Chappell D, Yang Z, Clark AB, Berkovic A, Laganier C, Baxter W, Bello F, Kormushev P, Rojas N. Examining the physical and psychological effects of combining multimodal feedback with continuous control in prosthetic hands. Sci Rep 2025; 15:3690. [PMID: 39880874 PMCID: PMC11779825 DOI: 10.1038/s41598-025-87048-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 01/15/2025] [Indexed: 01/31/2025] Open
Abstract
Myoelectric prosthetic hands are typically controlled to move between discrete positions and do not provide sensory feedback to the user. In this work, we present and evaluate a closed-loop, continuous myoelectric prosthetic hand controller, that can continuously control the position of multiple degrees of freedom of a prosthesis while rendering proprioceptive feedback to the user via a haptic feedback armband. Twenty-eight participants without and ten participants with upper limb difference (ULD) were recruited to holistically evaluate the physical and psychological effects of the controller via isolated control and sensory tasks, dexterity assessments, embodiment and task load questionnaires, and post-study interviews. The combination of proprioceptive feedback and continuous control enabled more accurate position and force modulation than without proprioceptive feedback, and restored blindfolded object identification ability to open-loop discrete controller levels. Dexterity assessment and embodiment questionnaire results revealed no significant physical performance or psychological embodiment differences between control types, with the exception of perceived sensation questions, which were significantly higher (p < 0.001) for closed-loop controllers. Key differences between participants with and without ULD were identified, including increasingly lower perceived body completeness and heterogeneity in frustration in participants with ULD, which can inform future development and rehabilitation.
Collapse
Affiliation(s)
- Digby Chappell
- Dyson School of Design Engineering, Faculty of Engineering, Imperial College London, London, UK.
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, UK.
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, USA.
| | - Zeyu Yang
- Department of Engineering Science, University of Oxford, Oxford, UK
| | - Angus B Clark
- Department of Bioengineering, Faculty of Engineering, Imperial College London, London, UK
| | - Alexandre Berkovic
- MIT Sloane School of Management, Massachusetts Institute of Technology, Boston, USA
- MIT Operations Research Centre, Massachusetts Institute of Technology, Boston, USA
| | - Colin Laganier
- Department of Computer Science, Faculty of Engineering, University College London, London, UK
| | - Weston Baxter
- Dyson School of Design Engineering, Faculty of Engineering, Imperial College London, London, UK
| | - Fernando Bello
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, UK
| | - Petar Kormushev
- Dyson School of Design Engineering, Faculty of Engineering, Imperial College London, London, UK
| | | |
Collapse
|
2
|
Demirdel S, Demirdel E, Söyler O, Akyol M. Reliability and validity of the Turkish version of the Prosthesis Embodiment Scale for Lower Limb Amputees. Prosthet Orthot Int 2024; 48:727-733. [PMID: 38506639 DOI: 10.1097/pxr.0000000000000332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 12/18/2023] [Indexed: 03/21/2024]
Abstract
BACKGROUND Prosthetic embodiment is the perception of the prosthesis as a part of the body, and it is important for acceptance and adequate and effective use of the prosthesis. OBJECTIVE The aim of this study was to investigate the validity and reliability of the Turkish version of the Prosthesis Embodiment Scale for Lower Limb Amputees. METHODS This cross-sectional study included a total of 88 lower limb amputees. Internal consistency was evaluated using Cronbach α coefficient. The test-retest reliability of the scale, which was reapplied after 7-10 d, was evaluated using intraclass correlation coefficient. Principal component analysis with Varimax rotation was used to analyze the factor structure. Spearman correlation coefficient with Trinity Amputation and Prosthesis Experience Scale subscales was calculated for concurrent validity. RESULTS The mean age of the participants was 45.13 ± 15.05 years, and 76.1% were male. Internal consistency (Cronbach α = 0.905) and test-retest reliability (intraclass correlation coefficient = 0.822) were high. 76.1% of the total variance could be explained by the 3 dimensions. Significant correlation was found with the Trinity Amputation and Prosthesis Experience Scale subscales (r = 0.542 for psychosocial adjustment subscale, r = -0.452 for activity restriction subscale, r = 0.490 for prosthesis satisfaction subscale, p < 0.001). CONCLUSIONS The results of this study showed that the Turkish version of the Prosthesis Embodiment Scale for Lower Limb Amputees is a valid and reliable tool that can be used to evaluate prosthetic rehabilitation outcomes.
