1
|
van Eeden D, du Plessis FCP. Electron dose optimisation based on tumour thickness and shape for photon multi-leaf collimated megavoltage electrons. Appl Radiat Isot 2025; 220:111785. [PMID: 40112703 DOI: 10.1016/j.apradiso.2025.111785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2024] [Revised: 02/21/2025] [Accepted: 03/14/2025] [Indexed: 03/22/2025]
Abstract
This study developed an optimisation method that considers tumour thickness for modulated electron radiation treatment (MERT) at a treatment distance of 60 cm. It comprises forming a tumour bed matrix from which a transformed tumour bed matrix is derived. From the discrete tumour bed depth data, electron beam segments were extracted, which were further decomposed into sub-beams. The EGSnrc-based Monte Carlo codes BEAMnrc and DOSXYZnrc were used to model a linear accelerator and to score 3-D dose data for various field sizes (sub-beams) in a water phantom model. The use of different energy and intensity-modulated electron sub-beams to irradiate a parotid lesion was investigated by applying the developed optimisation method. After each sub-beam energy was determined, a least square cost function minimisation was invoked to deliver a minimum dose to the tumour volume and produce a set of weight factors synonymous with beam intensity modulation. This study describes a technique to derive apertures and suitable sub-beam energy to provide a method for planning a robust MERT technique that yields dose-covering results and dose spread within the tumour that aligns with literature studies.
Collapse
Affiliation(s)
- D van Eeden
- Department of Medical Physics, University of the Free State, Bloemfontein, Free State 9301, South Africa.
| | - F C P du Plessis
- Department of Medical Physics, University of the Free State, Bloemfontein, Free State 9301, South Africa
| |
Collapse
|
2
|
Naceur A, Bienvenue C, Romano P, Chilian C, Carrier JF. Extending deterministic transport capabilities for very-high and ultra-high energy electron beams. Sci Rep 2024; 14:2796. [PMID: 38307920 PMCID: PMC11226718 DOI: 10.1038/s41598-023-51143-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 12/31/2023] [Indexed: 02/04/2024] Open
Abstract
Focused Very-High Energy Electron (VHEE, 50-300 MeV) and Ultra-High Energy Electron (UHEE, > 300 MeV) beams can accurately target both large and deeply seated human tumors with high sparing properties, while avoiding the spatial requirements and cost of proton and heavy ion facilities. Advanced testing phases are underway at the CLEAR facilities at CERN (Switzerland), NLCTA at Stanford (USA), and SPARC at INFN (Italy), aiming to accelerate the transition to clinical application. Currently, Monte Carlo (MC) transport is the sole paradigm supporting preclinical trials and imminent clinical deployment. In this paper, we propose an alternative: the first extension of the nuclear-reactor deterministic chain NJOY-DRAGON for VHEE and UHEE applications. We have extended the Boltzmann-Fokker-Planck (BFP) multigroup formalism and validated it using standard radio-oncology benchmarks, complex assemblies with a wide range of atomic numbers, and comprehensive irradiation of the entire periodic table. We report that [Formula: see text] of water voxels exhibit a BFP-MC deviation below [Formula: see text] for electron energies under [Formula: see text]. Additionally, we demonstrate that at least [Formula: see text] of voxels of bone, lung, adipose tissue, muscle, soft tissue, tumor, steel, and aluminum meet the same criterion between [Formula: see text] and [Formula: see text]. For water, the thorax, and the breast intra-operative benchmark, typical average BFP-MC deviations of [Formula: see text] and [Formula: see text] were observed at [Formula: see text] and [Formula: see text], respectively. By irradiating the entire periodic table, we observed similar performance between lithium ([Formula: see text]) and cerium ([Formula: see text]). Deficiencies observed between praseodymium ([Formula: see text]) and einsteinium ([Formula: see text]) have been reported, analyzed, and quantified, offering critical insights for the ongoing development of the Evaluated Nuclear Data File mode in NJOY.
Collapse
Affiliation(s)
- Ahmed Naceur
- École Polytechnique, SLOWPOKE Nuclear Reactor Laboratory, Nuclear Engineering Institute, Montréal, H3T1J4, Canada.
- CRCHUM, Centre hospitalier de l'Université de Montréal, Montréal, H2L4M1, Canada.
| | - Charles Bienvenue
- École Polytechnique, Engineering Physics Department, Biomedical Engineering Institute, Montréal, H3T1J4, Canada
| | - Paul Romano
- Computational Science Division, Argonne National Laboratory, Lemont, IL, 60439, USA
| | - Cornelia Chilian
- École Polytechnique, SLOWPOKE Nuclear Reactor Laboratory, Nuclear Engineering Institute, Montréal, H3T1J4, Canada
| | - Jean-François Carrier
- Department of Physics, Université de Montréal, Montréal, H3T1J4, Canada
- CRCHUM, Centre hospitalier de l'Université de Montréal, Montréal, H2L4M1, Canada
| |
Collapse
|
3
|
Tai YM, Heng VJ, Renaud MA, Serban M, Seuntjens J. Quality assurance for mixed electron-photon beam radiation therapy using treatment log files and MapCHECK. Med Phys 2023; 50:7996-8008. [PMID: 37782074 DOI: 10.1002/mp.16759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 08/16/2023] [Accepted: 09/11/2023] [Indexed: 10/03/2023] Open
Abstract
BACKGROUND Mixed photon-electron beam radiotherapy (MBRT) is a technique that combines the use of both photons and electrons in one single treatment plan to exploit their advantageous and complimentary characteristics. Compared to other photon treatment modalities, it has been shown that the MBRT technique contributes to better target coverage and organ-at-risk (OAR) sparing. However, the use of combined photons and electrons in one delivery makes the technique more complex and a well-established quality assurance (QA) protocol for MBRT is essential. PURPOSE To investigate the feasibility of using MapCHECK and log file-dose reconstruction for MBRT plan verification and to recommend a patient-specific quality assurance (PSQA) protocol for MBRT. METHODS MBRT plans were robustly optimized for five soft-tissue sarcoma (STS) patients. Each plan comprised step-and-shoot deliveries of a six MV photon beam and a combination of five electron beam energies at an SAD of 100 cm. The plans were delivered to the MapCHECK device with collapsed gantry angle and the 2D dose distributions at the detector depth were measured. To simulate the expected dose distribution delivered to the MapCHECK, a MapCHECK computational phantom was modeled in EGSnrc based on vendor-supplied blueprint information. The dose to the detectors in the model was scored using the DOSXYZnrc user code. The agreement between the measured and the simulated dose distribution was evaluated using 2D gamma analysis with a gamma criterion of 3%/2 mm and a low dose threshold of 10%. One of the plans was selected and delivered with a rotating gantry angle for trajectory log file collection. To evaluate the potential interlinac and intralinac differences, the plan was delivered repeatedly on three linacs. From the collected log files, delivery parameters were retrieved to recalculate the 3D dose distributions in the patient's anatomy with DOSXYZnrc. The recalculated mean dose to the clinical target volume (CTV) and OARs from all deliveries were computed and compared with the planned dose in terms of percentage difference. To validate the accuracy of log file-based QA, the log file-recalculated dose was also compared with film measurement. RESULTS The agreement of the total dose distribution between the MapCHECK measurement and simulation showed gamma passing rates of above 97% for all five MBRT plans. In the log file-dose recalculation, the difference between the recalculated and the planned dose to the CTV and OARs was below 1% for all deliveries. No significant inter- or intralinac differences were observed. The log file-dose had a gamma passing rate of 98.6% compared to film measurement. CONCLUSION Both the MapCHECK measurements and log file-dose recalculations showed excellent agreement with the expected dose distribution. This study demonstrates the potential of using MapCHECK and log files as MBRT QA tools.
Collapse
Affiliation(s)
- Yee Man Tai
- Medical Physics Unit, McGill University, Montreal, Canada
| | - Veng Jean Heng
- Department of Physics & Medical Physics Unit, McGill University, Montreal, Canada
| | | | - Monica Serban
- Princess Margaret Cancer Centre & Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Jan Seuntjens
- Princess Margaret Cancer Centre & Department of Radiation Oncology, University of Toronto, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
4
|
Guyer G, Mueller S, Mackeprang PH, Frei D, Volken W, Aebersold DM, Loessl K, Manser P, Fix MK. Delivery time reduction for mixed photon-electron radiotherapy by using photon MLC collimated electron arcs. Phys Med Biol 2023; 68:215009. [PMID: 37816376 DOI: 10.1088/1361-6560/ad021a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 10/10/2023] [Indexed: 10/12/2023]
Abstract
Objective. Electron arcs in mixed-beam radiotherapy (Arc-MBRT) consisting of intensity-modulated electron arcs with dynamic gantry rotation potentially reduce the delivery time compared to mixed-beam radiotherapy containing electron beams with static gantry angle (Static-MBRT). This study aims to develop and investigate a treatment planning process (TPP) for photon multileaf collimator (pMLC) based Arc-MBRT.Approach. An existing TPP for Static-MBRT plans is extended to integrate electron arcs with a dynamic gantry rotation and intensity modulation using a sliding window technique. The TPP consists of a manual setup of electron arcs, and either static photon beams or photon arcs, shortening of the source-to-surface distance for the electron arcs, initial intensity modulation optimization, selection of a user-defined number of electron beam energies based on dose contribution to the target volume and finally, simultaneous photon and electron intensity modulation optimization followed by full Monte Carlo dose calculation. Arc-MBRT plans, Static-MBRT plans, and photon-only plans were created and compared for four breast cases. Dosimetric validation of two Arc-MBRT plans was performed using film measurements.Main results. The generated Arc-MBRT plans are dosimetrically similar to the Static-MBRT plans while outperforming the photon-only plans. The mean heart dose is reduced by 32% on average in the MBRT plans compared to the photon-only plans. The estimated delivery times of the Arc-MBRT plans are similar to the photon-only plans but less than half the time of the Static-MBRT plans. Measured and calculated dose distributions agree with a gamma passing rate of over 98% (3% global, 2 mm) for both delivered Arc-MBRT plans.Significance. A TPP for Arc-MBRT is successfully developed and Arc-MBRT plans showed the potential to improve the dosimetric plan quality similar as Static-MBRT while maintaining short delivery times of photon-only treatments. This further facilitates integration of pMLC-based MBRT into clinical practice.
