1
|
Cavallo AU, Di Donna C, Troisi J, Cerimele C, Cesareni M, Chiocchi M, Floris R, Garaci F. Radiomics analysis of short tau inversion recovery images in cardiac magnetic resonance for the prediction of late gadolinium enhancement in patients with acute myocarditis. Magn Reson Imaging 2022; 94:168-173. [PMID: 36116711 DOI: 10.1016/j.mri.2022.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/31/2022] [Accepted: 09/13/2022] [Indexed: 11/16/2022]
Abstract
RATIONALE AND OBJECTIVES Cardiac Magnetic Resonance (CMR) imaging is recommended as the reference diagnostic non-invasive modality for myocarditis but is often limited by patients' compliance. The purpose of this study is to evaluate the validity of Radiomics applied to Short Tau Inversion Recovery (STIR) sequences, in predicting the presence of LGE in patients with suspected acute myocarditis. MATERIALS AND METHODS 171 STIR images on short-axis view were segmented with "MaZda" software ver 4.6, by placing a region of interest (ROI) on the left ventricle by two radiologists in consensus. Images were classified according to the presence of LGE in the equivalent short-axis T1-IR slice. A total of 337 ROI features were extracted for each image. Dataset was then split into two parts (train and test set) with 70:30 ratio. RESULTS Eleven classification models were trained. An Ensemble Machine Learning (EML) model was obtained by averaging the predictions of models with accuracy on test set >70%. The EML documented accuracy of 0.75, sensitivity of 0.8 and a specificity of 0.73 with a NPV of 0.81 and a PPV of 0.7, with AUC of 0.79 (95% CI: 0.66-0.92). CONCLUSION Radiomics and machine learning analysis could be a promising approach in reducing scan times without reducing diagnostic accuracy in predicting LGE in patients with acute myocarditis.
Collapse
Affiliation(s)
- Armando Ugo Cavallo
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Rome, Italy; Division of Radiology, San Carlo di Nancy Hospital, GVM Care and Research, Rome, Italy
| | - Carlo Di Donna
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Rome, Italy.
| | - Jacopo Troisi
- Department of Medicine, Surgery and Dentistry, "Scuola Medica Salernitana", University of Salerno, Italy; Theoreo srl - Spin-off company of the University of Salerno, Italy
| | | | | | | | - Roberto Floris
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Rome, Italy
| | - Francesco Garaci
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Rome, Italy; San Raffaele Cassino, Cassino, FR, Italy
| |
Collapse
|
2
|
Xie E, Sung E, Saad E, Trayanova N, Wu KC, Chrispin J. Advanced imaging for risk stratification for ventricular arrhythmias and sudden cardiac death. Front Cardiovasc Med 2022; 9:884767. [PMID: 36072882 PMCID: PMC9441865 DOI: 10.3389/fcvm.2022.884767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Accepted: 08/02/2022] [Indexed: 11/13/2022] Open
Abstract
Sudden cardiac death (SCD) is a leading cause of mortality, comprising approximately half of all deaths from cardiovascular disease. In the US, the majority of SCD (85%) occurs in patients with ischemic cardiomyopathy (ICM) and a subset in patients with non-ischemic cardiomyopathy (NICM), who tend to be younger and whose risk of mortality is less clearly delineated than in ischemic cardiomyopathies. The conventional means of SCD risk stratification has been the determination of the ejection fraction (EF), typically via echocardiography, which is currently a means of determining candidacy for primary prevention in the form of implantable cardiac defibrillators (ICDs). Advanced cardiac imaging methods such as cardiac magnetic resonance imaging (CMR), single-photon emission computerized tomography (SPECT) and positron emission tomography (PET), and computed tomography (CT) have emerged as promising and non-invasive means of risk stratification for sudden death through their characterization of the underlying myocardial substrate that predisposes to SCD. Late gadolinium enhancement (LGE) on CMR detects myocardial scar, which can inform ICD decision-making. Overall scar burden, region-specific scar burden, and scar heterogeneity have all been studied in risk stratification. PET and SPECT are nuclear methods that determine myocardial viability and innervation, as well as inflammation. CT can be used for assessment of myocardial fat and its association with reentrant circuits. Emerging methodologies include the development of "virtual hearts" using complex electrophysiologic modeling derived from CMR to attempt to predict arrhythmic susceptibility. Recent developments have paired novel machine learning (ML) algorithms with established imaging techniques to improve predictive performance. The use of advanced imaging to augment risk stratification for sudden death is increasingly well-established and may soon have an expanded role in clinical decision-making. ML could help shift this paradigm further by advancing variable discovery and data analysis.