Collapse
Affiliation(s)
- Senem Demirdel
- Gülhane Faculty of Physiotherapy and Rehabilitation, University of Health Sciences Turkey, Ankara, Turkey
| | - Ertuğrul Demirdel
- Gülhane Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Ankara Yıldırım Beyazıt University, Ankara, Turkey
| | - Osman Söyler
- Health Sciences Institute, Lokman Hekim University, Ankara, Turkey
| | - Mesut Akyol
- Department of Biostatistics and Medical Informatics, Faculty of Medicine, Ankara Yıldırım Beyazıt University, Ankara, Turkey
| |
Collapse
|
3
|
Olsen CD, Olsen NR, Stone ES, Tully TN, Paskett MD, Teramoto M, Clark GA, George JA. Electromyographically controlled prosthetic wrist improves dexterity and reduces compensatory movements without added cognitive load. Sci Rep 2024; 14:23248. [PMID: 39370497 PMCID: PMC11456584 DOI: 10.1038/s41598-024-73855-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Accepted: 09/20/2024] [Indexed: 10/08/2024] Open
Abstract
Wrist function is a top priority for transradial amputees. However, the combined functional, biomechanical, and cognitive impact of using a powered prosthetic wrist is unclear. Here, we quantify task performance, compensatory movements, and cognitive load while three transradial amputees performed a modified Clothespin Relocation Task using two myoelectric prostheses with and without the wrists. The two myoelectric prostheses include a commercial prosthesis with a built-in powered wrist, and a newly developed inexpensive prosthetic wrist for research purposes, called the "Utah wrist", that can be adapted to work with various sockets and prostheses. For these three participants, task failure rate decreased significantly from 66% ± 12% without the wrist to 39% ± 9% with the Utah wrist. Compensatory forward leaning movements also decreased significantly, from 24.2° ± 2.5 without the wrist to 12.6° ± 1.0 with the Utah wrist, and from 23.6° ± 7.6 to 15.3° ± 7.2 with the commercial prosthesis with an integrated wrist. Compensatory leftward bending movements also significantly decreased, from 20.8° ± 8.6 to 12.3° ± 5.3, for the commercial with an integrated wrist. Importantly, simultaneous myoelectric control of either prosthetic wrist had no significant impact on cognitive load, as assessed by the NASA Task Load Index survey and a secondary detection response task. This work suggests that functional prosthetic wrists can improve dexterity and reduce compensation without significantly increasing cognitive effort. These results, and the introduction of a new inexpensive prosthetic wrist for research purposes, can aid future research and development and guide the prescription of upper-limb prostheses.
Collapse
Affiliation(s)
- Connor D Olsen
- Department of Electrical Engineering, University of Utah, Salt Lake City, USA.
| | - Nathaniel R Olsen
- Department of Mechanical Engineering, University of Utah, Salt Lake City, USA
| | - Eric S Stone
- Department of Biomedical Engineering, University of Utah, Salt Lake City, USA
| | - Troy N Tully
- Department of Biomedical Engineering, University of Utah, Salt Lake City, USA
| | - Michael D Paskett
- Department of Biomedical Engineering, University of Utah, Salt Lake City, USA
| | - Masaru Teramoto
- Department of Physical Medicine and Rehabilitation, University of Utah, Salt Lake City, USA
| | - Gregory A Clark
- Department of Biomedical Engineering, University of Utah, Salt Lake City, USA
| | - Jacob A George
- Department of Electrical Engineering, University of Utah, Salt Lake City, USA
- Department of Mechanical Engineering, University of Utah, Salt Lake City, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, USA
- Department of Physical Medicine and Rehabilitation, University of Utah, Salt Lake City, USA
| |
Collapse
|
4
|
Engdahl SM, Gonzalez MA, Lee C, Gates DH. Perspectives on the comparative benefits of body-powered and myoelectric upper limb prostheses. J Neuroeng Rehabil 2024; 21:138. [PMID: 39118106 PMCID: PMC11308580 DOI: 10.1186/s12984-024-01436-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 07/28/2024] [Indexed: 08/10/2024] Open
Abstract
BACKGROUND Patient access to body-powered and myoelectric upper limb prostheses in the United States is often restricted by a healthcare system that prioritizes prosthesis prescription based on cost and perceived value. Although this system operates on an underlying assumption that design differences between these prostheses leads to relative advantages and disadvantages of each device, there is limited empirical evidence to support this view. MAIN TEXT This commentary article will review a series of studies conducted by our research team with the goal of differentiating how prosthesis design might impact user performance on a variety of interrelated domains. Our central hypothesis is that the design and actuation method of body-powered and myoelectric prostheses might affect users' ability to access sensory feedback and account for device properties when planning movements. Accordingly, other domains that depend on these abilities may also be affected. While our work demonstrated some differences in availability of sensory feedback based on prosthesis design, this did not result in consistent differences in prosthesis embodiment, movement accuracy, movement quality, and overall kinematic patterns. CONCLUSION Collectively, our findings suggest that performance may not necessarily depend on prosthesis design, allowing users to be successful with either device type depending on the circumstances. Prescription practices should rely more on individual needs and preferences than cost or prosthesis design. However, we acknowledge that there remains a dearth of evidence to inform decision-making and that an expanded research focus in this area will be beneficial.