Collapse
Affiliation(s)
- Gian Guyer
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Silvan Mueller
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Paul-Henry Mackeprang
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Daniel Frei
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Werner Volken
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Daniel M Aebersold
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Kristina Loessl
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Peter Manser
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Michael K Fix
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| |
Collapse
|
5
|
Heng VJ, Serban M, Renaud MA, Freeman C, Seuntjens J. Robust mixed electron-photon radiation therapy planning for soft tissue sarcoma. Med Phys 2023; 50:6502-6513. [PMID: 37681990 DOI: 10.1002/mp.16709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 08/02/2023] [Accepted: 08/20/2023] [Indexed: 09/09/2023] Open
Abstract
BACKGROUND Mixed electron-photon beam radiation therapy (MBRT) is an emerging technique in which external electron and photon beams are simultaneously optimized into a single treatment plan. MBRT exploits the steep dose falloff and high surface dose of electrons while maintaining target conformity by leveraging the sharp penumbra of photons. PURPOSE This study investigates the dosimetric benefits of MBRT for soft tissue sarcoma (STS) patients. MATERIAL AND METHODS A retrospective cohort of 22 STS of the lower extremity treated with conventional photon-based Volumetric Modulated Arc Therapy (VMAT) were replanned with MBRT. Both VMAT and MBRT treatments were planned on the Varian TrueBeam linac using the Millenium multi-leaf collimator. No electron applicator, cutout or additional collimating devices were used for electron beams of MBRT plans. MBRT plans were optimized to use a combination of 6 MV photons and five electron energies (6, 9, 12, 16, 20 MeV) by a robust column generation algorithm. Electron beams in this study were planned at standard 100 cm source-axis distance (SAD). The dose to the clinical target volume (CTV), bone, normal tissue strip and other organs-at-risk (OARs) were compared using a Wilcoxon signed-rank test. RESULTS As part of the original VMAT treatment, tissue-equivalent bolus was required in 10 of the 22 patients. MBRT plans did not require bolus by virtue of the higher electron entrance dose. CTV coverage by the prescription dose was found to be clinically equivalent between plans of either modality:V 50Gy $V_{\text{50Gy}}$ (MBRT) = 97.9 ± 0.2% versusV 50Gy $V_{\text{50Gy}}$ (VMAT) = 98.1 ± 0.6% (p=0.34). Evaluating the absolute paired difference between doses to OARs in MBRT and VMAT plans, we observed lowerV 20Gy $V_{\text{20Gy}}$ to normal tissue in MBRT plans by 14.9 ± 3.2% (p < 10 - 6 $p<10^{-6}$ ). Similarly,V 50Gy $V_{\text{50Gy}}$ to bone was found to be decreased by 8.2 ± 4.0% (p < 10 - 3 $p<10^{-3}$ ) of the bone volume. CONCLUSION For STS with subcutaneous involvement, MBRT offers statistically significant sparing of OARs without sacrificing target coverage when compared to VMAT. MBRT plans are deliverable on conventional linacs without the use of electron applicators, shortened source-to-surface distance (SSD) or bolus. This study shows that MBRT is a logistically feasible technique with clear dosimetric benefits.
Collapse
Affiliation(s)
- Veng Jean Heng
- Department of Physics and Medical Physics Unit, McGill University, Montreal, Canada
| | - Monica Serban
- Princess Margaret Cancer Centre and Department of Radiation Oncology, University of Toronto, Toronto, Canada
- Gerald Bronfman Department of Oncology, Medical Physics Unit, McGill University, Montreal, Canada
| | | | | | - Jan Seuntjens
- Princess Margaret Cancer Centre and Department of Radiation Oncology, University of Toronto, Toronto, Canada
- Gerald Bronfman Department of Oncology, Medical Physics Unit, McGill University, Montreal, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
6
|
Ma P, Tian Y, Li M, Niu C, Song Y, Dai J. Delivery of intensity-modulated electron therapy by mechanical scanning: An algorithm study. Front Oncol 2022; 12:1063577. [PMID: 36505866 PMCID: PMC9730234 DOI: 10.3389/fonc.2022.1063577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 11/07/2022] [Indexed: 11/27/2022] Open
Abstract
Purpose In principle, intensity-modulated electron therapy (IMET) can be delivered through mechanical scanning, with a robotic arm mounting a linac. Materials and methods Here is a scanning algorithm to identify the back-and-forth, top-to-bottom (zigzag) pattern scan sequence. The algorithm includes generating beam positions with a uniform resolution according to the applicator size; adopting discrete energies to achieve the depth of 90% dose by compositing energies; selecting energy by locating the target's distal edge; and employing the energy-by-energy scan strategy for step-and-shoot discrete scanning. After a zigzag scan sequence is obtained, the delivery order of the scan spots is optimized by fast simulated annealing (FSA) to minimize the path length. For algorithm evaluation, scan sequences were generated using the computed tomography data of 10 patients with pancreatic cancer undergoing intraoperative radiotherapy, and the results were compared between the zigzag path and an optimized path. A simple calculation of the treatment delivery time, which comprises the irradiation time, the total robotic arm moving time, the time for energy switch, and the time to stop and restart the beam, was also made. Results In these clinical cases, FSA optimization shortened the path lengths by 12%-43%. Assuming the prescribed dose was 15 Gy, machine dose rate was 15 Gy/s, energy switch time was 2 s, stop and restart beam time was 20 ms, and robotic arm move speed was 50 mm/s, the average delivery time was 124±38 s. The largest reduction in path length yielded an approximately 10% reduction in the delivery time, which can be further reduced by increasing the machine dose rate and the robotic arm speed, decreasing the time for energy switch, and/or developing more efficient algorithms. Conclusion Mechanically scanning IMET is potentially feasible and worthy of further exploration.
Collapse
|
7
|
Heath E, Mueller S, Guyer G, Duetschler A, Elicin O, Aebersold D, Fix MK, Manser P. Implementation and experimental validation of a robust hybrid direct aperture optimization approach for mixed-beam radiotherapy. Med Phys 2021; 48:7299-7312. [PMID: 34585756 PMCID: PMC9292851 DOI: 10.1002/mp.15258] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 08/30/2021] [Accepted: 09/16/2021] [Indexed: 12/24/2022] Open
Abstract
Purpose The objectives of the work presented in this paper were to (1) implement a robust‐optimization method for deliverable mixed‐beam radiotherapy (MBRT) plans within a previously developed MBRT planning framework; (2) perform an experimental validation of the delivery of robust‐optimized MBRT plans; and (3) compare PTV‐based and robust‐optimized MBRT plans in terms of target dose robustness and organs at risk (OAR) sparing for clinical head and neck and brain patient cases. Methods A robust‐optimization method, which accounts for translational setup errors, was implemented within a previously developed treatment planning framework for MBRT. The framework uses a hybrid direct aperture optimization method combining column generation and simulated annealing. A robust plan was developed and then delivered to an anthropomorphic head phantom using the Developer Mode of a TrueBeam linac. Planar dose distributions were measured and compared to the planned dose. Robust‐optimized and PTV‐based plans were developed for three clinical patient cases consisting of two head and neck cases and one brain case. The plans were compared in terms of the robustness to 5 mm shifts of the target volume dose as well as in terms of OAR sparing. Results Using a gamma criterion of 3%/2 mm and a dose threshold of 10%, the agreement between film measurements and dose calculations was better than 97.7% for the total plan and better than 95.5% for the electron component of the plan. For the two head and neck patient cases, the average clinical target volume (CTV) dose homogeneity index (V95%–V107%) over all the considered setup error scenarios was on average 19% lower for the PTV‐based plans and it had a larger standard deviation. The robust‐optimized plans achieved, on average, a 20% reduction in the OAR doses compared to the PTV‐based plans. For the brain patient case, the CTV dose homogeneity index was similar for the two plans, while the OAR doses were 22% lower, on average, for the robust‐optimized plan. No clear trend in terms of electron contributions was found across the three patient cases, although robust‐optimized plans tended toward higher electron beam energies. Conclusions A framework for robust optimization of deliverable MBRT plans has been developed and validated. PTV‐based MBRT were found to not be robust to setup errors, while the dose delivered by the robust‐optimized plans were clinically acceptable for all considered error scenarios and had better OAR sparing. This study shows that the robust optimization is a promising alternative to conventional PTV margins for MBRT.
Collapse
Affiliation(s)
- Emily Heath
- Carleton Laboratory for Radiotherapy Physics, Carleton University, Ottawa, Canada
| | - Silvan Mueller
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Gian Guyer
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Alisha Duetschler
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland.,Department of Physics, ETH Zurich, Zurich, Switzerland.,Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | - Olgun Elicin
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Daniel Aebersold
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Michael K Fix
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Peter Manser
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| |
Collapse
|
8
|
Breitkreutz DY, Skinner L, Lo S, Yu A. Nontoxic electron collimators. J Appl Clin Med Phys 2021; 22:73-81. [PMID: 34480841 PMCID: PMC8504586 DOI: 10.1002/acm2.13398] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 06/16/2021] [Accepted: 07/28/2021] [Indexed: 12/22/2022] Open
Abstract
Purpose The goal of this work was to develop and test nontoxic electron collimation technologies for clinical use. Methods Two novel technologies were investigated: tungsten‐silicone composite and 3D printed electron cutouts. Transmission, dose uniformity, and profiles were measured for the tungsten‐silicone. Surface dose, relative dose output, and field size were measured for the 3D printed cutouts and compared with the standard cerrobend cutouts in current clinical use. Quality assurance tests including mass measurements, Megavoltage (MV) imaging, and drop testing were developed for the 3D printed cutouts as a guide to safe clinical implementation. Results Dose profiles of the flexible tungsten‐silicone skin shields had an 80–20 penumbra values of 2–3 mm compared to 7–8 mm for cerrobend. In MV transmission image measurements of the tungsten‐silicone, 80% of the pixels had a transmission value within 2% of the mean. An ∼90% reduction in electron intensity was measured for 6 MeV and a 6.4 mm thickness of tungsten‐silicone and 12.7 mm thickness for 16 MeV. The maximum difference in 3D printed cutout versus cerrobend output, surface dose, and full width at half‐maximum (FWHM) was 1.7%, 1.2%, and 1.5%, respectively, for the 10 cm × 10 cm cutouts. Conclusions Both flexible tungsten‐silicone and 3D printed cutouts were found to be feasible for clinical use. The flexible tungsten‐silicone was of adequate density, flexibility, and uniformity to serve as skin shields for electron therapy. The 3D printed cutouts were dosimetrically equivalent to standard cerrobend cutouts and were robust enough for handling in the clinical environment.
