1
|
Nashimoto Y. [Drugs and cellular dynamics in tumor microenvironment using microphysiological systems]. Nihon Yakurigaku Zasshi 2025; 160:97-101. [PMID: 40024713 DOI: 10.1254/fpj.24063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2025]
Abstract
The tumor microenvironment (TME) includes immune cells, cancer-associated fibroblasts (CAFs), endothelial cells, pericytes, and more. Previously, these non-cancer cells were considered inactive components in cancer pathology. However, it has become evident that these cells and their secretions play crucial roles in cancer progression. To unravel the complexity of the TME and elucidate its mechanisms, microphysiological systems (MPS) have gained attention. An MPS is defined as "a microscale cell culture platform for in vitro modeling of functional features of a specific tissue or organ of human or animal origin", allowing for the control of the chemical or physical conditions of the TME and the analysis of the responses of cancer cells and surrounding cells. In recent years, the incorporation of vascular networks into tumor MPS has enabled more accurate assessments of the dynamics within the TME. This review provides an overview of the latest research on cancer MPS with vascular networks and the cellular and molecular dynamics within the TME.
Collapse
Affiliation(s)
- Yuji Nashimoto
- Laboratory for Bioengineering and Biomaterials, Institute of Science Tokyo
| |
Collapse
|
2
|
Ahmadi F, Tran H, Letourneau N, Little SR, Fortin A, Moraitis AN, Shih SCC. An Automated Single-Cell Droplet-Digital Microfluidic Platform for Monoclonal Antibody Discovery. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2308950. [PMID: 38441226 DOI: 10.1002/smll.202308950] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 01/30/2024] [Indexed: 06/27/2024]
Abstract
Monoclonal antibody (mAb) discovery plays a prominent role in diagnostic and therapeutic applications. Droplet microfluidics has become a standard technology for high-throughput screening of antibody-producing cells due to high droplet single-cell confinement frequency and rapid analysis and sorting of the cells of interest with their secreted mAbs. In this work, a new method is described for on-demand co-encapsulation of cells that eliminates the difficulties associated with washing in between consecutive steps inside the droplets and enables the washing and addition of fresh media. The new platform identifies hybridoma cells that are expressing antibodies of interest using antibody-characterization assays to find the best-performing or rare-cell antibody candidates.
Collapse
Affiliation(s)
- Fatemeh Ahmadi
- Department of Electrical and Computer Engineering, Concordia University, 1455 de Maisonneuve Blvd. West, Montréal, Québec, H3G 1M8, Canada
- Centre for Applied Synthetic Biology, Concordia University, 7141 Sherbrooke Street West, Montréal, Québec, H4B 1R6, Canada
| | - Hao Tran
- Department of Electrical and Computer Engineering, Concordia University, 1455 de Maisonneuve Blvd. West, Montréal, Québec, H3G 1M8, Canada
| | - Natasha Letourneau
- Department of Biology, Concordia University, 7141 Sherbrooke Street West, Montréal, Québec, H4B 1R6, Canada
| | - Samuel R Little
- Department of Electrical and Computer Engineering, Concordia University, 1455 de Maisonneuve Blvd. West, Montréal, Québec, H3G 1M8, Canada
- Centre for Applied Synthetic Biology, Concordia University, 7141 Sherbrooke Street West, Montréal, Québec, H4B 1R6, Canada
| | - Annie Fortin
- Human Health Therapeutics Research Centre, National Research Council Canada, Montréal, Québec, H4P 2R2, Canada
| | - Anna N Moraitis
- Human Health Therapeutics Research Centre, National Research Council Canada, Montréal, Québec, H4P 2R2, Canada
| | - Steve C C Shih
- Department of Electrical and Computer Engineering, Concordia University, 1455 de Maisonneuve Blvd. West, Montréal, Québec, H3G 1M8, Canada
- Centre for Applied Synthetic Biology, Concordia University, 7141 Sherbrooke Street West, Montréal, Québec, H4B 1R6, Canada
- Department of Biology, Concordia University, 7141 Sherbrooke Street West, Montréal, Québec, H4B 1R6, Canada
| |
Collapse
|
3
|
Lin JL, Hsu PP, Kuo JN. Magnetic Beads inside Droplets for Agitation and Splitting Manipulation by Utilizing a Magnetically Actuated Platform. MICROMACHINES 2023; 14:1349. [PMID: 37512660 PMCID: PMC10384566 DOI: 10.3390/mi14071349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/28/2023] [Accepted: 06/29/2023] [Indexed: 07/30/2023]
Abstract
We successfully developed a platform for the magnetic manipulation of droplets containing magnetic beads and examined the washing behaviors of the droplets, including droplet transportation, magnetic bead agitation inside droplets, and separation from parent droplets. Magnetic field gradients were produced with two layers of 6 × 1 planar coils fabricated by using printed circuit board technology. We performed theoretical analyses to understand the characteristics of the coils and successfully predicted the magnetic field and thermal temperature of a single coil. We then investigated experimentally the agitation and splitting kinetics of the magnetic beads inside droplets and experimentally observed the washing performance in different neck-shaped gaps. The performance of the washing process was evaluated by measuring both the particle loss ratio and the optical density. The findings of this work will be used to design a magnetic-actuated droplet platform, which will separate magnetic beads from their parent droplets and enhance washing performance. We hope that this study will provide digital microfluidics for application in point-of-care testing. The developed microchip will be of great benefit for genetic analysis and infectious disease detection in the future.
