1
|
Ozdemir M, Akkoc MF, Selçuk CT, Erbatur S. Effectiveness of reverse first dorsal metatarsal artery flap for reconstruction of distal foot in electrical injuries. Burns 2025; 51:107335. [PMID: 39721242 DOI: 10.1016/j.burns.2024.107335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2024] [Revised: 11/09/2024] [Accepted: 11/23/2024] [Indexed: 12/28/2024]
Abstract
INTRODUCTION The severity of electrical injuries depends on the voltage, the duration of exposure to current, and the trajectory of the current through the body. The reconstruction for defects caused by electric current is a difficult process. OBJECTIVE The purpose of this study is to investigate the effectiveness of the reverse first dorsal metatarsal artery (FDMA) flap in the reconstruction of distal foot injuries caused by electric currents. METHOD This is an observational and descriptive study. Reverse FDMA flaps were used in 21 patients with defects in the distal of their feet as a consequence of electrical injuries, and their outcomes were observed. Descriptive statistical methods were used in the analyses of the data. RESULTS While 57.1 % of the patients were between 18 and 35 years old, 3 patients were children, and 81 % of the patients were male. The site of the defect was the right sole/dorsum in 33.4 % of the cases and the right great toe in 28.6 %. Twenty patients (95.6 %) were exposed to high-voltage electric current. The dimensions of the defects of 42.9 % of the patients were 5-8 cm × 2-4 cm. Wound dehiscence was seen in 1 diabetic patient, and superficial flap necrosis developed in a young male patient with no health problems other than his electrical injury. Angiography was not performed on any patient. CONCLUSION The reverse FDMA flap is a safe and effective method for the reconstruction for electrical injuries developing in the distal foot in which one-stage surgery is sufficient. We recommend the usage of the reverse FDMA flap for the closure of soft tissue defects caused by electrical injury in the sole, dorsal region of the foot, and great toes.
Collapse
Affiliation(s)
- Mehmet Ozdemir
- Department of Plastic Reconstructive and Aesthetic Surgery, Kanuni Sultan Suleyman Training and Research Hospital, Istanbul, Turkey
| | - Mehmet Fatih Akkoc
- Department of Plastic Reconstructive and Aesthetic Surgery, Faculty of Medicine, Dicle University, Diyarbakir, Turkey.
| | - Caferi Tayyar Selçuk
- Department of Plastic Reconstructive and Aesthetic Surgery, Faculty of Medicine, Dicle University, Diyarbakir, Turkey
| | - Serkan Erbatur
- Department of Plastic Reconstructive and Aesthetic Surgery, Faculty of Medicine, Dicle University, Diyarbakir, Turkey
| |
Collapse
|
2
|
Campos JL, Suominen S, Pons G, Al-Sakkaf AM, Lusetti IL, Sirota M, Vela FJ, Pires L, Sánchez-Margallo FM, Abellán E, Masiá J. Lymphatic Patterns in the Superficial Circumflex Iliac Artery Perforator Flap. J Reconstr Microsurg 2025; 41:209-218. [PMID: 38848754 PMCID: PMC11825209 DOI: 10.1055/a-2340-9629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/22/2024] [Indexed: 06/09/2024]
Abstract
BACKGROUND Lymphedema is a chronic condition, characterized by fluid buildup and tissue swelling and is caused by impairment of the lymphatic system. The lymph interpositional flap transfer technique, in which lymph flow is restored with a flap that includes subdermal lymphatic channels, is an option for surgical reconstruction. The superficial circumflex iliac artery perforator (SCIP) flap can be used for this purpose. This study aimed to describe and characterize the lymphatic patterns within the vascular territory of the SCIP flap. METHODS This cross-sectional multicenter study involved 19 healthy volunteers aged ≥18 years of both sexes assessing the bilateral SCIP flap zone. Superficial lymphatic patterns were evaluated at 4-, 14-, and 24 minutes after indocyanine green (ICG) lymphography injection. Standardized procedures were implemented for all participants in both hospitals. RESULTS The linear pattern was predominant bilaterally. The median number of lymphatic vessels and their length increased over time. Most lymphatic vessels in the SCIP flap were oriented toward the inguinal lymph node (ILN). However, the left SCIP zone lymphatic vessels were directed opposite to the ILN. CONCLUSION The two sides SCIP zones were not significantly different. The primary direction of the bilateral lymphatic vessels was toward the ILN, although only single-side lymphatic vessels were in the opposite direction. These findings emphasize the importance of assessing lymphatic axiality and coherent lymphatic patterns prior to undertaking the SCIP as an interposition flap, to ensure effective restoration of lymphatic flow.
