1
|
Shen Z, Plouraboué F, Lintuvuori JS, Zhang H, Abbasi M, Misbah C. Anomalous Diffusion of Deformable Particles in a Honeycomb Network. PHYSICAL REVIEW LETTERS 2023; 130:014001. [PMID: 36669217 DOI: 10.1103/physrevlett.130.014001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 03/15/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
Transport of deformable particles in a honeycomb network is studied numerically. It is shown that the particle deformability has a strong impact on their distribution in the network. For sufficiently soft particles, we observe a short memory behavior from one bifurcation to the next, and the overall behavior consists in a random partition of particles, exhibiting a diffusionlike transport. On the contrary, stiff enough particles undergo a biased distribution whereby they follow a deterministic partition at bifurcations, due to long memory. This leads to a lateral ballistic drift in the network at small concentration and anomalous superdiffusion at larger concentration, even though the network is ordered. A further increase of concentration enhances particle-particle interactions which shorten the memory effect, turning the particle anomalous diffusion into a classical diffusion. We expect the drifting and diffusive regime transition to be generic for deformable particles.
Collapse
Affiliation(s)
- Zaiyi Shen
- Université Grenoble Alpes, CNRS, LIPHY, F-38000 Grenoble, France
- Université de Bordeaux, CNRS, LOMA (UMR 5798), F-33405 Talence, France
| | - Franck Plouraboué
- Institut de Mécanique des Fluides de Toulouse, IMFT, Université de Toulouse, CNRS, Toulouse, France
| | - Juho S Lintuvuori
- Université de Bordeaux, CNRS, LOMA (UMR 5798), F-33405 Talence, France
| | - Hengdi Zhang
- Shenzhen Sibionics Co. Ltd., Shenzhen 518000, People's Republic of China
| | - Mehdi Abbasi
- Université Grenoble Alpes, CNRS, LIPHY, F-38000 Grenoble, France
| | - Chaouqi Misbah
- Université Grenoble Alpes, CNRS, LIPHY, F-38000 Grenoble, France
| |
Collapse
|
2
|
Stathoulopoulos A, Passos A, Balabani S. Flows of healthy and hardened RBC suspensions through a micropillar array. Med Eng Phys 2022; 107:103874. [DOI: 10.1016/j.medengphy.2022.103874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 07/29/2022] [Accepted: 08/09/2022] [Indexed: 11/25/2022]
|
3
|
Computational Study of Methods for Determining the Elasticity of Red Blood Cells Using Machine Learning. Symmetry (Basel) 2022. [DOI: 10.3390/sym14081732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
RBC (Red Blood Cell) membrane is a highly elastic structure, and proper modelling of this elasticity is essential for biomedical applications that involve computational experiments with blood flow. In this work, we present a new method for estimating one of the key parameters of red blood cell elasticity, which uses a neural network trained on the simulation outputs. We test classic LSTM (Long-Short Term Memory) architecture for the time series regression task, and we also experiment with novel CNN-LSTM (Convolutional Neural Network) architecture. We paid special attention to investigating the impact of the way the three-dimensional training data are reduced to their two-dimensional projections. Such a comparison is possible thanks to working with simulation outputs that are equivalently defined for all dimensions and their combinations. The obtained results can be used as recommendations for an appropriate way to record real experiments for which the reduced dimension of the acquired data is essential.
Collapse
|
4
|
Alexy T, Detterich J, Connes P, Toth K, Nader E, Kenyeres P, Arriola-Montenegro J, Ulker P, Simmonds MJ. Physical Properties of Blood and their Relationship to Clinical Conditions. Front Physiol 2022; 13:906768. [PMID: 35874542 PMCID: PMC9298661 DOI: 10.3389/fphys.2022.906768] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 06/14/2022] [Indexed: 02/03/2023] Open
Abstract
It has been long known that blood health heavily influences optimal physiological function. Abnormalities affecting the physical properties of blood have been implicated in the pathogenesis of various disorders, although the exact mechanistic links between hemorheology and clinical disease manifestations remain poorly understood. Often overlooked in current medical practice, perhaps due to the promises offered in the molecular and genetic era, the physical properties of blood which remain a valuable and definitive indicator of circulatory health and disease. Bridging this gap, the current manuscript provides an introduction to hemorheology. It reviews the properties that dictate bulk and microcirculatory flow by systematically dissecting the biomechanics that determine the non-Newtonian behavior of blood. Specifically, the impact of hematocrit, the mechanical properties and tendency of red blood cells to aggregate, and various plasma factors on blood viscosity will be examined. Subsequently, the manner in which the physical properties of blood influence hemodynamics in health and disease is discussed. Special attention is given to disorders such as sickle cell disease, emphasizing the clinical impact of severely abnormal blood rheology. This review expands into concepts that are highly topical; the relation between mechanical stress and intracellular homeostasis is examined through a contemporary cell-signaling lens. Indeed, accumulating evidence demonstrates that nitric oxide is not only transported by erythrocytes, but is locally produced by mechanically-sensitive enzymes, which appears to have intracellular and potentially extracellular effects. Finally, given the importance of shear forces in the developing field of mechanical circulatory support, we review the role of blood rheology in temporary and durable mechanical circulatory support devices, an increasingly utilized method of life support. This review thus provides a comprehensive overview for interested trainees, scientists, and clinicians.
