1
|
Amperometric Biosensor Based on Laccase Enzyme, Gold Nanoparticles, and Glutaraldehyde for the Determination of Dopamine in Biological and Environmental Samples. Mol Vis 2022. [DOI: 10.3390/c8030040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The present work reports the development and application of an amperometric biosensor based on carbon paste electrode modified with laccase enzyme, glutaraldehyde, and gold nanoparticles (Lac-Glu-AuNPs/CPE) for the determination of the neurotransmitter dopamine (DA). The materials were characterized morphologically and chemically using scanning electron microscopy (SEM), transmission electron microscopy (TEM), and cyclic voltammetry. Optimization studies were performed in order to determine the optimal amount of enzyme and pH level that can yield the best conditions of analysis. The application of the biosensor in optimal conditions using the amperometric technique yielded a linear concentration range of 8.0 × 10−7–6.2 × 10−5 mol L−1 with a limit of detection of 6.0 × 10−8 mol L−1. The proposed biosensor was successfully applied for the determination of DA in biological and environmental samples. In addition, the application of the biosensor for the conduct of electrochemical measurements showed that the sensing device has good repeatability and stability, and it does not suffer from matrix interference effects. The proposed biosensor exhibited an analytical signal of 85% after 10 days of consecutive use.
Collapse
|
2
|
Baluta S, Meloni F, Halicka K, Szyszka A, Zucca A, Pilo MI, Cabaj J. Differential pulse voltammetry and chronoamperometry as analytical tools for epinephrine detection using a tyrosinase-based electrochemical biosensor. RSC Adv 2022; 12:25342-25353. [PMID: 36199318 PMCID: PMC9446417 DOI: 10.1039/d2ra04045j] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 09/01/2022] [Indexed: 12/20/2022] Open
Abstract
The main goal of the presented study was to design a biosensor-based system for epinephrine (EP) detection using a poly-thiophene derivative and tyrosinase as a biorecognition element. We compared two different electroanalytical techniques to select the most prominent technique for analyzing the neurotransmitter. The prepared biosensor system exhibited good parameters; the differential pulse (DPV) technique presented a wide linear range (1–20 μM and 30–200 μM), with a low detection limit (0.18 nM and 1.03 nM). In the case of chronoamperometry (CA), a high signal-to-noise ratio and lower reproducibility were observed, causing a less broad linear range (10–200 μM) and a higher detection limit (125 nM). Therefore, the DPV technique was used for the calculation of sensitivity (0.0011 μA mM−1 cm−2), stability (49 days), and total surface coverage (4.18 × 10−12 mol cm−2). The biosensor also showed very high selectivity in the presence of common interfering species (i.e. ascorbic acid, uric acid, norepinephrine, dopamine) and was successfully applied for EP determination in a pharmaceutical sample. GCE/poly-4,4′-bBT/tyrosinase biosensor for epinephrine was constructed. Comparison of differential pulse voltammetry (DPV) and chronoamperometry was performed. DPV showed more reproducible results giving high selectivity, sensitivity, stability.![]()
Collapse
Affiliation(s)
- Sylwia Baluta
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Francesca Meloni
- Department of Chemistry and Pharmacy, University of Sassari, Via Vienna 2, 07100 Sassari, Italy
| | - Kinga Halicka
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Adam Szyszka
- Faculty of Microsystem Electronics and Photonics, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Antonio Zucca
- Department of Chemistry and Pharmacy, University of Sassari, Via Vienna 2, 07100 Sassari, Italy
| | - Maria Itria Pilo
- Department of Chemistry and Pharmacy, University of Sassari, Via Vienna 2, 07100 Sassari, Italy
| | - Joanna Cabaj
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| |
Collapse
|
3
|
Hira SA, Nagappan S, Annas D, Kumar YA, Park KH. NO2-functionalized metal–organic framework incorporating bimetallic alloy nanoparticles as a sensor for efficient electrochemical detection of dopamine. Electrochem commun 2021. [DOI: 10.1016/j.elecom.2021.107012] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
4
|
Elugoke SE, Adekunle AS, Fayemi OE, Mamba BB, Sherif ESM, Ebenso EE. Carbon-Based Quantum Dots for Electrochemical Detection of Monoamine Neurotransmitters-Review. BIOSENSORS 2020; 10:E162. [PMID: 33142771 PMCID: PMC7693402 DOI: 10.3390/bios10110162] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Revised: 08/09/2020] [Accepted: 08/12/2020] [Indexed: 12/13/2022]
Abstract
Imbalance in the levels of monoamine neurotransmitters have manifested in severe health issues. Electrochemical sensors have been designed for their determination, with good sensitivity recorded. Carbon-based quantum dots have proven to be an important component of electrochemical sensors due to their high conductivity, low cytotoxicity and opto-electronic properties. The quest for more sensitive electrodes with cheaper materials led to the development of electrochemical sensors based on carbon-based quantum dots for the detection of neurotransmitters. The importance of monoamine neurotransmitters (NTs) and the good electrocatalytic activity of carbon and graphene quantum dots (CQDs and GQDs) make the review of the efforts made in the design of such sensors for monoamine NTs of huge necessity. The differences and the similarities between these two quantum dots are highlighted prior to a discussion of their application in electrochemical sensors over the last ten years. Compared to other monoamine NTs, dopamine (DA) was the most studied with GQDs and CQD-based electrochemical sensors.
