1
|
Xia X, Duolihong B, Ma X, Liu R, Yue S. AuPt/NF prepared with the lattice induction of substrate was applied to construct the electrochemical immunosensor for PCT detection. Bioelectrochemistry 2024; 160:108758. [PMID: 38878459 DOI: 10.1016/j.bioelechem.2024.108758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 06/04/2024] [Accepted: 06/05/2024] [Indexed: 09/15/2024]
Abstract
For the electrodeposition, the conductivity and lattice structure of substrate is important to the morphology and lattice of the deposited material. In this study, gold-platinum (AuPt) nanopartical was deposited on nickel foam (NF) based on the lattice induced orientation of the Ni substrate, and the obtained AuPt/NF was applied to construct electrochemical impedimetric immunosensor for procalcitonin (PCT) detection. As a new immunosensor matrix, NF with higher electrical conductance, flexibility and specific surface area, which can improve the plasticity, sensitivity and universality of the immunoelectrode. Due to the lattice matching between Au and Ni, ultrathin AuPt nanolayer with good biocompatibility and large surface area can be modified on the NF surface, which can bind more biomolecules and amplifies the change of impedance signal. Based on the synergistic effect between AuPt and NF, PCT detection based on this electrochemical impedimetric immunosensor with a wide linear range (0.2 pg mL-1 to 20 ng mL-1) and low detection limit (0.11 pg mL-1). In addition, this impedimetric immunosensor exhibits high recovery in the PCT detection of serum samples. This work provides a new thought and method for the construction of electrochemical immunosensor.
Collapse
Affiliation(s)
- Xiaohong Xia
- Key Laboratory of Oil and Gas Fine Chemicals, Ministry of Education and Xinjiang Uyghur Autonomous Region, School of Chemical Engineering and Technology, Xinjiang University, Urumqi 830017, China.
| | - Bawurejiang Duolihong
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources College of Chemistry, Xinjiang University, Urumqi, Xinjiang 830017, China
| | - Xiangdong Ma
- Key Laboratory of Oil and Gas Fine Chemicals, Ministry of Education and Xinjiang Uyghur Autonomous Region, School of Chemical Engineering and Technology, Xinjiang University, Urumqi 830017, China
| | - Rui Liu
- Key Laboratory of Oil and Gas Fine Chemicals, Ministry of Education and Xinjiang Uyghur Autonomous Region, School of Chemical Engineering and Technology, Xinjiang University, Urumqi 830017, China
| | - Shan Yue
- Key Laboratory of Oil and Gas Fine Chemicals, Ministry of Education and Xinjiang Uyghur Autonomous Region, School of Chemical Engineering and Technology, Xinjiang University, Urumqi 830017, China
| |
Collapse
|
2
|
Cotchim S, Kongkaew S, Thavarungkul P, Kanatharana P, Limbut W. A dual-electrode label-free immunosensor based on in situ prepared Au-MoO 3-Chi/porous graphene nanoparticles for point-of-care detection of cholangiocarcinoma. Talanta 2024; 272:125755. [PMID: 38364561 DOI: 10.1016/j.talanta.2024.125755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 02/01/2024] [Accepted: 02/05/2024] [Indexed: 02/18/2024]
Abstract
A novel label-free electrochemical immunosensor was prepared for the detection of carbohydrate antigen 19-9 (CA19-9) and carcinoembryonic antigen (CEA) as biomarkers of cholangiocarcinoma (CCA). A nanocomposite of gold nanoparticles, molybdenum trioxide, and chitosan (Au-MoO3-Chi) was layer-by-layer assembled on the porous graphene (PG) modified a dual screen-printed electrode using a self-assembling technique, which increased surface area and conductivity and enhanced the adsorption of immobilized antibodies. The stepwise self-assembling procedure of the modified electrode was further characterized morphologically and functionally. The electroanalytical detection of biomarkers was based on the interaction between the antibody and antigen of each marker via linear sweep voltammetry using ferrocyanide/ferricyanide as an electrochemical redox indicator. Under optimized conditions, the fabricated immunosensor showed linear relationships between current change (ΔI) and antigen concentrations in two ranges: 0.0025-0.1 U mL-1 and 0.1-1.0 U mL-1 for CA19-9, and 0.001-0.01 ng mL-1 and 0.01-1.0 ng mL-1 for CEA. The limits of detection (LOD) were 1.0 mU mL-1 for CA19-9 and 0.5 pg mL-1 for CEA. Limits of quantitation (LOQ) were 3.3 mU mL-1 for CA19-9 and 1.6 pg mL-1 for CEA. The selectivity of the developed immunosensor was tested on mixtures of antigens and was then successfully applied to determine CA19-9 and CEA in human serum samples, producing satisfactory results consistent with the clinical method.