Collapse
Affiliation(s)
- Eric Xie
- Division of Cardiology, Department of Medicine, Section of Cardiac Electrophysiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Eric Sung
- Division of Cardiology, Department of Medicine, Section of Cardiac Electrophysiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States
| | - Elie Saad
- Division of Cardiology, Department of Medicine, Section of Cardiac Electrophysiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Natalia Trayanova
- Division of Cardiology, Department of Medicine, Section of Cardiac Electrophysiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States
| | - Katherine C. Wu
- Division of Cardiology, Department of Medicine, Section of Cardiac Electrophysiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Jonathan Chrispin
- Division of Cardiology, Department of Medicine, Section of Cardiac Electrophysiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| |
Collapse
|
3
|
Arian F, Amini M, Mostafaei S, Rezaei Kalantari K, Haddadi Avval A, Shahbazi Z, Kasani K, Bitarafan Rajabi A, Chatterjee S, Oveisi M, Shiri I, Zaidi H. Myocardial Function Prediction After Coronary Artery Bypass Grafting Using MRI Radiomic Features and Machine Learning Algorithms. J Digit Imaging 2022; 35:1708-1718. [PMID: 35995896 DOI: 10.1007/s10278-022-00681-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 06/21/2022] [Accepted: 07/12/2022] [Indexed: 01/02/2023] Open
Abstract
The main aim of the present study was to predict myocardial function improvement in cardiac MR (LGE-CMR) images in patients after coronary artery bypass grafting (CABG) using radiomics and machine learning algorithms. Altogether, 43 patients who had visible scars on short-axis LGE-CMR images and were candidates for CABG surgery were selected and enrolled in this study. MR imaging was performed preoperatively using a 1.5-T MRI scanner. All images were segmented by two expert radiologists (in consensus). Prior to extraction of radiomics features, all MR images were resampled to an isotropic voxel size of 1.8 × 1.8 × 1.8 mm3. Subsequently, intensities were quantized to 64 discretized gray levels and a total of 93 features were extracted. The applied algorithms included a smoothly clipped absolute deviation (SCAD)-penalized support vector machine (SVM) and the recursive partitioning (RP) algorithm as a robust classifier for binary classification in this high-dimensional and non-sparse data. All models were validated with repeated fivefold cross-validation and 10,000 bootstrapping resamples. Ten and seven features were selected with SCAD-penalized SVM and RP algorithm, respectively, for CABG responder/non-responder classification. Considering univariate analysis, the GLSZM gray-level non-uniformity-normalized feature achieved the best performance (AUC: 0.62, 95% CI: 0.53-0.76) with SCAD-penalized SVM. Regarding multivariable modeling, SCAD-penalized SVM obtained an AUC of 0.784 (95% CI: 0.64-0.92), whereas the RP algorithm achieved an AUC of 0.654 (95% CI: 0.50-0.82). In conclusion, different radiomics texture features alone or combined in multivariate analysis using machine learning algorithms provide prognostic information regarding myocardial function in patients after CABG.
Collapse
Affiliation(s)
- Fatemeh Arian
- Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Mehdi Amini
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4, CH-1211, Switzerland
| | - Shayan Mostafaei
- Division of Clinical Geriatrics, Department of Neurobiology, Care Sciences and Society, Karolinska Institutet, Stockholm, Sweden
| | - Kiara Rezaei Kalantari
- Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran.,Cardio-Oncology Research Center, Rajaei Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | | | - Zahra Shahbazi
- Department of Biostatistics, School of Health, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Kianosh Kasani
- Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran
| | - Ahmad Bitarafan Rajabi
- Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran. .,Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran. .,Echocardiography Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran. .,Cardiovascular interventional research center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.
| | - Saikat Chatterjee
- School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, Brinellvägen 8, Stockholm, Sweden
| | - Mehrdad Oveisi
- Comprehensive Cancer Centre, School of Cancer & Pharmaceutical Sciences, Faculty of Life Sciences & Medicine, Kings College London, London, UK.,Department of Computer Science, University of British Columbia, Vancouver BC, Canada
| | - Isaac Shiri
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4, CH-1211, Switzerland.
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4, CH-1211, Switzerland. .,Geneva University Neurocenter, Geneva University, Geneva, Switzerland. .,Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, Netherlands. .,Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark.
| |
Collapse
|
4
|
Corianò M, Tona F. Strategies for Sudden Cardiac Death Prevention. Biomedicines 2022; 10:biomedicines10030639. [PMID: 35327441 PMCID: PMC8944952 DOI: 10.3390/biomedicines10030639] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 03/06/2022] [Accepted: 03/06/2022] [Indexed: 12/12/2022] Open
Abstract
Sudden cardiac death (SCD) represents a major challenge in modern medicine. The prevention of SCD orbits on two levels, the general population level and individual level. Much research has been done with the aim to improve risk stratification of SCD, although no radical changes in evidence and in therapeutic strategy have been achieved. Artificial intelligence (AI), and in particular machine learning (ML) models, represent novel technologic tools that promise to improve predictive ability of fatal arrhythmic events. In this review, firstly, we analyzed the electrophysiological basis and the major clues of SCD prevention at population and individual level; secondly, we reviewed the main research where ML models were used for risk stratification in other field of cardiology, suggesting its potentiality in the field of SCD prevention.
