1
|
Yasuda M, Uchida R, Kamai Y, Morita H, Tanaka M, Ishida T, Mochizuki M, Yamamoto M, Hayashimoto N, Kawai K. Interstitial pneumonia in immunocompetent laboratory rats caused by natural infection with Pneumocystis carinii. Exp Anim 2021; 71:53-59. [PMID: 34511543 PMCID: PMC8828405 DOI: 10.1538/expanim.21-0091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Pneumocystis (P.) carinii is known to cause fatal pneumonia in immunocompromised rats. Cases of P. carinii interstitial
pneumonia in immunocompetent rats have been shown histologically to present with perivascular lymphoid cuffs, which have previously been attributed to rat respiratory virus. This study aims
to determine the prevalence and pathological characteristics of P. carinii in immunocompetent laboratory rats in experimental facilities in Japan. An epidemiological survey
for this agent was performed using PCR to assess 1,981 immunocompetent rats from 594 facilities in Japan. We observed that 6 of the 1,981 rats (0.30%) from 4 out of 594 facilities (0.67%)
were positive for P. carinii without infection of other known pathogens. Gross pulmonary lesions were found in 4 of the 6 affected rats. The lungs of these rats contained
scattered dark red/gray foci. Histopathologically, the lungs exhibited interstitial pneumonia with lymphoid perivascular cuffs: Pneumocystis cysts were observed using
Grocott’s methenamine silver stain. To our knowledge, this report is the first to reveal the prevalence of natural P. carinii infection in immunocompetent laboratory rats in
Japan.
Collapse
Affiliation(s)
- Masahiko Yasuda
- Pathology Analysis Center, Central Institute for Experimental Animals
| | - Ritsuki Uchida
- ICLAS Monitoring Center, Central Institute for Experimental Animals.,JAC Inc
| | - Yoko Kamai
- Pathology Analysis Center, Central Institute for Experimental Animals
| | - Hanako Morita
- ICLAS Monitoring Center, Central Institute for Experimental Animals
| | - Mai Tanaka
- ICLAS Monitoring Center, Central Institute for Experimental Animals
| | - Tomoko Ishida
- ICLAS Monitoring Center, Central Institute for Experimental Animals
| | - Misa Mochizuki
- Pathology Analysis Center, Central Institute for Experimental Animals
| | | | | | - Kenji Kawai
- Pathology Analysis Center, Central Institute for Experimental Animals
| |
Collapse
|
2
|
Cantara SI, Kick BL, Roach CE, Meeks ME, Nagy T. Pathology in Practice. J Am Vet Med Assoc 2020; 256:563-566. [PMID: 32068511 DOI: 10.2460/javma.256.5.563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
3
|
|
4
|
Cipolla D, Shekunov B, Blanchard J, Hickey A. Lipid-based carriers for pulmonary products: preclinical development and case studies in humans. Adv Drug Deliv Rev 2014; 75:53-80. [PMID: 24819218 DOI: 10.1016/j.addr.2014.05.001] [Citation(s) in RCA: 84] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2014] [Revised: 04/16/2014] [Accepted: 05/01/2014] [Indexed: 12/31/2022]
Abstract
A number of lipid-based technologies have been applied to pharmaceuticals to modify their drug release characteristics, and additionally, to improve the drug loading for poorly soluble drugs. These technologies, including solid-state lipid microparticles, many of which are porous in nature, liposomes, solid lipid nanoparticles and nanostructured lipid carriers, are increasingly being developed for inhalation applications. This article provides a review of the rationale for the use of these technologies in the pulmonary delivery of drugs, and summarizes the manufacturing processes and their limitations, the in vitro and in vivo performance of these systems, the safety of these lipid-based systems in the lung, and their promise for commercialization.
