1
|
Bhalla N, Shen AQ. Localized Surface Plasmon Resonance Sensing and its Interplay with Fluidics. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:9842-9854. [PMID: 38684953 PMCID: PMC11100005 DOI: 10.1021/acs.langmuir.4c00374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/18/2024] [Accepted: 04/20/2024] [Indexed: 05/02/2024]
Abstract
In this Feature Article, we discuss the interplay between fluidics and the localized surface plasmon resonance (LSPR) sensing technique, primarily focusing on its applications in the realm of bio/chemical sensing within fluidic environments. Commencing with a foundational overview of LSPR principles from a sensing perspective, we subsequently showcase the development of a streamlined LSPR chip integrated with microfluidic structures. This integration opens the doors to advanced experiments involving fluid dynamics, greatly expanding the scope of LSPR-based research. Our discussions then turn to the practical implementation of LSPR and microfluidics in real-time biosensing, with a specific emphasis on monitoring DNA polymerase activity. Additionally, we illustrate the direct sensing of biological fluids, exemplified by the analysis of urine, while also shedding light on a unique particle assembly process that occurs on LSPR chips. We not only discuss the significance of LSPR sensing but also explore its potential to investigate a plethora of phenomena at liquid-liquid and solid-liquid interfaces. This is particularly noteworthy, as existing transduction methods and sensors fall short in fully comprehending these interfacial phenomena. Concluding our discussion, we present a futuristic perspective that provides insights into potential opportunities emerging at the intersection of fluidics and LSPR sensing.
Collapse
Affiliation(s)
- Nikhil Bhalla
- Nanotechnology
and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, Belfast BT15 1AP, United Kingdom
- Healthcare
Technology Hub, School of Engineering, Ulster
University, Belfast BT15 1AP, United Kingdom
| | - Amy Q. Shen
- Micro/Bio/Nanofluidics
Unit, Okinawa Institute of Science and Technology
Graduate Univerisity, Onna-son, Okinawa 904-0495, Japan
| |
Collapse
|
2
|
Zhong Y, Yu H, Wen Y, Zhou P, Guo H, Zou W, Lv X, Liu L. Novel Optofluidic Imaging System Integrated with Tunable Microlens Arrays. ACS APPLIED MATERIALS & INTERFACES 2023; 15:11994-12004. [PMID: 36655899 DOI: 10.1021/acsami.2c20191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Optofluidic tunable microlens arrays (MLAs) can manipulate and control light propagation using fluids. Lately, their applicability to miniature lab-on-a-chip systems is being extensively researched. However, it is difficult to incorporate 3D MLAs directly in a narrow microfluidic channel using common techniques. This has resulted in limited research on variable focal length imaging with optofluidic 3D MLAs. In this paper, we propose a method for fabricating MLAs in polydimethylsiloxane (PDMS)-based microchannels via electrohydrodynamic jet (E-jet) printing to achieve optofluidic tunable MLAs. Using this method, MLAs of diameters 15 to 80 μm can be fabricated in microfluidic channels with widths of 200 and 300 μm. By alternately using solutions with different refractive indices in the microchannel, the optofluidic microlenses exhibit reversible modulation properties while retaining the morphologies and refractive indices of the microlenses. The focal length of the resulting optofluidic chip can have threefold tunability, thereby achieving an imaging depth of approximately 450 μm. This outstanding advantage is useful in observing microspheres and cells flowing in the microfluidic system. Thus, the proposed optofluidic chip exhibits great potential for cell counting and imaging applications.