Collapse
Affiliation(s)
- Suparat Cotchim
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Supatinee Kongkaew
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Panote Thavarungkul
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Proespichaya Kanatharana
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Warakorn Limbut
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
3
|
Lin X, Shi H, Zheng F, Zeng J. Simple and sensitive sandwich-like voltammetric immunosensing of procalcitonin. ANAL SCI 2024; 40:541-547. [PMID: 38227088 DOI: 10.1007/s44211-023-00485-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 11/29/2023] [Indexed: 01/17/2024]
Abstract
Procalcitonin (PCT) is a reliable biomarker in the early diagnosis of septicemia, pyemia and stroke-associated pneumonia. In this work, through preparing β-cyclodextrin/graphene (CD/GN) nanohybrid as carrier and amplifier simultaneously to band antibodies and probe molecules, a simple and innovative sandwich-like voltammetric immunosensor was proposed for the sensitive and effective determination of PCT. Owing to the host-guest recognition property, the antibodies of PCT can enter into the CD cavities to generate a stable complex; meanwhile, aminopyrene (AP) were introduced as the signal probe and it was adsorbed on the surface of GN via aminopyrine π-πinteraction. Based on the signal change from AP as a response signal which exhibits linearity to the concentration of PCT, a highly sensitive sandwich-type voltammetric immunosensor was developed successfully after optimizing various key parameters. The results demonstrated that the developed sensor had a considerably low detection limit (0.003 pg mL-1) and wide linearity of 0.01 pg mL-1 to 20.0 ng mL-1. This work offered a very simple and sensitive sensing strategy for PCT and other biomarkers via altering the specific antibodies simply, showing great potential applications.
Collapse
Affiliation(s)
- Xinfeng Lin
- Department of Respiratory and Critical Care Medicine, Fuzhou First Hospital Affiliated With Fujian Medical University, Fuzhou, People's Republic of China.
| | - Honghui Shi
- Department of Respiratory and Critical Care Medicine, Fuzhou First Hospital Affiliated With Fujian Medical University, Fuzhou, People's Republic of China
| | - Fu Zheng
- Department of Respiratory and Critical Care Medicine, Fuzhou First Hospital Affiliated With Fujian Medical University, Fuzhou, People's Republic of China
| | - Jiajun Zeng
- Department of Respiratory and Critical Care Medicine, Fuzhou First Hospital Affiliated With Fujian Medical University, Fuzhou, People's Republic of China
| |
Collapse
|
4
|
Vásquez V, Orozco J. Detection of COVID-19-related biomarkers by electrochemical biosensors and potential for diagnosis, prognosis, and prediction of the course of the disease in the context of personalized medicine. Anal Bioanal Chem 2023; 415:1003-1031. [PMID: 35970970 PMCID: PMC9378265 DOI: 10.1007/s00216-022-04237-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/30/2022] [Accepted: 07/18/2022] [Indexed: 02/07/2023]
Abstract
As a more efficient and effective way to address disease diagnosis and intervention, cutting-edge technologies, devices, therapeutic approaches, and practices have emerged within the personalized medicine concept depending on the particular patient's biology and the molecular basis of the disease. Personalized medicine is expected to play a pivotal role in assessing disease risk or predicting response to treatment, understanding a person's health status, and, therefore, health care decision-making. This work discusses electrochemical biosensors for monitoring multiparametric biomarkers at different molecular levels and their potential to elucidate the health status of an individual in a personalized manner. In particular, and as an illustration, we discuss several aspects of the infection produced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) as a current health care concern worldwide. This includes SARS-CoV-2 structure, mechanism of infection, biomarkers, and electrochemical biosensors most commonly explored for diagnostics, prognostics, and potentially assessing the risk of complications in patients in the context of personalized medicine. Finally, some concluding remarks and perspectives hint at the use of electrochemical biosensors in the frame of other cutting-edge converging/emerging technologies toward the inauguration of a new paradigm of personalized medicine.
