1
|
Perl JR, Crabtree-Beach T, Olyaei A, Hedges M, Jordan BK, Scottoline B. Reducing umbilical catheter migration rates by using a novel securement device. J Perinatol 2024:10.1038/s41372-024-01943-1. [PMID: 38521880 DOI: 10.1038/s41372-024-01943-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 03/13/2024] [Accepted: 03/15/2024] [Indexed: 03/25/2024]
Abstract
OBJECTIVE This study evaluates the effectiveness of a novel device, LifeBubble, in reducing umbilical cord catheter (UC) migration and associated complications in neonates. STUDY DESIGN A retrospective review was performed at Oregon Health & Science University's NICU (2019-2021) to compare standard adhesive securement with LifeBubble. The primary outcomes were UC migration, discontinuation due to malposition, and CLABSI incidence. Differences between groups were statistically analyzed and logistic regression used to adjust for potential confounders. RESULTS Among 118 neonates (57 LifeBubble, 61 adhesive), LifeBubble significantly reduced migration of any UC > 1 vertebral body (12.3% vs. 55.7%), including UVC migration (5.3% vs. 39.3%) and UAC migration (7.0% vs 23.0%), as well as UVC discontinuation due to malposition (5.6% vs 37.7%). The number needed to treat (NNT) to prevent one instance of UVC discontinuation is 4. CONCLUSION LifeBubble effectively reduces UC migration and premature discontinuation, indicating its potential to enhance neonatal care and safety.
Collapse
Affiliation(s)
- Juliana R Perl
- Stanford Byers Center for Biodesign, Stanford University, Stanford, CA, 94305, USA
| | - Tanya Crabtree-Beach
- Division of Neonatology, Department of Pediatrics, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Amy Olyaei
- Division of Neonatology, Department of Pediatrics, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Madeline Hedges
- Division of Neonatology, Department of Pediatrics, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Brian K Jordan
- Division of Neonatology, Department of Pediatrics, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Brian Scottoline
- Division of Neonatology, Department of Pediatrics, Oregon Health & Science University, Portland, OR, 97239, USA.
| |
Collapse
|
2
|
Koppitz J, Ascherl RG, Thome UH, Pulzer F. Incorporating anti-infective drugs into peripherally inserted catheters does not reduce infection rates in neonates. Front Pediatr 2024; 11:1255492. [PMID: 38250594 PMCID: PMC10796449 DOI: 10.3389/fped.2023.1255492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 11/29/2023] [Indexed: 01/23/2024] Open
Abstract
Purpose This study assesses whether peripherally inserted central venous catheters (PICC), impregnated with anti-infective drugs, reduce the rate of infections in neonates compared with unimpregnated catheters. Methods A retrospective analysis was conducted on electronic patient records of neonates born between August 2014 and May 2020, who had PICCs inserted, either standard (S-PICC) or with anti-infective drugs (A-PICC). Catheter-related bloodstream infections (CRBSI) were diagnosed based on clinical symptoms, laboratory results, and mentioning of infection in the patient record. Data on dwell time, mechanical ventilation, insertion site, maximum C-reactive protein (CRP) concentration, and anti-infective drug use were analyzed. Results A total of 223 PICCs were included. The infection rates were A-PICC (18.9%) and S-PICC (12.5%), which were not significantly different (p = 0.257). A-PICCs had significantly longer dwell times than S-PICCs (median 372 vs. 219 h, p = 0.004). The time to infection was not different between the groups (p = 0.3). There were also no significant differences in maximum CRP, insertion site abnormalities, or anti-infective drug use between the groups. Conclusion This retrospective study did not find a significant reduction in infection rates by using PICCs containing anti-infective drugs in neonates. Current antibiotic impregnations do not seem to be effective in preventing blood stream infections.
