1
|
Mercado LA, Gil-Lopez F, Chirila RM, Harnois DM. Autoimmune Hepatitis: A Diagnostic and Therapeutic Overview. Diagnostics (Basel) 2024; 14:382. [PMID: 38396421 PMCID: PMC10887775 DOI: 10.3390/diagnostics14040382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 02/02/2024] [Accepted: 02/06/2024] [Indexed: 02/25/2024] Open
Abstract
Autoimmune hepatitis is an immune-mediated inflammatory condition of the liver of undetermined cause that affects both sexes, all ages, races, and ethnicities. Its clinical presentation can be very broad, from having an asymptomatic and silent course to presenting as acute hepatitis, cirrhosis, and acute liver failure potentially requiring liver transplantation. The diagnosis is based on histological abnormalities (interface hepatitis), characteristic clinical and laboratory findings (increased aspartate aminotransferase, alanine aminotransferase, and serum IgG concentration), and the presence of one or more characteristic autoantibodies. The large heterogeneity of these clinical, biochemical, and histological findings can sometimes make a timely and proper diagnosis a difficult task. Treatment seeks to achieve remission of the disease and prevent further progression of liver disease. First-line therapy includes high-dose corticosteroids, which are later tapered to decrease side effects, and azathioprine. In the presence of azathioprine intolerance or a poor response to the standard of care, second-line therapy needs to be considered, including mycophenolate mofetil. AIH remains a diagnostic and therapeutic challenge, and a further understanding of the pathophysiological pathways of the disease and the implementation of randomized controlled trials are needed.
Collapse
Affiliation(s)
- Lydia A. Mercado
- Department of Liver Transplant, Mayo Clinic Florida, Jacksonville, FL 32224, USA
| | - Fernando Gil-Lopez
- Department of Liver Transplant, Mayo Clinic Florida, Jacksonville, FL 32224, USA
| | - Razvan M. Chirila
- Department of General Internal Medicine, Mayo Clinic Florida, Jacksonville, FL 32224, USA;
| | - Denise M. Harnois
- Department of Liver Transplant, Mayo Clinic Florida, Jacksonville, FL 32224, USA
- Department of Gastroenterology and Hepatology, Mayo Clinic Florida, Jacksonville, FL 32224, USA
| |
Collapse
|
2
|
Schambeck JPL, Forte GC, Gonçalves LM, Stuker G, Kotlinski JBF, Tramontin G, Altmayer S, Watte G, Hochhegger B. Diagnostic accuracy of magnetic resonance elastography and point-shear wave elastography for significant hepatic fibrosis screening: Systematic review and meta-analysis. PLoS One 2023; 18:e0271572. [PMID: 36730265 PMCID: PMC9894488 DOI: 10.1371/journal.pone.0271572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 07/03/2022] [Indexed: 02/03/2023] Open
Abstract
The hepatic diseases are extremely common in clinical practice. The correct classification of liver fibrosis is extremely important, as it influences therapy and predicts disease outcomes. The purpose of this study is to compare the diagnostic performance of point-shear wave elastography (pSWE) and magnetic resonance elastography (MRE) in the hepatic fibrosis diagnostic. A meta-analysis was carried out based on articles published until October 2020. The articles are available at following databases: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Scientific Electronic Library Online, LILACS, Scopus, and CINAHL. Diagnostic performances were analyzed per METAVIR F2, using 3.5kPa as target fibrosis. Assessment of the methodological quality of the incorporated papers by the QUADAS-2 tool for pSWE and MRE. A total 2,153 studies articles were evaluated and 44 studies, comprising 6,081 patients with individual data, were included in the meta-analysis: 28 studies for pSWE and 16 studies for MRE. The pooled sensitivity and specificity were 0.86 (95%CI 0.80-0.90) and 0.88 (95%CI 0.85-0.91), respectively, for pSWE, compared with 0.94 (95%CI 0.89-0.97) and 0.95 (95%CI 0.89-0.98) respectively, for MRE. The pooled SROC curve for pSWE shows in the area under the curve (AUC) of 0.93 (95%CI 0.90-0.95), whereas the AUC for MRE was 0.98 (95%CI 0.96-0.99). The diagnostic odds ratio for pSWE and MRE were 41 (95%CI 24-72) and 293 (95%CI 86-1000), respectively. There was statistically significant heterogeneity for pSWE sensitivity (I² = 85.26, P<0.001) and specificity (I² = 89.46, P<0.001). The heterogeneity for MRE also was significant for sensitivity (I² = 73.28, P<0.001) and specificity (I² = 87.24, P<0.001). Therefore, both pSWE and MRE are suitable modalities for assessing liver fibrosis. In addition, MRE is a more accurate imaging technique than pSWE and can be used as alternative to invasive biopsy.
Collapse
Affiliation(s)
- João Paulo L. Schambeck
- Post-Graduate Program in Medicine and Health Science, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Gabriele C. Forte
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Faculty of Medicine, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- * E-mail:
| | - Luana M. Gonçalves
- Post-Graduate Program in Medicine and Health Science, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Guilherme Stuker
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - João Bruno F. Kotlinski
- Faculty of Medicine, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Giacomo Tramontin
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Stephan Altmayer
- Post-Graduate Program in Medicine and Health Science, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Guilherme Watte
- Department of Radiology, Medical Imaging Research Lab, LABIMED, Porto Alegre, Rio Grande do Sul, Brazil
| | - Bruno Hochhegger
- Post-Graduate Program in Medicine and Health Science, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Department of Radiology, Medical Imaging Research Lab, LABIMED, Porto Alegre, Rio Grande do Sul, Brazil
- Department of Diagnostic Methods, Federal University of Health Sciences of Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil
| |
Collapse
|
3
|
Pennisi G, Celsa C, Giammanco A, Spatola F, Petta S. The Relevance of Noninvasive Tools To Assess Fibrosis in Non-Alcoholic Fatty Liver Disease. Curr Pharm Des 2021; 26:3928-3938. [PMID: 32436818 DOI: 10.2174/1381612826666200521133307] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 04/16/2020] [Indexed: 12/15/2022]
Abstract
Non-alcoholic fatty liver disease (NAFLD) is a growing cause of chronic liver diseases worldwide, involving about 25% of people. NAFLD incorporates a large spectrum of pathological conditions, from simple steatosis to non-alcoholic steatohepatitis (NASH), cirrhosis and its complications include hepatic decompensation and hepatocellular carcinoma (HCC). This progression occurs, over many years, in an asymptomatic way, until advanced fibrosis appears. Thus, the differentiation of NASH from simple steatosis and identification of advanced hepatic fibrosis are key issues. To date, the histological assessment of fibrosis with liver biopsy is the gold standard, but obviously, invasiveness is the greater threshold. In addition, rare but potentially life-threatening complications, poor acceptability, sampling variability and cost maybe restrict its use. Furthermore, due to the epidemic of NAFLD worldwide and several limitations of liver biopsy evaluation, noninvasive assessment tools to detect fibrosis in NAFLD patients are needed.
Collapse
Affiliation(s)
- Grazia Pennisi
- Sezione di Gastroenterologia e Epatologia, PROMISE, University of Palermo, Palermo, Italy
| | - Ciro Celsa
- Sezione di Gastroenterologia e Epatologia, PROMISE, University of Palermo, Palermo, Italy
| | - Antonina Giammanco
- Department of Health Promotion Sciences Maternal and Infantile Care, Internal Medicine and Medical Specialities, University of Palermo, Palermo, Italy
| | - Federica Spatola
- Sezione di Gastroenterologia e Epatologia, PROMISE, University of Palermo, Palermo, Italy
| | - Salvatore Petta
- Sezione di Gastroenterologia e Epatologia, PROMISE, University of Palermo, Palermo, Italy
| |
Collapse
|
4
|
Shear-wave velocity for colorectal cancer liver metastases as a potential prognostic factor after chemotherapy: a preliminary study. Clin Radiol 2021; 76:224-232. [PMID: 33402260 DOI: 10.1016/j.crad.2020.09.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Accepted: 09/30/2020] [Indexed: 11/21/2022]
Abstract
AIM To evaluate whether shear-wave velocity (SWV) can be used for predicting the prognoses of patients with colorectal cancer liver metastases (CRLMs) after chemotherapy. MATERIALS AND METHODS Our institutional review board approved this prospective study, and written informed consent was obtained. SWV of CRLMs were obtained using point shear-wave elastography using acoustic radiation force impulse from 25 patients prior to and 2, 7, and 14 days after chemotherapy. Progression-free survival (PFS) after chemotherapy was estimated using the Kaplan-Meier method. The Cox proportional hazard regression model was used to determine significant predictive factors for PFS. For measurement reproducibility, an additional 37 patients with CRLMs were enrolled and assessed using intraclass correlation coefficients (ICCs). RESULTS After chemotherapy, 10 and 15 patients were classified into responder and non-responder groups, respectively. The estimated 1- and 3-year PFS values in the whole cohort were 36% and 8%, respectively. A decrease in the SWV value on day 2 relative to the initial value was a significant predictive factor for better PFS outcome (hazard ratio = 0.20, 95% confidence interval = 0.07-0.57, p=0.003). The estimated 1 and 3-year PFS rates were 66.7% and 22.2%, respectively, in nine patients with decreased SWV values on day 2 and significantly higher than 18.8% and 0% of 16 patients with increased SWV values on day 2. The ICC value of SWV of CRLMs in the additional 37 patients was 0.823 (95% CI = 0.685-0.905), indicating good agreement. CONCLUSION SWV values of CRLMs could provide prognostic information in patients with CRLMs treated with chemotherapy, as decreased SWV values on day 2 after chemotherapy was a significant predictive factor for better PFS.
Collapse
|
5
|
Deng H, Mi Y, Lu B, Xu P. Application of virtual touch tissue imaging quantification in diagnosis of supraspinatus tendon injury. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2021; 29:881-890. [PMID: 34120947 DOI: 10.3233/xst-210865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
OBJECTIVE To explore the value of virtual touch imaging and quantification (VTIQ) shear wave elastography (SWE) in diagnosis of supraspinatus tendon tear. METHODS Eighty patients with unilateral supraspinatus tendon tear underwent shoulder arthroscopy were prospective studied. Tendinopathy, partial-thickness tear or full-thickness tear of supraspinatus tendon were diagnosed according 2D ultrasound examination. Sensitivity, specificity and accuracy of ultrasonic diagnosis of supraspinatus tendon tear were calculated by arthroscopy as the gold standard. VTIQ was applied to measure the shear-wave velocity (SWV) of both normal and affected supraspinatus tendon. The differences of SWV in three types of supraspinatus tendon tear and receiver operating characteristic (ROC) curves were analyzed. RESULTS Among 80 patients, there were 20 tendinopathy, 31 partial tears and 29 full-thickness tears diagnosed by shoulder arthroscopy. Sensitivity, specificity and accuracy of 2D ultrasound in diagnosis of tendinopathy, partial tear and full-thickness tear groups were 78%, 90%and 83%; 71%, 86%and 73%; 86%, 88%and 88%, respectively. SWV of 80 supraspinatus tendon tears was 4.59±1.00 m/s, which was lower than that of normal supraspinatus tendon (4.59±1.00 m/s vs. 6.68±1.05 m/s, P < 0.01). SWV of supraspinatus tendon in tendinopathy, partial tear and full-thickness tear groups respectively were 5.66±0.97, 4.66±1.00, and 3.78±0.55 m/s, all lower than that of the contralateral normal supraspinatus tendon (all P < 0.05). In addition, the analysis of variance and pairwise comparison showed that SWV of supraspinatus tendon among three different degree of injury was statistically significant (all P < 0.001). The cutoff thresholds of SWV was 4.83 m/s to identify tendinopathy tear from partial tear and was 4.08 m/s to identify full-thickness tear from partial-thickness tear. CONCLUSION VTIQ SWE with SWV might identify degree of supraspinatus tendon tear and improve the value of ultrasonography, which should be further evaluated in large multicenter studies.
