1
|
Xu Z, Palm ML, Huxter W, Herb K, Abendroth JM, Bouzehouane K, Boulle O, Gabor MS, Urrestarazu Larranaga J, Morales A, Rhensius J, Puebla-Hellmann G, Degen CL. Minimizing Sensor-Sample Distances in Scanning Nitrogen-Vacancy Magnetometry. ACS NANO 2025; 19:8255-8265. [PMID: 39983234 PMCID: PMC11887488 DOI: 10.1021/acsnano.4c18460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2024] [Revised: 02/06/2025] [Accepted: 02/07/2025] [Indexed: 02/23/2025]
Abstract
Scanning magnetometry with nitrogen-vacancy (NV) centers in diamond has led to significant advances in the sensitive imaging of magnetic systems. The spatial resolution of the technique, however, remains limited to tens to hundreds of nanometers, even for probes where NV centers are engineered within 10 nm from the tip apex. Here, we present a correlated investigation of the crucial parameters that determine the spatial resolution: the mechanical and magnetic stand-off distances, as well as the subsurface NV center depth in diamond. We study their contributions using mechanical approach curves, photoluminescence measurements, magnetometry scans, and nuclear magnetic resonance (NMR) spectroscopy of surface adsorbates. We first show that the stand-off distance is mainly limited by features on the surface of the diamond tip, hindering mechanical access. Next, we demonstrate that frequency-modulated (FM) atomic force microscopy feedback partially overcomes this issue, leading to closer and more consistent magnetic stand-off distances (26-87 nm) compared with the more common amplitude-modulated feedback (43-128 nm). FM operation thus permits improved magnetic imaging of sub-100-nm spin textures, shown for the spin cycloid in BiFeO3 and domain walls in a CoFeB synthetic antiferromagnet. Finally, by examining 1H and 19F NMR signals in soft contact with a polytetrafluoroethylene surface, we demonstrate a minimum NV-to-sample distance of 7.9 ± 0.4 nm.
Collapse
Affiliation(s)
- Zhewen Xu
- Department
of Physics, ETH Zürich, Otto Stern Weg 1, 8093 Zürich, Switzerland
- QZabre
AG, Neubrunnenstrasse
50, 8050 Zürich, Switzerland
| | - Marius L. Palm
- Department
of Physics, ETH Zürich, Otto Stern Weg 1, 8093 Zürich, Switzerland
| | - William Huxter
- Department
of Physics, ETH Zürich, Otto Stern Weg 1, 8093 Zürich, Switzerland
| | - Konstantin Herb
- Department
of Physics, ETH Zürich, Otto Stern Weg 1, 8093 Zürich, Switzerland
| | - John M. Abendroth
- Department
of Physics, ETH Zürich, Otto Stern Weg 1, 8093 Zürich, Switzerland
| | - Karim Bouzehouane
- Laboratoire
Albert Fert, CNRS, Thales, Université
Paris-Saclay, 91767 Palaiseau, France
| | - Olivier Boulle
- Université
Grenoble Alpes, CNRS, CEA, SPINTEC, 38054 Grenoble, France
| | - Mihai S. Gabor
- Technical
University of Cluj-Napoca, Memorandumului 28, Cluj-Napoca 400347, Romania
| | | | - Andrea Morales
- QZabre
AG, Neubrunnenstrasse
50, 8050 Zürich, Switzerland
| | - Jan Rhensius
- QZabre
AG, Neubrunnenstrasse
50, 8050 Zürich, Switzerland
| | | | - Christian L. Degen
- Department
of Physics, ETH Zürich, Otto Stern Weg 1, 8093 Zürich, Switzerland
- Quantum
Center, ETH Zürich, 8093 Zürich, Switzerland
| |
Collapse
|
2
|
Nguyen PT, Le TK, Nguyen HQ, Ho LB. Harnessing graph state resources for robust quantum magnetometry under noise. Sci Rep 2024; 14:20528. [PMID: 39227686 PMCID: PMC11371932 DOI: 10.1038/s41598-024-71365-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 08/26/2024] [Indexed: 09/05/2024] Open
Abstract
Precise measurement of magnetic fields is essential for various applications, such as fundamental physics, space exploration, and biophysics. Although recent progress in quantum engineering has assisted in creating advanced quantum magnetometers, there are still ongoing challenges in improving their efficiency and noise resistance. This study focuses on using symmetric graph state resources for quantum magnetometry to enhance measurement precision by analyzing the estimation theory under time-homogeneous and time-inhomogeneous noise models. The results show a significant improvement in estimating both single and multiple Larmor frequencies. In single Larmor frequency estimation, the quantum Fisher information spans a spectrum from the standard quantum limit to the Heisenberg limit within a periodic range of the Larmor frequency, and in the case of multiple Larmor frequencies, it can exceed the standard quantum limit for both noisy cases. This study highlights the potential of graph state-based methods for improving magnetic field measurements under noisy environments.
