1
|
Chen HL, Lin BS, Chang CM, Chung HW, Yang ST, Lin BS. Intelligent Neonatal Blood Perfusion Assessment System Based on Near-Infrared Spectroscopy. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE 2025; 13:23-32. [PMID: 39911773 PMCID: PMC11793855 DOI: 10.1109/jtehm.2025.3532801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2024] [Revised: 11/13/2024] [Accepted: 01/19/2025] [Indexed: 02/07/2025]
Abstract
High-risk infants in the neonatal intensive care unit often encounter the problems with hemodynamic instability, and the poor blood circulation may cause shock or other sequelae. But the appearance of shock is not easy to be noticed in the initial stage, and most of the clinical judgments are subjectively dependent on the experienced physicians. Therefore, how to effectively evaluate the neonatal blood circulation state is important for the treatment in time. Although some instruments, such as laser Doppler flow meter, can estimate the information of blood flow, there is still lack of monitoring systems to evaluate the neonatal blood circulation directly. Based on the technique of near-infrared spectroscopy, an intelligent neonatal blood perfusion assessment system was proposed in this study, to monitor the changes of hemoglobin concentration and tissue oxygen saturation simultaneously and further estimate the neonatal blood perfusion. Several indexes were defined from the changes of hemoglobin parameters under applying and relaxing pressure to obtain the neonatal perfusion information. Moreover, the neural network-based classifier was also used to effectively classify the groups with different blood perfusion states. From the experimental results, the difference between the groups with different blood perfusion states could exactly be reflected on several defined indexes and could be effectively recognized by using the technique of neural network. Clinical and Translational Impact Statement-An intelligent neonatal blood perfusion assessment system was proposed to monitor the changes of hemoglobin concentration and tissue oxygen saturation simultaneously and further estimate the neonatal blood perfusion (Category: Preclinical Research).
Collapse
Affiliation(s)
- Hsiu-Lin Chen
- Department of PediatricsKaohsiung Medical University HospitalKaohsiung807Taiwan
- Department of Respiratory TherapyCollege of MedicineKaohsiung Medical UniversityKaohsiung807Taiwan
| | - Bor-Shing Lin
- Department of Computer Science and Information EngineeringNational Taipei UniversityNew Taipei City237Taiwan
| | - Chieh-Miao Chang
- Institute of Imaging and Biomedical PhotonicsNational Yang Ming Chiao Tung UniversityTainan300Taiwan
| | - Hao-Wei Chung
- Department of PediatricsKaohsiung Medical University HospitalKaohsiung807Taiwan
- Department of Respiratory TherapyCollege of MedicineKaohsiung Medical UniversityKaohsiung807Taiwan
- College of Biological Science and TechnologyNational Yang Ming Chiao Tung UniversityHsinchu300Taiwan
| | - Shu-Ting Yang
- Department of PediatricsKaohsiung Medical University HospitalKaohsiung807Taiwan
| | - Bor-Shyh Lin
- Institute of Imaging and Biomedical PhotonicsNational Yang Ming Chiao Tung UniversityTainan300Taiwan
| |
Collapse
|
2
|
Koch Esteves N, McDonald J, González‐Alonso J. Thermo-haemodynamic coupling during regional thigh heating: Insight into the importance of local thermosensitive mechanisms in blood circulation. Exp Physiol 2024; 109:600-613. [PMID: 38230961 PMCID: PMC10988708 DOI: 10.1113/ep091556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 01/02/2024] [Indexed: 01/18/2024]
Abstract
A positive relationship between local tissue temperature and perfusion exists, with isolated limb-segment hyperthermia stimulating hyperaemia in the heated region without affecting the adjacent, non-heated limb segment. However, whether partial-limb segment heating evokes a heightened tissue perfusion in the heated region without directly or reflexly affecting the non-heated tissues of the same limb segment remains unknown. This study investigated, in 11 healthy young adults, the lower limb temperature and haemodynamic responses to three levels of 1 h upper-leg heating, none of which alter core temperature: (1) whole-thigh (WTH; water-perfused garment), (2) quadriceps (QH; water-perfused garment) and (3) partial-quadriceps (PQH; pulsed shortwave diathermy) heating. It was hypothesised that perfusion would only increase in the heated regions. WTH, QH and PQH increased local heated tissue temperature by 2.9 ± 0.6, 2.0 ± 0.7 and 2.9 ± 1.3°C (P < 0.0001), respectively, whilst remaining unchanged in the non-heated hamstrings and quadriceps tissues during QH and PQH. WTH induced a two-fold increase in common femoral artery blood flow (P < 0.0001) whereas QH and PQH evoked a similar ∼1.4-fold elevation (P ≤ 0.0018). During QH and PQH, however, tissue oxygen saturation and laser-Doppler skin blood flow in the adjacent non-heated hamstrings or quadriceps tissues remained stable (P > 0.5000). These findings in healthy young humans demonstrate a tight thermo-haemodynamic coupling during regional thigh heating, providing further evidence of the importance of local heat-activated mechanisms on the control of blood circulation.