Collapse
Affiliation(s)
- David Cipolla
- Aradigm Corporation, 3929 Point Eden Way, Hayward, CA 94545, USA.
| | - Boris Shekunov
- Shire Corporation, 725 Chesterbrook Blvd, Wayne, PA 19087, USA
| | - Jim Blanchard
- Aradigm Corporation, 3929 Point Eden Way, Hayward, CA 94545, USA
| | - Anthony Hickey
- RTI International, 3040 Cornwallis Road, Research Triangle Park, NC 27709, USA.
| |
Collapse
|
5
|
Henderson KS, Dole V, Parker NJ, Momtsios P, Banu L, Brouillette R, Simon MA, Albers TM, Pritchett-Corning KR, Clifford CB, Shek WR. Pneumocystis carinii causes a distinctive interstitial pneumonia in immunocompetent laboratory rats that had been attributed to "rat respiratory virus". Vet Pathol 2012; 49:440-52. [PMID: 22308234 DOI: 10.1177/0300985811432351] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A prevalent and distinctive infectious interstitial pneumonia (IIP) of immunocompetent laboratory rats was suspected to be caused by a putative virus, termed rat respiratory virus, but this was never substantiated. To study this disease, 2 isolators were independently populated with rats from colonies with endemic disease, which was perpetuated by the regular addition of naive rats. After Pneumocystis was demonstrated by histopathology and polymerase chain reaction (PCR) in the lungs of rats from both isolators and an earlier bedding transmission study, the relationship between Pneumocystis and IIP was explored further by analyzing specimens from 3 contact transmission experiments, diagnostic submissions, and barrier room breeding colonies, including 1 with and 49 without IIP. Quantitative (q) PCR and immunofluorescence assay only detected Pneumocystis infection and serum antibodies in rats from experiments or colonies in which IIP was diagnosed by histopathology. In immunocompetent hosts, the Pneumocystis concentration in lungs corresponded to the severity and prevalence of IIP; seroconversion occurred when IIP developed and was followed by the concurrent clearance of Pneumocystis from lungs and resolution of disease. Experimentally infected immunodeficient RNU rats, by contrast, did not seroconvert to Pneumocystis or recover from infection. qPCR found Pneumocystis at significantly higher concentrations and much more often in lungs than in bronchial and nasal washes and failed to detect Pneumocystis in oral swabs. The sequences of a mitochondrial ribosomal large-subunit gene region for Pneumocystis from 11 distinct IIP sources were all identical to that of P. carinii. These data provide substantial evidence that P. carinii causes IIP in immunocompetent rats.
Collapse
Affiliation(s)
- K S Henderson
- Research Models and Services, Charles River, 251 Ballardvale St, Wilmington, MA 01887, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Amani A, Amini MA, Ali HSM, York P. Alternatives to conventional suspensions for pulmonary drug delivery by nebulisers: a review. J Pharm Sci 2011; 100:4563-70. [PMID: 21671227 DOI: 10.1002/jps.22665] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2011] [Revised: 04/09/2011] [Accepted: 05/24/2011] [Indexed: 01/31/2023]
Abstract
This review discusses the reports of alternative dosage forms to suspension formulations of hydrophobic drugs for nebulisers. Suspensions for nebulisers, although widely used over recent years, have several limitations which have led to pharmaceutical researchers looking for alternative, better performing preparations. Particular attention has been directed towards the use of nanoparticles as carriers of hydrophobic active ingredients. Several nanoformulations have been prepared and compared in vitro and/or in vivo with the corresponding microsuspension formulation. It is also clear that future studies in this field should address the parallel important aspects of safety and economical aspects of nanoparticualte formulations.
