1
|
Scharnweber D, Bierbaum S, Wolf-Brandstetter C. Utilizing DNA for functionalization of biomaterial surfaces. FEBS Lett 2018; 592:2181-2196. [PMID: 29683477 DOI: 10.1002/1873-3468.13065] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 03/27/2018] [Accepted: 04/16/2018] [Indexed: 02/06/2023]
Abstract
DNA sequences are widely used for gene transfer into cells including a number of substrate surface-based supporting systems, but due to its singular structure property profile, DNA also offers multiple options for noncanonical applications. The special case of using DNA and oligodeoxyribonucleotide (ODN) structures for surface functionalization of biomedical implants is summarized here with the major focus on (a) immobilization or anchoring of nucleic acid structures on substrate surfaces, (b) incorporation of biologically active molecules (BAM) into such systems, and (c) biological characteristics of the resulting surfaces in vitro and in vivo. Sterilizations issues, important for potential clinical applications, are also considered.
Collapse
Affiliation(s)
- Dieter Scharnweber
- Max Bergmann Center of Biomaterials, Technische Universität Dresden, Germany
| | - Susanne Bierbaum
- Max Bergmann Center of Biomaterials, Technische Universität Dresden, Germany.,International Medical College, Münster, Germany
| | | |
Collapse
|
2
|
Strąkowska P, Beutner R, Gnyba M, Zielinski A, Scharnweber D. Electrochemically assisted deposition of hydroxyapatite on Ti6Al4V substrates covered by CVD diamond films - Coating characterization and first cell biological results. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 59:624-635. [PMID: 26652416 DOI: 10.1016/j.msec.2015.10.063] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2015] [Revised: 09/23/2015] [Accepted: 10/20/2015] [Indexed: 01/30/2023]
Abstract
Although titanium and its alloys are widely used as implant material for orthopedic and dental applications they show only limited corrosion stability and osseointegration in different cases. The aim of the presented research was to develop and characterize a novel surface modification system from a thin diamond base layer and a hydroxyapatite (HAp) top coating deposited on the alloy Ti6Al4V widely used for implants in contact with bone. This coating system is expected to improve both the long-term corrosion behavior and the biocompatibility and bioactivity of respective surfaces. The diamond base films were obtained by Microwave Plasma Assisted Chemical Vapor Deposition (MW-PACVD); the HAp coatings were formed in aqueous solutions by electrochemically assisted deposition (ECAD) at varying polarization parameters. Scanning electron microscopy (SEM), Raman microscopy, and electrical conductivity measurements were applied to characterize the generated surface states; the calcium phosphate coatings were additionally chemically analyzed for their composition. The biological properties of the coating system were assessed using hMSC cells analyzing for cell adhesion, proliferation, and osteogenic differentiation. Varying MW-PACVD process conditions resulted in composite coatings containing microcrystalline diamond (MCD/Ti-C), nanocrystalline diamond (NCD), and boron-doped nanocrystalline diamond (B-NCD) with the NCD coatings being dense and homogeneous and the B-NCD coatings showing increased electrical conductivity. The ECAD process resulted in calcium phosphate coatings from stoichiometric and non-stoichiometric HAp. The deposition of HAp on the B-NCD films run at lower cathodic potentials and resulted both in the highest coating mass and the most homogenous appearance. Initial cell biological investigations showed an improved cell adhesion in the order B-NCD>HAp/B-NCD>uncoated substrate. Cell proliferation was improved for both investigated coatings whereas ALP expression was highest for the uncoated substrate.
Collapse
Affiliation(s)
- Paulina Strąkowska
- Gdańsk University of Technology, Mechanical Engineering Faculty, Poland; Gdańsk University of Technology, Faculty of Electronics, Telecommunications, and Informatics, Poland
| | - René Beutner
- Max Bergmann Center, Technische Universität Dresden, Germany
| | - Marcin Gnyba
- Gdańsk University of Technology, Faculty of Electronics, Telecommunications, and Informatics, Poland
| | - Andrzej Zielinski
- Gdańsk University of Technology, Mechanical Engineering Faculty, Poland
| | | |
Collapse
|
3
|
Pozio A. Effect of Tantalum Doping on TiO<sub>2</sub> Nanotube Arrays for Water-Splitting. ACTA ACUST UNITED AC 2015. [DOI: 10.4236/mrc.2015.41001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
4
|
Effect of Low Cobalt Loading on TiO2Nanotube Arrays for Water-Splitting. INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY 2014. [DOI: 10.1155/2014/904128] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
This work is intended to define a new possible methodology for the TiO2doping through the use of an electrochemical deposition of cobalt directly on the titanium nanotubes obtained by a previous galvanostatic anodization treatment in an ethylene glycol solution. This method does not seem to cause any influence on the nanotube structure, showing final products with news and interesting features with respect to the unmodified sample. Together with an unmodified photoconversion efficiency under UV light, the cobalt doped specimen reports an increase of the electrocatalytic efficiency for the oxygen evolution reaction (OER).
