1
|
Fan W, Dong Y, Ren W, Liu C. Single microentity analysis-based ultrasensitive bioassays: Recent advances, applications, and perspectives. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
|
2
|
Fan W, Ren W, Liu C. Advances in optical counting and imaging of micro/nano single-entity reactors for biomolecular analysis. Anal Bioanal Chem 2023; 415:97-117. [PMID: 36322160 PMCID: PMC9628437 DOI: 10.1007/s00216-022-04395-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 10/14/2022] [Accepted: 10/19/2022] [Indexed: 11/07/2022]
Abstract
Ultrasensitive detection of biomarkers is of paramount importance in various fields. Superior to the conventional ensemble measurement-based assays, single-entity assays, especially single-entity detection-based digital assays, not only can reach ultrahigh sensitivity, but also possess the potential to examine the heterogeneities among the individual target molecules within a population. In this review, we summarized the current biomolecular analysis methods that based on optical counting and imaging of the micro/nano-sized single entities that act as the individual reactors (e.g., micro-/nanoparticles, microemulsions, and microwells). We categorize the corresponding techniques as analog and digital single-entity assays and provide detailed information such as the design principles, the analytical performance, and their implementation in biomarker analysis in this work. We have also set critical comments on each technique from these aspects. At last, we reflect on the advantages and limitations of the optical single-entity counting and imaging methods for biomolecular assay and highlight future opportunities in this field.
Collapse
Affiliation(s)
- Wenjiao Fan
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Xi’an, 710119 Shaanxi Province People’s Republic of China ,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, Xi’an, 710119 Shaanxi Province People’s Republic of China ,School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi’an, 710119 Shaanxi Province People’s Republic of China
| | - Wei Ren
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Xi’an, 710119 Shaanxi Province People’s Republic of China ,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, Xi’an, 710119 Shaanxi Province People’s Republic of China ,School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi’an, 710119 Shaanxi Province People’s Republic of China
| | - Chenghui Liu
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Xi’an, 710119 Shaanxi Province People’s Republic of China ,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, Xi’an, 710119 Shaanxi Province People’s Republic of China ,School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi’an, 710119 Shaanxi Province People’s Republic of China
| |
Collapse
|
3
|
Dorfman KD, King SB, Olson DW, Thomas JDP, Tree DR. Beyond gel electrophoresis: microfluidic separations, fluorescence burst analysis, and DNA stretching. Chem Rev 2013; 113:2584-667. [PMID: 23140825 PMCID: PMC3595390 DOI: 10.1021/cr3002142] [Citation(s) in RCA: 141] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Kevin D. Dorfman
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| | - Scott B. King
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| | - Daniel W. Olson
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| | - Joel D. P. Thomas
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| | - Douglas R. Tree
- Department of Chemical Engineering and Materials Science, University of Minnesota — Twin Cities, 421 Washington Ave. SE, Minneapolis, MN 55455, Phone: 1-612-624-5560. Fax: 1-612-626-7246
| |
Collapse
|
4
|
Kim SH, Iwai S, Araki S, Sakakihara S, Iino R, Noji H. Large-scale femtoliter droplet array for digital counting of single biomolecules. LAB ON A CHIP 2012; 12:4986-91. [PMID: 22961607 DOI: 10.1039/c2lc40632b] [Citation(s) in RCA: 141] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
We present a novel device employing one million femtoliter droplets immobilized on a substrate for the quantitative detection of extremely low concentrations of biomolecules in a sample. Surface-modified polystyrene beads carrying either zero or a single biomolecule-reporter enzyme complex are efficiently isolated into femtoliter droplets formed on hydrophilic-in-hydrophobic surfaces. Using a conventional micropipette, this is achieved by sequential injection first with an aqueous solution containing beads, and then with fluorinated oil. The concentration of target biomolecules is estimated from the ratio of the number of signal-emitting droplets to the total number of trapped beads (digital counting). The performance of our digital counting device was demonstrated by detecting a streptavidin-β-galactosidase conjugate with a limit of detection (LOD) of 10 zM. The sensitivity of our device was >20-fold higher than that noted in previous studies where a smaller number of reactors (fifty thousand reactors) were used. Such a low LOD was achieved because of the large number of droplets in an array, allowing simultaneous examination of a large number of beads. When combined with bead-based enzyme-linked immunosorbent assay (digital ELISA), the LOD for the detection of prostate specific antigen reached 2 aM. This value, again, was improved over that noted in a previous study, because of the decreased coefficient of variance of the background measurement determined by the Poisson noise. Our digital counting device using one million droplets has great potential as a highly sensitive, portable immunoassay device that could be used to diagnose diseases.