Collapse
Affiliation(s)
- Susannah M Engdahl
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | | | - Christina Lee
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Deanna H Gates
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
- School of Kinesiology, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
5
|
Castañeda TS, Connan M, Capsi-Morales P, Beckerle P, Castellini C, Piazza C. Experimental evaluation of the impact of sEMG interfaces in enhancing embodiment of virtual myoelectric prostheses. J Neuroeng Rehabil 2024; 21:57. [PMID: 38627772 PMCID: PMC11020298 DOI: 10.1186/s12984-024-01352-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 04/03/2024] [Indexed: 04/19/2024] Open
Abstract
INTRODUCTION Despite recent technological advances that have led to sophisticated bionic prostheses, attaining embodied solutions still remains a challenge. Recently, the investigation of prosthetic embodiment has become a topic of interest in the research community, which deals with enhancing the perception of artificial limbs as part of users' own body. Surface electromyography (sEMG) interfaces have emerged as a promising technology for enhancing upper-limb prosthetic control. However, little is known about the impact of these sEMG interfaces on users' experience regarding embodiment and their interaction with different functional levels. METHODS To investigate this aspect, a comparison is conducted among sEMG configurations with different number of sensors (4 and 16 channels) and different time delay. We used a regression algorithm to simultaneously control hand closing/opening and forearm pronation/supination in an immersive virtual reality environment. The experimental evaluation includes 24 able-bodied subjects and one prosthesis user. We assess functionality with the Target Achievement Control test, and the sense of embodiment with a metric for the users perception of self-location, together with a standard survey. RESULTS Among the four tested conditions, results proved a higher subjective embodiment when participants used sEMG interfaces employing an increased number of sensors. Regarding functionality, significant improvement over time is observed in the same conditions, independently of the time delay implemented. CONCLUSIONS Our work indicates that a sufficient number of sEMG sensors improves both, functional and subjective embodiment outcomes. This prompts discussion regarding the potential relationship between these two aspects present in bionic integration. Similar embodiment outcomes are observed in the prosthesis user, showing also differences due to the time delay, and demonstrating the influence of sEMG interfaces on the sense of agency.
Collapse
Affiliation(s)
| | - Mathilde Connan
- Institute of Robotics and Mechatronics, German Aerospace Center (DLR), Oberpfaffenhofen, Germany
| | - Patricia Capsi-Morales
- Department of Computer Engineering, Technical University of Munich (TUM), Garching bei Munich, Germany.
- Munich Institute of Robotics and Machine Intelligence, Technical University of Munich (TUM), Munich, Germany.
| | - Philipp Beckerle
- Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Department of Electrical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Claudio Castellini
- Institute of Robotics and Mechatronics, German Aerospace Center (DLR), Oberpfaffenhofen, Germany
- Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Cristina Piazza
- Department of Computer Engineering, Technical University of Munich (TUM), Garching bei Munich, Germany
- Munich Institute of Robotics and Machine Intelligence, Technical University of Munich (TUM), Munich, Germany
| |
Collapse
|
6
|
Abstract
Owing to the lack of trained professionals in amputee care, the pediatrician is often required to assist in the care of children with limb deficiencies. An overview of the causes and epidemiology of limb deficiency is provided, as well as an evaluation and diagnostic workup. Important considerations for surgical interventions are discussed and an introduction to prosthetic prescribing and care of the amputee is described. Common overuse syndromes and mental health issues are also reviewed. Finally, resources for funding of prosthetic devices, as well as support and education for clinicians and families are provided.