Collapse
Affiliation(s)
- Julia Koppitz
- Neonatologie, Universitätsklinikum Leipzig, Leipzig, Germany
- Kinder- und Jugendklinik, Universitätsmedizin Rostock, Rostock, Germany
| | | | | | | |
Collapse
|
3
|
Zheng X, He D, Yang Z, Chen L, Jiang M, Qi Y, Qin F, Yu J, Peng Y, Liu L, Hei M. Dwell time and bloodstream infection incidence of umbilical venous catheterization in China. Pediatr Investig 2023; 7:239-246. [PMID: 38050540 PMCID: PMC10693663 DOI: 10.1002/ped4.12403] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 09/21/2023] [Indexed: 12/06/2023] Open
Abstract
Importance Central line-associated bloodstream infection (CLABSI) is one of the most serious complications of central venous access devices. Reducing the risk of CLABSI is of utmost significance in efforts to improve neonatal mortality rates and enhance long-term prognosis. Objective To determine the dwell time and incidence of CLABSI of umbilical venous catheterization (UVC) for preterm infants in China. Methods Preterm infants with UVC admitted to 44 tertiary neonatal intensive care units in 24 provinces in China were enrolled. Study period was from November 2019 to August 2021. The end point of observations was 48 h after umbilical venous (UV) catheter removal. The primary outcomes were dwell time of UV catheter and UVC-associated CLABSI. Data between infants with UV catheter dwell time ≤7 days and >7 days, and with birth weight (BW) ≤1000 g and >1000 g were compared. Results In total, 2172 neonates were enrolled (gestational age 30.0 ± 2.4 weeks, BW 1258.5 ± 392.8 g). The median UV catheter dwell time was 7 (6-10) days. The incidence of UVC-associated CLABSI was 3.03/1000 UV catheter days. For infants with UV catheter dwell time ≤7 days and >7 days, the UVC-associated CLABSI incidence was 3.71 and 2.65 per 1000 UV catheter days, respectively, P = 0.23. For infants with UVC dwell times of 3-6, 7-12, and 13-15 days, the UVC-associated CLABSI rates were 0.14%, 0.68%, and 2.48% (P < 0.01). The Kaplan-Meier plot of UV catheter dwell time to CLABSI showed no difference between infants with BW ≤1000 g and >1000 g (P = 0.60). Interpretation The median dwell time of UV catheter was 7 days, and the incidence of UVC-associated CLABSI was 3.03/1000 catheter days in China. The daily risk of UVC-associated CLABSI and other complications increased with the dwell time.
Collapse
Affiliation(s)
- Xu Zheng
- Neonatal Center, Beijing Children's Hospital, Capital Medical UniversityNational Center of Children's HealthBeijingChina
| | - Dan He
- Guiyang Maternal and Child Health Care HospitalGuiyang Children's HospitalGuizhouChina
| | - Zixin Yang
- Neonatal Center, Beijing Children's Hospital, Capital Medical UniversityNational Center of Children's HealthBeijingChina
| | - Lu Chen
- Neonatal Center, Beijing Children's Hospital, Capital Medical UniversityNational Center of Children's HealthBeijingChina
| | - Min Jiang
- Neonatal Center, Beijing Children's Hospital, Capital Medical UniversityNational Center of Children's HealthBeijingChina
| | - Yujie Qi
- Neonatal Center, Beijing Children's Hospital, Capital Medical UniversityNational Center of Children's HealthBeijingChina
| | - Fei Qin
- Neonatal Center, Beijing Children's Hospital, Capital Medical UniversityNational Center of Children's HealthBeijingChina
| | - Jie Yu
- Neonatal Center, Beijing Children's Hospital, Capital Medical UniversityNational Center of Children's HealthBeijingChina
| | - Yaguang Peng
- Center for Clinical Epidemiology and Evidence‐based Medicine, Beijing Children's Hospital, Capital Medical UniversityNational Center for Children's HealthBeijingChina
| | - Ling Liu
- Guiyang Maternal and Child Health Care HospitalGuiyang Children's HospitalGuizhouChina
| | - Mingyan Hei
- Neonatal Center, Beijing Children's Hospital, Capital Medical UniversityNational Center of Children's HealthBeijingChina
- Key Laboratory of Major Diseases in ChildrenMinistry of EducationBeijingChina
| |
Collapse
|
4
|
Salimi-Jazi F, Wood L, Rafeeqi T, Yamada N, Fuerch J, Wall J. Novel Umbilical Catheter Securement and Protection Device for Umbilical Line Securement during Laparotomy. Am J Perinatol 2023. [PMID: 37758205 DOI: 10.1055/a-2182-4221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
OBJECTIVE Umbilical catheter malposition rate is high. We compared a Novel Umbilical Securement Device (NUSD) to standard methodologies for neonatal invasive care unit patients undergoing laparotomy. STUDY DESIGN Retrospective study was performed on infants undergoing laparotomy from April 2019 to January 2023. Two neonatologists compared position of umbilical arterial catheter/umbilical venous catheter (UVC) on perioperative chest X-ray (CXRs) in patients with or without NUSD. RESULTS Eighteen patients underwent laparotomy, of which 8 patients had NUSD (9 lines) and 10 patients did not (14 lines). In NUSD group, mean gestational age was 37 ± 4 weeks and mean birth weight was 2.3 ± 0.9 kg compared with 31 ± 8 weeks and 2.1 ± 1.4 kg in non-NUSD group, respectively. The mean age at surgery was 5 ± 7 and 5 ± 3 days, respectively. No malposition was seen in NUSD group, while 57% of UVCs (28% of lines) were malpositioned postoperatively in non-NUSD group (p = 0.048). CONCLUSION NUSD is an umbilical catheter securement device with low malposition rate, specifically during perioperative period with heightened risk for dislodgement. KEY POINTS · Umbilical catheters provide reliable access for neonates but have a high rate of malpositioning.. · NUSD is an umbilical catheter securement device with low malposition rate.. · NUSD can be kept in place during laparotomy and can decrease the risk of malpositioning..
