1
|
Mohamed MM, Gamal H, El-Didamony A, Youssef AO, Elshahat E, Mohamed EH, Attia MS. Polymer-Based Terbium Complex as a Fluorescent Probe for Cancer Antigen 125 Detection: A Promising Tool for Early Diagnosis of Ovarian Cancer. ACS OMEGA 2024; 9:24916-24924. [PMID: 38882142 PMCID: PMC11170746 DOI: 10.1021/acsomega.4c01814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 04/30/2024] [Accepted: 05/21/2024] [Indexed: 06/18/2024]
Abstract
A novel photoprobe, Tb-acetylacetone (Tb-ACAC) doped within a modified epoxy cellulose polymer immobilized with CA-125 monoclonal antibody, offers an accurate and highly selective method for early ovarian cancer (OC) diagnosis by detecting cancer antigen 125 (CA-125) in serum samples. This approach leverages quenching of the Tb-ACAC luminescence upon binding to CA-125. Characterization of the photoprobe film through UV-vis and fluorescence measurements confirmed the presence of Tb-ACAC within the polymer matrix. In aqueous solution (pH 6.8, λex = 365 nm), the characteristic emission band of Tb-ACAC at λem = 546.2 nm exhibited significant quenching upon CA-125 binding. This quenching effect enabled the sensitive and specific detection of CA-125 in diverse serum samples from OC patients, demonstrating the applicability, simplicity, and effectiveness of this novel approach.
Collapse
Affiliation(s)
- Magda M Mohamed
- Chemistry Department, Faculty of Science, Ain Shams University, Abbassia, Cairo 11566, Egypt
| | - Hisham Gamal
- Aeromedical Council Laboratories-Ministry of Civil Aviation, Cairo 3753450, Egypt
| | - Akram El-Didamony
- Chemistry Department, Faculty of Science, Zagazig University, Zagazig 44519, Egypt
| | - Ahmed O Youssef
- Chemistry Department, Faculty of Science, Ain Shams University, Abbassia, Cairo 11566, Egypt
| | - Esraa Elshahat
- Clinical Pathology Department, Faculty of Medicine, Ain Sham University, Abbassia, Cairo 11566, Egypt
| | - Ekram H Mohamed
- Pharmaceutical Chemistry Department, Faculty of Pharmacy, The British University in Egypt, El-Sherouk 11837, Egypt
| | - Mohamed S Attia
- Chemistry Department, Faculty of Science, Ain Shams University, Abbassia, Cairo 11566, Egypt
| |
Collapse
|
2
|
Can F, Akkas T, Bekler SY, Takmakli S, Uzun L, Ozaydin Ince G. Selective determination of an ovarian cancer biomarker at low concentrations with surface imprinted nanotube based chemosensor. Bioelectrochemistry 2024; 157:108655. [PMID: 38310811 DOI: 10.1016/j.bioelechem.2024.108655] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 12/14/2023] [Accepted: 01/22/2024] [Indexed: 02/06/2024]
Abstract
In this study, an electrochemical chemosensor that utilizes a conductive polymer-based molecularly imprinted polymer (MIP) surface for rapid and reliable determination of CA125 was devised. A novel method has been applied to fabricate CA125 imprinted polypyrrole nanotubes (MI-PPy NT) via vapor deposition polymerization (VDP) as a recognition element for highly selective and sensitive determination of CA125. The chemosensor was prepared by immobilizing MI-PPy NT onto screen-printed gold electrodes (Au-SPE) and the performance of the sensor was evaluated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in terms of selectivity, sensitivity, linear dynamic concentration range (LDR) and limit of detection (LOD). The MI-PPy NT@Au-SPE sensor exhibited high sensitivity (68.57 μA per decade) to the CA125 concentration ranging from 0.1 U mL-1 to 100 U mL-1 at an LOD of 0.4 U mL-1 with a correlation coefficient of 0.9922. The developed chemosensors with their novel design combined with a facile fabrication method, prove to be promising as future state-of-the-art biosensors.
Collapse
Affiliation(s)
- Faruk Can
- Nanotechnology Research and Application Center (SUNUM), Sabanci University, 34956 Istanbul, Turkiye
| | - Tugce Akkas
- Nanotechnology Research and Application Center (SUNUM), Sabanci University, 34956 Istanbul, Turkiye
| | - Sevinc Yagmur Bekler
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Istanbul, Turkiye
| | - Selma Takmakli
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Istanbul, Turkiye
| | - Lokman Uzun
- Faculty of Science, Department of Chemistry, Hacettepe University, 06800 Ankara, Turkiye
| | - Gozde Ozaydin Ince
- Nanotechnology Research and Application Center (SUNUM), Sabanci University, 34956 Istanbul, Turkiye; Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Istanbul, Turkiye; Center of Excellence for Functional Surfaces and Interfaces (EFSUN), Sabanci University, 34956 Istanbul, Turkiye.
| |
Collapse
|
3
|
Er OF, Kivrak H, Alpaslan D, Dudu TE. One-Step Electrochemical Sensing of CA-125 Using Onion Oil-Based Novel Organohydrogels as the Matrices. ACS OMEGA 2024; 9:17919-17930. [PMID: 38680375 PMCID: PMC11044171 DOI: 10.1021/acsomega.3c09149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 03/06/2024] [Accepted: 03/20/2024] [Indexed: 05/01/2024]
Abstract
To reduce the high mortality rates caused by ovarian cancer, creating high-sensitivity, quick, basic, and inexpensive methods for following cancer antigen 125 (CA-125) levels in blood tests is of extraordinary significance. CA-125 is known as the exclusive glycoprotein employed in clinical examinations to monitor and diagnose ovarian cancer and detect its relapses as a tumor marker. Elevated concentrations of this antigen are linked to the occurrence of ovarian cancer. Herein, we designed organohydrogels (ONOHs) for identifying the level of CA-125 antigen at fast and high sensitivity with electrochemical strategies in a serum medium. The ONOH structures are synthesized with glycerol, agar, and glutaraldehyde and at distinct ratios of onion oil, and then, the ONOHs are characterized with Fourier transform infrared spectroscopy (FTIR) and scanning electron microscope (SEM). Electrochemical measurements are performed by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) in the absence and presence of CA-125 on the designed ONOHs. For the prepared ONOH-3 electrode, two distinct linear ranges are determined as 0.41-8.3 and 8.3-249.0 U/mL. The limit of quantitation and limit of detection values are calculated as 2.415 and 0.805 μU/mL, respectively, (S/N = 3). These results prove that the developed electrode material has high sensitivity, stability, and selectivity for the detection of the CA-125 antigen. In addition, this study can be reasonable for the practical detection of CA125 in serum, permitting early cancer diagnostics and convenient treatment.
Collapse
Affiliation(s)
- Omer Faruk Er
- Rare
Earth Elements Research Institute, Turkish Energy Nuclear and Mineral
Research Agency, Ankara 06980, Turkey
- Department
of Chemical Engineering, Faculty of Engineering, Van Yuzuncu Yil University, Van 65000, Turkey
| | - Hilal Kivrak
- Department
of Chemical Engineering, Faculty of Engineering and Architectural
Sciences, Eskisehir Osmangazi University, Eskisehir 26040, Turkey
- Translational
Medicine Research and Clinical Center, Eskisehir
Osmangazi University, Eskisehir 26040, Turkey
| | - Duygu Alpaslan
- Department
of Chemical Engineering, Faculty of Engineering, Van Yuzuncu Yil University, Van 65000, Turkey
| | - Tuba Ersen Dudu
- Department
of Chemical Engineering, Faculty of Engineering, Van Yuzuncu Yil University, Van 65000, Turkey
| |
Collapse
|
4
|
Ren X, Wu F, Wu M, Gao H, Wu C, Mu W, Liu S, Que L, Zhang H, Miao M, Chang D, Pan H. Sandwich-type immunosensor based on aminated 3D-rGOF-NH 2 and CMK-3-Fc-MgAl-LDH multilayer nanocomposites for detection of CA125. Bioelectrochemistry 2024; 156:108613. [PMID: 37995504 DOI: 10.1016/j.bioelechem.2023.108613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 11/15/2023] [Accepted: 11/16/2023] [Indexed: 11/25/2023]
Abstract
Cancer antigen 125 (CA125)1 is the most important biological screening indicator used to monitor epithelial ovarian cancers, and it plays a vital role in distinguishing ovarian cancers from benign diseases. Biosensors show great potential in the analysis and detection of disease markers. In this study, we designed electrochemical sensors based on three-dimensional amino-functionalized reduced graphene oxide (3D-rGOF-NH2),2 MgAl layered double hydroxide nanocomposites containing ordered mesoporous carbon (CMK-3),3 and ferrocene carboxylic acids(Fc-COOH)4for the detection of CA125. 3D-rGOF-NH2 possesses good conductivity, a large surface area, and high porosity, enabling more immobilized nanoparticles to be deposited on its surface with excellent stability. CMK-3@Fc@MgAl-LDH nanocomposite was used as a carrier to enhance the immobilization of antibodies and the loading of Fc, conductors to enhance conductivity, and enhancers to gradually amplify the signal of Fc. The surface morphology, elemental composition, and surface groups of the materials were characterized using scanning electron microscopy (SEM),5 transmission electron microscopy (TEM),6 and X-ray diffraction (XRD)7 techniques. The response signal of the electrochemical sensor was measured by DPV. Under the optimal conditions, the electrochemical sensor obtained a linear detection range of 0.01 U/mL-100 U/mL with a detection limit of 0.00417 U/mL.
Collapse
Affiliation(s)
- Xinshui Ren
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Shanghai University of Medicine and Health Sciences, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Fangfang Wu
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Mengdie Wu
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Shanghai University of Medicine and Health Sciences, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Hongmin Gao
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Chunyan Wu
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Wendi Mu
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Simin Liu
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Longbin Que
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Hehua Zhang
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Meng Miao
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Dong Chang
- Department of Laboratory Medicine, Shanghai Pudong Hospital, Shanghai 201399, China.
| | - Hongzhi Pan
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; The Affiliated Zhoupu Hospital, Shanghai University of Medicine & Health Sciences, Shanghai 201318, China.
| |
Collapse
|
5
|
Yılmaz M, Bilgi M. A disposable impedimetric immunosensor for the analysis of CA125 in human serum samples. Biomed Microdevices 2024; 26:8. [PMID: 38180587 DOI: 10.1007/s10544-023-00691-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/06/2023] [Indexed: 01/06/2024]
Abstract
Cancer antigen 125 (CA125) is the most common biomarker used to diagnose and monitor ovarian cancer progression for the last four decades, and precise detection of its levels in blood serum is crucial. In this work, label-free impedimetric CA125 immunosensors were fabricated by using screen-printed carbon electrodes modified with poly toluidine blue (PTB) (in deep eutectic solvent)/gold nanoparticles (AuNP) for the sensitive, environmentally friendly, economical, and practical analysis of CA125. The materials of PTBDES and AuNP were characterized by Fourier Transform Infrared (FT-IR), Scanning Electron Microscope (FE-SEM), and X-ray Diffraction (XRD). The analysis of the CA125 was performed by electrochemical impedance spectroscopy and the developed immunosensor. The immunosensor's repeatability, reproducibility, reusability, selectivity, and storage stability were examined. The developed label-free immunosensor allowed the determination of CA125 in fast, good repeatability and a low limit of detection (1.20 pg mL-1) in the linear range of 5-100 pg mL-1. The stable surface of the fabricated immunosensor was successfully regenerated ten times. The application of immunosensors in commercial human blood serum was performed, and good recoveries were achieved. The disposable label-free impedimetric CA125 immunosensor developed for the rapid and practical detection of CA125 is a candidate for use in point-of-care tests in clinical applications of ovarian cancer.