Collapse
Affiliation(s)
- Phoebe Scott-Wyard
- Division of Pediatric Rehabilitation, Department of Orthopedics, Rady Children's Hospital, University of California - San Diego, 3020 Children's Way, MC5096, San Diego, CA 92123-4223, USA.
| |
Collapse
|
7
|
Hybart RL, Ferris DP. Embodiment for Robotic Lower-Limb Exoskeletons: A Narrative Review. IEEE Trans Neural Syst Rehabil Eng 2023; 31:657-668. [PMID: 37015690 PMCID: PMC10267288 DOI: 10.1109/tnsre.2022.3229563] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Research on embodiment of objects external to the human body has revealed important information about how the human nervous system interacts with robotic lower limb exoskeletons. Typical robotic exoskeleton control approaches view the controllers as an external agent intending to move in coordination with the human. However, principles of embodiment suggest that the exoskeleton controller should ideally coordinate with the human such that the nervous system can adequately model the input-output dynamics of the exoskeleton controller. Measuring embodiment of exoskeletons should be a necessary step in the exoskeleton development and prototyping process. Researchers need to establish high fidelity quantitative measures of embodiment, rather than relying on current qualitative survey measures. Mobile brain imaging techniques, such as high-density electroencephalography, is likely to provide a deeper understanding of embodiment during human-machine interactions and advance exoskeleton research and development. In this review we show why future exoskeleton research should include quantitative measures of embodiment as a metric of success.
Collapse
|
8
|
Segil JL, Roldan LM, Graczyk EL. Measuring embodiment: A review of methods for prosthetic devices. Front Neurorobot 2022; 16:902162. [PMID: 36590084 PMCID: PMC9797051 DOI: 10.3389/fnbot.2022.902162] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 10/25/2022] [Indexed: 12/23/2022] Open
Abstract
The development of neural interfaces to provide improved control and somatosensory feedback from prosthetic limbs has initiated a new ability to probe the various dimensions of embodiment. Scientists in the field of neuroprosthetics require dependable measures of ownership, body representation, and agency to quantify the sense of embodiment felt by patients for their prosthetic limbs. These measures are critical to perform generalizable experiments and compare the utility of the new technologies being developed. Here, we review outcome measures used in the literature to evaluate the senses of ownership, body-representation, and agency. We categorize these existing measures based on the fundamental psychometric property measured and whether it is a behavioral or physiological measure. We present arguments for the efficacy and pitfalls of each measure to guide better experimental designs and future outcome measure development. The purpose of this review is to aid prosthesis researchers and technology developers in understanding the concept of embodiment and selecting metrics to assess embodiment in their research. Advances in the ability to measure the embodiment of prosthetic devices have far-reaching implications in the improvement of prosthetic limbs as well as promoting a broader understanding of ourselves as embodied agents.
Collapse
Affiliation(s)
- Jacob L. Segil
- Department of Mechanical Engineering, University of Colorado, Boulder, CO, United States
- Rocky Mountain Regional VA Medical Center, Aurora, CO, United States
| | - Leah Marie Roldan
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States
| | - Emily L. Graczyk
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States
| |
Collapse
|
9
|
Touillet A, Gouzien A, Badin M, Herbe P, Martinet N, Jarrassé N, Roby-Brami A. Kinematic analysis of impairments and compensatory motor behavior during prosthetic grasping in below-elbow amputees. PLoS One 2022; 17:e0277917. [PMID: 36399487 PMCID: PMC9674132 DOI: 10.1371/journal.pone.0277917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 11/06/2022] [Indexed: 11/19/2022] Open
Abstract
After a major upper limb amputation, the use of myoelectric prosthesis as assistive devices is possible. However, these prostheses remain quite difficult to control for grasping and manipulation of daily life objects. The aim of the present observational case study is to document the kinematics of grasping in a group of 10 below-elbow amputated patients fitted with a myoelectric prosthesis in order to describe and better understand their compensatory strategies. They performed a grasping to lift task toward 3 objects (a mug, a cylinder and a cone) placed at two distances within the reaching area in front of the patients. The kinematics of the trunk and upper-limb on the non-amputated and prosthetic sides were recorded with 3 electromagnetic Polhemus sensors placed on the hand, the forearm (or the corresponding site on the prosthesis) and the ipsilateral acromion. The 3D position of the elbow joint and the shoulder and elbow angles were calculated thanks to a preliminary calibration of the sensor position. We examined first the effect of side, distance and objects with non-parametric statistics. Prosthetic grasping was characterized by severe temporo-spatial impairments consistent with previous clinical or kinematic observations. The grasping phase was prolonged and the reaching and grasping components uncoupled. The 3D hand displacement was symmetrical in average, but with some differences according to the objects. Compensatory strategies involved the trunk and the proximal part of the upper-limb, as shown by a greater 3D displacement of the elbow for close target and a greater forward displacement of the acromion, particularly for far targets. The hand orientation at the time of grasping showed marked side differences with a more frontal azimuth, and a more "thumb-up" roll. The variation of hand orientation with the object on the prosthetic side, suggested that the lack of finger and wrist mobility imposed some adaptation of hand pose relative to the object. The detailed kinematic analysis allows more insight into the mechanisms of the compensatory strategies that could be due to both increased distal or proximal kinematic constraints. A better knowledge of those compensatory strategies is important for the prevention of musculoskeletal disorders and the development of innovative prosthetics.
