1
|
Gupta S, Russell B, Kristensen LG, Tyler J, Costello SM, Marqusee S, Rad B, Ralston CY. Enabling simultaneous photoluminescence spectroscopy and X-ray footprinting mass spectrometry to study protein conformation and interactions. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2025; 17:1214-1225. [PMID: 39749913 PMCID: PMC11802294 DOI: 10.1039/d4ay01670j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
Abstract
X-ray footprinting mass spectrometry (XFMS) is a structural biology method that uses broadband X-rays for in situ hydroxyl radical labeling to map protein interactions and conformation in solution. However, while XFMS alone provides important structural information on biomolecules, as we move into the era of the interactome, hybrid methods are becoming increasingly necessary to gain a comprehensive understanding of protein complexes and interactions. Toward this end, we report the development of the first synergetic application of inline and real-time fluorescent spectroscopy at the Advanced Light Source's XFMS facility to study local protein interactions and global conformational changes simultaneously. To facilitate general use, we designed a flexible and optimum system for producing high-quality spectroscopy-XFMS hybrid data, with rapid interchangeable liquid jet or capillary sample delivery for multimodal inline spectroscopy, and several choices for optofluidic environments. To validate the hybrid system, we used the covalently interacting SpyCatcher-SpyTag split protein system. We show that our hybrid system can be used to detect the interaction of SpyTag and SpyCatcher via fluorescence resonance energy transfer (FRET), while elucidating key structural features throughout the complex at the residue level via XFMS. Our results highlight the usefulness of hybrid method in providing binding and structural details to precisely engineer protein interactions.
Collapse
Affiliation(s)
- Sayan Gupta
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - Brandon Russell
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - Line G Kristensen
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - James Tyler
- Molecular Foundry Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA.
| | - Shawn M Costello
- Department of Molecular and Cell Biology, University of California at Berkeley, Berkeley, California 94720, USA
| | - Susan Marqusee
- Department of Molecular and Cell Biology, University of California at Berkeley, Berkeley, California 94720, USA
| | - Behzad Rad
- Molecular Foundry Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA.
| | - Corie Y Ralston
- Molecular Foundry Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA.
| |
Collapse
|
2
|
Rose JB, Gascón JA, Sutter M, Sheppard DI, Kerfeld CA, Beck WF. Photoactivation of the orange carotenoid protein requires two light-driven reactions mediated by a metastable monomeric intermediate. Phys Chem Chem Phys 2023; 25:33000-33012. [PMID: 38032096 DOI: 10.1039/d3cp04484j] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023]
Abstract
The orange carotenoid protein (OCP) functions as a sensor of the ambient light intensity and as a quencher of bilin excitons when it binds to the core of the cyanobacterial phycobilisome. We show herein that the photoactivation mechanism that converts the resting, orange-colored state, OCPO, to the active red-colored state, OCPR, requires a sequence of two reactions, each requiring absorption of a single photon by an intrinsic ketocarotenoid chromophore. Global analysis of absorption spectra recorded during continuous illumination of OCPO preparations from Synechocystis sp. PCC 6803 detects the reversible formation of a metastable intermediate, OCPI, in which the ketocarotenoid canthaxanthin exhibits an absorption spectrum with a partial red shift and a broadened vibronic structure compared to that of the OCPO state. While the dark recovery from OCPR to OCPI is a first-order, unimolecular reaction, the subsequent conversion of OCPI to the resting OCPO state is bimolecular, involving association of two OCPO monomers to form the dark-stable OCPO dimer aggregate. These results indicate that photodissociation of the OCPO dimer to form the monomeric OCPO intermediate is the first step in the photoactivation mechanism. Formation of the OCPO monomer from the dimer increases the mean value and broadens the distribution of the solvent-accessible surface area of the canthaxanthin chromophore measured in molecular dynamics trajectories at 300 K. The second step in the photoactivation mechanism is initiated by absorption of a second photon, by canthaxanthin in the OCPO monomer, which obtains the fully red-shifted and broadened absorption spectrum detected in the OCPR product state owing to displacement of the C-terminal domain and the translocation of canthaxanthin more than 12 Å into the N-terminal domain. Both steps in the photoactivation reaction of OCP are likely to involve changes in the structure of the C-terminal domain elicited by excited-state conformational motions of the ketocarotenoid.
Collapse
Affiliation(s)
- Justin B Rose
- Department of Chemistry, Michigan State University, East Lansing, Michigan 48824-1322, USA.
| | - José A Gascón
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, USA
| | - Markus Sutter
- MSU-DOE Plant Research Laboratory, Michigan State University, East Lansing, Michigan 48824-1322, USA
- Environmental Genomics and Systems Biology Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - Damien I Sheppard
- MSU-DOE Plant Research Laboratory, Michigan State University, East Lansing, Michigan 48824-1322, USA
| | - Cheryl A Kerfeld
- MSU-DOE Plant Research Laboratory, Michigan State University, East Lansing, Michigan 48824-1322, USA
- Environmental Genomics and Systems Biology Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
| | - Warren F Beck
- Department of Chemistry, Michigan State University, East Lansing, Michigan 48824-1322, USA.
| |
Collapse
|
3
|
Arcidiacono A, Accomasso D, Cupellini L, Mennucci B. How orange carotenoid protein controls the excited state dynamics of canthaxanthin. Chem Sci 2023; 14:11158-11169. [PMID: 37860660 PMCID: PMC10583711 DOI: 10.1039/d3sc02662k] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 09/21/2023] [Indexed: 10/21/2023] Open
Abstract
Orange Carotenoid Protein (OCP) is a ketocarotenoid-binding protein essential for photoprotection in cyanobacteria. The main steps of the photoactivated conversion which converts OCP from its resting state to the active one have been extensively investigated. However, the initial photochemical event in the ketocarotenoid which triggers the large structural changes finally leading to the active state is still not understood. Here we employ QM/MM surface hopping nonadiabatic dynamics to investigate the excited-state decay of canthaxanthin in OCP, both in the ultrafast S2 to S1 internal conversion and the slower decay leading back to the ground state. For the former step we show the involvement of an additional excited state, which in the literature has been often named the SX state, and we characterize its nature. For the latter step, we reveal an excited state decay characterized by multiple timescales, which are related to the ground-state conformational heterogeneity of the ketocarotenoid. We assigned the slowly decaying population to the so-called S* state. Finally, we identify a minor decay pathway involving double-bond photoisomerization, which could be the initial trigger to photoactivation of OCP.
Collapse
Affiliation(s)
- Amanda Arcidiacono
- Dipartimento di Chimica e Chimica Industriale, Università di Pisa Via G. Moruzzi 13 56124 Pisa Italy
| | - Davide Accomasso
- Dipartimento di Chimica e Chimica Industriale, Università di Pisa Via G. Moruzzi 13 56124 Pisa Italy
| | - Lorenzo Cupellini
- Dipartimento di Chimica e Chimica Industriale, Università di Pisa Via G. Moruzzi 13 56124 Pisa Italy
| | - Benedetta Mennucci
- Dipartimento di Chimica e Chimica Industriale, Università di Pisa Via G. Moruzzi 13 56124 Pisa Italy
| |
Collapse
|
4
|
Planinc I, Ilic I, Dejea H, Garcia-Canadilla P, Gasparovic H, Jurin H, Milicic D, Skoric B, Stampanoni M, Bijnens B, Bonnin A, Cikes M. A Novel Three-Dimensional Approach Towards Evaluating Endomyocardial Biopsies for Follow-Up After Heart Transplantation: X-Ray Phase Contrast Imaging and Its Agreement With Classical Histopathology. Transpl Int 2023; 36:11046. [PMID: 36762268 PMCID: PMC9904361 DOI: 10.3389/ti.2023.11046] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 01/09/2023] [Indexed: 01/26/2023]
Abstract
Endomyocardial biopsies are the gold standard for surveillance of graft rejection following heart transplantation, and are assessed by classical histopathology using a limited number of previously stained slices from several biopsies. Synchrotron propagation-based X-ray phase contrast imaging is a non-destructive method to image biological samples without tissue preparation, enabling virtual 2D and 3D histopathology. We aimed to show the feasibility of this method to assess acute cellular rejection and its agreement to classical histopathology. Right ventricular biopsies were sampled from 23 heart transplantation recipients (20 males, mean age 54±14 years) as part of standard follow-up. The clinical diagnosis of potential rejection was made using classical histopathology. One additional study sample was harvested and imaged by X-ray phase contrast imaging, producing 3D datasets with 0.65 μm pixel size, and up to 4,320 images per sample. An experienced pathologist graded both histopathological and X-ray phase contrast images in a blinded fashion. The agreement between methods was assessed by weighted kappa, showing substantial agreement (kappa up to 0.80, p < 0.01) between X-ray phase contrast imaging and classical histopathology. X-ray phase contrast imaging does not require tissue processing, allows thorough analysis of a full myocardial sample and allows identification of acute cellular rejection.
Collapse
Affiliation(s)
- Ivo Planinc
- Department of Cardiovascular Diseases, University Hospital Centre Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Ivana Ilic
- Department of Pathology and Cytology, University Hospital Centre Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Hector Dejea
- Paul Scherrer Institute (PSI), Villigen, Switzerland,Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Patricia Garcia-Canadilla
- Institut de Recerca Biomèdica August Pi i Sunyer (IDIBAPS), Barcelona, Spain,BCNatal-Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Sant Joan de Déu and Hospital Clínic, University of Barcelona, Barcelona, Spain,Cardiovascular Diseases and Child Development, Institut de Recerca Sant Joan de Déu, Esplugues de Llobregat, Spain
| | - Hrvoje Gasparovic
- Department of Cardiac Surgery, University Hospital Centre Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Hrvoje Jurin
- Department of Cardiovascular Diseases, University Hospital Centre Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Davor Milicic
- Department of Cardiovascular Diseases, University Hospital Centre Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Bosko Skoric
- Department of Cardiovascular Diseases, University Hospital Centre Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Marco Stampanoni
- Paul Scherrer Institute (PSI), Villigen, Switzerland,Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Bart Bijnens
- Institut de Recerca Biomèdica August Pi i Sunyer (IDIBAPS), Barcelona, Spain,Catalan Institution for Research and Advanced Studies (ICREA), Barcelona, Spain
| | - Anne Bonnin
- Paul Scherrer Institute (PSI), Villigen, Switzerland
| | - Maja Cikes
- Department of Cardiovascular Diseases, University Hospital Centre Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia,*Correspondence: Maja Cikes,
| |
Collapse
|
5
|
Xue L, Li Z, Si S, Luo H, He Y. Characterization of the error of the speckle-based wavefront metrology device at Shanghai Synchrotron Radiation Facility. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:013105. [PMID: 36725610 DOI: 10.1063/5.0116933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Accepted: 11/26/2022] [Indexed: 06/18/2023]
Abstract
A metrology device based on the near-field speckle technique was developed in the x-ray test beamline at the Shanghai Synchrotron Radiation Facility to meet the at-wavelength detection requirements of ultra-high-precision optical elements. Different sources of error that limit the uncertainty of the instrument were characterized. Two main factors that contribute to the uncertainty of the measurements were investigated: (1) noise errors introduced by the electronics and the errors introduced by the algorithm and (2) stability errors owing to environmental conditions. The results show that the high measurement stability of the device is realized because it is insensitive to the effect of the external environment. The repetition accuracy of the device achieved 9 nrad (rms) when measuring the planar mirror that produces weak phase curvature.
Collapse
Affiliation(s)
- Lian Xue
- Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, China
| | - Zhongliang Li
- Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, China
| | - Shangyu Si
- Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, China
| | - Hongxin Luo
- Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, China
| | - Yumei He
- Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, China
| |
Collapse
|
6
|
Ma Y, Liu D, Hua J, Lu W. Dual-energy micro-focus computed tomography based on the energy-angle correlation of inverse Compton scattering source. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2023; 31:1227-1243. [PMID: 37638471 DOI: 10.3233/xst-230093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/29/2023]
Abstract
BACKGROUND Inverse Compton scattering (ICS) source can produce quasi-monoenergetic micro-focus X-rays ranging from keV to MeV level, with potential applications in the field of high-resolution computed tomography (CT) imaging. ICS source has an energy-angle correlated feature that lower photon energy is obtained at larger emission angle, thus different photon energies are inherently contained in each ICS pulse, which is especially advantageous for dual- or multi-energy CT imaging. OBJECTIVE This study proposes a dual-energy micro-focus CT scheme based on the energy-angle correlation of ICS source and tests its function using numerical simulations. METHODS In this scheme, high- and low-energy regions are chosen over the angular direction of each ICS pulse, and dual-energy projections of the object are obtained by an angularly-splicing scanning method. The field-of-view (FOV) of ICS source is extended simultaneously through this scanning method, thus the scale of the imaging system can be efficiently reduced. A dedicated dual-energy CT algorithm is developed to reconstruct the monoenergetic attenuation coefficients, electron density, and effective atomic number distributions of the object. RESULTS A test object composed of different materials (carbon, aluminium, titanium, iron and copper) and line pairs with different widths (15/24/39/60 μm) is imaged by the proposed dual-energy CT scheme using numerical simulations, and high-fidelity monoenergetic attenuation coefficient, electron density, and effective atomic number distributions are obtained. All the line pairs are well identified, and the contrast ratio of the 15 μm lines is 22%, showing good accordance with the theoretical predictions. CONCLUSIONS The proposed dual-energy CT scheme can reconstruct fine inner structures and material compositions of the object simultaneously, opening a new possibility for the application of ICS source in the field of non-destructive testing.