Collapse
Affiliation(s)
- Merve Yılmaz
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Türkiye
| | - Melike Bilgi
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Türkiye.
| |
Collapse
|
6
|
Raut J, Sarkar O, Das T, Mandal SM, Chattopadhyay A, Sahoo P. Efficient delivery of methotrexate to MDA-MB-231 breast cancer cells by a pH-responsive ZnO nanocarrier. Sci Rep 2023; 13:21899. [PMID: 38081993 PMCID: PMC10713526 DOI: 10.1038/s41598-023-49464-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 12/08/2023] [Indexed: 12/18/2023] Open
Abstract
Methotrexate (MTX), an efficient chemotherapy medication is used in treating various malignancies. However, the breast cancer cell line MDA-MB-231 has developed resistance to it due to low levels of the MTX transport protein, and reduced folate carrier (RFC), making it less effective against these cancer cells. Here we designed a very simple, biocompatible, and non-toxic amine-capped ZnO quantum dots to overcome the MTX resistance on the MDA-MB-231 breast cancer cell line. The QD was characterized by HRTEM, DLS EDX, FT-IR, UV-Vis, and Fluorescence spectroscopy. MTX loading onto the QD was confirmed through fluorescence and UV-Vis spectroscopy. Additionally, extensive confocal microscopic investigations were carried out to determine whether the MTX was successfully released on the MDA-MB-231 cell line. It was discovered that QD is a better pH-responsive delivery system than the previous ones because it successfully delivers MTX to the MDA-MB-231 at a higher rate on an acidic pH than it does at a physiological pH. QD also has anticancer activity and can eradicate cancer cells on its own. These factors make the QD to be an effective pH-responsive delivery system that can improve the efficacy of the medication in therapeutic diagnosis.
Collapse
Affiliation(s)
- Jiko Raut
- Department of Chemistry, Visva-Bharati University, Santiniketan, 731235, India
| | - Olivia Sarkar
- Department of Zoology, Visva-Bharati University, Santiniketan, 731235, India
| | - Tanmoy Das
- Department of Zoology, Visva-Bharati University, Santiniketan, 731235, India
| | - Santi M Mandal
- Central Research Facility, Indian Institute of Technology Kharagpur, Kharagpur, 721302, India
| | | | - Prithidipa Sahoo
- Department of Chemistry, Visva-Bharati University, Santiniketan, 731235, India.
| |
Collapse
|
7
|
Wen R, Wu X, Tian J, Lu J. A colorimetric aptasensor for CA125 determination based on dual catalytic performance of CeO 2 nanozyme confined in macroporous silica foam. Mikrochim Acta 2023; 190:470. [PMID: 37971689 DOI: 10.1007/s00604-023-06046-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 10/14/2023] [Indexed: 11/19/2023]
Abstract
A portable colorimetric aptasensor was constructed based on the dual catalytic performance of CeO2 nanozyme to determine carbohydrate antigen 125 (CA125). Firstly, CeO2 nanozyme was synthesized by calcination and ultrasonically dispersed in a macroporous silica foam (MSF) to form CeO2@MSF. Then the aptamer of CA125 (apt) and complementary DNA (c-DNA) were successively assembled on the CeO2@MSF to construct a CeO2@MSF/apt/c-DNA colorimetric aptasensor, which exhibited excellent oxidase-mimic performance and phosphatase-mimic activity simultaneously. In the presence of CA125, the apt specifically binds to target CA125, and the single-strand c-DNA leaves the CeO2@MSF/apt surface, which is catalytically hydrolyzed by exonuclease I. The produced phosphate ions inhibit the phosphatase-mimic activity of CeO2 nanozyme. Thus, the absorbance at 652 nm of 3,3',5,5'-tetramethylbenzidine solution containing ascorbic acid-2-phosphate increases with the concentration of CA125. The response is linearly related to the logarithm of CA125 concentration from 1.0 to 10.0 U/mL under optimal experimental conditions. Based on this, the constructed colorimetric aptasensor has a high sensitivity, good selectivity, and high accuracy for CA125 determination in real human serum sample.
Collapse
Affiliation(s)
- Ruiting Wen
- School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou, 221116, China
| | - Xingyang Wu
- School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou, 221116, China
| | - Jiuying Tian
- School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou, 221116, China.
| | - Jusheng Lu
- School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou, 221116, China.
| |
Collapse
|
8
|
Andone BA, Handrea-Dragan IM, Botiz I, Boca S. State-of-the-art and future perspectives in infertility diagnosis: Conventional versus nanotechnology-based assays. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2023; 54:102709. [PMID: 37717928 DOI: 10.1016/j.nano.2023.102709] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 08/27/2023] [Accepted: 09/07/2023] [Indexed: 09/19/2023]
Abstract
According to the latest World Health Organization statistics, around 50 to 80 million people worldwide suffer from infertility, amongst which male factors are responsible for around 20 to 30 % of all infertility cases while 50 % were attributed to the female ones. As it is becoming a recurrent health problem worldwide, clinicians require more accurate methods for the improvement of both diagnosis and treatment schemes. By emphasizing the potential use of innovative methods for the rapid identification of the infertility causes, this review presents the news from this dynamic domain and highlights the benefits brought by emerging research fields. A systematic description of the standard techniques used in clinical protocols for diagnosing infertility in both genders is firstly provided, followed by the presentation of more accurate and comprehensive nanotechnology-related analysis methods such as nanoscopic-resolution imaging, biosensing approaches and assays that employ nanomaterials in their design. Consequently, the implementation of nanotechnology related tools in clinical practice, as recently demonstrated in the selection of spermatozoa, the detection of key proteins in the fertilization process or the testing of DNA integrity or the evaluation of oocyte quality, might confer excellent advantages both for improving the assessment of infertility, and for the success of the fertilization process.
Collapse
Affiliation(s)
- Bianca-Astrid Andone
- Interdisciplinary Research Institute in Bio-Nano-Sciences, Babes-Bolyai University, 42 T. Laurian Str., 400271 Cluj-Napoca, Romania; Faculty of Physics, Babes-Bolyai University, 1 M. Kogalniceanu Str., 400084 Cluj-Napoca, Romania
| | - Iuliana M Handrea-Dragan
- Interdisciplinary Research Institute in Bio-Nano-Sciences, Babes-Bolyai University, 42 T. Laurian Str., 400271 Cluj-Napoca, Romania; Faculty of Physics, Babes-Bolyai University, 1 M. Kogalniceanu Str., 400084 Cluj-Napoca, Romania
| | - Ioan Botiz
- Interdisciplinary Research Institute in Bio-Nano-Sciences, Babes-Bolyai University, 42 T. Laurian Str., 400271 Cluj-Napoca, Romania
| | - Sanda Boca
- Interdisciplinary Research Institute in Bio-Nano-Sciences, Babes-Bolyai University, 42 T. Laurian Str., 400271 Cluj-Napoca, Romania; National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Str., 400293 Cluj-Napoca, Romania.
| |
Collapse
|
9
|
Chen Y, Huang Y, Chen S, Gao L, Zhang S, Dai H, Zeng B. A pressure-colorimetric multimode system with photothermal activated multiple rolling signal amplification for ovarian cancer biomarker detection. Talanta 2023; 265:124876. [PMID: 37390673 DOI: 10.1016/j.talanta.2023.124876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 06/19/2023] [Accepted: 06/21/2023] [Indexed: 07/02/2023]
Abstract
Utilizing the photothermal effect to activate enzyme activity, realize signal conversion and amplification show promising prospects in biosensing. Herein, a pressure-colorimetric multi-mode bio-sensor was proposed through the multiple rolling signal amplification strategy of photothermal control. Under NIR light radiation, the Nb2C MXene labeled photothermal probe caused notable temperature elevation on a multi-functional signal conversion paper (MSCP), leading to decomposition of thermal responsive element and in-situ formation of Nb2C MXene/Ag-Sx hybrid. The generation of Nb2C MXene/Ag-Sx hybrid accompanied with valid color change from pale yellow to dark brown on MSCP. Moreover, the Ag-Sx as a signal amplification element enhanced the NIR light absorption to further improve the photothermal effect of Nb2C MXene/Ag-Sx thereby induce cyclic in situ production of Nb2C MXene/Ag-Sx hybrid with rolling enhanced photothermal effect. Subsequently, the continuously enhanced photothermal effect rolling activated catalase-like activity of Nb2C MXene/Ag-Sx, which accelerated the decomposition of H2O2 and promoted the pressure elevation. Therefore, the rolling-enhanced photothermal effect and rolling activated catalase-like activity of Nb2C MXene/Ag-Sx considerately amplified the pressure and color change. Making full use of multi-signal readout conversion and rolling signal amplification, accurate results can be obtained in a short time, whether in the laboratory or in the patient's homes.
Collapse
Affiliation(s)
- Yanjie Chen
- College of Chemistry and Materials, Fujian Normal University, Fuzhou, Fujian, 350108, China.
| | - Yitian Huang
- College of Chemistry and Materials, Fujian Normal University, Fuzhou, Fujian, 350108, China
| | - Sisi Chen
- College of Chemistry and Materials, Fujian Normal University, Fuzhou, Fujian, 350108, China
| | - Lihong Gao
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang, 32400, China.
| | - Shupei Zhang
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang, 32400, China
| | - Hong Dai
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang, 32400, China.
| | - Baoshan Zeng
- College of Chemistry and Materials, Fujian Normal University, Fuzhou, Fujian, 350108, China.
| |
Collapse
|
10
|
Li S, Zhang H, Zhu M, Kuang Z, Li X, Xu F, Miao S, Zhang Z, Lou X, Li H, Xia F. Electrochemical Biosensors for Whole Blood Analysis: Recent Progress, Challenges, and Future Perspectives. Chem Rev 2023. [PMID: 37262362 DOI: 10.1021/acs.chemrev.1c00759] [Citation(s) in RCA: 78] [Impact Index Per Article: 39.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Whole blood, as one of the most significant biological fluids, provides critical information for health management and disease monitoring. Over the past 10 years, advances in nanotechnology, microfluidics, and biomarker research have spurred the development of powerful miniaturized diagnostic systems for whole blood testing toward the goal of disease monitoring and treatment. Among the techniques employed for whole-blood diagnostics, electrochemical biosensors, as known to be rapid, sensitive, capable of miniaturization, reagentless and washing free, become a class of emerging technology to achieve the target detection specifically and directly in complex media, e.g., whole blood or even in the living body. Here we are aiming to provide a comprehensive review to summarize advances over the past decade in the development of electrochemical sensors for whole blood analysis. Further, we address the remaining challenges and opportunities to integrate electrochemical sensing platforms.