Collapse
Affiliation(s)
- Heping Deng
- Department of Ultrasonography, Hebei Medical Universitiy Third Affiliated Hospital, Shijiazhuang, Hebei, China
| | - Yaru Mi
- Department of Ultrasonography, Hebei Medical Universitiy Third Affiliated Hospital, Shijiazhuang, Hebei, China
| | - Bo Lu
- Department of Orthopaedics, Hebei Medical Universitiy Third Affiliated Hospital, Shijiazhuang, Hebei, China
| | - Ping Xu
- Department of Ultrasonography, Hebei Medical Universitiy Third Affiliated Hospital, Shijiazhuang, Hebei, China
| |
Collapse
|
6
|
Dietrich CF, Shi L, Wei Q, Dong Y, Cui XW, Löwe A, Worni M, Ferraioli G. What does liver elastography measure? Technical aspects and methodology. Minerva Gastroenterol (Torino) 2020; 67:129-140. [PMID: 33267564 DOI: 10.23736/s2724-5985.20.02787-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Elastography can be thought as an extension of the ancient technique of palpation. After giving a short introduction to the history of elastography, the different technologies that are nowadays available and the physics behind them, the article focuses on the assessment of liver stiffness in patients with diffuse liver disease using shear wave elastography (SWE). Practical advices on how to perform the SWE techniques and on the factors that should be considered for a correct interpretation of the results are given. This paper aimed to provide a practical guide for beginners and advanced clinical users to better understand technical aspects, methodologies and terminology.
Collapse
Affiliation(s)
- Christoph F Dietrich
- Department Allgemeine Innere Medizin (DAIM), Kliniken Beau Site, Salem und Permanence, Hirslanden, Bern, Switzerland -
| | - Long Shi
- Department of Ultrasound, Jingmen N. 2 People's Hospital, Jingmen, China
| | - Qi Wei
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yi Dong
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Axel Löwe
- Department Allgemeine Innere Medizin (DAIM), Kliniken Beau Site, Salem und Permanence, Hirslanden, Bern, Switzerland
| | - Mathias Worni
- Department of Visceral Surgery, Clarunis, University Center for Gastrointestinal and Liver Diseases, St. Clara University Hospital, Basel, Switzerland.,Swiss Institute for Translational and Entrepreneurial Medicine, Stiftung Lindenhof, Campus SLB, Bern, Switzerland.,Department of Surgery, Clinic Beau Site, Bern, Switzerland
| | - Giovanna Ferraioli
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia, Italy
| |
Collapse
|
7
|
Mack CL, Adams D, Assis DN, Kerkar N, Manns MP, Mayo MJ, Vierling JM, Alsawas M, Murad MH, Czaja AJ. Diagnosis and Management of Autoimmune Hepatitis in Adults and Children: 2019 Practice Guidance and Guidelines From the American Association for the Study of Liver Diseases. Hepatology 2020; 72:671-722. [PMID: 31863477 DOI: 10.1002/hep.31065] [Citation(s) in RCA: 412] [Impact Index Per Article: 103.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Accepted: 11/25/2019] [Indexed: 02/06/2023]
Affiliation(s)
- Cara L Mack
- Department of Pediatrics, University of Colorado School of Medicine, Aurora, CO
| | - David Adams
- Centre for Liver Research, University of Birmingham, Birmingham, UK
| | - David N Assis
- Department of Internal Medicine, Yale School of Medicine, New Haven, CT
| | - Nanda Kerkar
- Golisano Children's Hospital at Strong, University of Rochester Medical Center, New York, NY
| | - Michael P Manns
- Department of Gastroenterology, Hepatology and Endocrinology, Hannover Medical School, Hannover, Germany
| | - Marlyn J Mayo
- Division of Digestive and Liver Diseases, University of Texas SW Medical Center, Dallas, TX
| | - John M Vierling
- Medicine and Surgery, Baylor College of Medicine, Houston, TX
| | | | - Mohammad H Murad
- Mayo Knowledge and Encounter Research Unit, Mayo Clinic College of Medicine, Rochester, MN
| | - Albert J Czaja
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, MN
| |
Collapse
|
8
|
Fang C, Lim A, Sidhu PS. Ultrasound-based liver elastography in the assessment of fibrosis. Clin Radiol 2020; 75:822-831. [PMID: 32067699 DOI: 10.1016/j.crad.2020.01.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Accepted: 01/10/2020] [Indexed: 02/07/2023]
Abstract
Ultrasound-based elastography has rapidly replaced the need for liver biopsy in most patients with chronic liver disease in recent years. The technique is now widely supported by many manufacturers. This review will introduce various current ultrasound-based elastography techniques, review the physics and scanning techniques, discuss potential cofounding factors as well as summarising the evidence for its use in staging liver fibrosis using shear-wave elastography among different disease aetiologies. Future challenges and directions will be also be discussed.
Collapse
Affiliation(s)
- C Fang
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK.
| | - A Lim
- Department of Radiology, Imperial College Healthcare NHS Trust, London, UK
| | - P S Sidhu
- Department of Radiology, King's College Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
9
|
Luo H, Li T, Wu S, Zhu H, Chen K, Ma L, Lin M. Clinical value of virtual touch tissue imaging quantification in diagnosis and treatment of congenital muscular torticollis in children. Transl Pediatr 2020; 9:13-20. [PMID: 32154131 PMCID: PMC7036642 DOI: 10.21037/tp.2020.01.05] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND This study aimed to evaluate the clinical value of virtual touch tissue imaging quantification (VTIQ) in the diagnosis and treatment of congenital muscular torticollis (CMT) in children. METHODS Sixty-two CMT children treated in the clinics of our hospital were collected, and then 62 CMT children treated with manipulation massage were followed up; 23 CMT children receiving surgery in the same period served as controls. Conventional ultrasonography and VTIQ were performed at bilateral sternocleidomastoid muscles (SCM), and the shear wave velocity (SWV) was measured. RESULTS In 62 patients and 23 controls, the average SWV of affected SCM was higher than the contralateral SCM. The difference was statistically significant (P<0.01). There was no marked difference in the SWV of between the affected SCM and healthy SCM after massage (P>0.05). The SWV of SCM after treatment was lower than before treatment. The difference was statistically significant (P<0.01). The SWV of affected SCM in 23 controls was higher than the affected SCM in 62 patients before massage. The difference was statistically significant (P<0.01). CONCLUSIONS VTIQ is helpful for the diagnosis of CMT in children and can also be employed for the monitoring of therapeutic effect.
Collapse
Affiliation(s)
- Hongxia Luo
- Department of Ultrasound, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, China
| | - Tianran Li
- Department of Ultrasound, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, China
| | - Senmin Wu
- Department of Ultrasound, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, China
| | - Hui Zhu
- Department of Ultrasound, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, China
| | - Kai Chen
- Department of Ultrasound, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, China
| | - Lie Ma
- Department of Ultrasound, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, China
| | - Miaomiao Lin
- Department of Pediatrics, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, China
| |
Collapse
|
10
|
Durot I, Akhbardeh A, Rosenberg J, Willmann JK. Point Shear Wave Elastography for Grading Liver Fibrosis: Can the Number of Measurements Be Reduced? ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2569-2577. [PMID: 30224172 DOI: 10.1016/j.ultrasmedbio.2018.07.028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 07/19/2018] [Accepted: 07/28/2018] [Indexed: 06/08/2023]
Abstract
The aim of this study was to assess whether the number of liver point shear wave elastography (pSWE) measurements could be reduced compared with the currently recommended 10 valid measurements. Three thousand four hundred one pSWE examinations in patients with liver disease were performed with 10 consecutive valid measurements in liver segment 8. Liver fibrosis grading using published cutoff values were compared retrospectively using the median of 10 versus the first 1-9 measurements with Kendall's τ coefficient. Overall and binary (clinically significant [≥F2] versus non-significant [F0/F1]) fibrosis grading highly correlated when using 5-9 versus 10 valid measurements (τ = 0.96/0.95, p < 0.001). With the use of 5 valid measurements, a change in binary grading was observed in 87 of 3401 (2.6%) exams and only when velocities measured between 1.1 and 1.5 m/s. Therefore, using 5-9 valid measurements in pSWE of the liver results in a small portion of liver fibrosis grading misclassifications compared with use of 10 measurements and could help decrease scanning time, cost and discomfort in sonographers and patients.
Collapse
Affiliation(s)
- Isabelle Durot
- Department of Radiology, School of Medicine, Stanford University, Stanford, California, USA.
| | - Alireza Akhbardeh
- Department of Radiology, School of Medicine, Stanford University, Stanford, California, USA
| | - Jarrett Rosenberg
- Department of Radiology, School of Medicine, Stanford University, Stanford, California, USA
| | - Jürgen K Willmann
- Department of Radiology, School of Medicine, Stanford University, Stanford, California, USA
| |
Collapse
|
11
|
Noninvasive Assessment of Portal Hypertension in Advanced Chronic Liver Disease: An Update. Gastroenterol Res Pract 2018; 2018:4202091. [PMID: 29977287 PMCID: PMC6011072 DOI: 10.1155/2018/4202091] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Accepted: 04/30/2018] [Indexed: 12/14/2022] Open
Abstract
The assessment of portal hypertension is a relevant step in the evaluation of newly diagnosed advanced chronic liver disease (ACLD). The current gold standard includes the invasive evaluation of hepatic venous pressure gradient (HVPG) and endoscopy. However, noninvasive or minimally invasive techniques to assess portal hypertension have been proposed and well established. In the present manuscript, we review clinical studies on the use of noninvasive or minimally invasive techniques to assess portal hypertension in ACLD patients.
Collapse
|
12
|
Fang C, Jaffer OS, Yusuf GT, Konstantatou E, Quinlan DJ, Agarwal K, Quaglia A, Sidhu PS. Reducing the Number of Measurements in Liver Point Shear-Wave Elastography: Factors that Influence the Number and Reliability of Measurements in Assessment of Liver Fibrosis in Clinical Practice. Radiology 2018. [DOI: 10.1148/radiol.2018172104] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Cheng Fang
- From the Department of Radiology (C.F., O.S.J., G.T.Y., E.K., D.J.Q., P.S.S.) and Institute of Liver Studies (K.A., A.Q.), King’s College Hospital, Denmark Hill, London, SE5 9RS, England
| | - Ounali S. Jaffer
- From the Department of Radiology (C.F., O.S.J., G.T.Y., E.K., D.J.Q., P.S.S.) and Institute of Liver Studies (K.A., A.Q.), King’s College Hospital, Denmark Hill, London, SE5 9RS, England
| | - Gibran T. Yusuf
- From the Department of Radiology (C.F., O.S.J., G.T.Y., E.K., D.J.Q., P.S.S.) and Institute of Liver Studies (K.A., A.Q.), King’s College Hospital, Denmark Hill, London, SE5 9RS, England
| | - Eleni Konstantatou
- From the Department of Radiology (C.F., O.S.J., G.T.Y., E.K., D.J.Q., P.S.S.) and Institute of Liver Studies (K.A., A.Q.), King’s College Hospital, Denmark Hill, London, SE5 9RS, England
| | - Daniel J. Quinlan
- From the Department of Radiology (C.F., O.S.J., G.T.Y., E.K., D.J.Q., P.S.S.) and Institute of Liver Studies (K.A., A.Q.), King’s College Hospital, Denmark Hill, London, SE5 9RS, England
| | - Kosh Agarwal
- From the Department of Radiology (C.F., O.S.J., G.T.Y., E.K., D.J.Q., P.S.S.) and Institute of Liver Studies (K.A., A.Q.), King’s College Hospital, Denmark Hill, London, SE5 9RS, England
| | - Alberto Quaglia
- From the Department of Radiology (C.F., O.S.J., G.T.Y., E.K., D.J.Q., P.S.S.) and Institute of Liver Studies (K.A., A.Q.), King’s College Hospital, Denmark Hill, London, SE5 9RS, England
| | - Paul S. Sidhu
- From the Department of Radiology (C.F., O.S.J., G.T.Y., E.K., D.J.Q., P.S.S.) and Institute of Liver Studies (K.A., A.Q.), King’s College Hospital, Denmark Hill, London, SE5 9RS, England
| |
Collapse
|
13
|
Berná-Serna JD, Sánchez-Jiménez R, Velázquez-Marín F, Sainz de Baranda P, Guzmán-Aroca F, Fernández-Hernández C, Doménech-Abellán E, Abellán-Rivero D, Ruiz-Merino G, Madrid-Conesa J, Canteras-Jordana M. Acoustic radiation force impulse imaging for detection of liver fibrosis in overweight and obese children. Acta Radiol 2018; 59:247-253. [PMID: 28475023 DOI: 10.1177/0284185117707359] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Background Acoustic radiation force impulse (ARFI) is a non-invasive alternative to a liver biopsy for the evaluation of liver fibrosis (LF). Purpose To investigate the potential usefulness of acoustic radiation force impulse ARFI for detecting LF in overweight and obese children Material and Methods A cross-sectional study was conducted in 148 schoolchildren. A diagnosis of non-alcoholic fatty liver disease (NAFLD) and LF was based on ultrasound (US) and ARFI shear wave velocity (SWV). Results The laboratory parameters were normal in all the children. NAFLD was observed in 50 children (33.8%). The median SWV was 1.18 ± 0.28 m/s. Differences between ARFI categories and hepatic steatosis grades were observed (χ2 = 43.38, P = 0.0005). No fibrosis or insignificant fibrosis (SWV ≤ 1.60 m/s) was detected in 137 children (92.5%), and significant fibrosis (SWV > 1.60 m/s) in 11 children (7.5%), nine of whom had normal US or mild steatosis. Conclusion The present study is the first to evaluate the utility of the ARFI technique for detecting LF in overweight and obese children. The results of the study suggest that children with normal laboratory parameters such as normal liver ultrasound or mild steatosis may present with significant LF.