Collapse
Affiliation(s)
- Jr-Lung Lin
- Department of Mechanical and Automation Engineering, I-Shou University, Kaohsiung 84001, Taiwan
| | - Pei-Pei Hsu
- Department of Mechanical and Automation Engineering, I-Shou University, Kaohsiung 84001, Taiwan
| | - Ju-Nan Kuo
- Department of Automation Engineering, National Formosa University, No. 64, Wenhua Rd., Yunlin 63201, Taiwan
| |
Collapse
|
4
|
|
5
|
Siedlik MJ, Issadore D. Pico-washing: simultaneous liquid addition and removal for continuous-flow washing of microdroplets. MICROSYSTEMS & NANOENGINEERING 2022; 8:46. [PMID: 35498338 PMCID: PMC9050730 DOI: 10.1038/s41378-022-00381-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/02/2022] [Accepted: 03/07/2022] [Indexed: 05/19/2023]
Abstract
Droplet microfluidics is based on a toolbox of several established unit operations, including droplet generation, incubation, mixing, pico-injection, and sorting. In the last two decades, the development of droplet microfluidic systems, which incorporate these multiple unit operations into a workflow, has demonstrated unique capabilities in fields ranging from single-cell transcriptomic analyses to materials optimization. One unit operation that is sorely underdeveloped in droplet microfluidics is washing, exchange of the fluid in a droplet with a different fluid. Here, we demonstrate what we name the "pico-washer," a unit operation capable of simultaneously adding fluid to and removing fluid from droplets in flow while requiring only a small footprint on a microfluidic chip. We describe the fabrication strategy, device architecture, and process parameters required for stable operation of this technology, which is capable of operating with kHz droplet throughput. Furthermore, we provide an image processing workflow to characterize the washing process with microsecond and micrometer resolution. Finally, we demonstrate the potential for integrated droplet workflows by arranging two of these unit operations in series with a droplet generator, describe a design rule for stable operation of the pico-washer when integrated into a system, and validate this design rule experimentally. We anticipate that this technology will contribute to continued development of the droplet microfluidics toolbox and the realization of novel droplet-based, multistep biological and chemical assays.
Collapse
Affiliation(s)
- Michael J. Siedlik
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104 United States
| | - David Issadore
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104 United States
- Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, PA 19104 United States
| |
Collapse
|
6
|
Gerlt MS, Ruppen P, Leuthner M, Panke S, Dual J. Acoustofluidic medium exchange for preparation of electrocompetent bacteria using channel wall trapping. LAB ON A CHIP 2021; 21:4487-4497. [PMID: 34668506 PMCID: PMC8577197 DOI: 10.1039/d1lc00406a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 10/13/2021] [Indexed: 06/02/2023]
Abstract
Comprehensive integration of process steps into a miniaturised version of synthetic biology workflows remains a crucial task in automating the design of biosystems. However, each of these process steps has specific demands with respect to the environmental conditions, including in particular the composition of the surrounding fluid, which makes integration cumbersome. As a case in point, transformation, i.e. reprogramming of bacteria by delivering exogenous genetic material (such as DNA) into the cytoplasm, is a key process in molecular engineering and modern biotechnology in general. Transformation is often performed by electroporation, i.e. creating pores in the membrane using electric shocks in a low conductivity environment. However, cell preparation for electroporation can be cumbersome as it requires the exchange of growth medium (high-conductivity) for low-conductivity medium, typically performed via multiple time-intensive centrifugation steps. To simplify and miniaturise this step, we developed an acoustofluidic device capable of trapping the bacterium Escherichia coli non-invasively for subsequent exchange of medium, which is challenging in acoustofluidic devices due to detrimental acoustic streaming effects. With an improved etching process, we were able to produce a thin wall between two microfluidic channels, which, upon excitation, can generate streaming fields that complement the acoustic radiation force and therefore can be utilised for trapping of bacteria. Our novel design robustly traps Escherichia coli at a flow rate of 10 μL min-1 and has a cell recovery performance of 47 ± 3% after washing the trapped cells. To verify that the performance of the medium exchange device is sufficient, we tested the electrocompetence of the recovered cells in a standard transformation procedure and found a transformation efficiency of 8 × 105 CFU per μg of plasmid DNA. Our device is a low-volume alternative to centrifugation-based methods and opens the door for miniaturisation of a plethora of microbiological and molecular engineering protocols.