Collapse
Affiliation(s)
- Viviana Vásquez
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010, Colombia
| | - Jahir Orozco
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010, Colombia.
| |
Collapse
|
5
|
Kaya SI, Cetinkaya A, Ozcelikay G, Samanci SN, Ozkan SA. Approaches and Challenges for Biosensors for Acute and Chronic Heart Failure. BIOSENSORS 2023; 13:282. [PMID: 36832048 PMCID: PMC9954479 DOI: 10.3390/bios13020282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 02/09/2023] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
Heart failure (HF) is a cardiovascular disease defined by several symptoms that occur when the heart cannot supply the blood needed by the tissues. HF, which affects approximately 64 million people worldwide and whose incidence and prevalence are increasing, has an important place in terms of public health and healthcare costs. Therefore, developing and enhancing diagnostic and prognostic sensors is an urgent need. Using various biomarkers for this purpose is a significant breakthrough. It is possible to classify the biomarkers used in HF: associated with myocardial and vascular stretch (B-type natriuretic peptide (BNP), N-terminal proBNP and troponin), related to neurohormonal pathways (aldosterone and plasma renin activity), and associated with myocardial fibrosis and hypertrophy (soluble suppression of tumorigenicity 2 and galactin 3). There is an increasing demand for the design of fast, portable, and low-cost biosensing devices for the biomarkers related to HF. Biosensors play a significant role in early diagnosis as an alternative to time-consuming and expensive laboratory analysis. In this review, the most influential and novel biosensor applications for acute and chronic HF will be discussed in detail. These studies will be evaluated in terms of advantages, disadvantages, sensitivity, applicability, user-friendliness, etc.
Collapse
Affiliation(s)
- Sariye Irem Kaya
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara 06018, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara 06560, Turkey
- Department of Analytical Chemistry, Graduate School of Health Sciences, Ankara University, Ankara 06110, Turkey
| | - Goksu Ozcelikay
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara 06560, Turkey
| | - Seyda Nur Samanci
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara 06560, Turkey
- Department of Analytical Chemistry, Graduate School of Health Sciences, Ankara University, Ankara 06110, Turkey
| | - Sibel A. Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara 06560, Turkey
| |
Collapse
|
6
|
Sampaio I, Takeuti NNK, Gusson B, Machado TR, Zucolotto V. Capacitive immunosensor for COVID-19 diagnosis. MICROELECTRONIC ENGINEERING 2023; 267:111912. [PMID: 36406866 PMCID: PMC9643278 DOI: 10.1016/j.mee.2022.111912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 11/05/2022] [Indexed: 06/16/2023]
Abstract
COVID-19 has spread worldwide and early detection has been the key to controlling its propagation and preventing severe cases. However, diagnostic devices must be developed using different strategies to avoid a shortage of supplies needed for tests' fabrication caused by their large demand in pandemic situations. Furthermore, some tropical and subtropical countries are also facing epidemics of Dengue and Zika, viruses with similar symptoms in early stages and cross-reactivity in serological tests. Herein, we reported a qualitative immunosensor based on capacitive detection of spike proteins of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of COVID-19. The sensor device exhibited a good signal-to-noise ratio (SNR) at 1 kHz frequency, with an absolute value of capacitance variation significantly smaller for Dengue and Zika NS1 proteins (|ΔC| = 1.5 ± 1.0 nF and 1.8 ± 1.0 nF, respectively) than for the spike protein (|ΔC| = 7.0 ± 1.8 nF). Under the optimized conditions, the established biosensor is able to indicate that the sample contains target proteins when |ΔC| > 3.8 nF, as determined by the cut-off value (CO). This immunosensor was developed using interdigitated electrodes which require a measurement system with a simple electrical circuit that can be miniaturized to enable point-of-care detection, offering an alternative for COVID-19 diagnosis, especially in areas where there is also a co-incidence of Zika and Dengue.