Collapse
Affiliation(s)
- Amélie Touillet
- Louis Pierquin Centre of the Regional Institute of Rehabilitation, UGECAM Nord Est, Nancy, France
| | - Adrienne Gouzien
- Service de psychiatrie, Pôle Paris Centre, Hôpitaux de Saint-Maurice, Saint-Maurice, France
| | - Marina Badin
- Louis Pierquin Centre of the Regional Institute of Rehabilitation, UGECAM Nord Est, Nancy, France
| | - Pierrick Herbe
- Louis Pierquin Centre of the Regional Institute of Rehabilitation, UGECAM Nord Est, Nancy, France
| | - Noël Martinet
- Louis Pierquin Centre of the Regional Institute of Rehabilitation, UGECAM Nord Est, Nancy, France
| | - Nathanaël Jarrassé
- Institute of Intelligent Systems and Robotics (ISIR), UMR 7222, CNRS/INSERM, U1150 Agathe-ISIR, Sorbonne University, Paris, France
| | - Agnès Roby-Brami
- Institute of Intelligent Systems and Robotics (ISIR), UMR 7222, CNRS/INSERM, U1150 Agathe-ISIR, Sorbonne University, Paris, France
- * E-mail:
| |
Collapse
|
10
|
Zbinden J, Lendaro E, Ortiz-Catalan M. A multi-dimensional framework for prosthetic embodiment: a perspective for translational research. J Neuroeng Rehabil 2022; 19:122. [PMID: 36369004 PMCID: PMC9652836 DOI: 10.1186/s12984-022-01102-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Accepted: 10/25/2022] [Indexed: 11/13/2022] Open
Abstract
The concept of embodiment has gained widespread popularity within prosthetics research. Embodiment has been claimed to be an indicator of the efficacy of sensory feedback and control strategies. Moreover, it has even been claimed to be necessary for prosthesis acceptance, albeit unfoundedly. Despite the popularity of the term, an actual consensus on how prosthetic embodiment should be used in an experimental framework has yet to be reached. The lack of consensus is in part due to terminological ambiguity and the lack of an exact definition of prosthetic embodiment itself. In a review published parallel to this article, we summarized the definitions of embodiment used in prosthetics literature and concluded that treating prosthetic embodiment as a combination of ownership and agency allows for embodiment to be quantified, and thus useful in translational research. Here, we review the potential mechanisms that give rise to ownership and agency considering temporal, spatial, and anatomical constraints. We then use this to propose a multi-dimensional framework where prosthetic embodiment arises within a spectrum dependent on the integration of volition and multi-sensory information as demanded by the degree of interaction with the environment. This framework allows for the different experimental paradigms on sensory feedback and prosthetic control to be placed in a common perspective. By considering that embodiment lays along a spectrum tied to the interactions with the environment, one can conclude that the embodiment of prosthetic devices should be assessed while operating in environments as close to daily life as possible for it to become relevant.
Collapse
|
11
|
A review of user needs to drive the development of lower limb prostheses. J Neuroeng Rehabil 2022; 19:119. [PMCID: PMC9636812 DOI: 10.1186/s12984-022-01097-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 10/25/2022] [Indexed: 11/08/2022] Open
Abstract
Abstract
Background
The development of bionic legs has seen substantial improvements in the past years but people with lower-limb amputation still suffer from impairments in mobility (e.g., altered balance and gait control) due to significant limitations of the contemporary prostheses. Approaching the problem from a human-centered perspective by focusing on user-specific needs can allow identifying critical improvements that can increase the quality of life. While there are several reviews of user needs regarding upper limb prostheses, a comprehensive summary of such needs for those affected by lower limb loss does not exist.
