1
|
Janowski C, Nguyen T, da Silveira CB, Gulati S, Deka V, Thomas Gillespie, Ballecer C. A randomized controlled trial of the outcomes of Arista™ hemostatic agent in robotic ventral hernia repair. J Robot Surg 2025; 19:81. [PMID: 39998726 DOI: 10.1007/s11701-025-02252-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2024] [Accepted: 02/18/2025] [Indexed: 02/27/2025]
Abstract
Ventral hernia repairs (VHR) are commonly performed surgical procedures in the United States, with over 300,000 cases treated annually. Robotic surgery has gained traction for its safety and efficacy in VHR, particularly with techniques such as myofascial release. However, the extensive dissection involved in these procedures may lead to postoperative complications like seromas and hematomas. This study aims to assess the effectiveness of Arista™, an FDA-approved hemostatic agent, in reducing these complications during robotic-assisted laparoscopic VHR involving mesh placement in the retrorectus space. This single-institution single-blind prospective randomized controlled trial involved 100 patients undergoing elective robotic-assisted laparoscopic VHR at a tertiary referral hernia center. Participants were randomized to receive either 5 g of Arista™ or standard of care intraoperatively, with no hemostat applied in the control group. All patients had drains placed in the retrorectus space. Primary outcomes included drain output on the first postoperative day (POD), total drain output, and duration of drain placement. Secondary outcomes included estimated blood loss (EBL), number of drains used, operative time, and length of stay (LOS). This study was funded by Becton, Dickinson and Company (BD). The mean total drain output was significantly higher in the Arista™ group (592.8 ml) compared to the control group (407.9 ml; p = 0.01), with a 39.6% increase noted. However, no significant difference in drain output on the first postoperative day or drain duration was observed. Secondary outcomes revealed no statistically significant differences in EBL, number of drains, operative time, or LOS between the groups. While the application of Arista™ during robotic-assisted laparoscopic VHR resulted in increased total drain output, it did not significantly affect other postoperative metrics, including LOS and complications. Further research is warranted to explore the potential benefits of Arista™ in specific patient populations and surgical contexts.
Collapse
Affiliation(s)
- Courtney Janowski
- Creighton University School of Medicine General Surgery Residency, Phoenix, AZ, USA
| | - Tiffany Nguyen
- Creighton University School of Medicine General Surgery Residency, Phoenix, AZ, USA
| | | | - Snigdha Gulati
- Dignity Health St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
| | - Vikram Deka
- Creighton University School of Medicine General Surgery Residency, Phoenix, AZ, USA
- Dignity Health St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
| | - Thomas Gillespie
- Creighton University School of Medicine General Surgery Residency, Phoenix, AZ, USA
- Dignity Health St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
| | - Conrad Ballecer
- Creighton University School of Medicine General Surgery Residency, Phoenix, AZ, USA
- Dignity Health St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
| |
Collapse
|
2
|
Matsui Y, Higuchi S, Mori F, Takehisa K, Kikuchi K, Kikuchi H, Hirobe K, Maeda R, Tsukamoto K, Saito T, Shoda M, Yamaguchi J. Microporous polysaccharide hemospheres for reducing pocket hematomas after cardiac device implantation in patients on antithrombotic therapy. J Arrhythm 2024; 40:1150-1157. [PMID: 39416235 PMCID: PMC11474689 DOI: 10.1002/joa3.13130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 06/30/2024] [Accepted: 08/01/2024] [Indexed: 10/19/2024] Open
Abstract
Background Various surgical procedures have employed microporous polysaccharide hemosphere (MPH) hemostatic agents. However, data regarding their effectiveness in preventing pocket hematomas (PHs) during the implantation of cardiac implantable electronic devices (CIED) among the Asian population are limited. Therefore, this study aimed to investigate the potential benefits of using MPH hemostatic agents during CIED implantations as a preventive measure against post-procedural PHs. Methods We conducted a retrospective, single-center, observational study involving 255 consecutive Japanese patients who underwent CIED implantation between November 2017 and April 2021. We compared PH occurrences within 28 days after CIED implantation between patients who received MPH hemostatic agents (n = 145) and those who did not (n = 110). Results PH development was observed in nine (6.2%) patients who received MPH hemostatic agents and in 13 (11.8%) patients without MPH hemostatic (p = .111). Kaplan-Meier analysis of PH development revealed no significant difference between the two groups (log-rank p = .102). However, utilizing MPH hemostatic agents among patients taking antithrombotic drugs, including antiplatelet medications, direct oral anticoagulants, and warfarin, significantly reduced PH incidence (log-rank p = .03). The multivariate Cox proportional hazards model demonstrated that MPH hemostatic agent utilization independently correlated with a decreased PH risk (hazard ratio 0.22, 95% confidence interval 0.08-0.63, p = .004). Conclusions The findings of this study suggest that the incorporation of MPH hemostatic agents into standard practice may benefit to mitigate PH risk during CIED implantations in patients on antithrombotic therapy. This simple and practical measure may be valuable, especially in high-risk patients, such as those taking antithrombotic medications.
