1
|
Kruse RL, Neally M, Cho BC, Bloch EM, Lokhandwala PM, Ness PM, Frank SM, Tobian AAR, Gehrie EA. Cryoprecipitate Utilization Patterns Observed With a Required Prospective Approval Process vs Electronic Dosing Guidance. Am J Clin Pathol 2020; 154:362-368. [PMID: 32445461 DOI: 10.1093/ajcp/aqaa042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES We evaluated the impact of electronic medical record (EMR)-guided pooled cryoprecipitate dosing vs our previous practice of requiring transfusion medicine (TM) resident approval for every cryoprecipitate transfusion. METHODS At our hospital, cryoprecipitate pooled from five donors is dosed for adult patients, while single-donor cryoprecipitate is dosed for pediatric patients (defined as patients <50 kg in weight). EMR-based dosing guidance replaced a previously required TM consultation when cryoprecipitate pools were ordered, but a consultation remained required for single-unit orders. Usage was defined as thawed cryoprecipitate; wastage was defined as cryoprecipitate that expired prior to transfusion. RESULTS In the 6 months prior to intervention, 178 ± 13 doses of pooled cryoprecipitate were used per month vs 187 ± 15 doses after the intervention (P = .68). Wastage of pooled cryoprecipitate increased from 7.7% ± 1.5% to 12.7% ± 1.4% (P = .038). There was no change in wastage of pediatric cryoprecipitate doses during the study period. These trends remained unchanged for a full year postimplementation. CONCLUSIONS Electronic dosing guidance resulted in similar cryoprecipitate usage as TM auditing. Increased wastage may result from reduced TM oversight. Product wastage should be balanced against the possibility that real-time audits could delay a lifesaving therapy.
Collapse
Affiliation(s)
- Robert L Kruse
- Division of Transfusion Medicine, Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Melissa Neally
- Division of Transfusion Medicine, Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Brian C Cho
- Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Evan M Bloch
- Division of Transfusion Medicine, Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Parvez M Lokhandwala
- Division of Transfusion Medicine, Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Paul M Ness
- Division of Transfusion Medicine, Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Steven M Frank
- Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Aaron A R Tobian
- Division of Transfusion Medicine, Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Eric A Gehrie
- Division of Transfusion Medicine, Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD
| |
Collapse
|
2
|
Soril LJJ, Noseworthy TW, Dowsett LE, Memedovich K, Holitzki HM, Lorenzetti DL, Stelfox HT, Zygun DA, Clement FM. Behaviour modification interventions to optimise red blood cell transfusion practices: a systematic review and meta-analysis. BMJ Open 2018; 8:e019912. [PMID: 29776919 PMCID: PMC5961610 DOI: 10.1136/bmjopen-2017-019912] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
OBJECTIVE To assess the impact of behaviour modification interventions to promote restrictive red blood cell (RBC) transfusion practices. DESIGN Systematic review and meta-analysis. SETTING, PARTICIPANTS, INTERVENTIONS Seven electronic databases were searched to January 2018. Published randomised controlled trials (RCTs) or non-randomised studies examining an intervention to modify healthcare providers' RBC transfusion practice in any healthcare setting were included. PRIMARY AND SECONDARY OUTCOMES The primary outcome was the proportion of patients transfused. Secondary outcomes included the proportion of inappropriate transfusions, RBC units transfused per patient, in-hospital mortality, length of stay (LOS), pretransfusion haemoglobin and healthcare costs. Meta-analysis was conducted using a random-effects model and meta-regression was performed in cases of heterogeneity. Publication bias was assessed by Begg's funnel plot. RESULTS Eighty-four low to moderate quality studies were included: 3 were RCTs and 81 were non-randomised studies. Thirty-one studies evaluated a single intervention, 44 examined a multimodal intervention. The comparator in all studies was standard of care or historical control. In 33 non-randomised studies, use of an intervention was associated with reduced odds of transfusion (OR 0.63 (95% CI 0.56 to 0.71)), odds of inappropriate transfusion (OR 0.46 (95% CI 0.36 to 0.59)), RBC units/patient weighted mean difference (WMD: -0.50 units (95% CI -0.85 to -0.16)), LOS (WMD: -1.14 days (95% CI -2.12 to -0.16)) and pretransfusion haemoglobin (-0.28 g/dL (95% CI -0.48 to -0.08)). There was no difference in odds of mortality (OR 0.90 (95% CI 0.80 to 1.02)). Protocol/algorithm and multimodal interventions were associated with the greatest decreases in the primary outcome. There was high heterogeneity among estimates and evidence for publication bias. CONCLUSIONS The literature examining the impact of interventions on RBC transfusions is extensive, although most studies are non-randomised. Despite this, pooled analysis of 33 studies revealed improvement in the primary outcome. Future work needs to shift from asking, 'does it work?' to 'what works best and at what cost?' PROSPERO REGISTRATION NUMBER CRD42015024757.