Collapse
Affiliation(s)
- M S Gerlt
- Mechanics and Experimental Dynamics, Department of Mechanical and Process Engineering, Swiss Federal Institute of Technology (ETH Zurich), Tannenstrasse 3, CH-8092 Zurich, Switzerland.
| | - P Ruppen
- Bioprocess Laboratory, Department of Biosystems Science and Engineering, Swiss Federal Institute of Technology (ETH Zurich), Mattenstrasse 26, CH-4058 Basel, Switzerland.
- NCCR Molecular Systems Engineering, BPR 1095, Mattenstrasse 24a, CH-4058 Basel, Switzerland
| | - M Leuthner
- Mechanics and Experimental Dynamics, Department of Mechanical and Process Engineering, Swiss Federal Institute of Technology (ETH Zurich), Tannenstrasse 3, CH-8092 Zurich, Switzerland.
| | - S Panke
- Bioprocess Laboratory, Department of Biosystems Science and Engineering, Swiss Federal Institute of Technology (ETH Zurich), Mattenstrasse 26, CH-4058 Basel, Switzerland.
- NCCR Molecular Systems Engineering, BPR 1095, Mattenstrasse 24a, CH-4058 Basel, Switzerland
| | - J Dual
- Mechanics and Experimental Dynamics, Department of Mechanical and Process Engineering, Swiss Federal Institute of Technology (ETH Zurich), Tannenstrasse 3, CH-8092 Zurich, Switzerland.
| |
Collapse
|
7
|
Van Lent J, Breukers J, Ven K, Ampofo L, Horta S, Pollet F, Imbrechts M, Geukens N, Vanhoorelbeke K, Declerck P, Lammertyn J. Miniaturized single-cell technologies for monoclonal antibody discovery. LAB ON A CHIP 2021; 21:3627-3654. [PMID: 34505611 DOI: 10.1039/d1lc00243k] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Antibodies (Abs) are among the most important class of biologicals, showcasing a high therapeutic and diagnostic value. In the global therapeutic Ab market, fully-human monoclonal Abs (FH-mAbs) are flourishing thanks to their low immunogenicity and high specificity. The rapidly emerging field of single-cell technologies has paved the way to efficiently discover mAbs by facilitating a fast screening of the antigen (Ag)-specificity and functionality of Abs expressed by B cells. This review summarizes the principles and challenges of the four key concepts to discover mAbs using these technologies, being confinement of single cells using either droplet microfluidics or microstructure arrays, identification of the cells of interest, retrieval of those cells and single-cell sequence determination required for mAb production. This review reveals the enormous potential for mix-and-matching of the above-mentioned strategies, which is illustrated by the plethora of established, highly integrated devices. Lastly, an outlook is given on the many opportunities and challenges that still lie ahead to fully exploit miniaturized single-cell technologies for mAb discovery.
Collapse
Affiliation(s)
- Julie Van Lent
- Department of Biosystems, Biosensors Group, KU Leuven, Leuven 3001, Belgium.
| | - Jolien Breukers
- Department of Biosystems, Biosensors Group, KU Leuven, Leuven 3001, Belgium.
| | - Karen Ven
- Department of Biosystems, Biosensors Group, KU Leuven, Leuven 3001, Belgium.
| | - Louanne Ampofo
- Department of Biosystems, Biosensors Group, KU Leuven, Leuven 3001, Belgium.
