1
|
Fiorin L, Poole SF, Oliveira PEBS, Faria ACL, Ribeiro RF, Rodrigues RCS. Effect of Staining, Glazing and Polishing on the Survival Probability of Monolithic Zirconia Crowns. J ESTHET RESTOR DENT 2025; 37:485-495. [PMID: 39228147 DOI: 10.1111/jerd.13310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 08/16/2024] [Accepted: 08/19/2024] [Indexed: 09/05/2024]
Abstract
OBJECTIVE The purpose of this in vitro study was to evaluate the effect of staining, glazing, and polishing on the survival probability of monolithic crowns manufactured with preshaded stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP). MATERIALS AND METHODS Monolithic crowns in the shape of an upper canine (1.5 mm of thickness) were manufactured by CAD/CAM, adhesively cemented on metallic foundation, and divided into 6 groups (n = 21): C (control), S (staining), G (glazing), P (polishing), SG (staining and glazing), and SP (staining and polishing). The survival probability was determined by step-stress accelerated life testing with a load applied to the palatine concavity of the crown. First, the specimens were subjected to a single-load to fracture test (SLF) and next to the fatigue test (5 Hz, thermocycling immersed in water varying 5-55°C), including the light (n = 9), moderate (n = 6), and aggressive (n = 3) loading profiles (load ranged between 20% and 60% of SLF). The survival probability was calculated considering the cycles for failure (CFF) and fatigue failure load (FFL) and illustrated using a Kaplan-Meier graph. The comparison among groups was performed using a Log-Rank test (α = 0.05). RESULTS The mean value of SLF was 586.7 N. There was no difference among groups in survival probability, considering CFF and FFL. CONCLUSION Staining, glazing, and polishing can be performed safely without damaging the mechanical behavior of 5Y-TZP monolithic crowns. CLINICAL SIGNIFICANCE Staining is used to characterize and improve the esthetic of zirconia monolithic crowns. It can be used to reproduce the color gradient in the cervical region of the crown and pigmented grooves. This study showed that staining, glazing, and polishing did not affect the survival probability and the use of finishing procedures (glazing or polishing) after staining did not improve the survival probability of zirconia monolithic crowns.
Collapse
Affiliation(s)
- Lívia Fiorin
- Department of Dental Materials and Prostheses, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), São Paulo, Brazil
| | - Stephanie Francoi Poole
- Department of Dental Materials and Prostheses, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), São Paulo, Brazil
| | | | - Adriana Claudia Lapria Faria
- Department of Dental Materials and Prostheses, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), São Paulo, Brazil
| | - Ricardo Faria Ribeiro
- Department of Dental Materials and Prostheses, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), São Paulo, Brazil
| | | |
Collapse
|
2
|
Fiorin L, Oliveira PEBS, Poole SF, Faria ACL, Ribeiro RF, Rodrigues RCS. In Vitro Wear of Human Enamel Against Monolithic Zirconia After Staining, Glazing and Polishing Treatments. J ESTHET RESTOR DENT 2024. [PMID: 39542646 DOI: 10.1111/jerd.13367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 10/17/2024] [Accepted: 11/03/2024] [Indexed: 11/17/2024]
Abstract
OBJECTIVE To evaluate the effect of staining, glazing, and polishing of stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP) on the wear behavior of opposing tooth enamel. MATERIALS AND METHODS The plane specimens of 5Y-TZP were divided into 6 groups (n = 10), according to surface treatment: as sintered, staining, glazing, polishing, staining followed by glazing, and staining followed by polishing, and positioned against tooth enamel during the two-body wear test (20 N, 2 Hz, until completing 300,000 cycles). The wear rates of tooth enamel were evaluated using a profile projector and a digital pachymeter as a measure of vertical height loss. The data were analyzed by one-way ANOVA and a Tukey post hoc test (α = 0.05). RESULTS Polishing reduced the vertical height loss (p < 0.001) while there was no difference among other groups. CONCLUSION Polishing is recommended as a finishing procedure to reduce the wear rates of tooth enamel, and finishing procedures (glazing or polishing) performed after staining did not affect the vertical height loss of tooth enamel. CLINICAL SIGNIFICANCE Polishing is the recommended finishing procedure for preshaded 5Y-TZP to reduce the wear rates of opposing tooth enamel. Staining is applied to the occlusal surface to reproduce the pigmented groove appearance, and glazing or polishing performed after staining did not affect the wear rates of opposing tooth enamel.