Collapse
Affiliation(s)
- Lesley J J Soril
- Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
- O'Brien Institute for Public Health, The University of Calgary, Calgary, Alberta, Canada
| | - Thomas W Noseworthy
- O'Brien Institute for Public Health, The University of Calgary, Calgary, Alberta, Canada
| | - Laura E Dowsett
- Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
- O'Brien Institute for Public Health, The University of Calgary, Calgary, Alberta, Canada
| | - Katherine Memedovich
- Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
- O'Brien Institute for Public Health, The University of Calgary, Calgary, Alberta, Canada
| | - Hannah M Holitzki
- Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
- O'Brien Institute for Public Health, The University of Calgary, Calgary, Alberta, Canada
| | - Diane L Lorenzetti
- Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
- O'Brien Institute for Public Health, The University of Calgary, Calgary, Alberta, Canada
| | - Henry Thomas Stelfox
- Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
- O'Brien Institute for Public Health, The University of Calgary, Calgary, Alberta, Canada
- Department of Critical Care Medicine, Cumming School of Medicine, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada
- Critical Care Strategic Clinical Network, Alberta Health Services, Edmonton, Alberta, Canada
| | - David A Zygun
- Critical Care Strategic Clinical Network, Alberta Health Services, Edmonton, Alberta, Canada
- Department of Critical Care Medicine, Alberta Health Services and Faculty of Medicine and Dentistry, University of Alberta, Calgary, Alberta, Canada
| | - Fiona M Clement
- Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
- O'Brien Institute for Public Health, The University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
3
|
Lanzoni M, Olivero B, Artoni A, Marconi M, Raspollini E, Castaldi S. Use of fresh-frozen plasma in 2012 at the Fondazione Ca' Granda Hospital of Milan: assessment of appropriateness using record linkage techniques applied to data routinely recorded in various hospital information systems. BLOOD TRANSFUSION = TRASFUSIONE DEL SANGUE 2018; 16:253-261. [PMID: 28686150 PMCID: PMC5919837 DOI: 10.2450/2017.0309-16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 05/15/2017] [Indexed: 11/21/2022]
Abstract
BACKGROUND The Quality Unit of a research and teaching hospital in Milan assessed the increased clinical use of fresh-frozen plasma in patients treated during 2012 in order to evaluate the appropriateness of this use. MATERIALS AND METHODS For each patient in the study, a pathology profile was generated by means of record linkage techniques involving data collected through different information systems. Patients' information was combined using the patient identifier key generating pathology profiles exported to an Excel file. The profiles were reviewed by two haematologists who identified 101 potentially inappropriate treatments for which the medical records had to be reviewed manually. RESULTS In 2012, 490 patients were transfused and for 473 cases the automatic record linkage provided a complete profile. The information relating to the remaining patients did not match, mainly because the patients underwent outpatient procedures for which clinical information is not automatically recorded. In the overall audit only 13 treatments were judged inappropriate. DISCUSSION Our study supports the view that record linkage techniques applied to data routinely recorded in different hospital information systems could be potentially extended to support clinical audits, enabling the generation of automated patient profiles that can be easily evaluated, relegating manual checks on medical records to doubtful cases only. Moreover, the method applied in this study allows the analysis of a full set of cases instead of sample surveys, increasing the robustness of the audit results.