Collapse
Affiliation(s)
- José Luis Campos
- Department of Microsurgery, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Spain
| | - Sinikka Suominen
- Department of Plastic and Reconstructive Surgery, Helsinki University Central Hospital, Helsinki, Finland
| | - Gemma Pons
- Department of Plastic Surgery, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Ali M. Al-Sakkaf
- Department of Plastic Surgery, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Irene Laura Lusetti
- Department of Plastic Surgery, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Max Sirota
- Department of Plastic Surgery, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Francisco Javier Vela
- Department of Microsurgery, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Spain
| | - Laura Pires
- Department of Microsurgery, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Spain
| | | | - Elena Abellán
- Department of Microsurgery, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Spain
| | - Jaume Masiá
- Department of Plastic Surgery, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| |
Collapse
|
3
|
Dong W, Xiao X, Wang Z, Yang X, Bi H. Superficial circumflex iliac artery perforator propeller flap for penoscrotal extramammary Paget's disease. Int J Dermatol 2025; 64:142-148. [PMID: 39010187 DOI: 10.1111/ijd.17325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 03/24/2024] [Accepted: 05/29/2024] [Indexed: 07/17/2024]
Abstract
BACKGROUND Extramammary Paget's disease (EMPD) is a rare intra-epidermal adenocarcinoma, and reconstruction of the penoscrotal region remains a clinical challenge. The superficial circumflex iliac artery perforator (SCIP) flap has been successfully used as a free flap, while its application as a propeller flap in the reconstruction of penoscrotal EMPD defect is rarely reported. The objective was to evaluate the safety and efficacy of the SCIP propeller flap in the reconstruction of penoscrotal defects in EMPD. METHODS Between September 2010 and August 2022, consecutive patients diagnosed with penoscrotal EMPD were enrolled. All patients underwent penoscrotal EMPD excision and reconstruction with SCIP propeller flap combined with other flaps or skin grafts on individual defects. Demographic information, surgical parameters, postoperative complications, patient satisfaction, and recurrence rates were analyzed. RESULTS Twenty-four patients (mean age, 73 ± 8.8 years; mean BMI, 23.98 ± 3.62 kg/m2) with 33 SCIP propeller flaps (mean size 120.1 cm2; range, 24-208 cm2) were included, and the mean defect size was 67.4 cm2 (range, 12-255 cm2). The mean operative duration was 385.4 ± 146.8 min. Fifteen patients received autologous full-thickness skin grafts, and four received other flaps simultaneously. All flaps survived without total or partial loss, and all donor sites achieved primary closure, though local hematoma (one case) and limited skin graft necrosis (two cases) were observed. All patients experienced complete wound healing and maintained penoscrotal morphology and function without recurrent lesions over a mean follow-up of 59 months. CONCLUSIONS The SCIP propeller flap seems a safe and effective reconstructive method for penoscrotal EMPD. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Wenfang Dong
- Department of Plastic and Reconstructive Surgery, Peking University Third Hospital, Beijing, China
| | - Xiaodi Xiao
- Department of Plastic and Reconstructive Surgery, Peking University Third Hospital, Beijing, China
| | - Zheng Wang
- Department of Plastic and Reconstructive Surgery, Peking University Third Hospital, Beijing, China
| | - Xin Yang
- Department of Plastic and Reconstructive Surgery, Peking University Third Hospital, Beijing, China
| | - Hongsen Bi
- Department of Plastic and Reconstructive Surgery, Peking University Third Hospital, Beijing, China
| |
Collapse
|
4
|
Pan Z, Zhao Y, Ye X, Wang J, Li X. Surgical refinements and sensory and functional outcomes of using thinned sensate anterolateral thigh perforator flaps for foot and ankle reconstruction: A retrospective study. Medicine (Baltimore) 2024; 103:e38763. [PMID: 39287244 PMCID: PMC11404924 DOI: 10.1097/md.0000000000038763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Revised: 03/30/2024] [Accepted: 06/10/2024] [Indexed: 09/19/2024] Open