Collapse
Affiliation(s)
- Soo Hyeon Kim
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-8656, Japan
| | | | | | | | | | | |
Collapse
|
5
|
Liu C, Qu Y, Luo Y, Fang N. Recent advances in single-molecule detection on micro- and nano-fluidic devices. Electrophoresis 2012; 32:3308-18. [PMID: 22134976 DOI: 10.1002/elps.201100159] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Single-molecule detection (SMD) allows static and dynamic heterogeneities from seemingly equal molecules to be revealed in the studies of molecular structures and intra- and inter-molecular interactions. Micro- and nanometer-sized structures, including channels, chambers, droplets, etc., in microfluidic and nanofluidic devices allow diffusion-controlled reactions to be accelerated and provide high signal-to-noise ratio for optical signals. These two active research frontiers have been combined to provide unprecedented capabilities for chemical and biological studies. This review summarizes the advances of SMD performed on microfluidic and nanofluidic devices published in the past five years. The latest developments on optical SMD methods, microfluidic SMD platforms, and on-chip SMD applications are discussed herein and future development directions are also envisioned.
Collapse
Affiliation(s)
- Chang Liu
- Ames Laboratory, US Department of Energy, Ames, Iowa, USA
| | | | | | | |
Collapse
|
6
|
Zhao H. Role of hydrodynamic behavior of DNA molecules in dielectrophoretic polarization under the action of an electric field. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2011; 84:021910. [PMID: 21929023 DOI: 10.1103/physreve.84.021910] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2011] [Revised: 06/23/2011] [Indexed: 05/31/2023]
Abstract
A continuum model is developed to predict the dielectrophoretic polarizability of coiled DNA molecules under the action of an alternating current electric field. The model approximates the coiled DNA molecule as a charged porous spherical particle. The model explains the discrepancies among scaling laws of polarizability of different-sized DNA molecules with contour length and such discrepancies are attributed to different hydrodynamic behavior. With zero or one fitting parameter, theoretical predictions are in good agreement with various experimental data, even though in experiments there are some uncertainties in regard to certain parameters.
Collapse
Affiliation(s)
- Hui Zhao
- Department of Mechanical Engineering, University of Nevada Las Vegas, Las Vegas, Nevada 89154, USA.
| |
Collapse
|
7
|
Sakakihara S, Araki S, Iino R, Noji H. A single-molecule enzymatic assay in a directly accessible femtoliter droplet array. LAB ON A CHIP 2010; 10:3355-62. [PMID: 21031171 DOI: 10.1039/c0lc00062k] [Citation(s) in RCA: 91] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The enzyme assay in a femtoliter chamber array is a simple and efficient method for concentrating the reaction product; it greatly improves the detection sensitivity down to the single-molecule level. However, in previous methods, controlling the initiation and termination of the reaction in each chamber is difficult once enclosed. Furthermore, the recovery of the enzyme and product is also difficult. To overcome these drawbacks, we developed a femtoliter droplet array in which the individual droplets are fixed on the substrate and are directly accessible from outside. A hydrophilic-in-hydrophobic micropatterned surface was used for the preparation of the droplets. When the aqueous solution on the surface is exchanged with oil, the hydrophilic surface retains the aqueous solution, and more than 10(6) dome-shaped droplets that are usable for further assay can be prepared simultaneously. The curvature radius of the droplet obeys the Young-Laplace equation, and the volume can be precisely controlled by the micropipette, which applies pressure into the droplet. Changing the pressure makes the addition, collection, and exchange of the aqueous content for individual droplets possible. Using these advantages, we successfully measured the kinetic parameters of the single-molecule enzyme β-galactosidase and rotary motor protein F(1)-ATPase enclosed in a droplet.