Collapse
Affiliation(s)
- Monica Lanzoni
- Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Barbara Olivero
- Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Andrea Artoni
- Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Maurizio Marconi
- Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
| | | | - Silvana Castaldi
- Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
- Department of Biomedical Sciences for Health, University of Milan, Milan, Italy
| |
Collapse
|
4
|
Arnold DM, Lauzier F, Whittingham H, Zhou Q, Crowther MA, McDonald E, Cook DJ. A multifaceted strategy to reduce inappropriate use of frozen plasma transfusions in the intensive care unit. J Crit Care 2011; 26:636.e7-636.e13. [PMID: 21439762 DOI: 10.1016/j.jcrc.2011.02.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2010] [Revised: 02/09/2011] [Accepted: 02/13/2011] [Indexed: 11/17/2022]
Abstract
PURPOSE The purpose of this study is to determine the effect of a multifaceted behavior-change strategy on inappropriate use of frozen plasma (FP) transfusions in the intensive care unit (ICU). MATERIALS AND METHODS A prospective, time-series study was conducted in a 15-bed medical-surgical ICU in 3 phases: (1) baseline observation; (2) educational campaign, audit and feedback to prescribers, and implementation of an FP request form; and (3) FP request form only. Independently, in triplicate and blinded to study phase, appropriateness of each FP request was adjudicated based on published guidelines and clinical context. RESULTS Over the 15-month study period, 626 FP transfusions (210 FP requests) were administered to 88 patients. Inappropriate FP requests decreased slightly from phases I to III (60% vs 46%; P = .09), FP requests that were consistent with the guidelines did not change (23% vs 22%; P = .86), and FP requests that were appropriate for the ICU yet inconsistent with the guidelines increased (17% vs 32%; P = .04). Although uptake of the FP request form decreased in phase III, it was associated with fewer inappropriate transfusions. CONCLUSIONS The behavior-change strategy modestly improved appropriate use of FP transfusions in the ICU. Improving FP request form accuracy, completeness, and compliance may be required to achieve maximum effect and ensure sustainability.
Collapse
Affiliation(s)
- Donald M Arnold
- Department of Medicine, McMaster University, Hamilton, Ontario, Canada L8N 3Z5.
| | | | | | | | | | | | | |
Collapse
|
5
|
Damiani G, Pinnarelli L, Sommella L, Farelli V, Mele L, Menichella G, Ricciardi W. Appropriateness of fresh-frozen plasma usage in hospital settings: a meta-analysis of the impact of organizational interventions. Transfusion 2010; 50:139-44. [DOI: 10.1111/j.1537-2995.2009.02371.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
6
|
Plasma frais congelé et apport transfusionnel en chirurgie cardiaque. Ing Rech Biomed 2009. [DOI: 10.1016/s1959-0318(09)74601-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
7
|
Tuscan study on the appropriateness of fresh-frozen plasma transfusion (TuSAPlaT). BLOOD TRANSFUSION = TRASFUSIONE DEL SANGUE 2007; 5:75-84. [PMID: 19204757 DOI: 10.2450/2007.0015-07] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 04/24/2007] [Accepted: 06/04/2007] [Indexed: 11/21/2022]
Abstract
INTRODUCTION The considerable increase in the consumption of fresh-frozen plasma (FFP) recorded in 2002 in the Region of Tuscany made it necessary to check the appropriateness of the use of this blood component in all transfusion facilities in the Tuscan network. MATERIALS AND METHODS From July 1, 2003 to December 31, 2005, the Regional Blood Transfusion Coordinating Centre carried out an audit on the clinical use of FFP in the 40 structures included in the Tuscan transfusion network. The study had two complementary parts: a review of guidelines on the use of FFP and the involvement of Hospital Transfusion Committees in evaluating the outcome of the audit and in the consequent local policy decisions and in educating clinicians. RESULTS The data from all 40 of the regional transfusion structures were analysed. The audit, which was initially retrospective, gradually became prospective. The percentage clinical use of FFP decreased, compared to 2002, in each of the 3 years of the study: a) 2003: - 8.92%; b) 2004: - 2.11%; c) 2005: -1.97%. The inappropriate requests for plasma decreased from 27% to 22.7% of the total. It was possible to classify the inappropriate requests for plasma on the basis of homogeneous, regionally defined criteria. The most frequent inappropriate indication (60.7% of the total) was the use of plasma in the case of haemorrhage in patients with a normal PT and/or PTT or unavailable results. Each hospital revised its own guidelines between 2004 and 2005 and the Hospital Transfusion Committees set up appropriate educational and behavioural interventions. CONCLUSIONS The capacity of transfusion facilities to make data on the use of blood components available systematically and continuously is an essential feature of clinical governance; systematic clinical auditing increases the level of appropriate behaviours in the transfusion sector, contemporaneously contributing to self-sufficiency in transfusion products, and may direct research towards those clinical settings at greatest risk of inappropriate use of transfusion therapy with FFP.