Collapse
Affiliation(s)
- Isabella Sampaio
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| | - Nayla Naomi Kusimoto Takeuti
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| | - Beatriz Gusson
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| | - Thales Rafael Machado
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| | - Valtencir Zucolotto
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo CP 369, 13560-970 São Carlos, SP, Brazil
| |
Collapse
|
7
|
An Electrochemical Immunosensor for the Determination of Procalcitonin Using the Gold-Graphene Interdigitated Electrode. BIOSENSORS 2022; 12:bios12100771. [PMID: 36290909 PMCID: PMC9599768 DOI: 10.3390/bios12100771] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 09/16/2022] [Accepted: 09/17/2022] [Indexed: 01/09/2023]
Abstract
Procalcitonin (PCT) is considered a sepsis and infection biomarker. Herein, an interdigitated electrochemical immunosensor for the determination of PCT has been developed. The interdigitated electrode was made of the laser-engraved graphene electrode decorated with gold (LEGE/Aunano). The scanning electron microscopy indicated the LEGE/Aunano has been fabricated successfully. After that, the anti-PTC antibodies were immobilized on the surface of the electrode by using 3-mercaptopropionic acid. The electrochemical performance of the fabricated immunosensor was studied using electrochemical impedance spectroscopy (EIS). The EIS method was used for the determination of PCT in the concentration range of 2.5–800 pg/mL with a limit of detection of 0.36 pg/mL. The effect of several interfering agents such as the C reactive protein (CRP), immunoglobulin G (IgG), and human serum albumin (HSA) was also studied. The fabricated immunosensor had a good selectivity to the PCT. The stability of the immunosensor was also studied for 1 month. The relative standard deviation (RSD) was obtained to be 5.2%.
Collapse
|
8
|
Zhao G, Yan Q, Wang B, Wang Visualzation N, Duolihong B, Xia X. CoFe-(oxy)hydroxide as a novel electrocatalytic tag in immunosensing for ultra-sensitive detection of procalcitonin based on the oxygen evolution reaction. Bioelectrochemistry 2022; 147:108217. [DOI: 10.1016/j.bioelechem.2022.108217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/04/2022] [Accepted: 07/21/2022] [Indexed: 11/02/2022]
|
9
|
Huang J, Cheng W, Li Y. 3D carbonized wood-based integrated electrochemical immunosensor for ultrasensitive detection of procalcitonin antigen. Talanta 2022; 238:122991. [PMID: 34857324 DOI: 10.1016/j.talanta.2021.122991] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 10/18/2021] [Accepted: 10/20/2021] [Indexed: 11/28/2022]
Abstract
This work presents a novel 3D carbonized wood-based integrated electrochemical immunosensor for ultrasensitive detection of procalcitonin (PCT) antigen at picogram level, achieving a wide linear detection range for PCT concentrations range from 0.05 to 90 pg mL-1 with a low detection limit of 0.014 pg mL-1 (S/N = 3), outperforming the previous reports. 3D carbonized wood as a new immunosensor matrix is used for electrochemical PCT biosensing, improving the stability of electrode and overcoming the disadvantages of traditional glassy carbon electrode (GCE). It obtained an excellent detection result, due to it has abundant mutual crisscross microchannels that promote the reactants and electrons transfer, greatly amplify the current signal. This novel sandwich-type electrochemical immunosensor is composed of 3D carbonized wood, carboxylic multi-walled carbon nanotube (cMWCNT), Au@Co3O4 core-shell nanosphere and Au/single layer nitrogen-doped graphene (Au/SL-NG), when it is applied for PCT detection in real clinical samples, it exhibits high accuracy same as enzyme-linked immunosorbent assay (ELISA) method.
Collapse
Affiliation(s)
- Jianzhi Huang
- School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, Guangdong, 523808, People's Republic of China.
| | - Wenxue Cheng
- School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, Guangdong, 523808, People's Republic of China
| | - Yanliang Li
- School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, Guangdong, 523808, People's Republic of China.
| |
Collapse
|
10
|
Alba-Patiño A, Vaquer A, Barón E, Russell SM, Borges M, de la Rica R. Micro- and nanosensors for detecting blood pathogens and biomarkers at different points of sepsis care. Mikrochim Acta 2022; 189:74. [PMID: 35080669 PMCID: PMC8790942 DOI: 10.1007/s00604-022-05171-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 12/26/2021] [Indexed: 12/29/2022]
Abstract
Severe infections can cause a dysregulated response leading to organ dysfunction known as sepsis. Sepsis can be lethal if not identified and treated right away. This requires measuring biomarkers and pathogens rapidly at the different points where sepsis care is provided. Current commercial approaches for sepsis diagnosis are not fast, sensitive, and/or specific enough for meeting this medical challenge. In this article, we review recent advances in the development of diagnostic tools for sepsis management based on micro- and nanostructured materials. We start with a brief introduction to the most popular biomarkers for sepsis diagnosis (lactate, procalcitonin, cytokines, C-reactive protein, and other emerging protein and non-protein biomarkers including miRNAs and cell-based assays) and methods for detecting bacteremia. We then highlight the role of nano- and microstructured materials in developing biosensors for detecting them taking into consideration the particular needs of every point of sepsis care (e.g., ultrafast detection of multiple protein biomarkers for diagnosing in triage, emergency room, ward, and intensive care unit; quantitative detection to de-escalate treatment; ultrasensitive and culture-independent detection of blood pathogens for personalized antimicrobial therapies; robust, portable, and web-connected biomarker tests outside the hospital). We conclude with an overview of the most utilized nano- and microstructured materials used thus far for solving issues related to sepsis diagnosis and point to new challenges for future development.