Abstract
To improve the use of sensate anterolateral thigh (ALT) flaps for foot and ankle reconstruction, we employed a thinned nerve-selective harvesting technique. The data of 31 patients in whom sensate ALT perforator flaps were transferred for reconstruction of soft-tissue defects in the foot and ankle were reviewed. Flaps were elevated with 2 refinements. The first is the initial selection of the "true" sensory branch in the medial incision on the suprafascial plane. The second is flap thinning by keeping a cuff of thin deep fat surrounding the point where the perforator or nerve branch inserts into the superficial fat layer. The recipient site assessment consisted of complications, monofilament touch perception, sharp-blunt discrimination, axial circumference, and American Orthopedic Foot and Ankle Society score. After a mean follow-up of 31.7 months, all flaps survived uneventfully, except for marginal necrosis in 1 patient, infection in 1 patient, ulceration in 2 patients, and secondary thinning in 3 patients. The sensation of each flap was restored. A total of 87% and 90% of the patients exhibited 5 or more positive response points in the Semmes-Weinstein monofilament touch and sharp-blunt discrimination testings, respectively. The mean axial circumference of the reconstructed foot was 27.4 cm (the unaffected side was 25.8 cm). All patients achieved mobility in ordinary shoes with a mean functional score of 74.6. The thinned nerve-selective sensate ALT perforator flap can be a favorable option for foot and ankle reconstruction. This method also offers the possibility of preserving the nerve branch at the donor thigh.
Collapse
Affiliation(s)
- ZhaoHui Pan
- Institute of Orthopedic Trauma Surgery of the Chinese People’s Liberation Army, 80th Group Military Hospital, Weifang, China
| | - YuXiang Zhao
- Institute of Orthopedic Trauma Surgery of the Chinese People’s Liberation Army, 80th Group Military Hospital, Weifang, China
| | - XingHua Ye
- Institute of Orthopedic Trauma Surgery of the Chinese People’s Liberation Army, 80th Group Military Hospital, Weifang, China
| | - JianBo Wang
- Institute of Orthopedic Trauma Surgery of the Chinese People’s Liberation Army, 80th Group Military Hospital, Weifang, China
| | - XingBo Li
- Institute of Orthopedic Trauma Surgery of the Chinese People’s Liberation Army, 80th Group Military Hospital, Weifang, China
| |
Collapse
|
5
|
Zhang Y, Zeng A. An Easy Way to Harvest a Superthin SCIP Flap with Long Pedicle: Reappraisal of the Inferolateral Branches of the SCIA. Plast Reconstr Surg 2023; 152:1100-1104. [PMID: 36862953 DOI: 10.1097/prs.0000000000010338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
SUMMARY Despite being the first free flap used in reconstructive surgery, the groin flap slowly fell out of fashion because of its short pedicle length, small vessel diameter, variable vascular anatomy, and bulkiness. Over the years, the authors have found that perforators consistently exist inferolateral to the deep branch of the superficial circumflex iliac artery (SCIA), forming an F configuration with the main branch. The authors propose a new type of superficial circumflex iliac artery perforator (SCIP) flap design based on the perforators derived from these inferolateral branches of the SCIA. These perforators have the advantage of anatomic consistency and can be easily found by making an exploratory incision 2 cm caudal to the inguinal ligament. The perforators of the inferolateral branches extend directly into the dermal plexus, and thus can yield superthin flaps without microdissection defatting. Retrograde dissection allows the surgeon to elongate the pedicle to include a section or full length of the SCIA as needed and involving minimal muscle dissection. SCIP flaps harvested based on the perforators of the inferolateral branches of the SCIA were used successfully for six head and neck reconstructions and two trunk reconstructions with no major complications, including flap loss or lymphedema. The best indications for SCIP flaps based on the inferolateral branches of the SCIA are superficial soft-tissue defects that do not require much volume replacement.