Collapse
Affiliation(s)
- Saheed E. Elugoke
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Mmabatho 2735, South Africa; (S.E.E.); (A.S.A.); (O.E.F.)
- Department of Chemistry, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Mmabatho 2735, South Africa
| | - Abolanle S. Adekunle
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Mmabatho 2735, South Africa; (S.E.E.); (A.S.A.); (O.E.F.)
- Department of Chemistry, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Mmabatho 2735, South Africa
- Department of Chemistry, Obafemi Awolowo University, Ile-Ife 220005, Nigeria
| | - Omolola E. Fayemi
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Mmabatho 2735, South Africa; (S.E.E.); (A.S.A.); (O.E.F.)
- Department of Chemistry, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Mmabatho 2735, South Africa
| | - Bhekie B. Mamba
- Nanotechnology and Water Sustainability Research Unit, College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa;
| | - El-Sayed M. Sherif
- Center of Excellence for Research in Engineering Materials (CEREM), King Saud University, P.O. Box 800, Al-Riyadh 11421, Saudi Arabia;
- Electrochemistry and Corrosion Laboratory, Department of Physical Chemistry, National Research Centre, Cairo 12622, Egypt
| | - Eno E. Ebenso
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Mmabatho 2735, South Africa; (S.E.E.); (A.S.A.); (O.E.F.)
- Department of Chemistry, College of Science, Engineering and Technology, University of South Africa, Roodepoort 1710, South Africa
| |
Collapse
|
5
|
Hira SA, Nallal M, Rajendran K, Song S, Park S, Lee JM, Joo SH, Park KH. Ultrasensitive detection of hydrogen peroxide and dopamine using copolymer-grafted metal-organic framework based electrochemical sensor. Anal Chim Acta 2020; 1118:26-35. [PMID: 32418601 DOI: 10.1016/j.aca.2020.04.043] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 04/13/2020] [Accepted: 04/18/2020] [Indexed: 01/05/2023]
Abstract
We reported the synthesis of a copolymer- and metal-organic framework-based electrochemical sensor, UiO-66-NH2@P(ANI-co-ANA) using the polymerization method for the highly sensitive and selective detection of hydrogen peroxide (H2O2) and dopamine (DA). The as-synthesized material was characterized via Fourier transform infrared spectroscopy, X-ray diffraction analysis, scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and thermogravimetric analysis. The electrochemical characteristics of the proposed sensor were evaluated via impedance spectroscopy and cyclic voltammetry (CV). The electrochemical oxidation of DA and the reduction of H2O2 were determined via CV, square-wave voltammetry, and chronoamperometric techniques. The fabricated sensor exhibited a wide linear range of 25-500 μM, with a sensitivity of 1396.1 μAμM-1cm-2 and a limit of detection of 0.6 μM, for the electrochemical reduction of H2O2. Additionally, it exhibited a wide linear range of 10-110 μM, with a sensitivity of 1110.2 μAμM-1cm-2 and a limit of detection of 0.3 μM, for the electrochemical detection of DA. The practical utility of the fabricated sensor was evaluated via the detection of H2O2 in milk samples and DA in human urine samples.