Collapse
Affiliation(s)
- Alejandra Alba-Patiño
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain
- Department of Chemistry, University of the Balearic Islands, Palma, Spain
| | - Andreu Vaquer
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain
- Department of Chemistry, University of the Balearic Islands, Palma, Spain
| | - Enrique Barón
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain.
| | - Steven M Russell
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain
| | - Marcio Borges
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain
- Multidisciplinary Sepsis Unit, ICU, Son Llàtzer University Hospital, Palma, Spain
| | - Roberto de la Rica
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain.
| |
Collapse
|
11
|
Zhang N, Feng J, Zhao G, Duan X, Wang Y, Zhang D, Wei Q. Ultrasensitive Photochemical Immunosensor Based on Flowerlike SnO 2/BiOI/Ag 2S Composites for Detection of Procalcitonin. BIOSENSORS 2021; 11:421. [PMID: 34821637 PMCID: PMC8615900 DOI: 10.3390/bios11110421] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 10/25/2021] [Accepted: 10/25/2021] [Indexed: 05/17/2023]
Abstract
Based on the necessity and urgency of detecting infectious disease marker procalcitonin (PCT), a novel unlabeled photoelectrochemical (PEC) immunosensor was prepared for the rapid and sensitive detection of PCT. Firstly, SnO2 porous nanoflowers with good photocatalytic performance were prepared by combining hydrothermal synthesis and calcining. BiOI nanoflowers were synthesized by facile ultrasonic mixed reaction. Ag2S quantum dots were deposited on SnO2/BiOI composites by in situ growth method. The SnO2/BiOI/Ag2S composites with excellent photoelectric properties were employed as substrate material, which could provide significantly enhanced and stable signal because of the energy level matching of SnO2, BiOI and Ag2S and the good light absorption performance. Accordingly, a PEC immunosensor based on SnO2/BiOI/Ag2S was constructed by using the layered modification method to achieve high sensitivity analysis of PCT. The linear dynamic range of the detection method was 0.50 pg·mL-1~100 ng·mL-1, and the detection limit was 0.14 pg·mL-1. In addition, the designed PEC immunosensor exhibited satisfactory sensitivity, selectivity, stability and repeatability, which opened up a new avenue for the analyzation of PCT and further provided guidance for antibiotic therapy.
Collapse
Affiliation(s)
- Nuo Zhang
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, China; (N.Z.); (X.D.)
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China; (J.F.); (G.Z.); (Q.W.)
| | - Jinhui Feng
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China; (J.F.); (G.Z.); (Q.W.)
| | - Guanhui Zhao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China; (J.F.); (G.Z.); (Q.W.)
| | - Xiaoyi Duan
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, China; (N.Z.); (X.D.)
| | - Yaoguang Wang
- Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China
| | - Daopeng Zhang
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, China; (N.Z.); (X.D.)
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China; (J.F.); (G.Z.); (Q.W.)
