chaowei Han
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Meng Jiang
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Tiantian Zhang
- University Hospital, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Qing Kang
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Xiaoying Wang
- State Key Laboratory of Biobased Materials and Green Papermaking, Qilu University of Technology, Jinan, Shandong, 250353, PR China
| | - Pengcheng Wang
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China.
| | - Feimeng Zhou
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China.
| |
Collapse
|
3
|
Harpaz D, Koh B, Seet RC, Abdulhalim I, Tok AI. Functionalized silicon dioxide self-referenced plasmonic chip as point-of-care biosensor for stroke biomarkers NT-proBNP and S100β. Talanta 2020; 212:120792. [DOI: 10.1016/j.talanta.2020.120792] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 01/13/2020] [Accepted: 01/28/2020] [Indexed: 01/08/2023]
|
4
|
Harpaz D, Koh B, Marks RS, Seet RCS, Abdulhalim I, Tok AIY. Point-of-Care Surface Plasmon Resonance Biosensor for Stroke Biomarkers NT-proBNP and S100β Using a Functionalized Gold Chip with Specific Antibody. SENSORS 2019; 19:s19112533. [PMID: 31163612 PMCID: PMC6603756 DOI: 10.3390/s19112533] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Revised: 05/31/2019] [Accepted: 05/31/2019] [Indexed: 12/22/2022]
Abstract
Surface-plasmon-resonance (SPR) is a quantum-electromagnetic phenomenon arising from the interaction of light with free electrons at a metal-dielectric interface. At a specific angle/wavelength of light, the photon's energy is transferred to excite the oscillation of the free electrons on the surface. A change in the refractive-index (RI) may occur, which is influenced by the analyte concentration in the medium in close contact with the metal surface. SPR has been widely used for the detection of gaseous, liquid, or solid samples. In this study, a functionalized specific SPR chip was designed and used in a novel point-of-care SPR module (PhotonicSys SPR H5) for the detection of the stroke biomarkers NT-proBNP and S100β. These biomarkers have proven to be good for stroke diagnosis, with sensitivity and specificity of >85%. Specific detection was done by binding a biomolecular-recognizing antibody onto the Au SPR-chip. Detection was tested in water and plasma samples. NT-proBNP and S100β were detected in a range of concentrations for stroke, from 0.1 ng/mL to 10 ng/mL. The RI of the blank plasma samples was 1.362412, and the lowest concentration tested for both biomarkers showed a prominent shift in the RI signal (0.25 ng/mL NT-proBNP (1.364215) and S100β (1.364024)). The sensor demonstrated a clinically relevant limit-of-detection of less than ng/mL.
Collapse
Affiliation(s)
- Dorin Harpaz
- School of Material Science & Engineering, Nanyang Technology University, 50 Nanyang Avenue, Singapore 639798, Singapore.
- Department of Biotechnology Engineering, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel.
- Institute for Sports Research (ISR), Nanyang Technology University and Loughborough University, Nanyang Avenue, Singapore 639798, Singapore.
| | - Brescia Koh
- School of Material Science & Engineering, Nanyang Technology University, 50 Nanyang Avenue, Singapore 639798, Singapore.
| | - Robert S Marks
- Department of Biotechnology Engineering, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel.
- The National Institute for Biotechnology in the Negev, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel.
- The Ilse Katz Centre for Meso and Nanoscale Science and Technology, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel.
| | - Raymond C S Seet
- Division of Neurology, Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Dr, Singapore 117597, Singapore.
| | - Ibrahim Abdulhalim
- School of Material Science & Engineering, Nanyang Technology University, 50 Nanyang Avenue, Singapore 639798, Singapore.
- The Ilse Katz Centre for Meso and Nanoscale Science and Technology, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel.
- Department of Electro optics and Photonics Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105, Israel.
| | - Alfred I Y Tok
- School of Material Science & Engineering, Nanyang Technology University, 50 Nanyang Avenue, Singapore 639798, Singapore.
