1
|
Valenzuela EF, Minho LAC, Menezes HC, Cardeal ZL. Determination of pesticide residue in marginal lagoons of natural parks in Brazil using an improved calibrate passive sampler. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168003. [PMID: 37914113 DOI: 10.1016/j.scitotenv.2023.168003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 10/08/2023] [Accepted: 10/19/2023] [Indexed: 11/03/2023]
Abstract
Passive sampling is a sensitive and efficient method for analyzing pesticides in water. This article describes a hollow fiber liquid-phase microextraction (HF-LPME) device that was improved using polypropylene membranes grafted with nanocellulose for the passive sampling of pesticides in water. A comprehensive gas chromatography time-of-flight mass spectrometry (GCxGC/Q-TOFMS) system was used to separate, identify, and quantify pesticides. The sampling rates of 38 moderately hydrophobic to hydrophobic agricultural pesticides (2.18 < log Kow < 6.89) from different chemical classes, including the main triazine, organochlorine and organophosphate compounds, were calculated. A calibration process was applied to evaluate the role of flow velocity and select potential candidates for a possible performance reference compound (PRC). Sampling rates varied between 0.17 mL d-1 and 23.15 mL d-1. The accumulation curves identified linear periods ranging from 3 to 18 days. The new passive sampler device was applied for 8 days in rivers and marginal lagoons of natural parks of the São Francisco basin in Minas Gerais, Brazil and identified 10 target pesticides. Furthermore, 10 non-targeted pesticides were detected by the GCxGC/Q-TOFMS method.
Collapse
Affiliation(s)
- Eduard F Valenzuela
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, 31270901 Belo Horizonte, MG, Brazil
| | - Lucas A C Minho
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, 31270901 Belo Horizonte, MG, Brazil
| | - Helvécio C Menezes
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, 31270901 Belo Horizonte, MG, Brazil
| | - Zenilda L Cardeal
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, 31270901 Belo Horizonte, MG, Brazil.
| |
Collapse
|
2
|
Liang Y, Li H, Li S, Chen S. Organic diffusive gradients in thin films (o-DGT) for determining environmental behaviors of antibiotics: A review. JOURNAL OF HAZARDOUS MATERIALS 2023; 459:132279. [PMID: 37597396 DOI: 10.1016/j.jhazmat.2023.132279] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 07/30/2023] [Accepted: 08/11/2023] [Indexed: 08/21/2023]
Abstract
Antibiotics are recognized as effective medicine that has been extensively used in human and veterinary. Since the rate of releasing into the environment is stronger than the rate of elimination, antibiotics are regarded as persistent or "pseudo-persistent" organic compounds that result in the development of microbial antibiotic resistance. Therefore, assessment for their ecological risks to the environment are essential. Diffusive gradients in thin films for organic compounds (o-DGT) have been adapted to investigate the environmental behaviors of antibiotics. Currently, more than 20 compounds have been tested by o-DGT in waters and soil environments. In this review, we explained the theoretical reason that o-DGT is feasible to determine the labile fraction of antibiotics in different environmental media. The most used agarose diffusive gel, and various binding agents such as resin, porous carbon and nano-scale materials have been compared to optimize the sampling of antibiotics by o-DGT. Results of deploying o-DGT devices in waters and soils from previous studies were discussed to understand the bioavailability and dynamic transport of antibiotics. Also, we provided the feasibility analysis of using o-DGT in sediments for antibiotics measurements, which is required to be carried out in future studies. To have a deep view on the development of o-DGT, its technical limitations and viable improvements were summarized in this study for further applications on antibiotics research.
Collapse
Affiliation(s)
- Yixuan Liang
- Department of Environmental Science, Key Laboratory of Beijing on Regional Air Pollution Control, Beijing University of Technology, Beijing 100124, China
| | - Hanbing Li
- Department of Environmental Science, Key Laboratory of Beijing on Regional Air Pollution Control, Beijing University of Technology, Beijing 100124, China
| | - Sumei Li
- Department of Environmental Science, Key Laboratory of Beijing on Regional Air Pollution Control, Beijing University of Technology, Beijing 100124, China
| | - Sha Chen
- Department of Environmental Science, Key Laboratory of Beijing on Regional Air Pollution Control, Beijing University of Technology, Beijing 100124, China.
| |
Collapse
|
3
|
Pérez Ballesta P, Baù A, Field RA, Woolfenden E. Using the POD sampler for quantitative diffusive (passive) monitoring of volatile and very volatile organics in ambient air: Sampling rates and analytical performance. ENVIRONMENT INTERNATIONAL 2023; 179:108119. [PMID: 37597498 DOI: 10.1016/j.envint.2023.108119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 08/21/2023]
Abstract
POD diffusive samplers loaded with Carbopack X and Carbograph 5TD were exposed to certified calibration mixtures containing a total of 110 different ozone precursor and air toxic compounds. Constant sampling rates were identified for 39 ozone precursors and 33 air toxics. As 9 of these compounds were included in both mixtures, this meant a total of 63 different volatile and very volatile compounds were sampled using the POD with overall expanded uncertainties below 30 % for the sampling rate associated with the whole range of sampling times from 2 to 24 h. Carbograph 5TD exhibited superior performance for diffusive sampling of oxygenated and halogenated compounds in the air toxics mixture, while Carbopack X showed higher sampling efficiencies for aliphatic and aromatic hydrocarbons, as well as halogenated compounds derived from benzene and C2 carbon number hydrocarbons. A model has been developed and applied to estimate sampling rates, primarily for the more volatile and weakly adsorbed compounds, as a function of the collected amount of analyte and the exposure time. For an additional 9 ozone precursors on Carbopack X, and 11 air toxics on Carbograph 5TD, the expanded uncertainties of modelled sampling rates were reduced to below 30 % and have a significantly reduced uncertainty compared to those associated with an averaged sampling rate. The paper provides Freundlich's isotherm parameters for the estimated (modelled) sampling rates and defines a pragmatic approach to their application. It does so by identifying the best sampling time to use for the expected exposure concentrations and associated analyte masses. This allows for expansion of the sampling concentration range from hundreds ng m-3 to mg m-3, while avoiding saturation of the adsorbent. Finally, field measurement comparisons of POD samplers, pumped tube samplers and online gas chromatography (GC), for sampling periods of 3 and 7 days in a semi-rural background area, showed no significant differences between reported concentrations.