Collapse
Affiliation(s)
- Shaoguang Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hongyuan Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Man Zhu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zhujun Kuang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xun Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Siyuan Miao
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zishuo Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xiaoding Lou
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hui Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xia
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| |
Collapse
|
11
|
Khan S, Cho WC, Sepahvand A, Haji Hosseinali S, Hussain A, Nejadi Babadaei MM, Sharifi M, Falahati M, Jaragh-Alhadad LA, ten Hagen TLM, Li X. Electrochemical aptasensor based on the engineered core-shell MOF nanostructures for the detection of tumor antigens. J Nanobiotechnology 2023; 21:136. [PMID: 37101280 PMCID: PMC10131368 DOI: 10.1186/s12951-023-01884-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 04/06/2023] [Indexed: 04/28/2023] Open
Abstract
It is essential to develop ultrasensitive biosensors for cancer detection and treatment monitoring. In the development of sensing platforms, metal-organic frameworks (MOFs) have received considerable attention as potential porous crystalline nanostructures. Core-shell MOF nanoparticles (NPs) have shown different diversities, complexities, and biological functionalities, as well as significant electrochemical (EC) properties and potential bio-affinity to aptamers. As a result, the developed core-shell MOF-based aptasensors serve as highly sensitive platforms for sensing cancer biomarkers with an extremely low limit of detection (LOD). This paper aimed to provide an overview of different strategies for improving selectivity, sensitivity, and signal strength of MOF nanostructures. Then, aptamers and aptamers-modified core-shell MOFs were reviewed to address their functionalization and application in biosensing platforms. Additionally, the application of core-shell MOF-assisted EC aptasensors for detection of several tumor antigens such as prostate-specific antigen (PSA), carbohydrate antigen 15-3 (CA15-3), carcinoembryonic antigen (CEA), human epidermal growth factor receptor-2 (HER2), cancer antigen 125 (CA-125), cytokeratin 19 fragment (CYFRA21-1), and other tumor markers were discussed. In conclusion, the present article reviews the advancement of potential biosensing platforms toward the detection of specific cancer biomarkers through the development of core-shell MOFs-based EC aptasensors.
Collapse
Affiliation(s)
- Suliman Khan
- Medical Research Center, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, China
- Department of Medical Lab Technology, The University of Haripur, Haripur, Pakistan
| | - William C. Cho
- Department of Clinical Oncology, Queen Elizabeth Hospital, Kowloon, Hong Kong China
| | - Afrooz Sepahvand
- Department of Cellular and Molecular Biology, Faculty of Advanced Science and Technology, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| | - Sara Haji Hosseinali
- Department of Genetics, Faculty of Advanced Science and Technology, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| | - Arif Hussain
- School of Life Sciences, Manipal Academy of Higher Education, Dubai, United Arab Emirates
| | - Mohammad Mahdi Nejadi Babadaei
- Department of Molecular Genetics, Faculty of Biological Science, North Tehran Branch, Islamic Azad University, Tehran, Iran
| | - Majid Sharifi
- Student Research Committee, School of Medicine, Shahroud University of Medical Sciences, Shahroud, Iran
- Depatment of Tissue Engineering, School of Medicine, Shahroud University of Medical Sciences, Shahroud, Iran
| | - Mojtaba Falahati
- Precision Medicine in Oncology (PrMiO), Department of Pathology, Erasmus MC Cancer Institute, Erasmus MC, Rotterdam, The Netherlands
- Nanomedicine Innovation Center Erasmus (NICE), Erasmus MC, Rotterdam, The Netherlands
| | | | - Timo L. M. ten Hagen
- Precision Medicine in Oncology (PrMiO), Department of Pathology, Erasmus MC Cancer Institute, Erasmus MC, Rotterdam, The Netherlands
- Nanomedicine Innovation Center Erasmus (NICE), Erasmus MC, Rotterdam, The Netherlands
| | - Xin Li
- Department of Neurology, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| |
Collapse
|
12
|
Runprapan N, Wang FM, Ramar A, Yuan CC. Role of Defects of Carbon Nanomaterials in the Detection of Ovarian Cancer Cells in Label-Free Electrochemical Immunosensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:1131. [PMID: 36772172 PMCID: PMC9919683 DOI: 10.3390/s23031131] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/04/2023] [Accepted: 01/10/2023] [Indexed: 06/18/2023]
Abstract
Developing label-free immunosensors to detect ovarian cancer (OC) by cancer antigen (CA125) is essential to improving diagnosis and protecting women from life-threatening diseases. Four types of carbon nanomaterials, such as multi-wall carbon nanotubes (MWCNTs), vapor-grown carbon fiber (VGCFs), graphite KS4, and carbon black super P (SP), have been treated with acids to prepare a carbon nanomaterial/gold (Au) nanocomposite. The AuNPs@carbon nanocomposite was electrochemically deposited on a glassy carbon electrode (GCE) to serve as a substrate to fabricate a label-free immunosensor for the detection of CA125. Among the four AuNPs@carbon composite, the AuNPs@MWCNTs-based sensor exhibited a high sensitivity of 0.001 µg/mL for the biomarker CA125 through the square wave voltammetry (SWV) technique. The high conductivity and surface area of MWCNTs supported the immobilization of AuNPs. Moreover, the carboxylic (COO-) functional groups in MWCNT improved to a higher quantity after the acid treatment, which served as an excellent support for the fabrication of electrochemical biosensors. The present method aims to explore an environmentally friendly synthesis of a layer-by-layer (LBL) assembly of AuNPs@carbon nanomaterials electrochemical immunoassay to CA125 in a clinical diagnosis at a low cost and proved feasible for point-of-care diagnosis.
Collapse
Affiliation(s)
- Nattharika Runprapan
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei 106, Taiwan
| | - Fu-Ming Wang
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei 106, Taiwan
- R&D Center for Membrane Technology, Chung Yuan Christian University, Taoyuan 320, Taiwan
- Sustainable Energy Center, National Taiwan University of Science and Technology, Taipei 106, Taiwan
- Department of Chemical Engineering, Chung Yuan Christian University, Taoyuan 320, Taiwan
| | - Alagar Ramar
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei 106, Taiwan
| | - Chiou-Chung Yuan
- Department of Obstetrics and Gynecology, Cheng Hsin General Hospital, Taipei 112, Taiwan
| |
Collapse
|
13
|
Pourali A, Omidi Y. Diagnosis of acute myocardial infarction: highlighting cardiac troponins as vital biomarkers. BIOIMPACTS : BI 2023; 13:85-88. [PMID: 37193078 PMCID: PMC10182445 DOI: 10.34172/bi.2023.22023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Accepted: 11/30/2021] [Indexed: 05/18/2023]
Abstract
The molecular marker, cardiac troponin (cTn) is a complex protein that is attached to tropomyosin on the actin filament. It is an essential biomolecule in terms of the calcium-mediated regulation of the contractile apparatus in myofibrils, the release of which is an indication of the dysfunction of cardiomyocytes and hence the initiation of ischemic phenomena in the heart tissue. Fast and accurate analysis of cTn may help the diagnosis and management of acute myocardial infarction (AMI), for which electrochemical biosensors and microfluidics devices can be of great benefit. This editorial aims to highlight the importance of cTn as vital biomarkers in AMI diagnosis.
Collapse
Affiliation(s)
- Ali Pourali
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Yadollah Omidi
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL33328, USA
- Corresponding author: Yadollah Omidi,
| |
Collapse
|
14
|
Explore how immobilization strategies affected immunosensor performance by comparing four methods for antibody immobilization on electrode surfaces. Sci Rep 2022; 12:22444. [PMID: 36575248 PMCID: PMC9794789 DOI: 10.1038/s41598-022-26768-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Accepted: 12/20/2022] [Indexed: 12/29/2022] Open
Abstract
Among the common methods used for antibody immobilization on electrode surfaces, which is the best available option for immunosensor fabrication? To answer this question, we first used graphene-chitosan-Au/Pt nanoparticle (G-Chi-Au/PtNP) nanocomposites to modify a gold electrode (GE). Second, avian reovirus monoclonal antibody (ARV/MAb) was immobilized on the GE surface by using four common methods, which included glutaraldehyde (Glu), 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide/N-hydroxysuccinimide (EDC/NHS), direct incubation or cysteamine hydrochloride (CH). Third, the electrodes were incubated with bovine serum albumin, four different avian reovirus (ARV) immunosensors were obtained. Last, the four ARV immunosensors were used to detect ARV. The results showed that the ARV immunosensors immobilized via Glu, EDC/NHS, direct incubation or CH showed detection limits of 100.63 EID50 mL-1, 100.48 EID50 mL-1, 100.37 EID50 mL-1 and 100.46 EID50 mL-1 ARV (S/N = 3) and quantification limits of 101.15 EID50 mL-1, and 101.00 EID50 mL-1, 100.89 EID50 mL-1 and 100.98 EID50 mL-1 ARV (S/N = 10), respectively, while the linear range of the immunosensor immobilized via CH (0-105.82 EID50 mL-1 ARV) was 10 times broader than that of the immunosensor immobilized via direct incubation (0-104.82 EID50 mL-1 ARV) and 100 times broader than those of the immunosensors immobilized via Glu (0-103.82 EID50 mL-1 ARV) or EDC/NHS (0-103.82 EID50 mL-1 ARV). And the four immunosensors showed excellent selectivity, reproducibility and stability.