Collapse
Affiliation(s)
- Lívia Fiorin
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirao Preto, University of São Paulo (USP), São Paulo, Brazil
| | | | - Stephanie Francoi Poole
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirao Preto, University of São Paulo (USP), São Paulo, Brazil
| | - Adriana Claudia Lapria Faria
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirao Preto, University of São Paulo (USP), São Paulo, Brazil
| | - Ricardo Faria Ribeiro
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirao Preto, University of São Paulo (USP), São Paulo, Brazil
| | | |
Collapse
|
3
|
Jeong JI, Kwon YH, Seol HJ. In Vitro Evaluation of Speed Sintering and Glazing Effects on the Flexural Strength and Microstructure of Highly Translucent Multilayered 5 mol% Yttria-Stabilized Zirconia. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4634. [PMID: 39336375 PMCID: PMC11433405 DOI: 10.3390/ma17184634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2024] [Revised: 09/11/2024] [Accepted: 09/18/2024] [Indexed: 09/30/2024]
Abstract
This study aimed to investigate the impact of speed sintering and glazing on the flexural strength and microstructure of multilayered 5 mol% yttria-stabilized (5Y-) zirconia, which remains unknown. Bar-shaped specimens (N = 600) were fabricated from 5Y-zirconia (FX; Ceramill Zolid FX ML, ST; Katana STML) by cutting, polishing, sintering (conventional and speed sintering), and then glazing. A flexural strength test (n = 30/group), field emission scanning electron microscopy (FE-SEM) observation (n = 2/group), and an X-ray diffraction (XRD) study with Rietveld refinement (n = 1/group) were performed. The flexural strength was analyzed using three-way ANOVA and a post hoc Scheffé test. The grain size was analyzed using the Kruskal-Wallis H test and Bonferroni-Dunn post hoc test. Flexural strength slightly decreased in the nonglazed FX after speed sintering (p < 0.05). Glazing with and without glazing paste did not affect flexural strength at both sintering speeds (p > 0.05). Speed sintering and glazing minimally changed the Weibull modulus and phase fraction, and did not affect grain size (p > 0.05). ST had a larger grain size and lower tetragonal phase content than FX and had a lower flexural strength than FX in most groups (p < 0.05). Overall, the multilayered 5Y-zirconia is considered suitable for dental application using speed sintering and glazing.
Collapse
Affiliation(s)
- Ji-In Jeong
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan-si 626-814, Republic of Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan-si 626-814, Republic of Korea
| | - Hyo-Joung Seol
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan-si 626-814, Republic of Korea
| |
Collapse
|
4
|
Kang CM, Hsu WC, Chen MS, Wu HY, Mine Y, Peng TY. Fracture characteristics and translucency of multilayer monolithic zirconia crowns of various thicknesses. J Dent 2024; 145:105023. [PMID: 38670331 DOI: 10.1016/j.jdent.2024.105023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 04/22/2024] [Accepted: 04/23/2024] [Indexed: 04/28/2024] Open
Abstract
OBJECTIVES Multilayer monolithic zirconia (M-Zr) crowns can be engineered to achieve gradational translucency and color intensity. However, this modification may compromise the mechanical strength, raising concerns regarding the ability of M-Zr crowns to withstand occlusal stresses. The effects of M-Zr crown thickness on translucency and ability to endure occlusal forces were investigated at different tooth positions (incisors, premolars, and molars). The objective was to determine the minimal thickness of M-Zr crowns used in tooth preparation to meet aesthetic and functional demands. METHODS M-Zr samples (Vita A1) with four thicknesses (0.5, 1.0, 1.5, and 2.0 mm) were prepared and subjected to translucency testing using a digital colorimeter by 3-third and 9-square division methods. Crown-shaped M-Zr samples with three thicknesses (1.0, 1.5, and 2.0 mm) and three tooth positions (incisor, premolar, and molar) were digitally designed, and 2.0 mm metal abutments were fabricated. The samples were bonded to the abutments; their fracture characteristics were evaluated using a universal testing machine, and their fracture surfaces examined using an optical microscope. Statistical analyses included the Shapiro-Wilk test, Pearson correlation, and one-way and two-way ANOVA with a post