Methods
We have conducted a systematic review of the literature to extract important needs of the users of lower-limb prostheses. The review included 56 articles in which a need (desire, wish) was reported explicitly by the recruited people with lower limb amputation (N = 8149).
Results
An exhaustive list of user needs was collected and subdivided into functional, psychological, cognitive, ergonomics, and other domain. Where appropriate, we have also briefly discussed the developments in prosthetic devices that are related to or could have an impact on those needs. In summary, the users would like to lead an independent life and reintegrate into society by coming back to work and participating in social and leisure activities. Efficient, versatile, and stable gait, but also support to other activities (e.g., sit to stand), contribute to safety and confidence, while appearance and comfort are important for the body image. However, the relation between specific needs, objective measures of performance, and overall satisfaction and quality of life is still an open question.
Conclusions
Identifying user needs is a critical step for the development of new generation lower limb prostheses that aim to improve the quality of life of their users. However, this is not a simple task, as the needs interact with each other and depend on multiple factors (e.g., mobility level, age, gender), while evolving in time with the use of the device. Hence, novel assessment methods are required that can evaluate the impact of the system from a holistic perspective, capturing objective outcomes but also overall user experience and satisfaction in the relevant environment (daily life).
Collapse
|
12
|
Engdahl SM, Lee C, Gates DH. A comparison of compensatory movements between body-powered and myoelectric prosthesis users during activities of daily living. Clin Biomech (Bristol, Avon) 2022; 97:105713. [PMID: 35809535 DOI: 10.1016/j.clinbiomech.2022.105713] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 06/17/2022] [Accepted: 06/24/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND People with upper limb absence use compensatory movements to accommodate lack of motion in the prosthetic hand. The purpose of this study was to determine if the type of prosthesis used (i.e. body-powered or myoelectric) affects compensatory movements during activities of daily living. METHODS Twelve transradial body-powered and/or myoelectric prosthesis users performed up to six unimanual and bimanual activities of daily living. Trunk range of motion and peak upper limb angles for each task were compared between prostheses. FINDINGS Compensatory movement generally did not differ based on prosthesis type. However, body-powered users had increased trunk lateral lean compared to myoelectric users during a deodorant application task (P = 0.025). Body-powered users also had increased trunk axial rotation (P = 0.048) and decreased shoulder elevation (P = 0.046) when transferring a box between shelves. Compensatory movements were not systematically correlated with duration of prosthesis ownership, socket comfort, or terminal device type. INTERPRETATION A prosthesis user's compensatory movements may depend on other factors beyond whether the prosthesis terminal device is actuated through body-powered or myoelectric mechanisms. Further exploration of the factors that influence joint kinematics in prosthesis users may inform future prosthesis prescription practices and help patients become successful users.
Collapse
Affiliation(s)
- Susannah M Engdahl
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Christina Lee
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Deanna H Gates
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA; School of Kinesiology, University of Michigan, Ann Arbor, MI, USA.
| |
Collapse
|
13
|
The use of myoelectric prosthesis in a sample of veterans with unilateral upper extremity amputation: prosthesis satisfaction and quality of life. Ir J Med Sci 2022; 192:839-845. [PMID: 35715662 DOI: 10.1007/s11845-022-03062-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 06/08/2022] [Indexed: 10/18/2022]
Abstract
AIMS To determine the relationship between clinic and prosthesis-related characteristics and psychosocial adjustment, activity restriction, satisfaction with the prosthesis and quality of life in myoelectric prosthesis users with upper limb amputation. METHODS Thirty patients with myoelectric prosthesis users with upper limb amputation took part in this study. The patients' demographic and clinical information were recorded. Psychosocial adjustment, activity restriction and satisfaction with the prosthesis were assessed with Trinity Amputation and Prosthesis Experience Scales-Revised (TAPES-R). Short-Form 36 (SF-36) was used for the quality of life. RESULTS TAPES-R activity restriction score was significantly higher in patients with transhumeral or elbow disarticulation and with concomitant lower limb amputation (p = 0.009, p = 0.037, respectively). TAPES-R psychosocial adjustment subparameter score had significantly moderate correlation with daily prosthesis wearing time (p = 0.019 r = 0.425). A significant negative correlation was found between age at the time of the injury and SF-36 role limitation due to physical problem (p = 0.028 r = - 0.401). CONCLUSIONS Clarifying the factors related to psychosocial adjustment, activity restriction, prosthesis satisfaction and quality of life in individuals with upper extremity amputation and producing interventions/approaches that support patients' life are meaningful and important steps. CLINICAL TRIAL REGISTER E2-22-1416.