Collapse
|
15
|
Analytical detection methods for azo dyes: A focus on comparative limitations and prospects of bio-sensing and electrochemical nano-detection. J Food Compost Anal 2022. [DOI: 10.1016/j.jfca.2022.104778] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
16
|
pH-Regulated Strategy and Mechanism of Antibody Orientation on Magnetic Beads for Improving Capture Performance of Staphylococcus Species. Foods 2022; 11:foods11223599. [PMID: 36429188 PMCID: PMC9689862 DOI: 10.3390/foods11223599] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 11/04/2022] [Accepted: 11/09/2022] [Indexed: 11/16/2022] Open
Abstract
Immunomagnetic beads (IMBs) have been widely used to capture and isolate target pathogens from complex food samples. The orientation of the antibody immobilized on the surface of magnetic beads (MBs) is closely related to the effective recognition with an antigen. We put forward an available strategy to orient the antibody on the surface of MBs by changing the charged amino group ratio of the reactive amino groups at optimal pH value. Quantum dots labeling antigen assay, antigen-binding fragment (Fab) accessibility assay and lysine mimicking were used for the first time to skillfully illustrate the antibody orientation mechanism. This revealed that the positively charged ε-NH2 group of lysine on the Fc relative to the uncharged amino terminus on Fab was preferentially adsorbed on the surface of MBs with a negatively charged group at pH 8.0, resulting in antigen binding sites of antibody fully exposed. This study contributes to the understanding of the antibody orientation on the surface of MBs and the potential application of IMBs in the separation and detection of pathogenic bacteria in food samples.
Collapse
|
17
|
Zhang F, Fan L, Liu Z, Han Y, Guo Y. A label-free electrochemical aptasensor for the detection of cancer antigen 125 based on nickel hexacyanoferrate nanocubes/polydopamine functionalized graphene. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116424] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
18
|
Tade RS, Patil PO. Biofabricated functionalized graphene quantum dots (fGQDs): Unravelling its fluorescence sensing mechanism of human telomerase reverse transcriptase (hTERT) antigen and in vitro bioimaging application. Biomed Mater 2022; 17. [PMID: 35896107 DOI: 10.1088/1748-605x/ac84ba] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 07/27/2022] [Indexed: 11/11/2022]
Abstract
Lung cancer (LC) is a deadly malignancy that is posing a serious threat to human health. Therefore, early detection of LC biomarkers is the key to reducing LC-related fatalities. Herein, we present the first fluorescent-based selective detection of LC biomarker human telomerase reverse transcriptase (hTERT) using polyethyleneimine (PEI) functionalized graphene quantum dots (fGQDs). One-pot in situ synthesis of amine-functionalized GQDs was accomplished by hydrothermal carbonization of biowaste-derived cellulose and PEI. Synthesized fGQDs were characterized by various analytical techniques. Synthesized fGQDs not only exhibited enhanced fluorescence life-time but also excellent stability in the different solvents compared to bare GQDs. The surface activation of hTERT-Ab by carbodiimide chemistry (EDC-NHS) resulted in stacking interactions with fGQDs, involving adsorption-desorption as well as competitive mechanisms. The higher inherent affinity of hTERT-Ag (hTERT antigen) for hTERT-Ab (hTERT antibody) resulted in complex formation and recovery of fGQD fluorescence. As a result, this fluorescence sensing demonstrated a greater linear detection range (0.01 ng mL-1 to 100 µg mL-1) as well as a notable low detection limit (36.3 pg mL-1). Furthermore, the fabricated immunosensor (Ab@fGQDs) has excellent stability and performance in real samples, with an average recovery of 97.32%. The results of cytotoxicity and cellular bioimaging study in A549 cells show that fGQDs can be used for additional nanotherapeutics and biological applications.
Collapse
Affiliation(s)
- Rahul S Tade
- Pharmaceutics, HR Patel Institute of Pharmaceutical Education and Research, Shirsoli PB, Jalgaon, Shirpur, Maharashtra, 425405, INDIA
| | - Pravin O Patil
- Department of Pharmaceutical Chemistry, H R Patel Institute of Pharmaceutical Education and Research, Shirpur 425405, Shirpur, Shirpur, 425405, INDIA
| |
Collapse
|
19
|
Manasa G, Mascarenhas RJ, Shetti NP, Malode SJ, Aminabhavi TM. Biomarkers for Early Diagnosis of Ovarian Carcinoma. ACS Biomater Sci Eng 2022; 8:2726-2746. [PMID: 35762531 DOI: 10.1021/acsbiomaterials.2c00390] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The leading cause of gynecological cancer-related morbidity and mortality is ovarian cancer (OC), which is dubbed a silent killer. Currently, OC is a target of intense biomarker research, because it is often not discovered until the disease is advanced. The goal of OC research is to develop effective tests using biomarkers that can detect the disease at the earliest stages, which would eventually decrease the mortality, thereby preventing recurrence. Therefore, there is a pressing need to revisit the existing biomarkers to recognize the potential biomarkers that can lead to efficient predictors for the OC diagnosis. This Perspective covers an update on the currently available biomarkers used in the triaging of OC to gain certain insights into the potential role of these biomarkers and their estimation that are crucial to the understanding of neoplasm progression, diagnostics, and therapy.
Collapse
Affiliation(s)
- G Manasa
- Electrochemistry Research Group, St. Joseph's College, Lalbagh Road, Bangalore - 560027, Karnataka, India
| | - Ronald J Mascarenhas
- Electrochemistry Research Group, St. Joseph's College, Lalbagh Road, Bangalore - 560027, Karnataka, India
| | - Nagaraj P Shetti
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidhyanagar, Hubballi - 580031, Karnataka, India
| | - Shweta J Malode
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidhyanagar, Hubballi - 580031, Karnataka, India
| | - Tejraj M Aminabhavi
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidhyanagar, Hubballi - 580031, Karnataka, India
| |
Collapse
|
20
|
Chen Z, Li B, Liu J, Li H, Li C, Xuan X, Li M. A label-free electrochemical immunosensor based on a gold-vertical graphene/TiO 2 nanotube electrode for CA125 detection in oxidation/reduction dual channels. Mikrochim Acta 2022; 189:257. [PMID: 35701556 DOI: 10.1007/s00604-022-05332-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 05/09/2022] [Indexed: 02/07/2023]
Abstract
A label-free immunosensor was constructed in oxidation and reduction dual channel mode for the trace detection of cancer antigen 125 (CA125) in serum. The gold-vertical graphene/titanium dioxide (Au-VG/TiO2) electrode was used as the signal-amplification platform, and cytosine and dopamine were used as probes in the oxidation and reduction channels, respectively. VG nanosheets were synthesized on a TiO2 nanotube array via chemical vapor deposition (CVD), and Au nanoparticles were deeply embedded on the surface and in the root of the VG nanosheets via electrodeposition. The CA125 antibody was then directly immobilized onto the electrode surface, benefitting from its natural affinity for Au nanoparticles. In the oxidation and reduction channels the CA125 antibody-Au-VG/TiO2 immune electrode had the same response concentration range (0.01-1000 mU∙mL-1) for the determination of the CA125 antigen. However, the oxidation channel had a higher sensitivity (14.82 μA•(log(mU•mL-1))-1 at a working potential of ~ 1.25 V vs. SCE), lower detection limit (0.0001 mU∙mL-1), higher stability, and lower performance deviation than the reduction channel. This immunosensor was successfully used for CA125 detection in human serum. The recoveries of spiked serum samples ranged from 99.8 ± 0.5 to 100 ± 0.4%. The study on the difference in the sensing performance between oxidation and reduction channels provides a preliminary experimental reference for exploring dual-channel synchronous detection immunosensors and verifying the accuracy of the assay based on dual-channel data, which will promote the development of reliable electrochemical immunosensor technology.
Collapse
Affiliation(s)
- Zehua Chen
- Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, Tianjin Key Laboratory of Drug Targeting and Bioimaging, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin, 300384, People's Republic of China
| | - Bingbing Li
- Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, Tianjin Key Laboratory of Drug Targeting and Bioimaging, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin, 300384, People's Republic of China
| | - Jinbiao Liu
- Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, Tianjin Key Laboratory of Drug Targeting and Bioimaging, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin, 300384, People's Republic of China.
| | - Hongji Li
- Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, Tianjin Key Laboratory of Drug Targeting and Bioimaging, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin, 300384, People's Republic of China.
| | - Cuiping Li
- Tianjin Key Laboratory of Film Electronic and Communication Devices, Engineering Research Center of Optoelectronic Devices & Communication Technology (Ministry of Education), School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, 300384, People's Republic of China
| | - Xiuwei Xuan
- Tianjin Key Laboratory of Film Electronic and Communication Devices, Engineering Research Center of Optoelectronic Devices & Communication Technology (Ministry of Education), School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, 300384, People's Republic of China
| | - Mingji Li
- Tianjin Key Laboratory of Film Electronic and Communication Devices, Engineering Research Center of Optoelectronic Devices & Communication Technology (Ministry of Education), School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, 300384, People's Republic of China.
| |
Collapse
|
21
|
Ebrahimi G, Samadi Pakchin P, Shamloo A, Mota A, de la Guardia M, Omidian H, Omidi Y. Label-free electrochemical microfluidic biosensors: futuristic point-of-care analytical devices for monitoring diseases. Mikrochim Acta 2022; 189:252. [PMID: 35687204 DOI: 10.1007/s00604-022-05316-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 04/20/2022] [Indexed: 10/18/2022]
Abstract
The integration of microfluidics with electrochemical analysis has resulted in the development of single miniaturized detection systems, which allows the precise control of sample volume with multianalyte detection capability in a cost- and time-effective manner. Microfluidic electrochemical sensing devices (MESDs) can potentially serve as precise sensing and monitoring systems for the detection of molecular markers in various detrimental diseases. MESDs offer several advantages, including (i) automated sample preparation and detection, (ii) low sample and reagent requirement, (iii) detection of multianalyte in a single run, (iv) multiplex analysis in a single integrated device, and (v) portability with simplicity in application and disposability. Label-free MESDs can serve an affordable real-time detection with a simple analysis in a short processing time, providing point-of-care diagnosis/detection possibilities in precision medicine, and environmental analysis. In the current review, we elaborate on label-free microfluidic biosensors, provide comprehensive insights into electrochemical detection techniques, and discuss the principles of label-free microfluidic-based sensing approaches.