Collapse
Affiliation(s)
- Tamas Alexy
- Department of Medicine, Division of Cardiology, University of Minnesota, Minneapolis, MN, United States
| | - Jon Detterich
- Department of Pediatrics, Division of Cardiology, Children's Hospital Los Angeles, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States
| | - Philippe Connes
- Laboratory LIBM EA7424, Vascular Biology and Red Blood Cell Team, University of Lyon, Lyon, France
| | - Kalman Toth
- First Department of Medicine, Division of Cardiology, Medical School, University of Pecs, Pecs, Hungary
| | - Elie Nader
- Laboratory LIBM EA7424, Vascular Biology and Red Blood Cell Team, University of Lyon, Lyon, France
| | - Peter Kenyeres
- First Department of Medicine, Division of Cardiology, Medical School, University of Pecs, Pecs, Hungary
| | - Jose Arriola-Montenegro
- Department of Medicine, Division of Cardiology, University of Minnesota, Minneapolis, MN, United States
| | - Pinar Ulker
- Department of Physiology, Akdeniz University, Faculty of Medicine, Antalya, Turkey
| | - Michael J Simmonds
- Biorheology Research Laboratory, Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia
| |
Collapse
|
5
|
Adams Y, Jensen AR. Chip-Based Assay of Adhesion of Plasmodium falciparum-Infected Erythrocytes to Cells Under Flow. Methods Mol Biol 2022; 2470:545-556. [PMID: 35881374 DOI: 10.1007/978-1-0716-2189-9_42] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Unique to Plasmodium falciparum malaria parasites, the mature asexual stages of the life cycle are absent from the peripheral blood stream. Using syringe pumps and commercially available microslides, it is possible to mimic the blood flow, and investigate the interactions of erythrocytes infected by well-defined P. falciparum isolates for their ability to bind to various tissue receptors under physiological flow conditions. This chapter outlines the techniques needed to investigate how parasites bind to endothelial cells under physiological sheer stress conditions.
Collapse
Affiliation(s)
- Yvonne Adams
- Department of Immunology and Microbiology, Faculty of Health and Medical Sciences, Centre for Medical Parasitology, University of Copenhagen, Copenhagen, Denmark.
| | - Anja Ramstedt Jensen
- Department of Immunology and Microbiology, Faculty of Health and Medical Sciences, Centre for Medical Parasitology, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
6
|
Biomechanical properties of endothelial glycocalyx: An imperfect pendulum. Matrix Biol Plus 2021; 12:100087. [PMID: 34820618 PMCID: PMC8596327 DOI: 10.1016/j.mbplus.2021.100087] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 10/11/2021] [Accepted: 10/11/2021] [Indexed: 01/18/2023] Open
Abstract
This review seeks to fuse the discoveries in cell biology with mechanical engineering to produce a comprehensive biophysical model of endothelial glycocalyx. The aperiodic oscillatory motions of glycocalyx and cortical actin web underlie our prediction of two functional pacemakers and their participation in the outside-in signaling, the basis for mechanotransduction, and the dampening action of the inside-out signaling. Advancing an idea that the glycocalyx, plasma membrane, and cortical actin web represent a structure-functional unit and proposing the concept of tensegrity model. Presentation of our recent data suggesting that erythrocytes are gliding or havering and rotating over the surface of intact glycocalyx, whereas the rotational and hovering components of their passage along the capillaries are lost when glycocalyx of either is degraded.