Collapse
Affiliation(s)
| | - Lawrie Skinner
- Department of Radiation Oncology, Stanford University, Stanford, California, USA
| | - Stephanie Lo
- Department of Radiation Oncology, Stanford University, Stanford, California, USA
| | - Amy Yu
- Department of Radiation Oncology, Stanford University, Stanford, California, USA
| |
Collapse
|
9
|
Heng VJ, Serban M, Seuntjens J, Renaud MA. Ion chamber and film-based quality assurance of mixed electron-photon radiation therapy. Med Phys 2021; 48:5382-5395. [PMID: 34224144 DOI: 10.1002/mp.15081] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 05/27/2021] [Accepted: 06/06/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE In previous work, we demonstrated that mixed electron-photon radiation therapy (MBRT) produces treatment plans with improved normal tissue sparing and similar target coverage, when compared to photon-only plans. The purpose of this work was to validate the MBRT delivery process on a Varian TrueBeam accelerator and laying the groundwork for a patient-specific quality assurance (QA) protocol based on ion chamber point measurements and 2D film measurements. METHODS MC beam models used to calculate the MBRT dose distributions of each modality (photons/electrons) were validated with a single-angle beam MBRT treatment plan delivered on a slab of Solid Water phantom with a film positioned at a depth of 2 cm. The measured film absorbed dose was compared to the calculated dose. To validate clinical deliveries, a polymethyl methacrylate (PMMA) cylinder was machined and holes were made to fit an ionization chamber. A complex MBRT plan involving a photon arc and three electron delivery angles was created with the aim of reproducing a clinically realistic dose distribution in typical soft tissue sarcoma tumours of the extremities. The treatment plan was delivered on the PMMA cylinder. Point measurements were taken with an Exradin A1SL chamber at two nominal depths: 1.4 cm and 2.1 cm. The plan was also delivered on a second identical phantom with an insert at 2 cm depth, where a film was placed. An existing EGSnrc user-code, SPRRZnrc, was modified to calculate the stopping power ratios between any materials in the same voxelized geometry used for dose calculation purposes. This modified code, called SPRXYZnrc, was used to calculate a correction factor, k MBRT , accounting for the differences in electron fluence spectrum at the measurement point compared to that at reference conditions. The uncertainty associated with neglecting potential ionization chamber fluence perturbation correction factors using this approach was estimated. RESULTS The film measurement from the Solid Water phantom treatment plan was in good agreement with the simulated dose distribution, with a gamma pass rate of 96.1% for a 3%/2 mm criteria. For the PMMA phantom delivery, for the same gamma criteria, the pass rate was 97.3%. The ion chamber measurements of the total delivered dose agreed with the MC-simulated dose within 2.1%. The beam quality correction factors amounted to, at most, a 4% correction on the ion chamber measurement. However, individual contribution of low electron energies proved difficult to precisely measure due to their steep dose gradients, with disagreements of up to 28% ± 15% at 2.1 cm depth (6 MeV). Ion chamber measurement procedure of electron beams was achieved in less than 5 min, and the entire validation process including phantom setup was performed in less than 30 min. CONCLUSION The agreement between measured and simulated MBRT doses indicates that the dose distributions obtained from the MBRT treatment planning algorithm are realistically achievable. The SPRXYZnrc MC code allowed for convenient calculations of k MBRT simultaneously with the dose distributions, laying the groundwork for patient-specific QA protocol practical for clinical use. Further investigation is needed to establish the accuracy of our ionization chamber correction factors k MBRT calculations at low electron energies.
Collapse
Affiliation(s)
- Veng Jean Heng
- Department of Physics and Medical Physics Unit, McGill University, Montreal, QC, Canada
| | - Monica Serban
- Department of Medical Physics, McGill University Health Centre, Montreal, QC, Canada
| | - Jan Seuntjens
- Medical Physics Unit, McGill University and Research Institute of the McGill University Health Centre, Montreal, QC, Canada
| | - Marc-André Renaud
- Department of Mathematics and Industrial Engineering, Polytechnique Montréal, Montreal, QC, Canada
| |
Collapse
|
10
|
Fadavi P, Ahmadi HK, Diba AAY, Jafari F, Alamolhoda M. Dosimetric comparison of left sided whole breast irradiation with Tangential wedge beam, electron boosted Tangential wedged beam and asymmetric technique. J Family Med Prim Care 2020; 9:6135-6139. [PMID: 33681053 PMCID: PMC7928138 DOI: 10.4103/jfmpc.jfmpc_1476_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 09/15/2020] [Accepted: 11/03/2020] [Indexed: 11/05/2022] Open
Abstract
Background: Irradiation of the adjacent critical structures is inevitable in breast cancer radiotherapy (RT). Our purpose is to assess the dose distribution across the breast tissue and adjacent organs with our institutional asymmetric technique for left-sided breast cancer compared to the standard tangential wedged beam (TWB) and electron-boosted TWB techniques. Materials and Methods: The three RT planning were created for 30 consecutive patients with a focus on proper coverage of the planning target volume (PTV). The irritated doses into the heart, ipsilateral lung, and left anterior descending artery (LAD) were evaluated. Results: No significant difference was found in the mean values of relative PTV irradiated to 47.5 Gy, PTV dose and the volume of PTV, and critical organs between the treatments. The mean dose (Dmean) irradiated to the heart and LAD was lowest with the electron-boosted TWB. The Dmean to the heart was comparable between the TWB and asymmetric RT techniques, while the Dmean to LAD was significantly reduced with asymmetric technique versus TWB. The heart volume receiving ≥25 Gy and the Dmean to the left lung were significantly decreased with the asymmetric technique compared with TWB. The mean relative lung volume irradiated to ≥20 Gy was comparable between all techniques. The mean central lung distance was also significantly increased from 18.03 ± 4.5 cm with asymmetric RT to 37.47 ± 5.6 cm with TWB and to 27.67 ± 3.8 cm with electron-boosted TWB techniques. Conclusion: The asymmetric technique is useful for patients with breast cancer on the left side, having acceptable PTV coverage and considerably reduced cardiopulmonary doses.
Collapse
Affiliation(s)
- Pedram Fadavi
- Department of Radiation Oncology, Shohadaye 7 Tir Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Helaleh Khoshbakht Ahmadi
- Department of Radiation Oncology, Shohadaye 7 Tir Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Ali Asghar Yousefi Diba
- Department of Radiation Oncology, Shohadaye 7 Tir Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Fatemeh Jafari
- Radiation Oncology Research Center, Cancer Institute, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran.,Department of Radiation Oncology, Cancer Institute, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahboobeh Alamolhoda
- Department of Radiation Oncology, Shohadaye 7 Tir Hospital, Iran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
11
|
One layer at a time: the use of 3D printing in the fabrication of cadmium-free electron field shaping devices. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396920001107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Abstract
Introduction:
Electron blocks are typically composed of a low melting point alloy (LMPA), which is poured into an insert frame containing a manually placed Styrofoam aperture negative used to define the desired field shape. Current implementations of the block fabrication process involve numerous steps which are subjective and prone to user error. Occasionally, bowing of the sides of the insert frame is observed, resulting in premature frame decommissioning. Recent works have investigated the feasibility of utilising 3D printing technology to replace the conventional electron block fabrication workflow; however, these approaches involved long print times, were not compatible with commonly used cadmium-free LMPAs, and did not address the problem of insert frame bowing. In this work, we sought to develop a new 3D printing technique that would remedy these issues.
Materials and Methods:
Electron cutout negatives and alignment jigs were printed using Acrylonitrile Butadiene Styrene, which does not warp at the high temperatures associated with molten cadmium-free alloys. The accuracy of the field shape produced by electron blocks fabricated using the 3D printed negatives was assessed using Gafchromic film and beam profiler measurements. As a proof-of-concept, electron blocks with off-axis apertures, as well as complex multi-aperture blocks to be used for passive electron beam intensity modulation, were also created.
Results:
Film and profiler measurements of field size were in excellent agreement with the values calculated using the Eclipse treatment planning system, showing less than a 1% difference in line profile full-width at half-maximum. The multi-aperture electron blocks produced fields with intensity modulation ≤3.2% of the theoretically predicted value. Use of the 3D printed alignment jig – which has contours designed to match those of the insert frame – was found to reduce the amount of frame bowing by factors of 1.8 and 2.1 in the lateral and superior–inferior directions, respectively.
Conclusions:
The 3D printed ABS negatives generated with our technique maintain their spatial accuracy even at the higher temperatures associated with cadmium-free LMPA. The negatives typically take between 1 and 2 hours to print and have a material cost of approximately $2 per patient.