- Institute for Sports Research (ISR), Nanyang Technology University and Loughborough University, Nanyang Avenue, Singapore 639798, Singapore.
| |
Collapse
|
5
|
A Sensitive and Stable Surface Plasmon Resonance Sensor Based on Monolayer Protected Silver Film. SENSORS 2017; 17:s17122777. [PMID: 29189753 PMCID: PMC5751622 DOI: 10.3390/s17122777] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Revised: 11/08/2017] [Accepted: 11/14/2017] [Indexed: 12/21/2022]
Abstract
In this paper, we present a stable silver-based surface plasmon resonance (SPR) sensor using a self-assembled monolayer (SAM) as a protection layer and investigated its efficiency in water and 0.01 M phosphate buffered saline (PBS). By simulation, silver-based SPR sensor has a better performance in field enhancement and penetration depth than that of a gold-based SPR sensor, which are 5 and 1.4 times, respectively. To overcome the instability of the bare silver film and investigate the efficiency of the protected layer, the SAM of 11-mercapto-1-undecanol (MUD) was used as a protection layer. Stability experiment results show that the protected silver film exhibited excellent stability either in pure water or 0.01 M PBS buffer. The sensitivity of the silver-based SPR sensor was calculated to be 127.26 deg/RIU (refractive index unit), measured with different concentrations of NaCl solutions. Further, a very high refractive resolution for the silver-based SPR sensor was found to be 2.207 × 10−7 RIU, which reaches the theoretical limit in the wavelength of 632.8 nm for a SPR sensor reported in the literature. Using a mixed SAM of 16-mercaptohexadecanoic acid (MHDA) and a MUD layer with a ratio of 1:10, this immunosensor for the rabbit immunoglobulin G (IgG) molecule with a limit of detection as low as 22.516 ng/mL was achieved.
Collapse
|
6
|
Guselnikova O, Postnikov P, Elashnikov R, Trusova M, Kalachyova Y, Libansky M, Barek J, Kolska Z, Švorčík V, Lyutakov O. Surface modification of Au and Ag plasmonic thin films via diazonium chemistry: Evaluation of structure and properties. Colloids Surf A Physicochem Eng Asp 2017. [DOI: 10.1016/j.colsurfa.2016.12.040] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
7
|
Yang J, Moraillon A, Siriwardena A, Boukherroub R, Ozanam F, Gouget-Laemmel AC, Szunerits S. Carbohydrate Microarray for the Detection of Glycan–Protein Interactions Using Metal-Enhanced Fluorescence. Anal Chem 2015; 87:3721-8. [DOI: 10.1021/ac504262b] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Jie Yang
- Physique
de la Matière Condensée, Ecole Polytechnique-CNRS, 91128 Palaiseau, France
| | - Anne Moraillon
- Physique
de la Matière Condensée, Ecole Polytechnique-CNRS, 91128 Palaiseau, France
| | - Aloysius Siriwardena
- Laboratoire
de Glycochimie des Antimicrobiens et des Agroressources (LG2A), (FRE
3517-CNRS), Université de Picardie Jules Verne, 33 Rue St
Leu, 80039 Amiens, France
| | - Rabah Boukherroub
- Institut
d’Electronique, de Microélectronique et de Nanotechnologie
(IEMN, CNRS-8520), Université Lille 1, Cité Scientifique,
Avenue Poincaré B.P. 60069, 59652 Villeneuve d’Ascq, France
| | - François Ozanam
- Physique
de la Matière Condensée, Ecole Polytechnique-CNRS, 91128 Palaiseau, France
| | | | - Sabine Szunerits
- Institut
d’Electronique, de Microélectronique et de Nanotechnologie
(IEMN, CNRS-8520), Université Lille 1, Cité Scientifique,
Avenue Poincaré B.P. 60069, 59652 Villeneuve d’Ascq, France
| |
Collapse
|
8
|
Subramanian P, Lesniewski A, Kaminska I, Vlandas A, Vasilescu A, Niedziolka-Jonsson J, Pichonat E, Happy H, Boukherroub R, Szunerits S. Lysozyme detection on aptamer functionalized graphene-coated SPR interfaces. Biosens Bioelectron 2013; 50:239-43. [PMID: 23871871 DOI: 10.1016/j.bios.2013.06.026] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2013] [Revised: 06/07/2013] [Accepted: 06/10/2013] [Indexed: 12/18/2022]
Abstract
The paper reports on a surface plasmon resonance (SPR)-based approach for the sensitive and selective detection of lysozyme. The SPR sensor consists of a 50 nm gold film coated with a thin film of reduced graphene oxide (rGO) functionalized with anti-lysozyme DNA aptamer. The SPR chip coating with rGO matrix was achieved through electrophoretic deposition of graphene oxide (GO) at 150 V. Electrophoretic deposition resulted in partial reduction of GO to rGO with a thickness depending on the deposition time. For very short time pulses of 20 s, the resulting rGO film had a thickness of several nanometers and was appropriate for SPR sensing. The utility of the graphene-based SPR sensor for the selective and sensitive detection of proteins was demonstrated using lysozyme as model protein. Functionalization of rGO matrix with anti-lysozyme DNA aptamer through π-stacking interactions allowed selective SPR detection of lysozyme. The graphene-based SPR biosensor provides a means for the label-free, concentration-dependent and selective detection of lysozymes with a detection limit of 0.5 nM.