Collapse
|
14
|
Osborn LE, Moran C, Dodd LD, Sutton E, Norena Acosta N, Wormley J, Pyles CO, Gordge KD, Nordstrom M, Butkus J, Forsberg JA, Pasquina P, Fifer MS, Armiger RS. Monitoring at-home prosthesis control improvements through real-time data logging. J Neural Eng 2022; 19. [PMID: 35523131 DOI: 10.1088/1741-2552/ac6d7b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 05/06/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Validating the ability for advanced prostheses to improve function beyond the laboratory remains a critical step in enabling long-term benefits for prosthetic limb users. APPROACH A nine week take-home case study was completed with a single participant with upper limb amputation and osseointegration (OI) to better understand how an advanced prosthesis is used during daily activities. The participant was already an expert prosthesis user and used the Modular Prosthetic Limb (MPL) at home during the study. The MPL was controlled using wireless electromyography (EMG) pattern recognition-based movement decoding. Clinical assessments were performed before and after the take-home portion of the study. Data was recorded using an onboard data log in order to measure daily prosthesis usage, sensor data, and EMG data. MAIN RESULT The participant's continuous prosthesis usage steadily increased (p = 0.04, max = 5.5 hr) over time and over 30% of the total time was spent actively controlling the prosthesis. The duration of prosthesis usage after each pattern recognition training session also increased over time (p = 0.04), resulting in up to 5.4 hr of usage before retraining the movement decoding algorithm. Pattern recognition control accuracy improved (1.2% per week, p < 0.001) with a maximum number of 10 classes trained at once and the transitions between different degrees of freedom increased as the study progressed, indicating smooth and efficient control of the advanced prosthesis. Variability of decoding accuracy also decreased with prosthesis usage (p < 0.001) and 30% of the time was spent performing a prosthesis movement. During clinical evaluations, Box and Blocks and the Assessment of the Capacity for Myoelectric Control (ACMC) scores increased by 43% and 6.2%, respectively, demonstrating prosthesis functionality and the NASA Task Load Index (NASA-TLX) scores decreased, on average, by 25% across assessments, indicating reduced cognitive workload while using the MPL, over the nine week study. SIGNIFICANCE In this case study, we demonstrate that an onboard system to monitor prosthesis usage enables better understanding of how prostheses are incorporated into daily life. That knowledge can support the long-term goal of completely restoring independence and quality of life to individuals living with upper limb amputation.
Collapse
Affiliation(s)
- Luke E Osborn
- Research & Exploratory Development, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| | - Courtney Moran
- Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| | - Lauren D Dodd
- Henry M Jackson Foundation for the Advancement of Military Medicine, 6720A Rockledge Dr, Bethesda, Maryland, 20817, UNITED STATES
| | - Erin Sutton
- Research & Exploratory Development, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| | - Nicolas Norena Acosta
- Research & Exploratory Development, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| | - Jared Wormley
- Research & Exploratory Development, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| | - Connor O Pyles
- Research & Exploratory Development, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| | - Kelles D Gordge
- Research & Exploratory Development, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| | - Michelle Nordstrom
- Department of Rehabilitation, Walter Reed National Military Medical Center, 4494 Palmer Rd N, Bethesda, 20889, UNITED STATES
| | - Josef Butkus
- Department of Rehabilitation, Walter Reed National Military Medical Center, 4494 Palmer Rd N, Bethesda, 20889, UNITED STATES
| | - Jonathan A Forsberg
- Department of Orthopaedic Surgery, Johns Hopkins Medicine, 1800 Orleans St, Baltimore, Maryland, 21287, UNITED STATES
| | - Paul Pasquina
- Department of Rehabilitation, Walter Reed National Military Medical Center, 4494 Palmer Rd N, Bethesda, Maryland, 20814, UNITED STATES
| | - Matthew S Fifer
- Research & Exploratory Development, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| | - Robert S Armiger
- Research & Exploratory Development, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, Maryland, 20723, UNITED STATES
| |
Collapse
|
15
|
Zbinden J, Lendaro E, Ortiz-Catalan M. Prosthetic embodiment: systematic review on definitions, measures, and experimental paradigms. J Neuroeng Rehabil 2022; 19:37. [PMID: 35346251 PMCID: PMC8962549 DOI: 10.1186/s12984-022-01006-6] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 03/04/2022] [Indexed: 11/25/2022] Open