Collapse
|
12
|
Kaluarachchi MM, Saleh ZH, Schwer ML, Klein EE. Validation of a Monte Carlo model for multi leaf collimator based electron delivery. Med Phys 2020; 47:3586-3599. [PMID: 32324289 DOI: 10.1002/mp.14194] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 03/12/2020] [Accepted: 03/31/2020] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To develop and validate a Monte Carlo model of the Varian TrueBeam to study electron collimation using the existing photon multi-leaf collimators (pMLC), instead of conventional electron applicators and apertures. MATERIALS AND METHODS A complete Monte Carlo model of the Varian TrueBeam was developed using Tool for particle simulation (TOPAS) (version 3.1.p3). Vendor-supplied information was used to model the treatment head components and the source parameters. A phase space plane was setup above the collimating jaws and captured particles were reused until a statistical uncertainty of 1% was achieved in the central axis. Electron energies 6, 9, 12, 16, and 20 MeV with a jaw-defined field of 20 × 20 cm2 at iso-center, pMLC-defined fields of 6.8 × 6.8 cm2 and 11.4 × 11.4 cm2 at 80 cm source-to-surface distance (SSD) and an applicator-defined field of 10 × 10 cm2 at iso-center were evaluated. All the measurements except the applicator-defined fields were measured using an ionization chamber in a water tank using 80 cm SSD. The dose difference, distance-to-agreement and gamma index were used to evaluate the agreement between the Monte Carlo calculations and measurements. Contributions of electron scattering off pMLC leaves and inter-leaf leakage on dose profiles were evaluated and compared with Monte Carlo calculations. Electron transport through a heterogeneous phantom was simulated and the resulting dose distributions were compared with film measurements. The validated Monte Carlo model was used to simulate several clinically motivated cases to demonstrate the benefit of pMLC-based electron delivery compared to applicator-based electron delivery. RESULTS Calculated and measured percentage depth-dose (PDD) curves agree within 2% after normalization. The agreement between normalized percentage depth dose curves were evaluated using one-dimensional gamma analysis with a local tolerance of 2%/1 mm and the %points passing gamma criteria was 100% for all energies. For jaw-defined fields, calculated profiles agree with measurements with pass rates of >97% for 2%/2 mm gamma criteria. Calculated FWHM and penumbra width agree with measurements within 0.4 cm. For fields with tertiary collimation using an pMLC or applicator, the average gamma pass rate of compared profiles was 98% with 2%/2 mm gamma criteria. The profiles measured to evaluate the pMLC leaf scattering agreed with Monte Carlo calculations with an average gamma pass rate of 96.5% with 3%/2 mm gamma criteria. Measured dose profiles below the heterogenous phantom agreed well with calculated profiles and matched within 2.5% for most points. The calculated clinically applicable cases using TOPAS MC and Eclipse TPS for single enface electron beam, electron-photon mixed beam and a matched electron-electron beam exhibited a reasonable agreement in PDDs, profiles and dose volume histograms. CONCLUSION We present a validation of a Monte Carlo model of Varian TrueBeam for pMLC-based electron delivery. Monte Carlo calculations agreed with measurements satisfying gamma criterion of 1%/1 mm for depth dose curves and 2%/1 mm for dose profiles. The simulation of clinically applicable cases demonstrated the clinical utility of pMLC-based electrons and the use of MC simulations for development of advanced radiation therapy techniques.
Collapse
Affiliation(s)
- Maduka M Kaluarachchi
- Department of Radiation Oncology, Rhode Island Hospital/Brown University, Providence, RI, 02905, USA
| | - Ziad H Saleh
- Department of Radiation Oncology, Rhode Island Hospital/Brown University, Providence, RI, 02905, USA
| | - Michelle L Schwer
- Department of Radiation Oncology, Rhode Island Hospital/Brown University, Providence, RI, 02905, USA
| | - Eric E Klein
- Department of Radiation Oncology, Rhode Island Hospital/Brown University, Providence, RI, 02905, USA
| |
Collapse
|
13
|
Ma C, Parsons D, Chen M, Jiang S, Hou Q, Gu X, Lu W. Electron modulated arc therapy (EMAT) using photon MLC for postmastectomy chest wall treatment I: Monte Carlo-based dosimetric characterizations. Phys Med 2019; 67:1-8. [PMID: 31606657 PMCID: PMC6925626 DOI: 10.1016/j.ejmp.2019.10.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 10/02/2019] [Accepted: 10/03/2019] [Indexed: 12/14/2022] Open
Abstract
PURPOSE To study the dosimetric properties of electron arc beams delivered by photon-beam multi-leaf collimators (pMLC) in electron modulated arc therapy (EMAT) for postmastectomy chest wall treatments. METHODS Using the Monte Carlo method, we simulated a 2100EX Varian linear accelerator and verified the beam models in a water tank. Dosimetric characterizations were performed on cylindrical water phantoms of elliptical bases with various field sizes, arc ranges and source-to-surface distances (SSDs) for 6, 9 and 12 MeV beam energy. RESULTS The arc beam has a higher bremsstrahlung dose than the static beam at the isocenter due to crossfire, but choosing a field size greater than 5 cm effectively reduces the bremsstrahlung dose. The depths of the 90% maximum dose located at 1.7, 2.8 and 4.1 cm for 6, 9 and 12 MeV, respectively, are similar to those of the static beams and independent of the field size and arc range. CONCLUSION Based on the study, we recommend using the 5 cm field width for electron arc beams considering both bremsstrahlung dose at the isocenter and the arc profile penumbra. To ensure sufficient PTV edge coverage, we recommend a field length extension of at least 4 cm from PTV's edge for all beam energies and an arc extension of around 7°, 5°, and 5° for beam energies 6, 9, and 12 MeV, respectively. These dosimetric characterizations are the basis of pMLC-delivered EMAT treatment planning for postmastectomy chest wall patients.
Collapse
Affiliation(s)
- Chaoqiong Ma
- Key Lab for Radiation Physics and Technology of Education Ministry of China, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, Sichuan 610064, China; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA
| | - David Parsons
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA
| | - Mingli Chen
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA
| | - Steve Jiang
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA
| | - Qing Hou
- Key Lab for Radiation Physics and Technology of Education Ministry of China, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, Sichuan 610064, China
| | - Xuejun Gu
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA
| | - Weiguo Lu
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
| |
Collapse
|
14
|
Skinner L, Fahimian BP, Yu AS. Tungsten filled 3D printed field shaping devices for electron beam radiation therapy. PLoS One 2019; 14:e0217757. [PMID: 31216296 PMCID: PMC6584017 DOI: 10.1371/journal.pone.0217757] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Accepted: 05/19/2019] [Indexed: 11/18/2022] Open
Abstract
Purpose Electron radiotherapy is a labor-intensive treatment option that is complicated by the need for field shaping blocks. These blocks are typically made from casting Cerrobend alloys containing lead and cadmium. This is a highly toxic process with limited precision. This work aims to provide streamlined and more precise electron radiotherapy by 3D using printing techniques. Methods The 3D printed electron cutout consists of plastic shells filled with 2 mm diameter tungsten ball bearings. Five clinical Cerrobend defined field were compared to the planned fields by measuring the light field edge when mounted in the electron applicator on a linear accelerator. The dose transmitted through the 3D printed and Cerrobend cutouts was measured using an IC profiler ion chamber array with 6 MeV and 16 MeV beams. Dose profiles from the treatment planning system were also compared to the measured dose profiles. Centering and full width half maximum (FWHM) metrics were taken directly from the profiler software. Results The transmission of a 16MeV beam through a 12 mm thick layer of tungsten ball bearings agreed within 1% of a 15 mm thick Cerrobend block (measured with an ion chamber array). The radiation fields shaped by ball bearing filled 3D printed cutout were centered within 0.4 mm of the planned outline, whereas the Cerrobend cutout fields had shift errors of 1–3 mm, and shape errors of 0.5–2 mm. The average shift of Cerrobend cutouts was 2.3 mm compared to the planned fields (n = 5). Beam penumbra of the 3D printed cutouts was found to be equivalent to the 15 mm thick Cerrobend cutout. The beam profiles agreed within 1.2% across the whole 30 cm profile widths. Conclusions This study demonstrates that with a proper quality assurance procedure, 3D-printed cutouts can provide more accurate electron radiotherapy with reduced toxicity compared to traditional Cerrobend methods.
Collapse
Affiliation(s)
- Lawrie Skinner
- Department of Radiation Oncology, Stanford University, Palo Alto, CA, United States of America
| | - Benjamin P. Fahimian
- Department of Radiation Oncology, Stanford University, Palo Alto, CA, United States of America
| | - Amy S. Yu
- Department of Radiation Oncology, Stanford University, Palo Alto, CA, United States of America
- * E-mail:
| |
Collapse
|
15
|
Ryu D, Kim JI, Lee S, Ye SJ, Park JM. Remote afterloading patient-specific brachytherapy with liquid radioisotope for irradiation of extensive scalp lesions: A Monte Carlo study. Med Phys 2019; 46:3227-3234. [PMID: 31049969 DOI: 10.1002/mp.13561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2018] [Revised: 03/15/2019] [Accepted: 04/25/2019] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The aim of this study is to propose a remote afterloading patient-specific brachytherapy technique for total scalp irradiation by utilizing liquid radioisotope as well as a three-dimensional (3D) printer and to find an optimal radioisotope for the suggested technique. METHODS We designed a brachytherapy device composed of liquid radioisotope tank, tube, patient-specific applicator, and a thin flexible pouch. The liquid radioisotope tank, tube, and the flexible pouch are interconnected one another to constitute a closed loop system. The pouch is located inside the solid patient-specific applicator; therefore, when the liquid radioisotope is injected into the pouch, the pouch is inflated and fills the space inside the applicator. The 3D-printed patient-specific applicator keeps the uniform thickness of the liquid radioisotope conforming patient's contour. To investigate an optimum condition for the suggested system, we performed Monte Carlo simulation with the GEANT4 simulation toolkit. To find the optimal radioisotope, percent depth doses (PDDs) of P-32, Sr-89, Y-90, and I-125 solutions were acquired in a rectangular parallelepiped phantom. For the selected radiation source, PDDs as well as dose rates in spherical phantoms with radii of 7.7 cm (infant head size) and 9.1 cm (adult head size) were acquired. RESULTS To deliver prescription doses at 4-mm depth regions (scalp region), 1-mm-thick Y-90 and 5-mm-thick I-125 in liquid form were found to be feasible for the suggested technique. For both spherical phantoms with radii of 7.7 and 9.1 cm, when delivering 2 Gy at the 4-mm depth region with the 1-mm-thick Y-90 and 5-mm-thick I-125 sources, 53.3 and 3.8 Gy were delivered at the surface regions, respectively (delivery time = 111.1 and 3.5 min with 1 GBq/ml solutions). The PDDs of Y-90 and I-125 became less than 1% at depths greater than 8 and 50 mm, respectively. CONCLUSIONS The remote afterloading patient-patient specific brachytherapy with I-125 or Y-90 in liquid form seems feasible for total scalp irradiation.