Collapse
Affiliation(s)
- Nuno Koch Esteves
- Division of Sport, Health, and Exercise Sciences, Department of Life Sciences, College of Health, Medicine and Lifes SciencesBrunel University LondonUxbridgeUK
- University College of OsteopathyLondonUK
| | - Jeneil McDonald
- Division of Sport, Health, and Exercise Sciences, Department of Life Sciences, College of Health, Medicine and Lifes SciencesBrunel University LondonUxbridgeUK
| | - José González‐Alonso
- Division of Sport, Health, and Exercise Sciences, Department of Life Sciences, College of Health, Medicine and Lifes SciencesBrunel University LondonUxbridgeUK
| |
Collapse
|
3
|
Du Y, Wang J, Fan W, Huang R, Wang H, Liu G. Preclinical study of diabetic foot ulcers: From pathogenesis to vivo/vitro models and clinical therapeutic transformation. Int Wound J 2023; 20:4394-4409. [PMID: 37438679 PMCID: PMC10681512 DOI: 10.1111/iwj.14311] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Accepted: 06/28/2023] [Indexed: 07/14/2023] Open
Abstract
Diabetic foot ulcer (DFU), a common intractable chronic complication of diabetes mellitus (DM), has a prevalence of up to 25%, with more than 17% of the affected patients at risk of amputation or even death. Vascular risk factors, including vascular stenosis or occlusion, dyslipidemia, impaired neurosensory and motor function, and skin infection caused by trauma, all increase the risk of DFU in patients with diabetes. Therefore, diabetic foot is not a single pathogenesis. Preclinical studies have contributed greatly to the pathogenesis determination and efficacy evaluation of DFU. Many therapeutic tools are currently being investigated using DFU animal models for effective clinical translation. However, preclinical animal models that completely mimic the pathogenesis of DFU remain unexplored. Therefore, in this review, the preparation methods and evaluation criteria of DFU animal models with three major pathological mechanisms: neuropathy, angiopathy and DFU infection were discussed in detail. And the advantages and disadvantages of various DFU animal models for clinical sign simulation. Furthermore, the current status of vitro models of DFU and some preclinical studies have been transformed into clinical treatment programs, such as medical dressings, growth factor therapy, 3D bioprinting and pre-vascularization, Traditional Chinese Medicine treatment. However, because of the complexity of the pathological mechanism of DFU, the clinical transformation of DFU model still faces many challenges. We need to further optimize the existing preclinical studies of DFU to provide an effective animal platform for the future study of pathophysiology and clinical treatment of DFU.
Collapse
Affiliation(s)
- Yuqing Du
- Department of Peripheral Vascular SurgeryInstitute of surgery of traditional Chinese Medicine, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese MedicineShanghaiChina
| | - Jie Wang
- Department of Peripheral Vascular SurgeryInstitute of surgery of traditional Chinese Medicine, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese MedicineShanghaiChina
- Endocrinology departmentShanghai Municipal Hospital of Traditional Chinese Medicine, Shanghai University of Traditional Chinese MedicineShanghaiChina
| | - Weijing Fan
- Department of Peripheral Vascular SurgeryInstitute of surgery of traditional Chinese Medicine, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese MedicineShanghaiChina
| | - Renyan Huang
- Department of Peripheral Vascular SurgeryInstitute of surgery of traditional Chinese Medicine, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese MedicineShanghaiChina
| | - Hongfei Wang
- Department of Peripheral Vascular SurgeryInstitute of surgery of traditional Chinese Medicine, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese MedicineShanghaiChina
| | - Guobin Liu
- Department of Peripheral Vascular SurgeryInstitute of surgery of traditional Chinese Medicine, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese MedicineShanghaiChina
| |
Collapse
|
4
|
Hartman ME. Prefrontal NIRS signal is unaffected by forehead Doppler flux during incremental cycling exercise. Clin Physiol Funct Imaging 2023; 43:393-403. [PMID: 37243413 DOI: 10.1111/cpf.12837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 05/17/2023] [Accepted: 05/24/2023] [Indexed: 05/28/2023]