Collapse
Affiliation(s)
- P Pérez Ballesta
- European Commission, Joint Research Centre. Directorate C-Energy, Mobility and Climate. Clean Air and Climate Unit, I-21027, Ispra, VA, Italy.
| | - A Baù
- European Commission, Joint Research Centre. Directorate C-Energy, Mobility and Climate. Clean Air and Climate Unit, I-21027, Ispra, VA, Italy
| | - R A Field
- United Nations Environment Programme, 1 Rue Miollis, 75015 Paris, France
| | - E Woolfenden
- Markes International Ltd. 1000B Central Park, Western Avenue, Bridgend, CF31 3RT, UK
| |
Collapse
|
4
|
Lao W. Incorporating performance reference compounds in retractable/reusable solid phase microextraction fiber for passive sampling of hydrophobic organic contaminants in water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 872:162252. [PMID: 36801335 DOI: 10.1016/j.scitotenv.2023.162252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/08/2023] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
Solid phase microextraction (SPME) has been used to measure aqueous-phase hydrophobic organic chemicals (HOCs) in equilibrium passive sampling mode for over two decades. However, determination of the extent of equilibrium has not been well-established for the retractable/reusable SPME sampler (RR-SPME), especially in the field applications. The goal of this study was to establish a method regarding to sampler preparation and data processing to characterize the extent of equilibrium of HOCs on the RR-SPME (100-μm thickness of polydimethylsiloxane (PDMS) coating) by incorporating performance reference compounds (PRCs). A fast (4 h) PRC loading protocol was identified with using a ternary solvent mixture (i.e., acetone-methanol-water mixture (4:4:2, v/v)) to accommodate diverse carrier solvents of the PRCs. The isotropy of the RR-SPME was validated by a paired, co-exposure approach with 12 different PRCs. The aging factors measured with the co-exposure method approximately equal to one, indicating the isotropic behavior was not changed after storage at 15 °C and -20 °C for 28 days. As a method demonstration, the PRC-loaded RR-SPME samplers were deployed in the ocean off Santa Barbara, CA (USA) for 35 days. The PRCs approaching the extents of equilibrium ranged from 20 ± 15.5 % to 96.5 ± 1.5 % and showed a declining trend along with log KOW increase. A generic equation relationship was deduced based on a correlation relationship of desorption rate constant (k2) and log KOW to extrapolate non-equilibrium correction factor from the PRCs to the HOCs. The merit of the present study is manifested by its theory and implement to enable the RR-SPME passive sampler to be utilized in environmental monitoring.
Collapse
Affiliation(s)
- Wenjian Lao
- Southern California Coast Water Research Project Authority, Costa Mesa 92626, CA, USA.
| |
Collapse
|
5
|
Glanzmann V, Reymond N, Weyermann C, Estoppey N. An improved Chemcatcher-based method for the integrative passive sampling of 44 hydrophilic micropollutants in surface water - Part A: Calibration under four controlled hydrodynamic conditions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 871:162037. [PMID: 36740052 DOI: 10.1016/j.scitotenv.2023.162037] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 01/14/2023] [Accepted: 02/01/2023] [Indexed: 06/18/2023]
Abstract
When monitoring water quality with hydrophilic integrative passive sampling devices, it is crucial to use accurate sampling rates (RS) that account for exposure conditions such as hydrodynamics. This study aims at calibrating Chemcatcher-like passive samplers - styrene-divinylbenzene reverse phase sulfonate (SDB-RPS) extraction disk covered by a polyethersulfone (PES) membrane - at four water flow velocities (5 to 40 cm s-1) in a channel system. First, the four hydrodynamic conditions were characterized by measuring the mass transfer coefficients of the water boundary layer (kw) at the surface of the samplers using the alabaster dissolution method. Then, fifty-six samplers were deployed in the channels and exposed for 7 different intervals varying from 1 to 21 days. Thus, RS were determined at four different kw for 44 hydrophilic compounds, ranging from 0.015 to 0.115 L day-1. Relationships were established between kw and RS using models for mixed rate control by the membrane and the water boundary layer. The estimated parameters of those relationships are suitable for the determination of accurate RS when kw is measured in situ, for example by co-deploying silicone disks spiked with performance and reference compounds (PRC) as implemented in Part B.