Collapse
Affiliation(s)
- Yue Ma
- Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
- Department of Engineering Physics, Tsinghua University, Beijing, China
| | - Dexiang Liu
- Department of Engineering Physics, Tsinghua University, Beijing, China
| | - Jianfei Hua
- Department of Engineering Physics, Tsinghua University, Beijing, China
| | - Wei Lu
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Beijing Academy of Quantum Information Sciences, Beijing, China
| |
Collapse
|
7
|
Higashi Y, Ma Y, Matsumoto K, Shiro A, Saitoh H, Kawachi T, Tamanoi F. Auger electrons and DNA double-strand breaks studied by using iodine-containing chemicals. Enzymes 2022; 51:101-115. [PMID: 36336404 DOI: 10.1016/bs.enz.2022.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Irradiation of high Z elements such as iodine, gold, gadolinium with monochromatic X-rays causes photoelectric effects that include the release of Auger electrons. Decay of radioactive iodine such as I-123 and I-125 also results in multiple events and some involve the generation of Auger electrons. These electrons have low energy and travel only a short distance but have a strong effect on DNA damage including the generation of double-strand breaks. In this chapter, we focus on iodine and discuss various studies that used iodine-containing chemicals to generate Auger electrons and cause DNA double-strand breaks. First, DNA synthesis precursors containing iodine were used to place iodine on DNA. DNA binding dyes such as iodine Hoechst were investigated for Auger electron generation and DNA breaks. More recently, iodine containing nanoparticles were developed. We describe our study using tumor spheroids loaded with iodine nanoparticles and synchrotron-generated monochromatic X-rays. This study led to the demonstration that an optimum effect on DNA double-strand break formation is observed with a 33.2keV X-ray which is just above the K-edge energy of iodine.
Collapse
Affiliation(s)
- Yuya Higashi
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan
| | - Yue Ma
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan; Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China
| | - Kotaro Matsumoto
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan
| | - Ayumi Shiro
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum Science and Technology, Hyogo, Japan
| | - Hiroyuki Saitoh
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum Science and Technology, Hyogo, Japan
| | - Tetsuya Kawachi
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institute for Quantum Science and Technology, Kizu, Japan
| | - Fuyuhiko Tamanoi
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan
| |
Collapse
|
8
|
Structures of a phycobilisome in light-harvesting and photoprotected states. Nature 2022; 609:835-845. [PMID: 36045294 DOI: 10.1038/s41586-022-05156-4] [Citation(s) in RCA: 79] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 07/27/2022] [Indexed: 11/08/2022]
Abstract
Phycobilisome (PBS) structures are elaborate antennae in cyanobacteria and red algae1,2. These large protein complexes capture incident sunlight and transfer the energy through a network of embedded pigment molecules called bilins to the photosynthetic reaction centres. However, light harvesting must also be balanced against the risks of photodamage. A known mode of photoprotection is mediated by orange carotenoid protein (OCP), which binds to PBS when light intensities are high to mediate photoprotective, non-photochemical quenching3-6. Here we use cryogenic electron microscopy to solve four structures of the 6.2 MDa PBS, with and without OCP bound, from the model cyanobacterium Synechocystis sp. PCC 6803. The structures contain a previously undescribed linker protein that binds to the membrane-facing side of PBS. For the unquenched PBS, the structures also reveal three different conformational states of the antenna, two previously unknown. The conformational states result from positional switching of two of the rods and may constitute a new mode of regulation of light harvesting. Only one of the three PBS conformations can bind to OCP, which suggests that not every PBS is equally susceptible to non-photochemical quenching. In the OCP-PBS complex, quenching is achieved through the binding of four 34 kDa OCPs organized as two dimers. The complex reveals the structure of the active form of OCP, in which an approximately 60 Å displacement of its regulatory carboxy terminal domain occurs. Finally, by combining our structure with spectroscopic properties7, we elucidate energy transfer pathways within PBS in both the quenched and light-harvesting states. Collectively, our results provide detailed insights into the biophysical underpinnings of the control of cyanobacterial light harvesting. The data also have implications for bioengineering PBS regulation in natural and artificial light-harvesting systems.
Collapse
|
9
|
Rosi M, Russell B, Kristensen LG, Farquhar ER, Jain R, Abel D, Sullivan M, Costello SM, Dominguez-Martin MA, Chen Y, Marqusee S, Petzold CJ, Kerfeld CA, DePonte DP, Farahmand F, Gupta S, Ralston CY. An automated liquid jet for fluorescence dosimetry and microsecond radiolytic labeling of proteins. Commun Biol 2022; 5:866. [PMID: 36008591 PMCID: PMC9411504 DOI: 10.1038/s42003-022-03775-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Accepted: 07/27/2022] [Indexed: 12/02/2022] Open
Abstract
X-ray radiolytic labeling uses broadband X-rays for in situ hydroxyl radical labeling to map protein interactions and conformation. High flux density beams are essential to overcome radical scavengers. However, conventional sample delivery environments, such as capillary flow, limit the use of a fully unattenuated focused broadband beam. An alternative is to use a liquid jet, and we have previously demonstrated that use of this form of sample delivery can increase labeling by tenfold at an unfocused X-ray source. Here we report the first use of a liquid jet for automated inline quantitative fluorescence dosage characterization and sample exposure at a high flux density microfocused synchrotron beamline. Our approach enables exposure times in single-digit microseconds while retaining a high level of side-chain labeling. This development significantly boosts the method’s overall effectiveness and efficiency, generates high-quality data, and opens up the arena for high throughput and ultrafast time-resolved in situ hydroxyl radical labeling. A high-speed liquid jet delivery system improves the X-ray footprinting and mass spectrometry method to label proteins for structural studies.
Collapse
Affiliation(s)
- Matthew Rosi
- Sonoma State University, Rohnert Park, Sonoma, CA, 94928, US
| | - Brandon Russell
- Sonoma State University, Rohnert Park, Sonoma, CA, 94928, US
| | - Line G Kristensen
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, US
| | - Erik R Farquhar
- Center for Synchrotron Biosciences, School of Medicine, Case Western Reserve University, Cleveland, OH, 44106, US
| | - Rohit Jain
- Center for Synchrotron Biosciences, School of Medicine, Case Western Reserve University, Cleveland, OH, 44106, US
| | - Donald Abel
- Center for Synchrotron Biosciences, School of Medicine, Case Western Reserve University, Cleveland, OH, 44106, US
| | - Michael Sullivan
- Center for Synchrotron Biosciences, School of Medicine, Case Western Reserve University, Cleveland, OH, 44106, US
| | - Shawn M Costello
- Biophysics Graduate Program, University of California, Berkeley, CA, USA
| | - Maria Agustina Dominguez-Martin
- MSU-DOE Plant Research Laboratory and Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, MI, 48824, US.,Environmental Genomics and Systems Biology Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, US
| | - Yan Chen
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, US
| | - Susan Marqusee
- Department of Molecular and Cell Biology, University of California, Berkeley, CA, USA.,Department of Chemistry, University of California, Berkeley, CA, USA.,California Institute for Quantitative Biosciences, University of California, Berkeley, CA, USA
| | - Christopher J Petzold
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, US
| | - Cheryl A Kerfeld
- MSU-DOE Plant Research Laboratory and Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, MI, 48824, US.,Environmental Genomics and Systems Biology Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, US
| | | | - Farid Farahmand
- Sonoma State University, Rohnert Park, Sonoma, CA, 94928, US
| | - Sayan Gupta
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, US.
| | - Corie Y Ralston
- Molecular Foundry Division, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, US.
| |
Collapse
|
10
|
Eckermann M, van der Meer F, Cloetens P, Ruhwedel T, Möbius W, Stadelmann C, Salditt T. Three-dimensional virtual histology of the cerebral cortex based on phase-contrast X-ray tomography. BIOMEDICAL OPTICS EXPRESS 2021; 12:7582-7598. [PMID: 35003854 PMCID: PMC8713656 DOI: 10.1364/boe.434885] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 10/05/2021] [Accepted: 10/06/2021] [Indexed: 05/09/2023]
Abstract
In this work, we optimize the setups and experimental parameters of X-ray phase-contrast computed-tomography for the three-dimensional imaging of the cyto- and myeloarchitecture of cerebral cortex, including both human and murine tissue. We present examples for different optical configurations using state-of-the art synchrotron instruments for holographic tomography, as well as compact laboratory setups for phase-contrast tomography in the direct contrast (edge-enhancement) regime. Apart from unstained and paraffin-embedded tissue, we tested hydrated tissue, as well as heavy metal stained and resin-embedded tissue using two different protocols. Further, we show that the image quality achieved allows to assess the neuropathology of multiple sclerosis in a biopsy sample collected during surgery.
Collapse
Affiliation(s)
- Marina Eckermann
- Institut für Röntgenphysik, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Germany
| | | | - Peter Cloetens
- ESRF, the European Synchrotron, 71, avenue des Martyrs, 38043 Grenoble Cedex 9, France
| | - Torben Ruhwedel
- Max-Planck-Institut für experimentelle Medizin, Hermann-Rein-Straße 3, 37075 Göttingen, Germany
| | - Wiebke Möbius
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Germany
- Max-Planck-Institut für experimentelle Medizin, Hermann-Rein-Straße 3, 37075 Göttingen, Germany
| | - Christine Stadelmann
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Germany
- Institut für Neuropathologie, Robert-Koch-Straße 40, 37075 Göttingen, Germany
| | - Tim Salditt
- Institut für Röntgenphysik, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Germany
| |
Collapse
|
11
|
Birnbacher L, Braig EM, Pfeiffer D, Pfeiffer F, Herzen J. Quantitative X-ray phase contrast computed tomography with grating interferometry : Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography. Eur J Nucl Med Mol Imaging 2021; 48:4171-4188. [PMID: 33846846 PMCID: PMC8566444 DOI: 10.1007/s00259-021-05259-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 02/11/2021] [Indexed: 11/25/2022]
Abstract
The ability of biomedical imaging data to be of quantitative nature is getting increasingly important with the ongoing developments in data science. In contrast to conventional attenuation-based X-ray imaging, grating-based phase contrast computed tomography (GBPC-CT) is a phase contrast micro-CT imaging technique that can provide high soft tissue contrast at high spatial resolution. While there is a variety of different phase contrast imaging techniques, GBPC-CT can be applied with laboratory X-ray sources and enables quantitative determination of electron density and effective atomic number. In this review article, we present quantitative GBPC-CT with the focus on biomedical applications.
Collapse
Affiliation(s)
- Lorenz Birnbacher
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Eva-Maria Braig
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Franz Pfeiffer
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Julia Herzen
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany.
| |
Collapse
|
12
|
He Q, Wang Y, Li P, Yao C, Zhang J, Fu T, Zhang K, Yuan Q, Huang W, Wang S, Zhu P, Liu P. Accurate reconstruction algorithm for bilateral differential phase signals. RADIATION DETECTION TECHNOLOGY AND METHODS 2021. [DOI: 10.1007/s41605-021-00273-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
13
|
Clark D, Badea C. Advances in micro-CT imaging of small animals. Phys Med 2021; 88:175-192. [PMID: 34284331 PMCID: PMC8447222 DOI: 10.1016/j.ejmp.2021.07.005] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 06/23/2021] [Accepted: 07/05/2021] [Indexed: 12/22/2022] Open
Abstract
PURPOSE Micron-scale computed tomography (micro-CT) imaging is a ubiquitous, cost-effective, and non-invasive three-dimensional imaging modality. We review recent developments and applications of micro-CT for preclinical research. METHODS Based on a comprehensive review of recent micro-CT literature, we summarize features of state-of-the-art hardware and ongoing challenges and promising research directions in the field. RESULTS Representative features of commercially available micro-CT scanners and some new applications for both in vivo and ex vivo imaging are described. New advancements include spectral scanning using dual-energy micro-CT based on energy-integrating detectors or a new generation of photon-counting x-ray detectors (PCDs). Beyond two-material discrimination, PCDs enable quantitative differentiation of intrinsic tissues from one or more extrinsic contrast agents. When these extrinsic contrast agents are incorporated into a nanoparticle platform (e.g. liposomes), novel micro-CT imaging applications are possible such as combined therapy and diagnostic imaging in the field of cancer theranostics. Another major area of research in micro-CT is in x-ray phase contrast (XPC) imaging. XPC imaging opens CT to many new imaging applications because phase changes are more sensitive to density variations in soft tissues than standard absorption imaging. We further review the impact of deep learning on micro-CT. We feature several recent works which have successfully applied deep learning to micro-CT data, and we outline several challenges specific to micro-CT. CONCLUSIONS All of these advancements establish micro-CT imaging at the forefront of preclinical research, able to provide anatomical, functional, and even molecular information while serving as a testbench for translational research.