Collapse
Affiliation(s)
- Yuko Matsui
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Satoshi Higuchi
- Department of CardiologyTokyo Women's Medical UniversityTokyoJapan
| | - Fumiaki Mori
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Kao Takehisa
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Kensuke Kikuchi
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Haruka Kikuchi
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Kohei Hirobe
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Ryozo Maeda
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Kei Tsukamoto
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Takashi Saito
- Department of CardiologyNational Hospital Organization Yokohama Medical CenterYokohama‐shiKanagawaJapan
| | - Morio Shoda
- Department of CardiologyTokyo Women's Medical UniversityTokyoJapan
| | | |
Collapse
|
3
|
de Jong DLC, Wegdam JA, Van der Wolk S, Nienhuijs SW, de Vries Reilingh TS. Prevention of component separation in complex abdominal wall surgery by Botox prehabilitation: a propensity-matched study. Hernia 2024; 28:815-821. [PMID: 38172376 DOI: 10.1007/s10029-023-02929-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 11/05/2023] [Indexed: 01/05/2024]
Abstract
AIM To facilitate midline fascial closure in complex abdominal wall surgery, component separation techniques (CST) are usually required. However, CST is associated with an enlarged morbidity. Prehabilitation could increase the compliance of the abdominal wall and thereby decrease the necessity of myofascial release. This can be accomplished by administration of botulinum toxin type A (BTA) in the lateral abdominal wall musculature. The aim of this study was to determine the effect of BTA on the subsequent necessity to perform CST in patients with complex abdominal wall hernias. METHODS Patients with a complex abdominal wall hernia, planned to undergo CST between July 2020 and November 2022 were included. Outcome of procedures with 300U of BTA 4 (2-6) weeks prior to surgery, were retrospectively analyzed by comparison with propensity matched subjects of an historical group. Hernia width difference was assessed by CT and operative details were included. RESULTS A total of 13 patients with a median hernia width of 12 cm (IQR 9-14, range 24) were prehabilitated with BTA between July 2020 and November 2022. A CST was planned for all, however not required in 6/13 patients (46%) to accomplish midline fascial closure. A mean elongation of lateral abdominal wall musculature of 4.01 cm was seen in patients not requiring CST. Compared to the propensity score matched control group, a 27% reduction (p = 0.08) in the need for CST was observed. CONCLUSION There is a tendency for decrease of necessity for CST by preoperatively administered BTA in patients with complex abdominal wall defects. Although small, as this study used propensity matched comparison, further exploration of BTA should be encouraged.
Collapse
Affiliation(s)
| | - J A Wegdam
- Elkerliek Ziekenhuis, Helmond, The Netherlands
| | | | | | | |
Collapse
|
4
|
LyBarger KS. Review of Evidence Supporting the Arista™ Absorbable Powder Hemostat. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2024; 17:173-188. [PMID: 38800552 PMCID: PMC11127658 DOI: 10.2147/mder.s442944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 03/21/2024] [Indexed: 05/29/2024] Open
Abstract
Background Uncontrolled and diffuse bleeding is a dreaded event during open and laparoscopic surgery that may lead to postoperative complications, obstruction of the surgical field that reduces visualization, and prolonged operating times. Powder hemostats can be used to control bleeding and are easy to use, have a safe profile, and can achieve broad coverage area at a low cost. Methods A strategic literature search of peer-reviewed, English language studies was conducted to capture evidence on the clinical efficacy and safety of a Microporous Polysaccharide Hemosphere (MPH) based Hemostat (Arista™ Absorbable Hemostat (Arista™ AH)). Results Six preclinical studies were found which supported the use of MPH in various animal models of laparoscopic and open surgery, all of which demonstrated its safety and efficacy. Five single-arm and 11 comparative clinical studies similarly supported the efficacy and safety of MPH in various surgery types, including cardiac, renal, and dermatologic surgery. Conclusion Published evidence supports the safe and effective use of MPH across a variety of surgical settings.
Collapse
|
6
|
Burri H, Starck C, Auricchio A, Biffi M, Burri M, D'Avila A, Deharo JC, Glikson M, Israel C, Lau CP, Leclercq C, Love CJ, Nielsen JC, Vernooy K, Dagres N, Boveda S, Butter C, Marijon E, Braunschweig F, Mairesse GH, Gleva M, Defaye P, Zanon F, Lopez-Cabanillas N, Guerra JM, Vassilikos VP, Martins Oliveira M. EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS). Europace 2021; 23:983-1008. [PMID: 33878762 DOI: 10.1093/europace/euaa367] [Citation(s) in RCA: 114] [Impact Index Per Article: 28.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
With the global increase in device implantations, there is a growing need to train physicians to implant pacemakers and implantable cardioverter-defibrillators. Although there are international recommendations for device indications and programming, there is no consensus to date regarding implantation technique. This document is founded on a systematic literature search and review, and on consensus from an international task force. It aims to fill the gap by setting standards for device implantation.