Collapse
Affiliation(s)
- Vick Glanzmann
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland.
| | - Naomi Reymond
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| | - Céline Weyermann
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland.
| | - Nicolas Estoppey
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland; Norwegian Geotechnical Institute (NGI), P.O. Box. 3930 Ullevål Stadion, N-0806 Oslo, Norway
| |
Collapse
|
6
|
Okeme JO, Koelmel JP, Johnson E, Lin EZ, Gao D, Pollitt KJG. Wearable Passive Samplers for Assessing Environmental Exposure to Organic Chemicals: Current Approaches and Future Directions. Curr Environ Health Rep 2023:10.1007/s40572-023-00392-w. [PMID: 36821032 DOI: 10.1007/s40572-023-00392-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/11/2023] [Indexed: 02/24/2023]
Abstract
PURPOSE OF REVIEW We are continuously exposed to dynamic mixtures of airborne contaminants that vary by location. Understanding the compositional diversity of these complex mixtures and the levels to which we are each exposed requires comprehensive exposure assessment. This comprehensive analysis is often lacking in population-based studies due to logistic and analytical challenges associated with traditional measurement approaches involving active air sampling and chemical-by-chemical analysis. The objective of this review is to provide an overview of wearable passive samplers as alternative tools to active samplers in environmental health research. The review highlights the advances and challenges in using wearable passive samplers for assessing personal exposure to organic chemicals and further presents a framework to enable quantitative measurements of exposure and expanded use of this monitoring approach to the population scale. RECENT FINDINGS Overall, wearable passive samplers are promising tools for assessing personal exposure to environmental contaminants, evident by the increased adoption and use of silicone-based devices in recent years. When combined with high throughput chemical analysis, these exposure assessment tools present opportunities for advancing our ability to assess personal exposures to complex mixtures. Most designs of wearable passive samplers used for assessing exposure to semi-volatile organic chemicals are currently uncalibrated, thus, are mostly used for qualitative research. The challenge with using wearable samplers for quantitative exposure assessment mostly lies with the inherent complexity in calibrating these wearable devices. Questions remain regarding how they perform under various conditions and the uncertainty of exposure estimates. As popularity of these samplers grows, it is critical to understand the uptake kinetics of chemicals and the different environmental and meteorological conditions that can introduce variability. Wearable passive samplers enable evaluation of exposure to hundreds of chemicals. The review presents the state-of-the-art of technology for assessing personal exposure to environmental chemicals. As more studies calibrate wearable samplers, these tools present promise for quantitatively assessing exposure at both the individual and population levels.
Collapse
Affiliation(s)
- Joseph O Okeme
- Department of Environmental Health Sciences, Yale School of Public Health, 60 College Street, Room 523, New Haven, CT, 06510, USA
| | - Jeremy P Koelmel
- Department of Environmental Health Sciences, Yale School of Public Health, 60 College Street, Room 523, New Haven, CT, 06510, USA
| | - Emily Johnson
- Department of Environmental Health Sciences, Yale School of Public Health, 60 College Street, Room 523, New Haven, CT, 06510, USA
| | - Elizabeth Z Lin
- Department of Environmental Health Sciences, Yale School of Public Health, 60 College Street, Room 523, New Haven, CT, 06510, USA
| | - Dong Gao
- Department of Environmental Health Sciences, Yale School of Public Health, 60 College Street, Room 523, New Haven, CT, 06510, USA
| | - Krystal J Godri Pollitt
- Department of Environmental Health Sciences, Yale School of Public Health, 60 College Street, Room 523, New Haven, CT, 06510, USA.
| |
Collapse
|
7
|
Development of a New Method to Estimate the Water Purification Efficiency of Bulk-Supported Nanosorbents under Realistic Conditions. SEPARATIONS 2023. [DOI: 10.3390/separations10020140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
Abstract
The direct use of nanosorbents for water purification is limited due to their aggregation and the lack of techniques for their recovery from natural waters. To overcome these problems, the affixation of nanomaterials onto bulk, non-mobile supports has been proposed. However, a method to simulate the efficiency of these sorbents under realistic conditions is still not available. To address this need, this work describes a method for evaluating the sorption efficiency of nanosorbent materials incorporated on bulk supports under non-equilibrium conditions. The method combines the principles of passive sampling, an environmental monitoring technique that is based on passive diffusion of dissolved contaminants from water to a sorbent, with batch sorption experiments that measure sorption under equilibrium conditions, to determine the parameters associated with water purification. These parameters are the maximum sorption capacity of the sorbent and the sampling rate, which is the volume of contaminated water treated per unit of time. From these variables, the deployment time of the sorbent until reaching saturation is proposed as an alternative indicator of sorbent efficiency. As proof-of-principle, the removal of oxyanions from a Zr-metal-organic framework (MOR−1) immobilized on cotton textiles was investigated. The results show that the sorption capacity under passive diffusion uptake conditions, is approximately 20 mg/g for As(VI) and 36 mg/g Se(IV), which is 10 to 30 times lower compared to that determined in batch sorption studies, indicating that conventional equilibrium sorption overestimates the efficiency of the sorbents under realistic conditions. The application of the method to a worst-case scenario, involving the severe contamination of freshwaters with arsenate species, is also demonstrated.
Collapse
|
8
|
Kamali N, Abbas F, Lehane M, Griew M, Furey A. A Review of In Situ Methods-Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) for the Collection and Concentration of Marine Biotoxins and Pharmaceuticals in Environmental Waters. Molecules 2022; 27:7898. [PMID: 36431996 PMCID: PMC9698218 DOI: 10.3390/molecules27227898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 09/14/2022] [Accepted: 09/20/2022] [Indexed: 11/17/2022] Open
Abstract
Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) are in situ methods that have been applied to pre-concentrate a range of marine toxins, pesticides and pharmaceutical compounds that occur at low levels in marine and environmental waters. Recent research has identified the widespread distribution of biotoxins and pharmaceuticals in environmental waters (marine, brackish and freshwater) highlighting the need for the development of effective techniques to generate accurate quantitative water system profiles. In this manuscript, we reviewed in situ methods known as Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) for the collection and concentration of marine biotoxins, freshwater cyanotoxins and pharmaceuticals in environmental waters since the 1980s to present. Twelve different adsorption substrates in SPATT and 18 different sorbents in POCIS were reviewed for their ability to absorb a range of lipophilic and hydrophilic marine biotoxins, pharmaceuticals, pesticides, antibiotics and microcystins in marine water, freshwater and wastewater. This review suggests the gaps in reported studies, outlines future research possibilities and guides researchers who wish to work on water contaminates using Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) technologies.