Collapse
Affiliation(s)
- Yuwei Zhang
- From the Department of Plastic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences
| | - Ang Zeng
- From the Department of Plastic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences
| |
Collapse
|
6
|
Besmens IS, Zoller FE, Guidi M, Giovanoli P, Calcagni M. How to measure success in lower extremity reconstruction, which outcome measurements do we use a systematic review and metanalysis. J Plast Surg Hand Surg 2023; 57:505-532. [PMID: 36779747 DOI: 10.1080/2000656x.2023.2168274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
Different factors have to be considered and weighted in the treatment algorithm of lower extremity reconstruction. A combination of both clinicians' and patients' perspectives is necessary to provide a conclusive picture. Currently, there aren't any standardized and validated measurement data sets for lower extremity reconstructions. This makes it necessary to identify the relevant domains. We, therefore, performed a systematic review and metanalysis of outcome measurements and evaluated their ability to measure outcomes after lower extremity reconstruction. A systematic review and metanalysis according to the 'Preferred Reporting Items for Systematic Reviews and Meta-Analyses' protocol were performed for studies reporting at least one structured outcome measurement of lower extremity reconstruction. Both Patient (PROMs)- and Clinician reported outcome measurements (CROMs)were analyzed. Of the 2827 identified articles, 102 were included in the final analysis. In total 86 outcome measurements were identified, 34 CROMs, 44 PROMs and 8 (9.3%) outcome measurements that have elements of both. Twenty-four measure functional outcome, 3 pain, 10 sensations and proprioception, 9 quality of life, 8 satisfaction with the result, 5 measure the aesthetic outcome, 6 contours and flap stability and 21 contain multidomain elements. A multitude of different outcome measurements is currently used in lower extremity reconstruction So far, no consensus has been reached on what to measure and how. Validation and standardization of both PROMs and CROMs in plastic surgery is needed to improve the outcome of our patients, better meet their needs and expectations and eventually optimize extremity reconstruction by enabling a direct comparison of studies' results.
Collapse
Affiliation(s)
- Inga S Besmens
- Department of Plastic Surgery and Hand Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Florence E Zoller
- Department of Plastic Surgery and Hand Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Marco Guidi
- Department of Plastic Surgery and Hand Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Pietro Giovanoli
- Department of Plastic Surgery and Hand Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Maurizio Calcagni
- Department of Plastic Surgery and Hand Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
7
|
Fuse Y, Yamamoto T, Kageyama T, Sakai H, Tsukuura R, Yoshimatsu H, Yamamoto N. Domino Free Flap Transfer Using a Superficial Circumflex Iliac Artery Perforator Flap for the Toe Flap Donor Site. Ann Plast Surg 2022; 88:293-297. [PMID: 34225310 DOI: 10.1097/sap.0000000000002948] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Toe-to-hand transfer is a favorable option for finger reconstruction, but donor site healing can be challenging. The superficial circumflex iliac artery perforator (SCIP) flap has yet to be used widely for toe reconstruction. The purpose of this report was to validate the efficacy of the sequential simultaneous free SCIP flap transfer for the toe flap donor site in a consecutive case series. METHODS The medical records of 18 consecutive patients who underwent a simultaneous SCIP flap transfer and a toe-to-hand transplant were reviewed. Free SCIP flap reconstruction was performed in a simultaneous 2-team approach. The SCIP flaps were transferred to various toe flap donor sites: a great toe wraparound flap in 9 cases, a second toe distal phalangeal flap in 4 cases, a great toe osteo-onycho-cutaneous flap in 3 cases, a twisted wraparound flap in 1 case, and a great toe hemipulp flap in 1 case. RESULTS The size of the SCIP flap ranged from 5 × 3 to 16 × 8 cm. A mean of the total operative time was 229.2 minutes (range, 118-441 minutes; SD, 75.8 minutes). All the SCIP and toe flaps survived completely. Minor wound dehiscence was seen in 2 cases, and the wound healed by conservative treatment. The mean follow-up period was 23.7 months (range, 7-44 months; SD, 9.7 months). No patient had gait dysfunction postoperatively. CONCLUSIONS A sequential SCIP flap transfer was performed simultaneously without additional time, allowing secure soft tissue coverage of the toe flap donor even with avascular tissue such as bone or tendon exposed. The sequential SCIP flap transfer can be a useful option for reconstruction of toe flap donor site, when multiple microsurgeons and microscopes are available.