Collapse
Affiliation(s)
- Palaniappan Subramanian
- Institut de Recherche Interdisciplinaire (IRI), CNRS USR 3078, Université Lille1, Parc de la Haute Borne, 50 avenue de Halley, BP 70478, 59658 Villeneuve d'Ascq, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Szunerits S, Maalouli N, Wijaya E, Vilcot JP, Boukherroub R. Recent advances in the development of graphene-based surface plasmon resonance (SPR) interfaces. Anal Bioanal Chem 2013; 405:1435-43. [DOI: 10.1007/s00216-012-6624-0] [Citation(s) in RCA: 166] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2012] [Revised: 11/20/2012] [Accepted: 11/30/2012] [Indexed: 11/28/2022]
|
10
|
Ke L, Lai SC, Liu H, Peh CKN, Wang B, Teng JH. Ultrasmooth silver thin film on PEDOT:PSS nucleation layer for extended surface plasmon propagation. ACS APPLIED MATERIALS & INTERFACES 2012; 4:1247-1253. [PMID: 22339782 DOI: 10.1021/am201391f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Poly(3,4-ethylene dioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) layers are used as the nucleation (seed) layer to reduce surface roughness of the overlying silver (Ag). The technique leads to ultrasmooth Ag thin films with a minimum surface roughness of 0.8 nm. The mechanism contributing to the improvement is explained on the basis of better wetting of Ag on PEDOT:PSS, and properties of the nucleation layer on the aspects of surface energy, surface adhesive force, and surface morphology influencing Ag wetting and growth pattern are being discussed. The surface plasmon resonance (SPR) shows significant improvement, in terms of the Figure of Merits (FOM), as the surface roughness on Ag films is reduced. A lower light scattering and longer plasmon propagation of maximum 15.3 μm are also realized on a smoother Ag surface. The results indicate great potential on the application of combined PEDOT:PSS/Ag structure as an effective and economically feasible design solution for plasmonic and optical metamaterials devices.
Collapse
Affiliation(s)
- L Ke
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research (A*STAR), 3 Research Link, Singapore 117602.
| | | | | | | | | | | |
Collapse
|
11
|
Kaur K, Forrest JA. Influence of particle size on the binding activity of proteins adsorbed onto gold nanoparticles. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2012; 28:2736-44. [PMID: 22132998 DOI: 10.1021/la203528u] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We used optical extinction spectroscopy to study the structure of proteins adsorbed onto gold nanoparticles of sizes 5-60 nm and their resulting biological binding activity. For these studies, proteins differing in size and shape, with well-characterized and specific interactions-rabbit immunoglobulin G (IgG), goat anti-rabbit IgG (anti-IgG), Staphylococcal protein A, streptavidin, and biotin-were used as model systems. Protein interaction with gold nanoparticles was probed by optical extinction measurements of localized surface plasmon resonance (LSPR) of the gold nanoparticles. Binding of the ligands in solution to protein molecules already immobilized on the surface of gold causes a small but detectable shift in the LSPR peak of the gold nanoparticles. This shift can be used to probe the binding activity of the adsorbed protein. Within the context of Mie theory calculations, the thickness of the adsorbed protein layer as well as its apparent refractive index is shown to depend on the size of the gold nanoparticle. The results suggest that proteins can adopt different orientations that depend on the size of the gold nanospheres. These different orientations, in turn, can result in different levels of biological activity. For example, we find that IgG adsorbed on spheres with diameter ≥20 nm does not bind to protein A. This study illustrates the principle that the size of nanoparticles can strongly influence the binding activity of adsorbed proteins. In addition to the importance of this in cases of direct exposure of proteins to nanoparticles, the results have implications for proteins adsorbed to materials with nanometer scale surface roughness.