Collapse
|
8
|
Battles JB, Wilkinson SL, Lee SJ. Using standardised patients in an objective structured clinical examination as a patient safety tool. Qual Saf Health Care 2004. [PMID: 15465955 DOI: 10.1136/qshc.2004.009803] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Standardised patients (SPs) are a powerful form of simulation that has now become commonplace in training and assessment in medical education throughout the world. Standardised patients are individuals, with or without actual disease, who have been trained to portray a medical case in a consistent manner. They are now the gold standard for measuring the competence of physicians and other health professionals, and the quality of their practice. A common way in which SPs are used in performance assessment has been as part of an objective structured clinical examination (OSCE). The use of an SP based OSCE can be a powerful tool in measuring continued competence in human reliability and skill performance where such skills are a critical attribute to maintaining patient safety. This article will describe how an OSCE could be used as a patient safety tool based on cases derived from actual events related to postdonation information in the blood collection process. The OSCE was developed as a competency examination for health history takers. Postdonation information events in the blood collection process account for the majority of errors reported to the US Food and Drug Administration. SP based assessment is an important patient safety tool that could be applied to a variety of patient safety settings and situations, and should be considered an important weapon in the war on medical error and patient harm.
Collapse
Affiliation(s)
- J B Battles
- University of Texas Southwestern Medical Center at Dallas, USA.
| | | | | |
Collapse
|
9
|
Battles JB, Wilkinson SL, Lee SJ. Using standardised patients in an objective structured clinical examination as a patient safety tool. Qual Saf Health Care 2004; 13 Suppl 1:i46-50. [PMID: 15465955 PMCID: PMC1765798 DOI: 10.1136/qhc.13.suppl_1.i46] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Standardised patients (SPs) are a powerful form of simulation that has now become commonplace in training and assessment in medical education throughout the world. Standardised patients are individuals, with or without actual disease, who have been trained to portray a medical case in a consistent manner. They are now the gold standard for measuring the competence of physicians and other health professionals, and the quality of their practice. A common way in which SPs are used in performance assessment has been as part of an objective structured clinical examination (OSCE). The use of an SP based OSCE can be a powerful tool in measuring continued competence in human reliability and skill performance where such skills are a critical attribute to maintaining patient safety. This article will describe how an OSCE could be used as a patient safety tool based on cases derived from actual events related to postdonation information in the blood collection process. The OSCE was developed as a competency examination for health history takers. Postdonation information events in the blood collection process account for the majority of errors reported to the US Food and Drug Administration. SP based assessment is an important patient safety tool that could be applied to a variety of patient safety settings and situations, and should be considered an important weapon in the war on medical error and patient harm.