- Laboratory for Therapeutic and Diagnostic Antibodies, KU Leuven, Leuven 3000, Belgium
| | - Sara Horta
- Laboratory for Thrombosis Research, IRF Life Sciences, KU Leuven Campus Kulak Kortrijk, Kortrijk 8500, Belgium
| | - Francesca Pollet
- Department of Biosystems, Biosensors Group, KU Leuven, Leuven 3001, Belgium.
| | - Maya Imbrechts
- Laboratory for Therapeutic and Diagnostic Antibodies, KU Leuven, Leuven 3000, Belgium
- PharmAbs, The KU Leuven Antibody Center, KU Leuven, Leuven 3000, Belgium
| | - Nick Geukens
- PharmAbs, The KU Leuven Antibody Center, KU Leuven, Leuven 3000, Belgium
| | - Karen Vanhoorelbeke
- Laboratory for Thrombosis Research, IRF Life Sciences, KU Leuven Campus Kulak Kortrijk, Kortrijk 8500, Belgium
- PharmAbs, The KU Leuven Antibody Center, KU Leuven, Leuven 3000, Belgium
| | - Paul Declerck
- Laboratory for Therapeutic and Diagnostic Antibodies, KU Leuven, Leuven 3000, Belgium
- PharmAbs, The KU Leuven Antibody Center, KU Leuven, Leuven 3000, Belgium
| | - Jeroen Lammertyn
- Department of Biosystems, Biosensors Group, KU Leuven, Leuven 3001, Belgium.
| |
Collapse
|
8
|
Huang C, Zhang H, Han SI, Han A. Cell Washing and Solution Exchange in Droplet Microfluidic Systems. Anal Chem 2021; 93:8622-8630. [PMID: 34110770 DOI: 10.1021/acs.analchem.1c01558] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Water-in-oil emulsion droplet microfluidic systems have been extensively developed, and currently, almost all cell handling steps can be conducted in this format. An exception is the cell washing and solution exchange step, which is commonly utilized in many conventional cell assays. This paper presents an in-droplet cell washing and solution exchange technology that utilizes dielectrophoretic (DEP) force to move all cells to one side of a droplet, followed by asymmetrical splitting of the droplet to obtain a small daughter droplet that contains all or most of the cells, and then finally merges this cell-concentrated droplet with a new droplet that contains the desired solution. These sequential droplet manipulation steps were integrated into a single platform, where up to 88% of the original solution in the droplet could be exchanged with the new solution while keeping cell loss to less than 5%. Two application examples were demonstrated using the developed technology. In the first example, green microalga Chlamydomonas reinhardtii cells were manipulated using negative DEP force to exchange the regular culture medium with a nitrogen-limited medium to induce lipid production. In the second example, Salmonella enterica cells were manipulated using positive DEP force to replace fluorescent dye that models fluorescent cell stains that contribute to high background noise in fluorescence-based droplet content detection with fresh buffer solution, significantly improving the droplet content detection sensitivity. Since the cell washing step is one of the most frequently utilized steps in many cell biology assays, we expect that the developed technology can significantly broaden the type of assay that can be conducted in droplet microfluidic format.
Collapse
Affiliation(s)
- Can Huang
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Han Zhang
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Song-I Han
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Arum Han
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
9
|
Payne EM, Holland-Moritz DA, Sun S, Kennedy RT. High-throughput screening by droplet microfluidics: perspective into key challenges and future prospects. LAB ON A CHIP 2020; 20:2247-2262. [PMID: 32500896 DOI: 10.1039/d0lc00347f] [Citation(s) in RCA: 87] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
In two decades of development, impressive strides have been made for automating basic laboratory operations in droplet-based microfluidics, allowing the emergence of a new form of high-throughput screening and experimentation in nanoliter to femtoliter volumes. Despite advancements in droplet storage, manipulation, and analysis, the field has not yet been widely adapted for many high-throughput screening (HTS) applications. Broad adoption and commercial development of these techniques require robust implementation of strategies for the stable storage, chemical containment, generation of libraries, sample tracking, and chemical analysis of these small samples. We discuss these challenges for implementing droplet HTS and highlight key strategies that have begun to address these concerns. Recent advances in the field leave us optimistic about the future prospects of this rapidly developing technology.
Collapse
Affiliation(s)
- Emory M Payne
- Department of Chemistry, University of Michigan, Ann Arbor, MI, USA.
| | | | | | | |
Collapse
|
10
|
Liu Z, Fornell A, Barbe L, Hjort K, Tenje M. On-chip background dilution in droplets with high particle recovery using acoustophoresis. BIOMICROFLUIDICS 2019; 13:064123. [PMID: 31832121 PMCID: PMC6897560 DOI: 10.1063/1.5129256] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Accepted: 11/19/2019] [Indexed: 05/02/2023]
Abstract
Droplet microfluidics has shown great potential for on-chip biological and chemical assays. However, fluid exchange in droplet microfluidics with high particle recovery is still a major bottleneck. Here, using acoustophoresis, we present for the first time a label-free method to achieve continuous background dilution in droplets containing cells with high sample recovery. The system comprises droplet generation, acoustic focusing, droplet splitting, picoinjection, and serpentine mixing on the same chip. The capacities of the picoinjection and the droplet split to dilute the background fluorescent signal in the droplets have been characterized. The sample recovery at different droplet split ratios has also been characterized. The results show a maximum of 4.3-fold background dilution with 87.7% particle recovery. We also demonstrated that the system can be used to dilute background fluorescent signal in droplets containing either polystyrene particles or endothelial cells.