Collapse
Affiliation(s)
- Juan D Berná-Serna
- Department of Radiology, Virgen de la Arrixaca University Clinical Hospital- IMIB, Ctra. Madrid-Cartagena, 30120, El Palmar (Murcia), Spain
| | - Regina Sánchez-Jiménez
- Department of Radiology, Virgen de la Arrixaca University Clinical Hospital- IMIB, Ctra. Madrid-Cartagena, 30120, El Palmar (Murcia), Spain
| | - Francisca Velázquez-Marín
- Department of Radiology, Virgen de la Arrixaca University Clinical Hospital- IMIB, Ctra. Madrid-Cartagena, 30120, El Palmar (Murcia), Spain
| | | | - Florentina Guzmán-Aroca
- Department of Radiology, Virgen de la Arrixaca University Clinical Hospital- IMIB, Ctra. Madrid-Cartagena, 30120, El Palmar (Murcia), Spain
| | - Carmen Fernández-Hernández
- Department of Radiology, Virgen de la Arrixaca University Clinical Hospital- IMIB, Ctra. Madrid-Cartagena, 30120, El Palmar (Murcia), Spain
| | - Ernesto Doménech-Abellán
- Department of Radiology, Virgen de la Arrixaca University Clinical Hospital- IMIB, Ctra. Madrid-Cartagena, 30120, El Palmar (Murcia), Spain
| | - Dolores Abellán-Rivero
- Department of Radiology, Virgen de la Arrixaca University Clinical Hospital- IMIB, Ctra. Madrid-Cartagena, 30120, El Palmar (Murcia), Spain
| | | | - Juan Madrid-Conesa
- Department of Endocrinology and Nutrition, Virgen de la Arrixaca University Clinical Hospital, Murcia, Spain
| | | |
Collapse
|
14
|
Interpretation US Elastography in Chronic Hepatitis B with or without Anti-HBV Therapy. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7111164] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
15
|
Fang C, Konstantatou E, Romanos O, Yusuf GT, Quinlan DJ, Sidhu PS. Reproducibility of 2-Dimensional Shear Wave Elastography Assessment of the Liver: A Direct Comparison With Point Shear Wave Elastography in Healthy Volunteers. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2017; 36:1563-1569. [PMID: 28370146 DOI: 10.7863/ultra.16.07018] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2016] [Accepted: 10/14/2016] [Indexed: 06/07/2023]
Abstract
OBJECTIVES Two-dimensional shear wave elastography (2D-SWE) imaging for the noninvasive assessment of tissue stiffness was assessed for reproducibility in healthy volunteers in quantifying liver elasticity, compared with an established point shear wave elastography (p-SWE) technique also known as virtual touch quantification (VTQ) (SIEMENS). METHODS Eleven healthy volunteers were examined by four experienced operators on two occasions, separated by two weeks (sessions A and B). Ten 2D-SWE using LOGIQ E9 and p-SWE measurements using VTQ (in meters per second) were consecutively taken from deep portions of liver segments 5 or 6 away from vascular structures, using standard techniques. Inter- and intra-observer agreement was assessed by intraclass coefficient (ICC). RESULTS A total of 880 2D-SWE and p-SWE velocities were recorded. Mean values from the four operators ranged between 1.188 and 1.196 m/s for 2D-SWE and 1.170 to 1.207 m/s for p-SWE. Interobserver reproducibility was good for both sessions with ICCs of 0.88 and 0.93 (2D-SWE) and 0.87 and 0.93 (p-SWE). The overall intra-operator reproducibility between sessions A and B was good for both p-SWE and 2D-SWE with ICC of 0.87 and 0.83, respectively. For inter- and intra-observer variability, the ICC was more than or equal to 0.71, indicating that the results were reliable. There was a strong and significant correlation between the 2D-SWE and p-SWE measurements (r = 0.87, P = .0006), but their velocities did not agree equally across different velocities. CONCLUSIONS Two-dimensional SWE using LOGIQ E9 is a reliable and reproducible method for measuring elasticity in healthy volunteers and has a similar degree of reliability as p-SWE using VTQ, but absolute measurements from the two techniques should not be used interchangeably.
Collapse
Affiliation(s)
- Cheng Fang
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Eleni Konstantatou
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Odyssefs Romanos
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Gibran T Yusuf
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Daniel J Quinlan
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Paul S Sidhu
- Department of Radiology, King's College Hospital, London, United Kingdom
| |
Collapse
|
16
|
Piscaglia F, Salvatore V, Mulazzani L, Cantisani V, Colecchia A, Di Donato R, Felicani C, Ferrarini A, Gamal N, Grasso V, Marasco G, Mazzotta E, Ravaioli F, Ruggieri G, Serio I, Sitouok Nkamgho JF, Serra C, Festi D, Schiavone C, Bolondi L. Differences in liver stiffness values obtained with new ultrasound elastography machines and Fibroscan: A comparative study. Dig Liver Dis 2017; 49:802-808. [PMID: 28365330 DOI: 10.1016/j.dld.2017.03.001] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Revised: 02/17/2017] [Accepted: 03/02/2017] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Whether Fibroscan thresholds can be immediately adopted for none, some or all other shear wave elastography techniques has not been tested. The aim of the present study was to test the concordance of the findings obtained from 7 of the most recent ultrasound elastography machines with respect to Fibroscan. METHODS Sixteen hepatitis C virus-related patients with fibrosis ≥2 and having reliable results at Fibroscan were investigated in two intercostal spaces using 7 different elastography machines. Coefficients of both precision (an index of data dispersion) and accuracy (an index of bias correction factors expressing different magnitudes of changes in comparison to the reference) were calculated. RESULTS Median stiffness values differed among the different machines as did coefficients of both precision (range 0.54-0.72) and accuracy (range 0.28-0.87). When the average of the measurements of two intercostal spaces was considered, coefficients of precision significantly increased with all machines (range 0.72-0.90) whereas of accuracy improved more scatteredly and by a smaller degree (range 0.40-0.99). CONCLUSIONS The present results showed only moderate concordance of the majority of elastography machines with the Fibroscan results, preventing the possibility of the immediate universal adoption of Fibroscan thresholds for defining liver fibrosis staging for all new machines.
Collapse
Affiliation(s)
- Fabio Piscaglia
- Department of Medical and Surgical Sciences, University of Bologna, Italy.
| | - Veronica Salvatore
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Lorenzo Mulazzani
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Vito Cantisani
- Department of Radiological Sciences, Policlinico Umberto I, University La Sapienza, Rome, Italy
| | - Antonio Colecchia
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Roberto Di Donato
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Cristina Felicani
- Unit of Internal Medicine and Organ Insufficiency, S. Orsola-Malpighi Hospital, Bologna, Italy
| | - Alessia Ferrarini
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Nesrine Gamal
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Valentina Grasso
- Unit of Internal Medicine and Organ Insufficiency, S. Orsola-Malpighi Hospital, Bologna, Italy
| | - Giovanni Marasco
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Elena Mazzotta
- Unit of Internal Medicine and Organ Insufficiency, S. Orsola-Malpighi Hospital, Bologna, Italy
| | - Federico Ravaioli
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Giacomo Ruggieri
- Division of Infectious Disease, G. d'Annunzio University, Chieti, Italy
| | - Ilaria Serio
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | | | - Carla Serra
- Unit of Internal Medicine and Organ Insufficiency, S. Orsola-Malpighi Hospital, Bologna, Italy
| | - Davide Festi
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| | - Cosima Schiavone
- Unit of Internistic Ultrasound, Department of Medicine and Science of Aging, G. d'Annunzio University, Chieti, Italy
| | - Luigi Bolondi
- Department of Medical and Surgical Sciences, University of Bologna, Italy
| |
Collapse
|
17
|
Lodwick D, Dienhart M, Cooper JN, Fung B, Lopez J, Smith S, Warren P, Balint J, Minneci PC. A pilot study of ultrasound elastography as a non-invasive method to monitor liver disease in children with short bowel syndrome. J Pediatr Surg 2017; 52:962-965. [PMID: 28343660 DOI: 10.1016/j.jpedsurg.2017.03.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Accepted: 03/09/2017] [Indexed: 12/12/2022]
Abstract
BACKGROUND Our objective was to evaluate the accuracy of acoustic radiation force impulse (ARFI) elastography in determining extent of liver fibrosis in pediatric patients with short bowel syndrome (SBS). METHODS This prospective cohort study included pediatric patients with SBS who underwent ultrasound with ARFI measurements of shear wave speed (SWS) and liver biopsy within 30days of each other between 12/2014-9/2015. The mean and median SWS were compared to the stage of fibrosis. Receiver operating characteristic curves (ROC) were also generated to assess the classification accuracy of SWS measurements for mild (F0-F1) versus moderate/severe fibrosis (F2-F4). RESULTS Twelve patients were included with median age 1.4years and median weight 11.3kg. The median direct bilirubin level was 0.3mg/dL at the time of biopsy. On liver biopsy, 6 patients had mild fibrosis (F1), 3 had septal fibrosis (F3), and 3 had cirrhosis (F4). The area under the ROC curve for elastography to differentiate moderate/severe liver fibrosis from mild disease was 0.83 (95CI 0.58-1.00) and 0.86 (95CI 0.63-1.00) for the median SWS and mean SWS, respectively. CONCLUSIONS These early results suggest that ARFI ultrasound elastography may be a reliable non-invasive method to monitor liver fibrosis in pediatric patients with SBS. TYPE OF STUDY Prospective observational cohort. LEVEL OF EVIDENCE 3.