Collapse
Affiliation(s)
- Ghasem Ebrahimi
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran.,Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Parvin Samadi Pakchin
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Amir Shamloo
- School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Ali Mota
- Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | - Hossein Omidian
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA
| | - Yadollah Omidi
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA.
| |
Collapse
|
22
|
State of the Art in Smart Portable, Wearable, Ingestible and Implantable Devices for Health Status Monitoring and Disease Management. SENSORS 2022; 22:s22114228. [PMID: 35684847 PMCID: PMC9185336 DOI: 10.3390/s22114228] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 05/25/2022] [Accepted: 05/26/2022] [Indexed: 02/01/2023]
Abstract
Several illnesses that are chronic and acute are becoming more relevant as the world's aging population expands, and the medical sector is transforming rapidly, as a consequence of which the need for "point-of-care" (POC), identification/detection, and real time management of health issues that have been required for a long time are increasing. Biomarkers are biological markers that help to detect status of health or disease. Biosensors' applications are for screening for early detection, chronic disease treatment, health management, and well-being surveillance. Smart devices that allow continual monitoring of vital biomarkers for physiological health monitoring, medical diagnosis, and assessment are becoming increasingly widespread in a variety of applications, ranging from biomedical to healthcare systems of surveillance and monitoring. The term "smart" is used due to the ability of these devices to extract data with intelligence and in real time. Wearable, implantable, ingestible, and portable devices can all be considered smart devices; this is due to their ability of smart interpretation of data, through their smart sensors or biosensors and indicators. Wearable and portable devices have progressed more and more in the shape of various accessories, integrated clothes, and body attachments and inserts. Moreover, implantable and ingestible devices allow for the medical diagnosis and treatment of patients using tiny sensors and biomedical gadgets or devices have become available, thus increasing the quality and efficacy of medical treatments by a significant margin. This article summarizes the state of the art in portable, wearable, ingestible, and implantable devices for health status monitoring and disease management and their possible applications. It also identifies some new technologies that have the potential to contribute to the development of personalized care. Further, these devices are non-invasive in nature, providing information with accuracy and in given time, thus making these devices important for the future use of humanity.
Collapse
|
23
|
Er OF, Kivrak H, Ozok O, Çelik S, Kivrak A. A novel electrochemical sensor for monitoring ovarian cancer tumor protein CA 125 on benzothiophene derivative based electrodes. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.115854] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
24
|
Vandghanooni S, Sanaat Z, Farahzadi R, Eskandani M, Omidian H, Omidi Y. Recent progress in the development of aptasensors for cancer diagnosis: Focusing on aptamers against cancer biomarkers. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106640] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
25
|
Vandghanooni S, Sanaat Z, Barar J, Adibkia K, Eskandani M, Omidi Y. Recent advances in aptamer-based nanosystems and microfluidics devices for the detection of ovarian cancer biomarkers. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116343] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
26
|
Abou-Omar MN, Attia MS, Afify HG, Amin MA, Boukherroub R, Mohamed EH. Novel Optical Biosensor Based on a Nano-Gold Coated by Schiff Base Doped in Sol/Gel Matrix for Sensitive Screening of Oncomarker CA-125. ACS OMEGA 2021; 6:20812-20821. [PMID: 34423189 PMCID: PMC8374908 DOI: 10.1021/acsomega.1c01974] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 06/15/2021] [Indexed: 05/07/2023]
Abstract
The urge for sensitive, facile, minimally invasive, and fast detection method of CA-125, a significant and crucial biomarker in ovarian malignancy, is currently substantial. This paper describes the detailed construction and characterization of a newly designed optical nano-biosensor to detect CA-125 accurately and sensitively. The fabricated sensor consists of a nano-gold thin film doped into a matrix of sol-gel, exhibiting a centered fluorescence band at 423 nm when excited at 340 nm. The quantification of CA-125 relies on its quenching ability of this fluorescence signal. The sensor was challenged to evaluate its sensitivity and specificity in detecting CA-125 present in samples collected from ovarian cancer diagnosed patients and compared to samples from healthy women as a control. Our findings revealed that the developed biosensor had a sensitivity of 97.35% and a specificity of 94.29%. Additionally, a wide linearity range over 2.0-127.0 U mL-1 for CA-125 was achieved with a detection limit of 1.45 U mL-1. Furthermore, the sensor could successfully discriminate samples between healthy and diseased people, which demonstrates its suitability in CA-125 assessment.
Collapse
Affiliation(s)
- Mona N. Abou-Omar
- Department
of Chemistry, Faculty of Women for Arts, Science and Education, Ain Shams University, Cairo 13013, Egypt
| | - Mohamed S. Attia
- Chemistry
Department, Faculty of Science, Ain Shams
University, Cairo 11566, Egypt
| | - Hisham G. Afify
- Department
of Chemistry, Faculty of Women for Arts, Science and Education, Ain Shams University, Cairo 13013, Egypt
| | - Mohammed A. Amin
- Department
of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
| | - Rabah Boukherroub
- Univ.
Lille, CNRS, Centrale Lille, Univ. Polytechnique
Hauts-de-France, UMR 8520 − IEMN, F-59000 Lille, France
| | - Ekram H. Mohamed
- Pharmaceutical
Chemistry Department, Faculty of Pharmacy, The British University in Egypt, 11837 El Sherouk City, Cairo, Egypt
| |
Collapse
|
27
|
Aptamer-Sensitized Nanoribbon Biosensor for Ovarian Cancer Marker Detection in Plasma. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9080222] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The detection of CA 125 protein in buffer solution with a silicon-on-insulator (SOI)-based nanoribbon (NR) biosensor was experimentally demonstrated. In the biosensor, sensor chips, bearing an array of 12 nanoribbons (NRs) with n-type conductance, were employed. In the course of the analysis with the NR biosensor, the target protein was biospecifically captured onto the surface of the NRs, which was sensitized with covalently immobilized aptamers against CA 125. Atomic force microscopy (AFM) and mass spectrometry (MS) were employed in order to confirm the formation of the probe–target complexes on the NR surface. Via AFM and MS, the formation of aptamer–antigen complexes on the surface of SOI substrates with covalently immobilized aptamers against CA 125 was revealed, thus confirming the efficient immobilization of the aptamers onto the SOI surface. The biosensor signal, resulting from the biospecific interaction between CA 125 and the NR-immobilized aptamer probes, was shown to increase with an increase in the target protein concentration. The minimum detectable CA 125 concentration was as low as 1.5 × 10−17 M. Moreover, with the biosensor proposed herein, the detection of CA 125 in the plasma of ovarian cancer patients was demonstrated.
Collapse
|
28
|
Li S, Hu C, Chen C, Zhang J, Bai Y, Tan CS, Ni G, He F, Li W, Ming D. Molybdenum Disulfide Supported on Metal–Organic Frameworks as an Ultrasensitive Layer for the Electrochemical Detection of the Ovarian Cancer Biomarker CA125. ACS APPLIED BIO MATERIALS 2021; 4:5494-5502. [DOI: 10.1021/acsabm.1c00324] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Shuang Li
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
| | - Chang Hu
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
- Tianjin International Engineering Institute, Tianjin University, Tianjin 300072, China
| | - Chong Chen
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
- Department of Clinical Laboratory, Tianjin Medical University Cancer Institute and Hospital, Tianjin 300060, China
| | - Jiawei Zhang
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
| | - Yongchang Bai
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
| | - Cherie S. Tan
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
| | - Guangjian Ni
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Feng He
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Weifeng Li
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
- Tianjin International Engineering Institute, Tianjin University, Tianjin 300072, China
| | - Dong Ming
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| |
Collapse
|
29
|
Asbaghian-Namin H, Karami P, Naghshara H, Gholamin D, Johari-Ahar M. Electrochemiluminescent immunoassay for the determination of CA15-3 and CA72-4 using graphene oxide nanocomposite modified with CdSe quantum dots and Ru(bpy) 3 complex. Mikrochim Acta 2021; 188:238. [PMID: 34184115 DOI: 10.1007/s00604-021-04890-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 06/10/2021] [Indexed: 11/30/2022]
Abstract
A novel immunoassay is introduced based on co-reactant enhancing strategy for the electrochemiluminescent (ECL) determination of CA15-3 and CA72-4 tumor markers in real samples. For the preparation of the signaling probe, CA15-3 and CA72-4 antibodies first were labeled using Ru(bpy)32+-N-hydroxysuccinimide ester (Ru(bpy)32+-NHS) and conjugated with L-cysteine capped cadmium selenide (CdSe) quantum dots. Finally, it was cross-linked with chitosan-grafted graphene oxide (GO@CS) nanocomposite. The capture probe was constructed by deposition of multi-walled carbon nanotubes (MWCNT) at the surface of dual-working gold screen-printed electrodes (MWCNT-dwSPE) and covalent attachment of capture CA15-3 and CA72-4 antibodies to MWCNT-dwSPE. ECL signals were recorded by applying cyclic potential ranging from 0.3 to 1.1 V (vs. pseudo-reference Ag/AgCl) at the scan rate of 100 mV.s-1. This immunoassay was used for determination of CA15-3 and CA72-4 in real samples the detection limits of 9.2 μU.ml-1 and 89 μU.ml-1 within linear ranges of 10 μU.ml-1-500 U.ml-1 and 100 μU.ml-1-150 U.ml-1, respectively. This immunoassay also showed acceptable accuracy with recoveries in the range 96.5-108 % and high reproducibility with RSD of 3.1 and 4.9.
Collapse
Affiliation(s)
- Hosein Asbaghian-Namin
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran.,School of Pharmacy, Ardabil University of Medical Sciences, Ardabil, Iran
| | - Pari Karami
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran
| | - Hamid Naghshara
- School of Pharmacy, Ardabil University of Medical Sciences, Ardabil, Iran
| | | | - Mohammad Johari-Ahar
- Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran. .,School of Pharmacy, Ardabil University of Medical Sciences, Ardabil, Iran.
| |
Collapse
|
30
|
Ultra-sensitive facile CdS nanocrystals-based electrochemical biosensor to detect myocardial infarction marker troponin. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106107] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
31
|
Vahedifard F, Chakravarthy K. Nanomedicine for COVID-19: the role of nanotechnology in the treatment and diagnosis of COVID-19. EMERGENT MATERIALS 2021; 4:75-99. [PMID: 33615140 PMCID: PMC7881345 DOI: 10.1007/s42247-021-00168-8] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Accepted: 01/19/2021] [Indexed: 05/12/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused the recent outbreak of coronavirus 2019 (COVID-19). Although nearly two decades have passed since the emergence of pandemics such as SARS-CoV and Middle East respiratory syndrome coronavirus (MERS-CoV), no effective drug against the CoV family has yet been approved, so there is a need to find newer therapeutic targets. Currently, simultaneous research across the globe is being performed to discover efficient vaccines or drugs, including both conventional therapies used to treat previous similar diseases and emerging therapies like nanomedicine. Nanomedicine has already proven its value through its application drug delivery and nanosensors in other diseases. Nanomedicine and its components can play an important role in various stages of prevention, diagnosis, treatment, vaccination, and research related to COVID-19. Nano-based antimicrobial technology can be integrated into personal equipment for the greater safety of healthcare workers and people. Various nanomaterials such as quantum dots can be used as biosensors to diagnose COVID-19. Nanotechnology offers benefits from the use of nanosystems, such as liposomes, polymeric and lipid nanoparticles, metallic nanoparticles, and micelles, for drug encapsulation, and facilitates the improvement of pharmacological drug properties. Antiviral functions for nanoparticles can target the binding, entry, replication, and budding of COVID-19. The toxicity-related inorganic nanoparticles are one of the limiting factors of its use that should be further investigated and modified. In this review, we are going to discuss nanomedicine options for COVID-19 management, similar applications for related viral diseases, and their gap of knowledge.