Collapse
Affiliation(s)
| | | | | | - Klas Hjort
- Department of Engineering Sciences, Uppsala University, 75271 Uppsala, Sweden
| | | |
Collapse
|
11
|
Liang D, Ma P, Zhu C, Fu T, Ma Y, Wang K, Luo G. Manipulable Formation of Ferrofluid Droplets in Y-Shaped Flow-Focusing Microchannels. Ind Eng Chem Res 2019. [DOI: 10.1021/acs.iecr.9b02516] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Di Liang
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China
| | - Pengcheng Ma
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China
| | - Chunying Zhu
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China
| | - Taotao Fu
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China
| | - Youguang Ma
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China
| | - Kai Wang
- State Key Laboratory of Chemical Engineering, Department of Chemical Engineering, Tsinghua University, Beijing 100084, P. R. China
| | - Guangsheng Luo
- State Key Laboratory of Chemical Engineering, Department of Chemical Engineering, Tsinghua University, Beijing 100084, P. R. China
| |
Collapse
|
12
|
Fast fluorometric enumeration of E. coli using passive chip. J Microbiol Methods 2019; 164:105680. [DOI: 10.1016/j.mimet.2019.105680] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 07/31/2019] [Accepted: 08/01/2019] [Indexed: 01/06/2023]
|
13
|
Doonan SR, Lin M, Bailey RC. Droplet CAR-Wash: continuous picoliter-scale immunocapture and washing. LAB ON A CHIP 2019; 19:1589-1598. [PMID: 30963149 PMCID: PMC6478530 DOI: 10.1039/c9lc00125e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
To address current limitations in adapting solid phase sample capture and washing techniques to continuously flowing droplet microfluidics, we have developed the "Coalesce-Attract-Resegment Wash" (CAR-Wash) approach. This module provides efficient, high-throughput magnetic washing by electrocoalescing magnetic bead-laden input droplets with a washing buffer flow and magnetophoretically transporting beads through the buffer into a secondary droplet formation streamline. In this work, we first characterized the technology in terms of throughput, sample retention, and flow-based exclusion of waste volume, demonstrating >500 Hz droplet processing with >98% bead retention and >100-fold dilution in final droplets. Next, we showed that the technique can be adapted to alternative commercially available magnetic beads with lower magnetite content per particle. Then, we demonstrated the CAR-Wash module's effectiveness in washing away a small molecule competitive inhibitor to restore the activity of magnetic bead-immobilized β-galactosidase. Finally, we applied the system to immunomagnetically enrich a green fluorescent protein-histone H2B fusion protein from cell lysate while washing away mCherry and other lysate components. We believe this approach will bridge the gap between powerful biochemical and bioanalytical techniques and current droplet microfluidic capabilities, and we envision future application in droplet-based immunoassays, solid phase extraction, and other complex, multi-step operations.
Collapse
Affiliation(s)
- Steven R Doonan
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA.
| | | | | |
Collapse
|
14
|
Wang X, Liu Z, Pang Y. Droplet breakup in an asymmetric bifurcation with two angled branches. Chem Eng Sci 2018. [DOI: 10.1016/j.ces.2018.05.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
15
|
Park J, Destgeer G, Kim H, Cho Y, Sung HJ. In-droplet microparticle washing and enrichment using surface acoustic wave-driven acoustic radiation force. LAB ON A CHIP 2018; 18:2936-2945. [PMID: 30140820 DOI: 10.1039/c8lc00733k] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Washing and enrichment of particles and cells are crucial sample preparation procedures in biomedical and biochemical assays. On-chip in-droplet microparticle washing and enrichment have been pursued but remained problematic due to technical difficulties, especially simultaneous and precise control over the droplet interface and in-droplet samples. Here, we have achieved a breakthrough in label-free, continuous, on-demand, in-droplet microparticle washing and enrichment using surface acoustic waves. When exposed to the acoustic field, the droplet and suspended particles experience acoustic radiation force arising from inhomogeneous wave scattering at the liquid/liquid and liquid/solid interfaces. Based on these acoustophoretic phenomena, we have demonstrated in-droplet microparticle washing and enrichment in an acoustofluidic device. We expect that the proposed acoustic method will offer new perspectives to sample washing and enrichment by performing the operation in microscale droplets.