Collapse
|
5
|
Löberg J, Gretzer C, Mattisson I, Ahlberg E. Electronic properties of anodized TiO2 electrodes and the effect on in vitro response. J Biomed Mater Res B Appl Biomater 2013; 102:826-39. [PMID: 24259480 DOI: 10.1002/jbm.b.33065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2013] [Revised: 09/10/2013] [Accepted: 09/27/2013] [Indexed: 11/12/2022]
Abstract
For dental implants, improved osseointegration is obtained by modifying the surface roughness as well as oxide morphology and composition. A combination of different effects contributes to enhanced performance, but with surface roughness as the dominant factor. To single out the effect of oxide conductivity on biological response, oxide films with similar thickness and surface roughness but different electronic properties were formed using galvanostatic anodization. Three different current densities were used, 2.4, 4.8, and 11.9 mA cm(-2) , which resulted in growth rates ranging from 0.2 to 2.5 V s(-1) . The electronic properties were evaluated using cyclic voltammetry and impedance spectroscopy, while the biological response was studied by cell activity and apatite formation. The number of charge carrier in the oxide film close to the oxide/solution interface decreased from 5.8 × 10(-19) to 3.2 × 10(-19) cm(-2) with increasing growth rate, that is, the conductivity decreased correspondingly. Cell response of the different surfaces was tested in vitro using human osteoblast-like cells (MG-63). The results clearly show decreased osteoblast proliferation and adhesion but higher mineralization activity for the oxide with lower conductivity at the oxide/solution interface. The apatite-forming ability was examined by immersion in simulated body fluid. At short times the apatite coverage was ∼26% for the anodized surfaces, significantly larger than for the reference with only 3% coverage. After 1 week of immersion the apatite coverage ranged from 73 to 56% and a slight differentiation between the anodized surfaces was obtained with less apatite formation on the surface with lower conductivity, in line with the cell culture results.
Collapse
Affiliation(s)
- Johanna Löberg
- Department of Chemistry and Molecular Biology, University of Gothenburg, SE-412 96, Gothenburg, Sweden; Dentsply Implants, Box 14, SE-431 21, Mölndal, Sweden
| | | | | | | |
Collapse
|
6
|
Tsaryk R, Peters K, Barth S, Unger RE, Scharnweber D, Kirkpatrick CJ. The role of oxidative stress in pro-inflammatory activation of human endothelial cells on Ti6Al4V alloy. Biomaterials 2013; 34:8075-85. [DOI: 10.1016/j.biomaterials.2013.07.030] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Accepted: 07/08/2013] [Indexed: 12/21/2022]
|
7
|
Tsaryk R, Peters K, Unger RE, Feldmann M, Hoffmann B, Heidenau F, Kirkpatrick CJ. Improving cytocompatibility of Co28Cr6Mo by TiO2 coating: gene expression study in human endothelial cells. J R Soc Interface 2013; 10:20130428. [PMID: 23825117 DOI: 10.1098/rsif.2013.0428] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
Cobalt-based materials are widely used for coronary stents, as well as bone and joint implants. However, their use is associated with high corrosion incidence. Titanium alloys, by contrast, are more biocompatible owing to the formation of a relatively inactive titanium oxide (TiO2) layer on their surface. This study was aimed at improving Co28Cr6Mo alloy cytocompatibility via sol-gel TiO2 coating to reduce metal corrosion and metal ion release. Owing to their role in inflammation and tissue remodelling around an implant, endothelial cells present a suitable in vitro model for testing the biological response to metallic materials. Primary human endothelial cells seeded on Co28Cr6Mo showed a stress phenotype with numerous F-actin fibres absent on TiO2-coated material. To investigate this effect at the gene expression level, cDNA microarray analysis of in total 1301 genes was performed. Compared with control cells, 247 genes were expressed differentially in the cells grown on Co28Cr6Mo, among them genes involved in proliferation, oxidative stress response and inflammation. TiO2 coating reduced the effects of Co28Cr6Mo on gene expression in endothelial cells, with only 34 genes being differentially expressed. Quantitative real-time polymerase chain reaction and protein analysis confirmed microarray data for selected genes. The effect of TiO2 coating can be, in part, attributed to the reduced release of Co(2+), because addition of CoCl2 resulted in similar cellular responses. TiO2 coating of cobalt-based materials, therefore, could be used in the production of cobalt-based devices for cardiovascular and skeletal applications to reduce the adverse effects of metal corrosion products and to improve the response of endothelial and other cell types.
