1
|
Tan X, Ahmed-Kristensen S, Zhu Q, Han T, Zhu L, Chen W, Cao J, Nanayakkara T. Identification of excessive contact pressures under hand orthosis based on finite element analysis. Prosthet Orthot Int 2024:00006479-990000000-00249. [PMID: 38771762 DOI: 10.1097/pxr.0000000000000357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 03/15/2024] [Indexed: 05/23/2024]
Abstract
BACKGROUND Implicit magnitudes and distribution of excessive contact pressures under hand orthoses hinder clinicians from precisely adjusting them to relieve the pressures. To address this, contact pressure under a hand orthosis were analysed using finite element method. METHODS This paper proposed a method to numerically predict the relatively high magnitudes and critical distribution of contact pressures under hand orthosis through finite element analysis, to identify excessive contact pressure locations. The finite element model was established consisting of the hand, orthosis and bones. The hand and bones were assumed to be homogeneous and elastic bodies, and the orthosis was considered as an isotropic and elastic shell. Two predictions were conducted by assigning either low (fat) or high (skin) material stiffness to the hand model to attain the range of pressure magnitudes. An experiment was conducted to measure contact pressures at the predicted pressure locations. RESULTS Identical pressure distributions were obtained from both predictions with relatively high pressure values disseminated at 12 anatomical locations. The highest magnitude was found at the thumb metacarpophalangeal joint with the maximum pressure range from 13 to 78 KPa. The measured values were within the predicted range of pressure magnitudes. Moreover, 6 excessive contact pressure locations were identified. CONCLUSIONS The proposed method was verified by the measurement results. It renders understanding of interface conditions underneath the orthosis to inform clinicians regarding orthosis design and adjustment. It could also guide the development of 3D printed or sensorised orthosis by indicating optimal locations for perforations or pressure sensors.
Collapse
Affiliation(s)
- Xinyang Tan
- School of Design, Shanghai Jiao Tong University, Shanghai, China
| | | | - Qian Zhu
- Department of Rehabilitation Medicine, The Affiliated Xuzhou Rehabilitation Hospital of Xuzhou Medical University, Xuzhou, China
| | - Ting Han
- School of Design, Shanghai Jiao Tong University, Shanghai, China
| | - Lei Zhu
- Dyson School of Design Engineering, Imperial College London, London, UK
| | - Wei Chen
- Department of Rehabilitation Medicine, The Affiliated Xuzhou Rehabilitation Hospital of Xuzhou Medical University, Xuzhou, China
| | - Jiangang Cao
- Department of Assistive Technology, International University of Health and Welfare, Otawara, Japan
| | | |
Collapse
|
2
|
Mena A, Wollstein R, Baus J, Yang J. Finite Element Modeling of the Human Wrist: A Review. J Wrist Surg 2023; 12:478-487. [PMID: 38213568 PMCID: PMC10781520 DOI: 10.1055/s-0043-1768930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 04/13/2023] [Indexed: 01/13/2024]
Abstract
Background Understanding wrist biomechanics is important to appreciate and treat the wrist joint. Numerical methods, specifically, finite element method (FEM), have been used to overcome experimental methods' limitations. Due to the complexity of the wrist and difficulty in modeling, there is heterogeneity and lack of consistent methodology in the published studies, challenging our ability to incorporate information gleaned from the various studies. Questions/Purposes This study summarizes the use of FEM to study the wrist in the last decade. Methods We included studies published from 2012 to 2022 from databases: EBSCO, Research4Life, ScienceDirect, and Scopus. Twenty-two studies were included. Results FEM used to study wrist in general, pathology, and treatment include diverse topics and are difficult to compare directly. Most studies evaluate normal wrist mechanics, all modeling the bones, with fewer studies including cartilage and ligamentous structures in the model. The dynamic effect of the tendons on wrist mechanics is rarely accounted for. Conclusion Due to the complexity of wrist mechanics, the current literature remains incomplete. Considering published strategies and modeling techniques may aid in the development of more comprehensive and improved wrist model fidelity.