Collapse
Affiliation(s)
- Jinsoo Park
- Department of Mechanical Engineering, KAIST, Daejeon 34141, Korea.
| | | | | | | | | |
Collapse
|
16
|
Stephenson W. High-throughput magnetic particle washing in nanoliter droplets using serial injection and splitting. MICRO AND NANO SYSTEMS LETTERS 2018. [DOI: 10.1186/s40486-018-0065-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
17
|
Serra M, Ferraro D, Pereiro I, Viovy JL, Descroix S. The power of solid supports in multiphase and droplet-based microfluidics: towards clinical applications. LAB ON A CHIP 2017; 17:3979-3999. [PMID: 28948991 DOI: 10.1039/c7lc00582b] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Multiphase and droplet microfluidic systems are growing in relevance in bioanalytical-related fields, especially due to the increased sensitivity, faster reaction times and lower sample/reagent consumption of many of its derived bioassays. Often applied to homogeneous (liquid/liquid) reactions, innovative strategies for the implementation of heterogeneous (typically solid/liquid) processes have recently been proposed. These involve, for example, the extraction and purification of target analytes from complex matrices or the implementation of multi-step protocols requiring efficient washing steps. To achieve this, solid supports such as functionalized particles (micro or nanometric) presenting different physical properties (e.g. magnetic, optical or others) are used for the binding of specific entities. The manipulation of such supports with different microfluidic principles has both led to the miniaturization of existing biomedical protocols and the development of completely new strategies for diagnostics and research. In this review, multiphase and droplet-based microfluidic systems using solid suspensions are presented and discussed with a particular focus on: i) working principles and technological developments of the manipulation strategies and ii) applications, critically discussing the level of maturity of these systems, which can range from initial proofs of concept to real clinical validations.
Collapse
Affiliation(s)
- M Serra
- Laboratoire Physico Chimie Curie, Institut Curie, PSL Research University, CNRS UMR168, Paris, France.
| | | | | | | | | |
Collapse
|
18
|
Park K, Park J, Jung JH, Destgeer G, Ahmed H, Sung HJ. In-droplet microparticle separation using travelling surface acoustic wave. BIOMICROFLUIDICS 2017; 11:064112. [PMID: 29308101 PMCID: PMC5739910 DOI: 10.1063/1.5010219] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Accepted: 12/11/2017] [Indexed: 05/05/2023]
Abstract
Droplets in microfluidic systems can contain microscale objects such as cells and microparticles. The control of the positions of microscale objects within a microchannel is crucial for practical applications in not only continuous-flow-based but also droplet-based systems. This paper proposes an active method for the separation of microparticles inside moving droplets which uses travelling surface acoustic waves (TSAWs). We demonstrate the preconcentration and separation of 5 and 10 μm polystyrene microparticles in moving water-in-oil droplets through the application of TSAWs with two different frequencies. The microparticles inside the droplets are affected by the acoustic radiation force induced by the TSAWs to move laterally in the direction of the TSAW propagation and are thereby separated according to their size. In-droplet separation is then demonstrated through droplet splitting at a Y-junction. Compared to our previous studies, this acoustic approach offers the label-free and on-demand separation of different-sized micro-objects in moving droplets. The present method has potential uses such as in-droplet sample purification and enrichment.