Abstract
Near-infrared spectroscopy (NIRS) is used to measure tissue concentrations of oxyhemoglobin (O2 Hb) and deoxyhemoglobin (HHb). In the context of exercise, NIRS confers a higher signal-to-noise ratio than other neuroimaging techniques. However, part of the signal may be influenced by thermoregulatory hyperemia in the superficial cutaneous capillaries of the forehead. The degree to which NIRS signals during exercise reflect cerebral or extracerebral hemodynamic changes is a continuing source of controversy. However, the influence of skin blood flow may be attenuated depending on the NIRS technique (e.g., frequency domain machines with maximal optode separation distances >3.5 cm). The purpose of this study was to compare the changes in forehead skin blood flow and cerebral hemoglobin concentration during incremental exercise versus direct vasodilation of the forehead skin induced by gradual local heating. Thirty participants (12 females, 18 males; age: 20.8 ± 3.2 years; body mass index: 23.8 ± 3.7 kg·m-2 ) participated in the study. Forehead skin blood flow was quantified laser Doppler flux and absolute concentrations of cerebral O2 Hb and HHb were measured by NIRS. Local heating significantly increased the Doppler flux signal across time and these changes were significantly correlated with skin temperature. During incremental exercise, skin temperature, Doppler flux, O2 Hb and HHb increased however, the only significant change that was consistently correlated with Doppler flux was skin temperature. Therefore, a significant change in forehead skin blood flow may not significantly the NIRS hemoglobin data, depending on the type of NIRS device used.
Collapse
Affiliation(s)
- Mark E Hartman
- Department of Kinesiology, University of Rhode Island, Kingston, Rhode Island, USA
| |
Collapse
|
5
|
Biddulph B, Morris JG, Lewis M, Hunter K, Sunderland C. Reliability of Near-Infrared Spectroscopy with and without Compression Tights during Exercise and Recovery Activities. Sports (Basel) 2023; 11:sports11020023. [PMID: 36828308 PMCID: PMC9965473 DOI: 10.3390/sports11020023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 01/06/2023] [Accepted: 01/13/2023] [Indexed: 01/20/2023] Open
Abstract
Near-infrared spectroscopy (NIRS) is widely used in sports science research, despite the limited reliability of available data. The aim of the present study was to assess the reliability of NIRS with and without compression tights. Thirteen healthy active males, (age 21.5 ± 2.7 years, body mass 82.1 ± 11.2 kg, BMI 24.6 ± 3.2 kg·m-2) completed four trials (two control trials and two trials using compression tights) over a 28-day period. During each trial, participants completed 20 min each of laying supine, sitting, walking (4 km·h-1), jogging, and sitting following the jogging. An NIRS device was attached to the muscle belly of the vastus lateralis and gastrocnemius and recorded tissue saturation index (TSI), muscle oxygenation, and muscle deoxygenation. Systematic bias and 95% limits of agreement (LOA) and coefficient of variation (CV) were used to report reliability measures for each activity type. For TSI, systematic bias (LOA) at the gastrocnemius during the control and tights trial ranged from -0.4 to 1.7% (4.4 to 10.3%) and -1.9 to 3.5% (8.1 to 12.0%), respectively. For the vastus lateralis, the systematic bias (LOA) for the control trial ranged from -2.4 to 1.0% (5.1 to 6.9%) and for the tights trial was -0.8 to 0.6% (7.0 to 9.5%). For TSI, the CV during the control trial ranged from 1.7 to 4.0% for the gastrocnemius and 1.9 to 2.6% for the vastus lateralis. During the tights trials, the CV ranged from 3.0 to 4.5% for the gastrocnemius and 2.6 to 3.5% for the vastus lateralis. The CV for muscle oxygenation during the control and tights trials for the gastrocnemius was 2.7 to 6.2% and 1.0 to 8.8% and for the vastus lateralis was 0.6 to 4.0% and 4.0 to 4.5%, respectively. The relative reliability was poorer in the tights trials, but if the aim was to detect a 5% difference in TSI, NIRS would be sufficiently reliable. However, the reliability of muscle oxygenation and deoxygenation varies considerably with activity type, and this should be considered when determining whether to employ NIRS in research studies.