Collapse
Affiliation(s)
- Dongmin Ryu
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul, 16229, Republic of Korea
| | - Jung-In Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, 03080, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Sangmin Lee
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul, 16229, Republic of Korea
| | - Sung-Joon Ye
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul, 16229, Republic of Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, 03080, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Robotics Research Laboratory for Extreme Environments, Advanced Institutes of Convergence Technology, Suwon, 16229, Republic of Korea
| |
Collapse
|
16
|
Michiels S, Mangelschots B, Roover RD, Devroye C, Depuydt T. Production of patient-specific electron beam aperture cut-outs using a low-cost, multi-purpose 3D printer. J Appl Clin Med Phys 2018; 19:756-760. [PMID: 30047204 PMCID: PMC6123127 DOI: 10.1002/acm2.12421] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 05/31/2018] [Accepted: 06/28/2018] [Indexed: 12/04/2022] Open
Abstract
Electron beam collimators for non‐standard field sizes and shapes are typically fabricated using Styrofoam molds to cast the aperture cut‐out. These molds are often produced using a dedicated foam cutter, which may be expensive and only serves a single purpose. An increasing number of radiotherapy departments, however, has a 3D printer on‐site, to create a wide range of custom‐made treatment auxiliaries, such as bolus and dosimetry phantoms. The 3D printer can also be used to produce patient‐specific aperture cut‐outs, as elaborated in this note. Open‐source programming language was used to automatically generate the mold's shape in a generic digital file format readable by 3D printer software. The geometric mold model has the patient's identification number integrated and is to be mounted on a uniquely fitting, reusable positioning device, which can be 3D printed as well. This assembly likewise fits uniquely onto the applicator tray, ensuring correct and error‐free alignment of the mold during casting of the aperture. For dosimetric verification, two aperture cut‐outs were cast, one using a conventionally cut Styrofoam mold and one using a 3D printed mold. Using these cut‐outs, the clinical plan was delivered onto a phantom, for which the transversal dose distributions were measured at 2 cm depth using radiochromic film and compared using gamma‐index analysis. An agreement score of 99.9% between the measured 2D dose distributions was found in the (10%–80%) dose region, using 1% (local) dose‐difference and 1.0 mm distance‐to‐agreement acceptance criteria. The workflow using 3D printing has been clinically implemented and is in routine use at the author's institute for all patient‐specific electron beam aperture cut‐outs. It allows for a standardized, cost‐effective, and operator‐friendly workflow without the need for dedicated equipment. In addition, it offers possibilities to increase safety and quality of the process including patient identification and methods for accurate mold alignment.
Collapse
Affiliation(s)
- Steven Michiels
- Laboratory of Experimental Radiotherapy, Department of Oncology, KU Leuven - University of Leuven, Leuven, Belgium
| | - Bram Mangelschots
- Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium
| | - Robin De Roover
- Laboratory of Experimental Radiotherapy, Department of Oncology, KU Leuven - University of Leuven, Leuven, Belgium
| | - Cédric Devroye
- Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium
| | - Tom Depuydt
- Laboratory of Experimental Radiotherapy, Department of Oncology, KU Leuven - University of Leuven, Leuven, Belgium.,Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
17
|
Joosten A, Müller S, Henzen D, Volken W, Frei D, Aebersold DM, Manser P, Fix MK. A dosimetric evaluation of different levels of energy and intensity modulation for inversely planned multi-field MERT. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aabe40] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
18
|
Hogstrom KR, Carver RL, Chambers EL, Erhart K. Introduction to passive electron intensity modulation. J Appl Clin Med Phys 2017; 18:10-19. [PMID: 28875590 PMCID: PMC5689915 DOI: 10.1002/acm2.12163] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2017] [Revised: 06/19/2017] [Accepted: 06/28/2017] [Indexed: 11/23/2022] Open
Abstract
This work introduces a new technology for electron intensity modulation, which uses small area island blocks within the collimating aperture and small area island apertures in the collimating insert. Due to multiple Coulomb scattering, electrons contribute dose under island blocks and lateral to island apertures. By selecting appropriate lateral positions and diameters of a set of island blocks and island apertures, for example, a hexagonal grid with variable diameter circular island blocks, intensity modulated beams can be produced for appropriate air gaps between the intensity modulator (position of collimating insert) and the patient. Such a passive radiotherapy intensity modulator for electrons (PRIME) is analogous to using physical attenuators (metal compensators) for intensity modulated x‐ray therapy (IMXT). For hexagonal spacing, the relationship between block (aperture) separation (r) and diameter (d) and the local intensity reduction factor (IRF) is discussed. The PRIME principle is illustrated using pencil beam calculations for select beam geometries in water with half beams modulated by 70%–95% and for one head and neck field of a patient treated with bolus electron conformal therapy. Proof of principle is further illustrated by showing agreement between measurement and calculation for a prototype PRIME. Potential utilization of PRIME for bolus electron conformal therapy, segmented‐field electron conformal therapy, modulated electron radiation therapy, and variable surface geometries is discussed. Further research and development of technology for the various applications is discussed. In summary, this paper introduces a practical, new technology for electron intensity modulation in the clinic, demonstrates proof of principle, discusses potential clinical applications, and suggests areas of further research and development.
Collapse
Affiliation(s)
- Kenneth R Hogstrom
- Mary Bird Perkins Cancer Center, Baton Rouge, LA, USA.,Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA
| | - Robert L Carver
- Mary Bird Perkins Cancer Center, Baton Rouge, LA, USA.,Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA
| | - Erin L Chambers
- Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA
| | | |
Collapse
|
19
|
Renaud M, Serban M, Seuntjens J. On mixed electron–photon radiation therapy optimization using the column generation approach. Med Phys 2017; 44:4287-4298. [DOI: 10.1002/mp.12338] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Revised: 05/01/2017] [Accepted: 05/03/2017] [Indexed: 01/02/2023] Open
Affiliation(s)
- Marc‐André Renaud
- Department of Physics & Medical Physics Unit McGill University Montreal Canada
| | - Monica Serban
- Medical Physics Unit McGill University Health Centre Montreal Canada
| | - Jan Seuntjens
- Medical Physics Unit McGill University and Research Institute of the McGill University Health Centre Montreal Canada
| |
Collapse
|
20
|
Eldib A, Jin L, Martin J, Fan J, Li J, Chibani O, Veltchev I, Price R, Galloway T, Ma CMC. Investigating the dosimetric benefits of modulated electron radiation therapy (MERT) for partial scalp patients. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa70ab] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
21
|
Park JI, Ha SW, Kim JI, Lee H, Lee J, Kim IH, Ye SJ. Design and evaluation of electron beam energy degraders for breast boost irradiation. Radiat Oncol 2016; 11:112. [PMID: 27580698 PMCID: PMC5007734 DOI: 10.1186/s13014-016-0686-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Accepted: 08/19/2016] [Indexed: 11/25/2022] Open
Abstract
Background For breast cancer patients who require electron boost energies between 6 and 9 MeV, an energy degraders (ED) in the 9 MeV beamline was specially designed and manufactured to increase the skin dose of 6 MeV and to reduce the penetration depth of 9 MeV beams. Methods We used Monte Carlo (MC) techniques as a guide in the design of ED for use with linear accelerators. In order to satisfy percent depth dose (PDD) characteristics and dose profile uniformity in water, the shape and thickness of Lucite® ED in the 9 MeV beamline was iteratively optimized and then manufactured. The ED geometry consists of a truncated cone attached on top of a plane plate, with total central thickness of 1.0 cm. The ED was placed on the lower most scraper of the electron applicator. The PDDs, profiles, and output factors were measured in water to validate the MC-based design. Results Skin doses with the EDs increased by 8–9 %, compared to those of the 9 MeV beam. The outputs with the EDs were 0.882 and 0.972 for 10 × 10 and 15 × 15 cm2 cones, respectively, as compared to that of a conventional 9 MeV beam for a 10 × 10 cm2 cone. The X-ray contamination remained less than 1.5 %. In-vivo measurements were also performed for three breast boost patients and showed close agreement with expected values. Conclusions The optimally designed ED in the 9 MeV beamline provides breast conserving patients with a new energy option of 7 MeV for boost of the shallow tumor bed. It would be an alternative to bolus and thus eliminate inconvenience and concern about the daily variation of bolus setup.
Collapse
Affiliation(s)
- Jong In Park
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Seoul National University Graduate School of Convergence Science and Technology, Seoul, 151-742, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.,Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul, Korea
| | - Sung Whan Ha
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.,Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
| | - Jung-In Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.,Advanced Institutes of Convergence Technology, Seoul National University, Suwon, Korea
| | - Hyunseok Lee
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Seoul National University Graduate School of Convergence Science and Technology, Seoul, 151-742, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
| | - Jaegi Lee
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Seoul National University Graduate School of Convergence Science and Technology, Seoul, 151-742, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
| | - Il Han Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.,Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul, Korea
| | - Sung-Joon Ye
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Seoul National University Graduate School of Convergence Science and Technology, Seoul, 151-742, Korea. .,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea. .,Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea. .,Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul, Korea. .,Advanced Institutes of Convergence Technology, Seoul National University, Suwon, Korea.
| |
Collapse
|
22
|
Choi WK, Chun JC, Ju SG, Min BJ, Park SY, Nam HR, Hong CS, Kim M, Koo BY, Lim DH. Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy. ACTA ACUST UNITED AC 2016. [DOI: 10.14316/pmp.2016.27.2.64] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Woo Keun Choi
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Medical Physics, Kyonggi University, Suwon, Korea
| | - Jun Chul Chun
- Department of Medical Physics, Kyonggi University, Suwon, Korea
| | - Sang Gyu Ju
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Byung Jun Min
- Department of Radiation Oncology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Su Yeon Park
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hee Rim Nam
- Department of Radiation Oncology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Chae-Seon Hong
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - MinKyu Kim
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Bum Yong Koo
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Do Hoon Lim
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
23
|
Rodrigues A, Sawkey D, Yin FF, Wu Q. A Monte Carlo simulation framework for electron beam dose calculations using Varian phase space files for TrueBeam Linacs. Med Phys 2015; 42:2389-403. [DOI: 10.1118/1.4916896] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
|
24
|
Renaud MA, Roberge D, Seuntjens J. Latent uncertainties of the precalculated track Monte Carlo method. Med Phys 2015; 42:479-90. [PMID: 25563287 DOI: 10.1118/1.4903502] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. METHODS Particle tracks were pregenerated for electrons and protons using EGSnrc and geant4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (cuda) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a "ground truth" benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of Dmax. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. RESULTS Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤ 1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. CONCLUSIONS The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.