Collapse
Affiliation(s)
- Daniel Lodwick
- Center for Surgical Outcomes Research, The Research Institute at Nationwide Children's Hospital, Columbus, OH; Department of Surgery, Nationwide Children's Hospital, The Ohio State University College of Medicine, Columbus, OH
| | - Molly Dienhart
- Department of Gastroenterology, Nationwide Children's Hospital, Columbus, OH
| | - Jennifer N Cooper
- Center for Surgical Outcomes Research, The Research Institute at Nationwide Children's Hospital, Columbus, OH
| | - Bonita Fung
- Department of Pathology, Nationwide Children's Hospital, Columbus, OH
| | - Joseph Lopez
- Center for Surgical Outcomes Research, The Research Institute at Nationwide Children's Hospital, Columbus, OH; Department of Gastroenterology, Nationwide Children's Hospital, Columbus, OH
| | - Sally Smith
- Department of Radiology, Nationwide Children's Hospital, Columbus, OH
| | - Patrick Warren
- Department of Radiology, Nationwide Children's Hospital, Columbus, OH
| | - Jane Balint
- Department of Gastroenterology, Nationwide Children's Hospital, Columbus, OH
| | - Peter C Minneci
- Center for Surgical Outcomes Research, The Research Institute at Nationwide Children's Hospital, Columbus, OH; Department of Surgery, Nationwide Children's Hospital, The Ohio State University College of Medicine, Columbus, OH.
| |
Collapse
|
18
|
Knop V, Hoppe D, Welzel T, Vermehren J, Herrmann E, Vermehren A, Friedrich-Rust M, Sarrazin C, Zeuzem S, Welker MW. Regression of fibrosis and portal hypertension in HCV-associated cirrhosis and sustained virologic response after interferon-free antiviral therapy. J Viral Hepat 2016; 23:994-1002. [PMID: 27500382 DOI: 10.1111/jvh.12578] [Citation(s) in RCA: 118] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Accepted: 07/07/2016] [Indexed: 02/06/2023]
Abstract
It is still controversial, whether and to what amount cirrhosis and portal hypertension are reversible in patients with hepatitis C virus (HCV)-associated cirrhosis and sustained virologic response (SVR) after interferon-free antiviral therapy. In this study, we prospectively evaluated dynamics of liver and spleen stiffness in HCV-infected patients with advanced liver disease and SVR after interferon-free treatment. A total of 54 patients with HCV-associated cirrhosis and SVR were included. Liver and spleen stiffness was measured at therapy baseline (BL), end of treatment (EOT) and 24 weeks after EOT (FU24) by transient liver elastography (L-TE) as well as by acoustic radiation force impulse of the liver (L-ARFI) and spleen (S-ARFI), as well as biochemical, virologic and clinical data. Improvement of liver and spleen stiffness was found in 44 of 50 (88%), 31 of 54 (57%) and 25 of 54 (46%) of patients assessed by L-TE, L-ARFI and S-ARFI between baseline and FU24. Liver stiffness assessed by L-TE improved between BL [median (range), 32.5 (9.1-75) kPa] and EOT [median (range), 21.3 (6.7-73.5) kPa; (P<.0001)], and between BL and FU24 [median (range), 21.2 (5.4-70) kPa; (P<.0001)]. Liver stiffness assessed by L-ARFI improved between BL [median (range), 2.7 (1.2-4.1) m/s] and FU24 [median (range), 2.4 (1.2-3.9) m/s; P=.002), while spleen stiffness remained unchanged. Our data suggest that improvement of liver stiffness may be rather due to reduced necroinflammation and may be due to a less extent to regression of cirrhosis, as dynamics of liver stiffness improvement was more pronounced between BL and EOT than BL and FU24.
Collapse
Affiliation(s)
- V Knop
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - D Hoppe
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - T Welzel
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - J Vermehren
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - E Herrmann
- Institut für Biostatistik und mathematische Modellierung, Goethe-Universität Frankfurt, Frankfurt am Main, Germany
| | - A Vermehren
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - M Friedrich-Rust
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - C Sarrazin
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - S Zeuzem
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - M-W Welker
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| |
Collapse
|
19
|
Giunta M, Conte D, Fraquelli M. Role of spleen elastography in patients with chronic liver diseases. World J Gastroenterol 2016; 22:7857-7867. [PMID: 27672283 PMCID: PMC5028802 DOI: 10.3748/wjg.v22.i35.7857] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 08/16/2016] [Accepted: 08/30/2016] [Indexed: 02/06/2023] Open
Abstract
The development of liver cirrhosis and portal hypertension (PH), one of its major complications, are structural and functional alterations of the liver, occurring in many patients with chronic liver diseases (CLD). Actually the progressive deposition of hepatic fibrosis has a key role in the prognosis of CLD patients. The subsequent development of PH leads to its major complications, such as ascites, hepatic encephalopathy, variceal bleeding and decompensation. Liver biopsy is still considered the reference standard for the assessment of hepatic fibrosis, whereas the measurement of hepatic vein pressure gradient is the standard to ascertain the presence of PH and upper endoscopy is the method of choice to detect the presence of oesophageal varices. However, several non-invasive tests, including elastographic techniques, are currently used to evaluate the severity of liver disease and predict its prognosis. More recently, the measurement of the spleen stiffness has become particularly attractive to assess, considering the relevant role accomplished by the spleen in splanchnic circulation in the course of liver cirrhosis and in the PH. Moreover, spleen stiffness as compared with liver stiffness better represents the dynamic changes occurring in the advanced stages of cirrhosis and shows higher diagnostic performance in detecting esophageal varices. The aim of this review is to provide an exhaustive overview of the actual role of spleen stiffness measurement as assessed by several elastographic techniques in evaluating both liver disease severity and the development of cirrhosis complications, such as PH and to highlight its potential and possible limitations.
Collapse
|
20
|
Can acoustic radiation force impulse elastography be a substitute for liver biopsy in predicting liver fibrosis? Clin Radiol 2016; 71:869-75. [DOI: 10.1016/j.crad.2016.04.015] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2015] [Revised: 02/18/2016] [Accepted: 04/08/2016] [Indexed: 02/08/2023]
|
21
|
Effect of liposomal local therapy on salivary glands in acoustic radiation force impulse imaging in Sjögren's syndrome. Clin Rheumatol 2016; 35:2597-601. [PMID: 27572326 DOI: 10.1007/s10067-016-3395-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2016] [Revised: 08/20/2016] [Accepted: 08/22/2016] [Indexed: 12/15/2022]
Abstract
The purpose of this study was to evaluate the utility of acoustic radiation force impulse (ARFI) imaging as a monitoring tool for the effect of a liposomal local therapy in patients with dry mouth symptoms due to primary Sjögren's syndrome (pSS). Fifty patients with pSS, diagnosed according to the American-European Consensus Group (AECG) criteria, were included. Clinical data were collected, and sonographic examination including ARFI imaging of the parotid and submandibular glands was performed. Subjective symptoms were evaluated via visual analogue scales (VAS), and the unstimulated whole salivary flow was measured. After a two-month period of liposomal local therapy, sonographic examination was repeated and both subjective and objective symptoms were re-evaluated. Before local treatment, the mean ARFI value of parotid glands was 2.96 m/s (SD 0.97). Mean ARFI value of the submandibular glands was 2.09 m/s (SD 0.71). After the two-month treatment period, a significant decline of ARFI values in the parotid glands to a value of 2.34 m/s (SD 0.70, p < 0.001) could be observed. The submandibular glands did not show any significant change. Further, a significant reduction of the subjective sensation of dry mouth symptoms could be observed (p = 0.0001). With the application of ARFI imaging, a decline in parotid gland stiffness could be observed in patients with primary Sjögren's Syndrome accompanied by a significant improvement of the subjective sensation of dry mouth symptoms. The seromucous submandibular glands did not show any changes compared to the serous parotid glands.
Collapse
|
22
|
Bruno C, Minniti S, Bucci A, Pozzi Mucelli R. ARFI: from basic principles to clinical applications in diffuse chronic disease-a review. Insights Imaging 2016; 7:735-46. [PMID: 27553006 PMCID: PMC5028343 DOI: 10.1007/s13244-016-0514-5] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 07/05/2016] [Accepted: 07/19/2016] [Indexed: 12/11/2022] Open
Abstract
Abstract The many factors influencing the shear wave velocity (SWV) measured with Acoustic Radiation Force Impulse (ARFI) are examined in order to define the most correct examination technique. In particular, attention is given to the information achieved by experimental models, such as phantoms and animal studies. This review targets the clinical applications of ARFI in the evaluation of chronic diffuse disease, especially of liver and kidneys. The contribution of ARFI to the clinical workout of these patients and some possible perspectives are described. Teaching Points • Stiffness significantly varies among normal and abnormal biological tissues. • In clinical applications physical, geometrical, anatomical and physiological factors influence the SWV. • Elastographic techniques can quantify fibrosis, which is directly related to stiffness. • ARFI can be useful in chronic diffuse disease of liver and kidney.
Collapse
Affiliation(s)
- Costanza Bruno
- Department of Radiology, Verona University, P.le LA Scuro 10, 37134, Verona, Italy.
| | | | - Alessandra Bucci
- Department of Radiology, Verona University, P.le LA Scuro 10, 37134, Verona, Italy
| | | |
Collapse
|
23
|
Chin JL, Pavlides M, Moolla A, Ryan JD. Non-invasive Markers of Liver Fibrosis: Adjuncts or Alternatives to Liver Biopsy? Front Pharmacol 2016; 7:159. [PMID: 27378924 PMCID: PMC4913110 DOI: 10.3389/fphar.2016.00159] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 05/31/2016] [Indexed: 12/13/2022] Open
Abstract
Liver fibrosis reflects sustained liver injury often from multiple, simultaneous factors. Whilst the presence of mild fibrosis on biopsy can be a reassuring finding, the identification of advanced fibrosis is critical to the management of patients with chronic liver disease. This necessity has lead to a reliance on liver biopsy which itself is an imperfect test and poorly accepted by patients. The development of robust tools to non-invasively assess liver fibrosis has dramatically enhanced clinical decision making in patients with chronic liver disease, allowing a rapid and informed judgment of disease stage and prognosis. Should a liver biopsy be required, the appropriateness is clearer and the diagnostic yield is greater with the use of these adjuncts. While a number of non-invasive liver fibrosis markers are now used in routine practice, a steady stream of innovative approaches exists. With improvement in the reliability, reproducibility and feasibility of these markers, their potential role in disease management is increasing. Moreover, their adoption into clinical trials as outcome measures reflects their validity and dynamic nature. This review will summarize and appraise the current and novel non-invasive markers of liver fibrosis, both blood and imaging based, and look at their prospective application in everyday clinical care.
Collapse
Affiliation(s)
- Jun L Chin
- School of Medicine and Medical Science, University College Dublin Dublin, Ireland
| | - Michael Pavlides
- Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford Oxford, UK
| | - Ahmad Moolla
- Radcliffe Department of Medicine, University of Oxford Oxford, UK
| | - John D Ryan
- Translational Gastroenterology Unit, University of Oxford Oxford, UK
| |
Collapse
|
24
|
Dong CF, Xiao J, Shan LB, Li HY, Xiong YJ, Yang GL, Liu J, Yao SM, Li SX, Le XH, Yuan J, Zhou BP, Tipoe GL, Liu YX. Combined acoustic radiation force impulse, aminotransferase to platelet ratio index and Forns index assessment for hepatic fibrosis grading in hepatitis B. World J Hepatol 2016; 8:616-624. [PMID: 27190578 PMCID: PMC4867419 DOI: 10.4254/wjh.v8.i14.616] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 03/08/2016] [Accepted: 04/22/2016] [Indexed: 02/06/2023] Open
Abstract
AIM: To investigate the combined diagnostic accuracy of acoustic radiation force impulse (ARFI), aspartate aminotransferase to platelet ratio index (APRI) and Forns index for a non-invasive assessment of liver fibrosis in patients with chronic hepatitis B (CHB).
METHODS: In this prospective study, 206 patients had CHB with liver fibrosis stages F0-F4 classified by METAVIR and 40 were healthy volunteers were measured by ARFI, APRI and Forns index separately or combined as indicated.
RESULTS: ARFI, APRI or Forns index demonstrated a significant correlation with the histological stage (all P < 0.001). According to the AUROC of ARFI and APRI for evaluating fibrotic stages more than F2, ARFI showed an enhanced diagnostic accuracy than APRI (P < 0.05). The combined measurement of ARFI and APRI exhibited better accuracy than ARFI alone when evaluating ≥ F2 fibrotic stage (Z = 2.77, P = 0.006). Combination of ARFI, APRI and Forns index did not obviously improve the diagnostic accuracy compared to the combination of ARFI and APRI (Z = 0.958, P = 0.338).
CONCLUSION: ARFI + APRI showed enhanced diagnostic accuracy than ARFI or APRI alone for significant liver fibrosis and ARFI + APRI + Forns index shows the same effect with ARFI + APRI.