Collapse
Affiliation(s)
- Brett Biddulph
- Sport, Health and Performance Enhancement (SHAPE) Research Centre, Department of Sport Science, Nottingham Trent University, Nottingham NG11 8NS, UK
| | - John G Morris
- Sport, Health and Performance Enhancement (SHAPE) Research Centre, Department of Sport Science, Nottingham Trent University, Nottingham NG11 8NS, UK
| | | | - Kirsty Hunter
- Sport, Health and Performance Enhancement (SHAPE) Research Centre, Department of Sport Science, Nottingham Trent University, Nottingham NG11 8NS, UK
| | - Caroline Sunderland
- Sport, Health and Performance Enhancement (SHAPE) Research Centre, Department of Sport Science, Nottingham Trent University, Nottingham NG11 8NS, UK
- Correspondence: ; Tel.: +44-(0)1158486379
| |
Collapse
|
6
|
Gomez A, Sainbhi AS, Froese L, Batson C, Slack T, Stein KY, Cordingley DM, Mathieu F, Zeiler FA. The Quantitative Associations Between Near Infrared Spectroscopic Cerebrovascular Metrics and Cerebral Blood Flow: A Scoping Review of the Human and Animal Literature. Front Physiol 2022; 13:934731. [PMID: 35910568 PMCID: PMC9335366 DOI: 10.3389/fphys.2022.934731] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 06/09/2022] [Indexed: 11/13/2022] Open
Abstract
Cerebral blood flow (CBF) is an important physiologic parameter that is vital for proper cerebral function and recovery. Current widely accepted methods of measuring CBF are cumbersome, invasive, or have poor spatial or temporal resolution. Near infrared spectroscopy (NIRS) based measures of cerebrovascular physiology may provide a means of non-invasively, topographically, and continuously measuring CBF. We performed a systematically conducted scoping review of the available literature examining the quantitative relationship between NIRS-based cerebrovascular metrics and CBF. We found that continuous-wave NIRS (CW-NIRS) was the most examined modality with dynamic contrast enhanced NIRS (DCE-NIRS) being the next most common. Fewer studies assessed diffuse correlation spectroscopy (DCS) and frequency resolved NIRS (FR-NIRS). We did not find studies examining the relationship between time-resolved NIRS (TR-NIRS) based metrics and CBF. Studies were most frequently conducted in humans and animal studies mostly utilized large animal models. The identified studies almost exclusively used a Pearson correlation analysis. Much of the literature supported a positive linear relationship between changes in CW-NIRS based metrics, particularly regional cerebral oxygen saturation (rSO2), and changes in CBF. Linear relationships were also identified between other NIRS based modalities and CBF, however, further validation is needed.
Collapse
Affiliation(s)
- Alwyn Gomez
- Department of Human Anatomy and Cell Science, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada
- Section of Neurosurgery, Department of Surgery, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada
| | - Amanjyot Singh Sainbhi
- Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Logan Froese
- Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Carleen Batson
- Department of Human Anatomy and Cell Science, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada
| | - Trevor Slack
- Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Kevin Y. Stein
- Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB, Canada
| | - Dean M. Cordingley
- Applied Health Sciences Program, University of Manitoba, Winnipeg, MB, Canada
- Pan Am Clinic Foundation, Winnipeg, MB, Canada
| | - Francois Mathieu
- Interdepartmental Division of Critical Care, Department of Medicine, University of Toronto, Toronto, ON, Canada
| | - Frederick A. Zeiler
- Department of Human Anatomy and Cell Science, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada
- Section of Neurosurgery, Department of Surgery, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada
- Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB, Canada
- Centre on Aging, University of Manitoba, Winnipeg, MB, Canada
- Division of Anaesthesia, Department of Medicine, Addenbrooke’s Hospital, University of Cambridge, Cambridge, MA, United Kingdom
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
7
|
Amin SB, Mugele H, Dobler FE, Marume K, Moore JP, Lawley JS. Intra-rater reliability of leg blood flow during dynamic exercise using Doppler ultrasound. Physiol Rep 2021; 9:e15051. [PMID: 34617675 PMCID: PMC8496156 DOI: 10.14814/phy2.15051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 08/30/2021] [Accepted: 08/31/2021] [Indexed: 11/24/2022] Open
Abstract
Developing an exercise model that resembles a traditional form of aerobic exercise and facilitates a complete simultaneous assessment of multiple parameters within the oxygen cascade is critically for understanding exercise intolerances in diseased populations. Measurement of muscle blood flow is a crucial component of such a model and previous studies have used invasive procedures to determine blood flow kinetics; however, this may not be appropriate in certain populations. Furthermore, current models utilizing Doppler ultrasound use isolated limb exercise and while these studies have provided useful data, the exercise model does not mimic the whole-body physiological response to continuous dynamic exercise. Therefore, we aimed to measure common femoral artery blood flow using Doppler ultrasound during continuous dynamic stepping exercise performed at three independent workloads to assess the within day and between-day reliability for such an exercise modality. We report a within-session coefficient of variation of 5.8% from three combined workloads and a between-day coefficient of variation of 12.7%. These values demonstrate acceptable measurement accuracy and support our intention of utilizing this noninvasive exercise model for an integrative assessment of the whole-body physiological response to exercise in a range of populations.