Collapse
Affiliation(s)
- D.P. Clark
- Quantitative Imaging and Analysis Lab, Department of Radiology, Duke University Medical Center, Durham, NC 27710
| | - C.T. Badea
- Quantitative Imaging and Analysis Lab, Department of Radiology, Duke University Medical Center, Durham, NC 27710
| |
Collapse
|
14
|
Iodine containing porous organosilica nanoparticles trigger tumor spheroids destruction upon monochromatic X-ray irradiation: DNA breaks and K-edge energy X-ray. Sci Rep 2021; 11:14192. [PMID: 34262055 PMCID: PMC8280225 DOI: 10.1038/s41598-021-93429-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 06/17/2021] [Indexed: 02/06/2023] Open
Abstract
X-ray irradiation of high Z elements causes photoelectric effects that include the release of Auger electrons that can induce localized DNA breaks. We have previously established a tumor spheroid-based assay that used gadolinium containing mesoporous silica nanoparticles and synchrotron-generated monochromatic X-rays. In this work, we focused on iodine and synthesized iodine-containing porous organosilica (IPO) nanoparticles. IPO were loaded onto tumor spheroids and the spheroids were irradiated with 33.2 keV monochromatic X-ray. After incubation in CO2 incubator, destruction of tumor spheroids was observed which was accompanied by apoptosis induction, as determined by the TUNEL assay. By employing the γH2AX assay, we detected double strand DNA cleavages immediately after the irradiation. These results suggest that IPO first generate double strand DNA breaks upon X-ray irradiation followed by apoptosis induction of cancer cells. Use of three different monochromatic X-rays having energy levels of 33.0, 33.2 and 33.4 keV as well as X-rays with 0.1 keV energy intervals showed that the optimum effect of all three events (spheroid destruction, apoptosis induction and generation of double strand DNA breaks) occurred with a 33.2 keV monochromatic X-ray. These results uncover the preferential effect of K-edge energy X-ray for tumor spheroid destruction mediated by iodine containing nanoparticles.
Collapse
|
15
|
Comprehensive assessment of myocardial remodeling in ischemic heart disease by synchrotron propagation based X-ray phase contrast imaging. Sci Rep 2021; 11:14020. [PMID: 34234175 PMCID: PMC8263575 DOI: 10.1038/s41598-021-93054-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 06/16/2021] [Indexed: 02/06/2023] Open
Abstract
Cardiovascular research is in an ongoing quest for a superior imaging method to integrate gross-anatomical information with microanatomy, combined with quantifiable parameters of cardiac structure. In recent years, synchrotron radiation-based X-ray Phase Contrast Imaging (X-PCI) has been extensively used to characterize soft tissue in detail. The objective was to use X-PCI to comprehensively quantify ischemic remodeling of different myocardial structures, from cell to organ level, in a rat model of myocardial infarction. Myocardial infarction-induced remodeling was recreated in a well-established rodent model. Ex vivo rodent hearts were imaged by propagation based X-PCI using two configurations resulting in 5.8 µm and 0.65 µm effective pixel size images. The acquired datasets were used for a comprehensive assessment of macrostructural changes including the whole heart and vascular tree morphology, and quantification of left ventricular myocardial thickness, mass, volume, and organization. On the meso-scale, tissue characteristics were explored and compared with histopathological methods, while microstructural changes were quantified by segmentation of cardiomyocytes and calculation of cross-sectional areas. Propagation based X-PCI provides detailed visualization and quantification of morphological changes on whole organ, tissue, vascular as well as individual cellular level of the ex vivo heart, with a single, non-destructive 3D imaging modality.
Collapse
|
16
|
Horng A, Stroebel J, Geith T, Milz S, Pacureanu A, Yang Y, Cloetens P, Lovric G, Mittone A, Bravin A, Coan P. Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation. J Biomed Sci 2021; 28:42. [PMID: 34098949 PMCID: PMC8182937 DOI: 10.1186/s12929-021-00739-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Accepted: 06/01/2021] [Indexed: 12/14/2022] Open
Abstract
Background The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Methods Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm3. Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. Results X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. Conclusions X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.
Collapse
Affiliation(s)
- Annie Horng
- Department of Clinical Radiology, Faculty of Medicine, Ludwig-Maximilians-University, Marchioninistr. 15, 81377, Munich, Germany.,RZM - Radiologisches Zentrum Munich-Pasing, Pippinger Str. 25, 81245, Munich, Germany
| | - Johannes Stroebel
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-University Munich, Am Coulombwall 1, 85748, Garching, Germany
| | - Tobias Geith
- Department of Interventional Radiology, Klinikum Rechts der Isar of the Technical University of Munich, Munich, Germany
| | - Stefan Milz
- Faculty of Medicine, Anatomische Anstalt, Neuroanatomy, Ludwig Maximilians University, Munich, Germany
| | | | - Yang Yang
- European Synchrotron Radiation Facility, Grenoble, France.,National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY, 11973, USA
| | - Peter Cloetens
- European Synchrotron Radiation Facility, Grenoble, France
| | - Goran Lovric
- Paul Scherrer Institute (Swiss Light Source), Villigen, Switzerland
| | | | - Alberto Bravin
- European Synchrotron Radiation Facility, Grenoble, France
| | - Paola Coan
- Department of Clinical Radiology, Faculty of Medicine, Ludwig-Maximilians-University, Marchioninistr. 15, 81377, Munich, Germany. .,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-University Munich, Am Coulombwall 1, 85748, Garching, Germany.
| |
Collapse
|
17
|
Loncaric F, Garcia-Canadilla P, Garcia-Alvarez A, Sanchis L, Prat S, Doltra A, Quintana E, Pereda D, Dejea H, Bonnin A, Sitges M, Bijnens B. Etiology-Discriminative Multimodal Imaging of Left Ventricular Hypertrophy and Synchrotron-Based Assessment of Microstructural Tissue Remodeling. Front Cardiovasc Med 2021; 8:670734. [PMID: 34113664 PMCID: PMC8185228 DOI: 10.3389/fcvm.2021.670734] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Accepted: 04/07/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Distinguishing the etiology of left ventricular hypertrophy (LVH) is clinically relevant due to patient outcomes and management. Easily obtained, echocardiography-based myocardial deformation patterns may improve standard non-invasive phenotyping, however, the relationship between deformation phenotypes and etiology-related, microstructural cardiac remodeling has not been reported. Synchrotron radiation-based X-ray phase-contrast imaging (X-PCI) can provide high resolution, three-dimensional (3D) information on myocardial microstructure. The aim of this pilot study is to apply a multiscale, multimodality protocol in LVH patients undergoing septal myectomy to visualize in vivo and ex vivo myocardial tissue and relate non-invasive LVH imaging phenotypes to the underlying synchrotron-assessed microstructure. Methods and findings: Three patients (P1-3) undergoing septal myectomy were comprehensively studied. Medical history was collected, and patients were imaged with echocardiography/cardiac magnetic resonance prior to the procedure. Myocardial tissue samples obtained during the myectomy were imaged with X-PCI generating high spatial resolution images (0.65 μm) to assess myocyte organization, 3D connective tissue distribution and vasculature remodeling. Etiology-centered non-invasive imaging phenotypes, based on findings of hypertrophy and late gadolinium enhancement (LGE) distribution, and enriched by speckle-tracking and tissue Doppler echocardiography deformation patterns, identified a clear phenotype of hypertensive heart disease (HTN) in P1, and hypertrophic cardiomyopathy (HCM) in P2/P3. X-PCI showed extensive interstitial fibrosis with normal 3D myocyte and collagen organization in P1. In comparison, in P2/P3, X-PCI showed 3D myocyte and collagen disarray, as well as arterial wall hypertrophy with increased perivascular collagen, compatible with sarcomere-mutation HCM in both patients. The results of this pilot study suggest the association of non-invasive deformation phenotypes with etiology-related myocyte and connective tissue matrix disorganization. A larger patient cohort could enable statistical analysis of group characteristics and the assessment of deformation pattern reproducibility. Conclusion: High-resolution, 3D X-PCI provides novel ways to visualize myocardial remodeling in LVH, and illustrates the correspondence of macrostructural and functional non-invasive phenotypes with invasive microstructural phenotypes, suggesting the potential clinical utility of non-invasive myocardial deformation patterns in phenotyping LVH in everyday clinical practice.
Collapse
Affiliation(s)
- Filip Loncaric
- Institut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain
| | | | - Ana Garcia-Alvarez
- Institut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain
- Cardiovascular Institute, Hospital Clínic and Universitat de Barcelona, Barcelona, Spain
| | - Laura Sanchis
- Cardiovascular Institute, Hospital Clínic and Universitat de Barcelona, Barcelona, Spain
| | - Susana Prat
- Cardiovascular Institute, Hospital Clínic and Universitat de Barcelona, Barcelona, Spain
| | - Adelina Doltra
- Cardiovascular Institute, Hospital Clínic and Universitat de Barcelona, Barcelona, Spain
| | - Eduard Quintana
- Cardiovascular Institute, Hospital Clínic and Universitat de Barcelona, Barcelona, Spain
| | - Daniel Pereda
- Cardiovascular Institute, Hospital Clínic and Universitat de Barcelona, Barcelona, Spain
| | - Hector Dejea
- Photon Science Department, Paul Scherrer Institut, Villigen, Switzerland
- Eidgenössische Technische Hochschule Zurich, Zurich, Switzerland
| | - Anne Bonnin
- Photon Science Department, Paul Scherrer Institut, Villigen, Switzerland
| | - Marta Sitges
- Institut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain
- Cardiovascular Institute, Hospital Clínic and Universitat de Barcelona, Barcelona, Spain
- Centro de Investigación en Red de Enfermedades Cardiovasculares (CERCA), Madrid, Spain
| | - Bart Bijnens
- Institut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain
- Institució Catalana de Recerca i Estudis Avançats, Barcelona, Spain
| |
Collapse
|
18
|
Sanchez-Cano C, Alvarez-Puebla RA, Abendroth JM, Beck T, Blick R, Cao Y, Caruso F, Chakraborty I, Chapman HN, Chen C, Cohen BE, Conceição ALC, Cormode DP, Cui D, Dawson KA, Falkenberg G, Fan C, Feliu N, Gao M, Gargioni E, Glüer CC, Grüner F, Hassan M, Hu Y, Huang Y, Huber S, Huse N, Kang Y, Khademhosseini A, Keller TF, Körnig C, Kotov NA, Koziej D, Liang XJ, Liu B, Liu S, Liu Y, Liu Z, Liz-Marzán LM, Ma X, Machicote A, Maison W, Mancuso AP, Megahed S, Nickel B, Otto F, Palencia C, Pascarelli S, Pearson A, Peñate-Medina O, Qi B, Rädler J, Richardson JJ, Rosenhahn A, Rothkamm K, Rübhausen M, Sanyal MK, Schaak RE, Schlemmer HP, Schmidt M, Schmutzler O, Schotten T, Schulz F, Sood AK, Spiers KM, Staufer T, Stemer DM, Stierle A, Sun X, Tsakanova G, Weiss PS, Weller H, Westermeier F, Xu M, Yan H, Zeng Y, Zhao Y, Zhao Y, Zhu D, Zhu Y, Parak WJ. X-ray-Based Techniques to Study the Nano-Bio Interface. ACS NANO 2021; 15:3754-3807. [PMID: 33650433 PMCID: PMC7992135 DOI: 10.1021/acsnano.0c09563] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 01/25/2021] [Indexed: 05/03/2023]
Abstract
X-ray-based analytics are routinely applied in many fields, including physics, chemistry, materials science, and engineering. The full potential of such techniques in the life sciences and medicine, however, has not yet been fully exploited. We highlight current and upcoming advances in this direction. We describe different X-ray-based methodologies (including those performed at synchrotron light sources and X-ray free-electron lasers) and their potentials for application to investigate the nano-bio interface. The discussion is predominantly guided by asking how such methods could better help to understand and to improve nanoparticle-based drug delivery, though the concepts also apply to nano-bio interactions in general. We discuss current limitations and how they might be overcome, particularly for future use in vivo.