Collapse
Affiliation(s)
- Fereshteh Salimi-Jazi
- Division of Pediatric Surgery, Department of Surgery, Stanford University, California
| | - Lauren Wood
- Division of Pediatric Surgery, Department of Surgery, Stanford University, California
| | - Talha Rafeeqi
- Division of Pediatric Surgery, Department of Surgery, Stanford University, California
| | - Nicole Yamada
- Division of Neonatal and Developmental Medicine, Department of Pediatrics, Stanford University, California
| | - Janene Fuerch
- Division of Neonatal and Developmental Medicine, Department of Pediatrics, Stanford University, California
| | - James Wall
- Division of Pediatric Surgery, Department of Surgery, Stanford University, California
| |
Collapse
|
5
|
Barone G, D'Andrea V, Ancora G, Cresi F, Maggio L, Capasso A, Mastroianni R, Pozzi N, Rodriguez-Perez C, Romitti MG, Tota F, Spagnuolo F, Raimondi F, Pittiruti M. The neonatal DAV-expert algorithm: a GAVeCeLT/GAVePed consensus for the choice of the most appropriate venous access in newborns. Eur J Pediatr 2023; 182:3385-3395. [PMID: 37195350 DOI: 10.1007/s00431-023-04984-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 04/11/2023] [Accepted: 04/15/2023] [Indexed: 05/18/2023]
Abstract
In most NICUs, the choice of the venous access device currently relies upon the operator's experience and preferences. However, considering the high failure rate of vascular devices in the neonatal population, such clinical choice has a critical relevance and should preferably be based on the best available evidence. Though some algorithms have been published over the last 5 years, none of them seems in line with the current scientific evidence. Thus, the GAVePed-which is the pediatric interest group of the most important Italian group on venous access, GAVeCeLT-has developed a national consensus about the choice of the venous access device in the neonatal population. After a systematic review of the available evidence, the panel of the consensus (which included Italian neonatologists specifically experts in this area) has provided structured recommendations answering four sets of questions regarding (1) umbilical venous catheters, (2) peripheral cannulas, (3) epicutaneo-cava catheters, and (4) ultrasound-guided centrally and femorally inserted central catheters. Only statements reaching a complete agreement were included in the final recommendations. All recommendations were also structured as a simple visual algorithm, so as to be easily translated into clinical practice. Conclusion: The goal of the present consensus is to offer a systematic set of recommendations on the choice of the most appropriate vascular access device in Neonatal Intensive Care Unit.