Collapse
|
25
|
Deng Y, Rouze NC, Palmeri ML, Nightingale KR. On System-Dependent Sources of Uncertainty and Bias in Ultrasonic Quantitative Shear-Wave Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:381-93. [PMID: 26886980 PMCID: PMC4821786 DOI: 10.1109/tuffc.2016.2524260] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Ultrasonic quantitative shear-wave imaging methods have been developed over the last decade to estimate tissue elasticity by measuring the speed of propagating shear waves following acoustic radiation force excitation. This work discusses eight sources of uncertainty and bias arising from ultrasound system-dependent parameters in ultrasound shear-wave speed (SWS) measurements. Each of the eight sources of error is discussed in the context of a linear, isotropic, elastic, homogeneous medium, combining previously reported analyses with Field II simulations, full-wave 2-D acoustic propagation simulations, and experimental studies. Errors arising from both spatial and temporal sources lead to errors in SWS measurements. Arrival time estimation noise, speckle bias, hardware fluctuations, and phase aberration cause uncertainties (variance) in SWS measurements, while pulse repetition frequency (PRF) and beamforming errors, as well as coupling medium sound speed mismatch, cause biases in SWS measurements (accuracy errors). Calibration of the sources of bias is an important step in the development of shear-wave imaging systems. In a well-calibrated system, where the sources of bias are minimized, and averaging over a region of interest (ROI) is employed to reduce the sources of uncertainty, an SWS error can be expected.
Collapse
|
26
|
Di Vece F, Tombesi P, Ermili F, Sartori S. Management of incidental renal masses: Time to consider contrast-enhanced ultrasonography. ULTRASOUND (LEEDS, ENGLAND) 2016; 24:34-40. [PMID: 27433273 PMCID: PMC4760605 DOI: 10.1177/1742271x15626194] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Accepted: 12/15/2015] [Indexed: 12/21/2022]
Abstract
Proliferation of imaging studies for different clinical purposes and continuous improvement of imaging technology have led to an increasing number of incidental findings of renal masses. It is estimated that over 50% of patients older than 50 years have at least one renal mass. The majority of incidental renal masses are simple cysts that can be easily diagnosed by conventional ultrasonography. However, some incidental renal masses are not simple cysts, and differentiation between benign and malignant entities requires further imaging modalities. In the past, multiphase contrast-enhanced computed tomography and magnetic resonance imaging were considered the primary imaging modalities used to characterize and stage complex cystic and solid renal lesions. Currently, contrast-enhanced ultrasonography represents a novel alternative to contrast-enhanced computed tomography and magnetic resonance imaging. Contrast-enhanced ultrasonography employs microbubble contrast agents that allow the study of different enhancement phases of the kidney without risk of nephrotoxicity and radiation exposure. The diagnostic accuracy of contrast-enhanced ultrasonography in the characterization of complex renal cysts is comparable to that of computed tomography and magnetic resonance imaging, and several studies have demonstrated its reliability also in identifying solid lesions such as pseudotumors, typical angiomyolipomas, and clear cell renal carcinomas. Considering the high incidence of incidental renal masses and the need for rapid and reliable diagnosis, contrast-enhanced ultrasonography could be proposed as the first step in the diagnostic work-up of renal masses because of its safety and cost effectiveness. In this paper, we propose a diagnostic algorithm for the characterization of cystic and solid renal masses.
Collapse
Affiliation(s)
- Francesca Di Vece
- Section of Interventional Ultrasound, Medical Department, St. Anna Hospital, Italy
| | - Paola Tombesi
- Section of Interventional Ultrasound, Medical Department, St. Anna Hospital, Italy
| | - Francesca Ermili
- Section of Interventional Ultrasound, Medical Department, St. Anna Hospital, Italy
| | - Sergio Sartori
- Section of Interventional Ultrasound, Medical Department, St. Anna Hospital, Italy
| |
Collapse
|
27
|
Cabassa P, Ravanelli M, Rossini A, Contessi G, Almajdalawi R, Maroldi R. Acoustic radiation force impulse quantification of spleen elasticity for assessing liver fibrosis. ACTA ACUST UNITED AC 2015; 40:738-44. [PMID: 25425490 DOI: 10.1007/s00261-014-0306-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
PURPOSE The purpose of this study is to assess the correlation between liver fibrosis and spleen stiffness measured by ARFI in patients with chronic viral hepatitis (B or C) and to explore the possible complementary role of spleen and liver ARFI in grading liver fibrosis. METHODS 84 subjects (51 patients, 33 healthy volunteers) were enrolled. ARFI of the spleen and the liver was performed. Patients subsequently underwent liver biopsy for grading liver fibrosis according to Knodell scoring system. Multivariate logistic regression and decision tree analysis were adopted to test the relationship between spleen and liver stiffness (independent variables) and liver fibrosis (F1< vs. ≥F3). Leave-One-Out Cross-Validation was used for validating the predictive classification models. Area under the ROC curve (AUROCC) was used as accuracy metric. RESULTS Spleen ARFI was able to discriminate early (F1) from severe (≥F3) liver fibrosis with an optimal cut-off of 3.05 m/s: AUROCC 0.807, cross-validated AUROCC 0.614. Liver ARFI was superior to spleen ARFI, using a cut-off of 2.11 m/s: AUROCC 0.879, cross-validated AUROCC 0.672. Neither spleen nor liver ARFI was able to differentiate healthy volunteers from F1 patients. Odds ratios derived from logistic regression were 23.1 and 9.9 for liver and spleen ARFI, respectively; resulting AUROCC was 0.905 (cross-validated 0.848). A decision tree considering the sequential use of liver and spleen ARFI with cut-off of 2.14 and 3.39 m/s, respectively, resulted in AUROCC of 0.903 (cross-validated 0.7). CONCLUSIONS Spleen ARFI has the potential to discriminate early from severe liver fibrosis. Spleen and liver ARFI, when combined, show a better discriminative power than liver ARFI alone.
Collapse
Affiliation(s)
- Paolo Cabassa
- Department of Radiology, University of Brescia, Piazzale Spedali Civili 1, 25123, Brescia, Italy,
| | | | | | | | | | | |
Collapse
|
28
|
D'Onofrio M, De Robertis R, Crosara S, Poli C, Canestrini S, Demozzi E, Pozzi Mucelli R. Acoustic radiation force impulse with shear wave speed quantification of pancreatic masses: A prospective study. Pancreatology 2015; 16:106-9. [PMID: 26746355 DOI: 10.1016/j.pan.2015.12.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Revised: 10/14/2015] [Accepted: 12/04/2015] [Indexed: 12/11/2022]
Abstract
BACKGROUND Acoustic Radiation Force Impulse (ARFI) is a new ultrasound technique that evaluates mechanical properties of tissues. To evaluate the use of ARFI with shear waves speed quantification for pancreatic masses characterization during the ultrasound examination. METHODS 123 pancreatic lesions were prospectively evaluated. Median shear waves speeds were compared with Mann-Whitney U test. Two reading methods were applied for the characterization of adenocarcinoma: more than one measurement above the top shear waves speed (SWS) value. Two reading methods were applied to diagnose mucinous lesion: at least 2 (method 1) or 3 (method 2) numerical measurements. Sensitivity, specificity, positive and negative predictive values and accuracy of each reading method were calculated. Forty volunteers were included for normal ARFI values. RESULTS In the adenocarcinoma group median SWS value was 2.74 m/s. In the volunteers group the median SWS value was 1.17 m/s. Significant difference between SWS median values of adenocarcinoma and normal pancreas was found (P < 0.05). For the diagnosis of pancreatic solid masses if more than one measurement is above the top SWS value of 4.00 m/s results in the study, the diagnosis of ductal adenocarcinoma is highly specific with specificity and PPV of 100%. Good sensitivity (73.3%) and specificity (83.3%) were obtained for the characterization of mucinous cystic lesions. CONCLUSIONS Acoustic Radiation Force Impulse imaging could help in the non-invasive characterization of solid and cystic lesions of the pancreas during a conventional US examination.
Collapse
Affiliation(s)
- Mirko D'Onofrio
- Department of Radiology, G.B. Rossi Hospital, University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy.
| | - Riccardo De Robertis
- Department of Radiology, G.B. Rossi Hospital, University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy
| | - Stefano Crosara
- Department of Radiology, G.B. Rossi Hospital, University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy
| | - Cristina Poli
- Department of Radiology, G.B. Rossi Hospital, University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy
| | - Stefano Canestrini
- Department of Radiology, G.B. Rossi Hospital, University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy
| | - Emanuele Demozzi
- Department of Radiology, G.B. Rossi Hospital, University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy
| | - Roberto Pozzi Mucelli
- Department of Radiology, G.B. Rossi Hospital, University of Verona, Piazzale L.A. Scuro 10, 37134 Verona, Italy
| |
Collapse
|
29
|
Liver and spleen stiffness and other noninvasive methods to assess portal hypertension in cirrhotic patients: a review of the literature. Eur J Gastroenterol Hepatol 2015; 27:992-1001. [PMID: 26020376 DOI: 10.1097/meg.0000000000000393] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Portal hypertension (PH) is one of the most important causes of morbidity and mortality in patients with chronic liver disease. PH measurement is crucial to stage and predict the clinical outcome of liver cirrhosis. Measurement of hepatic vein pressure gradient is considered the gold standard for assessment of the degree of PH; however, it is an invasive method and has not been used widely. Thus, noninvasive methods have been proposed recently. We critically evaluated serum markers, abdominal ultrasonography, and particularly liver and spleen stiffness measurement, which represent the more promising methods to stage PH degree and to assess the presence/absence of esophageal varices (EV). A literature search was carried out on MEDLINE, EMBASE, Web of Science, and Scopus for articles and abstracts. The search terms used included 'liver cirrhosis', 'portal hypertension', 'liver stiffness', 'spleen stiffness', 'ultrasonography', and 'portal hypertension serum biomarker'. The articles cited were selected on the basis of their relevance to the objective of the review. The results of available studies indicate that individually, these methods have a mild accuracy in predicting the presence of EV, and thus they cannot substitute endoscopy to predict EV. When these tests were used in combination, their accuracy increased. In addition to the PH staging, several serum markers and spleen stiffness measurement can predict the clinical outcome of liver cirrhosis with a good accuracy, comparable to that of hepatic vein pressure gradient. In the future, noninvasive methods could be used to select patients requiring further investigations to identify the best tailored clinical management.
Collapse
|
30
|
EASL-ALEH Clinical Practice Guidelines: Non-invasive tests for evaluation of liver disease severity and prognosis. J Hepatol 2015; 63:237-64. [PMID: 25911335 DOI: 10.1016/j.jhep.2015.04.006] [Citation(s) in RCA: 1178] [Impact Index Per Article: 130.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Accepted: 04/09/2015] [Indexed: 02/06/2023]
|
31
|
Deng Y, Palmeri ML, Rouze NC, Rosenzweig SJ, Abdelmalek MF, Nightingale KR. Analyzing the Impact of Increasing Mechanical Index and Energy Deposition on Shear Wave Speed Reconstruction in Human Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1948-57. [PMID: 25896024 PMCID: PMC4461469 DOI: 10.1016/j.ultrasmedbio.2015.02.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2014] [Revised: 02/25/2015] [Accepted: 02/25/2015] [Indexed: 05/03/2023]
Abstract
Shear wave elasticity imaging (SWEI) has found success in liver fibrosis staging. This work evaluates hepatic SWEI measurement success as a function of push pulse energy using two mechanical index (MI) values (1.6 and 2.2) over a range of pulse durations. Shear wave speed (SWS) was measured in the livers of 26 study subjects with known or potential chronic liver diseases. Each measurement consisted of eight SWEI sequences, each with different push energy configurations. The rate of successful SWS estimation was linearly proportional to the push energy. SWEI measurements with higher push energy were successful in patients for whom standard push energy levels failed. The findings also suggest that liver capsule depth could be used prospectively to identify patients who would benefit from elevated output. We conclude that there is clinical benefit to using elevated acoustic output for hepatic SWS measurement in patients with deeper livers.