Collapse
Affiliation(s)
- Phu Trong Nguyen
- Department of Advanced Material Science and Nanotechnology, University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, Hanoi, 11307, Vietnam
| | - Trung Kien Le
- Department of Physics, University of California, Santa Barbara, Santa Barbara, USA
- Department of Applied Physics, Stanford University, Stanford, USA
| | - Hung Q Nguyen
- Nano and Energy Center, University of Science, Vietnam National University, Hanoi, 120401, Vietnam
| | - Le Bin Ho
- Frontier Research Institute for Interdisciplinary Sciences, Tohoku University, Sendai, 980-8578, Japan.
- Department of Applied Physics, Graduate School of Engineering, Tohoku University, Sendai, 980-8579, Japan.
| |
Collapse
|
3
|
Bian K, Zheng W, Chen X, Zhang S, Stöhr R, Denisenko A, Yang S, Wrachtrup J, Jiang Y. A scanning probe microscope compatible with quantum sensing at ambient conditions. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:053707. [PMID: 38819258 DOI: 10.1063/5.0202756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 05/08/2024] [Indexed: 06/01/2024]
Abstract
We designed and built up a new type of ambient scanning probe microscope (SPM), which is fully compatible with state-of-the-art quantum sensing technology based on the nitrogen-vacancy (NV) centers in diamond. We chose a qPlus-type tuning fork (Q up to ∼4400) as the current/force sensor of SPM for its high stiffness and stability under various environments, which yields atomic resolution under scanning tunneling microscopy mode and 1.2-nm resolution under atomic force microscopy mode. The tip of SPM can be used to directly image the topography of nanoscale targets on diamond surfaces for quantum sensing and to manipulate the electrostatic environment of NV centers to enhance their sensitivity up to a single proton spin. In addition, we also demonstrated scanning magnetometry and electrometry with a spatial resolution of ∼20 nm. Our new system not only paves the way for integrating atomic/molecular-scale color-center qubits onto SPM tips to produce quantum tips but also provides the possibility of fabricating color-center qubits with nanoscale or atomic precision.
Collapse
Affiliation(s)
- Ke Bian
- International Center for Quantum Materials, School of Physics, Peking University, Beijing 100871, China
| | - Wentian Zheng
- International Center for Quantum Materials, School of Physics, Peking University, Beijing 100871, China
| | - Xiakun Chen
- International Center for Quantum Materials, School of Physics, Peking University, Beijing 100871, China
| | - Shichen Zhang
- International Center for Quantum Materials, School of Physics, Peking University, Beijing 100871, China
| | - Rainer Stöhr
- Third Institute of Physics, University of Stuttgart and Institute for Quantum Science and Technology (IQST), Stuttgart 70569, Germany
- Max Planck Institute for Solid State Research, Stuttgart 70569, Germany
| | - Andrej Denisenko
- Third Institute of Physics, University of Stuttgart and Institute for Quantum Science and Technology (IQST), Stuttgart 70569, Germany
- Max Planck Institute for Solid State Research, Stuttgart 70569, Germany
| | - Sen Yang
- Department of Physics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong 999077, China
| | - Jörg Wrachtrup
- Third Institute of Physics, University of Stuttgart and Institute for Quantum Science and Technology (IQST), Stuttgart 70569, Germany
- Max Planck Institute for Solid State Research, Stuttgart 70569, Germany
| | - Ying Jiang
- International Center for Quantum Materials, School of Physics, Peking University, Beijing 100871, China
- Collaborative Innovation Center of Quantum Matter, Beijing 100871, China
- Interdisciplinary Institute of Light-Element Quantum Materials and Research Center for Light-Element Advanced Materials, Peking University, Beijing 100871, China
- New Cornerstone Science Laboratory, Peking University, Beijing 100871, China
| |
Collapse
|
4
|
Liang K, Zhu M, Qin X, Meng Z, Wang P, Du J. Field-programmable-gate-array based hardware platform for nitrogen-vacancy center based fast magnetic imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:024701. [PMID: 38341725 DOI: 10.1063/5.0187228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 01/18/2024] [Indexed: 02/13/2024]