Collapse
Affiliation(s)
- Farzan Vahedifard
- Altman Clinical and Translational Research Institute, University of California San Diego Health Center, San Diego, CA USA
| | - Krishnan Chakravarthy
- Division of Pain Medicine, Department of Anesthesiology, University of California San Diego Health Center, 9400 Campus Point Dr, La Jolla, San Diego, CA USA
| |
Collapse
|
32
|
Ultrasensitive electrochemical immunosensor based on the signal amplification strategy of the competitive reaction of Zn2+ and ATP ions to construct a “signal on” mode GOx-HRP enzyme cascade reaction. Mikrochim Acta 2021; 188:61. [DOI: 10.1007/s00604-021-04720-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 01/19/2021] [Indexed: 01/20/2023]
|
33
|
Biswas S, Lan Q, Xie Y, Sun X, Wang Y. Label-Free Electrochemical Immunosensor for Ultrasensitive Detection of Carbohydrate Antigen 125 Based on Antibody-Immobilized Biocompatible MOF-808/CNT. ACS APPLIED MATERIALS & INTERFACES 2021; 13:3295-3302. [PMID: 33400479 DOI: 10.1021/acsami.0c14946] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In this work, a nanocomposite of Zr-trimesic acid MOF (MOF-808) with carbon nanotube (CNT) was synthesized through an in situ formation of MOF-808 on the activated CNT. The synthesized materials were characterized by powder X-ray diffraction, transmission electron microscopy, X-ray photoluminescence spectroscopy, Brunauer-Emmett-Teller, Fourier transform infrared spectroscopy, and Raman spectroscopy. The protein compatible nature with high surface area and electrocatalytic ability of MOF-808 was utilized to construct an immunosensor for ultra low-level detection of the ovarian cancer biomarker, carbohydrate antigen 125 (CA 125). The mutual benefit of each constituent of the MOF-808/CNT composite was capable of producing highly enhanced electrochemical properties. A glassy carbon electrode modified with MOF-808/CNT was used as a platform to fabricate a label-free electrochemical immunosensor. The antibody binding sites of MOF-808/CNT were enriched by functionalization with streptavidin. The immunosensor exhibited two linear determination ranges of 0.001-0.1 and 0.1-30 ng·mL-1, and the calculated limit of detection was 0.5 pg·mL-1 (S/N 3). The immunosensor showed excellent reproducibility and selectivity. The patient serum sample analysis was cross-verified with the electrochemiluminescence method with a relative error of 105-110%.
Collapse
Affiliation(s)
- Sudip Biswas
- College of Chemistry & Chemical Engineering, Yangzhou University, Yangzhou 225002, P. R. China
| | - Qingchun Lan
- College of Chemistry & Chemical Engineering, Yangzhou University, Yangzhou 225002, P. R. China
| | - Yao Xie
- College of Chemistry & Chemical Engineering, Yangzhou University, Yangzhou 225002, P. R. China
| | - Xin Sun
- College of Chemistry & Chemical Engineering, Yangzhou University, Yangzhou 225002, P. R. China
| | - Yang Wang
- College of Chemistry & Chemical Engineering, Yangzhou University, Yangzhou 225002, P. R. China
| |
Collapse
|
34
|
Chakraborty D, Naik S, Kumar S, Chandrasekaran N, Mukherjee A. Exploring the interactions between protein coronated CdSe quantum dots and nanoplastics. NEW J CHEM 2021; 45:7951-7958. [DOI: 10.1039/d1nj00441g] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2023]
Abstract
QDs after protein coronation can undergo sequential interaction with other pollutants which may alter the physiochemical property of the QDs and influence the stability of the corona proteins.
Collapse
Affiliation(s)
| | - Sanjay Naik
- Centre for Bioseparation Technology
- Vellore Institute of Technology
- Vellore
- India
| | - Sanjit Kumar
- Centre for Bioseparation Technology
- Vellore Institute of Technology
- Vellore
- India
| | - N. Chandrasekaran
- Centre for Nanobiotechnology
- Vellore Institute of Technology
- Vellore
- India
| | - Amitava Mukherjee
- Centre for Nanobiotechnology
- Vellore Institute of Technology
- Vellore
- India
| |
Collapse
|
35
|
Malsagova KA, Pleshakova TO, Galiullin RA, Kozlov AF, Shumov ID, Popov VP, Tikhonenko FV, Glukhov AV, Ziborov VS, Petrov OF, Fortov VE, Archakov AI, Ivanov YD. Highly Sensitive Detection of CA 125 Protein with the Use of an n-Type Nanowire Biosensor. BIOSENSORS-BASEL 2020; 10:bios10120210. [PMID: 33353197 PMCID: PMC7766891 DOI: 10.3390/bios10120210] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 12/17/2020] [Accepted: 12/17/2020] [Indexed: 12/18/2022]
Abstract
The detection of CA 125 protein in a solution using a silicon-on-insulator (SOI)-nanowire biosensor with n-type chip has been experimentally demonstrated. The surface of nanowires was modified by covalent immobilization of antibodies against CA 125 in order to provide the biospecificity of the target protein detection. We have demonstrated that the biosensor signal, which results from the biospecific interaction between CA 125 and the covalently immobilized antibodies, increases with the increase in the protein concentration. At that, the minimum concentration, at which the target protein was detectable with the SOI-nanowire biosensor, amounted to 1.5 × 10−16 M.
Collapse
Affiliation(s)
- Kristina A. Malsagova
- Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia; (T.O.P.); (R.A.G.); (A.F.K.); (I.D.S.); (V.S.Z.); (A.I.A.); (Y.D.I.)
- Correspondence: ; Tel.: +7-499-246-3761
| | - Tatyana O. Pleshakova
- Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia; (T.O.P.); (R.A.G.); (A.F.K.); (I.D.S.); (V.S.Z.); (A.I.A.); (Y.D.I.)
| | - Rafael A. Galiullin
- Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia; (T.O.P.); (R.A.G.); (A.F.K.); (I.D.S.); (V.S.Z.); (A.I.A.); (Y.D.I.)
| | - Andrey F. Kozlov
- Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia; (T.O.P.); (R.A.G.); (A.F.K.); (I.D.S.); (V.S.Z.); (A.I.A.); (Y.D.I.)
| | - Ivan D. Shumov
- Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia; (T.O.P.); (R.A.G.); (A.F.K.); (I.D.S.); (V.S.Z.); (A.I.A.); (Y.D.I.)
| | - Vladimir P. Popov
- Rzhanov Institute of Semiconductor Physics, Siberian Branch of Russian Academy of Sciences, 630090 Novosibirsk, Russia; (V.P.P.); (F.V.T.)
| | - Fedor V. Tikhonenko
- Rzhanov Institute of Semiconductor Physics, Siberian Branch of Russian Academy of Sciences, 630090 Novosibirsk, Russia; (V.P.P.); (F.V.T.)
| | - Alexander V. Glukhov
- JSC Novosibirsk Plant of Semiconductor Devices with OKB, 630082 Novosibirsk, Russia;
| | - Vadim S. Ziborov
- Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia; (T.O.P.); (R.A.G.); (A.F.K.); (I.D.S.); (V.S.Z.); (A.I.A.); (Y.D.I.)
- Joint Institute for High Temperatures of Russian Academy of Sciences, 125412 Moscow, Russia; (O.F.P.); (V.E.F.)
| | - Oleg F. Petrov
- Joint Institute for High Temperatures of Russian Academy of Sciences, 125412 Moscow, Russia; (O.F.P.); (V.E.F.)
| | - Vladimir E. Fortov
- Joint Institute for High Temperatures of Russian Academy of Sciences, 125412 Moscow, Russia; (O.F.P.); (V.E.F.)
| | - Alexander I. Archakov
- Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia; (T.O.P.); (R.A.G.); (A.F.K.); (I.D.S.); (V.S.Z.); (A.I.A.); (Y.D.I.)
| | - Yuri D. Ivanov
- Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia; (T.O.P.); (R.A.G.); (A.F.K.); (I.D.S.); (V.S.Z.); (A.I.A.); (Y.D.I.)
| |
Collapse
|
36
|
Yang Q, Gao Y, Xu L, Hong W, She Y, Yang G. Enzyme-driven micro/nanomotors: Recent advances and biomedical applications. Int J Biol Macromol 2020; 167:457-469. [PMID: 33278445 DOI: 10.1016/j.ijbiomac.2020.11.215] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2020] [Revised: 11/17/2020] [Accepted: 11/30/2020] [Indexed: 10/22/2022]
Abstract
Micro/nanomotors (MNMs), both self-propelled actuators and external fields-promoted machines, have joined forces in the past decade to accomplish versatile tasks such as precise detection and targeted cargo delivery with adequate propulsion and desirable locomotion. Amongst, enzyme-driven MNMs have been able to differentiate themselves from others owing to their distinct characteristics, such as absence of chemical fuel, enhanced cellular uptake and the possibility to be easily conjugated with many therapeutics, including both small molecules and biologics, displaying superior efficacy, enhanced specificity and diminished side effects. In the present review, we aim to highlight and summarize recent advances in enzyme-driven MNMs, particularly to provide an in-depth discussion focusing on the enzyme linking approaches onto those MNMs and motion control strategies of such MNMs with advantages and limitations thereof. Conclusions and future perspectives are also provided in brief.