Collapse
Affiliation(s)
| | | | - Takashi Kageyama
- From the Department of Plastic and Reconstructive Surgery, National Center for Global Health and Medicine
| | - Hayahito Sakai
- From the Department of Plastic and Reconstructive Surgery, National Center for Global Health and Medicine
| | - Reiko Tsukuura
- From the Department of Plastic and Reconstructive Surgery, National Center for Global Health and Medicine
| | - Hidehiko Yoshimatsu
- Department of Plastic and Reconstructive Surgery, Cancer Institute Hospital of Japanese Foundation for Cancer Research
| | | |
Collapse
|
8
|
Kelahmetoglu O, Mehdizade T, Unal M, Keles MK, Guneren E. Free ALT Perforator Flap in Nonobese Patients: The Recontouring of Soft Tissue Defects Around Foot. Indian J Orthop 2021; 56:445-451. [PMID: 35251508 PMCID: PMC8854467 DOI: 10.1007/s43465-021-00518-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 09/04/2021] [Indexed: 02/04/2023]
Abstract
BACKGROUND The anterolateral thigh (ALT) perforator flap is well-described and versatile option for reconstruction of soft tissue defects around foot and ankle. This retrospective review was performed for reconstruction of soft tissue defects around foot with ALT perforator flaps in patients with normal and overweight body mass index (BMI). METHODS Between January 2016 and November 2020, ALT flaps were used in 30 patients for foot defects. RESULTS Etiologic factors were trauma (18 patients), diabetic foot ulcer (6 patients), tumor (3 patients), infection (2 patients) and burn contracture (1 patient). Mean body mass index (BMI) value was 24.9 ± 4.1 (17-30). Mean flap dimension was 145 ± 86 (40-420) cm2. Recipient vessels were anterior tibial artery in 17 patients (56%), posterior tibial artery in 12 patients (40%), reversed flow dorsalis pedis artery in 1 patient (3.3%). In 24 patients (80%), 2 vein anastomoses were done. Debulking were applied in two patients (6.6%). Donor area was grafted in four patients (13.3%). Mean flap score was 1.25 ± 0.5. Mean flap thickness was 10 ± 2 (7-14) mm. Visual Analogue Scale (VAS) score was 7.75 ± 1.04 (6-10). The patients were followed up for a mean of 14 ± 11 (1-30) months. CONCLUSION We think that ALT flap is still reliable and precious option because it provides ideal soft tissue reconstruction by means of recontouring of foot in nonobese patients.
Collapse
Affiliation(s)
- Osman Kelahmetoglu
- Department of Plastic, Reconstructive and Aesthetic Surgery, Faculty of Medicine, Yeditepe University, Istanbul, Turkey
| | - Turan Mehdizade
- Department of Plastic, Reconstructive and Aesthetic Surgery, Bezmialem Vakif University, Istanbul, Turkey
| | - Mustafa Unal
- Department of Plastic, Reconstructive and Aesthetic Surgery, Bezmialem Vakif University, Istanbul, Turkey
| | | | - Ethem Guneren
- Department of Plastic, Reconstructive and Aesthetic Surgery, Bezmialem Vakif University, Istanbul, Turkey
| |
Collapse
|
9
|
Schiltz D, Lenhard J, Klein S, Anker A, Lonic D, Heidekrueger PI, Prantl L, Jung EM, Platz Batista Da Silva N, Kehrer A. Do-It-Yourself Preoperative High-Resolution Ultrasound-Guided Flap Design of the Superficial Circumflex Iliac Artery Perforator Flap (SCIP). J Clin Med 2021; 10:jcm10112427. [PMID: 34070779 PMCID: PMC8198546 DOI: 10.3390/jcm10112427] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 05/18/2021] [Accepted: 05/26/2021] [Indexed: 11/21/2022] Open
Abstract
The superficial circumflex iliac artery perforator (SCIP) flap is a well-documented, thin, free tissue flap with a minimal donor site morbidity, and has the potential to become the new method for resurfacing moderate-size skin defects. The aim of this study is to describe an easy, reliable, systematic, and standardized approach for preoperative SCIP flap design and perforator characterization, using color-coded duplex sonography (CCDS). A list of customized settings and a straightforward algorithm are presented, which are easily applied by an operator with minimal experience. Specific settings for SCIP flap perforator evaluation were investigated and tested on 12 patients. Deep and superficial superficial circumflex iliac artery (SCIA) branches, along with their corresponding perforators and cutaneous veins, were marked individually with a permanent marker and the anatomy was verified intraoperatively. From this, a simplified procedure for preoperative flap design of the SCIP flap was developed. Branches could be localized and evaluated in all patients. A preoperative structured procedure for ultrasonically guided flap design of the SCIP flap is described. A 100% correlation between the number and emergence points of the branches detected by preoperative CCDS mapping and the intraoperative anatomy was found.