Collapse
Affiliation(s)
- Carlos Sanchez-Cano
- Center
for Cooperative Research in Biomaterials (CIC biomaGUNE), Basque Research and Technology Alliance (BRTA), Paseo de Miramon 182, 20014 Donostia San Sebastián, Spain
| | - Ramon A. Alvarez-Puebla
- Universitat
Rovira i Virgili, 43007 Tarragona, Spain
- ICREA, Passeig Lluís
Companys 23, 08010 Barcelona, Spain
| | - John M. Abendroth
- Department
of Materials Science and Engineering, Stanford
University, Stanford, California 94305, United States
| | - Tobias Beck
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Robert Blick
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Yuan Cao
- Department
of Chemical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Biointerfaces
Institute, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Frank Caruso
- ARC
Centre of Excellence in Convergent Bio-Nano Science and Technology
and the Department of Chemical Engineering, The University of Melbourne, Parkville, Victoria 3010, Australia
| | - Indranath Chakraborty
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Henry N. Chapman
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- Centre
for Ultrafast Imaging, Universität
Hamburg, 22761 Hamburg, Germany
- Deutsches
Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Chunying Chen
- National
Center for Nanoscience and Technology (NCNST), 100190 Beijing China
| | - Bruce E. Cohen
- The
Molecular Foundry and Division of Molecular Biophysics and Integrated
Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | | | - David P. Cormode
- Radiology
Department, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Daxiang Cui
- School
of Chemistry and Chemical Engineering, Frontiers Science Center for
Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| | | | - Gerald Falkenberg
- Deutsches
Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Chunhai Fan
- School
of Chemistry and Chemical Engineering, Frontiers Science Center for
Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Neus Feliu
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- CAN, Fraunhofer Institut, 20146 Hamburg, Germany
| | - Mingyuan Gao
- Department
of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
| | - Elisabetta Gargioni
- Department
of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
| | - Claus-C. Glüer
- Section
Biomedical Imaging, Department of Radiology and Neuroradiology, University Medical Clinic Schleswig-Holstein and Christian-Albrechts-University
Kiel, 24105 Kiel, Germany
| | - Florian Grüner
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- Universität
Hamburg and Center for Free-Electron Laser Science, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Moustapha Hassan
- Karolinska University Hospital, Huddinge, and Karolinska
Institutet, 17177 Stockholm, Sweden
| | - Yong Hu
- College of Engineering and Applied Sciences, Nanjing University, Nanjing 210093, China
| | - Yalan Huang
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Samuel Huber
- Department
of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
| | - Nils Huse
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Yanan Kang
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90049, United States
| | - Thomas F. Keller
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- Deutsches
Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Christian Körnig
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- Universität
Hamburg and Center for Free-Electron Laser Science, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Nicholas A. Kotov
- Department
of Chemical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Biointerfaces
Institute, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Michigan
Institute for Translational Nanotechnology (MITRAN), Ypsilanti, Michigan 48198, United States
| | - Dorota Koziej
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Xing-Jie Liang
- National
Center for Nanoscience and Technology (NCNST), 100190 Beijing China
| | - Beibei Liu
- Department
of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
| | - Sijin Liu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology,
Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 China
| | - Yang Liu
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Ziyao Liu
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Luis M. Liz-Marzán
- Center
for Cooperative Research in Biomaterials (CIC biomaGUNE), Basque Research and Technology Alliance (BRTA), Paseo de Miramon 182, 20014 Donostia San Sebastián, Spain
- Ikerbasque, Basque Foundation for Science, 48013 Bilbao, Spain
- Centro de Investigación Biomédica
en Red de Bioingeniería,
Biomateriales y Nanomedicina (CIBER-BBN), Paseo de Miramon 182, 20014 Donostia-San Sebastián, Spain
| | - Xiaowei Ma
- National
Center for Nanoscience and Technology (NCNST), 100190 Beijing China
| | - Andres Machicote
- Department
of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
| | - Wolfgang Maison
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Adrian P. Mancuso
- European XFEL, 22869 Schenefeld, Germany
- Department of Chemistry and Physics, La
Trobe Institute for Molecular
Science, La Trobe University, Melbourne 3086, Victoria, Australia
| | - Saad Megahed
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Bert Nickel
- Sektion Physik, Ludwig Maximilians Universität
München, 80539 München, Germany
| | - Ferdinand Otto
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Cristina Palencia
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | | | - Arwen Pearson
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Oula Peñate-Medina
- Section
Biomedical Imaging, Department of Radiology and Neuroradiology, University Medical Clinic Schleswig-Holstein and Christian-Albrechts-University
Kiel, 24105 Kiel, Germany
| | - Bing Qi
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Joachim Rädler
- Sektion Physik, Ludwig Maximilians Universität
München, 80539 München, Germany
| | - Joseph J. Richardson
- ARC
Centre of Excellence in Convergent Bio-Nano Science and Technology
and the Department of Chemical Engineering, The University of Melbourne, Parkville, Victoria 3010, Australia
| | - Axel Rosenhahn
- Department
of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
| | - Kai Rothkamm
- Department
of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
| | - Michael Rübhausen
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | | | - Raymond E. Schaak
- Department of Chemistry, Department of Chemical Engineering,
and
Materials Research Institute, The Pennsylvania
State University, University Park, Pensylvania 16802, United States
| | - Heinz-Peter Schlemmer
- Department of Radiology, German Cancer
Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Marius Schmidt
- Department of Physics, University
of Wisconsin-Milwaukee, 3135 N. Maryland Avenue, Milwaukee, Wisconsin 53211, United States
| | - Oliver Schmutzler
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- Universität
Hamburg and Center for Free-Electron Laser Science, Luruper Chaussee 149, 22761 Hamburg, Germany
| | | | - Florian Schulz
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - A. K. Sood
- Department of Physics, Indian Institute
of Science, Bangalore 560012, India
| | - Kathryn M. Spiers
- Deutsches
Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Theresa Staufer
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- Universität
Hamburg and Center for Free-Electron Laser Science, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Dominik M. Stemer
- California NanoSystems Institute, University
of California, Los Angeles, Los Angeles, California 90095, United States
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Andreas Stierle
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- Deutsches
Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Xing Sun
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- Molecular Science and Biomedicine Laboratory (MBL) State
Key Laboratory of Chemo/Biosensing and Chemometrics College of Chemistry
and Chemical Engineering, Hunan University, Changsha 410082, P.R. China
| | - Gohar Tsakanova
- Institute of Molecular Biology of National
Academy of Sciences of
Republic of Armenia, 7 Hasratyan str., 0014 Yerevan, Armenia
- CANDLE Synchrotron Research Institute, 31 Acharyan str., 0040 Yerevan, Armenia
| | - Paul S. Weiss
- California NanoSystems Institute, University
of California, Los Angeles, Los Angeles, California 90095, United States
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, California 90095, United States
- Department
of Chemistry and Biochemistry, University
of California, Los Angeles, Los Angeles, California 90095, United States
- Department of Bioengineering, University
of California, Los Angeles, Los Angeles, California 90095, United States
| | - Horst Weller
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- CAN, Fraunhofer Institut, 20146 Hamburg, Germany
| | - Fabian Westermeier
- Deutsches
Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Ming Xu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology,
Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 China
| | - Huijie Yan
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Yuan Zeng
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Ying Zhao
- Karolinska University Hospital, Huddinge, and Karolinska
Institutet, 17177 Stockholm, Sweden
| | - Yuliang Zhao
- National
Center for Nanoscience and Technology (NCNST), 100190 Beijing China
| | - Dingcheng Zhu
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
| | - Ying Zhu
- Bioimaging Center, Shanghai Synchrotron Radiation Facility,
Zhangjiang Laboratory, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China
- Division of Physical Biology, CAS Key Laboratory
of Interfacial
Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
| | - Wolfgang J. Parak
- Center
for Cooperative Research in Biomaterials (CIC biomaGUNE), Basque Research and Technology Alliance (BRTA), Paseo de Miramon 182, 20014 Donostia San Sebastián, Spain
- Mathematics,
Informatics, and Natural Sciences (MIN) Faculty, University of Hamburg, 20354 Hamburg, Germany
- School
of Chemistry and Chemical Engineering, Frontiers Science Center for
Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
19
|
Simiele EA, Breitkreutz DY, Capaldi DPI, Liu W, Bush KK, Skinner LB. Precision radiotherapy using monochromatic inverse Compton x-ray sources. Med Phys 2020; 48:366-375. [PMID: 33107049 DOI: 10.1002/mp.14552] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 09/28/2020] [Accepted: 10/02/2020] [Indexed: 11/10/2022] Open
Abstract
PURPOSE The dosimetric properties of inverse Compton (IC) x-ray sources were investigated to determine their utility for stereotactic radiation therapy. METHODS Monte Carlo simulations were performed using the egs brachy user code of EGSnrc. Nominal IC source x-ray energies of 80 and 150 keV were considered in this work. Depth-dose and lateral dose profiles in water were calculated, as was dose enhancement in the bone. Further simulations were performed for brain and spine treatment sites. The impact of gold nanoparticle doping was also investigated for the brain treatment site. Analogous dose calculations were performed in a clinical treatment planning system using a clinical 6 MV photon beam model and were compared to the Monte Carlo simulations. RESULTS Both 80 and 150 keV IC beams were observed to have sharp 80-20 penumbra (i.e., < 0.1 mm) with broad low-dose tails in water. For reference, the calculated penumbra for the 6 MV clinical beam was 3 mm. Maximum dose enhancement factors in bone of 3.1, 1.4, and 1.1 were observed for the 80, 150 keV, and clinical 6 MV beams, respectively. The plan quality for the single brain metastasis case was similar between the IC beams and the 6 MV beam without gold nanoparticles. As the concentration of gold within the target increased, the V12 Gy to the normal brain tissue and D max within the target volume significantly decreased and the conformity significantly improved, which resulted in superior plan quality over the clinical 6 MV beam plan. In the spine cases, the sharp penumbra and enhanced dose to bone of the IC beams produced superior plan quality (i.e., better conformity, normal tissue sparing, and spinal cord sparing) as compared to the clinical 6 MV beam plans. CONCLUSIONS The findings from this work indicate that inverse Compton x-ray sources are well suited for stereotactic radiotherapy treatments due to their sharp penumbra and dose enhancement around high atomic number materials. Future work includes investigating the properties of intensity-modulated inverse Compton x-ray sources to improve the homogeneity within the target tissue.
Collapse
Affiliation(s)
- Eric A Simiele
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Dylan Y Breitkreutz
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Dante P I Capaldi
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Wu Liu
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Karl K Bush
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| | - Lawrie B Skinner
- Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA
| |
Collapse
|
20
|
Günther B, Gradl R, Jud C, Eggl E, Huang J, Kulpe S, Achterhold K, Gleich B, Dierolf M, Pfeiffer F. The versatile X-ray beamline of the Munich Compact Light Source: design, instrumentation and applications. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:1395-1414. [PMID: 32876618 PMCID: PMC7467334 DOI: 10.1107/s1600577520008309] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 06/22/2020] [Indexed: 05/08/2023]
Abstract
Inverse Compton scattering provides means to generate low-divergence partially coherent quasi-monochromatic, i.e. synchrotron-like, X-ray radiation on a laboratory scale. This enables the transfer of synchrotron techniques into university or industrial environments. Here, the Munich Compact Light Source is presented, which is such a compact synchrotron radiation facility based on an inverse Compton X-ray source (ICS). The recent improvements of the ICS are reported first and then the various experimental techniques which are most suited to the ICS installed at the Technical University of Munich are reviewed. For the latter, a multipurpose X-ray application beamline with two end-stations was designed. The beamline's design and geometry are presented in detail including the different set-ups as well as the available detector options. Application examples of the classes of experiments that can be performed are summarized afterwards. Among them are dynamic in vivo respiratory imaging, propagation-based phase-contrast imaging, grating-based phase-contrast imaging, X-ray microtomography, K-edge subtraction imaging and X-ray spectroscopy. Finally, plans to upgrade the beamline in order to enhance its capabilities are discussed.
Collapse
Affiliation(s)
- Benedikt Günther
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Regine Gradl
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Christoph Jud
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Elena Eggl
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Juanjuan Huang
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Stephanie Kulpe
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Klaus Achterhold
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Bernhard Gleich
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Martin Dierolf
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Franz Pfeiffer
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Straße 22, 81675 Munich, Germany
| |
Collapse
|
21
|
Tamanoi F, Matsumoto K, Doan TLH, Shiro A, Saitoh H. Studies on the Exposure of Gadolinium Containing Nanoparticles with Monochromatic X-rays Drive Advances in Radiation Therapy. NANOMATERIALS 2020; 10:nano10071341. [PMID: 32660093 PMCID: PMC7408070 DOI: 10.3390/nano10071341] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 07/06/2020] [Accepted: 07/07/2020] [Indexed: 02/07/2023]
Abstract
While conventional radiation therapy uses white X-rays that consist of a mixture of X-ray waves with various energy levels, a monochromatic X-ray (monoenergetic X-ray) has a single energy level. Irradiation of high-Z elements such as gold, silver or gadolinium with a synchrotron-generated monochromatic X-rays with the energy at or higher than their K-edge energy causes a photoelectric effect that includes release of the Auger electrons that induce DNA damage—leading to cell killing. Delivery of high-Z elements into cancer cells and tumor mass can be facilitated by the use of nanoparticles. Various types of nanoparticles containing high-Z elements have been developed. A recent addition to this growing list of nanoparticles is mesoporous silica-based nanoparticles (MSNs) containing gadolinium (Gd–MSN). The ability of Gd–MSN to inhibit tumor growth was demonstrated by evaluating effects of irradiating tumor spheroids with a precisely tuned monochromatic X-ray.
Collapse
Affiliation(s)
- Fuyuhiko Tamanoi
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto 606-8501, Japan;
- Department of Microbio., Immunol. & Molec. Genet., University of California, Los Angeles, CA 90095, USA
- Correspondence: ; Tel.: +81-75-753-9856
| | - Kotaro Matsumoto
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto 606-8501, Japan;
| | - Tan Le Hoang Doan
- Center for Innovative Materials and Architectures (INOMAR), Vietnam National University-Ho Chi Minh City, Ho Chi Minh City 721337, Vietnam;
| | - Ayumi Shiro
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science and Technology, Hyogo 679-0198, Japan; (A.S.); (H.S.)
| | - Hiroyuki Saitoh
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science and Technology, Hyogo 679-0198, Japan; (A.S.); (H.S.)
| |
Collapse
|
22
|
Barbone GE, Bravin A, Mittone A, Kraiger MJ, Hrabě de Angelis M, Bossi M, Ballarini E, Rodriguez-Menendez V, Ceresa C, Cavaletti G, Coan P. Establishing sample-preparation protocols for X-ray phase-contrast CT of rodent spinal cords: Aldehyde fixations and osmium impregnation. J Neurosci Methods 2020; 339:108744. [DOI: 10.1016/j.jneumeth.2020.108744] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 04/14/2020] [Accepted: 04/15/2020] [Indexed: 12/14/2022]
|
23
|
Huang J, Günther B, Achterhold K, Cui YT, Gleich B, Dierolf M, Pfeiffer F. Energy-Dispersive X-ray Absorption Spectroscopy with an Inverse Compton Source. Sci Rep 2020; 10:8772. [PMID: 32472032 PMCID: PMC7260230 DOI: 10.1038/s41598-020-65225-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Accepted: 04/23/2020] [Indexed: 02/01/2023] Open
Abstract
Novel compact x-ray sources based on inverse Compton scattering can generate brilliant hard x-rays in a laboratory setting. Their collimated intense beams with tunable well-defined x-ray energies make them well suited for x-ray spectroscopy techniques, which are typically carried out at large facilities. Here, we demonstrate a first x-ray absorption spectroscopy proof-of-principle experiment using an inverse Compton x-ray source with a flux of >1010 photons/s in <5% bandwidth. We measured x-ray absorption near edge structure and extended x-ray absorption fine structure at the silver K-edge (~25.5 keV) for a series of silver samples. We propose an energy-dispersive geometry specifically adapted to the x-ray beam properties of inverse Compton x-ray sources together with a fast concentration correction method that corrects sample inhomogeneities very effectively. The combination of our setup with the inverse Compton source generates x-ray absorption spectra with high energy resolution in exposure times down to one minute. Our results unravel the great benefit of inverse Compton scattering sources for x-ray absorption techniques in a laboratory environment, especially in the hard x-ray regime, which allows to probe absorption edges of high Z materials.