Collapse
Affiliation(s)
- Naghmeh Kamali
- Mass Spectrometry Group, Department Physical Sciences, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
- HALPIN Centre for Research & Innovation, National Maritime College of Ireland (NMCI), Munster Technological University (MTU), P43 XV65 Ringaskiddy, Ireland
| | - Feras Abbas
- Mass Spectrometry Group, Department Physical Sciences, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
- CREATE (Centre for Research in Advanced Therapeutic Engineering) and BioExplore, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
| | - Mary Lehane
- Mass Spectrometry Group, Department Physical Sciences, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
- CREATE (Centre for Research in Advanced Therapeutic Engineering) and BioExplore, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
| | - Michael Griew
- HALPIN Centre for Research & Innovation, National Maritime College of Ireland (NMCI), Munster Technological University (MTU), P43 XV65 Ringaskiddy, Ireland
| | - Ambrose Furey
- Mass Spectrometry Group, Department Physical Sciences, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
- CREATE (Centre for Research in Advanced Therapeutic Engineering) and BioExplore, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
| |
Collapse
|
9
|
Feng B, Steinhauser G, Zhuo W, Li Z, Yao Y, Blenke T, Zhao C, Renz F, Chen B. Development and calibration of a modifiable passive sampler for monitoring atmospheric tritiated water vapor in different environments. ENVIRONMENT INTERNATIONAL 2022; 169:107505. [PMID: 36115249 DOI: 10.1016/j.envint.2022.107505] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 09/01/2022] [Accepted: 09/02/2022] [Indexed: 06/15/2023]
Abstract
Anthropogenic release of tritium from nuclear facilities is expected to increase significantly in the coming decades, which may cause radiation exposure to humans through the contamination of water and food chains. It is necessary and urgent to acquire detailed information about tritium in various environments for studying its behavior and assessing the potential radiation risk. In the atmosphere, although the passive sampling technique provides a low-cost and convenient way to characterize the dynamics of tritiated water vapor (HTO), a single, simple sampler configuration makes it difficult to collect sufficient and representative samples within the expected period from different environments. In this study, we systematically studied the impacts of sampler configurations on sampling performance and proposed a modifiable sampler design by scaling sampler geometry and adjusting absorbent to achieve different monitoring demands. The samplers were subsequently deployed at five sites in China and Germany for the field calibration and the measured results exhibited a good agreement between the adsorption process obtained in sites corrected with diffusion coefficient and the one calibrated in Shanghai. This suggests the feasibility of predicting sampling performance in the field based on known data. Finally, we developed a strategy for sampler modification and selection in different environments and demonstrated that using easily obtainable environmental data, our sampler can be optimized for any area without any time-consuming preliminary experiments. This work provides a scientific basis for establishing high-resolution atmospheric HTO database and expands the conventional empirical sampler design paradigm by demonstrating the feasibility of using quantitative indices for sampler performance customization.
Collapse
Affiliation(s)
- Bin Feng
- Institute of Radioecology and Radiation Protection, Leibniz Universität Hannover, 30419 Hannover, Germany; Institute of Radiation Medicine, Fudan University, Shanghai 200032, China
| | - Georg Steinhauser
- Institute of Radioecology and Radiation Protection, Leibniz Universität Hannover, 30419 Hannover, Germany; TU Wien, Institute of Applied Synthetic Chemistry & TRIGA Center Atominstitut, 1060 Vienna, Austria
| | - Weihai Zhuo
- Institute of Radiation Medicine, Fudan University, Shanghai 200032, China
| | - Zhiling Li
- Institute of Radiation Medicine, Fudan University, Shanghai 200032, China
| | - Yupeng Yao
- Institute of Radiation Medicine, Fudan University, Shanghai 200032, China
| | - Tobias Blenke
- Institute of Radioecology and Radiation Protection, Leibniz Universität Hannover, 30419 Hannover, Germany
| | - Chao Zhao
- Shanghai Institute of Measurement and Testing Technology, Shanghai 201203, China
| | - Franz Renz
- Institute of Inorganic Chemistry, Leibniz Universität Hannover, 30167 Hannover, Germany
| | - Bo Chen
- Institute of Radiation Medicine, Fudan University, Shanghai 200032, China.