Collapse
Affiliation(s)
- Daniel Schiltz
- Department of Plastic and Aesthetic Surgery, Hand Surgery, Helios Hospital Emil von Behring, 14165 Berlin, Germany;
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (J.L.); (S.K.); (A.A.); (D.L.); (P.I.H.); (L.P.)
| | - Jasmin Lenhard
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (J.L.); (S.K.); (A.A.); (D.L.); (P.I.H.); (L.P.)
| | - Silvan Klein
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (J.L.); (S.K.); (A.A.); (D.L.); (P.I.H.); (L.P.)
| | - Alexandra Anker
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (J.L.); (S.K.); (A.A.); (D.L.); (P.I.H.); (L.P.)
| | - Daniel Lonic
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (J.L.); (S.K.); (A.A.); (D.L.); (P.I.H.); (L.P.)
| | - Paul I. Heidekrueger
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (J.L.); (S.K.); (A.A.); (D.L.); (P.I.H.); (L.P.)
| | - Lukas Prantl
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (J.L.); (S.K.); (A.A.); (D.L.); (P.I.H.); (L.P.)
| | - Ernst-Michael Jung
- Department of Radiology, University Medical Center Regensburg, 93053 Regensburg, Germany; (E.-M.J.); (N.P.B.D.S.)
| | | | - Andreas Kehrer
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (J.L.); (S.K.); (A.A.); (D.L.); (P.I.H.); (L.P.)
- Correspondence: ; Tel.: +49-941-9446763
| |
Collapse
|
10
|
Zubler C, Haberthür D, Hlushchuk R, Djonov V, Constantinescu MA, Olariu R. The anatomical reliability of the superficial circumflex iliac artery perforator (SCIP) flap. Ann Anat 2020; 234:151624. [PMID: 33129977 DOI: 10.1016/j.aanat.2020.151624] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Revised: 08/23/2020] [Accepted: 10/12/2020] [Indexed: 12/31/2022]
Abstract
INTRODUCTION In order to achieve a satisfactory functional and aesthetic result a thin skin flap is often required in surgical reconstruction of various body regions. Perforator flaps based on either the superficial or deep branch of the superficial circumflex iliac artery (SCIA) have been used for this purpose mainly in the Asian population. Recently the superficial plane has been established as a new way of elevating the flap. Anatomical studies and details of this new flap are lacking. MATERIAL AND METHODS Wide areas were harvested subfascially from the groin of Thiel-fixated cadavers. Both deep and superficial branches of the superficial circumflex iliac artery were carefully dissected and individually injected with μAngiofil. After CT-imaging the flaps were raised on the superficial plane, perforators were marked and the flaps subsequently rescanned. High-resolution images of regions of interest were taken using micro-CT. RESULTS A total of 21 flaps were harvested and analyzed. Both the deep and superficial branch provided more than three perforators per branch, however, the deep branch based flap was significantly larger (202 vs. 112 cm2, p < 0.01) and had a longer pedicle (9.1 vs. 6.6 cm, p < 0.01). Raising the flap in the superficial plane reliably reduces bulk and increases homogeneity. CONCLUSIONS The SCIP flap appears to have a reliable vascular blood supply. The SCIA and its main branches and perforators have a consistent vascular pattern. The deep branch of the SCIA has the anatomic potential to be the preferred pedicle in case larger flaps with longer pedicles are necessary.
Collapse
Affiliation(s)
- Cédric Zubler
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland; Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, Freiburgstrasse, 3010 Bern, Switzerland
| | - David Haberthür
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
| | - Ruslan Hlushchuk
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
| | - Valentin Djonov
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
| | - Mihai A Constantinescu
- Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, Freiburgstrasse, 3010 Bern, Switzerland
| | - Radu Olariu
- Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, Freiburgstrasse, 3010 Bern, Switzerland.