Collapse
Affiliation(s)
- Shamim Ahmed Hira
- Department of Chemistry, Pusan National University, Busan, 46241, South Korea
| | - Muthuchamy Nallal
- Department of Chemistry, Pusan National University, Busan, 46241, South Korea
| | - Karkuzhali Rajendran
- Department of Industrial Chemistry, Alagappa University, Karaikudi, 630003, Tamil Nadu, India
| | - Sehwan Song
- Department of Physics, Pusan National University, Busan, 46241, South Korea
| | - Sungkyun Park
- Department of Physics, Pusan National University, Busan, 46241, South Korea
| | - Jae-Myung Lee
- Department of Naval Architecture, Pusan National University, Busan, 46241, South Korea
| | - Sang Hoon Joo
- Department of Energy Engineering and School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan, 44919, South Korea
| | - Kang Hyun Park
- Department of Chemistry, Pusan National University, Busan, 46241, South Korea.
| |
Collapse
|
6
|
Fluorescence Sensing Platforms for Epinephrine Detection Based on Low Temperature Cofired Ceramics. SENSORS 2020; 20:s20051429. [PMID: 32151107 PMCID: PMC7085728 DOI: 10.3390/s20051429] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 02/27/2020] [Accepted: 03/03/2020] [Indexed: 12/14/2022]
Abstract
A novel fluorescence-sensing pathway for epinephrine (EP) detection was investigated. The ceramic-based miniature biosensor was developed through the immobilization of an enzyme (laccase, tyrosinase) on a polymer—poly-(2,6-di([2,2′-bithiophen]-5-yl)-4-(5-hexylthiophen-2-yl)pyridine), based on low temperature cofired ceramics technology (LTCC). The detection procedure was based on the oxidation of the substrate, i.e., in the presence of the enzyme. An alternative enzyme-free system utilized the formation of a colorful complex between Fe2+ ions and epinephrine molecules. With the optimized conditions, the analytical performance illustrated high sensitivity and selectivity in a broad linear range with a detection limit of 0.14–2.10 nM. Moreover, the strategy was successfully used for an EP injection test with labeled pharmacological samples.
Collapse
|
7
|
Baluta S, Zając D, Szyszka A, Malecha K, Cabaj J. Enzymatic Platforms for Sensitive Neurotransmitter Detection. SENSORS (BASEL, SWITZERLAND) 2020; 20:E423. [PMID: 31940833 PMCID: PMC7014284 DOI: 10.3390/s20020423] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 12/09/2019] [Accepted: 12/17/2019] [Indexed: 02/07/2023]
Abstract
A convenient electrochemical sensing pathway was investigated for neurotransmitter detection based on newly synthesized silole derivatives and laccase/horseradish-peroxidase-modified platinum (Pt)/gold (Au) electrodes. The miniature neurotransmitter's biosensors were designed and constructed via the immobilization of laccase in an electroactive layer of the Pt electrode coated with poly(2,6-bis(3,4-ethylenedioxythiophene)-4-methyl-4-octyl-dithienosilole) and laccase for serotonin (5-HT) detection, and a Au electrode modified with the electroconducting polymer poly(2,6-bis(selenophen-2-yl)-4-methyl-4-octyl-dithienosilole), along with horseradish peroxidase (HRP), for dopamine (DA) monitoring. These sensing arrangements utilized the catalytic oxidation of neurotransmitters to reactive quinone derivatives (the oxidation process was provided in the enzymes' presence). Under the optimized conditions, the analytical performance demonstrated a convenient degree of sensitivity: 0.0369 and 0.0256 μA mM-1 cm-2, selectivity in a broad linear range (0.1-200) × 10-6 M) with detection limits of ≈48 and ≈73 nM (for the serotonin and dopamine biosensors, respectively). Moreover, the method was successfully applied for neurotransmitter determination in the presence of interfering compounds (ascorbic acid, L-cysteine, and uric acid).
Collapse
Affiliation(s)
- Sylwia Baluta
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland; (D.Z.); (J.C.)
| | - Dorota Zając
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland; (D.Z.); (J.C.)
| | - Adam Szyszka
- Faculty of Microsystem Electronics and Photonics, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Karol Malecha
- Faculty of Microsystem Electronics and Photonics, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Joanna Cabaj
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland; (D.Z.); (J.C.)