| |
Collapse
|
10
|
Richardson AK, Irlam RC, Wright HR, Mills GA, Fones GR, Stürzenbaum SR, Cowan DA, Neep DJ, Barron LP. A miniaturized passive sampling-based workflow for monitoring chemicals of emerging concern in water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 839:156260. [PMID: 35644406 DOI: 10.1016/j.scitotenv.2022.156260] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 05/06/2022] [Accepted: 05/23/2022] [Indexed: 06/15/2023]
Abstract
The miniaturization of a full workflow for identification and monitoring of contaminants of emerging concern (CECs) is presented. Firstly, successful development of a low-cost small 3D-printed passive sampler device (3D-PSD), based on a two-piece methacrylate housing that held up to five separate 9 mm disk sorbents, is discussed. Secondly, a highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method reduced the need for large scale in-laboratory apparatus, solvent, reagents and reference material quantities for in-laboratory passive sampler device (PSD) calibration and extraction. Using hydrophilic-lipophilic balanced sorbents, sampling rates (Rs) were determined after a low 50 ng L-1 exposure over seven days for 39 pesticides, pharmaceuticals, drug metabolites and illicit drugs over the range 0.3 to 12.3 mL day-1. The high sensitivity LC-MS/MS method enabled rapid analysis of river water using only 10 μL of directly injected sample filtrate to measure occurrence of 164 CECs and sources along 19 sites on the River Wandle, (London, UK). The new 3D-PSD was then field-tested over seven days at the site with the highest number and concentration of CECs, which was down-river from a wastewater treatment plant. Almost double the number of CECs were identified in 3D-PSD extracts across sites in comparison to water samples (80 versus 42 CECs, respectively). Time-weighted average CEC concentrations ranged from 8.2 to 845 ng L-1, which were generally comparable to measured concentrations in grab samples. Lastly, high resolution mass spectrometry-based suspect screening of 3D-PSD extracts enabled 113 additional compounds to be tentatively identified via library matching, many of which are currently or are under consideration for the EU Watch List. This miniaturized workflow represents a new, cost-effective, and more practically efficient means to perform passive sampling chemical monitoring at a large scale. SYNOPSIS: Miniaturized, low cost, multi-disk passive samplers enabled more efficient multi-residue chemical contaminant characterization, potentially for large-scale monitoring programs.
Collapse
Affiliation(s)
- Alexandra K Richardson
- Dept. Analytical, Environmental & Forensic Sciences, Institute of Pharmaceutical Sciences, School of Cancer and Pharmaceutical Sciences, Faculty of Life Sciences & Medicine, King's College London, 150 Stamford Street, London SE1 9NH, United Kingdom; Environmental Research Group, MRC Centre for Environment & Health, School of Public Health, Faculty of Medicine, Imperial College London, 86 Wood Lane, London W12 0BZ, United Kingdom
| | - Rachel C Irlam
- Dept. Chemistry, School of Natural and Environmental Sciences, Newcastle University, Newcastle-upon-Tyne, NE1 7RU, United Kingdom
| | - Helena Rapp Wright
- Environmental Research Group, MRC Centre for Environment & Health, School of Public Health, Faculty of Medicine, Imperial College London, 86 Wood Lane, London W12 0BZ, United Kingdom
| | - Graham A Mills
- Faculty of Science and Health, University of Portsmouth, White Swan Road, Portsmouth PO1 2DT, United Kingdom
| | - Gary R Fones
- Faculty of Science and Health, University of Portsmouth, White Swan Road, Portsmouth PO1 2DT, United Kingdom
| | - Stephen R Stürzenbaum
- Dept. Analytical, Environmental & Forensic Sciences, Institute of Pharmaceutical Sciences, School of Cancer and Pharmaceutical Sciences, Faculty of Life Sciences & Medicine, King's College London, 150 Stamford Street, London SE1 9NH, United Kingdom
| | - David A Cowan
- Dept. Analytical, Environmental & Forensic Sciences, Institute of Pharmaceutical Sciences, School of Cancer and Pharmaceutical Sciences, Faculty of Life Sciences & Medicine, King's College London, 150 Stamford Street, London SE1 9NH, United Kingdom
| | - David J Neep
- Agilent Technologies UK Ltd, Essex Road, Church Stretton SY6 6AX, United Kingdom
| | - Leon P Barron
- Environmental Research Group, MRC Centre for Environment & Health, School of Public Health, Faculty of Medicine, Imperial College London, 86 Wood Lane, London W12 0BZ, United Kingdom.
| |
Collapse
|
11
|
Bivins A, Kaya D, Ahmed W, Brown J, Butler C, Greaves J, Leal R, Maas K, Rao G, Sherchan S, Sills D, Sinclair R, Wheeler RT, Mansfeldt C. Passive sampling to scale wastewater surveillance of infectious disease: Lessons learned from COVID-19. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 835:155347. [PMID: 35460780 PMCID: PMC9020839 DOI: 10.1016/j.scitotenv.2022.155347] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/05/2022] [Accepted: 04/13/2022] [Indexed: 05/09/2023]
Abstract
Much of what is known and theorized concerning passive sampling techniques has been developed considering chemical analytes. Yet, historically, biological analytes, such as Salmonella typhi, have been collected from wastewater via passive sampling with Moore swabs. In response to the COVID-19 pandemic, passive sampling is re-emerging as a promising technique to monitor SARS-CoV-2 RNA in wastewater. Method comparisons and disease surveillance using composite, grab, and passive sampling for SARS-CoV-2 RNA detection have found passive sampling with a variety of materials routinely produced qualitative results superior to grab samples and useful for sub-sewershed surveillance of COVID-19. Among individual studies, SARS-CoV-2 RNA concentrations derived from passive samplers demonstrated heterogeneous correlation with concentrations from paired composite samples ranging from weak (R2 = 0.27, 0.31) to moderate (R2 = 0.59) to strong (R2 = 0.76). Among passive sampler materials, electronegative membranes have shown great promise with linear uptake of SARS-CoV-2 RNA observed for exposure durations of 24 to 48 h and in several cases RNA positivity on par with composite samples. Continuing development of passive sampling methods for the surveillance of infectious diseases via diverse forms of fecal waste should focus on optimizing sampler materials for the efficient uptake and recovery of biological analytes, kit-free extraction, and resource-efficient testing methods capable of rapidly producing qualitative or quantitative data. With such refinements passive sampling could prove to be a fundamental tool for scaling wastewater surveillance of infectious disease, especially among the 1.8 billion persons living in low-resource settings served by non-traditional wastewater collection infrastructure.