Collapse
Affiliation(s)
- Andres Mena
- Human-Centric Design Research Laboratory, Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas
| | - Ronit Wollstein
- Department of Orthopedic Surgery, School of Medicine, New York University, New York, New York
| | - Juan Baus
- Human-Centric Design Research Laboratory, Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas
| | - James Yang
- Human-Centric Design Research Laboratory, Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas
| |
Collapse
|
3
|
Sosa EM, Moure MM. Simulation of low-energy impacts on the human hand for prediction of peak reaction forces and bone fracture. J Biomech 2023; 160:111813. [PMID: 37778278 DOI: 10.1016/j.jbiomech.2023.111813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 09/14/2023] [Accepted: 09/25/2023] [Indexed: 10/03/2023]
Abstract
Hands of workers in extractive and heavy-duty industries are susceptible to suffering injuries of varying severity. Improved safety procedures and new technologies for production and maintenance tasks have contributed to reducing the severity of injuries. However, manual tasks with high-risk factors can still lead to hand injuries. Hand bone fractures and dislocations can be caused by relatively small objects impacting a region of the hand at velocities in the range of 1.3 to 1.6 m per second. This impact can produce significant functional, physical, and psychological consequences in those affected and result in high costs derived from medical care. This study presents the results of a finite element simulation study conducted to reproduce impacts with energies in the range of 7 to 10 Joules of an object on the dorsal region of the hand. Simulation results are compared to previous experimental results obtained from controlled impact tests performed using cadaveric hand specimens. The vertical peak reaction force (PRF) as a function of the impact position was used as a primary outcome for comparisons. Simulation results for all impact positions were within the standard deviation measured experimentally, with differences in the PRF values in the range of -5.3% to 4.9%. Bone stress analyses at the position of impacts showed the locations where the maximum principal stress exceeded the bone strength, as well as the variability in the correspondence between the stress distribution predicted by the FE models and the fracture rate distribution observed experimentally.
Collapse
Affiliation(s)
- Eduardo M Sosa
- Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV 26506, United States.
| | - Marta M Moure
- Aerospace Systems and Transport Research Group, Rey Juan Carlos University, Fuenlabrada, Madrid, Spain.
| |
Collapse
|
4
|
Dong M, Kerkhof F, Deleu G, Vereecke E, Ladd A. Using a finite element model of the thumb to study Trapeziometacarpal joint contact during lateral pinch. Clin Biomech (Bristol, Avon) 2023; 101:105852. [PMID: 36521409 DOI: 10.1016/j.clinbiomech.2022.105852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 11/26/2022] [Accepted: 12/01/2022] [Indexed: 12/10/2022]
Abstract
BACKGROUND Finite element (FE) analysis is widely used in different fields of orthopaedic surgery, however, its application to the trapeziometacarpal joint has been limited due to the small size, complex biconcave-convex joint geometry, and complex musculature. The goal of this study was to improve upon existing models by creating a muscle-driven FE thumb model and use the model to simulate the biomechanical effect of hand therapy exercises and ligament reconstructive surgeries. METHODS Bone and cartilage geometry were based on a CT dataset of a subject performing a static lateral pinch task. A previously validated musculoskeletal model was utilized to extract electromyography (EMG)-driven muscle forces. Five ligaments with biomechanical significance were modeled as springs using literature values and attached according to their anatomical landmarks. FINDINGS The biomechanical consequence of various interventions was proxied as a change in the maximum cartilage stress. The result shows tightening the dorsal ligament complex (dorsal radial ligament, dorsal central ligament, posterior oblique ligament) is the most effective, achieving a stress reduction of 4.8%. Five exercises used in hand therapies were modeled, among which thenar eminence strengthening showed the most prominent stress reduction of 4.0%. Four ligament reconstructive surgeries were modeled, with Eaton-Littler reconstruction showed the most significant stress reduction of 25.0%. INTERPRETATION Among the routinely utilized treatment options for early thumb osteoarthritis, we found that three methods: dorsal ligament imbrication, thenar eminence exercise, and the Eaton-Littler method may confer biomechanical advantages cartilage loading. These advantages align with the clinically observed favorable outcomes.
Collapse
Affiliation(s)
- Meilin Dong
- Stanford University School of Medicine, Stanford, CA, USA.
| | - Faes Kerkhof
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Palo Alto, CA, USA
| | - GertJan Deleu
- Muscles & Movement, Biomedical Sciences Group, University of Leuven Campus Kulak, Kortrijk, Belgium
| | - Evie Vereecke
- Muscles & Movement, Biomedical Sciences Group, University of Leuven Campus Kulak, Kortrijk, Belgium
| | - Amy Ladd
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Palo Alto, CA, USA
| |
Collapse
|
5
|
Spartacus V, Shojaeizadeh M, Raffault V, Shoults J, Van Wieren K, Sparrey CJ. In vivo soft tissue compressive properties of the human hand. PLoS One 2021; 16:e0261008. [PMID: 34898632 PMCID: PMC8668133 DOI: 10.1371/journal.pone.0261008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 11/22/2021] [Indexed: 12/25/2022] Open
Abstract
Background/Purpose Falls onto outstretched hands are the second most common sports injury and one of the leading causes of upper extremity injury. Injury risk and severity depends on forces being transmitted through the palmar surface to the upper extremity. Although the magnitude and distribution of forces depend on the soft tissue response of the palm, the in vivo properties of palmar tissue have not been characterized. The purpose of this study was to characterize the large deformation palmar soft tissue properties. Methods In vivo dynamic indentations were conducted on 15 young adults (21–29 years) to quantify the soft tissue characteristics of over the trapezium. The effects of loading rate, joint position, tissue thickness and sex on soft tissue responses were assessed. Results Energy absorbed by the soft tissue and peak force were affected by loading rate and joint angle. Energy absorbed was 1.7–2.8 times higher and the peak force was 2–2.75 times higher at high rate loading than quasistatic rates. Males had greater energy absorbed than females but not at all wrist positions. Damping characteristics were the highest in the group with the thickest soft tissue while damping characteristics were the lowest in group with the thinnest soft tissues. Conclusion Palmar tissue response changes with joint position, loading rate, sex, and tissue thickness. Accurately capturing these tissue responses is important for developing effective simulations of fall and injury biomechanics and assessing the effectiveness of injury prevention strategies.