Collapse
Affiliation(s)
- Giovanni Barone
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL Della Romagna, Viale Settembrini 2, Rimini, Italy.
| | - Vito D'Andrea
- Neonatal Intensive Care Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Gina Ancora
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL Della Romagna, Viale Settembrini 2, Rimini, Italy
| | - Francesco Cresi
- Neonatology and Neonatal Intensive Care Unit, Sant'Anna Hospital, University of Turin, Città Della Salute E Della Scienza, Turin, Italy
| | - Luca Maggio
- Neonatology and Neonatal Intensive Care Unit, AO San Camillo Forlanini, Rome, Italy
| | - Antonella Capasso
- Neonatology and Neonatal Intensive Care Unit, A.O.U. Federico 2, Naples, Italy
| | | | - Nicola Pozzi
- Neonatal Intensive Care Unit, San Pio Hospital, Benevento, Italy
| | - Carmen Rodriguez-Perez
- Neonatology and Neonatal Intensive Care Unit, ASST Spedali Civili, Ospedale Dei Bambini, Brescia, Italy
| | | | - Francesca Tota
- Neonatal Intensive Care Unit, Ospedale S. Chiara, APSS, Trento, Italy
| | - Ferdinando Spagnuolo
- Neonatal Intensive Care Unit, AOU Università Degli Studi Della Campania "Luigi Vanvitelli", Naples, Italy
| | - Francesco Raimondi
- Neonatology and Neonatal Intensive Care Unit, A.O.U. Federico 2, Naples, Italy
| | - Mauro Pittiruti
- Department of Surgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| |
Collapse
|
6
|
Yu Z, Hu X, Xu X, Lin L, Gu Y, Zhou J. A nurse-inserted peripherally inserted central catheter program in general pediatrics: a single-center experience. BMC Pediatr 2023; 23:21. [PMID: 36639748 PMCID: PMC9840319 DOI: 10.1186/s12887-022-03809-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Accepted: 12/16/2022] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND A peripherally inserted central catheter (PICC) with its tip preferably in the vena cava is essential in caring for patients with chronic conditions in general pediatrics. However, PICC-related complications are concerning and warrant further investigations. OBJECTIVES To share the experience of a nurse-inserted peripherally inserted central catheters (PICC) program initiated in a general pediatric department. METHODS A retrospective descriptive cohort study based on a prospectively collected database was conducted. All PICCs inserted in the departments of gastroenterology and pulmonology in a tertiary pediatric center from Dec. 2015 to Dec. 2019 were included in the study. Complications and risk factors were analyzed by comparing cases with and without complications. We also reported arm movements in correcting mal-positioned newly-inserted PICCs. RESULTS There were 169 cases with a median (IQR) age of 42(6, 108) months who received PICC insertion during a 4-year period. Inflammatory bowel disease was the leading diagnosis accounting for 25.4% (43/169) of all cases. The overall complication rate was 16.4 per 1000 catheter days with malposition and occlusion as the two most common complications. Multivariate models performed by logistic regression demonstrated that young age [p = 0.004, OR (95%CI) = 0.987(0.978, 0.996)] and small PICC diameter (1.9Fr, p = 0.003, OR (95%CI) = 3.936(1.578, 9.818)] were risk factors for PICC complications. Correction of malpositioned catheters was attempted and all succeeded in 9 eligible cases by using arm movements. CONCLUSION The nurse-inserted PICC program in general pediatrics is feasible with a low rate of complications. PICC tip malposition and occlusion were two major PICC-related complications when low age and small catheter lumina were major risk factors. Furtherly, arm manipulation potentially is an easy and effective approach for correcting malpositioned newly-inserted PICC catheters.