Collapse
|
5
|
Chang S, Han K, Suh YJ, Choi BW. Quality of science and reporting for radiomics in cardiac magnetic resonance imaging studies: a systematic review. Eur Radiol 2022; 32:4361-4373. [PMID: 35230519 DOI: 10.1007/s00330-022-08587-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 12/31/2021] [Accepted: 01/19/2022] [Indexed: 01/06/2023]
Abstract
OBJECTIVES To evaluate the quality of radiomics studies using cardiac magnetic resonance imaging (CMR) according to the radiomics quality score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) guidelines, and the standards defined by the Image Biomarker Standardization Initiative (IBSI) and identify areas needing improvement. MATERIALS AND METHODS PubMed and Embase were searched to identify radiomics studies using CMR until March 10, 2021. Of the 259 identified articles, 32 relevant original research articles were included. Studies were scored according to the RQS, TRIPOD guidelines, and IBSI standards by two cardiac radiologists. RESULTS The mean RQS was 14.3% of the maximum (5.16 out of 36). RQS were low for the demonstration of validation (-60.6%), calibration statistics (1.6%), potential clinical utility (3.1%), and open science (3.1%) items. No study conducted a phantom study or cost-effectiveness analysis. The adherence to TRIPOD guidelines was 55.9%. Studies were deficient in reporting title (3.1%), stating objective in abstract and introduction (6.3% and 9.4%), missing data (0%), discrimination/calibration (3.1%), and how to use the prediction model (3.1%). According to the IBSI standards, non-uniformity correction, image interpolation, grey-level discretization, and signal intensity normalization were performed in two (6.3%), four (12.5%), six (18.8%), and twelve (37.5%) studies, respectively. CONCLUSION The quality of radiomics studies using CMR is suboptimal. Improvements are needed in the areas of validation, calibration, clinical utility, and open science. Complete reporting of study objectives, missing data, discrimination/calibration, how to use the prediction model, and preprocessing steps are necessary. KEY POINTS • The quality of science in radiomics studies using CMR is currently inadequate. • RQS were low for validation, calibration, clinical utility, and open science; no study conducted a phantom study or cost-effectiveness analysis. • In stating the study objective, missing data, discrimination/calibration, how to use the prediction model, and preprocessing steps, improvements are needed.
Collapse
Affiliation(s)
- Suyon Chang
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Kyunghwa Han
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Young Joo Suh
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
| | - Byoung Wook Choi
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| |
Collapse
|
6
|
Radiomics in Cardiovascular Disease Imaging: from Pixels to the Heart of the Problem. CURRENT CARDIOVASCULAR IMAGING REPORTS 2022. [DOI: 10.1007/s12410-022-09563-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Abstract
Purpose of Review
This review of the literature aims to present potential applications of radiomics in cardiovascular radiology and, in particular, in cardiac imaging.
Recent Findings
Radiomics and machine learning represent a technological innovation which may be used to extract and analyze quantitative features from medical images. They aid in detecting hidden pattern in medical data, possibly leading to new insights in pathophysiology of different medical conditions. In the recent literature, radiomics and machine learning have been investigated for numerous potential applications in cardiovascular imaging. They have been proposed to improve image acquisition and reconstruction, for anatomical structure automated segmentation or automated characterization of cardiologic diseases.
Summary
The number of applications for radiomics and machine learning is continuing to rise, even though methodological and implementation issues still limit their use in daily practice. In the long term, they may have a positive impact in patient management.