Collapse
Affiliation(s)
- Kanwarjeet Kaur
- Department of Physics and Astronomy, Guelph-Waterloo Physics Institute, University of Waterloo, 200 University Avenue W, Waterloo, Ontario N2L 3G1, Canada
| | | |
Collapse
|
12
|
D’Agata R, Spoto G. Surface Plasmon Resonance-Based Methods. DETECTION OF NON-AMPLIFIED GENOMIC DNA 2012. [DOI: 10.1007/978-94-007-1226-3_9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
13
|
Manickam G, Gandhiraman R, Vijayaraghavan RK, Kerr L, Doyle C, Williams DE, Daniels S. Protection and functionalisation of silver as an optical sensing platform for highly sensitive SPR based analysis. Analyst 2012; 137:5265-71. [DOI: 10.1039/c2an35826c] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
14
|
Gandhiraman RP, Le NCH, Dixit CK, Volcke C, Doyle C, Gubala V, Uppal S, Monaghan R, James B, O'Kennedy R, Daniels S, Williams DE. Multi-layered plasma-polymerized chips for SPR-based detection. ACS APPLIED MATERIALS & INTERFACES 2011; 3:4640-4648. [PMID: 22029622 DOI: 10.1021/am201061k] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The surface functionalization of a noble metal is crucial in a surface plasmon resonance-based biomolecular detection system because the interfacial coating must retain the activity of immobilized biomolecules while enhancing the optimal loading. We present here a one-step, room-temperature, high-speed, gas-phase plasma polymerization process for functionalizing gold substrates using siloxane as an adhesion layer and acrylic acid as a functional layer. Siloxane- and thiol-based coatings were compared for their performance as adhesion and the interfacial layer for subsequent functionalization. An in situ sequential deposition of siloxane and acrylic acid resulted in a 7-fold increase in carboxylic functionality surfacial content compared to films deposited with thiol-containing precursors. Grading of the layer composition achieved as a consequence of ion-induced mixing on the surface coating under the application of the plasma is confirmed through secondary ion mass spectroscopic studies. DNA hybridization assays were demonstrated on gold/glass substrates using surface plasmon enhanced ellipsometry and the applicability of this coating for protein immunoassays were demonstrated with plasma functionalized gold/plastic substrates in Biacore 3000 SPR instrument.
Collapse
Affiliation(s)
- Ram P Gandhiraman
- Biomedical Diagnostics Institute (BDI), Dublin City University, Glasnevin, Dublin-9, Ireland.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Maalouli N, Gouget-Laemmel AC, Pinchemel B, Bouazaoui M, Chazalviel JN, Ozanam F, Yang Y, Burkhard P, Boukherroub R, Szunerits S. Development of a metal-chelated plasmonic interface for the linking of His-peptides with a droplet-based surface plasmon resonance read-off scheme. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:5498-5505. [PMID: 21480606 DOI: 10.1021/la2005437] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Monolayers of metal complexes were covalently attached to the surface of lamellar SPR interfaces (Ti/Ag/a-Si(0.63)C(0.37)) for binding histidine-tagged peptides with a controlled molecular orientation. The method is based on the activation of surface acid groups with N-hydroxysuccinimide (NHS), followed by an amidation reaction with (S)-N-(5-amino-1-carboxypentyl)iminodiacetic acid (NTA). FTIR and X-ray photoelectron spectroscopy (XPS) were used to characterize each surface modification step. The NTA modified SPR interface effectively chelated Cu(2+) ions. Once loaded with metal ions, the modified SPR interface was able to bind specifically to histidine-tagged peptides. The binding process was followed by surface plasmon resonance (SPR) in a droplet based configuration. The Cu(2+)-NTA modified interface showed protein loading comparable to commercially available NTA chips based on dextran chemistry and can thus be regarded as an interesting alternative. The sensor interface can be reused several times due to the easy regeneration step using ethylenediaminetetraacetic acid (EDTA) treatment.
Collapse
Affiliation(s)
- Nazek Maalouli
- Institut de Recherche Interdisciplinaire (USR 3078), Université Lille Nord de France, Parc de la Haute Borne, 50 Avenue de Halley, BP 70478, 59658 Villeneuve d'Ascq, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Linman MJ, Abbas A, Cheng Q. Interface design and multiplexed analysis with surface plasmon resonance (SPR) spectroscopy and SPR imaging. Analyst 2010; 135:2759-67. [PMID: 20830330 PMCID: PMC7365140 DOI: 10.1039/c0an00466a] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Ever since the advent of surface plasmon resonance (SPR) and SPR imaging (SPRi) in the early 1990s, their use in biomolecular interaction analysis (BIA) has expanded phenomenally. An important research area in SPR sensor development is the design of novel and effective interfaces that allow for the probing of a variety of chemical and biological interactions in a highly selective and sensitive manner. A well-designed and robust interface is a necessity to obtain both accurate and pertinent biological information. This review covers the recent research efforts in this area with a specific focus towards biointerfaces, new materials for SPR biosensing, and novel array designs for SPR imaging. Perspectives on the challenges ahead and next steps for SPR technology are discussed.
Collapse
Affiliation(s)
- Matthew J. Linman
- Department of Chemistry, University of California, Riverside, California 92521
| | - Abdennour Abbas
- Department of Chemistry, University of California, Riverside, California 92521
| | - Quan Cheng
- Department of Chemistry, University of California, Riverside, California 92521
| |
Collapse
|