Collapse
Affiliation(s)
- Kwangseok Park
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea
| | - Jinsoo Park
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea
| | - Jin Ho Jung
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea
| | - Ghulam Destgeer
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea
| | - Husnain Ahmed
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea
| | - Hyung Jin Sung
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, South Korea
| |
Collapse
|
19
|
Han SI, Soo Kim H, Han A. In-droplet cell concentration using dielectrophoresis. Biosens Bioelectron 2017; 97:41-45. [DOI: 10.1016/j.bios.2017.05.036] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2017] [Revised: 04/28/2017] [Accepted: 05/18/2017] [Indexed: 10/19/2022]
|
20
|
Doonan SR, Bailey RC. K-Channel: A Multifunctional Architecture for Dynamically Reconfigurable Sample Processing in Droplet Microfluidics. Anal Chem 2017; 89:4091-4099. [PMID: 28222260 PMCID: PMC5812353 DOI: 10.1021/acs.analchem.6b05041] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
By rapidly creating libraries of thousands of unique, miniaturized reactors, droplet microfluidics provides a powerful method for automating high-throughput chemical analysis. In order to engineer in-droplet assays, microfluidic devices must add reagents into droplets, remove fluid from droplets, and perform other necessary operations, each typically provided by a unique, specialized geometry. Unfortunately, modifying device performance or changing operations usually requires re-engineering the device among these specialized geometries, a time-consuming and costly process when optimizing in-droplet assays. To address this challenge in implementing droplet chemistry, we have developed the "K-channel," which couples a cross-channel flow to the segmented droplet flow to enable a range of operations on passing droplets. K-channels perform reagent injection (0-100% of droplet volume), fluid extraction (0-50% of droplet volume), and droplet splitting (1:1-1:5 daughter droplet ratio). Instead of modifying device dimensions or channel configuration, adjusting external conditions, such as applied pressure and electric field, selects the K-channel process and tunes its magnitude. Finally, interfacing a device-embedded magnet allows selective capture of 96% of droplet-encapsulated superparamagnetic beads during 1:1 droplet splitting events at ∼400 Hz. Addition of a second K-channel for injection (after the droplet splitting K-channel) enables integrated washing of magnetic beads within rapidly moving droplets. Ultimately, the K-channel provides an exciting opportunity to perform many useful droplet operations across a range of magnitudes without requiring architectural modifications. Therefore, we envision the K-channel as a versatile, easy to use microfluidic component enabling diverse, in-droplet (bio)chemical manipulations.
Collapse
Affiliation(s)
- Steven R. Doonan
- Department of Chemistry, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801, USA
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA
| | - Ryan C. Bailey
- Department of Chemistry, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801, USA
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
21
|
Wang S, Sung KJ, Lin XN, Burns MA. Bead mediated separation of microparticles in droplets. PLoS One 2017; 12:e0173479. [PMID: 28282412 PMCID: PMC5345812 DOI: 10.1371/journal.pone.0173479] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Accepted: 02/21/2017] [Indexed: 11/25/2022] Open
Abstract
Exchange of components such as particles and cells in droplets is important and highly desired in droplet microfluidic assays, and many current technologies use electrical or magnetic fields to accomplish this process. Bead-based microfluidic techniques offer an alternative approach that uses the bead's solid surface to immobilize targets like particles or biological material. In this paper, we demonstrate a bead-based technique for exchanging droplet content by separating fluorescent microparticles in a microfluidic device. The device uses posts to filter surface-functionalized beads from a droplet and re-capture the filtered beads in a new droplet. With post spacing of 7 μm, beads above 10 μm had 100% capture efficiency. We demonstrate the efficacy of this system using targeted particles that bind onto the functionalized beads and are, therefore, transferred from one solution to another in the device. Binding capacity tests performed in the bulk phase showed an average binding capacity of 5 particles to each bead. The microfluidic device successfully separated the targeted particles from the non-targeted particles with up to 98% purity and 100% yield.
Collapse
Affiliation(s)
- Sida Wang
- Department of Chemical Engineering, University of Michigan–Ann Arbor, Ann Arbor, MI, United States of America
| | - Ki-Joo Sung
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Xiaoxia Nina Lin
- Department of Chemical Engineering, University of Michigan–Ann Arbor, Ann Arbor, MI, United States of America
- Department of Biomedical Engineering, University of Michigan–Ann Arbor, Ann Arbor, MI, United States of America
| | - Mark A. Burns
- Department of Chemical Engineering, University of Michigan–Ann Arbor, Ann Arbor, MI, United States of America
- Department of Biomedical Engineering, University of Michigan–Ann Arbor, Ann Arbor, MI, United States of America
| |
Collapse
|
22
|
Tang MYH, Shum HC. One-step immunoassay of C-reactive protein using droplet microfluidics. LAB ON A CHIP 2016; 16:4359-4365. [PMID: 27738692 DOI: 10.1039/c6lc01121g] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
We present a wash-free high-sensitivity immunoassay of C-reactive proteins with droplet microfluidics. Microbeads are encapsulated within droplets for the immunoassay, and the droplets are scanned by a fluorescence detection platform to quantify the amount of proteins captured on the microbeads. The limit of detection determined by our platform is 0.01 μg mL-1, which is ten times more sensitive than conventional high-sensitivity C-reactive protein assays. With the decrease in diffusion distance within droplets, the immunoassay requires only half of the time required for similar conventional approaches. This approach for carrying out immunoassays can potentially be applied to other biomarkers beyond C-reactive proteins.