Collapse
Affiliation(s)
- Yufeng Deng
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
| | - Mark L Palmeri
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Ned C Rouze
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Stephen J Rosenzweig
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Manal F Abdelmalek
- Department of Gastroenterology-Hepatology, Duke University Medical Center, Durham, North Carolina, USA
| | | |
Collapse
|
32
|
Ferraioli G, Filice C, Castera L, Choi BI, Sporea I, Wilson SR, Cosgrove D, Dietrich CF, Amy D, Bamber JC, Barr R, Chou YH, Ding H, Farrokh A, Friedrich-Rust M, Hall TJ, Nakashima K, Nightingale KR, Palmeri ML, Schafer F, Shiina T, Suzuki S, Kudo M. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1161-79. [PMID: 25800942 DOI: 10.1016/j.ultrasmedbio.2015.03.007] [Citation(s) in RCA: 440] [Impact Index Per Article: 48.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The World Federation for Ultrasound in Medicine and Biology (WFUMB) has produced these guidelines for the use of elastography techniques in liver disease. For each available technique, the reproducibility, results, and limitations are analyzed, and recommendations are given. Finally, recommendations based on the international literature and the findings of the WFUMB expert group are established as answers to common questions. The document has a clinical perspective and is aimed at assessing the usefulness of elastography in the management of liver diseases.
Collapse
Affiliation(s)
- Giovanna Ferraioli
- Ultrasound Unit, Department of Infectious Diseases, Fondazione IRCCS Policlinico S. Matteo, School of Medicine, University of Pavia, Pavia, Italy
| | - Carlo Filice
- Ultrasound Unit, Department of Infectious Diseases, Fondazione IRCCS Policlinico S. Matteo, School of Medicine, University of Pavia, Pavia, Italy
| | - Laurent Castera
- Service d'Hépatologie, Hôpital Beaujon, Clichy, Assistance Publique-Hôpitaux de Paris, INSERM U 773 CRB3, Université Denis Diderot Paris-VII, Paris, France
| | - Byung Ihn Choi
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Ioan Sporea
- Department of Gastroenterology and Hepatology, University of Medicine and Pharmacy, Timişoara, Romania
| | - Stephanie R Wilson
- Department of Diagnostic Imaging, Foothills Medical Centre, University of Calgary, Calgary, AB, Canada
| | - David Cosgrove
- Division of Radiology, Imperial and Kings Colleges, London, UK
| | | | - Dominique Amy
- Breast Center, 21 ave V. Hugo, 13100 Aix-en-Provence, France
| | - Jeffrey C Bamber
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK
| | - Richard Barr
- Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio and Radiology Consultants Inc., Youngstown, Ohio, USA
| | - Yi-Hong Chou
- Department of Radiology, Veterans General Hospital and National Yang-Ming University, School of Medicine, Taipei, Taiwan
| | - Hong Ding
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Andre Farrokh
- Department of Gynecology and Obstetrics, Franziskus Hospital, Bielefeld, Germany
| | - Mireen Friedrich-Rust
- Department of Internal Medicine 1, J. W. Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Timothy J Hall
- Department of Medical Physics, University of Wisconsin, Madison, WI, USA
| | | | | | - Mark L Palmeri
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Fritz Schafer
- Department of Breast Imaging and Interventions, University Hospital Schleswig-Holstein Campus, Kiel, Germany
| | - Tsuyoshi Shiina
- Department of Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Shinichi Suzuki
- Department of Endocrinology and Surgery, Fukushima University, Fukushima, Japan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Kinki University School of Medicine, Japan.
| |
Collapse
|
33
|
Knopf A, Hofauer B, Thürmel K, Meier R, Stock K, Bas M, Manour N. Diagnostic utility of Acoustic Radiation Force Impulse (ARFI) imaging in primary Sjoegren`s syndrome. Eur Radiol 2015; 25:3027-34. [PMID: 25861884 DOI: 10.1007/s00330-015-3705-4] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Revised: 01/26/2015] [Accepted: 03/04/2015] [Indexed: 12/14/2022]
Abstract
OBJECTIVES The purpose of the study was to assess the diagnostic utility of acoustic radiation force impulse (ARFI) imaging in primary Sjögren's syndrome (pSS). METHODS One hundred fifty-seven patients with sicca symptoms and/or salivary gland swelling were included. Sicca symptoms, Schirmer test, unstimulated whole saliva (UWS), SS-A/B antibodies, and histology were assessed according to American-European Consensus group (AECG) criteria. All patients underwent high-resolution ultrasound and ARFI imaging of the parotid (PG) and submandibular glands (SMG). RESULTS Seventy patients were classified as having pSS. The remaining 87 patients suffered from idiopathic sicca (n = 24), rheumatoid arthritis (n = 12), sarcoidosis (n = 9), cutaneous/systemic lupus erythematosus (n = 7), scleroderma (n = 2), dermatomyositis (n = 1), HBV/HCV (n = 2), and panarteritis nodosa (n = 1), and disorders in 29 patients were classified as not otherwise specified. ARFI values of the PG were significantly higher in the pSS versus non-pSS groups (2.86 ± 0.07 m/s vs. 2.15 ± 0.11 m/s, p < 0.0001). ARFI imaging demonstrated diagnostic sensitivity and specificity of 81 % and 67 %, respectively. CONCLUSIONS In addition to histology, ARFI imaging was the most important diagnostic tool for identifying early pSS. KEY POINTS • Early stages in Sjögren's syndrome become apparent with major salivary gland enlargements. • Schirmer and unstimulated whole saliva tests demonstrated insufficient sensitivity/specificity for early-stage diagnosis. • Acoustic radiation force impulse imaging is a reliable tool for diagnosing early disease stages.
Collapse
Affiliation(s)
- Andreas Knopf
- Hals-Nasen-Ohrenklinik und Poliklinik, Technische Universität München, Ismaningerstrasse 22, 81675, München, Germany,
| | | | | | | | | | | | | |
Collapse
|
34
|
Liao LY, Kuo KL, Chiang HS, Lin CZ, Lin YP, Lin CL. Acoustic radiation force impulse elastography of the liver in healthy patients: test location, reference range and influence of gender and body mass index. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:698-704. [PMID: 25638317 DOI: 10.1016/j.ultrasmedbio.2014.09.030] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2014] [Revised: 09/18/2014] [Accepted: 09/26/2014] [Indexed: 06/04/2023]
Abstract
The objective of this study was to evaluate the best test location and study factors associated with acoustic radiation force impulse (ARFI) elastography measurements in healthy individuals. When ARFI elastography was performed on 68 healthy patients after controlling for all known test condition factors except segmental location, the median shear wave velocities (SWVs) derived from five valid measurements in the area between S5 and S8 in patients in the supine position had a significantly lower mean and the narrowest 95% confidence interval, followed by those for the S8 supine and S8 semidecubitus locations (p = 0.045). Analysis of mean SWVs revealed similar, although statistically insignificant, findings (p = 0.078). Male patients had significantly higher median SWVs (p = 0.0073) and mean SWVs (p = 0.0043) than female patients. Patients with body mass indexes >22 had significantly lower median SWVs (p = 0.0033) and mean SWVs (p = 0.0008) than those with body mass indexes ≤22. S5/8 supine was the better test location for ARFI. The reference ranges for median and mean SWV were 0.81-1.27 and 0.82-1.27 m/s, respectively. Gender and body mass index, but not age, were the significant factors associated with ARFI SWV values.
Collapse
Affiliation(s)
- Li-Ying Liao
- Liver Center, Department of Gastroenterology, Taipei City Hospital Renai Branch, Taipei, Taiwan, Republic of China.
| | - Kuan-Liang Kuo
- Department of Family Medicine, Taipei City Hospital Renai Branch, Taipei, Taiwan, Republic of China
| | - Huei-Shin Chiang
- Liver Center, Department of Gastroenterology, Taipei City Hospital Renai Branch, Taipei, Taiwan, Republic of China
| | - Chong-Zong Lin
- Liver Center, Department of Gastroenterology, Taipei City Hospital Renai Branch, Taipei, Taiwan, Republic of China
| | - Yi-Ping Lin
- Taipei Databank for Public Health Analysis, Institute of Clinical Research and Training, Taipei City Hospital, Taipei, Taiwan, Republic of China
| | - Chih-Lin Lin
- Liver Center, Department of Gastroenterology, Taipei City Hospital Renai Branch, Taipei, Taiwan, Republic of China
| |
Collapse
|
35
|
Reliability analysis of acoustic radiation force impulse ultrasound imaging with virtual touch tissue quantification: ex vivo ox liver. Ultrasound Q 2015; 31:59-62. [PMID: 25706366 DOI: 10.1097/ruq.0000000000000070] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The effect of scanning angle and region of interest (ROI) depth on shear-wave velocity (SWV) was investigated in this study. Shear-wave velocity of ox liver ex vivo was measured with different approaches. Region of interest was set underneath the liver capsule at depths of 1, 2, 3, 4, and 5 cm. Three groups of measurements were performed at different scanning angles. One group of measurement was conducted with a scanning angle of 0 to 15 degrees from the midline, and the other 2 groups were performed with scanning angles of 15 to 30 degrees and 30 to 45 degrees. The data on SWV from different scan angles and ROI depths were analyzed statistically. Scanning angle and ROI depth were found to be the 2 factors that affect SWV. Interaction was observed between the scan angle and ROI depth. The data at different depths within 0- to 15-degree scanning angles exhibited no significant difference. However, the reliability of SWV decreased with the increase in ROI depth. In the groups of 15 to 30 degrees and 30 to 45 degrees, a significant difference was found between the 2 different measured depths. Scanning angle and ROI depth affected the reliability of SWV measurement. The scanning angle should be confined within 15 degrees from the midline. Therefore, SWV from shallow ROI is more reliable than that at deep ROI.
Collapse
|
36
|
Guo LH, Wang SJ, Xu HX, Sun LP, Zhang YF, Xu JM, Wu J, Fu HJ, Xu XH. Differentiation of benign and malignant focal liver lesions: value of virtual touch tissue quantification of acoustic radiation force impulse elastography. Med Oncol 2015; 32:68. [PMID: 25691297 DOI: 10.1007/s12032-015-0543-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2015] [Accepted: 02/13/2015] [Indexed: 12/12/2022]
Abstract
The purpose of this study was to investigate the value of virtual tissue quantification (VTQ) of acoustic radiation force impulse elastography for the differential diagnosis of benign and malignant focal liver lesions (FLLs). Thus, a total of 134 FLLs in 134 patients were included. VTQ measurement was performed for each lesion in which the shear wave velocity (SWV) was measured. The difference in SWV and SWV ratio of FLL to surrounding liver between malignant and benign FLLs was evaluated, and the cutoff value was investigated. Receiver operating characteristic (ROC) curve was plotted to evaluate the diagnostic performance. A total of 134 lesions including 55 (41.0%) malignant FLLs and 79 (59.0%) benign ones were analyzed. The SWV of malignant and benign FLLs was 2.95 ± 1.00 m/s and 1.69 ± 0.89 m/s, respectively. Significant difference in SWV was presented between malignant and benign FLLs (p < 0.001). The SWV ratio of each FLL to the surrounding liver parenchyma was 1.83 ± 1.32 for malignant and 1.26 ± 0.78 for benign FLLs (p < 0.001). The area under the ROC curve in distinguishing malignant from benign lesions was 0.824 for SWV and 0.660 for SWV ratio. The cutoff value for differential diagnosis was 2.13 m/s for SWV and 1.37 for SWV ratio. The associated sensitivity and specificity were 83.3 and 77.9% for SWV and 59.6 and 77.3% for SWV ratio, respectively. In conclusion, VTQ provides quantitative stiffness information of FLLs and is helpful in the differential diagnosis between malignant and benign FLLs, particularly for the patients who are not candidates for contrast-enhanced imaging such as CT, MRI or contrast-enhanced ultrasound.