Collapse
Affiliation(s)
- Sachin B. Amin
- Department Sport ScienceDivision of Performance Physiology and PreventionUniversity InnsbruckInnsbruckAustria
| | - Hendrik Mugele
- Department Sport ScienceDivision of Performance Physiology and PreventionUniversity InnsbruckInnsbruckAustria
| | - Florian E. Dobler
- Department Sport ScienceDivision of Performance Physiology and PreventionUniversity InnsbruckInnsbruckAustria
| | | | | | - Justin S. Lawley
- Department Sport ScienceDivision of Performance Physiology and PreventionUniversity InnsbruckInnsbruckAustria
| |
Collapse
|
8
|
O'Riordan SF, McGregor R, Halson SL, Bishop DJ, Broatch JR. Sports compression garments improve resting markers of venous return and muscle blood flow in male basketball players. JOURNAL OF SPORT AND HEALTH SCIENCE 2021:S2095-2546(21)00092-2. [PMID: 34314879 PMCID: PMC10362518 DOI: 10.1016/j.jshs.2021.07.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/10/2021] [Accepted: 06/21/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND The benefits associated with sports compression garments are thought to be closely related to enhanced blood flow. However, findings are equivocal, possibly due to heterogeneity in the techniques used for measuring blood flow, the garment types used, and the pressures applied. This study combined Doppler ultrasound and near-infrared spectroscopy technologies to provide the first comprehensive assessment of the effects of 3 sports compression garment types on markers of venous return and muscle blood flow at rest. METHODS Resting lower-limb blood flow measures (markers of venous return, muscle blood flow, and muscle oxygenation) of 22 elite, junior, male basketball players (age = 17.2 ± 0.9 years, mean ± SD) were assessed in 4 separate conditions: no compression (CON), compression tights (TIGHTS), compression shorts (SHORTS), and compression socks (SOCKS). Markers of venous return (cross-sectional area, time-averaged mean and peak blood flow velocity, and venous blood flow) were measured via Doppler ultrasound at the popliteal and common femoral veins. Muscle blood flow and muscle oxygenation were measured in the gastrocnemius medialis and vastus lateralis using near-infrared spectroscopy. RESULTS Popliteal markers of venous return were higher in TIGHTS compared to CON (p < 0.01) and SHORTS (p < 0.01), with SOCKS values higher compared with CON (p < 0.05). Common femoral vein markers of venous return were higher for all conditions compared to CON (p < 0.05), with TIGHTS values also higher compared to SOCKS (p < 0.05). Gastrocnemius medialis blood flow was higher for TIGHTS compared to CON (p = 0.000), SOCKS (p = 0.012), and SHORTS (p = 0.000), with SOCKS higher compared to SHORTS (p = 0.046). Vastus lateralis blood flow was higher for TIGHTS compared to CON (p = 0.028) and SOCKS (p = 0.019), with SHORTS also higher compared to CON (p = 0.012) and SOCKS (p = 0.005). Gastrocnemius medialis oxygenation was higher for TIGHTS compared to CON (p = 0.003), SOCKS (p = 0.033), and SHORTS (p = 0.003), with SOCKS higher compared to CON (p = 0.044) and SHORTS (p = 0.032). Vastus lateralis oxygenation was higher for TIGHTS compared to CON (p = 0.020) and SOCKS (p = 0.006). CONCLUSION Markers of venous return, muscle blood flow, and muscle oxygenation are increased with sports compression garments. TIGHTS are most effective, potentially because of the larger body area compressed.
Collapse
Affiliation(s)
- Shane F O'Riordan
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia; Department of Physiology, Australian Institute of Sport, Bruce, ACT 2617, Australia.