| |
Collapse
|
11
|
Li Z, Zheng D, Zheng J, Qi W, Qi Q, Liu Y. Free superficial circumflex iliac artery perforator flap with a single-pedicle bilobed design for pediatric multi-digit defect reconstruction. J Orthop Surg Res 2020; 15:216. [PMID: 32527269 PMCID: PMC7291421 DOI: 10.1186/s13018-020-01733-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 05/27/2020] [Indexed: 11/10/2022] Open
Abstract
Objectives This paper describes imaging and anatomical features, in order to assess the feasibility of superficial circumflex iliac artery perforator (SCIP) flap with a single-pedicle bilobed design for multi-digit skin and soft tissue reconstruction in pediatric patients. Methods A total of 7 pediatric patients who were being treated with free single-pedicle bilobed SCIP flap reconstruction for multi-digit defects were included in this study. The details of the clinical features were collected, and the following were successively analyzed: the preoperative computed tomographic angiography (CTA) and color Doppler sonography (CDS) examinations for flap design, the intraoperative anatomy for perforator vessel, defect reconstruction and interphalangeal range of motion (ROM) and tactile sense, pain sense, and two-point discrimination recovery results. Results CTA and CDS performed preoperatively could accurately and rapidly identify the position, location and course of the superficial circumflex iliac artery perforator. All wounds healed by the first follow-up and no complications occurred at the follow-up visit. All flaps survived, the patients achieved proximal interphalangeal joint (PIP) ranges of motions (ROM) from 80 to 100° and distal interphalangeal joint (DIP) ROM from 65 to 80°. The tactile sense and pain sense recovered, and average of the two-point discrimination scores was 9.3 mm (range 7–12 mm). The donor area was primarily sutured with a tidy scar in the underwear region. Conclusion CTA and CDS performed preoperatively are accurate and intuitive methods for assessing the location and course of SCIP. The SCIP flap is suitable for pediatric patients due to its small vessel caliber, specific functional and esthetic benefits. It can be designed in a lobulated fashion in order to repair two or more wounds during one surgery. We suggest that the free single-pedicle bilobed SCIP flap should be considered a good option choice for multi-digit defect reconstruction in pediatric patients in the clinic.
Collapse
Affiliation(s)
- Zhangcan Li
- Department of Hand Microsurgery, Xuzhou Renci Hospital, No. 11 Yangshan Road, Xuzhou, 221004, Jiangsu, China
| | - Dawei Zheng
- Department of Hand Microsurgery, Xuzhou Renci Hospital, No. 11 Yangshan Road, Xuzhou, 221004, Jiangsu, China.
| | - Jian Zheng
- Department of Hand Microsurgery, Xuzhou Renci Hospital, No. 11 Yangshan Road, Xuzhou, 221004, Jiangsu, China
| | - Weiya Qi
- Department of Hand Microsurgery, Xuzhou Renci Hospital, No. 11 Yangshan Road, Xuzhou, 221004, Jiangsu, China
| | - Qiang Qi
- Department of Hand Microsurgery, Xuzhou Renci Hospital, No. 11 Yangshan Road, Xuzhou, 221004, Jiangsu, China
| | - Yunyun Liu
- Department of Gynecology, Xuzhou Maternal & Child Health Care Hospital, Xuzhou, 221009, Jiangsu, China
| |
Collapse
|
12
|
Liu S, Tan J, Tao S, Duan Y, Hu X, Li Z. Reconstruction of a Distal Foot Skin Defect Using an Intermediate Dorsal Neurocutaneous Flap. Orthop Surg 2020; 12:442-449. [PMID: 32048450 PMCID: PMC7189044 DOI: 10.1111/os.12623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Revised: 11/27/2019] [Accepted: 12/30/2019] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE To present the use of an intermediate dorsal neurocutaneous flap for the reconstruction of defects on the distal foot. METHODS From September 2016 to October 2018, five patients (mean age at operation 33.8 years; range, 7-70 years; female/male = 2/3) with skin defects on one of their feet caused by road-traffic accidents, electrical injury, and syndactyly correction were retrospectively reviewed. The size of the defects ranged from 2.0 cm × 1.0 cm to 5.0 cm × 3.5 cm. All patients had undergone a reconstruction surgery using intermediate dorsal neurocutaneous flap. One patient underwent a syndactyly correction, and four patients first experienced aggressive debridement. The sizes of the flaps were between 5.0 cm × 2.0 cm and 6.0 cm × 4.0 cm. The function, appearance, and pain of the injured foot were assessed using the Chinese Manchester Foot Pain and Disability Index and visual analogue scale. RESULTS These five patients were systematically followed up for a mean of 15.8 months (range, 12-20 months). The donor sites were closed primarily in two cases, and skin grafts were performed in three cases. All the flaps survived with a success rate of 100%; the wounds healed well, and the color matches were excellent. Partial superficial flap necrosis occurred in one of five flaps, which was treated by dressing change using a hypertonic saline gauze. No significant problems were found at the donor site in any patient immediately afterwards or at follow-up. There were no problems in any patients associated with wearing shoes. Based on the Chinese Manchester Foot Pain and Disability Index, four patients were strongly satisfied and one was satisfied with the recovery of physical function; all the patients were strongly satisfied with the appearance of the injured foot; all five patients had an excellent score of pain intensity subscale. Except for one patient who reported mild pain, all the other patients reported no pain based on the visual analogue scale. Two typical cases are presented in this paper. CONCLUSIONS The intermediate dorsal neurocutaneous flap is an alternative and effective technique that can reliably cover minor- to medium-sized defects on the distal foot, toes, and web spaces. This surgical method leads to satisfactory functional recovery with minimal donor site morbidity, and no major vessels need to be sacrificed. This procedure offers an advisable option for orthopaedic surgeons to treat defects on the distal foot.