Collapse
Affiliation(s)
- Amir Amani
- Department of Medical Nanotechnology, School of Advanced Medical Technologies, Tehran University of Medical Sciences, Tehran 1417614411, Iran.
| | | | | | | |
Collapse
|
7
|
Whateley TL. Literature Alerts. Drug Deliv 2009. [DOI: 10.3109/10717549809031393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
8
|
Albers TM, Simon MA, Clifford CB. Histopathology of Naturally Transmitted “Rat Respiratory Virus”: Progression of Lesions and Proposed Diagnostic Criteria. Vet Pathol 2009; 46:992-9. [DOI: 10.1354/vp.08-vp-0330-c-fl] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Rat respiratory virus (RRV) is the working name for a novel respiratory pathogen of laboratory rats in North America, Europe, and Asia. Although the agent has not been definitively identified, evidence supports a viral etiology. Because no serologic or molecular assays for RRV are available, diagnosis depends on histopathologic evaluation of the lung. We introduced 104 Wistar Han rats, free of known pathogens and of RRV-associated lesions, into a rat production colony positive for RRV-type lesions, but free of other histologic, serologic, or microbiologic evidence of infectious disease. Lungs of 8 of the naïve rats were examined grossly and microscopically each week, weeks 0–13. Irregular gray-white lesions suggestive of interstitial pneumonia were grossly evident from weeks 6 through 13. Primary histopathologic evaluation of all lungs by one pathologist found multifocal, lymphohistiocytic interstitial pneumonia or prominent perivascular lymphoid cuffing from weeks 5 through 13. Based on results of the initial evaluation, diagnostic criteria for RRV infection (i.e., changes seen only after exposure to the RRV-positive colony) were tentatively selected and used by 2 other pathologists to classify each lung as RRV positive, RRV equivocal, or RRV negative. The secondary evaluation found 95% concordance in RRV diagnosis between pathologists, and correlated well with the initial evaluation, thus confirming the consistency of the criteria. These data show that RRV-naïve rats introduced into an RRV-endemic colony develop equivocal microscopic lesions of RRV by 5 weeks of exposure, and positive diagnostic lesions by 7 weeks. Interstitial pneumonia becomes grossly evident after 6 weeks of exposure.
Collapse
Affiliation(s)
- T. M. Albers
- Charles River Research Animal Diagnostic Services, Wilmington, MA
| | - M. A. Simon
- Charles River Research Animal Diagnostic Services, Wilmington, MA
| | - C. B. Clifford
- Charles River Research Animal Diagnostic Services, Wilmington, MA
| |
Collapse
|
9
|
Watts AB, Williams RO, Peters JI. Recent Developments in Drug Delivery to Prolong Allograft Survival in Lung Transplant Patients. Drug Dev Ind Pharm 2009; 35:259-71. [DOI: 10.1080/03639040802282904] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
10
|
Besselsen DG, Franklin CL, Livingston RS, Riley LK. Lurking in the shadows: emerging rodent infectious diseases. ILAR J 2009; 49:277-90. [PMID: 18506061 DOI: 10.1093/ilar.49.3.277] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
Rodent parvoviruses, Helicobacter spp., murine norovirus, and several other previously unknown infectious agents have emerged in laboratory rodents relatively recently. These agents have been discovered serendipitously or through active investigation of atypical serology results, cell culture contamination, unexpected histopathology, or previously unrecognized clinical disease syndromes. The potential research impact of these agents is not fully known. Infected rodents have demonstrated immunomodulation, tumor suppression, clinical disease (particularly in immunodeficient rodents), and histopathology. Perturbations of organismal and cellular physiology also likely occur. These agents posed unique challenges to laboratory animal resource programs once discovered; it was necessary to develop specific diagnostic assays and an understanding of their epidemiology and transmission routes before attempting eradication, and then evaluate eradication methods for efficacy. Even then management approaches varied significantly, from apathy to total exclusion, and such inconsistency has hindered the sharing and transfer of rodents among institutions, particularly for genetically modified rodent models that may not be readily available. As additional infectious agents are discovered in laboratory rodents in coming years, much of what researchers have learned from experiences with the recently identified pathogens will be applicable. This article provides an overview of the discovery, detection, and research impact of infectious agents recently identified in laboratory rodents. We also discuss emerging syndromes for which there is a suspected infectious etiology, and the unique challenges of managing newly emerging infectious agents.
