Chen YK, Liu FY, Yen RF, Kao CH. Compare FDG-PET and Tc-99m tetrofosmin SPECT to detect metastatic thyroid carcinoma.
Acad Radiol 2003;
10:835-9. [PMID:
12945916 DOI:
10.1016/s1076-6332(03)00014-x]
[Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
RATIONALE AND OBJECTIVES
The effectiveness of 18-fluoro-2-deoxyglucose (FDG) positron emission tomography (PET) and technetium-99m tetrofosmin (Tc-99m TF) single photon emission computed tomography (SPECT) of neck and chest was evaluated to detect metastatic lesions in well-differentiated thyroid carcinoma after nearly total thyroidectomy and radioiodine (I-131) treatment who present with elevated serum human thyroglobulin levels but negative I-131 whole body scan.
MATERIALS AND METHODS
Twenty-three patients with differentiated thyroid carcinoma who underwent nearly total thyroidectomy and I-131 treatments were included in this study.
RESULTS
All of the 23 patients had negative I-131 whole body scan and elevated human thyroglobulin levels under thyroid-stimulating hormone stimulation. Metastatic lesions were detected by FDG-PET in 20 patients, while Tc-99m TF SPECT revealed metastatic lesions in only 11 of the 20 patients. Both FDG-PET and Tc-99m TF SPECT failed to demonstrate miliary pulmonary metastases in two of the remaining three patients. The other patient did not show any lesion on FDG-PET, Tc-99m TF SPECT, chest computed tomography, or other imaging techniques.
CONCLUSION
This study demonstrated that FDG-PET is more sensitive than Tc-99m TF SPECT to detect metastatic lesions in differentiated thyroid carcinoma with elevated human thyroglobulin but negative I-131 whole body scan. However, miliary pulmonary metastases could be missed by the both techniques.