Collapse
Affiliation(s)
- R Tsaryk
- Institute of Pathology, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.
| | | | | | | | | | | | | |
Collapse
|
8
|
Ievlev VM. Coatings based on calcium phosphates for metallic medical implants. RUSSIAN CHEMICAL REVIEWS 2013. [DOI: 10.1070/rc2013v082n02abeh004331] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
9
|
Bhola R, Su F, Krull CE. Functionalization of titanium based metallic biomaterials for implant applications. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2011; 22:1147-1159. [PMID: 21476077 DOI: 10.1007/s10856-011-4305-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2011] [Accepted: 03/24/2011] [Indexed: 05/27/2023]
Abstract
Surface immobilization with active functional molecules (AFMs) on a nano-scale is a main field in the current biomaterial research. The functionalization of a vast number of substances and molecules, ranging from inorganic calcium phosphates, peptides and proteins, has been investigated throughout recent decades. However, in vitro and in vivo results are heterogeneous. This may be attributed partially to the limits of the applied immobilization methods. Therefore, this paper highlights the advantages and limitations of the currently applied methods for the biological nano-functionalization of titanium-based biomaterial surfaces. The second part describes a newer immobilization system, using the nanomechanical fixation of at least partially single-stranded nucleic acids (NAs) into an anodic titanium oxide layer as an immobilization principle and their hybridization ability for the functionalization of the surface with active functional molecules conjugated to the respective complementary NA strands.
Collapse
Affiliation(s)
- Rahul Bhola
- Department of Biologic and Material Sciences, School of Dentistry, University of Michigan, Ann Arbor, MI 48109, USA.
| | | | | |
Collapse
|
10
|
Despang F, Bernhardt A, Lode A, Hanke T, Handtrack D, Kieback B, Gelinsky M. Response of human bone marrow stromal cells to a novel ultra-fine-grained and dispersion-strengthened titanium-based material. Acta Biomater 2010; 6:1006-13. [PMID: 19800426 DOI: 10.1016/j.actbio.2009.09.026] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2009] [Revised: 08/20/2009] [Accepted: 09/28/2009] [Indexed: 01/14/2023]
Abstract
A novel titanium-based material, containing no toxic or expensive alloying elements, was compared to the established biomaterials: commercially pure titanium (c.p.Ti) and Ti6Al4V. This material (Ti/1.3HMDS) featured similar hardness, yield strength and better wear resistance than Ti6Al4V, as well as better electrochemical properties at physiological pH7.4 than c.p.Ti grade 1 of our study. These excellent properties were obtained by utilizing an alternative mechanism to produce a microstructure of very fine titanium silicides and carbides (<100 nm) embedded in an ultra-fine-grained Ti matrix (365 nm). The grain refinement was achieved by high-energy ball milling of Ti powder with 1.3 wt.% of hexamethyldisilane (HMDS). The powder was consolidated by spark plasma sintering at moderate temperatures of 700 degrees C. The microstructure was investigated by optical and scanning electron microscopy (SEM) and correlated to the mechanical properties. Fluorescence microscopy revealed good adhesion of human mesenchymal stem cells on Ti/1.3HMDS comparable to that on c.p.Ti or Ti6Al4V. Biochemical analysis of lactate dehydrogenase and specific alkaline phosphatase activities of osteogenically induced hMSC exhibited equal proliferation and differentiation rates in all three cases. Thus the new material Ti/1.3HMDS represents a promising alternative to the comparatively weak c.p.Ti and toxic elements containing Ti6Al4V.