Collapse
Affiliation(s)
- Shouichi Sakakihara
- Institute of Scientific and Industrial Research, Osaka University, Mihogaoka, 8-1, Ibaraki, Osaka 567-0047, Japan
| | | | | | | |
Collapse
|
8
|
Kang SH, Lee S, Yeung ES. Digestion of individual DNA molecules by lambda-exonuclease at liquid-solid interface. Analyst 2010; 135:1759-64. [PMID: 20436973 DOI: 10.1039/c0an00145g] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Enzyme digestion of single DNA molecules was directly observed in real time by dual-color total internal reflection fluorescence microscopy (TIRFM). Individual lambda-DNA molecules labeled with the fluorescent dye, YOYO-1, were stretched in a laminar flow stream and immobilized on a bare fused-silica prism surface based on hydrophobic and electrostatic interactions. Enzyme digestion was initiated by the influx of lambda-exonuclease enzyme via capillary force. When the dye : bp ratio was higher than 1 : 20, the exact digestion rate could not be measured because of induced photocleavage of the DNA molecules. At a dye : bp ratio of 1 : 50, shortening of the DNA strand was recorded in real time. Unlike previous studies, the length-based digestion rate of lambda-exonuclease showed 3 distinct values in the range of 0.173(+/-0.024) to 0.462(+/-0.152) microm s(-1) at 37 degrees C. That is, different enzyme molecules exhibit different digestion dynamics. Digestion was also monitored based on the decrease in fluorescence intensity, but uncertainties were much larger due to the distance dependent excitation intensity in the TIRF mode.
Collapse
Affiliation(s)
- Seong Ho Kang
- Ames Laboratory-USDOE and Department of Chemistry, Iowa State University, Ames, Iowa 50011, USA
| | | | | |
Collapse
|
9
|
Abstract
The physical properties of DNA are quite important for molecular genetics as well as for its nanotechnological applications. Studying the interactions of alternating current (AC) electric fields with deoxyribonucleic acid (DNA) allows one to draw conclusions about these properties. These interactions are usually investigated in two different ways. In dielectric spectroscopy, a DNA solution is placed in a homogeneous AC field and electronic parameters are measured over several frequency decades in the Hz to GHz range. These electronic data are then interpreted on the basis of physico-chemical models as a result of certain phenomena on the molecular level. In dielectrophoretic studies, a DNA solution is exposed to an inhomogeneous AC field and the spatial response of few or single molecules is monitored by optical or scanning force microscopy. This response can involve translation, elongation and orientation of the molecular strings. In this review, a survey is given of the literature dealing with the dielectric and dielectrophoretic properties of DNA as well as with applications of DNA dielectrophoresis.
Collapse
Affiliation(s)
- R Hölzel
- Fraunhofer Institute for Biomedical Engineering, Department of Molecular Bioanalytics and Bioelectronics, Potsdam-Golm, Germany.
| |
Collapse
|
10
|
Meighan MM, Staton SJR, Hayes MA. Bioanalytical separations using electric field gradient techniques. Electrophoresis 2009; 30:852-65. [DOI: 10.1002/elps.200800614] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
11
|
Lam L, Iino R, Tabata KV, Noji H. Highly sensitive restriction enzyme assay and analysis: a review. Anal Bioanal Chem 2008; 391:2423-32. [PMID: 18427787 DOI: 10.1007/s00216-008-2099-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2007] [Revised: 02/13/2008] [Accepted: 03/20/2008] [Indexed: 11/27/2022]
Abstract
Biological assays at the single molecule level are crucial to fundamental studies of DNA-protein mechanisms. In order to cater for high throughput applications, one area of immense research potential is single-molecule bioassays where miniaturized devices are developed to perform rapid and effective biological reactions and analyses. With the success of various emerging technologies for engineering miniaturized structures down to the nanoscale level, supported by specialized equipment for detection, many investigations in the field of life science that were once thought impossible can now be actively explored. In this review, the significance of downscaling to the single-molecule level is firstly presented in selected examples, with the focus placed on restriction enzyme assays. To determine the effectiveness of single-molecule restriction enzyme reactions, simple and direct analytical methods based on DNA stretching have often been reliably employed. DNA stretching can be realized based on a number of working principles related to the physical forces exerted on the DNA samples. We then discuss two examples of a nanochannel system and a microchamber system where single-molecule restriction enzyme digestion and DNA stretching have been integrated, which possess prospective capabilities of developing into highly sensitive and high-throughput restriction enzyme assays. Finally, we take a brief look at the general trends in technological development in this field by comparing the advantages and disadvantages of performing assays at bulk, microscale and single-molecule levels.
Collapse
Affiliation(s)
- Liza Lam
- The Institute of Scientific and Industrial Research, Osaka University, Osaka 567-0047, Japan.
| | | | | | | |
Collapse
|