| | - Rod McGregor
- Faculty of Health, University of Canberra, Bruce, ACT 2617, Australia
| | - Shona L Halson
- School of Behavioural and Health Sciences, Australian Catholic University, Banyo, QLD 4014, Australia
| | - David J Bishop
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia
| | - James R Broatch
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia; Department of Physiology, Australian Institute of Sport, Bruce, ACT 2617, Australia
| |
Collapse
|
9
|
Gibson OR, James CA, Mee JA, Willmott AG, Turner G, Hayes M, Maxwell NS. Heat alleviation strategies for athletic performance: A review and practitioner guidelines. Temperature (Austin) 2019; 7:3-36. [PMID: 32166103 PMCID: PMC7053966 DOI: 10.1080/23328940.2019.1666624] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Revised: 09/06/2019] [Accepted: 09/08/2019] [Indexed: 12/19/2022] Open
Abstract
International competition inevitably presents logistical challenges for athletes. Events such as the Tokyo 2020 Olympic Games require further consideration given historical climate data suggest athletes will experience significant heat stress. Given the expected climate, athletes face major challenges to health and performance. With this in mind, heat alleviation strategies should be a fundamental consideration. This review provides a focused perspective of the relevant literature describing how practitioners can structure male and female athlete preparations for performance in hot, humid conditions. Whilst scientific literature commonly describes experimental work, with a primary focus on maximizing magnitudes of adaptive responses, this may sacrifice ecological validity, particularly for athletes whom must balance logistical considerations aligned with integrating environmental preparation around training, tapering and travel plans. Additionally, opportunities for sophisticated interventions may not be possible in the constrained environment of the athlete village or event arenas. This review therefore takes knowledge gained from robust experimental work, interprets it and provides direction on how practitioners/coaches can optimize their athletes' heat alleviation strategies. This review identifies two distinct heat alleviation themes that should be considered to form an individualized strategy for the athlete to enhance thermoregulatory/performance physiology. First, chronic heat alleviation techniques are outlined, these describe interventions such as heat acclimation, which are implemented pre, during and post-training to prepare for the increased heat stress. Second, acute heat alleviation techniques that are implemented immediately prior to, and sometimes during the event are discussed. Abbreviations: CWI: Cold water immersion; HA: Heat acclimation; HR: Heart rate; HSP: Heat shock protein; HWI: Hot water immersion; LTHA: Long-term heat acclimation; MTHA: Medium-term heat acclimation; ODHA: Once-daily heat acclimation; RH: Relative humidity; RPE: Rating of perceived exertion; STHA: Short-term heat acclimation; TCORE: Core temperature; TDHA: Twice-daily heat acclimation; TS: Thermal sensation; TSKIN: Skin temperature; V̇O2max: Maximal oxygen uptake; WGBT: Wet bulb globe temperature.
Collapse
Affiliation(s)
- Oliver R. Gibson
- Centre for Human Performance, Exercise and Rehabilitation (CHPER), Division of Sport, Health and Exercise Sciences, Brunel University London, Uxbridge, UK
| | - Carl A. James
- Institut Sukan Negara (National Sports Institute), Kuala Lumpur, Malaysia
| | - Jessica A. Mee
- School of Sport and Exercise Sciences, University of Worcester, Worcester, UK
| | - Ashley G.B. Willmott
- Cambridge Centre for Sport and Exercise Sciences, Anglia Ruskin University, Cambridge, UK
| | - Gareth Turner
- Bisham Abbey National High-Performance Centre, English Institute of Sport, EIS Performance Centre, Marlow, UK
| | - Mark Hayes
- Environmental Extremes Laboratory, School of Sport and Service Management, University of Brighton, Eastbourne, UK
| | - Neil S. Maxwell
- Environmental Extremes Laboratory, School of Sport and Service Management, University of Brighton, Eastbourne, UK
| |
Collapse
|
10
|
Quaresima V, Farzam P, Anderson P, Farzam PY, Wiese D, Carp SA, Ferrari M, Franceschini MA. Diffuse correlation spectroscopy and frequency-domain near-infrared spectroscopy for measuring microvascular blood flow in dynamically exercising human muscles. J Appl Physiol (1985) 2019; 127:1328-1337. [PMID: 31513443 DOI: 10.1152/japplphysiol.00324.2019] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
In the last 20 yr, near-infrared diffuse correlation spectroscopy (DCS) has been developed for providing a noninvasive estimate of microvascular blood flow (BF) as a BF index (BFi) in the human skin, muscle, breast, brain, and other tissue types. In this study, we proposed a new motion correction algorithm for DCS-derived BFi able to remove motion artifacts during cycling exercise. We tested this algorithm on DCS data collected during cycling exercise and demonstrated that DCS can be used to quantify muscle BFi during dynamic high-intensity exercise. In addition, we measured tissue regional oxygen metabolic rate (MRO2i) by combining frequency-domain multidistance near-infrared spectroscopy (FDNIRS) oximetry with DCS flow measures. Recreationally active subjects (n = 12; 31 ± 8 yr, 183 ± 4 cm, 79 ± 10 kg) pedaled at 80-100 revolutions/min until volitional fatigue with a work rate increase of 30 W every 4 min. Exercise intensity was normalized in each subject to the cycling power peak (Wpeak). Both rectus femoris BFi and MRO2i increased from 15% up to 75% Wpeak and then plateaued to the end of the exercise. During the recovery at 30 W cycling power, BFi remained almost constant, whereas MRO2i started to decrease. The BFi/MRO2i plateau was associated with the rising of the lactate concentration, indicating the progressive involvement of the anaerobic metabolism. These findings further highlight the utility of DCS and FDNIRS oximetry as effective, reproducible, and noninvasive techniques to assess muscle BFi and MRO2i in real time during a dynamic exercise such as cycling.NEW & NOTEWORTHY To the best of our knowledge, this study is the first to demonstrate that diffuse correlation spectroscopy in combination with frequency-domain near-infrared spectroscopy can monitor human quadriceps microvascular blood flow and oxygen metabolism with high temporal resolution during a cycling exercise. The optically measured parameters confirm the expected relationship between blood flow, muscle oxidative metabolism, and lactate production during exercise.