Collapse
Affiliation(s)
- J B Battles
- University of Texas Southwestern Medical Center at Dallas, USA.
| | | | | |
Collapse
|
10
|
Petäjä J, Andersson S, Syrjälä M. A simple automatized audit system for following and managing practices of platelet and plasma transfusions in a neonatal intensive care unit. Transfus Med 2004; 14:281-8. [PMID: 15285724 DOI: 10.1111/j.0958-7578.2004.00515.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
During neonatal intensive care, blood components are often used in clinical situations where both their efficacy and safety lack solid justification. A practical system to continuously analyse actual transfusion practices is a prerequisite for improvements of quality in transfusion therapy. We hypothesized that such a system would reveal inappropriate variations in clinical decision making and offer a means for staff education and quality improvement and assurance. The study consisted of three 120-152-day periods (P I, P II and P III) between January 2000 and October 2001 and involved 543 new patient admissions (141 patients with birth weight < 1501 g) and 6227 days of patient care at a single tertiary level NICU. P I was a control with no intervention, P II was after technically introducing the computer system and, the last period, P III was after presenting and discussing the results of P I and P II at a staff meeting. Upon an order of platelet or fresh frozen plasma (FFP) unit from the blood bank, a computer-based audit system compared the last platelet count or prothrombin time [expressed as percentage of normal clotting activity, prothrombin time (PT-%)] to predefined criteria. In the case of exceeding the preset thresholds, the system required additional information and recorded the pretransfusion laboratory values for later analysis. Thirty-two per cent of platelet transfusions were given with pretransfusion platelet count >49 x 10(9) L(-1), and 60% of these transfusions (19% of all platelet transfusions) could not be clinically justified in retrospective chart review. There was no significant change in this practice from P II to P III. FFP transfusions were given with significantly different pretransfusion PT-% values during P II and P III. The proportions of FFP transfusions with pretransfusion PT-% > 49% were 7.8% and 0.9% during P II and P III, respectively (P < 0.0001). In chart review, none of the FFP transfusions with pretransfusion PT-% > 49% could be justified by clinical grounds. Inappropriate transfusions of both platelets and plasma remain a significant challenge for quality assurance of neonatal intensive care. Automated recording of pretransfusion platelet count and prothrombin time reliably identified the poorly justified transfusions and thus offered a practical resource-saving tool for quality assurance of transfusion in the NICU. A significant shift towards more appropriate use of plasma was demonstrated after implementation of the audit system.
Collapse
Affiliation(s)
- J Petäjä
- Hospital for Children and Adolescents, Helsinki University Central Hospital, Helsinki, Finland.
| | | | | |
Collapse
|
11
|
Pentti J, Syrjälä M, Pettilä V. Computerized quality assurance of decisions to transfuse blood components to critically ill patients. Acta Anaesthesiol Scand 2003; 47:973-8. [PMID: 12904189 DOI: 10.1034/j.1399-6576.2003.00203.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND In critically ill patients optimal transfusion therapy for most clinical settings has not been determined. The objective of this study was to evaluate the impact of a computerized audit on transfusion decisions of red blood cells (RBC), fresh frozen plasma (FFP), and platelets among critically ill patients. METHODS Two hundred and ninety consecutive patients admitted to nine-bed medical-surgical intensive care unit at a university hospital were included in this prospective study. Prior to the study, the criteria for transfusions of RBCs, FFP and platelets were established. Phase I, the first 3-month period served as a control period. During phase II the fulfilment of these criteria was prospectively monitored by an audit software belonging to the computerized blood request program. If the predefined transfusion criteria were not met the audit software was automatically activated. The last 3-month period, phase III, was to assess if possible effects on transfusion decisions were permanent. RESULTS The proportion of RBC transfusions administered according to predefined trigger during the study phases I, II, and III were 55.9%, 75.1% and 67.9%, respectively (P < 0.001). The proportion of FFP and platelet transfusions according to a predefined trigger did not differ statistically significantly between the study phases. Logistic multiple regression analysis revealed an independent effect of the audit phase on the decision to transfuse RBCs and FFP. CONCLUSIONS The data suggests that a computerized prospective transfusion audit has impact on the realisation of predefined transfusion decisions.