Endothelial glycocalyx plays a crucial role in hemodynamics in health and disease, yet studying it is met by multiple technical hindrances. We attempted to outline our views on some biomechanical properties of endothelial glycocalyx, which are potentially amenable to mathematical modeling. We start with the null-hypothesis ascribing to glycocalyx the properties of a pendulum and reject this hypothesis on the grounds of multiple obstacles for pendulum behavior, such as rich decoration with flexible negatively charged side-chains, variable length and density, fluid fixation to the plasma membrane. We next analyze the current views on membrane attachments to the cortical actin web, its pulsatile contraction-relaxation cycles which rebound to the changes in tension of the plasma membrane. Based on this, we consider the outside-in signaling, the basis for mechanotransduction, and the dampening action of the inside-out signaling. The aperiodic oscillatory motions of glycocalyx and cortical actin web underlie our prediction of two functional pacemakers. We next advance an idea that the glycocalyx, plasma membrane, and cortical actin web represent a structure-functional unit and propose the concept of tensegrity model. Finally, we present our recent data suggesting that erythrocytes are gliding or hovering and rotating over the surface of intact glycocalyx, whereas the rotational and hovering components of their passage along the capillaries are lost when glycocalyx of either is degraded. These insights into the mechanics of endothelial glycocalyx motions may be of value in crosspollination between biomechanics, physiology, and pathophysiology for deeper appreciation of its rich untapped resources in health and pharmacotherapy in disease.
Collapse
|
7
|
Kwon T, Choi K, Han J. Separation of Ultra-High-Density Cell Suspension via Elasto-Inertial Microfluidics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2101880. [PMID: 34396694 DOI: 10.1002/smll.202101880] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 05/24/2021] [Indexed: 05/20/2023]
Abstract
Separation of high-density suspension particles at high throughput is crucial for many chemical, biomedical, and environmental applications. In this study, elasto-inertial microfluidics is used to manipulate ultra-high-density cells to achieve stable equilibrium positions in microchannels, aided by the inherent viscoelasticity of high-density cell suspension. It is demonstrated that ultra-high-density Chinese hamster ovary cell suspension (>26 packed cell volume% (PCV%), >95 million cells mL-1 ) can be focused at distinct lateral equilibrium positions under high-flow-rate conditions (up to 10 mL min-1 ). The effect of flow rates, channel dimensions, and cell densities on this unique focusing behavior is studied. Cell clarification is further demonstrated using this phenomenon, from 29.7 PCV% (108.1 million cells mL-1 ) to 8.3 PCV% (33.2 million cells mL-1 ) with overall 72.1% reduction efficiency and 10 mL min-1 processing rate. This work explores an extreme case of elasto-inertial particle focusing where ultra-high-density culture suspension is efficiently manipulated at high throughput. This result opens up new opportunities for practical applications of high-particle-density suspension manipulation.
Collapse
Affiliation(s)
- Taehong Kwon
- Research Laboratory of Electronics, Massachusetts Institute of Technology, 50 Vassar Street, Cambridge, MA, 02142, USA
| | - Kyungyong Choi
- Research Laboratory of Electronics, Massachusetts Institute of Technology, 50 Vassar Street, Cambridge, MA, 02142, USA
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 50 Vassar Street, Cambridge, MA, 02142, USA
| | - Jongyoon Han
- Research Laboratory of Electronics, Massachusetts Institute of Technology, 50 Vassar Street, Cambridge, MA, 02142, USA
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 50 Vassar Street, Cambridge, MA, 02142, USA
- Department of Biological Engineering, Massachusetts Institute of Technology, 50 Vassar Street, Cambridge, MA, 02142, USA
| |
Collapse
|
8
|
Chen Y, Li Z, Bai X, Feng Y, Feng L, Zhang D, Chen H, Chen H. Reduction of Erythrocyte Fluid Adaptability Due to Cell Membrane Hardening Based on Single-Cell Analysis. BIOCHIP JOURNAL 2021. [DOI: 10.1007/s13206-021-00005-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
9
|