Collapse
Affiliation(s)
- Victoria Spartacus
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
- * E-mail:
| | - Maedeh Shojaeizadeh
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
| | - Vincent Raffault
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
| | - James Shoults
- Science Technical Center, Simon Fraser University, Burnaby, BC, Canada
| | - Ken Van Wieren
- Science Technical Center, Simon Fraser University, Burnaby, BC, Canada
| | - Carolyn J. Sparrey
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
- International Collaboration on Repair Discoveries (ICORD), Vancouver, British Columbia, Canada
| |
Collapse
|
6
|
Perevoshchikova N, Moerman KM, Akhbari B, Bindra R, Maharaj JN, Lloyd DG, Gomez Cerezo M, Carr A, Vaquette C, Saxby DJ. Finite element analysis of the performance of additively manufactured scaffolds for scapholunate ligament reconstruction. PLoS One 2021; 16:e0256528. [PMID: 34797871 PMCID: PMC8604338 DOI: 10.1371/journal.pone.0256528] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Accepted: 08/07/2021] [Indexed: 12/11/2022] Open
Abstract
Rupture of the scapholunate interosseous ligament can cause the dissociation of scaphoid and lunate bones, resulting in impaired wrist function. Current treatments (e.g., tendon-based surgical reconstruction, screw-based fixation, fusion, or carpectomy) may restore wrist stability, but do not address regeneration of the ruptured ligament, and may result in wrist functional limitations and osteoarthritis. Recently a novel multiphasic bone-ligament-bone scaffold was proposed, which aims to reconstruct the ruptured ligament, and which can be 3D-printed using medical-grade polycaprolactone. This scaffold is composed of a central ligament-scaffold section and features a bone attachment terminal at either end. Since the ligament-scaffold is the primary load bearing structure during physiological wrist motion, its geometry, mechanical properties, and the surgical placement of the scaffold are critical for performance optimisation. This study presents a patient-specific computational biomechanical evaluation of the effect of scaffold length, and positioning of the bone attachment sites. Through segmentation and image processing of medical image data for natural wrist motion, detailed 3D geometries as well as patient-specific physiological wrist motion could be derived. This data formed the input for detailed finite element analysis, enabling computational of scaffold stress and strain distributions, which are key predictors of scaffold structural integrity. The computational analysis demonstrated that longer scaffolds present reduced peak scaffold stresses and a more homogeneous stress state compared to shorter scaffolds. Furthermore, it was found that scaffolds attached at proximal sites experience lower stresses than those attached at distal sites. However, scaffold length, rather than bone terminal location, most strongly influences peak stress. For each scaffold terminal placement configuration, a basic metric was computed indicative of bone fracture risk. This metric was the minimum distance from the bone surface to the internal scaffold bone terminal. Analysis of this minimum bone thickness data confirmed further optimisation of terminal locations is warranted.