Abstract
A nitrogen-vacancy center based scanning magnetic microscope can be used to characterize magnetics at the nanoscale with high sensitivity. This paper reports a field-programmable-gate-array based hardware system that is designed to realize control and signal readout for fast scanning magnetic imaging with a nitrogen-vacancy center. A 10-channel 1 Msps @ 20 bit analog signal generator, a 12-channel 50 ps resolution pulse generator, a 300 Msps @ 16 bit lock-in amplifier with proportional integral derivative control function, and a 4-channel 200 Msps counter are integrated on the platform. A customized acceleration algorithm is realized with the re-configurable field-programmable-gate-array chip to accelerate the imaging speed of the nitrogen-vacancy system, and the experimental results prove that the imaging efficiency can be accelerated by five times compared to the system without the acceleration algorithm. The platform has considerable potential for future applications of fast scanning magnetic imaging.
Collapse
Affiliation(s)
- Kaiqing Liang
- CAS Key Laboratory of Microscale Magnetic Resonance and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China
- CAS Center for Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, China
- Hefei National Laboratory, University of Science and Technology of China, Hefei 230088, China
| | - Mingdong Zhu
- CAS Key Laboratory of Microscale Magnetic Resonance and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China
- CAS Center for Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, China
- Hefei National Laboratory, University of Science and Technology of China, Hefei 230088, China
| | - Xi Qin
- CAS Key Laboratory of Microscale Magnetic Resonance and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China
- CAS Center for Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, China
- Hefei National Laboratory, University of Science and Technology of China, Hefei 230088, China
| | - Ziqing Meng
- CAS Key Laboratory of Microscale Magnetic Resonance and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China
- CAS Center for Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, China
- Hefei National Laboratory, University of Science and Technology of China, Hefei 230088, China
| | - Pengfei Wang
- CAS Key Laboratory of Microscale Magnetic Resonance and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China
- CAS Center for Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, China
- Hefei National Laboratory, University of Science and Technology of China, Hefei 230088, China
| | - Jiangfeng Du
- CAS Key Laboratory of Microscale Magnetic Resonance and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China
- CAS Center for Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, China
- Hefei National Laboratory, University of Science and Technology of China, Hefei 230088, China
- Institute of Quantum Sensing and School of Physics, Zhejiang University, Hangzhou 310027, China
| |
Collapse
|
5
|
da Cruz AR, Flatté ME. Dissipationless Circulating Currents and Fringe Magnetic Fields Near a Single Spin Embedded in a Two-Dimensional Electron Gas. PHYSICAL REVIEW LETTERS 2023; 131:086301. [PMID: 37683147 DOI: 10.1103/physrevlett.131.086301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 02/21/2023] [Accepted: 05/26/2023] [Indexed: 09/10/2023]
Abstract
Theoretical calculations predict the anisotropic dissipationless circulating current induced by a spin defect in a two-dimensional electron gas. The shape and spatial extent of these dissipationless circulating currents depend dramatically on the relative strengths of spin-orbit fields with differing spatial symmetry, offering the potential to use an electric gate to manipulate nanoscale magnetic fields and couple magnetic defects. The spatial structure of the magnetic field produced by this current is calculated and provides a direct way to measure the spin-orbit fields of the host, as well as the defect spin orientation, e.g., through scanning nanoscale magnetometry.