Collapse
Affiliation(s)
- Marc-André Renaud
- Medical Physics Unit, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - David Roberge
- Département de radio-oncologie, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec H2L 4M1, Canada
| | - Jan Seuntjens
- Medical Physics Unit, McGill University, Montreal, Quebec H3G 1A4, Canada
| |
Collapse
|
25
|
Su S, Moran K, Robar JL. Design and production of 3D printed bolus for electron radiation therapy. J Appl Clin Med Phys 2014; 15:4831. [PMID: 25207410 PMCID: PMC5875499 DOI: 10.1120/jacmp.v15i4.4831] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 04/16/2014] [Accepted: 04/13/2014] [Indexed: 12/22/2022] Open
Abstract
This is a proof‐of‐concept study demonstrating the capacity for modulated electron radiation therapy (MERT) dose distributions using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in‐house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity, and homogeneity within the planning target volume (PTV). The algorithm takes advantage of a commercial electron Monte Carlo dose calculation and uses the calculated result as input. Distances along ray lines from the distal side of 90% isodose line to distal surface of the PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using the coefficient of equivalent thickness method. Several regional modulation operators are applied to improve the dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms, and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity are improved compared to that with uniform bolus. For geometric phantoms with air or bone inhomogeneities, the dose homogeneity is markedly improved. The actual printed boluses conform well to the surface of complex anthropomorphic phantoms. The correspondence of the dose distribution between the calculated synthetic bolus and the actual manufactured bolus is shown. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low‐cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of the prescription isodose surface and in sparing immediately adjacent normal tissues. PACS number: 81.40.Wx
Collapse
|
26
|
Connell T, Alexander A, Papaconstadopoulos P, Serban M, Devic S, Seuntjens J. Delivery validation of an automated modulated electron radiotherapy plan. Med Phys 2014; 41:061715. [DOI: 10.1118/1.4876297] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
27
|
Ostheimer C, Janich M, Hübsch P, Gerlach R, Vordermark D. The treatment of extensive scalp lesions using coplanar and non-coplanar photon IMRT: a single institution experience. Radiat Oncol 2014; 9:82. [PMID: 24656070 PMCID: PMC3997930 DOI: 10.1186/1748-717x-9-82] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2014] [Accepted: 03/16/2014] [Indexed: 11/10/2022] Open
Abstract
Background This clinical study compared four different cases of extensive scalp malignancies treated by intensity-modulated radiation therapy. The merits of coplanar and non-coplanar Step-and-shoot total scalp irradiation techniques were evaluated against the background of the literature. Methods Four patients (angiosarcoma, n=2, cutaneous B-cell non-Hodgkin lymphoma, B-NHL, n=1, mycosis fungoides, n=1) treated between 2008 and 2012 at our institution were retrospectively analyzed. For every patient with executed coplanar plan, a non-coplanar plan and vice versa has been calculated additionally for direct comparison. Three patients underwent limited surgery before radiotherapy. Individual adapted bolus material was used for every patient (helmet). Total scalp dose was 30 Gy (B-NHL, mycosis fungoides) and 50 Gy (angiosarcoma) with fractional doses of 2.0-2.5 Gy (without sequential local boost in three patients). Conformity and homogeneity indexes and dose volume histograms were used for treatment plan comparison. Results Dose hot spots were higher in coplanar plans (110-128% Dmax). Non-coplanar plans showed a more homogeneous dose distribution (HI = .12 - .17) and superior PTV coverage (88 - 96%). Target dose coverage was 81-117% in non-coplanar and 30-128% in coplanar plans. Coplanar plans yielded a stronger dose gradient across the target (.7-1.6 Gy/mm) compared to non-coplanar plans (.8-1.3 Gy/mm). The most conformal plan was a non-coplanar plan (CI = .7). Mean and maximum brain doses were comparable and showed an almost linear decrease between min. and max. dose. The optic chiasm and brain stem was spared most with non-coplanar plans, mean doses to the lenses ranged between 4 and 8 Gy and were higher in non-coplanar plans as were doses to the optic nerves. Radiotherapy tolerance was acceptable and acute side effects included erythema, scalp pain, alopecia and radiodermatitis which all spontaneously resolved. Two patients accomplished partial response, two patients showed complete response after radiotherapy. Three patients had locally controlled tumors without recurrence until their deaths or at last follow up, one patient had local progression shortly after radiotherapy. Conclusions Photon-IMRT is an effective and feasible approach to treat extensive scalp malignancies. Non-coplanar beams could increase dose homogeneity and PTV coverage and might reduce doses particularly to the optic chiasm.
Collapse
Affiliation(s)
- Christian Ostheimer
- Department of Radiation Oncology, Martin Luther University Halle-Wittenberg Medical School, Dryanderstrasse 4, Halle 06110, Germany.
| | | | | | | | | |
Collapse
|
28
|
Eldib A, Jin L, Li J, Charlie Ma CM. Investigation of the clinical potential of scattering foil free electron beams. Phys Med Biol 2014; 59:819-36. [DOI: 10.1088/0031-9155/59/4/819] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
29
|
Jin L, Eldib A, Li J, Emam I, Fan J, Wang L, Ma CM. Measurement and Monte Carlo simulation for energy- and intensity-modulated electron radiotherapy delivered by a computer-controlled electron multileaf collimator. J Appl Clin Med Phys 2014; 15:4506. [PMID: 24423848 PMCID: PMC5711222 DOI: 10.1120/jacmp.v15i1.4506] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2013] [Revised: 09/25/2013] [Accepted: 09/15/2013] [Indexed: 11/23/2022] Open
Abstract
The dosimetric advantage of modulated electron radiotherapy (MERT) has been explored by many investigators and is considered to be an advanced radiation therapy technique in the utilization of electrons. A computer‐controlled electron multileaf collimator (MLC) prototype, newly designed to be added onto a Varian linac to deliver MERT, was investigated both experimentally and by Monte Carlo simulations. Four different electron energies, 6, 9, 12, and 15 MeV, were employed for this investigation. To ensure that this device was capable of delivering the electron beams properly, measurements were performed to examine the electron MLC (eMLC) leaf leakage and to determine the appropriate jaw positioning for an eMLC‐shaped field in order to eliminate a secondary radiation peak that could otherwise appear outside of an intended radiation field in the case of inappropriate jaw positioning due to insufficient radiation blockage from the jaws. Phase space data were obtained by Monte Carlo (MC) simulation and recorded at the plane just above the jaws for each of the energies (6, 9, 12, and 15 MeV). As an input source, phase space data were used in MC dose calculations for various sizes of the eMLC shaped field (10×10 cm2, 3.4×3.4 cm2, and 2×2 cm2) with respect to a water phantom at source‐to‐surface distance (SSD)=94cm, while the jaws, eMLC leaves, and some accessories associated with the eMLC assembly as well were modeled as modifiers in the calculations. The calculated results were then compared with measurements from a water scanning system. The results showed that jaw settings with 5 mm margins beyond the field shaped by the eMLC were appropriate to eliminate the secondary radiation peak while not widening the beam penumbra; the eMLC leaf leakage measurements ranged from 0.3% to 1.8% for different energies based on in‐phantom measurements, which should be quite acceptable for MERT. Comparisons between MC dose calculations and measurements showed agreement within 1%/1mm based on percentage depth doses (PDDs) and off‐axis dose profiles for a range of field sizes for each of the electron energies. Our current work has demonstrated that the eMLC and other relevant components in the linac were correctly modeled and simulated via our in‐house MC codes, and the eMLC is capable of accurately delivering electron beams for various eMLC‐shaped field sizes with appropriate jaw settings. In the next stage, patient‐specific verification with a full MERT plan should be performed. PACS number: 87.55.ne
Collapse
|
30
|
Rodrigues A, Yin FF, Wu Q. Dynamic electron arc radiotherapy (DEAR): a feasibility study. Phys Med Biol 2013; 59:327-45. [DOI: 10.1088/0031-9155/59/2/327] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
31
|
Eldib A, Jin L, Li J, Ma CMC. Feasibility of replacing patient specific cutouts with a computer-controlled electron multileaf collimator. Phys Med Biol 2013; 58:5653-72. [PMID: 23892910 DOI: 10.1088/0031-9155/58/16/5653] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A motorized electron multileaf collimator (eMLC) was developed as an add-on device to the Varian linac for delivery of advanced electron beam therapy. It has previously been shown that electron beams collimated by an eMLC have very similar penumbra to those collimated by applicators and cutouts. Thus, manufacturing patient specific cutouts would no longer be necessary, resulting in the reduction of time taken in the cutout fabrication process. Moreover, cutout construction involves handling of toxic materials and exposure to toxic fumes that are usually generated during the process, while the eMLC will be a pollution-free device. However, undulation of the isodose lines is expected due to the finite size of the eMLC. Hence, the provided planned target volume (PTV) shape will not exactly follow the beam's-eye-view of the PTV, but instead will make a stepped approximation to the PTV shape. This may be a problem when the field edge is close to a critical structure. Therefore, in this study the capability of the eMLC to achieve the same clinical outcome as an applicator/cutout combination was investigated based on real patient computed tomographies (CTs). An in-house Monte Carlo based treatment planning system was used for dose calculation using ten patient CTs. For each patient, two plans were generated; one with electron beams collimated using the applicator/cutout combination; and the other plan with beams collimated by the eMLC. Treatment plan quality was compared for each patient based on dose distribution and dose-volume histogram. In order to determine the optimal position of the leaves, the impact of the different leaf positioning strategies was investigated. All plans with both eMLC and cutouts were generated such that 100% of the target volume receives at least 90% of the prescribed dose. Then the percentage difference in dose between both delivery techniques was calculated for all the cases. The difference in the dose received by 10% of the volume of the target was showing a mean percentage difference of 1.57%± 1.65, while the difference in the dose received by 99% of the volume was showing a mean percentage difference of 1.08%± 0.78. The mean percentage volume of Lung receiving a percentage dose equal to or greater than 20% of the prescribed dose was found to be 8.55%± 7.3 and 8.67%± 7 for the eMLC and applicator/cutout combination delivery methods respectively. Results have shown that target coverage and critical structure sparing can be effectively achieved by electron beams collimated with the eMLC. Positioning the eMLC leaves in such a way to avoids shielding any part of the projected treatment volume is most conservative and would be the recommended method to define the actual leaf position for the eMLC defined field. More optimal leaf positions can be achieved in shaping the same treatment field through the interplay of different leaf positioning strategies. We concluded that the eMLC represents an effective time saving and pollution-free device that can completely replace patient specific cutouts.