| |
Collapse
|
8
|
Tolmacheva VV, Yarykin DI, Gorbunova MV, Apyari VV, Dmitrienko SG, Zolotov YA. Preconcentration of Catecholamins on Hypercrosslinked Polystyrene and Their Determination by High-Performance Liquid Chromatography. JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1134/s1061934819090107] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
9
|
Ribeiro JA, Fernandes PM, Pereira CM, Silva F. Electrochemical sensors and biosensors for determination of catecholamine neurotransmitters: A review. Talanta 2016; 160:653-679. [DOI: 10.1016/j.talanta.2016.06.066] [Citation(s) in RCA: 102] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2016] [Revised: 06/28/2016] [Accepted: 06/30/2016] [Indexed: 01/03/2023]
|
10
|
Alhendal A, Mengis S, Matthews J, Malik A. Nonhydrolytic sol-gel approach to facile creation of surface-bonded zirconia organic-inorganic hybrid coatings for sample preparation. Ι. Capillary microextraction of catecholamine neurotransmitters. J Chromatogr A 2016; 1468:23-32. [DOI: 10.1016/j.chroma.2016.09.036] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 09/12/2016] [Accepted: 09/19/2016] [Indexed: 10/21/2022]
|
11
|
Selective extraction and analysis of catecholamines in rat blood microdialysate by polymeric ionic liquid-diphenylboric acid-packed capillary column and fast separation in high-performance liquid chromatography-electrochemical detector. J Chromatogr A 2015. [DOI: 10.1016/j.chroma.2015.07.040] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
12
|
Claude B, Morin P, Denoroy L. SELECTIVE SOLID-PHASE EXTRACTION OF CATECHOLAMINES AND METANEPHRINES FROM SERUM USING A NEW MOLECULARLY IMPRINTED POLYMER. J LIQ CHROMATOGR R T 2014. [DOI: 10.1080/10826076.2013.853310] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Bérengère Claude
- a Institut de Chimie Organique et Analytique, Université Orléans , Orléans , France
| | - Philippe Morin
- a Institut de Chimie Organique et Analytique, Université Orléans , Orléans , France
| | - Luc Denoroy
- b Equipe BioRaN et Plate-forme NeuroChem, Centre de Recherche en Neurosciences de Lyon, Université Claude Bernard Lyon 1 , Lyon , France
| |
Collapse
|
13
|
Ribeiro JA, Silva F, Pereira CM. Electrochemical Sensing of Catecholamines at the Water/ 1,6-Dichlorohexane Interface. ELECTROANAL 2013. [DOI: 10.1002/elan.201300302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
14
|
Bouri M, Lerma-García MJ, Salghi R, Zougagh M, Ríos A. Selective extraction and determination of catecholamines in urine samples by using a dopamine magnetic molecularly imprinted polymer and capillary electrophoresis. Talanta 2012; 99:897-903. [PMID: 22967640 DOI: 10.1016/j.talanta.2012.07.053] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2012] [Revised: 07/14/2012] [Accepted: 07/19/2012] [Indexed: 11/15/2022]
Abstract
A rapid and selective method for the extraction and determination of catecholamines (CLs) from urine samples has been successfully developed using a magnetic molecularly imprinted polymer (MMIP) as a sorbent material. The MMIP has been prepared using dopamine hydrochloride (DA) as template molecule, methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylate (EDMA) as cross-linking agent and Fe(3)O(4) magnetite as magnetic component. The extraction was carried out by stirring urine samples with the magnetic polymer. When the extraction was completed, the MMIP, together with the captured analytes, was easily separated from the sample matrix by an adscititious magnet. The analytes desorbed from the MMIP were determined by capillary electrophoresis (CE). It was shown that the MMIP had high affinity and selectivity toward DA and other structurally related CLs such as 3-methoxytyramine hydrochloride (MT), DL-normetanephrine hydrochloride (NME), DL-norephinephrine hydrochloride (NE) and (±) epinephrine (E). Different parameters affecting the extraction efficiency were evaluated in order to achieve the optimal pre-concentration of the analytes and to reduce non-specific interactions. Under the optimal conditions, the CL limits of detection were at the 0.04-0.06 μM range. The relative standard deviations of migration time and response ranged from 0.7% to 1.4% and from 2.9% to 5.5%, respectively. The proposed method was successfully applied to determine CLs, including MT, NME, DA, NE and E in human urine samples.