Collapse
Affiliation(s)
- Le-Hang Guo
- Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Tenth People's Hospital of Tongji University, Shanghai, 200072, China
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Soresi M, Giannitrapani L, Cervello M, Licata A, Montalto G. Non invasive tools for the diagnosis of liver cirrhosis. World J Gastroenterol 2014; 20:18131-18150. [PMID: 25561782 PMCID: PMC4277952 DOI: 10.3748/wjg.v20.i48.18131] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Revised: 09/22/2014] [Accepted: 11/11/2014] [Indexed: 02/06/2023] Open
Abstract
Liver cirrhosis (LC), the end stage of many forms of chronic hepatitis of different etiologies is a diffuse process characterized by fibrosis and the conversion of normal liver architecture into structurally abnormal nodules surrounded by annular fibrosis. This chronic progressive clinical condition, leads to liver cell failure and portal hypertension, which can favour the onset of hepatocellular carcinoma. Defining the phase of the natural history is crucial for therapeutic choice and prognosis. Liver biopsy is currently considered the best available standard of reference but it has some limits, so alternative tools have been developed to substitute liver biopsy when assessing liver fibrosis. Serum markers offer a cost-effective alternative to liver biopsy being less invasive and theoretically without complications. They can be classified into direct and indirect markers which may be used alone or in combination to produce composite scores. Diagnostic imaging includes a number of instruments and techniques to estimate liver fibrosis and cirrhosis like ultrasound (US), US Doppler, contrast enhanced US and Elastography. US could be used for the diagnosis of advanced LC while is not able to evaluate progression of fibrosis, in this case Elastography is more reliable. This review aims to revise the most recent data from the literature about non invasive methods useful in defining liver fibrosis.
Collapse
|
38
|
Bob F, Bota S, Sporea I, Sirli R, Petrica L, Schiller A. Kidney shear wave speed values in subjects with and without renal pathology and inter-operator reproducibility of acoustic radiation force impulse elastography (ARFI)--preliminary results. PLoS One 2014; 9:e113761. [PMID: 25426849 PMCID: PMC4245225 DOI: 10.1371/journal.pone.0113761] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2014] [Accepted: 10/29/2014] [Indexed: 12/18/2022] Open
Abstract
AIM to assess the inter-operator reproducibility of kidney shear wave speed, evaluated by means of Acoustic Radiation Force Impulse (ARFI) elastography, and the factors which influence it. METHODS Our prospective pilot study included 107 subjects with or without kidney pathology in which kidney shear wave speed was evaluated by means of ARFI elastography. Intraclass correlation coefficient (ICC) was used to assess ARFI elastography reproducibility. RESULTS A strong agreement was obtained between kidney shear wave speed measurements obtained by the two operators: ICC = 0.71 (right kidney) and 0.69 (left kidney). Smaller ICCs were obtained in "healthy subjects", as compared to patients with kidney diseases (0.68 vs. 0.75), in women as compared with men (0.59 vs. 0.78), in subjects younger than 50 years as compared with those aged at least 50 years (0.63 vs. 0.71), in obese as compared with normal weight and overweight subjects (0.36 vs. 0.66 and 0.78) and in case of measurements depth <4 cm or >6 cm as compared with those performed at a depth of 4-6 cm from the skin (0.32 and 0.60 vs. 0.81). CONCLUSION ARFI elastography is a reproducible method for kidney shear wave speed assessment.
Collapse
Affiliation(s)
- Flaviu Bob
- Department of Nephrology, “Victor Babes” University of Medicine and Pharmacy, Timişoara, Romania
| | - Simona Bota
- Department of Gastroenterology and Hepatology, “Victor Babes” University of Medicine and Pharmacy, Timişoara, Romania
| | - Ioan Sporea
- Department of Gastroenterology and Hepatology, “Victor Babes” University of Medicine and Pharmacy, Timişoara, Romania
| | - Roxana Sirli
- Department of Gastroenterology and Hepatology, “Victor Babes” University of Medicine and Pharmacy, Timişoara, Romania
| | - Ligia Petrica
- Department of Nephrology, “Victor Babes” University of Medicine and Pharmacy, Timişoara, Romania
| | - Adalbert Schiller
- Department of Nephrology, “Victor Babes” University of Medicine and Pharmacy, Timişoara, Romania
| |
Collapse
|
39
|
Abstract
Elastography is a new technique that evaluates tissue stiffness. There are two elastography methods, strain and shear wave elastography. Both techniques are being used to evaluate a wide range of applications in medical imaging. Elastography of breast masses and prostates have been shown to have high accuracy for characterizing masses and can significantly decrease the need for biopsies. Shear wave elastography has been shown to be able to detect and grade liver fibrosis and may decrease the need for liver biopsy. Evaluation of other organs is still preliminary. This article reviews the principles of elastography and its potential clinical applications.
Collapse
Affiliation(s)
- Richard G Barr
- Department of Radiology, Northeastern Ohio Medical University, 4209 Ohio 44, Rootstown, OH 44272, USA; Southwoods Imaging, Radiology Consultants Inc, 7623 Market Street, Boardman, OH 44512, USA.
| |
Collapse
|
40
|
The role of CEUS in the assessment of haemodynamically stable patients with blunt abdominal trauma. Radiol Med 2014; 120:3-11. [PMID: 25142944 DOI: 10.1007/s11547-014-0455-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Accepted: 07/14/2014] [Indexed: 10/24/2022]
Abstract
Computed tomography (CT) still represents the preferred imaging method in the assessment of patients presenting with multiple trauma. Nevertheless, in patients with low-energy abdominal trauma, the use of CT is debated because of the possible unnecessary radiation exposure. Accordingly, conventional ultrasound (US) imaging has been increasingly employed as the initial imaging modality in the workup of minor traumatic emergency conditions. Focused assessment with sonography for trauma is widely used to detect free intra-abdominal fluid, but its role is controversial, because the absence of free fluid does not exclude the presence of injuries to abdominal organ. Injection of an ultrasound contrast agent (UCA) may give the radiologist relevant additional information to that obtained with conventional US. Thus, in trauma patients, following early assessment with conventional US imaging, a contrast-enhanced US (CEUS) can provide a more reliable evaluation of solid organ injuries and related vascular complications, including active bleeding, pseudoaneurysms, and artero-venous fistulas. CEUS cannot replace abdominal CT, but it represents a noninvasive and repeatable imaging tool capable of providing a reliable assessment of trauma severity and expedite the patient's treatment.
Collapse
|
41
|
De Robertis R, D’Onofrio M, Demozzi E, Crosara S, Canestrini S, Pozzi Mucelli R. Noninvasive diagnosis of cirrhosis: A review of different imaging modalities. World J Gastroenterol 2014; 20:7231-7241. [PMID: 24966594 PMCID: PMC4064069 DOI: 10.3748/wjg.v20.i23.7231] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2013] [Revised: 01/08/2014] [Accepted: 04/09/2014] [Indexed: 02/06/2023] Open
Abstract
Progressive hepatic fibrosis can lead to cirrhosis, so its early detection is fundamental. Staging fibrosis is also critical for prognosis and management. The gold standard for these aims is liver biopsy, but it has several drawbacks, as it is invasive, expensive, has poor acceptance, is prone to inter observer variability and sampling errors, has poor repeatability, and has a risk of complications and mortality. Therefore, non-invasive imaging tests have been developed. This review mainly focuses on the role of transient elastography, acoustic radiation force impulse imaging, and magnetic resonance-based methods for the noninvasive diagnosis of cirrhosis.
Collapse
|
42
|
Gerstenmaier JF, Gibson RN. Ultrasound in chronic liver disease. Insights Imaging 2014; 5:441-55. [PMID: 24859758 PMCID: PMC4141343 DOI: 10.1007/s13244-014-0336-2] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Revised: 04/16/2014] [Accepted: 04/17/2014] [Indexed: 12/17/2022] Open
Abstract
Background With the high prevalence of diffuse liver disease there is a strong clinical need for noninvasive detection and grading of fibrosis and steatosis as well as detection of complications. Methods B-mode ultrasound supplemented by portal system Doppler and contrast-enhanced ultrasound are the principal techniques in the assessment of liver parenchyma and portal venous hypertension and in hepatocellular carcinoma surveillance. Results Fibrosis can be detected and staged with reasonable accuracy using Transient Elastography and Acoustic Radiation Force Imaging. Newer elastography techniques are emerging that are undergoing validation and may further improve accuracy. Ultrasound grading of hepatic steatosis currently is predominantly qualitative. Conclusion A summary of methods including B-mode, Doppler, contrast-enhanced ultrasound and various elastography techniques, and their current performance in assessing the liver, is provided. Teaching Points • Diffuse liver disease is becoming more prevalent and there is a strong clinical need for noninvasive detection. • Portal hypertension can be best diagnosed by demonstrating portosystemic collateral venous flow. • B-mode US is the principal US technique supplemented by portal system Doppler. • B-mode US is relied upon in HCC surveillance, and CEUS is useful in the evaluation of possible HCC. • Fibrosis can be detected and staged with reasonable accuracy using TE and ARFI. • US detection of steatosis is currently reasonably accurate but grading of severity is of limited accuracy.
Collapse
Affiliation(s)
- J F Gerstenmaier
- Department of Radiology, (RNG also University of Melbourne) The Royal Melbourne Hospital, Grattan Street, Parkville, VIC, 3050, Australia,
| | | |
Collapse
|
43
|
Schiavon LDL, Narciso-Schiavon JL, Carvalho-Filho RJD. Non-invasive diagnosis of liver fibrosis in chronic hepatitis C. World J Gastroenterol 2014; 20:2854-2866. [PMID: 24659877 PMCID: PMC3961992 DOI: 10.3748/wjg.v20.i11.2854] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Revised: 12/20/2013] [Accepted: 01/15/2014] [Indexed: 02/06/2023] Open
Abstract
Assessment of liver fibrosis in chronic hepatitis C virus (HCV) infection is considered a relevant part of patient care and key for decision making. Although liver biopsy has been considered the gold standard for staging liver fibrosis, it is an invasive technique and subject to sampling errors and significant intra- and inter-observer variability. Over the last decade, several noninvasive markers were proposed for liver fibrosis diagnosis in chronic HCV infection, with variable performance. Besides the clear advantage of being noninvasive, a more objective interpretation of test results may overcome the mentioned intra- and inter-observer variability of liver biopsy. In addition, these tests can theoretically offer a more accurate view of fibrogenic events occurring in the entire liver with the advantage of providing frequent fibrosis evaluation without additional risk. However, in general, these tests show low accuracy in discriminating between intermediate stages of fibrosis and may be influenced by several hepatic and extra-hepatic conditions. These methods are either serum markers (usually combined in a mathematical model) or imaging modalities that can be used separately or combined in algorithms to improve accuracy. In this review we will discuss the different noninvasive methods that are currently available for the evaluation of liver fibrosis in chronic hepatitis C, their advantages, limitations and application in clinical practice.
Collapse
|
44
|
Ferraioli G, Tinelli C, Lissandrin R, Zicchetti M, Bernuzzi S, Salvaneschi L, Filice C. Ultrasound point shear wave elastography assessment of liver and spleen stiffness: effect of training on repeatability of measurements. Eur Radiol 2014; 24:1283-9. [PMID: 24643497 DOI: 10.1007/s00330-014-3140-y] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2013] [Revised: 02/11/2014] [Accepted: 02/27/2014] [Indexed: 12/16/2022]
Abstract
OBJECTIVES To evaluate reproducibility of measurements of spleen stiffness (SS) and liver stiffness (LS) at several sites by using point shear wave elastography (pSWE) and to investigate any training effect. METHODS Healthy volunteers were consecutively enrolled. Measurements of SS and LS were performed by an expert (observer 1) and a novice (observer 2) at three different sites of liver and spleen. To assess the effect of training the study was conducted in two periods (period 1 and period 2). Concordance correlation coefficient was used to assess intra-observer and inter-observer reproducibility. RESULTS A total of 92 subjects (67 men and 25 women) were enrolled in the study. Both intra-observer and inter-observer agreement were higher for the liver than for the spleen. Overall, the highest intra-observer and inter-observer agreement were obtained for the assessment of LS through intercostal space, and for measurements at this site there was a significantly better performance of observer 2 after the training period. For both observers, training improved the repeatability of SS measurements at all sites. A good intra-observer agreement was obtained only for measurements at the spleen lower pole. CONCLUSIONS The results of this study show that a learning curve in pSWE acquisition should be taken into account both for SS and LS measurements. KEY POINTS Reproducibility of SS measurements depends on the expertise of the operator. To achieve good reproducibility between measurements a training period is required. A learning curve in pSWE acquisition should be taken into account. SS measurements are less reproducible than LS measurements.