| |
Collapse
|
12
|
Cen SY, Ge XY, Chen Y, Wang AJ, Feng JJ. Label-free electrochemical immunosensor for ultrasensitive determination of cardiac troponin I based on porous fluffy-like AuPtPd trimetallic alloyed nanodendrites. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106568] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
13
|
Electrochemical Immunosensors for Quantification of Procalcitonin: Progress and Prospects. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9070182] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Human procalcitonin (PCT) is a peptide precursor of the calcium-regulating hormone calcitonin. Traditionally, PCT has been used as a biomarker for severe bacterial infections and sepsis. It has also been recently identified as a potential marker for COVID-19. Normally, serum PCT is intracellularly cleaved to calcitonin, which lowers the levels of PCT (<0.01 ng/mL). In severe infectious diseases and sepsis, serum PCT levels increase above 100 ng/mL in response to pro-inflammatory stimulation. Development of sensors for specific quantification of PCT has resulted in considerable improvement in the sensitivity, linear range and rapid response. Among the various sensing strategies, electrochemical platforms have been extensively investigated owing to their cost-effectiveness, ease of fabrication and portability. Sandwich-type electrochemical immunoassays based on the specific antigen–antibody interactions with an electrochemical transducer and use of nanointerfaces has augmented the electrochemical response of the sensors towards PCT. Identification of a superior combination of electrode material and nanointerface, and translation of the sensing platform into flexible and disposable substrates are under active investigation towards development of a point-of-care device for PCT detection. This review provides an overview of the existing detection strategies and limitations of PCT electrochemical immunosensors, and the emerging directions to address these lacunae.
Collapse
|
14
|
Electrochromic Performance and Capacitor Performance of α-MoO3 Nanorods Fabricated by a One-Step Procedure. COATINGS 2021. [DOI: 10.3390/coatings11070783] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this paper, we propose for the first time the synthesis of α-MoO3 nanorods in a one-step procedure at mild temperatures. By changing the growth parameters, the microstructure and controllable morphology of the resulting products can be customized. The average diameter of the as-prepared nanorods is about 200 nm. The electrochromic and capacitance properties of the synthesized products were studied. The results show that the electrochromic properties of α-MoO3 nanorods at 550 nm have 67% high transmission contrast, good cycle stability and fast response time. The MoO3 nanorods also exhibit a stable supercapacitor performance with 98.5% capacitance retention after 10,000 cycles. Although current density varies sequentially, the nanostructure always exhibits a stable capacitor to maintain 100%. These results indicate the as-prepared MoO3 nanorods may be good candidates for applications in electrochromic devices and supercapacitors.
Collapse
|
15
|
Wang XY, Feng YG, Wang AJ, Mei LP, Luo X, Xue Y, Feng JJ. Facile construction of ratiometric electrochemical immunosensor using hierarchical PtCoIr nanowires and porous SiO 2@Ag nanoparticles for accurate detection of septicemia biomarker. Bioelectrochemistry 2021; 140:107802. [PMID: 33794412 DOI: 10.1016/j.bioelechem.2021.107802] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 03/09/2021] [Accepted: 03/12/2021] [Indexed: 12/19/2022]
Abstract
Procalcitonin (PCT) is a sensitive and specific biomarker for sepsis diagnosis. In this study, a novel ratio-typed electrochemical immunosensor was constructed for reliable and sensitive assay of PCT based on hierarchical PtCoIr nanowires/polyethylene polyamine-grafted-ferrocene (PtCoIr HNWs/PEPA-Fc) and porous SiO2@Ag nanoparticles-toluidine blue (porous SiO2@Ag NPs-TB). Importantly, the PtCoIr HNWs/PEPA-Fc was first modified on the sensing interface, which harvested stable and strong electrochemical signals for readout of Fc due to the enriched anchoring sites created by the PtCoIr HNWs. Meanwhile, porous SiO2@Ag NPs-TB behaved as the label to conjugate with secondary antibody (Ab2), which also provided another strong detection signals originated from TB confined in such porous structures. The resulting immunosensor displayed a measurable output of procalcitonin (PCT) in the dynamic scope of 0.001 ~ 100 ng mL-1 with a low limit of detection (LOD) of 0.46 pg mL-1 (S/N = 3). Moreover, we exploited this strategy for PCT assay in a diluted human serum sample with acceptable results, exhibiting promising applications in the clinical analysis.