hoc Tukey HSD test (α = 0.05). RESULTS Color analysis results revealed a significant negative correlation between thickness and translucency (r < -0.96, P < 0.01), with the highest values in the incisal region. Cross-sectional profiles confirmed the uniform thickness and morphology of the digitally designed M-Zr crowns. The results of fracture strength analysis showed position-dependent variability, a strong positive correlation with thickness (r > 0.96, P < 0.01), and fracture strengths consistently exceeding 1200 N across all tooth positions. Fracture patterns indicated that thinner crowns at the incisors and molars were more prone to cracking, whereas those at the premolars demonstrated significantly higher strength (4872.51 N, P < 0.05), only with crack or even no fracture occurring at 2.0 mm. CONCLUSIONS Thickness significantly influenced both the translucency and fracture strength of M-Zr, with the tooth position playing an additional role, albeit to a lesser extent. Although thinner crowns exhibited lower strength at each tooth position, even at a thickness of 1.0 mm, fracture strength exceeding 1200 N was maintained, surpassing the typical occlusal forces. Thus, it can be asserted that M-Zr crowns with a minimum thickness of 1.0 mm can meet both aesthetic and functional requirements.
Collapse
Affiliation(s)
- Chien-Ming Kang
- Huayi Dental Laboratory, Taipei, Taiwan; School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Wen-Chieh Hsu
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan; Department of Oral Hygiene, Hsin Sheng Junior College of Medical Care and Management, Taoyuan, Taiwan; Research Center of Precision Biomedical Implants, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - May-Show Chen
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan; Division of Prosthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, Taiwan
| | - Hsuan-Yu Wu
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Yuichi Mine
- Department of Medical Systems Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan; Project Research Center for Integrating Digital Dentistry, Hiroshima University, Hiroshima, Japan
| | - Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
| |
Collapse
|
5
|
Branco AC, Santos T, Bessa LJ, Barahona I, Polido M, Colaço R, Serro AP, Figueiredo-Pina CG. Optimized 3D printed zirconia-reinforced leucite with antibacterial coating for dental applications. Dent Mater 2024; 40:629-642. [PMID: 38369404 DOI: 10.1016/j.dental.2024.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/17/2024] [Accepted: 02/12/2024] [Indexed: 02/20/2024]
Abstract
OBJECTIVES This study aims to produce by robocasting leucite/zirconia pieces with suitable mechanical and tribological performance, convenient aesthetics, and antibacterial properties to be used in dental crown replacement. METHODS Leucite pastes reinforced with 12.5%, 25%, and 37.5% wt. ZrO2 nanoparticles were prepared and used to print samples that after sintering were characterized in terms of density, shrinkage, morphology, porosity, mechanical and tribological properties and translucency. A coating of silver diamine fluoride (SDF) and potassium iodide (KI) was applied over the most promising material. The material's antibacterial activity and cytotoxicity were assessed. RESULTS It was found that the increase of ZrO2 reinforcement up to 25% enhanced both microhardness and fracture toughness of the sintered composite. However, for a superior content of ZrO2, the increase of the porosity negatively affected the mechanical behaviour of the composite. Moreover, the composite with 25% ZrO2 exhibited neglectable wear in chewing simulator tests and induced the lowest wear on the antagonist dental cusps. Although this composite exhibited lower translucency than human teeth, it was three times higher than the ZrO2 glazed material. Coating this composite material with SDF+KI conferred antibacterial properties without inducing cytotoxicity. SIGNIFICANCE Robocasting of leucite reinforced with 25% ZrO2 led to best results. The obtained material revealed superior optical properties and tribomechanical behaviour compared to glazed ZrO2 (that is a common option in dental practice). Moreover, the application of SDF+KI coating impaired S. aureus proliferation, which anticipates its potential benefit for preventing pathogenic bacterial complications associated with prosthetic crown placement.