Collapse
Affiliation(s)
- F Despang
- Institute for Materials Science and Max Bergmann Center of Biomaterials, Technische Universität Dresden, Budapester Strasse 27, D-01069 Dresden, Germany.
| | | | | | | | | | | | | |
Collapse
|
11
|
Beutner R, Michael J, Schwenzer B, Scharnweber D. Biological nano-functionalization of titanium-based biomaterial surfaces: a flexible toolbox. J R Soc Interface 2010; 7 Suppl 1:S93-S105. [PMID: 19889692 PMCID: PMC2843991 DOI: 10.1098/rsif.2009.0418.focus] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2009] [Accepted: 10/14/2009] [Indexed: 11/12/2022] Open
Abstract
Surface functionalization with bioactive molecules (BAMs) on a nanometre scale is a main field in current biomaterial research. The immobilization of a vast number of substances and molecules, ranging from inorganic calcium phosphate phases up to peptides and proteins, has been investigated throughout recent decades. However, in vitro and in vivo results are heterogeneous. This may be at least partially attributed to the limits of the applied immobilization methods. Therefore, this paper highlights, in the first part, advantages and limits of the currently applied methods for the biological nano-functionalization of titanium-based biomaterial surfaces. The second part describes a new immobilization system recently developed in our groups. It uses the nanomechanical fixation of at least partially single-stranded nucleic acids (NAs) into an anodic titanium oxide layer as an immobilization principle and their hybridization ability for the functionalization of the surface with BAMs conjugated to the respective complementary NA strands.
Collapse
Affiliation(s)
- René Beutner
- Max Bergmann Center of Biomaterials, TU Dresden, Budapester Strasse 27, 01069 Dresden, Germany
| | - Jan Michael
- Chair of Biochemistry, Department of Chemistry, TU Dresden, Bergstr. 66, 01069 Dresden, Germany
| | - Bernd Schwenzer
- Chair of Biochemistry, Department of Chemistry, TU Dresden, Bergstr. 66, 01069 Dresden, Germany
| | - Dieter Scharnweber
- Max Bergmann Center of Biomaterials, TU Dresden, Budapester Strasse 27, 01069 Dresden, Germany
| |
Collapse
|
12
|
Beutner R, Michael J, Förster A, Schwenzer B, Scharnweber D. Immobilization of oligonucleotides on titanium based materials by partial incorporation in anodic oxide layers. Biomaterials 2009; 30:2774-81. [PMID: 19232713 DOI: 10.1016/j.biomaterials.2009.01.047] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2008] [Accepted: 01/27/2009] [Indexed: 11/25/2022]
Abstract
This paper describes the immobilization of bioactive molecules on titanium based surfaces through a combination of nano-mechanical fixation of nucleic acid anchor strands (ASs) by partial and regioselective incorporation within an anodic oxide layer and their hybridization with complementary strands (CSs) intended to be conjugated to bioactive molecules. We focus on the interaction between the substrate surface and the anchor strands, the integrity of ASs and their hybridization ability. The observed dependence of adsorption on pH suggests that initial interaction of terminally phosphorylated ASs with the substrate surface is mediated by electrostatic interaction. Using ASs labelled with (32)P at different termini, it could be shown that strand breaks occur, which are attributed (i) to the formation of reactive oxygen species during anodic polarization, (ii) the photocatalytic activity of the titanium oxide and (iii) drying effects. Damage to AS could be considerably reduced if the electrolyte contained 5 mol l(-1) ethanol, light was excluded during the experimental procedure, and the number of drying and rewetting steps was minimized. A total surface density of AS of 4.5 pmol cm(-2) was reached and could be hybridized to CS with an efficiency of up to 100%. A non-complementary strand (NS) bound with less than 0.5% of the amount of CS under similar conditions. Therefore, non-specific binding of CS is considered as negligible.