Collapse
Affiliation(s)
- J Pentti
- Department of Anaesthesiology and Intensive Care Medicine, Central Hospital of Kymenlaakso, Kotka, Finland.
| | | | | |
Collapse
|
12
|
Lee SJ, Wilkinson SL, Battles JB, Hynan LS. An objective structured clinical examination to evaluate health historian competencies. Transfusion 2003; 43:34-41. [PMID: 12519428 DOI: 10.1046/j.1537-2995.2003.00275.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Post-donation information events in the blood-collection process account for the majority of errors reported to the FDA. An eight-station objective structured clinical examination (OSCE) based on information reported after donation was developed as a competency examination for health historians. STUDY DESIGN AND METHODS The OSCE measured two individual skill components: history-taking technique (HXE) and ability to record and interpret a medical history (HXI). Donor historians at the Hoxworth Blood Center, University of Cincinnati Medical Center, were examined (n = 56). RESULTS In general, staff performance was acceptable, but several areas for improvement were identified. Of particular concern were the deferrals associated with the malaria scenarios. The overall reliability score was greater than 0.8 for the total OSCE and HXI. Using the cut score of 0.9, or 90 percent, 10 subjects would not have passed the exam based on the HXE score and one person would not have demonstrated competency based on the HXI score. CONCLUSION An OSCE is a reliable, valid, and practical method for assessing continued competency in health historians. This form of competency assessment and subsequent retraining may reduce the incidence of errors in information reported after donation and should be further studied as a suitable national standard for assessing competency.
Collapse
Affiliation(s)
- Stacy J Lee
- Blood Center of Southeastern Wisconsin, Milwaukee, 53233-2121, USA.
| | | | | | | |
Collapse
|
13
|
Affiliation(s)
- J P Wallis
- Haematology Department, Freeman Hospital, High Heaton, Newcastle Upon Tyne, UK.
| | | | | |
Collapse
|
14
|
Beloeil H, Brosseau M, Benhamou D. [Transfusion of fresh frozen plasma (FFP): audit of prescriptions]. ANNALES FRANCAISES D'ANESTHESIE ET DE REANIMATION 2001; 20:686-92. [PMID: 11695287 DOI: 10.1016/s0750-7658(01)00462-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVE To review fresh frozen plasma (FFP) prescriptions and compare their validity to the legal french guidelines (law of the 12/03/91). STUDY DESIGN Assessment of all prescriptions has been carried out by a multidisciplinary committee. PATIENTS All the adults transfused with FFP over one year in a teaching hospital. METHODS Following each head of department's agreement and following a written notice to all prescribers within the hospital to inform them of the undergoing study and its methodological validation by the board of quality experts, each delivery of FFP was followed by a questionnaire addressed to the prescriber. A board of experts then assessed the significance of the prescription in accordance with the legal requirements after reviewing each medical file. RESULTS 144 prescriptions to 89 patients were assessed: 23% were judged inappropriate by the experts and 6% did not respect the law. The inappropriate transfusions distribute as follows: intensive care patients (73% of which 80% in multiple organ failure (MOF) and 20% in haemorrhagic shock), cirrhotic patients (12%), patients treated with vitamin K antagonists (12%), obstetric patients (3%). Nine percent of the appropriate transfusions were judged in insufficient volume. The hospital mortality rate was 48%. Among prescribers, 59% were not aware of the law. CONCLUSION A significant proportion of FFP transfusions is inappropriate. This study, which is the first step of a quality assurance program, will be followed by local recommendations for clinical practice. The current standards of prescribing FFP are more restrictive than those defined in the legal french guidelines.