Collapse
Affiliation(s)
- Zhuowen Yu
- grid.411333.70000 0004 0407 2968Department of Gastroenterology and Pulmonology, Children’s Hospital of Fudan University, Shanghai, China
| | - Xiaojing Hu
- grid.411333.70000 0004 0407 2968Nursing department office, Children’s Hospital of Fudan University, Shanghai, China
| | - Xiaofeng Xu
- grid.411333.70000 0004 0407 2968Department of Gastroenterology and Pulmonology, Children’s Hospital of Fudan University, Shanghai, China
| | - Lili Lin
- grid.411333.70000 0004 0407 2968Department of Gastroenterology and Pulmonology, Children’s Hospital of Fudan University, Shanghai, China
| | - Ying Gu
- grid.411333.70000 0004 0407 2968Nursing department office, Children’s Hospital of Fudan University, Shanghai, China
| | - Jianguo Zhou
- grid.411333.70000 0004 0407 2968Department of Neonatology, Children’s Hospital of Fudan University, Shanghai, China
| |
Collapse
|
7
|
Infectious Risks Related to Umbilical Venous Catheter Dwell Time and Its Replacement in Newborns: A Narrative Review of Current Evidence. LIFE (BASEL, SWITZERLAND) 2022; 13:life13010123. [PMID: 36676072 PMCID: PMC9863057 DOI: 10.3390/life13010123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/27/2022] [Accepted: 12/28/2022] [Indexed: 01/03/2023]
Abstract
The use of umbilical venous catheters (UVCs) has become the standard of care in the neonatal intensive care unit (NICU) to administer fluids, medications and parenteral nutrition. However, it is well known that UVCs can lead to some serious complications, both mechanical and infective, including CLABSI (Central Line-Associated Bloodstream Infections). Most authors recommend removing UVC within a maximum of 14 days from its placement. However, the last Infusion Therapy Standards of Practice (INS) guidelines recommends limiting the UVC dwell time to 7 to 10 days, to reduce risks of infectious and thrombotic complications. These guidelines also suggest as an infection prevention strategy to remove UVC after 4 days, followed by the insertion of a PICC if a central line is still needed. Nevertheless, the maximum UVC dwell time to reduce the risk of CLABSI is still controversial, as well as the time of its replacement with a PICC. In this study we reviewed a total of 177 articles, found by using the PubMed database with the following search strings: "UVC AND neonates", "(neonate* OR newborn*) AND (UVC OR central catheter*) AND (infection*)". We also analyze the INS guidelines to provide the reader an updated overview on this topic. The purpose of this review is to give updated information on CVCs infectious risks by examining the literature in this field. These data could help clinicians in deciding the best time to remove or to replace the UVC with a PICC, to reduce CLABSIs risk. Despite the lack of strong evidence, the risk of CLABSI seems to be minimized when UVC is removed/replaced within 7 days from insertion and this indication is emerging from more recent and larger studies.
Collapse
|
8
|
Gibson K, Sharp R, Ullman A, Morris S, Kleidon T, Esterman A. Adverse events associated with umbilical catheters: a systematic review and meta-analysis. J Perinatol 2021; 41:2505-2512. [PMID: 34272469 DOI: 10.1038/s41372-021-01147-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 06/11/2021] [Accepted: 06/30/2021] [Indexed: 02/06/2023]
Abstract
OBJECTIVE To determine the incidence of adverse events (AEs) associated with umbilical catheters in the neonatal population. STUDY DESIGN Systematic review and meta-analysis of observational studies and randomized controlled trials published between 2010 and 2020. RESULTS In total 14,226 umbilical venous catheters (UVCs) and 4228 umbilical arterial catheters (UACs) were included. Overall, 13.4% of UVCs were associated with an AE (95% CI: 10.1-17.0) or 2.4 per 1000 catheter days (95% CI: 1.8-3.0). UACs had an AE rate of 9% (95% CI: 5.9-12.8) or 0.87 per 1000 catheter days (95% CI: 0.4-1.3). UVC malposition was the most common (41.7% [95% CI: 27.6-56.5]). Local injury from UAC taping was the most common AE in one study. CONCLUSIONS Umbilical catheters have a high incidence of AEs. Research into accurate methods of tip verification, tip surveillance, and securement is required.
Collapse
Affiliation(s)
- Kim Gibson
- Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia.