Collapse
Affiliation(s)
- A C Branco
- CQE, Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; CDP2T, Centro de Desenvolvimento de Produto e Transferência de Tecnologia, Escola Superior de Tecnologia de Setúbal, Instituto Politécnico de Setúbal, Setúbal, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | | | - L J Bessa
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - I Barahona
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - M Polido
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - R Colaço
- IDMEC e Departamento de Engenharia Mecânica, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - A P Serro
- CQE, Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal.
| | - C G Figueiredo-Pina
- CDP2T, Centro de Desenvolvimento de Produto e Transferência de Tecnologia, Escola Superior de Tecnologia de Setúbal, Instituto Politécnico de Setúbal, Setúbal, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal; CeFEMA, Centro de Física e Engenharia de Materiais Avançados, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
6
|
Chen PH, Elamin E, Sayed Ahmed A, Givan DA, Fu CC, Lawson NC. The Effect of Restoration Thickness on the Fracture Resistance of 5 mol% Yttria-Containing Zirconia Crowns. MATERIALS (BASEL, SWITZERLAND) 2024; 17:365. [PMID: 38255531 PMCID: PMC10817558 DOI: 10.3390/ma17020365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/04/2024] [Accepted: 01/08/2024] [Indexed: 01/24/2024]
Abstract
BACKGROUND To determine what thickness of 5 mol% yttria zirconia (5Y-Z) translucent crowns cemented with different cements and surface treatments would have equivalent fracture resistance as 3 mol% yttria (3Y-Z) crowns. METHODS The study included 0.8 mm, 1.0 mm, and 1.2 mm thickness 5Y-Z (Katana UTML) crowns and 0.5 and 1.0 mm thickness 3Y-Z (Katana HT) crowns as controls. The 5Y-Z crowns were divided among three treatment subgroups (n = 10/subgroup): (1) cemented using RMGIC (Rely X Luting Cement), (2) alumina particle-abraded then luted with the same cement, (3) alumina particle-abraded and cemented using a resin cement (Panavia SA Cement Universal). The 3Y-Z controls were alumina particle-abraded then cemented with RMGIC. The specimens were then loaded in compression at 30° until failure. RESULTS All 5Y-Z crowns (regardless of thickness or surface treatment) had a similar to or higher fracture force than the 0.5 mm 3Y-Z crowns. Only the 1.2 mm 5Y-Z crowns with resin cement showed significantly similar fracture force to the 1 mm 3Y-Z crowns. CONCLUSION In order to achieve a similar fracture resistance to 0.5 mm 3Y-Z crowns cemented with RMGIC, 5Y-Z crowns may be as thin as 0.8 mm. To achieve a similar fracture resistance to 1.0 mm 3Y-Z crowns cemented with RMGIC, 5Y-Z crowns must be 1.2 mm and bonded with resin cement.
Collapse
Affiliation(s)
- Po-Hsu Chen
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| | - Esra Elamin
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| | - Akram Sayed Ahmed
- Faculty of Dentistry, Department of Dental Biomaterials, Tanta University, Tanta 31527, Egypt;
| | - Daniel A. Givan
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| | - Chin-Chuan Fu
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| | - Nathaniel C. Lawson
- Division of Prosthodontics, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35209, USA; (P.-H.C.); (E.E.); (D.A.G.); (C.-C.F.)