Collapse
Affiliation(s)
- Ahmed Eldib
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA.
| | | | | | | |
Collapse
|
32
|
Chatelain C, Vetterli D, Henzen D, Favre P, Morf D, Scheib S, Fix MK, Manser P. Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy. Med Phys 2013; 40:061710. [DOI: 10.1118/1.4805113] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
|
33
|
Papaconstadopoulos P, Seuntjens J. A source model for modulated electron radiation therapy using dynamic jaw movements. Med Phys 2013; 40:051707. [PMID: 23635255 DOI: 10.1118/1.4800492] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE The development of fast and accurate source models (SMs) might be of crucial importance for the future clinical implementation of modulated electron radiation therapy (MERT). In this study, a SM is presented for reconstructing phase-space information of modulated electron beams using a few-leaf electron collimator (FLEC) and the photon jaws. METHODS During a FLEC-based delivery, two collimation devices (jaws and FLEC) modulate the electron beam characteristics dynamically. The SM separates the beam into a primary and a scattered component. The primary component is derived by a fast Monte Carlo (MC) transport calculation in air using the EGSnrc/BEAMnrc code. The scattered beam is modeled analytically. The accelerator was decomposed into its individual leaf components and the scattered beam was characterized at various levels of the accelerator. Scattered particles are assigned an energy and position by sampling pre-calculated probability distributions. The direction is estimated by geometrical arguments. Particles were assumed to emerge from tunable virtual sources on the side of each collimator leaf. A leaf-hit algorithm was developed to dynamically reject particles that are incident on any collimating leaf. Electron transport in air between the two collimation levels was calculated based on a MC-modified version of the Fermi-Eyges scattering theory. Correlations between direction and position were observed and taken into account at the final collimation level. RESULTS To validate the model, reconstructed phase-space data were compared with the full accelerator MC phase-space data. The model accurately reproduced the beam characteristics and preserved important correlations. Depth and profile dose distributions in water were derived for square, rectangular, and off-axis field sizes and for a range of clinical energies. Discrepancies in the dose distributions and dose output were within 3% in all cases. CONCLUSIONS Fast and accurate SMs open the possibility for fast treatment planning in MERT, based on an inverse optimization MC treatment planning scheme.
Collapse
Affiliation(s)
- Pavlos Papaconstadopoulos
- Medical Physics Unit, McGill University, Montreal General Hospital, 1650 Cedar Avenue, Montreal, Quebec H3G 1A4, Canada.
| | | |
Collapse
|
34
|
Wei W, Liu Y, Yang X, Tian S, Liu C, Zhang Y, Xu Z, Hu B, Tian Z, Sun K. Fractionation of 50kGy electron beam irradiation: effects on biomechanics of human flexor digitorum superficialis tendons treated with ascorbate. J Biomech 2012; 46:658-61. [PMID: 23261247 DOI: 10.1016/j.jbiomech.2012.11.049] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Revised: 11/23/2012] [Accepted: 11/25/2012] [Indexed: 11/28/2022]
Abstract
The electron beam (Ebeam) irradiation has begun to be considered as an efficient alternative to gamma irradiation in the sterilization of allografts in the reconstruction of anterior cruciate ligament. The purpose of this study was to evaluate the biomechanical properties of human tendons after exposure to electron beam and free radical scavenger ascorbate. Forty human flexor digitorum superficialis tendons were prepared from five fresh cadavers and divided randomly into four groups: A, fresh (0kGy); B, 50kGy Ebeam irradiation; C, fractionated 50kGy Ebeam irradiation; D, fractionated 50kGy Ebeam on ascorbate-treated tendons. The fractionation of 50kGy was achieved by repeated irradiation of 2.5kGy for 20 repetitions. Biomechanical properties were analyzed during load-to-failure testing. The fresh tendons were found to be significant different in ultimate load, ultimate elongation relative to tendons in group B. Statistical differences were found between group B and C in ultimate load. No differences were detected between group A and C in all the parameters. Compare tendons in group C and D, significant differences were found in ultimate load and ultimate stress. It is recommended that fractionated 50kGy electron beam irradiation and free radical scavenger ascorbate should be applied in the sterilization of allografts tendons.
Collapse
Affiliation(s)
- Wei Wei
- Department of Orthopedics, the Affiliated Hospital of Medical College, Qingdao University, Qingdao 266003, China.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
35
|
Alexander A, Soisson E, Renaud MA, Seuntjens J. Direct aperture optimization for FLEC-based MERT and its application in mixed beam radiotherapy. Med Phys 2012; 39:4820-31. [DOI: 10.1118/1.4736423] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
36
|
Lundh O, Rechatin C, Faure J, Ben-Ismaïl A, Lim J, De Wagter C, De Neve W, Malka V. Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator. Med Phys 2012; 39:3501-8. [DOI: 10.1118/1.4719962] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
37
|
Rosca F. A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware. Med Phys 2012; 39:2964-71. [PMID: 22755681 DOI: 10.1118/1.4709606] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Affiliation(s)
- Florin Rosca
- Department of Radiation Oncology, Massachusetts General Hospital, Danvers, MA 01923, USA.
| |
Collapse
|
38
|
Connell T, Alexander A, Evans M, Seuntjens J. An experimental feasibility study on the use of scattering foil free beams for modulated electron radiotherapy. Phys Med Biol 2012; 57:3259-72. [PMID: 22572043 DOI: 10.1088/0031-9155/57/11/3259] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The potential benefit of using scattering foil free beams for delivery of modulated electron radiotherapy is investigated in this work. Removal of the scattering foil from the beamline showed a measured bremsstrahlung tail dose reduction just beyond R(p) by a factor of 12.2, 6.9, 7.4, 7.4 and 8.3 for 6, 9, 12, 16 and 20 MeV beams respectively for 2 × 2 cm(2) fields defined on-axis when compared to the clinical beamline. Monte Carlo simulations were matched to measured data through careful tuning of source parameters and the modification of certain accelerator components beyond the manufacturer's specifications. An accelerator model based on the clinical beamline and one with the scattering foil removed were imported into a Monte Carlo-based treatment planning system (McGill Monte Carlo Treatment Planning). A treatment planning study was conducted on a test phantom consisting of a PTV and two distal organs at risk (OAR) by comparing a plan using the clinical beamline to a plan using a scattering foil free beamline. A DVH comparison revealed that for quasi-identical target coverage, the volume of each OAR receiving a given dose was reduced, thus reducing the dose deposited in healthy tissue.
Collapse
Affiliation(s)
- T Connell
- Medical Physics Unit, McGill University, Montreal General Hospital, Montreal, Quebec, Canada.
| | | | | | | |
Collapse
|
39
|
Palma BA, Sánchez AU, Salguero FJ, Arráns R, Sánchez CM, Zurita AW, Hermida MIR, Leal A. Combined modulated electron and photon beams planned by a Monte-Carlo-based optimization procedure for accelerated partial breast irradiation. Phys Med Biol 2012; 57:1191-202. [DOI: 10.1088/0031-9155/57/5/1191] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
40
|
Blasi O, Fontenot JD, Fields RS, Gibbons JP, Hogstrom KR. Preliminary comparison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity. Radiat Oncol 2011; 6:178. [PMID: 22204477 PMCID: PMC3274488 DOI: 10.1186/1748-717x-6-178] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2011] [Accepted: 12/28/2011] [Indexed: 11/18/2022] Open
Abstract
Background and Purpose To investigate combining unmodulated electron beams with intensity-modulated radiation therapy to improve dose distributions for superficial head and neck cancers, and to compare mixed beam plans with helical tomotherapy. Materials and methods Mixed beam and helical tomotherapy dose plans were developed for two patients with parotid gland tumors and two patients with nasal cavity tumors. Mixed beam plans consisted of various weightings of a enface electron beam and IMRT, which was optimized after calculation of the electron dose to compensate for heterogeneity in the electron dose distribution within the target volume. Results Helical tomotherapy plans showed dose conformity and homogeneity in the target volume that was equal to or better than the mixed beam plans. Electron-only plans tended to show the lowest doses to normal tissues, but with markedly worse dose conformity and homogeneity than in the other plans. However, adding a 20% IMRT dose fraction (i.e., IMRT:electron weighting = 1:4) to the electron plan restored target conformity and homogeneity to values comparable to helical tomotherapy plans, while maintaining lower normal tissue dose. Conclusions Mixed beam treatments offer some dosimetric advantages over IMRT or helical tomotherapy for target depths that do not exceed the useful range of the electron beam. Adding a small IMRT component (e.g., IMRT:electron weighting = 1:4) to electron beam plans markedly improved target dose homogeneity and conformity for the cases examined in this study.
Collapse
Affiliation(s)
- Olivier Blasi
- Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, Baton Rouge, LA, USA
| | | | | | | | | |
Collapse
|
41
|
Eley JG, Hogstrom KR, Matthews KL, Parker BC, Price MJ. Potential of discrete Gaussian edge feathering method for improving abutment dosimetry in eMLC-delivered segmented-field electron conformal therapy. Med Phys 2011; 38:6610-22. [PMID: 22149843 DOI: 10.1118/1.3660289] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The purpose of this work was to investigate the potential of discrete Gaussian edge feathering of the higher energy electron fields for improving abutment dosimetry in the planning volume when using an electron multileaf collimator (eMLC) to deliver segmented-field electron conformal therapy (ECT). METHODS A discrete (five-step) Gaussian edge spread function was used to match dose penumbras of differing beam energies (6-20 MeV) at a specified depth in a water phantom. Software was developed to define the leaf eMLC positions of an eMLC that most closely fit each electron field shape. The effect of 1D edge feathering of the higher energy field on dose homogeneity was computed and measured for segmented-field ECT treatment plans for three 2D PTVs in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of the x-axis (parallel to leaf motion) and remained constant along the y-axis (perpendicular to leaf motion). Additionally, the effect of 2D edge feathering was computed and measured for one radially symmetric, 3D PTV in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of both axes. For the 3D PTV, the feathering scheme was evaluated for 0.1-1.0-cm leaf widths. Dose calculations were performed using the pencil beam dose algorithm in the Pinnacle(3) treatment planning system. Dose verification measurements were made using a prototype eMLC (1-cm leaf width). RESULTS 1D discrete Gaussian edge feathering reduced the standard deviation of dose in the 2D PTVs by 34, 34, and 39%. In the 3D PTV, the broad leaf width (1 cm) of the eMLC hindered the 2D application of the feathering solution to the 3D PTV, and the standard deviation of dose increased by 10%. However, 2D discrete Gaussian edge feathering with simulated eMLC leaf widths of 0.1-0.5 cm reduced the standard deviation of dose in the 3D PTV by 33-28%, respectively. CONCLUSIONS A five-step discrete Gaussian edge spread function applied in 2D improves the abutment dosimetry but requires an eMLC leaf resolution better than 1 cm.