Collapse
|
7
|
Virtual Monoenergetic Images of Dual-Energy CT-Impact on Repeatability, Reproducibility, and Classification in Radiomics. Cancers (Basel) 2021; 13:cancers13184710. [PMID: 34572937 PMCID: PMC8467875 DOI: 10.3390/cancers13184710] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 09/14/2021] [Accepted: 09/17/2021] [Indexed: 01/06/2023] Open
Abstract
Simple Summary Virtual monoenergetic images from dual-energy CT are incrementally used in routine clinical practice. Thus, radiomic analysis will be more often performed on these images in the future. This study characterized the test–retest repeatability and reproducibility of radiomic features from virtual monoenergetic images and their impact on machine-learning-based lesion classification. The results of this study provide a basis to improve radiomic analyses and identify the role of feature stability in classification tasks when using virtual monoenergetic imaging with different scan or reconstruction parameters in multicenter clinical studies. Abstract The purpose of this study was to (i) evaluate the test–retest repeatability and reproducibility of radiomic features in virtual monoenergetic images (VMI) from dual-energy CT (DECT) depending on VMI energy (40, 50, 75, 120, 190 keV), radiation dose (5 and 15 mGy), and DECT approach (dual-source and split-filter DECT) in a phantom (ex vivo), and (ii) to assess the impact of VMI energy and feature repeatability on machine-learning-based classification in vivo in 72 patients with 72 hypodense liver lesions. Feature repeatability and reproducibility were determined by concordance–correlation–coefficient (CCC) and dynamic range (DR) ≥0.9. Test–retest repeatability was high within the same VMI energies and scan conditions (percentage of repeatable features ranging from 74% for SFDE mode at 40 keV and 15 mGy to 86% for DSDE at 190 keV and 15 mGy), while reproducibility varied substantially across different VMI energies and DECTs (percentage of reproducible features ranging from 32.8% for SFDE at 5 mGy comparing 40 with 190 keV to 99.2% for DSDE at 15 mGy comparing 40 with 50 keV). No major differences were observed between the two radiation doses (<10%) in all pair-wise comparisons. In vivo, machine learning classification using penalized regression and random forests resulted in the best discrimination of hemangiomas and metastases at low-energy VMI (40 keV), and for cysts at high-energy VMI (120 keV). Feature selection based on feature repeatability did not improve classification performance. Our results demonstrate the high repeatability of radiomics features when keeping scan and reconstruction conditions constant. Reproducibility diminished when using different VMI energies or DECT approaches. The choice of optimal VMI energy improved lesion classification in vivo and should hence be adapted to the specific task.
Collapse
|
8
|
Sartoretti E, Sartoretti T, Wyss M, Reischauer C, van Smoorenburg L, Binkert CA, Sartoretti-Schefer S, Mannil M. Amide proton transfer weighted (APTw) imaging based radiomics allows for the differentiation of gliomas from metastases. Sci Rep 2021; 11:5506. [PMID: 33750899 PMCID: PMC7943598 DOI: 10.1038/s41598-021-85168-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Accepted: 02/24/2021] [Indexed: 12/13/2022] Open
Abstract
We sought to evaluate the utility of radiomics for Amide Proton Transfer weighted (APTw) imaging by assessing its value in differentiating brain metastases from high- and low grade glial brain tumors. We retrospectively identified 48 treatment-naïve patients (10 WHO grade 2, 1 WHO grade 3, 10 WHO grade 4 primary glial brain tumors and 27 metastases) with either primary glial brain tumors or metastases who had undergone APTw MR imaging. After image analysis with radiomics feature extraction and post-processing, machine learning algorithms (multilayer perceptron machine learning algorithm; random forest classifier) with stratified tenfold cross validation were trained on features and were used to differentiate the brain neoplasms. The multilayer perceptron achieved an AUC of 0.836 (receiver operating characteristic curve) in differentiating primary glial brain tumors from metastases. The random forest classifier achieved an AUC of 0.868 in differentiating WHO grade 4 from WHO grade 2/3 primary glial brain tumors. For the differentiation of WHO grade 4 tumors from grade 2/3 tumors and metastases an average AUC of 0.797 was achieved. Our results indicate that the use of radiomics for APTw imaging is feasible and the differentiation of primary glial brain tumors from metastases is achievable with a high degree of accuracy.
Collapse
Affiliation(s)
- Elisabeth Sartoretti
- Institute of Radiology, Kantonsspital Winterthur, Winterthur, Switzerland.,Faculty of Medicine, University of Zürich, Zürich, Switzerland
| | - Thomas Sartoretti
- Institute of Radiology, Kantonsspital Winterthur, Winterthur, Switzerland.,Faculty of Medicine, University of Zürich, Zürich, Switzerland
| | - Michael Wyss
- Institute of Radiology, Kantonsspital Winterthur, Winterthur, Switzerland.,Philips Healthsystems, Zürich, Switzerland
| | - Carolin Reischauer
- Department of Medicine, University of Fribourg, Fribourg, Switzerland.,Department of Radiology, HFR Fribourg-Hôpital Cantonal, Fribourg, Switzerland
| | | | | | | | - Manoj Mannil
- Department of Neuroradiology, Kantonsspital Aarau, Aarau, Switzerland. .,Institute of Clinical Radiology, University Hospital Münster, University of Münster, Albrecht-Schweitzer-Campus 1, E48149, Münster, Germany.
| |
Collapse
|