Collapse
Affiliation(s)
- H Beloeil
- Département d'anesthésie-réanimation, hôpital Antoine-Béclère, BP 405, 92141 Clamart, France
| | | | | |
Collapse
|
15
|
Achour SL, Dojat M, Rieux C, Bierling P, Lepage E. A UMLS-based knowledge acquisition tool for rule-based clinical decision support system development. J Am Med Inform Assoc 2001; 8:351-60. [PMID: 11418542 PMCID: PMC130080 DOI: 10.1136/jamia.2001.0080351] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2000] [Accepted: 03/14/2001] [Indexed: 11/04/2022] Open
Abstract
Decision support systems in the medical field have to be easily modified by medical experts themselves. The authors have designed a knowledge acquisition tool to facilitate the creation and maintenance of a knowledge base by the domain expert and its sharing and reuse by other institutions. The Unified Medical Language System (UMLS) contains the domain entities and constitutes the relations repository from which the expert builds, through a specific browser, the explicit domain ontology. The expert is then guided in creating the knowledge base according to the pre-established domain ontology and condition-action rule templates that are well adapted to several clinical decision-making processes. Corresponding medical logic modules are eventually generated. The application of this knowledge acquisition tool to the construction of a decision support system in blood transfusion demonstrates the value of such a pragmatic methodology for the design of rule-based clinical systems that rely on the highly progressive knowledge embedded in hospital information systems.
Collapse
Affiliation(s)
- S L Achour
- Department of Hospital Information, Henri Mondor Hospital, Créteil, France.
| | | | | | | | | |
Collapse
|
16
|
Abstract
Guiding the decision to transfuse can improve transfusion practices. Effective processes must first identify problem(s) in transfusion practice and then include the attending physician as an educational target. Process improvements that have been shown to be effective include the following: (1) briefly meeting one-on-one with physicians, (2) teaching at scheduled conferences, (3) making daily clinical rounds of patients who receive transfusion, (4) concurrently reviewing orders for transfusion before issue of the blood product, and (5) installing algorithms and guidelines in the operating room. Transfusion practices improved with these process improvements.
Collapse
Affiliation(s)
- P Toy
- Department of Laboratory Medicine, University of California, San Francisco, USA
| |
Collapse
|
17
|
Zimmermann R, Handtrack D, Zingsem J, Weisbach V, Neidhardt B, Glaser A, Eckstein R. A survey of blood utilization in children and adolescents in a German university hospital. Transfus Med 1998; 8:185-94. [PMID: 9800290 DOI: 10.1046/j.1365-3148.1998.00159.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
There are no detailed data on blood use with regard to diagnoses of recipients during infancy, childhood and adolescence. Available information on this issue is incomplete and no longer current. We conducted a survey of blood component use in children and adolescents in an acute-care university hospital in the greater area of Nuremberg between June 1994 and September 1996. Packed red blood cells (RBCs), fresh-frozen plasmas (FFPs) and platelet (PLT) components were evaluated for the recipients discharge diagnoses. Source study files were extracted from the hospital transfusion service and the medical records department. Transfused units were listed by broad diagnostic categories and leading diagnostic groups formed from principal diagnoses of the recipients according to the International Classification of Diseases, 9th edn (ICD-9). 34.3% of 2869 RBC cell units, 35.0% of 1095 FFP units and 5.0% of 1028 PLT components were used in patients with congenital diseases, mainly cardiac defects. The disease category neoplastic diseases was next most frequently associated with blood transfusion diagnosed in recipients of 23.9% of all RBCs, 15.6% of all FFP units and in 66.4% of all PLT units. Malignant diseases and benign haematological diseases (diagnostic categories II and IV) accounted for 68.9% of all costs of blood component transfusion. These findings demonstrate the increased importance of platelet transfusion for the organization of local and regional blood donation programmes and for cost analysis exercises. The study shows that detailed information on local blood use may be obtained quickly using available data collections of transfusion services and medical record departments.
Collapse
Affiliation(s)
- R Zimmermann
- Abteilung für Transfusionsmedizin und Hämostaseologie, Friedrich-Alexander-Universität, Erlangen-Nürnberg, Germany.
| | | | | | | | | | | | | |
Collapse
|
18
|
Abstract
Audits of transfusion used as educational tools can improve transfusion practices. Effective audits must first identify problem(s) in transfusion practice and must then include as educational target, the attending physician. Educational methods that have been shown to the effective include: (1) meeting briefly one-on-one with physicians, (2) teaching at scheduled conferences, (3) making daily clinical rounds on patients who receive transfusion, (4) concurrent review of orders for transfusion prior to issue of the blood product and (5) installing algorithms and guidelines in the operating room. Transfusion practices improved with these educational audit methods.