Collapse
Affiliation(s)
- Valentina Quaresima
- Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| | - Parisa Farzam
- Optics at Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts
| | | | - Parya Y Farzam
- Optics at Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts
| | | | - Stefan A Carp
- Optics at Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts
| | - Marco Ferrari
- Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| | - Maria Angela Franceschini
- Optics at Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts
| |
Collapse
|
11
|
Choo HC, Peiffer JJ, Lopes-Silva JP, Mesquita RNO, Amano T, Kondo N, Abbiss CR. Effect of ice slushy ingestion and cold water immersion on thermoregulatory behavior. PLoS One 2019; 14:e0212966. [PMID: 30811512 PMCID: PMC6392407 DOI: 10.1371/journal.pone.0212966] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2018] [Accepted: 02/12/2019] [Indexed: 11/18/2022] Open
Abstract
Two studies were conducted to examine the effects of ice slushy ingestion (ICE) and cold water immersion (CWI) on thermoregulatory and sweat responses during constant (study 1) and self-paced (study 2) exercise. In study 1, 11 men cycled at 40-50% of peak aerobic power for 60 min (33.2 ± 0.3°C, 45.9 ± 0.5% relative humidity, RH). In study 2, 11 men cycled for 60 min at perceived exertion (RPE) equivalent to 15 (33.9 ± 0.2°C and 42.5 ± 3.9%RH). In both studies, each trial was preceded by 30 min of CWI (~22°C), ICE or no cooling (CON). Rectal temperature (Tre), skin temperature (Tsk), thermal sensation, and sweat responses were measured. In study 1, ICE decreased Tre-Tsk gradient versus CON (p = 0.005) during first 5 min of exercise, while CWI increased Tre-Tsk gradient versus CON and ICE for up to 20 min during the exercise (p<0.05). In study 2, thermal sensation was lower in CWI versus CON and ICE for up to 35-40 min during the exercise (p<0.05). ICE reduced thermal sensation versus CON during the first 20 min of exercise (p<0.05). In study 2, CWI improved mean power output (MPO) by ~8 W, compared with CON only (p = 0.024). In both studies, CWI (p<0.001) and ICE (p = 0.019) delayed sweating by 1-5 min but did not change the body temperature sweating threshold, compared with CON (both p>0.05). Increased Tre-Tsk gradient by CWI improved MPO while ICE reduced Tre but did not confer any ergogenic effect. Both precooling treatments attenuated the thermal efferent signals until a specific body temperature threshold was reached.