Collapse
Affiliation(s)
- Ya Zhong
- State Key Laboratory of Robotics, Chinese Academy of Sciences, Shenyang Institute of Automation, Shenyang110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang110016, China
- University of Chinese Academy of Sciences, Beijing100049, China
| | - Haibo Yu
- State Key Laboratory of Robotics, Chinese Academy of Sciences, Shenyang Institute of Automation, Shenyang110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang110016, China
| | - Yangdong Wen
- Institute of Urban Rail Transportation, Southwest Jiaotong University, Chengdu610000, China
| | - Peilin Zhou
- College of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou450002, China
| | - Hongji Guo
- State Key Laboratory of Robotics, Chinese Academy of Sciences, Shenyang Institute of Automation, Shenyang110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang110016, China
| | - Wuhao Zou
- State Key Laboratory of Robotics, Chinese Academy of Sciences, Shenyang Institute of Automation, Shenyang110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang110016, China
- University of Chinese Academy of Sciences, Beijing100049, China
| | - Xiaofeng Lv
- State Key Laboratory of Robotics, Chinese Academy of Sciences, Shenyang Institute of Automation, Shenyang110016, China
- Northeastern University, Shenyang110016, China
| | - Lianqing Liu
- State Key Laboratory of Robotics, Chinese Academy of Sciences, Shenyang Institute of Automation, Shenyang110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang110016, China
| |
Collapse
|
3
|
Tang J, Qiu G, Cao X, deMello A, Wang J. Microfluid Switching-Induced Transient Refractive Interface. ACS Sens 2022; 7:3521-3529. [PMID: 36356161 DOI: 10.1021/acssensors.2c01901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The laminar flow interface (LFI) developed at low Reynolds numbers is one of the most prominent features of microscale flows and has been employed in a diverse range of optofluidic applications. The formation of LFIs usually requires the manipulation of multiple streams within a microchannel using a complex hydrodynamic pumping system. Herein, we present a new type of LFI that is generated by fluid switching within a three-dimensional (3D) microlens-incorporating microfluidic chip (3D-MIMC). Since Poiseuille flows exhibit a parabolic velocity profile, the LFI is cone-like in shape and acts as a transient refractive interface (TRI), which is sensitive to the refractive index (RI) and the Péclet number (Pe) of the switching fluids. In response to the TRI, the intensity of the transmitted light can be intensified or attenuated depending on the sequence of fluid switching operations. By incorporating three-dimensional (3D) microlenses and increasing the Pe values, the profile and amplitude of the intensity peak are both significantly improved. The limit of detection (LoD) for a sodium chloride (NaCl) solution at Pe = 1363 is as low as 0.001% (w/w), representing an improvement of 1-2 orders of magnitude when compared to existing optofluidic concentration sensors based on intensity modulation. Fluid switching of a variety of inorganic and organic sample fluids confirms that the specific optical response (Kor) correlates positively with both Pe and the specific RI (Knc), obeying a linear relationship. This model is further verified through cross-validations and used to estimate the molecular diffusion coefficient (D) of a range of species. Furthermore, by virtue of the TRI, we achieve a sensitive measurement of optical-equivalent total dissolved solids (OE-TDS) for environmental samples.
Collapse
Affiliation(s)
- Jiukai Tang
- Institute of Environmental Engineering, ETH Zürich, Zürich8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf8600, Switzerland
| | - Guangyu Qiu
- Institute of Environmental Engineering, ETH Zürich, Zürich8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf8600, Switzerland.,School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai200240, China
| | - Xiaobao Cao
- Institute of Chemical and Bioengineering, ETH Zürich, Zürich8093, Switzerland.,Guangzhou Lab, International Bio Island, Haizhu District, Guangzhou510005, Guangdong, China
| | - Andrew deMello
- Institute of Chemical and Bioengineering, ETH Zürich, Zürich8093, Switzerland
| | - Jing Wang
- Institute of Environmental Engineering, ETH Zürich, Zürich8093, Switzerland.,Laboratory for Advanced Analytical Technologies, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf8600, Switzerland
| |
Collapse
|
4
|
Yan R, Cui E, Zhao S, Zhou F, Wang D, Lei C. Real-time and high-sensitivity refractive index sensing with an arched optofluidic waveguide. OPTICS EXPRESS 2022; 30:16031-16043. [PMID: 36221456 DOI: 10.1364/oe.458280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Accepted: 04/11/2022] [Indexed: 06/16/2023]
Abstract
Refractive index (RI) sensing plays an important role in analytical chemistry, medical diagnosis, and environmental monitoring. The optofluidic technique is considered to be an ideal tool for RI sensor configuration for its high integration, high sensitivity, and low cost. However, it remains challenging to achieve RI measurement in real time with high sensitivity and low detection limit (DL) simultaneously. In this work, we design and fabricate a RI sensor with an arched optofluidic waveguide by monitoring the power loss of the light passing through the waveguide, which is sandwiched by the air-cladding and the liquid-cladding under test, we achieve RI detection of the sample in real time and with high sensitivity. Furthermore, both numerical simulation and experimental investigation show that our RI sensor can be designed with different geometric parameters to cover multiple RI ranges with high sensitivities for different applications. Experimental results illustrate that our sensor is capable to achieve a superior sensitivity better than -19.2 mW/RIU and a detection limit of 5.21×10-8 RIU in a wide linear dynamic range from 1.333 to 1.392, providing a promising solution for real-time and high-sensitivity RI sensing.
Collapse
|
5
|
Abstract
Optofluidics represents the interaction of light and fluids on a chip that integrates microfluidics and optics, which provides a promising optical platform for manipulating and analyzing fluid samples. Recent years have witnessed a substantial growth in optofluidic devices, including the integration of optical and fluidic control units, the incorporation of diverse photonic nanostructures, and new applications. All these advancements have enabled the implementation of optofluidics with improved performance. In this review, the recent advances of fabrication techniques and cutting-edge applications of optofluidic devices are presented, with a special focus on the developments of imaging and sensing. Specifically, the optofluidic based imaging techniques and applications are summarized, including the high-throughput cytometry, biochemical analysis, and optofluidic nanoparticle manipulation. The optofluidic sensing section is categorized according to the modulation approaches and the transduction mechanisms, represented by absorption, reflection/refraction, scattering, and plasmonics. Perspectives on future developments and promising avenues in the fields of optofluidics are also provided.
Collapse
|