Collapse
Affiliation(s)
- Aaron Bivins
- Department of Civil & Environmental Engineering, Louisiana State University, 3255 Patrick F. Taylor Hall, Baton Rouge, LA 70803, USA.
| | - Devrim Kaya
- School of Chemical, Biological, and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA
| | - Warish Ahmed
- CSIRO Land and Water, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia
| | - Joe Brown
- Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599-7431, USA
| | - Caitlyn Butler
- Department of Civil and Environmental Engineering, University of Massachusetts Amherst, 130 Natural Resources Rd., Amherst, MA 01003, USA
| | - Justin Greaves
- School of Environmental Sustainability, Loyola University Chicago, 6364 N. Sheridan Rd, Chicago, IL 60660, USA
| | - Raeann Leal
- Loma Linda University, School of Public Health, 24951 North Circle Drive, Loma Linda, CA 92354, USA
| | - Kendra Maas
- Microbial Analyses, Resources, and Services Facility, University of Connecticut, Storrs, CT 06269, USA
| | - Gouthami Rao
- Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599-7431, USA
| | - Samendra Sherchan
- Department of Environmental Health Sciences, Tulane University, New Orleans, LA 70112, USA; Center for Climate and Health, Morgan State University, Baltimore, MD 21251, USA
| | - Deborah Sills
- Bucknell University, Department of Civil and Environmental Engineering, Lewisburg, PA 17837, USA
| | - Ryan Sinclair
- Loma Linda University, School of Public Health, 24951 North Circle Drive, Loma Linda, CA 92354, USA
| | - Robert T Wheeler
- Department of Molecular & Biomedical Sciences, University of Maine, 5735 Hitchner Hall, Orono, ME 04469, USA; Graduate School of Biomedical Sciences and Engineering, University of Maine, 5735 Hitchner Hall, Orono, ME 04469, USA
| | - Cresten Mansfeldt
- University of Colorado Boulder, Department of Civil, Environmental, and Architectural Engineering, 1111 Engineering Drive, Boulder, CO 80309, USA; University of Colorado Boulder, Environmental Engineering Program, 4001 Discovery Dr, Boulder, CO 80303, USA
| |
Collapse
|
12
|
Gschwend P, MacFarlane J, Jensen D, Soo J, Saparbaiuly G, Borrelli R, Vago F, Oldani A, Zaninetta L, Verginelli I, Baciocchi R. In Situ Equilibrium Polyethylene Passive Sampling of Soil Gas VOC Concentrations: Modeling, Parameter Determinations, and Laboratory Testing. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:7810-7819. [PMID: 35537062 DOI: 10.1021/acs.est.1c07045] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The use of low-density polyethylene (PE) sheets as equilibrium passive soil gas samplers to quantify volatile organic compounds (VOCs) such as benzene, toluene, ethylbenzene, and xylenes, and chlorinated solvents (e.g., trichloroethene and tetrachloroethene) in unsaturated subsurface environments was evaluated via modeling and benchtop testing. Two methods were devised to quantify such VOCs in PE. Key chemical properties, including PE-water (KPEw) and PE-air (KPEa) partition coefficients and diffusivities in the PE (Dpe), were determined. These KPEw, KPEa, and Dpe values were consistent with extrapolations of data based on larger compounds. Using these parameter values, field equilibration times of less than 1 day were estimated for such VOCs when using 70-100 μm thick PE sheets. Further, benchtop batch tests carried out in jars filled with VOC-contaminated soils, after 1 or 2 days, showed concentrations in soil air deduced from PE that were consistent with concentrations deduced by analyzing either water or headspace gases recovered from the same tests. Thus, PE-based measurements may overcome inaccuracies from using total soil concentrations and equilibrium partitioning models that may overestimate vapor phase concentrations up to 2 orders of magnitude.
Collapse
Affiliation(s)
- Philip Gschwend
- Civil and Environmental Engineering, Massachusetts Institute of Technology (MIT), 15 Vassar Street, Cambridge, Massachusetts 02139, United States
| | - John MacFarlane
- Civil and Environmental Engineering, Massachusetts Institute of Technology (MIT), 15 Vassar Street, Cambridge, Massachusetts 02139, United States
| | - David Jensen
- Civil and Environmental Engineering, Massachusetts Institute of Technology (MIT), 15 Vassar Street, Cambridge, Massachusetts 02139, United States
| | - Jaren Soo
- Civil and Environmental Engineering, Massachusetts Institute of Technology (MIT), 15 Vassar Street, Cambridge, Massachusetts 02139, United States
| | - Galym Saparbaiuly
- Civil and Environmental Engineering, Massachusetts Institute of Technology (MIT), 15 Vassar Street, Cambridge, Massachusetts 02139, United States
| | - Raffaella Borrelli
- CHIFIS-Novara Laboratories (CENTR), Renewable, New Energies and Material Science Research Center (DE-R&D), Eni S.p.A, Via Fauser 4, Novara 28100, Italy
| | - Fabio Vago
- CHIFIS-Novara Laboratories (CENTR), Renewable, New Energies and Material Science Research Center (DE-R&D), Eni S.p.A, Via Fauser 4, Novara 28100, Italy
| | - Alessandro Oldani
- CHIFIS-Novara Laboratories (CENTR), Renewable, New Energies and Material Science Research Center (DE-R&D), Eni S.p.A, Via Fauser 4, Novara 28100, Italy
| | | | - Iason Verginelli
- Laboratory of Environmental Engineering, Department of Civil Engineering and Computer Science Engineering, University of Rome "Tor Vergata", Via del Politecnico 1, Rome 00133, Italy
| | - Renato Baciocchi
- Laboratory of Environmental Engineering, Department of Civil Engineering and Computer Science Engineering, University of Rome "Tor Vergata", Via del Politecnico 1, Rome 00133, Italy
| |
Collapse
|
13
|