Collapse
Affiliation(s)
- Qingliang Yang
- Research Institute of Pharmaceutical Particle Technology, College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou 310014, China
| | - Ying Gao
- Research Institute of Pharmaceutical Particle Technology, College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou 310014, China
| | - Lei Xu
- Research Institute of Pharmaceutical Particle Technology, College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou 310014, China
| | - Weiyong Hong
- Research Institute of Pharmaceutical Particle Technology, College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou 310014, China; Taizhou Municipal Hospital of Zhejiang Province, Taizhou 318000, China
| | - Yuanbin She
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China
| | - Gensheng Yang
- Research Institute of Pharmaceutical Particle Technology, College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou 310014, China.
| |
Collapse
|
37
|
Sangili A, Kalyani T, Chen SM, Nanda A, Jana SK. Label-Free Electrochemical Immunosensor Based on One-Step Electrochemical Deposition of AuNP-RGO Nanocomposites for Detection of Endometriosis Marker CA 125. ACS APPLIED BIO MATERIALS 2020; 3:7620-7630. [DOI: 10.1021/acsabm.0c00821] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Arumugam Sangili
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC
- Department of Biotechnology, National Institute of Technology, Papum Pare 791112, Arunachal Pradesh, India
| | - Thangapandi Kalyani
- Department of Biotechnology, National Institute of Technology, Papum Pare 791112, Arunachal Pradesh, India
| | - Shen-Ming Chen
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC
| | - Amalesh Nanda
- Department of Biotechnology, National Institute of Technology, Papum Pare 791112, Arunachal Pradesh, India
| | - Saikat Kumar Jana
- Department of Biotechnology, National Institute of Technology, Papum Pare 791112, Arunachal Pradesh, India
| |
Collapse
|
38
|
Wang FM, Huang SH, Yuan CC, Yeh CT, Chen WL, Wang XC, Runprapan N, Tsai YJ, Chuang YL, Su CH. Detection of O-glycosylated CA125 by using an electrochemical immunosensor for ovarian cancer diagnosis. J APPL ELECTROCHEM 2020. [DOI: 10.1007/s10800-020-01477-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
39
|
Systematic and validated techniques for the detection of ovarian cancer emphasizing the electro-analytical approach. Process Biochem 2020. [DOI: 10.1016/j.procbio.2020.04.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
40
|
de Castro ACH, Alves LM, Siquieroli ACS, Madurro JM, Brito-Madurro AG. Label-free electrochemical immunosensor for detection of oncomarker CA125 in serum. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104746] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
41
|
Leva-Bueno J, Peyman SA, Millner PA. A review on impedimetric immunosensors for pathogen and biomarker detection. Med Microbiol Immunol 2020; 209:343-362. [PMID: 32246198 PMCID: PMC7248053 DOI: 10.1007/s00430-020-00668-0] [Citation(s) in RCA: 89] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Accepted: 03/16/2020] [Indexed: 12/14/2022]
Abstract
Since the discovery of antibiotics in the first quarter of the twentieth century, their use has been the principal approach to treat bacterial infection. Modernized medicine such as cancer therapy, organ transplantation or advanced major surgeries require effective antibiotics to manage bacterial infections. However, the irresponsible use of antibiotics along with the lack of development has led to the emergence of antimicrobial resistance which is considered a serious global threat due to the rise of multidrug-resistant bacteria (Wang et al. in Antibiotic resistance: a rundown of a global crisis, pp. 1645-1658, 2018). Currently employed diagnostics techniques are microscopy, colony counting, ELISA, PCR, RT-PCR, surface-enhanced Raman scattering and others. These techniques provide satisfactory selectivity and sensitivity (Joung et al. in Sens Actuators B Chem 161:824-831, 2012). Nevertheless, they demand specialized personnel and expensive and sophisticated machinery which can be labour-intensive and time-consuming, (Malvano et al. in Sensors (Switzerland) 18:1-11, 2018; Mantzila et al. in Anal Chem 80:1169-1175, 2008). To get around these problems, new technologies such as biosensing and lab-on-a-chip devices have emerged in the last two decades. Impedimetric immunosensors function by applying electrochemical impedance spectroscopy to a biosensor platform using antibodies or other affinity proteins such as Affimers (Tiede et al. in Elife 6(c):1-35, 2017) or other binding proteins (Weiss et al. in Electrochim Acta 50:4248-4256, 2005) as bioreceptors, which provide excellent sensitivity and selectivity. Pre-enrichment steps are not required and this allows miniaturization and low-cost. In this review different types of impedimetric immunosensors are reported according to the type of electrode and their base layer materials, either self-assembled monolayers or polymeric layers, composition and functionalization for different types of bacteria, viruses, fungi and disease biomarkers. Additionally, novel protein scaffolds, both antibody derived and non-antibody derived, used to specifically target the analyte are considered.
Collapse
Affiliation(s)
- J. Leva-Bueno
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, LS2 9JT England, UK
| | - Sally A. Peyman
- Molecular and Nanoscale Physics Group, Department of Physics and Astronomy, University of Leeds, Leeds, LS2 9JS England, UK
| | - P. A. Millner
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, LS2 9JT England, UK
| |
Collapse
|
42
|
Sha R, Badhulika S. Recent advancements in fabrication of nanomaterial based biosensors for diagnosis of ovarian cancer: a comprehensive review. Mikrochim Acta 2020; 187:181. [PMID: 32076837 DOI: 10.1007/s00604-020-4152-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Accepted: 02/02/2020] [Indexed: 12/30/2022]
Abstract
Ovarian cancer is commonly diagnosed via determination of biomarkers like CA125, Mucin 1, HE4, and prostasin that can be present in the blood. However, there is a substantial need for less expensive, simpler, and portable diagnostic tools, both for timely diagnosis and management of ovarian cancer. This review (with 101 refs.) discusses various kinds of nanomaterial-based biosensors for tumor markers. Following an introduction into the field, a first section covers different kinds of biomarkers for ovarian cancer including CA125 (MUC16), mucin 1 (MUC1), human epididymis protein 4 (HE4), and prostasin. This is followed by a short overview on conventional diagnostic approaches. A large section is then presented on biosensors for determination of ovarian cancer, with subsections on optical biosensors (fluorimetric, colorimetric, surface plasmon resonance, chemiluminescence, electrochemiluminescence), on electrochemical sensors, molecularly imprinted sensors, paper-based biosensors, microfluidic (lab-on-a-chip) assays, chemiresistive and field effect transistor-based sensors, and giant magnetoresistive sensors. Tables are presented that give an overview on the wealth of methods and materials. A concluding section summarizes the current status, addresses current challenges, and gives an outlook on potential future trends. Graphical abstract Schematic representation of the review covering the advancements in the fabrication of various nanomaterial based biosensors for diagnosis of ovarian cancer.
Collapse
Affiliation(s)
- Rinky Sha
- Department of Electrical Engineering, Indian Institute of Technology, Hyderabad, 502285, India
| | - Sushmee Badhulika
- Department of Electrical Engineering, Indian Institute of Technology, Hyderabad, 502285, India.
| |
Collapse
|
43
|
Samadi Pakchin P, Fathi M, Ghanbari H, Saber R, Omidi Y. A novel electrochemical immunosensor for ultrasensitive detection of CA125 in ovarian cancer. Biosens Bioelectron 2020; 153:112029. [PMID: 31989938 DOI: 10.1016/j.bios.2020.112029] [Citation(s) in RCA: 72] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 01/08/2020] [Accepted: 01/13/2020] [Indexed: 01/06/2023]
Abstract
In the current study, we report on the design and development of a novel electrochemical immunosensor for the detection of cancer antigen 125 (CA125) oncomarker. Polyamidoamine/gold nanoparticles (PAMAM/AuNPs) were used to increase the conductivity and enhance the number of antibodies (Abs) immobilized on the electrode surface. Three-dimensional reduced graphene oxide-multiwall carbon nanotubes (3DrGO-MWCNTs) were used to modify the glassy carbon electrode to improve the electrode conductivity and specific surface area. Ab and toluidine blue attached to O-succinyl-chitosan-magnetic nanoparticles (Suc-CS@MNPs) as a tracer. The poor solubility of chitosan (CS) was improved by succinic anhydride using a novel modification method. Under optimum condition, the developed immunosensor exhibited a wide linear range (0.0005-75 U/mL) and an excellent limit of detection around 6 μU/mL. The reliability of the engineered immunosensor in detecting CA125 was verified by standard addition recovery method, which was further compared to enzyme-linked immunosorbent assay (ELISA). The proposed immunosensor exhibited excellent stability, high selectivity and sensitivity, and good reproducibility. Based on the great performance of the engineered immunosensor, it is proposed as a robust and reliable diagnostic tool for the detection of CA125 in the clinic.
Collapse
Affiliation(s)
- Parvin Samadi Pakchin
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran; Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Marziyeh Fathi
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hossein Ghanbari
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Reza Saber
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran; Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iran.
| | - Yadollah Omidi
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran; Department of Pharmaceutics, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran.
| |
Collapse
|
44
|
Yu J, Horsley JR, Abell AD. Unravelling electron transfer in peptide-cation complexes: a model for mimicking redox centres in proteins. Phys Chem Chem Phys 2020; 22:8409-8417. [DOI: 10.1039/d0cp00635a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
We provide evidence that bound zinc promotes electron transfer in a peptide by changing the electronic properties of the peptide.
Collapse
Affiliation(s)
- Jingxian Yu
- ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP)
- Institute of Photonics and Advanced Sensing (IPAS)
- Department of Chemistry
- The University of Adelaide
- Adelaide
| | - John R. Horsley
- ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP)
- Institute of Photonics and Advanced Sensing (IPAS)
- Department of Chemistry
- The University of Adelaide
- Adelaide
| | - Andrew D. Abell
- ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP)
- Institute of Photonics and Advanced Sensing (IPAS)
- Department of Chemistry
- The University of Adelaide
- Adelaide
| |
Collapse
|
45
|
Yin S, Ma Z. Self-sacrificial label assisted electroactivity conversion of sensing interface for ultrasensitive electrochemical immunosensor. Biosens Bioelectron 2019; 140:111355. [DOI: 10.1016/j.bios.2019.111355] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 05/23/2019] [Accepted: 05/26/2019] [Indexed: 12/11/2022]
|
46
|
Vilian ATE, Kim W, Park B, Oh SY, Kim T, Huh YS, Hwangbo CK, Han YK. Efficient electron-mediated electrochemical biosensor of gold wire for the rapid detection of C-reactive protein: A predictive strategy for heart failure. Biosens Bioelectron 2019; 142:111549. [PMID: 31400725 DOI: 10.1016/j.bios.2019.111549] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2019] [Revised: 07/26/2019] [Accepted: 07/28/2019] [Indexed: 11/18/2022]
Abstract
C-reactive protein (CRP) is considered a promising biomarker for the rapid and high-throughput real-time monitoring of cardiovascular disease and inflammation in unprocessed clinical samples. Implementation of this monitoring would enable various transformative biomedical applications. We have fabricated a highly specific sensor chip to detect CRP with a detection limit of 2.25 fg/mL. The protein was immobilized on top of a gold (Au) wire/polycarbonate (PC) substrate using 1-ethyl-3-(3-dimethylamino-propyl) carbodiimide hydrochloride/N-hydroxy succinimide-activated 3-mercaptoproponic acid (MPA) as a self-assembled monolayer agent and bovine serum albumin (BSA) as a blocking agent. In contrast to the bare PC substrate, the CRP/BSA/anti-CRP/MPA/Au substrate exhibited a considerably high electrochemical signal toward CRP. The influence of the experimental parameters on CRP detection was assessed via various analysis methods, and these parameters were then optimized. The linear dynamic range of the CRP was 5-220 fg/mL for voltammetric and impedance analysis. Morever, the strategy exhibited high selectivity against various potential interfering species and was capable of directly probing trace amounts of the target CRP in human serum with excellent selectivity. The analytical assay based on the CRP/BSA/anti-CRP/MPA/Au substrate could be exploited as a potentially useful tool for detecting CRP in clinical samples.