Collapse
Affiliation(s)
- Juanjuan Huang
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748, Garching, Germany. .,Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748, Garching, Germany.
| | - Benedikt Günther
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748, Garching, Germany
| | - Klaus Achterhold
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748, Garching, Germany
| | - Yi-Tao Cui
- Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-gun, Hyogo, 679-5198, Japan
| | - Bernhard Gleich
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748, Garching, Germany
| | - Martin Dierolf
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748, Garching, Germany. .,Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748, Garching, Germany.
| | - Franz Pfeiffer
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748, Garching, Germany.,Department of Diagnostic and Interventional Radiology, Klinikum Rechts der Isar, Technical University of Munich, 81675, Munich, Germany
| |
Collapse
|
24
|
Carrillo SA. Commentary: Is X-ray Phase Contrast Imaging an Anatomical Klondike for Surgeons? Semin Thorac Cardiovasc Surg 2020; 32:969-970. [DOI: 10.1053/j.semtcvs.2020.04.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Accepted: 04/29/2020] [Indexed: 11/11/2022]
|
25
|
Synchrotron Radiation-Based Three-Dimensional Visualization of Angioarchitectural Remodeling in Hippocampus of Epileptic Rats. Neurosci Bull 2019; 36:333-345. [PMID: 31823302 DOI: 10.1007/s12264-019-00450-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 09/11/2019] [Indexed: 12/15/2022] Open
Abstract
Characterizing the three-dimensional (3D) morphological alterations of microvessels under both normal and seizure conditions is crucial for a better understanding of epilepsy. However, conventional imaging techniques cannot detect microvessels on micron/sub-micron scales without angiography. In this study, synchrotron radiation (SR)-based X-ray in-line phase-contrast imaging (ILPCI) and quantitative 3D characterization were used to acquire high-resolution, high-contrast images of rat brain tissue under both normal and seizure conditions. The number of blood microvessels was markedly increased on days 1 and 14, but decreased on day 60 after seizures. The surface area, diameter distribution, mean tortuosity, and number of bifurcations and network segments also showed similar trends. These pathological changes were confirmed by histological tests. Thus, SR-based ILPCI provides systematic and detailed views of cerebrovascular anatomy at the micron level without using contrast-enhancing agents. This holds considerable promise for better diagnosis and understanding of the pathogenesis and development of epilepsy.
Collapse
|
26
|
Muzzopappa F, Wilson A, Kirilovsky D. Interdomain interactions reveal the molecular evolution of the orange carotenoid protein. NATURE PLANTS 2019; 5:1076-1086. [PMID: 31527845 DOI: 10.1038/s41477-019-0514-9] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Accepted: 08/05/2019] [Indexed: 06/10/2023]
Abstract
The photoactive orange carotenoid protein (OCP) is a blue-light intensity sensor involved in cyanobacterial photoprotection. Three OCP families co-exist (OCPX, OCP1 and OCP2), having originated from the fusion of ancestral domain genes. Here, we report the characterization of an OCPX and the evolutionary characterization of OCP paralogues focusing on the role of the linker connecting the domains. The addition of the linker with specific amino acids enabled the photocycle of the OCP ancestor. OCPX is the paralogue closest to this ancestor. A second diversification gave rise to OCP1 and OCP2. OCPX and OCP2 present fast deactivation and weak antenna interaction. In OCP1, OCP deactivation became slower and interaction with the antenna became stronger, requiring a further protein to detach OCP from the antenna and accelerate its deactivation. OCP2 lost the tendency to dimerize, unlike OCPX and OCP1, and the role of its linker is slightly different, giving less controlled photoactivation.
Collapse
Affiliation(s)
- Fernando Muzzopappa
- Institute for Integrative Biology of the Cell, CEA, CNRS, Université Paris-Sud, Université Paris-Saclay, Gif sur Yvette, France
| | - Adjélé Wilson
- Institute for Integrative Biology of the Cell, CEA, CNRS, Université Paris-Sud, Université Paris-Saclay, Gif sur Yvette, France
| | - Diana Kirilovsky
- Institute for Integrative Biology of the Cell, CEA, CNRS, Université Paris-Sud, Université Paris-Saclay, Gif sur Yvette, France.
| |
Collapse
|
27
|
Matsumoto K, Saitoh H, Doan TLH, Shiro A, Nakai K, Komatsu A, Tsujimoto M, Yasuda R, Kawachi T, Tajima T, Tamanoi F. Destruction of tumor mass by gadolinium-loaded nanoparticles irradiated with monochromatic X-rays: Implications for the Auger therapy. Sci Rep 2019; 9:13275. [PMID: 31570738 PMCID: PMC6768997 DOI: 10.1038/s41598-019-49978-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Accepted: 08/19/2019] [Indexed: 01/21/2023] Open
Abstract
Synchrotron generated monochromatic X-rays can be precisely tuned to the K-shell energy of high Z materials resulting in the release of the Auger electrons. In this work, we have employed this mechanism to destruct tumor spheroids. We first loaded gadolinium onto the surface of mesoporous silica nanoparticles (MSNs) producing gadolinium-loaded MSN (Gd-MSN). When Gd-MSN was added to the tumor spheroids, we observed efficient uptake and uniform distribution of Gd-MSN. Gd-MSN also can be taken up into cancer cells and localize to a site just outside of the cell nucleus. Exposure of the Gd-MSN containing tumor spheroids to monochromatic X-ray beams resulted in almost complete destruction. Importantly, this effect was observed at an energy level of 50.25 keV, but not with 50.0 keV. These results suggest that it is possible to use precisely tuned monochromatic X-rays to destruct tumor mass loaded with high Z materials, while sparing other cells. Our experiments point to the importance of nanoparticles to facilitate loading of gadolinium to tumor spheroids and to localize at a site close to the nucleus. Because the nanoparticles can target to tumor, our study opens up the possibility of developing a new type of radiation therapy for cancer.
Collapse
Affiliation(s)
- Kotaro Matsumoto
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan
| | - Hiroyuki Saitoh
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science and Technology, Hyogo, Japan
| | - Tan Le Hoang Doan
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan
- Center for Innovative Materials and Architectures, Vietnam National University-Ho Chi Minh City, Ho Chi Minh City, Vietnam
| | - Ayumi Shiro
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science and Technology, Hyogo, Japan
| | - Keigo Nakai
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan
| | - Aoi Komatsu
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan
| | - Masahiko Tsujimoto
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan
| | - Ryo Yasuda
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science and Technology, Hyogo, Japan
| | - Tetsuya Kawachi
- Kansai Photon Science Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science and Technology, Hyogo, Japan
| | - Toshiki Tajima
- Department of Physics and Astronomy, University of California, Irvine, CA, USA
| | - Fuyuhiko Tamanoi
- Institute for Integrated Cell-Material Sciences, Institute for Advanced Study, Kyoto University, Kyoto, Japan.
- Department of Microbiology, Immunology and Molecular Genetics, University of California, Los Angeles, USA.
| |
Collapse
|
28
|
Günther B, Dierolf M, Achterhold K, Pfeiffer F. Device for source position stabilization and beam parameter monitoring at inverse Compton X-ray sources. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:1546-1553. [PMID: 31490142 PMCID: PMC6730616 DOI: 10.1107/s1600577519006453] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Accepted: 05/07/2019] [Indexed: 05/24/2023]
Abstract
Compact X-ray sources based on inverse Compton scattering provide brilliant and partially coherent X-rays in a laboratory environment. The cross section for inverse Compton scattering is very small, requiring high-power laser systems as well as small laser and electron beam sizes at the interaction point to generate sufficient flux. Therefore, these systems are very sensitive to distortions which change the overlap between the two beams. In order to monitor X-ray source position, size and flux in parallel to experiments, the beam-position monitor proposed here comprises a small knife edge whose image is acquired with an X-ray camera specifically designed to intercept only a very small fraction of the X-ray beam. Based on the source position drift recorded with the monitor, a closed-loop feedback stabilizes the X-ray source position by adjusting the laser beam trajectory. A decrease of long-term source position drifts by more than one order of magnitude is demonstrated with this device. Consequently, such a closed-loop feedback system which enables stabilization of source position drifts and flux of inverse Compton sources in parallel to experiments has a significant impact on the performance of these sources.
Collapse
Affiliation(s)
- Benedikt Günther
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Martin Dierolf
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Klaus Achterhold
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
| | - Franz Pfeiffer
- Department of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstraße 11, 85748 Garching, Germany
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Straße 22, 81675 München, Germany
| |
Collapse
|
29
|
Günther B, Hehn L, Jud C, Hipp A, Dierolf M, Pfeiffer F. Full-field structured-illumination super-resolution X-ray transmission microscopy. Nat Commun 2019; 10:2494. [PMID: 31175291 PMCID: PMC6555788 DOI: 10.1038/s41467-019-10537-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 05/09/2019] [Indexed: 11/20/2022] Open
Abstract
Modern transmission X-ray microscopy techniques provide very high resolution at low and medium X-ray energies, but suffer from a limited field-of-view. If sub-micrometre resolution is desired, their field-of-view is typically limited to less than one millimetre. Although the field-of-view increases through combining multiple images from adjacent regions of the specimen, so does the required data acquisition time. Here, we present a method for fast full-field super-resolution transmission microscopy by structured illumination of the specimen. This technique is well-suited even for hard X-ray energies above 30 keV, where efficient optics are hard to obtain. Accordingly, investigation of optically thick specimen becomes possible with our method combining a wide field-of-view spanning multiple millimetres, or even centimetres, with sub-micron resolution and hard X-ray energies.
Collapse
Affiliation(s)
- Benedikt Günther
- Department of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany.
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstr. 11, 85748, Garching, Germany.
- Max-Planck-Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany.
| | - Lorenz Hehn
- Department of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstr. 11, 85748, Garching, Germany
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Christoph Jud
- Department of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstr. 11, 85748, Garching, Germany
| | - Alexander Hipp
- Helmholtz-Zentrum Geesthacht, Max-Planck-Str. 1, 21502, Geesthacht, Germany
| | - Martin Dierolf
- Department of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstr. 11, 85748, Garching, Germany
| | - Franz Pfeiffer
- Department of Physics, Technical University of Munich, James-Franck-Str. 1, 85748, Garching, Germany
- Munich School of BioEngineering, Technical University of Munich, Boltzmannstr. 11, 85748, Garching, Germany
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| |
Collapse
|
30
|
Dejea H, Garcia-Canadilla P, Cook AC, Guasch E, Zamora M, Crispi F, Stampanoni M, Bijnens B, Bonnin A. Comprehensive Analysis of Animal Models of Cardiovascular Disease using Multiscale X-Ray Phase Contrast Tomography. Sci Rep 2019; 9:6996. [PMID: 31061429 PMCID: PMC6502928 DOI: 10.1038/s41598-019-43407-z] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 04/23/2019] [Indexed: 01/02/2023] Open
Abstract
Cardiovascular diseases (CVDs) affect the myocardium and vasculature, inducing remodelling of the heart from cellular to whole organ level. To assess their impact at micro and macroscopic level, multi-resolution imaging techniques that provide high quality images without sample alteration and in 3D are necessary: requirements not fulfilled by most of current methods. In this paper, we take advantage of the non-destructive time-efficient 3D multiscale capabilities of synchrotron Propagation-based X-Ray Phase Contrast Imaging (PB-X-PCI) to study a wide range of cardiac tissue characteristics in one healthy and three different diseased rat models. With a dedicated image processing pipeline, PB-X-PCI images are analysed in order to show its capability to assess different cardiac tissue components at both macroscopic and microscopic levels. The presented technique evaluates in detail the overall cardiac morphology, myocyte aggregate orientation, vasculature changes, fibrosis formation and nearly single cell arrangement. Our results agree with conventional histology and literature. This study demonstrates that synchrotron PB-X-PCI, combined with image processing tools, is a powerful technique for multi-resolution structural investigation of the heart ex-vivo. Therefore, the proposed approach can improve the understanding of the multiscale remodelling processes occurring in CVDs, and the comprehensive and fast assessment of future interventional approaches.
Collapse
Affiliation(s)
- Hector Dejea
- Paul Scherrer Institut, Villigen PSI, Switzerland.