Collapse
Affiliation(s)
- David G Besselsen
- University Animal Care, University of Arizona, Tucson, 1127 East Lowell Street, Tucson, AZ 85721-0101, USA.
| | | | | | | |
Collapse
|
11
|
Koshkina NV, Golunski E, Roberts LE, Gilbert BE, Knight V. Cyclosporin A Aerosol Improves the Anticancer Effect of Paclitaxel Aerosol in Mice. ACTA ACUST UNITED AC 2004; 17:7-14. [PMID: 15120008 DOI: 10.1089/089426804322994415] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The objective of this study was to assess the effect of cyclosporin A liposome aerosol on the anticancer activity of paclitaxel (PTX) liposome aerosol against renal cell carcinoma (Renca) pulmonary metastases in mice. Cyclosporin A (CsA) was administered as a liposome aerosol for one-half hour before starting one-half hour treatment with PTX liposome aerosol (CsA/PTX), and in a second groups of animals cyclosporin A liposome aerosol was given before PTX for one-half hour and also later by mixing a second dose of cyclosporin A aerosol with PTX aerosol and extending the treatment period to one hour (CsA/PTX + CsA). In one experiment, PTX and CsA/PTX aerosols were significantly more effective compared to untreated controls against renal cell cancer as measured by lung weights and tumor surface areas. CsA/PTX was significantly better that PTX alone as measured by lung weights and tumor area. In a second experiment, tumor areas of PTX and CsA/PTX treated mice were significantly reduced compared to untreated controls and CsA/PTX treated mice had significantly smaller tumor areas than PTX treated mice. In contrast, tumor numbers were not significantly fewer than controls in either therapeutic group. In a third experiment, tumor numbers and tumor areas were significantly fewer in mice treated with CsA/PTX and CsA/PTX + CsA compared to untreated controls. Mice treated with CsA/PTX + CsA had significantly fewer tumors and less tumor area than mice receiving CsA/PTX. While PTX treated mice were not different than untreated controls with respect to tumor numbers or tumor volumes, PTX treated mice had significantly greater tumor numbers and tumor areas than CsA/PTX and CsA/PTX + CsA treated mice. Co-administration of CsA with PTX demonstrated significant dose dependent anticancer effects against renal cell pulmonary metastases in mice. Toxicity manifested by weight loss was associated with the highest dose of CsA.
Collapse
Affiliation(s)
- Nadezhda V Koshkina
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, One Baylor Plaza, Houston, TX 77030, USA
| | | | | | | | | |
Collapse
|
12
|
Knight V, Kleinerman ES, Waldrep JC, Giovanella BC, Gilbert BE, Koshkina NV. 9-Nitrocamptothecin liposome aerosol treatment of human cancer subcutaneous xenografts and pulmonary cancer metastases in mice. Ann N Y Acad Sci 2001; 922:151-63. [PMID: 11193890 DOI: 10.1111/j.1749-6632.2000.tb07033.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The purpose of this study was to test the anticancer properties of the water-insoluble derivative of camptothecin, 9-nitrocamptothecin (9NC), administered in a liposome formulation (L-9NC) in aerosol to mice with subcutaneous xenografts of three human cancers and in mice with murine melanoma and human osteosarcoma pulmonary metastases. The drug was formulated with dilauroylphosphatidylcholine and nebulized in particle sizes of 1.2-1.6 microns mass median aerodynamic diameter and a geometric standard deviation of 2.0. The aerosol was generated with the nebulizer flowing at 10 l/min and delivered to mice in sealed plastic cages or in a nose-only exposure chamber. Aerosol was administered for 15 min to 2 hr daily, delivering deposited doses in the respiratory tract of 8.1-306.7 micrograms of 9NC/kg. With subcutaneous tumors, growth was greatly inhibited or tumors were undetectable after several weeks of treatment. We also showed that oral dosage with L-9NC had no detectable effect on cancer growth, and thus the benefit from aerosol treatment was due to pulmonary deposition and not the larger fraction of drug deposited in the nose of mice during aerosol treatment which is promptly swallowed. Intramuscular L-9NC in slightly larger doses than given in the aerosol had detectable anticancer activity, but it was significantly less than in mice receiving the drug by aerosol. With metastatic pulmonary cancers, treated animals showed highly significantly less cancer growth than control animals. L-9NC aerosol showed a major therapeutic benefit in the treatment of subcutaneous human cancer xenografts in nude mice, suggesting that cancers at systemic sites might be responsive to this treatment. In addition, the strong anticancer effect of L-9NC aerosol on pulmonary metastases offers a therapeutic approach for treatment of pulmonary cancers. Thus, L-9NC aerosol may have applicability in the treatment of cancers throughout the body.