Collapse
Affiliation(s)
- A T Ezhil Vilian
- Department of Energy and Materials Engineering, Dongguk University-Seoul, Seoul, 100-715, Republic of Korea
| | - Wonyoung Kim
- Department of Physics, Inha University, 100 Inha-ro, Michuhol-gu, Incheon, 22212, Republic of Korea
| | - Bumjun Park
- Department of Biological Engineering, Inha University, 100 Inha-ro, Michuhol-gu, Incheon, 22212, Republic of Korea
| | - Seo Yeong Oh
- Department of Biological Engineering, Inha University, 100 Inha-ro, Michuhol-gu, Incheon, 22212, Republic of Korea
| | - TaeYoung Kim
- Department of Physics, Inha University, 100 Inha-ro, Michuhol-gu, Incheon, 22212, Republic of Korea
| | - Yun Suk Huh
- Department of Biological Engineering, Inha University, 100 Inha-ro, Michuhol-gu, Incheon, 22212, Republic of Korea.
| | - Chang Kwon Hwangbo
- Department of Physics, Inha University, 100 Inha-ro, Michuhol-gu, Incheon, 22212, Republic of Korea.
| | - Young-Kyu Han
- Department of Energy and Materials Engineering, Dongguk University-Seoul, Seoul, 100-715, Republic of Korea.
| |
Collapse
|
47
|
Rebelo TSCR, Costa R, Brandão ATSC, Silva AF, Sales MGF, Pereira CM. Molecularly imprinted polymer SPE sensor for analysis of CA-125 on serum. Anal Chim Acta 2019; 1082:126-135. [PMID: 31472701 DOI: 10.1016/j.aca.2019.07.050] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 06/29/2019] [Accepted: 07/22/2019] [Indexed: 10/26/2022]
Abstract
Considering the high incidence level and mortality rate of ovarian cancer, particularly among the European female population, the carbohydrate antigen 125 (CA-125) was selected as the protein target for this study for the development of a MIP-based biosensor. This work presents the development of molecular imprinting polymers (MIPs) on gold electrode surface for CA-125 biomarker recognition. The preparation of the CA-125 imprinting was obtained by electropolymerization of pyrrole (Py) monomer in a gold electrode using cyclic voltammetry (CV) in order to obtain highly selective materials with great molecular recognition capability. The quantification of CA-125 biomarker was made through the comparison of two methods: electrochemical (square wave voltammetry -SWV) and optical transduction (surface plasmon resonance -SPR). SWV has been widely used in biological molecules analysis since it is a fast and sensitive technique. In turn, SPR is a non-destructive optical technique that provides high-quality analytical data of CA-125 biomarker interactions with MIP. Several analytical parameters, such as sensitivity, linear response interval, and detection limit were determined to proceed to the performance evaluation of the electrochemical and optical transduction used in the development of the CA-125 biosensor. The biosensor based in the electrochemical transduction was the one that presented the best analytical parameters, yielding a good selectivity and a detection limit (LOD) of 0.01 U/mL, providing a linear concentration range between 0.01 and 500 U/mL. This electrochemical biosensor was selected for the study and it was successfully applied in the CA-125 analysis in artificial serum samples with recovery rates ranging from 91 to 105% with an average relative error of 5.8%.
Collapse
Affiliation(s)
- Tânia S C R Rebelo
- Centro de Investigação Em Química da Universidade Do Porto, Departamento de Química e Bioquímica, Faculdade de Ciências da Universidade Do Porto, Porto, Portugal; BioMark/ISEP, Instituto Superior de Engenharia Do Porto, Porto, Portugal
| | - Renata Costa
- Centro de Investigação Em Química da Universidade Do Porto, Departamento de Química e Bioquímica, Faculdade de Ciências da Universidade Do Porto, Porto, Portugal
| | - Ana T S C Brandão
- Centro de Investigação Em Química da Universidade Do Porto, Departamento de Química e Bioquímica, Faculdade de Ciências da Universidade Do Porto, Porto, Portugal
| | - A Fernando Silva
- Centro de Investigação Em Química da Universidade Do Porto, Departamento de Química e Bioquímica, Faculdade de Ciências da Universidade Do Porto, Porto, Portugal
| | - M Goreti F Sales
- BioMark/ISEP, Instituto Superior de Engenharia Do Porto, Porto, Portugal
| | - Carlos M Pereira
- Centro de Investigação Em Química da Universidade Do Porto, Departamento de Química e Bioquímica, Faculdade de Ciências da Universidade Do Porto, Porto, Portugal.
| |
Collapse
|
48
|
Wang M, Hu M, Li Z, He L, Song Y, Jia Q, Zhang Z, Du M. Construction of Tb-MOF-on-Fe-MOF conjugate as a novel platform for ultrasensitive detection of carbohydrate antigen 125 and living cancer cells. Biosens Bioelectron 2019; 142:111536. [PMID: 31362204 DOI: 10.1016/j.bios.2019.111536] [Citation(s) in RCA: 105] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 07/10/2019] [Accepted: 07/24/2019] [Indexed: 12/28/2022]
Abstract
Combining different metal-organic frameworks (MOFs) into a conjugate material can integrate the properties of each MOF component and further lead to emergent properties from the synergistic heterostructured units. In this work, two kinds of bimetallic TbFe-MOFs have been designed by MOF-on-MOF strategy and utilized as a platform for anchoring carbohydrate antigen 125 (CA125) aptamer to detect CA125 and living michigan cancer foundation-7 (MCF-7) cells. Although the integrated MOF-on-MOF architectures show similar chemical and structural features to that of the top layer, the Fe-MOF-on-Tb-MOF and Tb-MOF-on-Fe-MOF have different surface nanostructures to their parent MOFs. The developed aptasensor based on Tb-MOF-on-Fe-MOF displays higher stability of the formed G-quadruplex between aptamer and CA125 than that based on Fe-MOF-on-Tb-MOF, owing to stronger immobilization behavior of the aptamer for the Tb-MOF-on-Fe-MOF composite. The developed aptasensor provides an extremely low detection limit of 58 μU·mL-1 towards CA125 within a wide linear range from 100 μU·mL-1 to 200 U·mL-1, which is significantly lower than those of all reported sensors. This aptasensor also has high selectivity, good stability, acceptable reproducibility, and excellent applicability in human serum. Moreover, the Tb-MOF-on-Fe-MOF nanoarchitecture demonstrates superior biocompatibility and good endocytosis. As a result, the developed aptasensor illustrates high sensitivity for detection of MCF-7 cells with an extremely low detection limit of 19 cell·mL-1. Therefore, the proposed aptasensor based on Tb-MOF-on-Fe-MOF exhibits great potentials for early diagnosis of tumors.
Collapse
Affiliation(s)
- Minghua Wang
- Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry, Zhengzhou, 450002, PR China
| | - Mengyao Hu
- Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry, Zhengzhou, 450002, PR China
| | - Zhenzhen Li
- Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry, Zhengzhou, 450002, PR China
| | - Linghao He
- Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry, Zhengzhou, 450002, PR China
| | - Yingpan Song
- Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry, Zhengzhou, 450002, PR China
| | - Qiaojuan Jia
- Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry, Zhengzhou, 450002, PR China
| | - Zhihong Zhang
- Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry, Zhengzhou, 450002, PR China.
| | - Miao Du
- Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry, Zhengzhou, 450002, PR China.
| |
Collapse
|
49
|
Bahavarnia F, Saadati A, Hassanpour S, Hasanzadeh M, Shadjou N, Hassanzadeh A. Paper based immunosensing of ovarian cancer tumor protein CA 125 using novel nano-ink: A new platform for efficient diagnosis of cancer and biomedical analysis using microfluidic paper-based analytical devices (μPAD). Int J Biol Macromol 2019; 138:744-754. [PMID: 31326512 DOI: 10.1016/j.ijbiomac.2019.07.109] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 07/04/2019] [Accepted: 07/17/2019] [Indexed: 01/28/2023]
Abstract
Ovarian cancer is the first and most important cause of malignancy death in women. Mucin 16 or MUC16 protein also known as carcinoma antigen 125 (CA 125) is the most commonly used glycoprotein for early stage diagnosis of ovarian cancer. In this work, a novel paper-based bio-device through hand writing of Ag/RGO (silver nanoparticles/reduced graphene oxide) nano-ink on the flexible paper substrate using pen-on-paper technology was developed. The prepared interface was used to the recognition of CA 125 protein in human biofluid. For this purpose, Ag/rGO nano-ink was synthesized by deposition of Ag nanoparticles onto graphene oxide sheets and the reduction of graphene oxide to rGO simultaneously. Conductivity and resistance of conductive lines were studied after drawing on photographic paper. Subsequently, to prepare a new and unique immuno-device, paper electrode modified by cysteamine caped gold nanoparticles (CysA/Au NPs) using electrochemical techniques. CysA is bonded by sulfur atoms with Au (CysA/Au NPs), and from the amine group with hydroxyl and carboxyl groups of Ag/RGO nano-ink deposited on the surface of paper-based electrodes (CysA/Au NPs/Ag-rGO). Then, anti-CA 125 antibody was immobilized on the electrode surface through Au NPs and CA 125 positively charged amine groups interaction. Atomic force microscopy, Transmission electron microscopy, Field emission scanning electron microscopy, and dynamic light scattering, were performed to identify the engineered immunosensor. Using chronoamperometry technique and under the optimized conditions, the low limit of quantitation (LLOQ) for the proposed immunoassay was recorded as 0.78 U/ml, which this evaluation was performed at highly linear range of 0.78-400 U/ml. The high sensitivity of the electrochemical immunosensor device is indicative of the ability of this immuno-device to detect early stages ovarian cancer.
Collapse
Affiliation(s)
- Farnas Bahavarnia
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Arezoo Saadati
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Soodabeh Hassanpour
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohammad Hasanzadeh
- Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz 51664, Iran.
| | - Nasrin Shadjou
- Nanotechnology Research Center, Urmia University, Urmia, Iran
| | - Ahmad Hassanzadeh
- Department of Processing, Helmholtz-Institute Freiberg for Resource Technology, Helmholtz-Zentrum Dresden-Rossendorf, Chemnitzer Str. 40, 09599 Freiberg, Germany
| |
Collapse
|
50
|
Fan Y, Shi S, Ma J, Guo Y. A paper-based electrochemical immunosensor with reduced graphene oxide/thionine/gold nanoparticles nanocomposites modification for the detection of cancer antigen 125. Biosens Bioelectron 2019; 135:1-7. [DOI: 10.1016/j.bios.2019.03.063] [Citation(s) in RCA: 77] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 03/28/2019] [Accepted: 03/31/2019] [Indexed: 12/20/2022]
|