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
| | - Patricia Garcia-Canadilla
- PhySense, DTIC, Universitat Pompeu Fabra, Barcelona, Spain
- Institute of Cardiovascular Science, University College London, London, UK
| | - Andrew C Cook
- Institute of Cardiovascular Science, University College London, London, UK
| | - Eduard Guasch
- Arrhythmia Unit, Department of Cardiology, Hospital Clínic de Barcelona, Barcelona, Spain
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
- Centro de Investigación Biomédica en Red - Cardiovascular (CIBER-CV), Madrid, Spain
| | - Monica Zamora
- BCNatal, Hospital Clínic and Hospital Sant Joan de Déu, Barcelona, Spain
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Fatima Crispi
- BCNatal, Hospital Clínic and Hospital Sant Joan de Déu, Barcelona, Spain
- Centre for Biomedical Research on Rare Diseases (CIBER-ER), Hospital Clínic, Barcelona, Spain
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Marco Stampanoni
- Paul Scherrer Institut, Villigen PSI, Switzerland
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Bart Bijnens
- PhySense, DTIC, Universitat Pompeu Fabra, Barcelona, Spain
- ICREA, Barcelona, Spain
| | - Anne Bonnin
- Paul Scherrer Institut, Villigen PSI, Switzerland
| |
Collapse
|
31
|
Wang Z, Ren K, Shi X, Ren Y, Gao K, Wu Z. Single-image phase retrieval for hard X-ray grating interferometry. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:215-219. [PMID: 30655487 DOI: 10.1107/s1600577518016727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 11/24/2018] [Indexed: 06/09/2023]
Abstract
A single-image method is proposed for quantitative phase retrieval in hard X-ray grating interferometry. This novel method assumes a quasi-homogeneous sample, with a constant ratio between the real and imaginary parts of its complex refractive index. The method is first theoretically derived and presented, and then validated by synchrotron radiation experiments. Compared with the phase-stepping method, the presented approach abandons grating scanning and multiple image acquisition, and is therefore advantageous in terms of its simplified acquisition procedure and reduced data-collection times, which are especially important for applications such as in vivo imaging and phase tomography. Moreover, the sample's phase image, instead of its first derivative, is directly retrieved. In particular, the stripe artifacts encountered in the integrated phase images are significantly suppressed. The improved quality of the retrieved phase images can be beneficial for image interpretation and subsequent processing. Owing to its requirement for a single image and its robustness against noise, the present method is expected to find use in potential investigations in diverse applications.
Collapse
Affiliation(s)
- Zhili Wang
- School of Electronic Science and Applied Physics, Hefei University of Technology, Anhui 230009, People's Republic of China
| | - Kun Ren
- School of Electronic Science and Applied Physics, Hefei University of Technology, Anhui 230009, People's Republic of China
| | - Xiaomin Shi
- School of Electronic Science and Applied Physics, Hefei University of Technology, Anhui 230009, People's Republic of China
| | - Yuqi Ren
- Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China
| | - Kun Gao
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Anhui 230026, People's Republic of China
| | - Zhao Wu
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Anhui 230026, People's Republic of China
| |
Collapse
|
32
|
Baran P, Mayo S, McCormack M, Pacile S, Tromba G, Dullin C, Zanconati F, Arfelli F, Dreossi D, Fox J, Prodanovic Z, Cholewa M, Quiney H, Dimmock M, Nesterets Y, Thompson D, Brennan P, Gureyev T. High-Resolution X-Ray Phase-Contrast 3-D Imaging of Breast Tissue Specimens as a Possible Adjunct to Histopathology. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:2642-2650. [PMID: 29994112 DOI: 10.1109/tmi.2018.2845905] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Histopathological analysis is the current gold standard in breast cancer diagnosis and management, however, as imaging technology improves, the amount of potential diagnostic information that may be demonstrable radiologically should also increase. We aimed to evaluate the potential clinical usefulness of 3-D phase-contrast micro-computed tomography (micro-CT) imaging at high spatial resolutions as an adjunct to conventional histological microscopy. Ten breast tissue specimens, 2 mm in diameter, were scanned at the SYRMEP beamline of the Elettra Synchrotron using the propagation-based phase-contrast micro-tomography method. We obtained pixel size images, which were analyzed and compared with corresponding histological sections examined under light microscopy. To evaluate the effect of spatial resolution on breast cancer diagnosis, scans with four different pixel sizes were also performed. Our comparative analysis revealed that high-resolution images can enable, at a near-histological level, detailed architectural assessment of tissue that may permit increased breast cancer diagnostic sensitivity and specificity when compared with current imaging practices. The potential clinical applications of this method are also discussed.
Collapse
|
33
|
Chi Z, Du Y, Yan L, Wang D, Zhang H, Huang W, Tang C. Experimental feasibility of dual-energy computed tomography based on the Thomson scattering X-ray source. JOURNAL OF SYNCHROTRON RADIATION 2018; 25:1797-1802. [PMID: 30407192 DOI: 10.1107/s1600577518012663] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2018] [Accepted: 09/06/2018] [Indexed: 06/08/2023]
Abstract
Unlike large-scale and expensive synchrotron radiation facilities, the Thomson scattering X-ray source can provide quasi-monochromatic, energy-tunable and high-brightness X-ray pulses with a small footprint and moderate cost, making it an excellent candidate for dual-energy and multi-energy imaging at laboratories and hospitals. Here, the first feasibility study on dual-energy computed tomography (CT) based on this type of light source is reported, and the effective atomic number and electron-density distribution of a standard phantom consisting of polytetrafluoroethylene, water and aluminium is derived. The experiment was carried out at the Tsinghua Thomson scattering X-ray source with peak energies of 29 keV and 68 keV. Both the reconstructed effective atomic numbers and the retrieved electron densities of the three materials were compared with their theoretical values. It was found that these values were in agreement by 0.68% and 2.60% on average for effective atomic number and electron density, respectively. These results have verified the feasibility of dual-energy CT based on the Thomson scattering X-ray source and will further expand the scope of X-ray imaging using this type of light source.
Collapse
Affiliation(s)
- Zhijun Chi
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
| | - Yingchao Du
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
| | - Lixin Yan
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
| | - Dong Wang
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
| | - Hongze Zhang
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
| | - Wenhui Huang
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
| | - Chuanxiang Tang
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
| |
Collapse
|
34
|
Collimated ultrabright gamma rays from electron wiggling along a petawatt laser-irradiated wire in the QED regime. Proc Natl Acad Sci U S A 2018; 115:9911-9916. [PMID: 30224456 PMCID: PMC6176611 DOI: 10.1073/pnas.1809649115] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Even though bright X-rays below mega-electron volt photon energy can be obtained from X-ray free electron lasers and synchrotron radiation facilities, it remains a great challenge to generate collimated bright gamma-ray beams over 10 mega-electron volts. We propose a scheme to efficiently generate such beams from submicron wires irradiated by petawatt lasers, where electron accelerating and wiggling are achieved simultaneously. With significant quantum electrodynamics effects existing even with petawatt lasers, our full 3D simulations show that directional gamma rays can be generated with thousand-fold higher brilliance and thousand-fold higher photon energy than those from synchrotron radiation facilities. In addition, the photon yield efficiency approaches 10%, 100,000-fold higher than those typical from betatron radiation and Compton scattering based on laser-wakefield accelerators. Even though high-quality X- and gamma rays with photon energy below mega-electron volt (MeV) are available from large-scale X-ray free electron lasers and synchrotron radiation facilities, it remains a great challenge to generate bright gamma rays over 10 MeV. Recently, gamma rays with energies up to the MeV level were observed in Compton scattering experiments based on laser wakefield accelerators, but the yield efficiency was as low as 10−6, owing to low charge of the electron beam. Here, we propose a scheme to efficiently generate gamma rays of hundreds of MeV from submicrometer wires irradiated by petawatt lasers, where electron accelerating and wiggling are achieved simultaneously. The wiggling is caused by the quasistatic electric and magnetic fields induced around the wire surface, and these are so high that even quantum electrodynamics (QED) effects become significant for gamma-ray generation, although the driving lasers are only at the petawatt level. Our full 3D simulations show that directional, ultrabright gamma rays are generated, containing 1012 photons between 5 and 500 MeV within a 10-fs duration. The brilliance, up to 1027 photons s−1 mrad−2 mm−2 per 0.1% bandwidth at an average photon energy of 20 MeV, is second only to X-ray free electron lasers, while the photon energy is 3 orders of magnitude higher than the latter. In addition, the gamma ray yield efficiency approaches 10%—that is, 5 orders of magnitude higher than the Compton scattering based on laser wakefield accelerators. Such high-energy, ultrabright, femtosecond-duration gamma rays may find applications in nuclear photonics, radiotherapy, and laboratory astrophysics.
Collapse
|
35
|
Cole JM, Symes DR, Lopes NC, Wood JC, Poder K, Alatabi S, Botchway SW, Foster PS, Gratton S, Johnson S, Kamperidis C, Kononenko O, De Lazzari M, Palmer CAJ, Rusby D, Sanderson J, Sandholzer M, Sarri G, Szoke-Kovacs Z, Teboul L, Thompson JM, Warwick JR, Westerberg H, Hill MA, Norris DP, Mangles SPD, Najmudin Z. High-resolution μCT of a mouse embryo using a compact laser-driven X-ray betatron source. Proc Natl Acad Sci U S A 2018; 115:6335-6340. [PMID: 29871946 PMCID: PMC6016801 DOI: 10.1073/pnas.1802314115] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
In the field of X-ray microcomputed tomography (μCT) there is a growing need to reduce acquisition times at high spatial resolution (approximate micrometers) to facilitate in vivo and high-throughput operations. The state of the art represented by synchrotron light sources is not practical for certain applications, and therefore the development of high-brightness laboratory-scale sources is crucial. We present here imaging of a fixed embryonic mouse sample using a compact laser-plasma-based X-ray light source and compare the results to images obtained using a commercial X-ray μCT scanner. The radiation is generated by the betatron motion of electrons inside a dilute and transient plasma, which circumvents the flux limitations imposed by the solid or liquid anodes used in conventional electron-impact X-ray tubes. This X-ray source is pulsed (duration <30 fs), bright (>1010 photons per pulse), small (diameter <1 μm), and has a critical energy >15 keV. Stable X-ray performance enabled tomographic imaging of equivalent quality to that of the μCT scanner, an important confirmation of the suitability of the laser-driven source for applications. The X-ray flux achievable with this approach scales with the laser repetition rate without compromising the source size, which will allow the recording of high-resolution μCT scans in minutes.
Collapse
Affiliation(s)
- Jason M Cole
- The John Adams Institute for Accelerator Science, Blackett Laboratory, Imperial College London, London SW7 2AZ, United Kingdom
| | - Daniel R Symes
- Central Laser Facility, Science and Technology Facilities Council (STFC) Rutherford Appleton Laboratory, Chilton, Didcot OX11 0QX, United Kingdom;
| | - Nelson C Lopes
- The John Adams Institute for Accelerator Science, Blackett Laboratory, Imperial College London, London SW7 2AZ, United Kingdom
- Group of Lasers and Plasmas (GoLP)/Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, University of Lisbon, Lisboa 1049-001, Portugal
| | - Jonathan C Wood
- The John Adams Institute for Accelerator Science, Blackett Laboratory, Imperial College London, London SW7 2AZ, United Kingdom
| | - Kristjan Poder
- The John Adams Institute for Accelerator Science, Blackett Laboratory, Imperial College London, London SW7 2AZ, United Kingdom
| | - Saleh Alatabi
- The John Adams Institute for Accelerator Science, Blackett Laboratory, Imperial College London, London SW7 2AZ, United Kingdom
| | - Stanley W Botchway
- Central Laser Facility, Science and Technology Facilities Council (STFC) Rutherford Appleton Laboratory, Chilton, Didcot OX11 0QX, United Kingdom
| | - Peta S Foster
- Central Laser Facility, Science and Technology Facilities Council (STFC) Rutherford Appleton Laboratory, Chilton, Didcot OX11 0QX, United Kingdom
| | - Sarah Gratton
- Central Laser Facility, Science and Technology Facilities Council (STFC) Rutherford Appleton Laboratory, Chilton, Didcot OX11 0QX, United Kingdom
| | - Sara Johnson
- The Mary Lyon Centre, MRC Harwell Institute, Harwell OX11 0RD, United Kingdom
| | - Christos Kamperidis
- The John Adams Institute for Accelerator Science, Blackett Laboratory, Imperial College London, London SW7 2AZ, United Kingdom
- Extreme Light Infrastructure Attosecond Light Pulse Source (ELI-ALPS), ELI-HU Non-profit Ltd., H-6720 Szeged, Hungary
| | - Olena Kononenko
- Linear Accelerator Technologies, Deutsches Elektronen-Synchrotron (DESY), 22607 Hamburg, Germany
| | - Michael De Lazzari
- Cancer Research UK/Medical Research Council (CRUK/MRC) Oxford Institute for Radiation Research, Gray Laboratories, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Charlotte A J Palmer
- Linear Accelerator Technologies, Deutsches Elektronen-Synchrotron (DESY), 22607 Hamburg, Germany
| | - Dean Rusby
- Central Laser Facility, Science and Technology Facilities Council (STFC) Rutherford Appleton Laboratory, Chilton, Didcot OX11 0QX, United Kingdom
| | - Jeremy Sanderson
- Medical Research Council (MRC) Harwell Institute, Harwell OX11 0RD, United Kingdom
| | - Michael Sandholzer
- Medical Research Council (MRC) Harwell Institute, Harwell OX11 0RD, United Kingdom
| | - Gianluca Sarri
- School of Mathematics and Physics, Queen's University, Belfast BT7 1NN, United Kingdom
| | | | - Lydia Teboul
- The Mary Lyon Centre, MRC Harwell Institute, Harwell OX11 0RD, United Kingdom
| | - James M Thompson
- Cancer Research UK/Medical Research Council (CRUK/MRC) Oxford Institute for Radiation Research, Gray Laboratories, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Jonathan R Warwick
- School of Mathematics and Physics, Queen's University, Belfast BT7 1NN, United Kingdom
| | - Henrik Westerberg
- Medical Research Council (MRC) Harwell Institute, Harwell OX11 0RD, United Kingdom
| | - Mark A Hill
- Cancer Research UK/Medical Research Council (CRUK/MRC) Oxford Institute for Radiation Research, Gray Laboratories, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Dominic P Norris
- Medical Research Council (MRC) Harwell Institute, Harwell OX11 0RD, United Kingdom
| | - Stuart P D Mangles
- The John Adams Institute for Accelerator Science, Blackett Laboratory, Imperial College London, London SW7 2AZ, United Kingdom
| | - Zulfikar Najmudin
- The John Adams Institute for Accelerator Science, Blackett Laboratory, Imperial College London, London SW7 2AZ, United Kingdom
| |
Collapse
|
36
|
Barbone GE, Bravin A, Romanelli P, Mittone A, Bucci D, Gaaβ T, Le Duc G, Auweter S, Reiser MF, Kraiger MJ, Hrabě de Angelis M, Battaglia G, Coan P. Micro-imaging of Brain Cancer Radiation Therapy Using Phase-contrast Computed Tomography. Int J Radiat Oncol Biol Phys 2018; 101:965-984. [PMID: 29976510 DOI: 10.1016/j.ijrobp.2018.03.063] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 03/23/2018] [Accepted: 03/29/2018] [Indexed: 01/20/2023]
Abstract
PURPOSE Experimental neuroimaging provides a wide range of methods for the visualization of brain anatomic morphology down to subcellular detail. Still, each technique-specific detection mechanism presents compromises among the achievable field-of-view size, spatial resolution, and nervous tissue sensitivity, leading to partial sample coverage, unresolved morphologic structures, or sparse labeling of neuronal populations and often also to obligatory sample dissection or other sample invasive manipulations. X-ray phase-contrast imaging computed tomography (PCI-CT) is an experimental imaging method that simultaneously provides micrometric spatial resolution, high soft-tissue sensitivity, and ex vivo full organ rodent brain coverage without any need for sample dissection, staining or labeling, or contrast agent injection. In the present study, we explored the benefits and limitations of PCI-CT use for in vitro imaging of normal and cancerous brain neuromorphology after in vivo treatment with synchrotron-generated x-ray microbeam radiation therapy (MRT), a spatially fractionated experimental high-dose radiosurgery. The goals were visualization of the MRT effects on nervous tissue and a qualitative comparison of the results to the histologic and high-field magnetic resonance imaging findings. METHODS AND MATERIALS MRT was administered in vivo to the brain of both healthy and cancer-bearing rats. At 45 days after treatment, the brain was dissected out and imaged ex vivo using propagation-based PCI-CT. RESULTS PCI-CT visualizes the brain anatomy and microvasculature in 3 dimensions and distinguishes cancerous tissue morphology, necrosis, and intratumor accumulation of iron and calcium deposits. Moreover, PCI-CT detects the effects of MRT throughout the treatment target areas (eg, the formation of micrometer-thick radiation-induced tissue ablation). The observed neurostructures were confirmed by histologic and immunohistochemistry examination and related to the micro-magnetic resonance imaging data. CONCLUSIONS PCI-CT enabled a unique 3D neuroimaging approach for ex vivo studies on small animal models in that it concurrently delivers high-resolution insight of local brain tissue morphology in both normal and cancerous micro-milieu, localizes radiosurgical damage, and highlights the deep microvasculature. This method could assist experimental small animal neurology studies in the postmortem evaluation of neuropathology or treatment effects.