Collapse
Affiliation(s)
- Matthew Y H Tang
- Department of Mechanical Engineering, University of Hong Kong, Pokfulam Road, Hong Kong, China.
| | - Ho Cheung Shum
- Department of Mechanical Engineering, University of Hong Kong, Pokfulam Road, Hong Kong, China. and HKU-Shenzhen Institute of Research and Innovation (HKU-SIRI), Shenzhen, Guangdong 518000, China.
| |
Collapse
|
23
|
Armbrecht L, Dincer C, Kling A, Horak J, Kieninger J, Urban G. Self-assembled magnetic bead chains for sensitivity enhancement of microfluidic electrochemical biosensor platforms. LAB ON A CHIP 2015; 15:4314-4321. [PMID: 26394820 DOI: 10.1039/c5lc00796h] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In this paper, we present a novel approach to enhance the sensitivity of microfluidic biosensor platforms with self-assembled magnetic bead chains. An adjustable, more than 5-fold sensitivity enhancement is achieved by introducing a magnetic field gradient along a microfluidic channel by means of a soft-magnetic lattice with a 350 μm spacing. The alternating magnetic field induces the self-assembly of the magnetic beads in chains or clusters and thus improves the perfusion and active contact between the analyte and the beads. The soft-magnetic lattices can be applied independent of the channel geometry or chip material to any microfluidic biosensing platform. At the same time, the bead-based approach achieves chip reusability and shortened measurement times. The bead chain properties and the maximum flow velocity for bead retention were validated by optical microscopy in a glass capillary. The magnetic actuation system was successfully validated with a biotin-streptavidin model assay on a low-cost electrochemical microfluidic chip, fabricated by dry-film photoresist technology (DFR). Labelling with glucose oxidase (GOx) permits rapid electrochemical detection of enzymatically produced H2O2.
Collapse
Affiliation(s)
- L Armbrecht
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, 79110 Freiburg, Germany.
| | - C Dincer
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, 79110 Freiburg, Germany. and Freiburg Materials Research Center - FMF, University of Freiburg, 79110 Freiburg, Germany
| | - A Kling
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, 79110 Freiburg, Germany.
| | - J Horak
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, 79110 Freiburg, Germany. and Division of Chemical Protein Engineering, KTH Stockholm, Stockholm, Sweden
| | - J Kieninger
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, 79110 Freiburg, Germany.
| | - G Urban
- Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, 79110 Freiburg, Germany. and Freiburg Materials Research Center - FMF, University of Freiburg, 79110 Freiburg, Germany
| |
Collapse
|
24
|
Lee H, Xu L, Oh KW. Droplet-based microfluidic washing module for magnetic particle-based assays. BIOMICROFLUIDICS 2014; 8:044113. [PMID: 25379098 PMCID: PMC4189219 DOI: 10.1063/1.4892495] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Accepted: 07/28/2014] [Indexed: 05/06/2023]
Abstract
In this paper, we propose a continuous flow droplet-based microfluidic platform for magnetic particle-based assays by employing in-droplet washing. The droplet-based washing was implemented by traversing functionalized magnetic particles across a laterally merged droplet from one side (containing sample and reagent) to the other (containing buffer) by an external magnetic field. Consequently, the magnetic particles were extracted to a parallel-synchronized train of washing buffer droplets, and unbound reagents were left in an original train of sample droplets. To realize the droplet-based washing function, the following four procedures were sequentially carried in a droplet-based microfluidic device: parallel synchronization of two trains of droplets by using a ladder-like channel network; lateral electrocoalescence by an electric field; magnetic particle manipulation by a magnetic field; and asymmetrical splitting of merged droplets. For the stable droplet synchronization and electrocoalescence, we optimized droplet generation conditions by varying the flow rate ratio (or droplet size). Image analysis was carried out to determine the fluorescent intensity of reagents before and after the washing step. As a result, the unbound reagents in sample droplets were significantly removed by more than a factor of 25 in the single washing step, while the magnetic particles were successfully extracted into washing buffer droplets. As a proof-of-principle, we demonstrate a magnetic particle-based immunoassay with streptavidin-coated magnetic particles and fluorescently labelled biotin in the proposed continuous flow droplet-based microfluidic platform.
Collapse
Affiliation(s)
- Hun Lee
- SMALL (Sensors and MicroActuators Learning Lab), Department of Electrical Engineering, The State University of New York at Buffalo , Buffalo, New York 14260, USA
| | - Linfeng Xu
- SMALL (Sensors and MicroActuators Learning Lab), Department of Electrical Engineering, The State University of New York at Buffalo , Buffalo, New York 14260, USA
| | - Kwang W Oh
- SMALL (Sensors and MicroActuators Learning Lab), Department of Electrical Engineering, The State University of New York at Buffalo , Buffalo, New York 14260, USA
| |
Collapse
|