Glanzmann V, Booij K, Reymond N, Weyermann C, Estoppey N. Determining the Mass Transfer Coefficient of the Water Boundary Layer at the Surface of Aquatic Integrative Passive Samplers. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:6391-6398. [PMID: 35420785 DOI: 10.1021/acs.est.1c08088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Passive sampling devices (PSDs) offer key benefits for monitoring chemical water quality, but the uptake process of PSDs for hydrophilic compounds still needs to be better understood. Determining mass transfer coefficients of the water boundary layer (kw) during calibration experiments and in situ monitoring would contribute toward achieving this; it allows for combining calibration data obtained at different temperature and hydrodynamic conditions and facilitate the translation of laboratory-derived calibration data to field exposure. This study compared two kw measurement methods applied to extraction disk housings (Chemcatcher), namely, alabaster dissolution and dissipation of performance reference compounds (PRCs) from silicone. Alabaster- and PRC-based kw were measured at four flow velocities (5-40 cm s-1) and two temperatures (11 and 20 °C) in a channel system. Data were compared using a relationship based on Sherwood, Reynolds, and Schmidt numbers. Good agreement was observed between data obtained at both temperatures, and for the two methods. Data were well explained by a model for mass transfer to a flat plate under laminar flow. It was slightly adapted to provide a semi-empirical model accounting for the effects of housing design on hydrodynamics. The use of PRC-spiked silicone to obtain in situ integrative kw for Chemcatcher-type PSDs is also discussed.
Collapse
Affiliation(s)
- Vick Glanzmann
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| | - Kees Booij
- PaSOC, Greate Pierwei 25, 8821 LV Kimswerd, The Netherlands
| | - Naomi Reymond
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| | - Céline Weyermann
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| | - Nicolas Estoppey
- School of Criminal Justice, University of Lausanne, Batochime building, 1015 Lausanne, Switzerland
| |
Collapse
|
14
|
Miller DD, Bajracharya A, Dickinson GN, Durbin TA, McGarry JKP, Moser EP, Nuñez LA, Pukkila EJ, Scott PS, Sutton PJ, Johnston NAC. Diffusive uptake rates for passive air sampling: Application to volatile organic compound exposure during FIREX-AQ campaign. CHEMOSPHERE 2022; 287:131808. [PMID: 34461330 PMCID: PMC8612956 DOI: 10.1016/j.chemosphere.2021.131808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 08/02/2021] [Accepted: 08/03/2021] [Indexed: 06/13/2023]
Abstract
Passive (diffusive) sampling using sorbents is an economical and versatile method of measuring pollutants in air, including volatile organic compounds (VOCs). Diffusive uptake rates (UTRs) are needed for each analyte to obtain average concentrations during a specific passive sampling time duration. Here, a simultaneous active/diffusive ambient air sampling technique on Tenax®TA was employed to measure 24-hours, 7, 14 and 28-days UTRs of up to 27 VOCs, including benzene, toluene, ethylbenzene, xylenes (BTEX), C6-C12 hydrocarbons, benzenes derivatives, tetrachloroethylene, pinenes and limonene. Samples were analyzed via thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) for desired analytes. Seven-day UTR values ranged from 0.17 to 0.59 mL/min and many compounds exhibited a linear relationship with UTR and time duration up to 14 or 28 days. This may be the most comprehensive UTR tabulation of VOCs on Tenax®TA for time periods of 24 hours -28 days available. These rates were applied to VOC data measured during the 2019 NASA/NOAA Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) campaign, with goals to determine the chemical composition of western US wildfire smoke and to assess human exposure to air toxics. Summer 2019 exposure levels of BTEX at five Northwestern cities were low and the cancer risk due to benzene was assessed during FIREX-AQ to be background or 1 × 10-6. The UTRs derived here can be useful in applications of diffusive sampling, including estimation of sub-chronic to chronic human exposure risk of air toxics and wildfire smoke.
Collapse
Affiliation(s)
- Dylan D Miller
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Aakriti Bajracharya
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Gabrielle N Dickinson
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Timbre A Durbin
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - John K P McGarry
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Elijah P Moser
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Laurel A Nuñez
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Elias J Pukkila
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Phillip S Scott
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Parke J Sutton
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Nancy A C Johnston
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA.
| |
Collapse
|
15
|
Godlewska K, Stepnowski P, Paszkiewicz M. Carbon nanotubes, activated carbon and Oasis HLB as sorbents of passive samplers for extraction of selected micropollutants — Comparison of sampling rates and extraction efficiency. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106975] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
16
|
Liu S, Chen S, Li X, Yue Y, Li J, Williams PN, Wang Z, Li C, Yang Y, Ying GG, Chen CE. Development and application of diffusive gradients in thin-films for in situ sampling of the bitterest chemical - denatonium benzoate in waters. JOURNAL OF HAZARDOUS MATERIALS 2021; 418:126393. [PMID: 34329009 DOI: 10.1016/j.jhazmat.2021.126393] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/08/2021] [Accepted: 06/09/2021] [Indexed: 06/13/2023]
Abstract
Denatonium benzoate (DB), a commonly used bitter agent in numerous products, has recently been recognized as a waterborne contaminant due to concern about its potential persistence, mobility and toxicity (PMT). However, its occurrence, levels and fate in global aquatic environments are largely unknown. In this study, a new sampling method, based on diffusive gradients in thin films (DGT) with mixed-mode cation exchange (MCX) as the binding agent, was developed for measuring DB in waters. MCX shows a rapid adsorption and high capacity for DB. DB is linearly accumulated by MCX-DGT. pH (6-8), ionic strength (0.01-0.5 M), or DOM (0-10 M) do not show any significant effect on the MCX-DGT performance, confirming its reliability. The DGT measurements in a wastewater treatment plant (WWTP) are comparable to those by paralleled grab sampling. The field results suggest DB is persistent in WWTPs and could be a potential domestic wastewater indicator. Therefore, MCX-DGT is a promising technique for understanding the environmental occurrence, levels and fate of DB. This is a first report of using DGT for DB monitoring and of DB occurrence in Chinese environments. Further exploration of DGT as a reliable passive monitoring tool for a wide range of PMT substances in different applications is warranted.