Collapse
Affiliation(s)
- Hui C. Choo
- Centre for Exercise and Sports Science Research, School of Medical and
Health Sciences, Edith Cowan University, Joondalup, Western Australia,
Australia
- * E-mail:
| | - Jeremiah J. Peiffer
- School of Psychology and Exercise Science, Murdoch University, Murdoch,
Western, Australia, Australia
| | - João P. Lopes-Silva
- School of Physical Education and Sport, University of São Paulo (USP),
São Paulo, São Paulo, Brazil
| | - Ricardo N. O. Mesquita
- Centre for Exercise and Sports Science Research, School of Medical and
Health Sciences, Edith Cowan University, Joondalup, Western Australia,
Australia
| | - Tatsuro Amano
- Faculty of Education, Niigata University, Niigata, Niigata Prefecture,
Japan
| | - Narihiko Kondo
- Laboratory for Applied Human Physiology, Graduate School of Human
Development and Environment, Kobe University, Kobe, Hyōgo Prefecture,
Japan
| | - Chris R. Abbiss
- Centre for Exercise and Sports Science Research, School of Medical and
Health Sciences, Edith Cowan University, Joondalup, Western Australia,
Australia
| |
Collapse
|
12
|
A Numerical Model of Blood Flow Velocity Measurement Based on Finger Ring. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:3916481. [PMID: 30402212 PMCID: PMC6192088 DOI: 10.1155/2018/3916481] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2017] [Accepted: 07/31/2018] [Indexed: 11/17/2022]
Abstract
Aiming to measure the blood flow velocity in a finger, a novel noninvasive method, i.e., a ring with a heat source chip and a temperature sensor, is designed in this paper. The heat source chip is used to heat the finger and generate heat diffusion between the chip and the temperature sensor. And the temperature sensor is designed to measure the temperature difference. Since the blood flow is the main medium of heat diffusion in bodies, part from the heat energy in the tissue will be taken away by the flowing blood. Therefore, the blood flow velocity can be acquired via its relationship with the temperature difference. Compared to the ultrasound Doppler method and the laser Doppler method, the proposed method guarantees a more convenient operation in more flexible work sites. We also analyze the theory between heat transfer and laminar flow. Finally, several simulations are conducted, and the influence of the relevant factors (i.e., the number of blood vessels, the radius, etc.) corresponding to the simulation results is also discussed.
Collapse
|
13
|
De Smet S, van Herpt P, D'Hulst G, Van Thienen R, Van Leemputte M, Hespel P. Physiological Adaptations to Hypoxic vs. Normoxic Training during Intermittent Living High. Front Physiol 2017; 8:347. [PMID: 28620311 PMCID: PMC5449743 DOI: 10.3389/fphys.2017.00347] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Accepted: 05/11/2017] [Indexed: 12/16/2022] Open
Abstract
In the setting of “living high,” it is unclear whether high-intensity interval training (HIIT) should be performed “low” or “high” to stimulate muscular and performance adaptations. Therefore, 10 physically active males participated in a 5-week “live high-train low or high” program (TR), whilst eight subjects were not engaged in any altitude or training intervention (CON). Five days per week (~15.5 h per day), TR was exposed to normobaric hypoxia simulating progressively increasing altitude of ~2,000–3,250 m. Three times per week, TR performed HIIT, administered as unilateral knee-extension training, with one leg in normobaric hypoxia (~4,300 m; TRHYP) and with the other leg in normoxia (TRNOR). “Living high” elicited a consistent elevation in serum erythropoietin concentrations which adequately predicted the increase in hemoglobin mass (r = 0.78, P < 0.05; TR: +2.6%, P < 0.05; CON: −0.7%, P > 0.05). Muscle oxygenation during training was lower in TRHYP vs. TRNOR (P < 0.05). Muscle homogenate buffering capacity and pH-regulating protein abundance were similar between pretest and posttest. Oscillations in muscle blood volume during repeated sprints, as estimated by oscillations in NIRS-derived tHb, increased from pretest to posttest in TRHYP (~80%, P < 0.01) but not in TRNOR (~50%, P = 0.08). Muscle capillarity (~15%) as well as repeated-sprint ability (~8%) and 3-min maximal performance (~10–15%) increased similarly in both legs (P < 0.05). Maximal isometric strength increased in TRHYP (~8%, P < 0.05) but not in TRNOR (~4%, P > 0.05). In conclusion, muscular and performance adaptations were largely similar following normoxic vs. hypoxic HIIT. However, hypoxic HIIT stimulated adaptations in isometric strength and muscle perfusion during intermittent sprinting.
Collapse
Affiliation(s)
- Stefan De Smet
- Department of Kinesiology, Exercise Physiology Research Group, KU LeuvenLeuven, Belgium
| | - Paul van Herpt
- Department of Kinesiology, Exercise Physiology Research Group, KU LeuvenLeuven, Belgium
| | - Gommaar D'Hulst
- Department of Kinesiology, Exercise Physiology Research Group, KU LeuvenLeuven, Belgium
| | - Ruud Van Thienen
- Department of Kinesiology, Exercise Physiology Research Group, KU LeuvenLeuven, Belgium
| | - Marc Van Leemputte
- Department of Kinesiology, Exercise Physiology Research Group, KU LeuvenLeuven, Belgium
| | - Peter Hespel
- Department of Kinesiology, Exercise Physiology Research Group, KU LeuvenLeuven, Belgium.,Athletic Performance Center, Bakala Academy, KU LeuvenLeuven, Belgium
| |
Collapse
|