Collapse
Affiliation(s)
- René Beutner
- Max Bergmann Centre of Biomaterials, TU Dresden, Budapester Str. 27, 01069 Dresden, Germany.
| | | | | | | | | |
Collapse
|
13
|
Vamanu CI, Høl PJ, Allouni ZE, Elsayed S, Gjerdet NR. Formation of potential titanium antigens based on protein binding to titanium dioxide nanoparticles. Int J Nanomedicine 2008; 3:69-74. [PMID: 18488417 PMCID: PMC2526361 DOI: 10.2147/ijn.s1796] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Degradation products of titanium implants include free ions, organo-metallic complexes, and particles, ranging from nano to macro sizes. The biological effects, especially of nanoparticles, is yet unknown. The main objective of this study was to develop Ti-protein antigens in physiological solutions that can be used in testing of cellular responses. For this purpose, 0.1% TiO2 nanoparticles less than 100 nm were mixed with human serum albumin (HSA), 0.1% and 1%, in cell culture medium (DMEM, pH 7.2). The Ti concentrations in the resulting solutions were analyzed by inductively coupled plasma mass spectrometry. The stability of the nanoparticles in suspension was analyzed by UV-vis spectrophotometer and Dynamic Light Scattering. The concentration of Ti in suspension was dependent on the presence and concentration of HSA. Albumin prevented high aggregation rate of TiO2 nanoparticles in cell culture medium. It is shown that nano TiO2-protein stable aggregates can be produced under physiological conditions at high concentrations, and are candidates for use in cellular tests.
Collapse
Affiliation(s)
- Carmen Irina Vamanu
- Department of Oral Sciences, Faculty of Dentistry, University of Bergen, Bergen, Norway.
| | | | | | | | | |
Collapse
|
14
|
Sahlin H, Contreras R, Gaskill DF, Bjursten LM, Frangos JA. Anti-inflammatory properties of micropatterned titanium coatings. J Biomed Mater Res A 2006; 77:43-9. [PMID: 16345099 DOI: 10.1002/jbm.a.30642] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Prolonged inflammation and reactive oxygen species (ROS) generated around an implanted biosensor are the primary causes of the foreign body response, including encapsulation of biosensor membranes. We have previously demonstrated that TiO2 surfaces reduce ROS. Here we investigated the potential of using the anti-inflammatory properties of TiO2 in the design of biosensor membranes with improved long-term in vivo transport properties. Micropatterned Ti films were sputtered onto quartz surfaces in a series of hexagonally distributed dots with identical coverage area of 23% and dot size ranging from 5 to 100 microm. The antioxidant effect of the surfaces was investigated using a cell-free peroxynitrite donor assay and assays of superoxide released from stimulated surface-adhering neutrophils and macrophages. In all three assays, the amount of ROS was monitored using luminol-amplified chemiluminescence. Patterned surfaces in all experimental models significantly decreased ROS compared to the etched surfaces. In the cell-free experiment, the ROS reduction was only dependent on fractional surface coverage. In the cell experiments, however, a dot-size-dependent ROS reduction was seen, with the largest reduction at the smallest dot-size surfaces. These results indicate that micropatterned surfaces with small dots covering only 23% of the surface area exhibit similar antioxidative effect as fully covered surfaces.
Collapse
Affiliation(s)
- Herman Sahlin
- La Jolla Bioengineering Institute, 505 Coast Boulevard South, La Jolla, California 92037, USA
| | | | | | | | | |
Collapse
|
15
|
Müller R, Abke J, Schnell E, Scharnweber D, Kujat R, Englert C, Taheri D, Nerlich M, Angele P. Influence of surface pretreatment of titanium- and cobalt-based biomaterials on covalent immobilization of fibrillar collagen. Biomaterials 2006; 27:4059-68. [PMID: 16580064 DOI: 10.1016/j.biomaterials.2006.03.019] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2006] [Accepted: 03/10/2006] [Indexed: 10/24/2022]
Abstract
Collagen type-I is a major component of the extracellular matrix of most tissues and it is increasingly utilized for surface engineering of biomaterials to accelerate receptor-mediated cell adhesion. In the present study, coatings with layers of fibrillar type-I collagen were prepared on titanium, titanium alloy, and cobalt alloy to improve initial osteoblast adhesion and implant-tissue integration. To suppress the quick in vivo degradation rate of collagen the deposited layers were covalently immobilized at the metal surfaces as well as chemically cross-linked. The application of different oxidation techniques to the metallic substrates resulted in surfaces with varying hydroxyl group contents, which directly influenced the amount of immobilized silane coupling agents. It was found that a high density of surface-bound coupling agents increased the stability of the covalently linked collagen layers. After coating of metallic biomaterials with a cross-linked collagen layer, an improved cellular response of human osteoblast-like cells (MG-63) in vitro could be recognized.