Zhang X, Caruso C, Lam WA, Graham MD. Flow-induced segregation and dynamics of red blood cells in sickle cell disease. PHYSICAL REVIEW FLUIDS 2020; 5:053101. [PMID: 34095646 PMCID: PMC8174308 DOI: 10.1103/physrevfluids.5.053101] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Blood flow in sickle cell disease (SCD) can substantially differ from normal blood flow due to significant alterations in the physical properties of the red blood cells (RBCs). Chronic complications, such as inflammation of the endothelial cells lining blood vessel walls, are associated with SCD, for reasons that are unclear. Here, detailed boundary integral simulations are performed to investigate an idealized model flow flow in SCD, a binary suspension of flexible biconcave discoidal fluid-filled capsules and stiff curved prolate capsules that represent healthy and sickle RBCs, respectively, subjected to pressure-driven flow in a planar slit. The stiff component is dilute. The key observation is that, unlike healthy RBCs that concentrate around the center of the channel and form an RBC-depleted layer (i.e. cell-free layer) next to the walls, sickle cells are largely drained from the bulk of the suspension and aggregate inside the cell-free layer, displaying strong margination. These cells are found to undergo a rigid-body-like rolling orbit near the walls. A binary suspension of flexible biconcave discoidal capsules and stiff straight (non-curved) prolate capsules is also considered for comparison, and the curvature of the stiff component is found to play a minor role in the behavior. Additionally, by considering a mixture of flexible and stiff biconcave discoids, we reveal that rigidity difference by itself is sufficient to induce the segregation behavior in a binary suspension. Furthermore, the additional shear stress on the walls induced by the presence of cells is computed for the various cases. Compared to the small fluctuations in wall shear stress for a suspension of healthy RBCs, large local peaks in wall shear stress are observed for the binary suspensions, due to the proximity of the marginated stiff cells to the walls. This effect is most marked for the straight prolate capsules. As endothelial cells are known to mechanotransduce physical forces such as aberrations in shear stress and convert them to physiological processes such as activation of inflammatory signals, these results may aid in understanding mechanisms for endothelial dysfunction associated with SCD.
Collapse
Affiliation(s)
- Xiao Zhang
- Department of Chemical and Biological Engineering, University of Wisconsin-Madison, Madison, WI 53706-1691
| | - Christina Caruso
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer and Blood Disorders Center of Children’s Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322
| | - Wilbur A. Lam
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer and Blood Disorders Center of Children’s Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322
- Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, GA 30332
- Winship Cancer Institute, Emory University, Atlanta, GA 30322
- Parker H. Petit Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA 30332
| | - Michael D. Graham
- Department of Chemical and Biological Engineering, University of Wisconsin-Madison, Madison, WI 53706-1691
| |
Collapse
|
10
|
Czaja B, Gutierrez M, Závodszky G, de Kanter D, Hoekstra A, Eniola-Adefeso O. The influence of red blood cell deformability on hematocrit profiles and platelet margination. PLoS Comput Biol 2020; 16:e1007716. [PMID: 32163405 PMCID: PMC7093031 DOI: 10.1371/journal.pcbi.1007716] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 03/24/2020] [Accepted: 02/05/2020] [Indexed: 12/29/2022] Open
Abstract
The influence of red blood cell (RBC) deformability in whole blood on platelet margination is investigated using confocal microscopy measurements of flowing human blood and cell resolved blood flow simulations. Fluorescent platelet concentrations at the wall of a glass chamber are measured using confocal microscopy with flowing human blood containing varying healthy-to-stiff RBC fractions. A decrease is observed in the fluorescent platelet signal at the wall due to the increase of stiffened RBCs in flow, suggesting a decrease of platelet margination due to an increased fraction of stiffened RBCs present in the flow. In order to resolve the influence of stiffened RBCs on platelet concentration at the channel wall, cell-pair and bulk flow simulations are performed. For homogeneous collisions between RBC pairs, a decrease in final displacement after a collision with increasing membrane stiffness is observed. In heterogeneous collisions between healthy and stiff RBC pairs, it is found that the stiffened RBC is displaced most. The influence of RBC deformability on collisions between RBCs and platelets was found to be negligible due to their size and mass difference. For a straight vessel geometry with varying healthy-to-stiff RBC ratios, a decrease was observed in the red blood cell-free layer and platelet margination due to an increase in stiffened RBCs present in flow.