Collapse
Affiliation(s)
- P Toy
- University of California, San Francisco 94143, USA
| |
Collapse
|
19
|
Kanter MH. The transfusion audit as a tool to improve transfusion practice: a critical appraisal. TRANSFUSION SCIENCE 1998; 19:69-81. [PMID: 10182184 DOI: 10.1016/s0955-3886(98)00012-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Transfusion audits have a long history and they are required by many regulatory agencies. These audits have been touted as effective in reducing unnecessary transfusions as evidenced by many published articles on the subject. Most of these studies, however, have one or more flaws in their design including the use of historical controls, disregard of the Hawthorne effect, use of multiple interventions, and publication bias. Studies differ in the baseline rate of inappropriate transfusions and have different methods of measuring these rates. There is also little data on how long the effect of implementing a transfusion audit system may last. Transfusion audits appear most successful when there is a high baseline rate of inappropriate transfusions and interventions other than the audit itself are performed. Individual institutions should critically evaluate whether or not their current system of transfusion audits is useful.
Collapse
Affiliation(s)
- M H Kanter
- Southern California Permanent Medical Group, Department of Pathology, Kaiser Permanente, Woodland Hills, CA 91365, USA.
| |
Collapse
|
20
|
Tuckfield A, Haeusler MN, Grigg AP, Metz J. Reduction of inappropriate use of blood products by prospective monitoring of transfusion request forms. Med J Aust 1997; 167:473-6. [PMID: 9397061 DOI: 10.5694/j.1326-5377.1997.tb126674.x] [Citation(s) in RCA: 51] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To determine the effect of prospective monitoring on appropriateness of transfusions of red cells, platelets and fresh frozen plasma (FFP). DESIGN Prospective interventional study. SETTING Royal Melbourne Hospital (a tertiary teaching hospital), Melbourne, Victoria, March-May 1996. INTERVENTION The blood product request form was modified to incorporate indications for transfusion and clinical and laboratory data. Requests were monitored by blood bank laboratory staff for conformation with hospital transfusion guidelines; non-conforming requests were discussed with the requesting medical practitioner by the Haematology Registrar before blood products were issued. In case of disagreement, blood products were always issued. SUBJECTS 200 consecutive transfusion episodes for each product (red cells, platelets and FFP). OUTCOME MEASURES Appropriateness of transfusion, assessed by a Consultant Haematologist according to hospital guidelines. Rates of inappropriate transfusion episodes after intervention were compared with rates in a previous study. RESULTS After intervention, rates of inappropriate transfusion episodes fell significantly (red cells, 16% to 3% [P = 0.004]; platelets, 13% to 2.5% [P = 0.02]; and FFP, 31% to 15% [P = 0.02]). Almost all inappropriate FFP transfusion episodes post-intervention were due to failure to demonstrate prolongation of prothrombin or activated partial thromboplastin times more than 1.5 times the control value. CONCLUSION Prospective monitoring of request forms can reduce rates of inappropriate transfusions. High rates of inappropriate FFP transfusions possibly reflect uncertainty about appropriate laboratory criteria for FFP transfusion. While results of large prospective randomised controlled clinical trials of FFP transfusions are awaited, currently laboratory criteria can be retained, but should be applied with flexibility.
Collapse
Affiliation(s)
- A Tuckfield
- Department of Diagnostic Haematology, Royal Melbourne Hospital, VIC
| | | | | | | |
Collapse
|
21
|
Williamson LM, Heptonstall J, Soldan K. A SHOT in the arm for safer blood transfusion. BMJ (CLINICAL RESEARCH ED.) 1996; 313:1221-2. [PMID: 8939097 PMCID: PMC2352538 DOI: 10.1136/bmj.313.7067.1221] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
22
|
SIRCHIA GIROLAMO. BLOOD TRANSFUSION IN THE 21 ST CENTURY: HOSPITAL. Vox Sang 1996. [DOI: 10.1111/j.1423-0410.1996.tb01381.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|