Collapse
Affiliation(s)
- Giacomo E Barbone
- Department of Physics, Ludwig Maximilians University, Garching, Germany
| | - Alberto Bravin
- European Synchrotron Radiation Facility, Grenoble, France
| | | | | | - Domenico Bucci
- Department of Molecular Pathology, Neuropharmacology Section, I.R.C.C.S. Neuromed, Pozzilli, Italy
| | - Thomas Gaaβ
- Department of Clinical Radiology, Ludwig Maximilians University, Munich, Germany
| | | | - Sigrid Auweter
- Department of Clinical Radiology, Ludwig Maximilians University, Munich, Germany
| | - Maximilian F Reiser
- Department of Clinical Radiology, Ludwig Maximilians University, Munich, Germany
| | - Markus J Kraiger
- Institute of Experimental Genetics and German Mouse Clinic, German Research Center for Environmental Health, Neuherberg, Germany
| | - Martin Hrabě de Angelis
- Institute of Experimental Genetics and German Mouse Clinic, German Research Center for Environmental Health, Neuherberg, Germany; Department of Experimental Genetics, School of Life Science Weihenstephan, Technical University of Munich, Freising, Germany; German Center for Diabetes Research, Neuherberg, Germany
| | - Giuseppe Battaglia
- Department of Molecular Pathology, Neuropharmacology Section, I.R.C.C.S. Neuromed, Pozzilli, Italy
| | - Paola Coan
- Department of Physics, Ludwig Maximilians University, Garching, Germany; Department of Clinical Radiology, Ludwig Maximilians University, Munich, Germany.
| |
Collapse
|
37
|
Töpperwien M, Gradl R, Keppeler D, Vassholz M, Meyer A, Hessler R, Achterhold K, Gleich B, Dierolf M, Pfeiffer F, Moser T, Salditt T. Propagation-based phase-contrast x-ray tomography of cochlea using a compact synchrotron source. Sci Rep 2018; 8:4922. [PMID: 29563553 PMCID: PMC5862924 DOI: 10.1038/s41598-018-23144-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Accepted: 03/06/2018] [Indexed: 11/23/2022] Open
Abstract
We demonstrate that phase retrieval and tomographic imaging at the organ level of small animals can be advantageously carried out using the monochromatic radiation emitted by a compact x-ray light source, without further optical elements apart from source and detector. This approach allows to carry out microtomography experiments which - due to the large performance gap with respect to conventional laboratory instruments - so far were usually limited to synchrotron sources. We demonstrate the potential by mapping the functional soft tissue within the guinea pig and marmoset cochlea, including in the latter case an electrical cochlear implant. We show how 3d microanatomical studies without dissection or microscopic imaging can enhance future research on cochlear implants.
Collapse
Affiliation(s)
- Mareike Töpperwien
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany.,Center for Nanoscopy and Molecular Physiology of the Brain, Göttingen, Germany
| | - Regine Gradl
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, Germany.,Institute for Advanced Study, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Daniel Keppeler
- Institute for Auditory Neuroscience and InnerEarLab, University Medical Center Göttingen, Göttingen, Germany
| | - Malte Vassholz
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany
| | - Alexander Meyer
- InnerEarLab, Department of Otolaryngology, University Medical Center Göttingen, Göttingen, Germany
| | | | - Klaus Achterhold
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Bernhard Gleich
- Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Martin Dierolf
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, Germany.,Institute for Advanced Study, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Garching, Germany.,Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, München, Germany
| | - Tobias Moser
- Center for Nanoscopy and Molecular Physiology of the Brain, Göttingen, Germany.,Institute for Auditory Neuroscience and InnerEarLab, University Medical Center Göttingen, Göttingen, Germany.,Bernstein Focus for Neurotechnology, University of Göttingen, Göttingen, Germany
| | - Tim Salditt
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany. .,Center for Nanoscopy and Molecular Physiology of the Brain, Göttingen, Germany.
| |
Collapse
|
38
|
Sung Y, Gupta R, Nelson B, Leng S, McCollough CH, Graves WS. Phase-contrast imaging with a compact x-ray light source: system design. J Med Imaging (Bellingham) 2017; 4:043503. [PMID: 29201939 DOI: 10.1117/1.jmi.4.4.043503] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Accepted: 11/06/2017] [Indexed: 11/14/2022] Open
Abstract
X-ray phase-contrast imaging (XPCI) overcomes the problem of low contrast between different soft tissues achieved in conventional x-ray imaging by introducing x-ray phase as an additional contrast mechanism. This work describes a compact x-ray light source (CXLS) and compares, via simulations, the high quality XPCI results that can be produced from this source to those produced using a microfocus x-ray source. The simulation framework is first validated using an image acquired with a microfocus-source, propagation-based XPCI (PB-XPCI) system. The phase contrast for a water sphere simulating a simple cyst submersed in muscle is evaluated and the evolution of PB-XPCI signal as the object to detector distance is increased is demonstrated. The proposed design of a PB-XPCI system using the CXLS is described and simulated images of a coronary artery compared between CXLS and microfocus source PB-XPCI systems. To generate images with similar noise levels, a microfocus source would require a 3000 times longer exposure than would the CXLS. We conclude that CXLS technology has the potential to provide high-quality XPCI in a medical environment using extremely short exposure times relative to microfocus source approaches.
Collapse
Affiliation(s)
- Yongjin Sung
- University of Wisconsin-Milwaukee, College of Engineering and Applied Science, Milwaukee, Wisconsin, United States
| | - Rajiv Gupta
- Massachusetts General Hospital, Department of Radiology, Boston, Massachusetts, United States
| | - Brandon Nelson
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Shuai Leng
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | | | - William S Graves
- Arizona State University, Department of Physics, Tempe, Arizona, United States
| |
Collapse
|
39
|
Trabecular bone anisotropy imaging with a compact laser-undulator synchrotron x-ray source. Sci Rep 2017; 7:14477. [PMID: 29101369 PMCID: PMC5670213 DOI: 10.1038/s41598-017-14830-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 10/18/2017] [Indexed: 02/01/2023] Open
Abstract
Conventional x-ray radiography is a well-established standard in diagnostic imaging of human bones. It reveals typical bony anatomy with a strong surrounding cortical bone and trabecular structure of the inner part. However, due to limited spatial resolution, x-ray radiography cannot provide information on the microstructure of the trabecular bone. Thus, microfractures without dislocation are often missed in initial radiographs, resulting in a lack or delay of adequate therapy. Here we show that x-ray vector radiography (XVR) can overcome this limitation and allows for a deeper insight into the microstructure with a radiation exposure comparable to standard radiography. XVR senses x-ray ultrasmall-angle scattering in addition to the attenuation contrast and thereby reveals the mean scattering strength, its degree of anisotropy and the orientation of scattering structures. Corresponding to the structural characteristics of bones, there is a homogenous mean scattering signal of the trabecular bone but the degree of anisotropy is strongly affected by variations in the trabecular structure providing more detailed information on the bone microstructure. The measurements were performed at the Munich Compact Light Source, a novel type of x-ray source based on inverse Compton scattering. This laboratory-sized source produces highly brilliant quasi-monochromatic x-rays with a tunable energy.
Collapse
|
40
|
Increased cell survival and cytogenetic integrity by spatial dose redistribution at a compact synchrotron X-ray source. PLoS One 2017; 12:e0186005. [PMID: 29049300 PMCID: PMC5648152 DOI: 10.1371/journal.pone.0186005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2017] [Accepted: 09/22/2017] [Indexed: 11/24/2022] Open
Abstract
X-ray microbeam radiotherapy can potentially widen the therapeutic window due to a geometrical redistribution of the dose. However, high requirements on photon flux, beam collimation, and system stability restrict its application mainly to large-scale, cost-intensive synchrotron facilities. With a unique laser-based Compact Light Source using inverse Compton scattering, we investigated the translation of this promising radiotherapy technique to a machine of future clinical relevance. We performed in vitro colony-forming assays and chromosome aberration tests in normal tissue cells after microbeam irradiation compared to homogeneous irradiation at the same mean dose using 25 keV X-rays. The microplanar pattern was achieved with a tungsten slit array of 50 μm slit size and a spacing of 350 μm. Applying microbeams significantly increased cell survival for a mean dose above 2 Gy, which indicates fewer normal tissue complications. The observation of significantly less chromosome aberrations suggests a lower risk of second cancer development. Our findings provide valuable insight into the mechanisms of microbeam radiotherapy and prove its applicability at a compact synchrotron, which contributes to its future clinical translation.
Collapse
|
41
|
Saghamanesh S, Aghamiri SM, Kamali-Asl A, Yashiro W. Photon detection efficiency of laboratory-based x-ray phase contrast imaging techniques for mammography: a Monte Carlo study. Phys Med Biol 2017. [PMID: 28632500 DOI: 10.1088/1361-6560/aa7a92] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
An important challenge in real-world biomedical applications of x-ray phase contrast imaging (XPCI) techniques is the efficient use of the photon flux generated by an incoherent and polychromatic x-ray source. This efficiency can directly influence dose and exposure time and ideally should not affect the superior contrast and sensitivity of XPCI. In this paper, we present a quantitative evaluation of the photon detection efficiency of two laboratory-based XPCI methods, grating interferometry (GI) and coded-aperture (CA). We adopt a Monte Carlo approach to simulate existing prototypes of those systems, tailored for mammography applications. Our simulations were validated by means of a simple experiment performed on a CA XPCI system. Our results show that the fraction of detected photons in the standard energy range of mammography are about 1.4% and 10% for the GI and CA techniques, respectively. The simulations indicate that the design of the optical components plays an important role in the higher efficiency of CA compared to the GI method. It is shown that the use of lower absorbing materials as the substrates for GI gratings can improve its flux efficiency by up to four times. Along similar lines, we also show that an optimized and compact configuration of GI could lead to a 3.5 times higher fraction of detected counts compared to a standard and non-optimised GI implementation.