Collapse
Affiliation(s)
- Benjamin Czaja
- Computational Science Lab, Faculty of Science, Institute for Informatics, University of Amsterdam, Amsterdam, Netherlands
| | - Mario Gutierrez
- Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan, United States of America
| | - Gábor Závodszky
- Computational Science Lab, Faculty of Science, Institute for Informatics, University of Amsterdam, Amsterdam, Netherlands
- Department of Hydrodynamic Systems, Budapest University of Technology and Economics, Budapest, Hungary
| | - David de Kanter
- Computational Science Lab, Faculty of Science, Institute for Informatics, University of Amsterdam, Amsterdam, Netherlands
| | - Alfons Hoekstra
- Computational Science Lab, Faculty of Science, Institute for Informatics, University of Amsterdam, Amsterdam, Netherlands
| | - Omolola Eniola-Adefeso
- Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan, United States of America
| |
Collapse
|
11
|
Jensen AR, Adams Y, Hviid L. Cerebral Plasmodium falciparum malaria: The role of PfEMP1 in its pathogenesis and immunity, and PfEMP1-based vaccines to prevent it. Immunol Rev 2020; 293:230-252. [PMID: 31562653 PMCID: PMC6972667 DOI: 10.1111/imr.12807] [Citation(s) in RCA: 94] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Revised: 09/04/2019] [Accepted: 09/09/2019] [Indexed: 12/13/2022]
Abstract
Malaria, a mosquito-borne infectious disease caused by parasites of the genus Plasmodium continues to be a major health problem worldwide. The unicellular Plasmodium-parasites have the unique capacity to infect and replicate within host erythrocytes. By expressing variant surface antigens Plasmodium falciparum has evolved to avoid protective immune responses; as a result in endemic areas anti-malaria immunity develops gradually over many years of multiple and repeated infections. We are studying the role of Plasmodium falciparum erythrocyte membrane protein 1 (PfEMP1) expressed by asexual stages of P. falciparum responsible for the pathogenicity of severe malaria. The immunopathology of falciparum malaria has been linked to cyto-adhesion of infected erythrocytes to specific host receptors. A greater appreciation of the PfEMP1 molecules important for the development of protective immunity and immunopathology is a prerequisite for the rational discovery and development of a safe and protective anti-disease malaria vaccine. Here we review the role of ICAM-1 and EPCR receptor adhering falciparum-parasites in the development of severe malaria; we discuss our current research to understand the factors involved in the pathogenesis of cerebral malaria and the feasibility of developing a vaccine targeted specifically to prevent this disease.
Collapse
Affiliation(s)
- Anja Ramstedt Jensen
- Centre for Medical Parasitology at Department of Immunology and MicrobiologyFaculty of Health and Medical SciencesUniversity of CopenhagenCopenhagenDenmark
| | - Yvonne Adams
- Centre for Medical Parasitology at Department of Immunology and MicrobiologyFaculty of Health and Medical SciencesUniversity of CopenhagenCopenhagenDenmark
| | - Lars Hviid
- Centre for Medical Parasitology at Department of Immunology and MicrobiologyFaculty of Health and Medical SciencesUniversity of CopenhagenCopenhagenDenmark
- Department of Infectious DiseasesRigshospitaletCopenhagenDenmark
| |
Collapse
|
12
|
Horobin JT, Sabapathy S, Simmonds MJ. Red blood cell tolerance to shear stress above and below the subhemolytic threshold. Biomech Model Mechanobiol 2019; 19:851-860. [PMID: 31720887 DOI: 10.1007/s10237-019-01252-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Accepted: 11/05/2019] [Indexed: 12/20/2022]
Abstract
Mechanical circulatory support device (MCS) design has improved over the years and yet blood damage (e.g., hemolysis) remains a problem. Accumulating evidence indicates a subhemolytic threshold for red blood cells (RBC)-a threshold at which RBC deformability is impaired prior to hemolysis. The current study aimed to assess the deformability of RBC exposed to supra-physiological shear stresses that are typical of MCS devices and assess whether a method used to estimate an individualized subhemolytic threshold, accurately demarcates whether future application of shear stress was damaging. Suspensions of RBC were "conditioned" with discrete magnitudes of shear stress (5-100 Pa) for specific durations (1-16 s). Cellular deformability was subsequently measured via ektacytometry and a mechanical sensitivity (MS) index was calculated to identify the subhemolytic threshold. Thereafter, fresh RBC suspensions were exposed to a magnitude of shear stress 10 Pa above, 10 Pa below, or matched to a donor's previously estimated subhemolytic threshold for a given duration (1, 4, 16 s) to ascertain the sensitivity of the subhemolytic threshold. The MS index of RBC was significantly impaired following exposure to 10 Pa above the subhemolytic threshold (p < 0.0001), and significantly enhanced following exposure to 10 Pa below the subhemolytic threshold (p < 0.01). For all shear conditions, there was no significant increase in free hemoglobin. Functional assessments of RBC may be useful when conducting biocompatibility testing of MCS devices, to detect trauma to blood prior to overt cell rupture being induced.