Collapse
Affiliation(s)
- Sisi Liu
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Shibao Chen
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Xiaohao Li
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Yubo Yue
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Jinling Li
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Paul N Williams
- Institute for Global Food Security, Queen's University Belfast, Biological Sciences, 19 Chlorine Gardens, Belfast BT9 5DL, UK
| | - Zhanyun Wang
- Institute of Environmental Engineering, ETH Zürich, 8093 Zürich, Switzerland
| | - Cailin Li
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Yuanyuan Yang
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Guang-Guo Ying
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Chang-Er Chen
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China.
| |
Collapse
|
17
|
Booij K. Passive Sampler Exchange Kinetics in Large and Small Water Volumes Under Mixed Rate Control by Sorbent and Water Boundary Layer. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2021; 40:1241-1254. [PMID: 33492717 DOI: 10.1002/etc.4989] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Revised: 11/02/2020] [Accepted: 01/15/2021] [Indexed: 06/12/2023]
Abstract
Exchange kinetics of organic compounds between passive samplers and water can be partly or completely controlled by transport in the sorbent. In such cases diffusion models are needed. A model is discussed that is based on a series of cosines (space) and exponentials (time). The model applies to mixed rate control by sorbent and water boundary layer under conditions of fixed aqueous concentrations (open systems, infinite water volumes, in situ sampling) and fixed amounts (closed systems, finite water volumes, ex situ sampling). Details on the implementation of the model in computational software and spreadsheet programs are discussed, including numerical accuracy. Key parameters are Biot number (ratio of internal/external transfer resistance) and sorbent/water phase ratio. Small Biot numbers are always indicative of rate control by the water boundary layer, but for large Biot numbers this may still be the case over short time scales. Application to environmental monitoring of nonpolar compounds showed that diffusion models are rarely needed for sampling with commonly used single-phase polymers. For determining sorption coefficients in batch incubations, the model demonstrated a profound effect of sorbent/water phase ratio on time to equilibrium. Application of the model to sampling of polar organic compounds by extraction disks with or without a membrane showed that moderate to major sorbent-controlled kinetics is likely to occur. This implies that the use of sampling rate models for such samplers needs to be reconsidered. Environ Toxicol Chem 2021;40:1241-1254. © 2021 SETAC.
Collapse
Affiliation(s)
- Kees Booij
- Passive Sampling of Organic Compounds, Kimswerd, The Netherlands
| |
Collapse
|
18
|
Valenzuela EF, de Paula FF, Teixeira APC, Menezes HC, Cardeal ZL. Assessment of pesticides in water using time-weighted average calibration of passive sampling device manufactured with carbon nanomaterial coating on stainless steel wire. Anal Bioanal Chem 2021; 413:3315-3327. [PMID: 33733701 DOI: 10.1007/s00216-021-03270-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 01/29/2021] [Accepted: 03/04/2021] [Indexed: 10/21/2022]
Abstract
The continued contamination of water sources by pesticides is a problem that involves the life of aquatic organisms and human health, especially in countries whose economy is based on agriculture. The need to know the quality of drinking water under these circumstances is a priority for the public health of any community. Passive sampling methods allow the determination of long-term environmental pollutants through a single sample collection, reducing time and cost of analyses. One advantage of passive sampling is that it is possible to calculate a time-weighted average (TWA) concentration value or an equilibrium concentration value, depending on the type of device used and the exposure time. Passive sampling techniques using carbon nanomaterials (CNMs) have a high potential for pesticide sampling in aquatic systems. A device for passive sampling manufactured with CNMs in a microextraction system and recyclable materials was calibrated in laboratory exposure conditions over 15 days. The calibration results showed linear accumulation periods between 5 and 10 days. Sampling rates were between 0.014 and 0.146 mL day-1. The sampler was field-tested in the San Francisco river basin in the state of Minas Gerais in Brazil for 7 days. This research allowed for the detection and calculation of TWA concentrations for organochlorine pesticides such as α-HCH, 4,4-DDE, and 4,4-DD in water sources. The manufactured device demonstrated greater sensitivity than the grab sampling processes for the detection of pesticides. The performed passive sampling system using gas chromatography/mass spectrometry (GC/MS) technique allowed for the collection, detection, identification, and quantification of 26 pesticides.
Collapse
Affiliation(s)
- Eduard F Valenzuela
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, Belo Horizonte, MG, 31270901, Brazil
| | - Fabiano F de Paula
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, Belo Horizonte, MG, 31270901, Brazil
| | - Ana Paula C Teixeira
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, Belo Horizonte, MG, 31270901, Brazil
| | - Helvécio C Menezes
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, Belo Horizonte, MG, 31270901, Brazil
| | - Zenilda L Cardeal
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, Belo Horizonte, MG, 31270901, Brazil.
| |
Collapse
|