Collapse
Affiliation(s)
- Rainer Müller
- Institute of Physical and Theoretical Chemistry, University of Regensburg, Universitätsstrasse 31, 93053 Regensburg, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Baunack S, Oswald S. Application of factor analysis in electron spectrometry (AES, XPS) for materials science. ACTA ACUST UNITED AC 2005. [DOI: 10.3139/146.101128] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
17
|
Eisenbarth E, Velten D, Müller M, Thull R, Breme J. Biocompatibility of β-stabilizing elements of titanium alloys. Biomaterials 2004; 25:5705-13. [PMID: 15147816 DOI: 10.1016/j.biomaterials.2004.01.021] [Citation(s) in RCA: 239] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2003] [Accepted: 01/17/2004] [Indexed: 11/19/2022]
Abstract
In comparison to the presently used alpha + beta titanium alloys for biomedical applications, beta-titanium alloys have many advantageous mechanical properties, such as an improved wear resistance, a high elasticity and an excellent cold and hot formability. This will promote their future increased application as materials for orthopaedic joint replacements. Not all elements with beta-stabilizing properties in titanium alloys are suitable for biomaterial applications-corrosion and wear processes cause a release of these alloying elements to the surrounding tissue. In this investigation, the biocompability of alloying elements for beta- and near beta-titanium alloys was tested in order to estimate their suitability for biomaterial components. Titanium (grade 2) and the implant steel X2CrNiMo18153 (AISI 316 L) were tested as reference materials. The investigation included the corrosion properties of the elements, proliferation, mitochondrial activity, cell morphology and the size of MC3T3-E1 cells and GM7373 cells after 7 days incubation in direct contact with polished slices of the metals. The statistical significance was considered by Weir-test and Lord-test (alpha = 0.05). The biocompatibility range of the investigated metals is (decreasing biocompatibility): niobium-tantalum, titanium, zirconium-aluminium-316 L-molybdenum.
Collapse
Affiliation(s)
- E Eisenbarth
- Universität des Saarlandes, Lehrstuhl für metallische Werkstoffe, D-66041 Saarbrücken, Germany.
| | | | | | | | | |
Collapse
|
18
|
Scharnweber D, Born R, Flade K, Roessler S, Stoelzel M, Worch H. Mineralization behaviour of collagen type I immobilized on different substrates. Biomaterials 2004; 25:2371-80. [PMID: 14741602 DOI: 10.1016/j.biomaterials.2003.09.025] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Collagen type I as a robust fibre protein and main component of the extracellular matrix of most tissues is increasingly utilized for surface engineering of biomaterials using different immobilization methods. In the present work we studied the mineralization behaviour of fibrillar collagen type I in simulated body fluid as a measure for conformational changes caused by adsorptive immobilization or immobilization by partial incorporation into the anodic oxide layer on c.p.-titanium using microscopic and vibration spectroscopic methods. Adsorptive immobilization on highly oriented pyrolytic graphite (HOPG) and c.p.-titanium without collagen were used as references. In the initial phase (1-24 h) the kinetics of formation and the morphology of calcium phosphate phases (CPP) are strongly influenced both by the substrate and the immobilization method. Compared to HOPG both types of immobilization on titanium increasingly inhibit the formation of CPP. For longer times (30 d) these initial differences disappear-mineralization product on titanium, irrespective of the presence of collagen, is a mixture of amorphous calcium phosphate and octacalcium phosphate. Contrary to this the mineralization of HOPG substrates results in hydroxy apatite. This is discussed with respect to the conditions during the immobilization as well as the resulting interactions between substrate and immobilized collagen. It is shown that the mineralization process exhibits a high sensitivity with respect to conformational changes caused by these interactions. Possible cell biological relevance of these conformational changes is discussed.
Collapse
Affiliation(s)
- Dieter Scharnweber
- Institute of Materials Science, Max-Bergmann-Zentrum fur Biomaterialien, TU Dresden, Budapester Strasse 27, Dresden 01069, Germany.
| | | | | | | | | | | |
Collapse
|