Collapse
Affiliation(s)
- Xiao-Yu Wang
- Jinhua Central Hospital, Jinhua 321001, China; Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Yi-Ge Feng
- Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Ai-Jun Wang
- Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Li-Ping Mei
- Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Xiliang Luo
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Sciences, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, China
| | - Yadong Xue
- Jinhua Central Hospital, Jinhua 321001, China.
| | - Jiu-Ju Feng
- Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China.
| |
Collapse
|
16
|
Pant A, Mackraj I, Govender T. Advances in sepsis diagnosis and management: a paradigm shift towards nanotechnology. J Biomed Sci 2021; 28:6. [PMID: 33413364 PMCID: PMC7790597 DOI: 10.1186/s12929-020-00702-6] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Accepted: 12/23/2020] [Indexed: 12/11/2022] Open
Abstract
Sepsis, a dysregulated immune response due to life-threatening organ dysfunction, caused by drug-resistant pathogens, is a major global health threat contributing to high disease burden. Clinical outcomes in sepsis depend on timely diagnosis and appropriate early therapeutic intervention. There is a growing interest in the evaluation of nanotechnology-based solutions for sepsis management due to the inherent and unique properties of these nano-sized systems. This review presents recent advancements in nanotechnology-based solutions for sepsis diagnosis and management. Development of nanosensors based on electrochemical, immunological or magnetic principals provide highly sensitive, selective and rapid detection of sepsis biomarkers such as procalcitonin and C-reactive protein and are reviewed extensively. Nanoparticle-based drug delivery of antibiotics in sepsis models have shown promising results in combating drug resistance. Surface functionalization with antimicrobial peptides further enhances efficacy by targeting pathogens or specific microenvironments. Various strategies in nanoformulations have demonstrated the ability to deliver antibiotics and anti-inflammatory agents, simultaneously, have been reviewed. The critical role of nanoformulations of other adjuvant therapies including antioxidant, antitoxins and extracorporeal blood purification in sepsis management are also highlighted. Nanodiagnostics and nanotherapeutics in sepsis have enormous potential and provide new perspectives in sepsis management, supported by promising future biomedical applications included in the review.
Collapse
Affiliation(s)
- Amit Pant
- Discipline of Pharmaceutical Sciences, College of Health Sciences, University of KwaZulu-Natal, Private Bag X54001, Durban, South Africa
| | - Irene Mackraj
- School of Laboratory Medicine and Medical Sciences, College of Health Sciences, University of KwaZulu-Natal, Private Bag X54001, Durban, South Africa
| | - Thirumala Govender
- Discipline of Pharmaceutical Sciences, College of Health Sciences, University of KwaZulu-Natal, Private Bag X54001, Durban, South Africa.
| |
Collapse
|
17
|
Garg M, Sharma AL, Singh S. Advancement in biosensors for inflammatory biomarkers of SARS-CoV-2 during 2019-2020. Biosens Bioelectron 2021; 171:112703. [PMID: 33049563 PMCID: PMC7544635 DOI: 10.1016/j.bios.2020.112703] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 10/03/2020] [Accepted: 10/06/2020] [Indexed: 01/08/2023]
Abstract
COVID-19 pandemic has affected everyone throughout the world and has resulted in the loss of lives of many souls. Due to the restless efforts of the researchers working hard day and night, some success has been gained for the detection of virus. As on date, the traditional polymerized chain reactions (PCR), lateral flow devices (LFID) and enzyme linked immunosorbent assays (ELISA) are being adapted for the detection of this deadly virus. However, a more exciting avenue is the detection of certain biomarkers associated with this viral infection which can be done by simply re-purposing our existing infrastructure. SARS-CoV-2 viral infection triggers various inflammatory, biochemical and hematological biomarkers. Because of the infection route that the virus follows, it causes significant inflammatory response. As a result, various inflammatory markers have been reported to be closely associated with this infection such as C-reactive proteins, interleukin-6, procalcitonin and ferritin. Sensing of these biomarkers can simultaneously help in understanding the illness level of the affected patient. Also, by monitoring these biomarkers, we can predict the viral infections in those patients who have low SARS-CoV-2 RNA and hence are missed by traditional tests. This can give more targets to the researchers and scientists, working in the area of drug development and provide better prognosis. In this review, we propose to highlight the conventional as well as the non-conventional methods for the detection of these inflammatory biomarkers which can act as a single platform of knowledge for the researchers and scientists working for the treatment of COVID-19.