Collapse
Affiliation(s)
- Siyi Liu
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, Wuhan City, Hubei Province, China
| | - Jinhai Tan
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, Wuhan City, Hubei Province, China
| | - Shengxiang Tao
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, Wuhan City, Hubei Province, China
| | - Yong Duan
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, Wuhan City, Hubei Province, China
| | - Xiang Hu
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, Wuhan City, Hubei Province, China
| | - Zonghuan Li
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, Wuhan City, Hubei Province, China
| |
Collapse
|
13
|
Boissière F, Luca-Pozner V, Vaysse C, Kerfant N, Herlin C, Chaput B. The SCIP propeller flap: Versatility for reconstruction of locoregional defect✰. J Plast Reconstr Aesthet Surg 2019; 72:1121-1128. [DOI: 10.1016/j.bjps.2019.03.016] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2019] [Accepted: 03/10/2019] [Indexed: 10/27/2022]
|
14
|
Hayashida K, Yamakawa S, Saijo H, Fujioka M. Foot reconstruction with the superficial circumflex iliac artery perforator flap under local anesthesia: Two case reports. Medicine (Baltimore) 2019; 98:e13888. [PMID: 30633161 PMCID: PMC6336647 DOI: 10.1097/md.0000000000013888] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
RATIONALE The superficial circumflex iliac artery perforator (SCIP) free flap is a popular method used in foot reconstruction. Although the SCIP flap has a relatively short pedicle and does not require intramuscular dissection, general anesthesia is largely preferred for SCIP flap reconstruction. We report 2 cases with the free SCIP flap for skin and soft tissue reconstruction of the foot under local anesthesia. PATIENT CONCERNS Case 1 was a 34-year-old man sustained a crush injury to the dorsal foot, resulting in a soft tissue defect with bone and tendon exposure. Case 2 was a 41-year-old man with type 2 diabetes was referred to our division for an intractable ankle wound after surgery for a calcaneal bone fracture. DIAGNOSIS The diagnosis was intractable wounds on feet caused by trauma and surgery. Patients were unable to receive general anesthesia because of asthma or elevated liver enzymes. INTERVENTIONS Two patients with tissue defects on their feet were treated with SCIP flaps under local anesthesia. Fifteen milliliter of 0.5% bupivacaine was injected for ankle block. SCIP flaps were harvested after injecting 10 to 15 mL of 1% lidocaine combined with epinephrine around the flap incisions. OUTCOMES No complications related to the use of local anesthesia developed during the operation or postoperatively. Two flaps survived and fully took without complications. LESSONS With proper local anesthesia, successful foot reconstruction with a free SCIP flap was possible. This method can be considered a sufficient option for foot reconstruction for patients unable to receive general anesthesia.
Collapse
Affiliation(s)
- Kenji Hayashida
- Division of Plastic and Reconstructive Surgery, Shimane University Faculty of Medicine
| | - Sho Yamakawa
- Division of Plastic and Reconstructive Surgery, Shimane University Faculty of Medicine
| | - Hiroto Saijo
- Nagasaki University Graduate School of Biomedical Sciences
| | - Masaki Fujioka
- Division of Plastic and Reconstructive Surgery, National Nagasaki Medical Center, Japan
| |
Collapse
|