Collapse
Affiliation(s)
- Adonai R da Cruz
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
| | - Michael E Flatté
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
- Department of Physics and Astronomy, University of Iowa, Iowa City, Iowa 52242, USA
| |
Collapse
|
6
|
Huxter WS, Sarott MF, Trassin M, Degen CL. Imaging ferroelectric domains with a single-spin scanning quantum sensor. NATURE PHYSICS 2023; 19:644-648. [PMID: 37205126 PMCID: PMC10185469 DOI: 10.1038/s41567-022-01921-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 12/14/2022] [Indexed: 05/21/2023]
Abstract
The ability to sensitively image electric fields is important for understanding many nanoelectronic phenomena, including charge accumulation at surfaces1 and interfaces2 and field distributions in active electronic devices3. A particularly exciting application is the visualization of domain patterns in ferroelectric and nanoferroic materials4,5, owing to their potential in computing and data storage6-8. Here, we use a scanning nitrogen-vacancy (NV) microscope, well known for its use in magnetometry9, to image domain patterns in piezoelectric (Pb[Zr0.2Ti0.8]O3) and improper ferroelectric (YMnO3) materials through their electric fields. Electric field detection is enabled by measuring the Stark shift of the NV spin10,11 using a gradiometric detection scheme12. Analysis of the electric field maps allows us to discriminate between different types of surface charge distributions, as well as to reconstruct maps of the three-dimensional electric field vector and charge density. The ability to measure both stray electric and magnetic fields9,13 under ambient conditions opens opportunities for the study of multiferroic and multifunctional materials and devices8,14.
Collapse
Affiliation(s)
| | | | - Morgan Trassin
- Department of Materials, ETH Zurich, Zurich, Switzerland
| | - Christian L. Degen
- Department of Physics, ETH Zurich, Zurich, Switzerland
- Quantum Center, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
7
|
Janitz E, Herb K, Völker LA, Huxter WS, Degen CL, Abendroth JM. Diamond surface engineering for molecular sensing with nitrogen-vacancy centers. JOURNAL OF MATERIALS CHEMISTRY. C 2022; 10:13533-13569. [PMID: 36324301 PMCID: PMC9521415 DOI: 10.1039/d2tc01258h] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 08/06/2022] [Indexed: 05/20/2023]
Abstract
Quantum sensing using optically addressable atomic-scale defects, such as the nitrogen-vacancy (NV) center in diamond, provides new opportunities for sensitive and highly localized characterization of chemical functionality. Notably, near-surface defects facilitate detection of the minute magnetic fields generated by nuclear or electron spins outside of the diamond crystal, such as those in chemisorbed and physisorbed molecules. However, the promise of NV centers is hindered by a severe degradation of critical sensor properties, namely charge stability and spin coherence, near surfaces (< ca. 10 nm deep). Moreover, applications in the chemical sciences require methods for covalent bonding of target molecules to diamond with robust control over density, orientation, and binding configuration. This forward-looking Review provides a survey of the rapidly converging fields of diamond surface science and NV-center physics, highlighting their combined potential for quantum sensing of molecules. We outline the diamond surface properties that are advantageous for NV-sensing applications, and discuss strategies to mitigate deleterious effects while simultaneously providing avenues for chemical attachment. Finally, we present an outlook on emerging applications in which the unprecedented sensitivity and spatial resolution of NV-based sensing could provide unique insight into chemically functionalized surfaces at the single-molecule level.
Collapse
Affiliation(s)
- Erika Janitz
- Department of Physics, ETH Zürich Otto-Stern-Weg 1 8093 Zürich Switzerland
| | - Konstantin Herb
- Department of Physics, ETH Zürich Otto-Stern-Weg 1 8093 Zürich Switzerland
| | - Laura A Völker
- Department of Physics, ETH Zürich Otto-Stern-Weg 1 8093 Zürich Switzerland
| | - William S Huxter
- Department of Physics, ETH Zürich Otto-Stern-Weg 1 8093 Zürich Switzerland
| | - Christian L Degen
- Department of Physics, ETH Zürich Otto-Stern-Weg 1 8093 Zürich Switzerland
| | - John M Abendroth
- Department of Physics, ETH Zürich Otto-Stern-Weg 1 8093 Zürich Switzerland
| |
Collapse
|