Collapse
Affiliation(s)
- Mayank Garg
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh, 160030, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India
| | - Amit L Sharma
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh, 160030, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
| | - Suman Singh
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh, 160030, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
| |
Collapse
|
18
|
Emerging evidence for serum procalcitonin estimation at point-of-care and advancement in quantitative sensing strategies over the past decade. SENSORS INTERNATIONAL 2021. [DOI: 10.1016/j.sintl.2021.100107] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
|
19
|
Correia AR, Sampaio I, Comparetti EJ, Vieira NCS, Zucolotto V. Optimized PAH/Folic acid layer-by-layer films as an electrochemical biosensor for the detection of folate receptors. Bioelectrochemistry 2020; 137:107685. [PMID: 33120295 DOI: 10.1016/j.bioelechem.2020.107685] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 09/29/2020] [Accepted: 10/06/2020] [Indexed: 12/11/2022]
Abstract
Folate receptor alpha (FR-α) is a glycoprotein overexpressed in tumor cell surfaces, especially in gynecologic cancers, and can be used as a biomarker for diagnostics. Currently, FRα is quantified by positron emission tomography (PET) or fluorescence imaging techniques. However, these methods are costly and time-consuming. We report on the development of an electrochemical biosensor for FRα detection based on the use of nanostructured layer-by-layer (LbL) films as modified electrodes. Multilayer films were deposited on indium tin oxide (ITO) electrodes by the alternately assembling of positively charged polyallylamine hydrochloride (PAH) and negatively charged folic acid (FA), used as the biorecognition element. UV-vis and FTIR spectroscopies revealed the successful PAH and FA adsorption on ITO. Devices performance was evaluated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The [PAH/FA] films presented a good reproducibility (RSD of 1.12%) and stability when stored in the Tris-HCl solution (RSD 6.7%). The biosensor electrochemical response exhibited a linear relationship with FRα concentration in the range from 10 to 40 nM. The limit of detection reached for CV and EIS measurements were 0.7 and 1.5 nM, respectively. As a proof-of-concept, we show that the devices can differenciate tumor cells from healthy cell, showing an excellent selectivity. The biosensor device based on [PAH/FA] films represents a promising strategy for a simple, rapid, and low-cost cancer diagnosis through FRα quantification on the surface of cancer cells.
Collapse
Affiliation(s)
- Abilene Rodrigues Correia
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo, CP 369, 13560-970 São Carlos, SP, Brazil
| | - Isabella Sampaio
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo, CP 369, 13560-970 São Carlos, SP, Brazil.
| | - Edson José Comparetti
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo, CP 369, 13560-970 São Carlos, SP, Brazil
| | - Nirton Cristi Silva Vieira
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo, CP 369, 13560-970 São Carlos, SP, Brazil; Institute of Science and Technology, Federal University of São Paulo, 12231-280 São José dos Campos, SP, Brazil
| | - Valtencir Zucolotto
- GNano - Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo, CP 369, 13560-970 São Carlos, SP, Brazil
| |
Collapse
|
20
|
Deng L, Lai G, Fu L, Lin CT, Yu A. Enzymatic deposition of gold nanoparticles at vertically aligned carbon nanotubes for electrochemical stripping analysis and ultrasensitive immunosensing of carcinoembryonic antigen. Analyst 2020; 145:3073-3080. [PMID: 32142088 DOI: 10.1039/c9an02633a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Herein we combine the sandwich immunoreaction at a vertically aligned single-walled carbon nanotube (SWCNT)-based immunosensor and the enzymatically catalytic deposition of gold nanoparticles (Au NPs) by a gold nanoprobe to develop a novel electrochemical immunosensing method. The vertically arranged nanostructure was prepared through the covalent linking of terminally carboxylated SWCNTs at an aryldiazonium-modified electrode. It not only provides an excellent platform for the high density immobilization of antibodies to obtain the immunosensor but also serves as useful molecular wires to accelerate electron transfer during the electrochemical immunosensing process. Meanwhile, the enzymatic reaction of the nanoprobe prepared by surface functionalization of the nanocarrier of Au NPs by high-content glucoamylases can catalyze the deposition of a large number of Au NPs at the immunosensor. The electrochemical stripping analysis of these nanoparticles enabled the convenient signal transduction of the method. Due to the sensitive gold stripping analysis at the vertically aligned SWCNTs and the multi-enzyme signal amplification of the nanoprobe, the electrochemical signal response was greatly enhanced. Thus, the method can be used for the ultrasensitive detection of the tumor biomarker of carcinoembryonic antigen in a wide linear range of 5 orders of magnitude with a low detection limit of 0.48 pg mL-1. Considering its obvious performance superiorities, this immunosensing method exhibits an extensive prospect for practical applications.
Collapse
Affiliation(s)
- Liling Deng
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, Department of Chemistry, Hubei Normal University, Huangshi 435002, China.
| | | | | | | | | |
Collapse
|