Collapse
Affiliation(s)
- S Saghamanesh
- Department of Medical Radiation Engineering, Shahid Beheshti University, Tehran 1983969411, Iran
| | | | | | | |
Collapse
|
42
|
|
43
|
Wang Y, Li J, Lu T, Zhang L, Zhou Z, Zhao H, Gao F. Combined diffuse optical tomography and photoacoustic tomography for enhanced functional imaging of small animals: a methodological study on phantoms. APPLIED OPTICS 2017; 56:303-311. [PMID: 28085867 DOI: 10.1364/ao.56.000303] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Hybrid imaging methods combining diffuse optical tomography (DOT) and other anatomical or nonoptical functional modalities have been widely investigated to improve imaging performance degraded by the strong optical scattering of biological tissues, through constraining the reconstruction process by prior structures. However, these modalities with different contrast mechanisms may be ineffective in revealing early-staged lesions with high optical contrast but no morphological changes. Photoacoustic tomography (PAT) is particularly useful for visualizing light-absorbing structures embedded in soft tissues with high spatial resolution. Although it is still challenging for PAT to quantitatively disclose the absorption distribution, the modality does provide reliable and specific a priori information differentiating light-absorbing structures of soft tissues and might be more appropriate to guide DOT in lesion diagnosis, as compared with other anatomical or nonoptical functional modalities. In this study, a PAT-guided DOT approach is introduced with both soft- and hard-prior regularizations. The methodology is experimentally validated on small-animal-sized phantoms using a computed-tomography-analogous (CT-analogous) PAT/DOT dual-modality system, focusing on future whole-body applications. The results show that the proposed scheme is capable of effectively improving the quantitative accuracy and spatial resolution of DOT reconstruction.
Collapse
|
44
|
Larsson DH, Vågberg W, Yaroshenko A, Yildirim AÖ, Hertz HM. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography. Sci Rep 2016; 6:39074. [PMID: 27958376 PMCID: PMC5153650 DOI: 10.1038/srep39074] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Accepted: 11/17/2016] [Indexed: 01/06/2023] Open
Abstract
X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.
Collapse
Affiliation(s)
- Daniel H. Larsson
- Department of Applied Physics, KTH Royal Institute of Technology/Albanova, 106 91 Stockholm, Sweden
| | - William Vågberg
- Department of Applied Physics, KTH Royal Institute of Technology/Albanova, 106 91 Stockholm, Sweden
| | - Andre Yaroshenko
- Physik-Department & Institut für Medizintechnik, Technische Universität München, Garching, Germany
| | - Ali Önder Yildirim
- Institute of Lung Biology and Disease, Member of the German Center for Lung Research (DZL), Helmholtz Zentrum München, Neuherberg, Germany
| | - Hans M. Hertz
- Department of Applied Physics, KTH Royal Institute of Technology/Albanova, 106 91 Stockholm, Sweden
| |
Collapse
|
45
|
Kirilovsky D, Kerfeld CA. Cyanobacterial photoprotection by the orange carotenoid protein. NATURE PLANTS 2016; 2:16180. [PMID: 27909300 DOI: 10.1038/nplants.2016.180] [Citation(s) in RCA: 129] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Accepted: 10/20/2016] [Indexed: 05/18/2023]
Abstract
In photosynthetic organisms, the production of dangerous oxygen species is stimulated under high irradiance. To cope with this stress, these organisms have evolved photoprotective mechanisms. One type of mechanism functions to decrease the energy arriving at the photochemical centres by increasing thermal dissipation at the level of antennae. In cyanobacteria, the trigger for this mechanism is the photoactivation of a soluble carotenoid protein, the orange carotenoid protein (OCP), which is a structurally and functionally modular protein. The inactive orange form (OCPo) is compact and globular, with the carotenoid spanning the effector and the regulatory domains. In the active red form (OCPr), the two domains are completely separated and the carotenoid has translocated entirely into the effector domain. The activated OCPr interacts with the phycobilisome (PBS), the cyanobacterial antenna, and induces excitation-energy quenching. A second protein, the fluorescence recovery protein (FRP), dislodges the active OCPr from the PBSs and accelerates its conversion to the inactive OCP.
Collapse
Affiliation(s)
- Diana Kirilovsky
- Institute for Integrative Biology of the Cell (I2BC), CEA, CNRS, Université Paris-Sud, Université Paris-Saclay, 91198 Gif-sur-Yvette, France
- Institut de Biologie et Technologies de Saclay (iBiTec-S), Commissariat à l'Energie Atomique (CEA), 91191 Gif-sur-Yvette, France
| | - Cheryl A Kerfeld
- MSU-DOE Plant Research Laboratory and Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, Michigan 48824, USA
- Department of Plant and Microbial Biology, University of California, Berkeley, California 94720, USA
- Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA
- Berkeley Synthetic Biology Institute, Berkeley, California 94720, USA
| |
Collapse
|
46
|
Ando M, Sunaguchi N, Shimao D, Pan A, Yuasa T, Mori K, Suzuki Y, Jin G, Kim JK, Lim JH, Seo SJ, Ichihara S, Ohura N, Gupta R. Dark-Field Imaging: Recent developments and potential clinical applications. Phys Med 2016; 32:1801-1812. [DOI: 10.1016/j.ejmp.2016.11.103] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Revised: 11/10/2016] [Accepted: 11/13/2016] [Indexed: 10/20/2022] Open
|
47
|
A Novel and Sensitive Approach for the Evaluation of Liver Ischemia-Reperfusion Injury After Liver Transplantation. Invest Radiol 2016; 51:170-6. [PMID: 26488374 DOI: 10.1097/rli.0000000000000220] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
OBJECTIVES The purpose of our study was to evaluate the potential of x-ray propagation-based phase-contrast imaging (PCI) computed tomography (CT) for the detection and characterization of early changes after ischemia-reperfusion (IR) in a standardized rat liver transplantation (LTx) model. MATERIALS AND METHODS Syngeneic orthotopic liver transplantation was performed in male Lewis rats. Ischemia-reperfusion injury (IRI)-induced changes of liver parenchyma were investigated in a time-dependent manner (2, 16, 24, and 32 hours). X-ray phase-contrast images of formalin-fixated liver specimens were acquired in CT mode by using a voxel size of 8 × 8 × 8 μm. Necrapoptotic cell death was visualized with the TdT-mediated dUTP-biotin nick end labeling technique, and alterations of liver graft microhemodynamics, that is, acinar and sinusoidal perfusion failure, were evaluated by in vivo fluorescence microscopy. RESULTS Acquired and reconstructed PCI-CT images showed an increase in necrotic liver parenchyma dependent on cold storage time, measuring 5.7% ± 1.6% after 2 hours (comparable to 2.6% ± 0.4% for sham livers), 11.5% ± 2.1% (16 hours; P < 0.05 vs control), 23.0% ± 0.5% (24 hours; P < 0.001 vs control), and 31.3% ± 2.2% (32 hours; P < 0.001 vs control). There were a significant lower number of perfused acini in dependence on increasing cold storage time. The acinar perfusion index reached 0.970 ± 0.006 after 2 hours of cold ischemia (comparable to 0.960 ± 0.009 for sham livers) and declined continuously after 16, 24, and 32 hours cold ischemia (0.58 ± 0.03, 0.49 ± 0.02, 0.41 ± 0.03, each P < 0.0001 vs controls). Comparable results were found for sinusoidal perfusion, reaching 1.8% ± 0.4% of nonperfused sinusoids for 2 hours of cold ischemia and 8.2% ± 0.8% after 16 hours, 18.8% ± 1.4% after 24 hours, and 39.0% ± 2.4% after 32 hours (each P < 0.0001 vs controls). Prolonged cold ischemia was associated with an increasing number of TdT-mediated dUTP-biotin nick end labeling-positive cells (hepatocytes and sinusoidal lining cells), reaching 0.4 ± 0.1 (sham), 0.7 ± 0.4 (2 hours), 6.4 ± 1.1 (16 hours), 2.1 ± 0.3 (24 hours), and 14.7 ± 3.5 (32 hours; P = 0.002) for hepatocytes. CONCLUSIONS X-ray PCI of histological liver specimens can detect IR-induced tissue necrosis and can provide detailed complementary 3-dimensional information to standard histopathologic findings.
Collapse
|
48
|
Eggl E, Dierolf M, Achterhold K, Jud C, Günther B, Braig E, Gleich B, Pfeiffer F. The Munich Compact Light Source: initial performance measures. JOURNAL OF SYNCHROTRON RADIATION 2016; 23:1137-42. [PMID: 27577768 DOI: 10.1107/s160057751600967x] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Accepted: 06/15/2016] [Indexed: 05/20/2023]
Abstract
While large-scale synchrotron sources provide a highly brilliant monochromatic X-ray beam, these X-ray sources are expensive in terms of installation and maintenance, and require large amounts of space due to the size of storage rings for GeV electrons. On the other hand, laboratory X-ray tube sources can easily be implemented in laboratories or hospitals with comparatively little cost, but their performance features a lower brilliance and a polychromatic spectrum creates problems with beam hardening artifacts for imaging experiments. Over the last decade, compact synchrotron sources based on inverse Compton scattering have evolved as one of the most promising types of laboratory-scale X-ray sources: they provide a performance and brilliance that lie in between those of large-scale synchrotron sources and X-ray tube sources, with significantly reduced financial and spatial requirements. These sources produce X-rays through the collision of relativistic electrons with infrared laser photons. In this study, an analysis of the performance, such as X-ray flux, source size and spectra, of the first commercially sold compact light source, the Munich Compact Light Source, is presented.
Collapse
Affiliation(s)
- Elena Eggl
- Physik-Department und Institut für Medizintechnik, Technische Universität München, James-Franck-Straße 1, 85748 Garching, Germany
| | - Martin Dierolf
- Physik-Department und Institut für Medizintechnik, Technische Universität München, James-Franck-Straße 1, 85748 Garching, Germany
| | - Klaus Achterhold
- Physik-Department und Institut für Medizintechnik, Technische Universität München, James-Franck-Straße 1, 85748 Garching, Germany
| | - Christoph Jud
- Physik-Department und Institut für Medizintechnik, Technische Universität München, James-Franck-Straße 1, 85748 Garching, Germany
| | - Benedikt Günther
- Physik-Department und Institut für Medizintechnik, Technische Universität München, James-Franck-Straße 1, 85748 Garching, Germany
| | - Eva Braig
- Physik-Department und Institut für Medizintechnik, Technische Universität München, James-Franck-Straße 1, 85748 Garching, Germany
| | - Bernhard Gleich
- Institut für Medizintechnik, Technische Universität München, Boltzmannstraße 11, 85748 Garching, Germany
| | - Franz Pfeiffer
- Physik-Department und Institut für Medizintechnik, Technische Universität München, James-Franck-Straße 1, 85748 Garching, Germany
| |
Collapse
|
49
|
Cao Y, Yin X, Zhang J, Wu T, Li D, Lu H, Hu J. Visualization of mouse spinal cord intramedullary arteries using phase- and attenuation-contrast tomographic imaging. JOURNAL OF SYNCHROTRON RADIATION 2016; 23:966-974. [PMID: 27359146 DOI: 10.1107/s1600577516006482] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Accepted: 04/17/2016] [Indexed: 06/06/2023]
Abstract
Many spinal cord circulatory disorders present the substantial involvement of small vessel lesions. The central sulcus arteries supply nutrition to a large part of the spinal cord, and, if not detected early, lesions in the spinal cord will cause irreversible damage to the function of this organ. Thus, early detection of these small vessel lesions could potentially facilitate the effective diagnosis and treatment of these diseases. However, the detection of such small vessels is beyond the capability of current imaging techniques. In this study, an imaging method is proposed and the potential of phase-contrast imaging (PCI)- and attenuation-contrast imaging (ACI)-based synchrotron radiation for high-resolution tomography of intramedullary arteries in mouse spinal cord is validated. The three-dimensional vessel morphology, particularly that of the central sulcus arteries (CSA), detected with these two imaging models was quantitatively analyzed and compared. It was determined that both PCI- and ACI-based synchrotron radiation can be used to visualize the physiological arrangement of the entire intramedullary artery network in the mouse spinal cord in both two dimensions and three dimensions at a high-resolution scale. Additionally, the two-dimensional and three-dimensional vessel morphometric parameter measurements obtained with PCI are similar to the ACI data. Furthermore, PCI allows efficient and direct discrimination of the same branch level of the CSA without contrast agent injection and is expected to provide reliable biological information regarding the intramedullary artery. Compared with ACI, PCI might be a novel imaging method that offers a powerful imaging platform for evaluating pathological changes in small vessels and may also allow better clarification of their role in neurovascular disorders.
Collapse
Affiliation(s)
- Yong Cao
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Xianzhen Yin
- Center for Drug Delivery System, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 20203, People's Republic of China
| | - Jiwen Zhang
- Center for Drug Delivery System, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 20203, People's Republic of China
| | - Tianding Wu
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Dongzhe Li
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Hongbin Lu
- Department of Sports Medicine, Research Centre of Sports Medicine, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Jianzhong Hu
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| |
Collapse
|
50
|
3D visualization of the lumbar facet joint after degeneration using propagation phase contrast micro-tomography. Sci Rep 2016; 6:21838. [PMID: 26907889 PMCID: PMC4764819 DOI: 10.1038/srep21838] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Accepted: 01/26/2016] [Indexed: 12/22/2022] Open
Abstract
Lumbar facet joint (LFJ) degeneration is believed to be an important cause of low back pain (LBP). Identifying the morphological changes of the LFJ in the degeneration process at a high-resolution level could be meaningful for our better understanding of the possible mechanisms underlying this process. In the present study, we determined the 3D morphology of the LFJ using propagation phase contrast micro-tomography (PPCT) in rats to assess the subtle changes that occur during the degeneration process. PPCT provides vivid 3D images of micromorphological changes in the LFJ during its degeneration process, and the changes in the subchondral bone occurred earlier than in the cartilage during the early stage of degeneration of the LFJ. The delineation of this alteration was similar to that with the histological method. Our findings demonstrated that PPCT could serve as a valuable tool for 3D visualization of the morphology of the LFJ by providing comprehensive information about the cartilage and the underlying subchondral bone and their changes during degeneration processes. It might also have great potential for providing effective diagnostic tools to track changes in the cartilage and to evaluate the effects of therapeutic interventions for LFJ degeneration in preclinical studies.
Collapse
|