Abstract
The term embodiment has become omnipresent within prosthetics research and is often used as a metric of the progress made in prosthetic technologies, as well as a hallmark for user acceptance. However, despite the frequent use of the term, the concept of prosthetic embodiment is often left undefined or described incongruently, sometimes even within the same article. This terminological ambiguity complicates the comparison of studies using embodiment as a metric of success, which in turn hinders the advancement of prosthetics research. To resolve these terminological ambiguities, we systematically reviewed the used definitions of embodiment in the prosthetics literature. We performed a thematic analysis of the definitions and found that embodiment is often conceptualized in either of two frameworks based on body representations or experimental phenomenology. We concluded that treating prosthetic embodiment within an experimental phenomenological framework as the combination of ownership and agency allows for embodiment to be a quantifiable metric for use in translational research. To provide a common reference and guidance on how to best assess ownership and agency, we conducted a second systematic review, analyzing experiments and measures involving ownership and agency. Together, we highlight a pragmatic definition of prosthetic embodiment as the combination of ownership and agency, and in an accompanying article, we provide a perspective on a multi-dimensional framework for prosthetic embodiment. Here, we concluded by providing recommendations on metrics that allow for outcome comparisons between studies, thereby creating a common reference for further discussions within prosthetics research.
Collapse
Affiliation(s)
- Jan Zbinden
- Center for Bionics and Pain Research, Mölndal, Sweden
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Eva Lendaro
- Center for Bionics and Pain Research, Mölndal, Sweden
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Max Ortiz-Catalan
- Center for Bionics and Pain Research, Mölndal, Sweden.
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
- Operational Area 3, Sahlgrenska University Hospital, Gothenburg, Sweden.
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
16
|
Rekant J, Fisher LE, Boninger M, Gaunt RA, Collinger JL. Amputee, clinician, and regulator perspectives on current and prospective upper extremity prosthetic technologies. Assist Technol 2022:1-13. [PMID: 34982647 DOI: 10.1080/10400435.2021.2020935] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Existing prosthetic technologies for people with upper limb amputation are being adopted at moderate rates. Once fitted for these devices, many upper limb amputees report not using them regularly or at all. The primary aim of this study was to solicit feedback about prosthetic technology and important device design criteria from amputees, clinicians, and device regulators. We compare these perspectives to identify common or divergent priorities. Twenty-one adults with upper limb loss, 35 clinicians, and 3 regulators completed a survey on existing prosthetic technologies and a conceptual sensorimotor prosthesis driven by implanted myoelectric electrodes with sensory feedback via spinal root stimulation. The survey included questions from the Trinity Amputation and Prosthesis Experience Scale, the Disabilities of the Arm, Shoulder, and Hand, and novel questions about technology acceptance and neuroprosthetic design. User and clinician ratings of satisfaction with existing devices were similar. Amputees were most accepting of the proposed sensorimotor prosthesis (75.5% vs clinicians(68.8%), regulators(67.8%)). Stakeholders valued user-centered outcomes like individualized task goals, improved quality of life, device reliability, and user safety; regulators emphasized these last two. The results of this study provide insight into amputee, clinician, and regulator priorities to inform future upper-limb prosthetic design and clinical trial protocol development.
Collapse
Affiliation(s)
- Julie Rekant
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Lee E Fisher
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, USA.,Center for Neural Basis of Cognition, Pittsburgh, PA, USA
| | - Michael Boninger
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, USA.,Human Engineering Research Labs, VA Center of Excellence, Department of Veteran Affairs, Pittsburgh, PA, USA
| | - Robert A Gaunt
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, USA.,Center for Neural Basis of Cognition, Pittsburgh, PA, USA
| | - Jennifer L Collinger
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, USA.,Center for Neural Basis of Cognition, Pittsburgh, PA, USA.,Human Engineering Research Labs, VA Center of Excellence, Department of Veteran Affairs, Pittsburgh, PA, USA
| |
Collapse
|