Collapse
Affiliation(s)
- V Knight
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, One Baylor Plaza, Houston, TX 77030, USA
| | | | | | | | | | | |
Collapse
|
13
|
Klyashchitsky BA, Owen AJ. Nebulizer-compatible liquid formulations for aerosol pulmonary delivery of hydrophobic drugs: glucocorticoids and cyclosporine. J Drug Target 2000; 7:79-99. [PMID: 10617295 DOI: 10.3109/10611869909085494] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
This review discusses pulmonary delivery of glucocorticoids and cyclosporine in pharmaceutically acceptable organic solvents and liposomes, as well as in micellar solutions and microemulsions, by means of liquid aerosols generated by nebulizers. The review points out the importance of a variety of parameters for successful treatment of immunologically mediated lung diseases by inhalation of drug containing aerosols with particular references to physico-chemical properties of formulations, aerosol parameters, pharmacokinetics, and lung deposition in experimental animals and humans. The prospects for the use of these types of formulations for clinical treatment of asthma, lung transplant rejection processes and other lung diseases are summarized.
Collapse
|
14
|
Waldrep J, Arppe J, Jansa K, Vidgren M. Experimental pulmonary delivery of cyclosporin A by liposome aerosol. Int J Pharm 1998. [DOI: 10.1016/s0378-5173(97)00322-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
15
|
Gilbert BE, Knight C, Alvarez FG, Waldrep C, Rodarte JR, Knight V, Eschenbacher WL. Tolerance of volunteers to cyclosporine A-dilauroylphosphatidylcholine liposome aerosol. Am J Respir Crit Care Med 1997; 156:1789-93. [PMID: 9412556 DOI: 10.1164/ajrccm.156.6.9702101] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Cyclosporine A (CsA) in liposomes of dilauroylphosphatidylcholine (DLPC), containing 118 micrograms of CsA/L of aerosol with a particle size of 1.6 to 1.7 micron diameter, was inhaled by 10 nonsmoking, normal volunteers each for 45 min. Aerosol was administered through an Aerotech II nebulizer (CIS-US, Inc., Bedford, MA) mouthpiece. Eight of the 10 volunteers had tracheal irritation and intermittent coughing following exposure. FEV1 and FVC values were mildly reduced, but returned to normal in 1 h. Blood chemical and hematologic values were unchanged at any time point after as opposed to before inhalation. Nine of the 10 volunteers later inhaled DLPC only, administered through the nebulizer mouthpiece. There was no change in FEV1 or FVC values, and there was no coughing or tracheal irritation. Subsequently, five of the volunteers who had previously had respiratory reactions inhaled CsA-DLPC liposome aerosol for 45-min, but through a mouth-only face mask. There was no tracheal irritation, coughing, or changes in spirometric measures. Blood concentrations of CsA at 15 min after the 45-min inhalation with a face mask averaged 83 +/- 42 ng/ml (mean +/- SD). At 24 h after treatment, CsA was undetectable in blood of the initial 10 volunteers. These studies indicate that CsA-DLPC liposome aerosol can be safely explored as a treatment for patients with moderately severe asthma.
Collapse
Affiliation(s)
- B E Gilbert
- Department of Microbiology and Immunology, Baylor College of Medicine, Houston, Texas 77030, USA
| | | | | | | | | | | | | |
Collapse
|