Collapse
Affiliation(s)
- Nataliya Perevoshchikova
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
| | - Kevin M. Moerman
- Biomechanics Research Centre, National University of Ireland Galway, Galway, Ireland
- Center for Extreme Bionics at the Media Lab, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Bardiya Akhbari
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, Rhode Island, United States of America
| | - Randy Bindra
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
- School of Medicine, Griffith University, Gold Coast, QLD, Australia
| | - Jayishni N. Maharaj
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
| | - David G. Lloyd
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
| | | | - Amelia Carr
- School of Dentistry, University of Queensland, Herston, QLD, Australia
| | - Cedryck Vaquette
- School of Dentistry, University of Queensland, Herston, QLD, Australia
| | - David J. Saxby
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, QLD, Australia
| |
Collapse
|
7
|
Tan X, He L, Cao J, Chen W, Nanayakkara T. A Soft Pressure Sensor Skin for Hand and Wrist Orthoses. IEEE Robot Autom Lett 2020. [DOI: 10.1109/lra.2020.2970947] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
8
|
Subject-Specific Finite Element Modelling of the Human Hand Complex: Muscle-Driven Simulations and Experimental Validation. Ann Biomed Eng 2019; 48:1181-1195. [PMID: 31845127 PMCID: PMC7089907 DOI: 10.1007/s10439-019-02439-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2019] [Accepted: 12/10/2019] [Indexed: 11/16/2022]
Abstract
This paper aims to develop and validate a subject-specific framework for modelling the human hand. This was achieved by combining medical image-based finite element modelling, individualized muscle force and kinematic measurements. Firstly, a subject-specific human hand finite element (FE) model was developed. The geometries of the phalanges, carpal bones, wrist bones, ligaments, tendons, subcutaneous tissue and skin were all included. The material properties were derived from in-vivo and in-vitro experiment results available in the literature. The boundary and loading conditions were defined based on the kinematic data and muscle forces of a specific subject captured from the in-vivo grasping tests. The predicted contact pressure and contact area were in good agreement with the in-vivo test results of the same subject, with the relative errors for the contact pressures all being below 20%. Finally, sensitivity analysis was performed to investigate the effects of important modelling parameters on the predictions. The results showed that contact pressure and area were sensitive to the material properties and muscle forces. This FE human hand model can be used to make a detailed and quantitative evaluation into biomechanical and neurophysiological aspects of human hand contact during daily perception and manipulation. The findings can be applied to the design of the bionic hands or neuro-prosthetics in the future.
Collapse
|
9
|
Predict Afferent Tactile Neural Signal for Artificial Nerve Based on Finite Element Human Hand Model. INTELLIGENT ROBOTICS AND APPLICATIONS 2019. [DOI: 10.1007/978-3-030-27526-6_12] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
10
|
Stephens NB, Kivell TL, Pahr DH, Hublin JJ, Skinner MM. Trabecular bone patterning across the human hand. J Hum Evol 2018; 123:1-23. [PMID: 30072187 DOI: 10.1016/j.jhevol.2018.05.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 05/09/2018] [Accepted: 05/10/2018] [Indexed: 02/06/2023]
Abstract
Hand bone morphology is regularly used to link particular hominin species with behaviors relevant to cognitive/technological progress. Debates about the functional significance of differing hominin hand bone morphologies tend to rely on establishing phylogenetic relationships and/or inferring behavior from epigenetic variation arising from mechanical loading and adaptive bone modeling. Most research focuses on variation in cortical bone structure, but additional information about hand function may be provided through the analysis of internal trabecular structure. While primate hand bone trabecular structure is known to vary in ways that are consistent with expected joint loading differences during manipulation and locomotion, no study exists that has documented this variation across the numerous bones of the hand. We quantify the trabecular structure in 22 bones of the human hand (early/extant modern Homo sapiens) and compare structural variation between two groups associated with post-agricultural/industrial (post-Neolithic) and foraging/hunter-gatherer (forager) subsistence strategies. We (1) establish trabecular bone volume fraction (BV/TV), modulus (E), degree of anisotropy (DA), mean trabecular thickness (Tb.Th) and spacing (Tb.Sp); (2) visualize the average distribution of site-specific BV/TV for each bone; and (3) examine if the variation in trabecular structure is consistent with expected joint loading differences among the regions of the hand and between the groups. Results indicate similar distributions of trabecular bone in both groups, with those of the forager sample presenting higher BV/TV, E, and lower DA, suggesting greater and more variable loading during manipulation. We find indications of higher loading along the ulnar side of the forager sample hand, with high site-specific BV/TV distributions among the carpals that are suggestive of high loading while the wrist moves through the 'dart-thrower's' motion. These results support the use of trabecular structure to infer behavior and have direct implications for refining our understanding of human hand evolution and fossil hominin hand use.
Collapse
Affiliation(s)
- Nicholas B Stephens
- Department of Human Evolution, Max Planck Institute for Evolutionary Anthropology, Deutscher Platz 6, 04103 Leipzig, Germany.
| | - Tracy L Kivell
- Skeletal Biology Research Centre, School of Anthropology and Conservation, University of Kent, Canterbury CT2 7NZ, United Kingdom; Department of Human Evolution, Max Planck Institute for Evolutionary Anthropology, Deutscher Platz 6, 04103 Leipzig, Germany
| | - Dieter H Pahr
- Institute for Lightweight Design and Structural Biomechanics, Vienna University of Technology, Getreidemarkt 9, A-1060 Vienna, Austria
| | - Jean-Jacques Hublin
- Department of Human Evolution, Max Planck Institute for Evolutionary Anthropology, Deutscher Platz 6, 04103 Leipzig, Germany
| | - Matthew M Skinner
- Skeletal Biology Research Centre, School of Anthropology and Conservation, University of Kent, Canterbury CT2 7NZ, United Kingdom; Department of Human Evolution, Max Planck Institute for Evolutionary Anthropology, Deutscher Platz 6, 04103 Leipzig, Germany
| |
Collapse
|