| |
Collapse
|
7
|
Kui A, Manziuc M, Petruțiu A, Buduru S, Labuneț A, Negucioiu M, Chisnoiu A. Translucent Zirconia in Fixed Prosthodontics-An Integrative Overview. Biomedicines 2023; 11:3116. [PMID: 38137337 PMCID: PMC10740999 DOI: 10.3390/biomedicines11123116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/12/2023] [Accepted: 11/15/2023] [Indexed: 12/24/2023] Open
Abstract
Over the past two decades, dental ceramics have experienced rapid advances in science and technology, becoming the fastest-growing field of dental materials. This review emphasizes the significant impact of translucent zirconia in fixed prosthodontics, merging aesthetics with strength, and highlights its versatility from single crowns to complex bridgework facilitated by digital manufacturing advancements. The unique light-conducting properties of translucent zirconia offer a natural dental appearance, though with considerations regarding strength trade-offs compared to its traditional, opaque counterpart. The analysis extends to the mechanical attributes of the material, noting its commendable fracture resistance and durability, even under simulated physiological conditions. Various zirconia types (3Y-TZP, 4Y-TZP, 5Y-TZP) display a range of strengths influenced by factors like yttria content and manufacturing processes. The study also explores adhesive strategies, underlining the importance of surface treatments and modern adhesives in achieving long-lasting bonds. In the realm of implant-supported restorations, translucent zirconia stands out for its precision, reliability, and aesthetic adaptability, proving suitable for comprehensive dental restorations. Despite its established benefits, the review calls for ongoing research to further refine the material's properties and adhesive protocols and to solidify its applicability through long-term clinical evaluations, ensuring its sustainable future in dental restorative applications.
Collapse
Affiliation(s)
- Andreea Kui
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Manuela Manziuc
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Adrian Petruțiu
- Oral Rehabilitation Department, Iuliu Hatieganu University of Medicine and Pharmacy, 13 Victor Babes Street, 400008 Cluj-Napoca, Romania
| | - Smaranda Buduru
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Anca Labuneț
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Marius Negucioiu
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Andrea Chisnoiu
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| |
Collapse
|
8
|
Barreto LAL, Grangeiro MTV, Prado PHCO, Bottino MA, Dal Piva AMDO, Ramos NDC, Tribst JPM, Junior LN. Effect of Finishing Protocols on the Surface Roughness and Fatigue Strength of a High-Translucent Zirconia. Int J Dent 2023; 2023:8882878. [PMID: 37780934 PMCID: PMC10541300 DOI: 10.1155/2023/8882878] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 08/16/2023] [Accepted: 08/29/2023] [Indexed: 10/03/2023] Open
Abstract
Purpose In case of need for esthetical improvement of zirconia restorations, an individualization using extrinsic staining can be applied. This study aimed to evaluate the surface roughness and fatigue strength (survival) of high-translucency zirconia (3Y-TZP, YZ®HT, Vita Zanhfabrik) with extrinsic characterization and/or glaze. Methods Sixty (60) zirconia discs (12 × 1.2 mm) were obtained, sintered, and randomly distributed among three groups (n = 20) according to the surface finishing protocol: C (control), C + G (extrinsic characterization followed by a glaze layer), and G (glaze layer). The surface roughness (Ra) was analyzed with a contact profilometer. Subsequently, the specimens were subjected to a fatigue load profile starting at 120 N during 20,000 cycles at 4 Hz frequency, with a 5% increase at each step until failure. The failed specimens were evaluated under a stereomicroscope. Surface roughness analysis was evaluated by using one-way ANOVA and post hoc Tukey tests (95%); while fatigue survival probability was analyzed with Kaplan-Meier and Mantel-Cox (log- rank, 95%). Results One-way ANOVA revealed that surface roughness was affected by the finishing protocol, where C + G showed the highest mean value (0.46 ± 0.18 µm)A followed by G (0.30 ± 0.10 µm)B, and C (0.19 ± 0.02 µm)C. While for fatigue strength, the G protocol presented a higher mean value (243.00, and 222.36-263.63)A, followed by C + G (192.75 and 186.61-198.88)B and C (172.50 and 159.43-185.56)C. Conclusion Surface finishing protocols modify the surface roughness and fatigue strength of high-translucent zirconia. Regardless of the surface roughness, both glazing protocols improved the ceramic fatigue strength, favoring the restoration's long-term survival.
Collapse
Affiliation(s)
- Larissa Araújo Lopes Barreto
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - Manassés Tercio Vieira Grangeiro
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - Pedro Henrique Condé Oliveira Prado
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Netherlands
| | - Nathalia de Carvalho Ramos
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Netherlands
| | - Lafayette Nogueira Junior
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), Eng. Francisco José Longo Avenue, 777, São José dos Campos, SP, Brazil
| |
Collapse
|