Collapse
Affiliation(s)
- Mohamed Bouri
- Department of Analytical Chemistry and Food Technology, University of Castilla-La Mancha, Av. Camilo José Cela 10, E-13004, Ciudad Real, Spain
| | | | | | | | | |
Collapse
|
15
|
Claude B, Nehmé R, Morin P. Analysis of urinary neurotransmitters by capillary electrophoresis: Sensitivity enhancement using field-amplified sample injection and molecular imprinted polymer solid phase extraction. Anal Chim Acta 2011; 699:242-8. [DOI: 10.1016/j.aca.2011.05.014] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2011] [Revised: 05/02/2011] [Accepted: 05/09/2011] [Indexed: 10/18/2022]
|
16
|
Huang J, Fang H, Liu C, Gu E, Jiang D. A Novel Fiber Optic Biosensor for the Determination of Adrenaline Based on Immobilized Laccase Catalysis. ANAL LETT 2008. [DOI: 10.1080/00032710802119525] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
17
|
Abstract
This paper provides an overview on the current status of the analysis of biogenic amines by CE. The basic CE separation and detection strategies for the analysis of biogenic amines are briefly described. CZE and MEKC that provide highly efficient and reproducible analysis of biogenic amines are particularly surveyed. With respect to the detection of biogenic amines, we focus on LIF, UV-visible absorption, electrochemiluminescence, and MS. Derivatization strategies, indirect methods, and on-line concentration techniques such as field-amplified sample stacking, sweeping, and use of polymer solution are described. To show the practicality of CE, we highlight currently developed techniques for the determinations of biogenic amines in biological samples, including foods, beverages, cerebrospinal fluids, urine, and single cells.
Collapse
Affiliation(s)
- Tai-Chia Chiu
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | | | |
Collapse
|
18
|
Lin CE, Cheng HT, Fang IJ, Liu YC, Kuo CM, Lin WY, Lin CH. Strategies for enantioseparations of catecholamines and structurally related compounds by capillary zone electrophoresis using sulfated β-cyclodextrins as chiral selectors. Electrophoresis 2006; 27:3443-51. [PMID: 16944458 DOI: 10.1002/elps.200500658] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Strategies for simultaneous enantioseparations of three catecholamines (DL-norepinephrine, DL-epinephrine, and DL-isoproterenol) and three structurally related compounds (DL-octopamine, DL-synephrine, and DL-norephedrine) by CZE using sulfated beta-CDs as chiral selectors were investigated. Four different separation modes were attempted: (I) using randomly sulfate-substituted beta-CD (MI-S-beta-CD) at relatively low concentrations in a high-concentration phosphate buffer at low pH in the normal polarity mode, (II) using MI-S-beta-CD at high concentrations at low pH in the reversed polarity mode, (III) using MI-S-beta-CD at moderately high concentrations in a phosphate buffer at neutral pH in the normal polarity mode, and (IV) using the single isomer heptakis(2,3-dihydroxy-6-O-sulfo)-beta-CD (SI-S-beta-CD) at low to moderately high concentrations in a high-concentration BGE at low pH in the normal polarity mode. Among them, enantioseparation of these cationic solutes was best achieved under the conditions of mode (II). In mode (II) and mode (III), temperature is an important factor affecting the enantioresolution of norepinephrine. In mode (I) and mode (IV), the use of a high-concentration BGE (150-200 mM) is crucial for effective enantioseparation of these cationic solutes with sulfated beta-CDs. Comparative studies of enantioseparations of these cationic solutes with MI-S-beta-CD and SI-S-beta-CD reveal that the sulfate substituents of MI-S-beta-CD located at the C(2)- position interact strongly with the diol moiety of catecholamines.
Collapse
Affiliation(s)
- Ching-Erh Lin
- Department of Chemistry, National Taiwan University, Taipei, Taiwan.
| | | | | | | | | | | | | |
Collapse
|
19
|
Abstract
Detection of biogenic monoamines in nanomolar concentrations is of great importance for probing the brain chemistry and for their analytics in biological fluids. The sensitivity enhancement of amperometric detection of neurotransmitters (NTs) and their metabolites after their electrophoretic separation on a microchip is presented and is based on coupled enzymatic reactions. The current response of the analyte is amplified by cyclic oxidation on a gold electrode mediated by reduced nicotinamide dinucleotide coenzyme and glucose oxidase enzyme present in the electrophoresis buffer. Using this approach, detection limits of about 10 nM for NTs and their metabolites can be reached.
Collapse
Affiliation(s)
- Markéta Vlcková
- Department of Chemistry, University of Basel, Basel, Switzerland
| | | |
Collapse
|