Collapse
Affiliation(s)
- Giovanna Ferraioli
- Ultrasound Unit - Infectious Diseases Department, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Via Taramelli 5, 27100, Pavia, Italy,
| | | | | | | | | | | | | |
Collapse
|
45
|
Czaja AJ. Review article: The prevention and reversal of hepatic fibrosis in autoimmune hepatitis. Aliment Pharmacol Ther 2014; 39:385-406. [PMID: 24387318 DOI: 10.1111/apt.12592] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2013] [Revised: 11/29/2013] [Accepted: 12/05/2013] [Indexed: 12/11/2022]
Abstract
BACKGROUND Immunosuppressive treatment of autoimmune hepatitis can prevent or reverse hepatic fibrosis, but these anti-fibrotic effects are inconsistent secondary gains. AIM To describe the anti-fibrotic effects of current therapies for autoimmune hepatitis, discuss the pathogenic mechanisms of hepatic fibrosis that might be targeted by anti-fibrotic interventions, indicate the non-invasive diagnostic tests of hepatic fibrosis that must be validated in autoimmune hepatitis and to suggest promising treatment opportunities. METHODS Studies cited in PubMed from 1972 to 2013 for autoimmune hepatitis, hepatic fibrosis, cirrhosis, anti-fibrotic therapy and non-invasive tests of hepatic fibrosis were selected. RESULTS Hepatic fibrosis improves in 53-57% of corticosteroid-treated patients with autoimmune hepatitis; progressive fibrosis slows or is prevented in 79%; and cirrhosis may be reversed. Progressive hepatic fibrosis is associated with liver inflammation, and the inability to fully suppress inflammatory activity within 12 months is associated with progression to cirrhosis (54%) and death or need for liver transplantation (15%). Liver tissue examination remains the gold standard for assessing hepatic fibrosis, but laboratory and radiological tests may be useful non-invasive methods to measure the fibrotic response. Severe liver inflammation can confound radiological assessments, and the preferred non-invasive test in autoimmune hepatitis is uncertain. Individualised treatment adjustments and adjunctive anti-fibrotic therapies are poised for study in this disease. CONCLUSIONS The prevention and reversal of hepatic fibrosis are achievable objectives in autoimmune hepatitis. Strategies that evaluate individualised therapies adjusted to the rapidity and completeness of the inflammatory response, and the use of adjunctive anti-fibrotic interventions, must be evaluated.
Collapse
Affiliation(s)
- A J Czaja
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, MN, USA
| |
Collapse
|
46
|
Fierbinteanu Braticevici C, Sporea I, Panaitescu E, Tribus L. Value of acoustic radiation force impulse imaging elastography for non-invasive evaluation of patients with nonalcoholic fatty liver disease. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1942-50. [PMID: 23932277 DOI: 10.1016/j.ultrasmedbio.2013.04.019] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2013] [Revised: 03/19/2013] [Accepted: 04/22/2013] [Indexed: 05/16/2023]
Abstract
The goals of the work described here were to evaluate the clinical utility of acoustic radiation force impulse (ARFI) elastography in differentiating non-alcoholic fatty liver disease (NAFLD) histologic subtypes and to determine if ARFI elastography measurements correlate with the severity of liver fibrosis. We compared ARFI elastography measurements with clinical, biologic and histologic features (simple steatosis or steatohepatitis) in 64 patients with histologically proven NAFLD. ARFI elastography is suitable for distinguishing patients with non-alcoholic steatohepatitis from those with simple steatosis, with an area under the receiver operating characteristic curve (AUROC) of 0.867 (95% confidence interval = 0.782-0.953). There was a highly significant correlation (r = 0.843) between ARFI elastography measurements and fibrosis (p < 0.001). In patients with non-alcoholic steatohepatitis, the diagnostic performance of ARFI elastography in predicting significant fibrosis (F ≥ 2) had an AUROC of 0.944. ARFI elastography better predicted F = 4 fibrosis (AUROC = 0.984). In conclusion, ARFI elastography is a promising method for differentiating patients with non-alcoholic steatohepatitis from patients with simple steatosis and can also predict significant fibrosis in these patients.
Collapse
Affiliation(s)
- Carmen Fierbinteanu Braticevici
- "Carol Davila" University of Medicine and Pharmacy, II Medical Clinic and Gastroenterology, University Hospital Bucharest, Bucharest, Romania.
| | | | | | | |
Collapse
|
47
|
Cui XW, Friedrich-Rust M, Molo CD, Ignee A, Schreiber-Dietrich D, Dietrich CF. Liver elastography, comments on EFSUMB elastography guidelines 2013. World J Gastroenterol 2013; 19:6329-6347. [PMID: 24151351 PMCID: PMC3801303 DOI: 10.3748/wjg.v19.i38.6329] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2013] [Revised: 08/11/2013] [Accepted: 09/17/2013] [Indexed: 02/06/2023] Open
Abstract
Recently the European Federation of Societies for Ultrasound in Medicine and Biology Guidelines and Recommendations have been published assessing the clinical use of ultrasound elastography. The document is intended to form a reference and to guide clinical users in a practical way. They give practical advice for the use and interpretation. Liver disease forms the largest section, reflecting published experience to date including evidence from meta-analyses with shear wave and strain elastography. In this review comments and illustrations on the guidelines are given.
Collapse
|
48
|
Bota S, Sporea I, Peck-Radosavljevic M, Sirli R, Tanaka H, Iijima H, Saito H, Ebinuma H, Lupsor M, Badea R, Fierbinteanu-Braticevici C, Petrisor A, Friedrich-Rust M, Sarrazin C, Takahashi H, Ono N, Piscaglia F, Marinelli S, D'Onofrio M, Gallotti A, Salzl P, Popescu A, Danila M. The influence of aminotransferase levels on liver stiffness assessed by Acoustic Radiation Force Impulse Elastography: a retrospective multicentre study. Dig Liver Dis 2013; 45:762-8. [PMID: 23510533 DOI: 10.1016/j.dld.2013.02.008] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2012] [Revised: 01/18/2013] [Accepted: 02/12/2013] [Indexed: 12/11/2022]
Abstract
BACKGROUND Acoustic Radiation Force Impulse Elastography is a new method for non-invasive evaluation of liver fibrosis. AIM To evaluate the impact of elevated alanine aminotransferase levels on liver stiffness assessment by Acoustic Radiation Force Impulse Elastography. METHODS A multicentre retrospective study including 1242 patients with chronic liver disease, who underwent liver biopsy and Acoustic Radiation Force Impulse. Transient Elastography was also performed in 512 patients. RESULTS The best Acoustic Radiation Force Impulse cut-off for predicting significant fibrosis was 1.29 m/s in cases with normal alanine aminotransferase levels and 1.44 m/s in patients with alanine aminotransferase levels>5 × the upper limit of normal. The best cut-off for predicting liver cirrhosis were 1.59 and 1.75 m/s, respectively. Acoustic Radiation Force Impulse cut-off for predicting significant fibrosis and cirrhosis were relatively similar in patients with normal alanine aminotransferase and in those with alanine aminotransferase levels between 1.1 and 5 × the upper limit of normal: 1.29 m/s vs. 1.36 m/s and 1.59 m/s vs. 1.57 m/s, respectively. For predicting cirrhosis, the Transient Elastography cut-offs were significantly higher in patients with alanine aminotransferase levels between 1.1 and 5 × the upper limit of normal compared to those with normal alanine aminotransferase: 12.3 kPa vs. 9.1 kPa. CONCLUSION Liver stiffness values assessed by Acoustic Radiation Force Impulse and Transient Elastography are influenced by high aminotransferase levels. Transient Elastography was also influenced by moderately elevated aminotransferase levels.
Collapse
Affiliation(s)
- Simona Bota
- Department of Gastroenterology and Hepatology, "Victor Babeş" University of Medicine and Pharmacy, Timisoara, Romania.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
49
|
D’Onofrio M, Crosara S, De Robertis R, Canestrini S, Demozzi E, Gallotti A, Mucelli RP. Acoustic radiation force impulse of the liver. World J Gastroenterol 2013; 19:4841-4849. [PMID: 23946588 PMCID: PMC3740413 DOI: 10.3748/wjg.v19.i30.4841] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2013] [Revised: 04/15/2013] [Accepted: 07/19/2013] [Indexed: 02/06/2023] Open
Abstract
Acoustic radiation force impulse (ARFI) imaging is a new and promising ultrasound-based diagnostic technique that, evaluating the wave propagation speed, allows the assessment of the tissue stiffness. ARFI is implemented in the ultrasound scanner. By short-duration acoustic radiation forces (less than 1 ms), localized displacements are generated in a selected region of interest not requiring any external compression so reducing the operator dependency. The generated wave scan provides qualitative or quantitative (wave velocity values) responses. Several non-invasive methods for assessing the staging of fibrosis are used, in order to avoid liver biopsy. Liver function tests and transient elastography are non-invasive, sensitive and accurate tools for the assessment of liver fibrosis and for the discrimination between cirrhotic and non-cirrhotic liver. Many published studies analyse ARFI performance and feasibility in studying diffuse liver diseases and compare them to other diagnostic imaging modalities such as conventional ultrasonography and transient elastography. Solid focal liver lesions, both benign and malignant, are common findings during abdominal examinations. The accurate characterization and differential diagnosis are important aims of all the imaging modalities available today. Only few papers describe the application of ARFI technology in the study of solid focal liver lesions, with different results. In the present study, the existing literature, to the best of our knowledge, about ARFI application on diffuse and focal liver pathology has been evaluated and results and statistical analyses have been compared, bringing to the conclusion that ARFI can be used in the study of the liver with similar accuracy as transient elastography in diagnosing significant fibrosis or cirrhosis and has got some advantages in respect to transient elastography since it does not require separate equipment, better displays anatomical structures and measurements can be successfully carried out almost in every patient.
Collapse
|
50
|
Bruno C, Caliari G, Zaffanello M, Brugnara M, Zuffante M, Cecchetto M, Minniti S, Pedot A, Talamini G, Pozzi-Mucelli R. Acoustic radiation force impulse (ARFI) in the evaluation of the renal parenchymal stiffness in paediatric patients with vesicoureteral reflux: preliminary results. Eur Radiol 2013; 23:3477-84. [PMID: 23881301 DOI: 10.1007/s00330-013-2959-y] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2012] [Revised: 06/04/2013] [Accepted: 06/07/2013] [Indexed: 02/06/2023]
Abstract
OBJECTIVES To prospectively evaluate acoustic radiation force impulse (ARFI) imaging of the kidneys in children with and without chronic renal disease. METHODS Twenty-eight children (age range 9-16 years) with primary or secondary vesicoureteral reflux (≥ grade III) underwent scintigraphy and ultrasound with ARFI. Kidneys were divided-according to scintigraphy-into "affected" and "contralateral"; the results were compared with 16 age-matched healthy subjects. An ARFI value, expressed as speed (m/s) of wave propagation through the tissue, was calculated for each kidney through the mean of the values obtained at the upper, middle and lower third. The Wilcoxon test was used; P values <0.05 were considered statistically significant. RESULTS The mean ARFI values obtained in the "affected" kidneys (5.70 ± 1.71 m/s) were significantly higher than those measured in both "contralateral" (4.09 ± 0.97, P < 0.0001) and "healthy" kidneys (3.13 ± 0.09, P < 0.0001). The difference between values in the "contralateral" kidneys and "healthy" ones was significant (P < 0.0001). The "affected" kidneys with secondary reflux had mean ARFI values (6.59 ± 1.45) significantly higher than those with primary reflux (5.35 ± 1.72). CONCLUSIONS ARFI values decrease from kidneys with secondary vesicoureteral reflux to kidneys with primary reflux to unaffected kidneys contralateral to reflux to normal kidneys.
Collapse
Affiliation(s)
- Costanza Bruno
- Department of Radiology, University of Verona, P.le L.A. Scuro 10, 37134, Verona, Italy,
| | | | | | | | | | | | | | | | | | | |
Collapse
|