Collapse
Affiliation(s)
- Jarod T Horobin
- Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia. .,Biorheology Research Laboratory, Griffith University, Gold Coast, Australia.
| | - Surendran Sabapathy
- Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia
| | - Michael J Simmonds
- Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia.,Biorheology Research Laboratory, Griffith University, Gold Coast, Australia
| |
Collapse
|
13
|
Cooley M, Sarode A, Hoore M, Fedosov DA, Mitragotri S, Sen Gupta A. Influence of particle size and shape on their margination and wall-adhesion: implications in drug delivery vehicle design across nano-to-micro scale. NANOSCALE 2018; 10:15350-15364. [PMID: 30080212 PMCID: PMC6247903 DOI: 10.1039/c8nr04042g] [Citation(s) in RCA: 148] [Impact Index Per Article: 21.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Intravascular drug delivery technologies majorly utilize spherical nanoparticles as carrier vehicles. Their targets are often at the blood vessel wall or in the tissue beyond the wall, such that vehicle localization towards the wall (margination) becomes a pre-requisite for their function. To this end, some studies have indicated that under flow environment, micro-particles have a higher propensity than nano-particles to marginate to the wall. Also, non-spherical particles theoretically have a higher area of surface-adhesive interactions than spherical particles. However, detailed systematic studies that integrate various particle size and shape parameters across nano-to-micro scale to explore their wall-localization behavior in RBC-rich blood flow, have not been reported. We address this gap by carrying out computational and experimental studies utilizing particles of four distinct shapes (spherical, oblate, prolate, rod) spanning nano- to-micro scale sizes. Computational studies were performed using the Large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS) package, with Dissipative Particle Dynamics (DPD). For experimental studies, model particles were made from neutrally buoyant fluorescent polystyrene spheres, that were thermo-stretched into non-spherical shapes and all particles were surface-coated with biotin. Using microfluidic setup, the biotin-coated particles were flowed over avidin-coated surfaces in absence versus presence of RBCs, and particle adhesion and retention at the surface was assessed by inverted fluorescence microscopy. Our computational and experimental studies provide a simultaneous analysis of different particle sizes and shapes for their retention in blood flow and indicate that in presence of RBCs, micro-scale non-spherical particles undergo enhanced 'margination + adhesion' compared to nano-scale spherical particles, resulting in their higher binding. These results provide important insight regarding improved design of vascularly targeted drug delivery systems.
Collapse
Affiliation(s)
- Michaela Cooley
- Case Western Reserve University, Department of Biomedical Engineering, Cleveland, Ohio, USA.
| | | | | | | | | | | |
Collapse
|
14
|
Chen Y, Feng Y, Wan J, Chen H. Enhanced separation of aged RBCs by designing channel cross section. BIOMICROFLUIDICS 2018; 12:024106. [PMID: 29576837 PMCID: PMC5849466 DOI: 10.1063/1.5024598] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Accepted: 03/02/2018] [Indexed: 05/31/2023]
Abstract
Prolonged storage will alter the biophysical properties of red blood cells (RBCs), and it decreases the quality of stored blood for blood transfusion. It has been known that less deformable aged RBCs can be separated by margination, but the recognition of the storage time from the separation efficiency of the stiff RBCs is still a challenge. In this study, we realized enhanced separation of aged RBCs from normal RBCs by controlling the channel cross section and demonstrated that the storage time can be deduced from the percentage of the separated RBCs in the stored RBCs. This separation technology helps to reveal the regulation of time on the RBC aging mechanism and offer a new method to separate stiffened cells with high efficiency.
Collapse
Affiliation(s)
- Yuanyuan Chen
- State Key Laboratory of Tribology, Tsinghua University, Beijing 100084, China
| | - Yuzhen Feng
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Jiandi Wan
- Department of Microsystem Engineering, Rochester Institute of Technology, Rochester, New York 14623-5608, USA
| | - Haosheng Chen
- State Key Laboratory of Tribology, Tsinghua University, Beijing 100084, China
| |
Collapse
|