| | - Rebecca Sharp
- Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia
| | - Amanda Ullman
- Children's Health Queensland and Health Service, Centre of Children's Health Research, South Brisbane, QLD, Australia.,School of Nursing, Midwifery and Social Work, The University of Queensland, Brisbane, QLD, Australia
| | - Scott Morris
- Neonatal Unit, Flinders Medical Centre, Bedford Park, SA, Australia.,College of Medicine and Public Health, Flinders University, Adelaide, Australia
| | - Tricia Kleidon
- Queensland Children's Hospital, South Brisbane, QLD, Australia
| | - Adrian Esterman
- Clinical and Health Sciences, Rosemary Bryant AO Research Centre, University of South Australia, Adelaide, SA, Australia
| |
Collapse
|
9
|
Gibson K, Sharp R, Ullman A, Morris S, Kleidon T, Esterman A. Risk factors for umbilical vascular catheter-related adverse events: A scoping review. Aust Crit Care 2021; 35:89-101. [PMID: 34088575 DOI: 10.1016/j.aucc.2021.02.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 02/24/2021] [Accepted: 02/28/2021] [Indexed: 02/07/2023] Open
Abstract
INTRODUCTION Adverse events associated with umbilical catheters include malposition, bloodstream infections, thrombosis, tip migration, and extravasation, resulting in loss of vascular access and increased risk of morbidity and mortality. There is a need for greater understanding of risk factors associated with adverse events to inform safe practice. OBJECTIVES The aim of the study was to summarise the existing evidence regarding risk factors for umbilical catheter-related adverse events to inform the undertaking of future research. REVIEW METHOD USED A scoping review of peer-reviewed original research and theses was performed. DATA SOURCES The US National Library of Medicine National Institutes of Health, Embase, EMcare, and ProQuest Dissertations and Theses were the data sources. REVIEW METHODS Informed by the Joanna Briggs Institute Reviewer's Manual, all types of original research studies reporting adverse events published in English from 2009 to 2020 were eligible for inclusion. Studies where umbilical artery catheter and umbilical venous catheter data could not be extracted separately were excluded. RESULTS Searching identified 1954 publications and theses, 1533 were excluded at screening, and 418 were assessed for eligibility at full text. A total of 89 studies met the inclusion criteria. A range of potential risk factors for umbilical arterial and venous catheters were identified. Longer dwell time and prematurity were associated with increased risk of bloodstream infection and thrombosis in cohort studies. Case studies detailed analogous factors such as insertion techniques and lack of catheter surveillance during dwell warrant further investigation. CONCLUSIONS We identified a vast range of patient, device, and provider risk factors that warrant further investigation. There was a lack of large cohort studies and randomised controlled trials to demonstrate the significance of these risk factors. Improvement in methods to ensure correct catheter tip location and to detect adverse events early is essential. In addition, policy needs to be developed to guide clinicians in catheter surveillance measures to reduce the risk of adverse events.
Collapse
Affiliation(s)
- Kim Gibson
- Clinical and Health Sciences, University of South Australia, PO Box 2471, South Australia, 5000, Australia.
| | - Rebecca Sharp
- Clinical and Health Sciences, University of South Australia, PO Box 2471, South Australia, 5000, Australia.
| | - Amanda Ullman
- School of Nursing and Midwifery, Menzies Health Institute Queensland, Nathan Campus, 170 Kessels Road Queensland 4111, Australia; Children's Health Queensland and Health Service Centre of Children's Health Research, South Brisbane QLD 4101, Australia; School of Nursing, Midwifery and Social Work The University of Queensland, Brisbane QLD 4072, Australia.
| | - Scott Morris
- College of Medicine and Public Health, Flinders University, Neonatal Unit, Flinders Medical Centre, Bedford Drive, Bedford Park, South Australia 5042, Australia.
| | - Tricia Kleidon
- Queensland Children's Hospital, 401 Stanley Street, South Brisbane, Q. 4101, Australia; School of Nursing and Midwifery, Griffith University, 170 Kessels Raod, Nathan, Q. 4111, Australia.
| | - Adrian Esterman
- Clinical and Health Sciences, University of South Australia, PO Box 2471, South Australia, 5000, Australia.
| |
Collapse
|
10
|
Never judge a book by its cover: how NICU evaluators reach conclusions about quality of care. J Perinatol 2018; 38:751-758. [PMID: 29593356 DOI: 10.1038/s41372-018-0092-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 02/14/2018] [Accepted: 02/20/2018] [Indexed: 11/09/2022]
Abstract
OBJECTIVE To identify key features in the NICU care delivery context that influence quality of care delivery. STUDY DESIGN Qualitative study using in-depth, semi-structured interviews with 10 NICU quality experts with extensive experience conducting NICU site visits and evaluating quality of care. Analyses were performed using the method of constant comparison based on grounded theory. RESULTS Qualitative analysis yielded three major themes: (1) the foundation for high quality care is a cohesive unit culture, characterized by open communication, teamwork, and engagement of families; (2) effective linkages between measurement and improvement action is necessary for continuous improvement; and (3) NICU capacity for improvement is sustained by active support, exchange of skills, and resources from the hospital. CONCLUSIONS Team cohesion, engagement of families, culture of improvement supported by measurement and institutional support from the hospital are some of the key contextual and managerial features critical to high-quality NICU care.
Collapse
|