Collapse
Affiliation(s)
- Haran Burri
- Department of Cardiology, University Hospital of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva, Switzerland
| | - Christoph Starck
- Department of Cardiothoracic and Vascular Surgery, German Heart Center, Berlin, Augustenburger Pl. 1, 13353 Berlin, Germany.,German Center of Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany.,Steinbeis University Berlin, Institute (STI) of Cardiovascular Perfusion, Berlin, Germany
| | - Angelo Auricchio
- Fondazione Cardiocentro Ticino, Via Tesserete 48, CH-6900 Lugano, Switzerland
| | - Mauro Biffi
- Azienda Ospedaliero-Universitaria di Bologna, Policlinico S.Orsola-Malpighi, Università di Bologna, Bologna, Italy
| | - Mafalda Burri
- Division of Scientific Information, University of Geneva, Rue Michel Servet 1, 1211 Geneva, Switzerland
| | - Andre D'Avila
- Serviço de Arritmia Cardíaca-Hospital SOS Cardio, 2 Florianópolis, SC, Brazil.,Harvard-Thorndike Electrophysiology Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | | | | | - Carsten Israel
- Department of Cardiology, Bethel-Clinic Bielefeld, Burgsteig 13, 33617, Bielefeld, Germany
| | - Chu-Pak Lau
- Division of Cardiology, University of Hong Kong, Queen Mary Hospital, Pok Fu Lam, Hong Kong
| | | | - Charles J Love
- Johns Hopkins Hospital and School of Medicine, Baltimore, MD, USA
| | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 161, 8200 Aarhus, Denmark
| | - Kevin Vernooy
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands.,Department of Cardiology, Radboud University Medical Center (Radboudumc), Nijmegen, The Netherlands
| | | | - Nikolaos Dagres
- Department of Electrophysiology, Heart Center Leipzig at University of Leipzig, Leipzig, Germany
| | - Serge Boveda
- Heart Rhythm Department, Clinique Pasteur, 31076 Toulouse, France
| | - Christian Butter
- Department of Cardiology, Heart Center Brandenburg, Chefarzt, Abteilung Kardiologie, Berlin, Germany
| | - Eloi Marijon
- University of Paris, Head of Cardiac Electrophysiology Section, European Georges Pompidou Hospital, 20 Rue Leblanc, 75908 Paris Cedex 15, France
| | | | - Georges H Mairesse
- Department of Cardiology-Electrophysiology, Cliniques du Sud Luxembourg-Vivalia, rue des Deportes 137, BE-6700 Arlon, Belgium
| | - Marye Gleva
- Washington University in St Louis, St Louis, MO, USA
| | - Pascal Defaye
- CHU Grenoble Alpes, Unite de Rythmologie, Service De Cardiologie, CS10135, 38043 Grenoble Cedex 09, France
| | - Francesco Zanon
- Arrhythmia and Electrophysiology Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy
| | | | - Jose M Guerra
- Department of Cardiology, Hospital de la Santa Creu i Sant Pau, Universidad Autonoma de Barcelona, CIBERCV, Barcelona, Spain
| | - Vassilios P Vassilikos
- Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece.,3rd Cardiology Department, Hippokrateio General Hospital, Thessaloniki, Greece
| | - Mario Martins Oliveira
- Department of Cardiology, Hospital Santa Marta, Rua Santa Marta, 1167-024 Lisbon, Portugal
| |
Collapse
|
7
|
Barbar T, Patel R, Thomas G, Cheung JW. Strategies to Prevent Cardiac Implantable Electronic Device Infection. J Innov Card Rhythm Manag 2020; 11:3949-3956. [PMID: 32368364 PMCID: PMC7192142 DOI: 10.19102/icrm.2020.110102] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Accepted: 10/16/2019] [Indexed: 12/15/2022] Open
Abstract
The association between the risk of mortality and cardiovascular implantable electronic device (CIED) infections has been well-established in the literature. As CIED implantations have increased in frequency in the past few decades, the incidence of CIED-related infections has also risen. Given the morbidity, mortality, and health-care costs associated with CIED infections, the prevention of device-related infection is a critical goal. Risk factors for developing CIED infections can be categorized as patient-, procedure-, or device-related. Numerous studies have highlighted different strategies for preventing CIED-related infections, which include patient optimization, device selection, and periprocedural preparation and treatment. Nonetheless, as the comorbidity burden of patients undergoing CIED implantation continues to increase, significant challenges in the successful elimination of CIED-related infections remain. This review provides a comprehensive overview of available evidence-based approaches and strategies to reduce the risk of CIED infections.
Collapse
Affiliation(s)
- Tarek Barbar
- Division of Cardiology, Department of Medicine, Weill Cornell Medicine-New York Presbyterian Hospital, New York, NY, USA
| | - Rohan Patel
- Division of Cardiology, Department of Medicine, Weill Cornell Medicine-New York Presbyterian Hospital, New York, NY, USA
| | - George Thomas
- Division of Cardiology, Department of Medicine, Weill Cornell Medicine-New York Presbyterian Hospital, New York, NY, USA
| | - Jim W Cheung
- Division of Cardiology, Department of Medicine, Weill Cornell Medicine-New York Presbyterian Hospital, New York, NY, USA
| |
Collapse
|