Collapse
Affiliation(s)
- John G Eley
- Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, Louisiana 70803-4001, USA.
| | | | | | | | | |
Collapse
|
42
|
Fractionation of high-dose electron beam irradiation of BPTB grafts provides significantly improved viscoelastic and structural properties compared to standard gamma irradiation. Knee Surg Sports Traumatol Arthrosc 2011; 19:1955-61. [PMID: 21541710 DOI: 10.1007/s00167-011-1518-9] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2010] [Accepted: 04/12/2011] [Indexed: 12/14/2022]
Abstract
PURPOSE Irradiation >30 kGy is required to achieve sterility against bacterial and viral pathogens in ACL allograft sterilization. However, doses >20 kGy substantially reduce the structural properties of soft-tissue grafts. Fractionation of irradiation doses is a standard procedure in oncology to reduce tissue damage but has not been applied in tissue graft sterilization. METHODS Forty-four human 10-mm wide bone-patellar-tendon-bone grafts were randomized into four groups of sterilization with (1) 34 kGy of ebeam (2) 34 kGy gamma (3) 34 kGy fractionated ebeam, and (4) non sterilized controls. Graft´s biomechanical properties were evaluated at time zero. Biomechanical properties were analyzed during cyclic and load-to-failure testing. RESULTS Fractionation of ebeam irradiation resulted in significantly higher failure loads (1,327 ± 305) than with one-time ebeam irradiation (1,024 ± 204; P = 0.008). Compared to gamma irradiation, significantly lower strain (2.9 ± 1.5 vs. 4.6 ± 2.0; P = 0.008) and smaller cyclic elongation response (0.3 ± 0.2 vs. 0.6 ± 0.4; P = 0.05), as well as higher failure loads (1,327 ± 305 vs. 827 ± 209; P = 0.001), were found. Compared to non-irradiated BPTB grafts, no significant differences were found for any of the biomechanical parameters. Non-irradiated controls had significantly lower cyclic elongation response and higher failure loads than ebeam and gamma irradiation. CONCLUSIONS In this study, it was found that fractionation of high-dose electron beam irradiation facilitated a significant improvement of viscoelastic and structural properties of BPTB grafts compared to ebeam and gamma irradiation alone, while maintaining levels of non-irradiated controls. Therefore, this technique might pose an important alternative to common methods for sterilization of soft-tissue allografts.
Collapse
|
43
|
Ge Y, Faddegon BA. Study of intensity-modulated photon–electron radiation therapy using digital phantoms. Phys Med Biol 2011; 56:6693-708. [DOI: 10.1088/0031-9155/56/20/012] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
44
|
Mosalaei H, Karnas S, Shah S, Van Doodewaard S, Foster T, Chen J. The use of intensity-modulated radiation therapy photon beams for improving the dose uniformity of electron beams shaped with MLC. Med Dosim 2011; 37:76-83. [PMID: 21925867 DOI: 10.1016/j.meddos.2011.01.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2009] [Revised: 01/05/2011] [Accepted: 01/13/2011] [Indexed: 11/30/2022]
Abstract
Electrons are ideal for treating shallow tumors and sparing adjacent normal tissue. Conventionally, electron beams are collimated by cut-outs that are time-consuming to make and difficult to adapt to tumor shape throughout the course of treatment. We propose that electron cut-outs can be replaced using photon multileaf collimator (MLC). Two major problems of this approach are that the scattering of electrons causes penumbra widening because of a large air gap, and available commercial treatment planning systems (TPSs) do not support MLC-collimated electron beams. In this study, these difficulties were overcome by (1) modeling electron beams collimated by photon MLC for a commercial TPS, and (2) developing a technique to reduce electron beam penumbra by adding low-energy intensity-modulated radiation therapy (IMRT) photons (4 MV). We used blocks to simulate MLC shielding in the TPS. Inverse planning was used to optimize boost photon beams. This technique was applied to a parotid and a central nervous system (CNS) clinical case. Combined photon and electron plans were compared with conventional plans and verified using ion chamber, film, and a 2D diode array. Our studies showed that the beam penumbra for mixed beams with 90 cm source to surface distance (SSD) is comparable with electron applicators and cut-outs at 100 cm SSD. Our mixed-beam technique yielded more uniform dose to the planning target volume and lower doses to various organs at risk for both parotid and CNS clinical cases. The plans were verified with measurements, with more than 95% points passing the gamma criteria of 5% in dose difference and 5 mm for distance to agreement. In conclusion, the study has demonstrated the feasibility and potential advantage of using photon MLC to collimate electron beams with boost photon IMRT fields.
Collapse
Affiliation(s)
- Homeira Mosalaei
- London Regional Cancer Program, London Health Science Centre, Ontario, Canada.
| | | | | | | | | | | |
Collapse
|
45
|
Alexander A, Soisson E, Hijal T, Sarfehnia A, Seuntjens J. Comparison of modulated electron radiotherapy to conventional electron boost irradiation and volumetric modulated photon arc therapy for treatment of tumour bed boost in breast cancer. Radiother Oncol 2011; 100:253-8. [PMID: 21741103 DOI: 10.1016/j.radonc.2011.05.081] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2011] [Revised: 05/20/2011] [Accepted: 05/23/2011] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND PURPOSE To compare few leaf electron collimator (FLEC)-based modulated electron radiotherapy (MERT) to conventional direct electron (DE) and volumetric modulated photon arc therapy (VMAT) for the treatment of tumour bed boost in breast cancer. MATERIALS AND METHODS Fourteen patients with breast cancer treated by lumpectomy and requiring post-operative whole breast radiotherapy with tumour bed boost were planned retrospectively using conventional DE, VMAT and FLEC-based MERT. The planning goal was to deliver 10Gy to at least 95% of the tumour bed volume. Dosimetry parameters for all techniques were compared. RESULTS Dose evaluation volume (DEV) coverage and homogeneity were best for MERT (D(98)=9.77Gy, D(2)=11.03Gy) followed by VMAT (D(98)=9.56Gy, D(2)=11.07Gy) and DE (D(98)=9.81Gy, D(2)=11.52Gy). Relative to the DE plans, the MERT plans predicted a reduction of 35% in mean breast dose (p<0.05), 54% in mean lung dose (p<0.05) and 46% in mean body dose (p<0.05). Relative to the VMAT plans, the MERT plans predicted a reduction of 24%, 36% and 39% in mean breast dose, heart dose and body dose, respectively (p<0.05). CONCLUSIONS MERT plans were a considerable improvement in dosimetry over DE boost plans. There was a dosimetric advantage in using MERT over VMAT for increased DEV conformity and low-dose sparing of healthy tissue including the integral dose; however, the cost is often an increase in the ipsilateral lung high-dose volume.
Collapse
Affiliation(s)
- Andrew Alexander
- Medical Physics Unit, McGill University, Montreal, Quebec, Canada.
| | | | | | | | | |
Collapse
|
46
|
Mihaljevic J, Soukup M, Dohm O, Alber M. Monte Carlo simulation of small electron fields collimated by the integrated photon MLC. Phys Med Biol 2011; 56:829-43. [DOI: 10.1088/0031-9155/56/3/018] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
47
|
Zeidan OA, Chauhan BD, Estabrook WW, Willoughby TR, Manon RR, Meeks SL. Image-guided bolus electron conformal therapy - a case study. J Appl Clin Med Phys 2010; 12:3311. [PMID: 21330977 PMCID: PMC5718591 DOI: 10.1120/jacmp.v12i1.3311] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2010] [Revised: 07/02/2010] [Accepted: 08/27/2010] [Indexed: 11/23/2022] Open
Abstract
We report on our initial experience with daily image guidance for the treatment of a patient with a basal cell carcinoma of the nasal dorsum using bolus electron conformal therapy. We describe our approach to daily alignment using treatment machine‐integrated megavoltage (MV) planar imaging in conjunction with cone beam CT (CBCT) volumetric imaging to ensure the best possible setup reproducibility. Based on MV imaging, beam aperture misalignment with the intended treatment region was as large as 0.5 cm in the coronal plane. Four of the five fractions analyzed show induced shifts when compared to digitally reconstructed radiographs (DRR), in the range of 0.2−0.5 cm. Daily inspection of CBCT images show that the bolus device can have significant tilt in any given direction by as much as 13° with respect to beam axis. In addition, we show that CBCT images reveal air gaps between bolus and skin that vary from day to day, and can potentially degrade surface dose coverage. Retrospective dose calculation on CBCT image sets shows that when daily shifts based on MV imaging are not corrected, geometrical miss of the planning target volume (PTV) can cause an underdosing as large as 14% based on DVH analysis of the dose to the 90% of the PTV volume. PACS number: 87.55.kh
Collapse
Affiliation(s)
- Omar A Zeidan
- Department of Radiation Oncology, M.D. Anderson Cancer Center Orlando, Orlando, FL 32806, USA.
| | | | | | | | | | | |
Collapse
|
48
|
Surucu M, Klein EE, Mamalui-Hunter M, Mansur DB, Low DA. Planning tools for modulated electron radiotherapy. Med Phys 2010; 37:2215-24. [DOI: 10.1118/1.3395573] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
49
|
Eldib AAR, ElGohary MI, Fan J, Jin L, Li J, Ma C, Elsherbini NA. Dosimetric characteristics of an electron multileaf collimator for modulated electron radiation therapy. J Appl Clin Med Phys 2010; 11:2913. [PMID: 20592689 PMCID: PMC5719949 DOI: 10.1120/jacmp.v11i2.2913] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2008] [Revised: 11/11/2009] [Accepted: 12/31/2009] [Indexed: 11/23/2022] Open
Abstract
Modulated electron radiation therapy (MERT) has been proven as an effective way to deliver conformal dose distributions to shallow tumors while sparing distal critical structures and surrounding normal tissues. It had been shown that a dedicated electron multileaf collimator (eMLC) is necessary to reach the full potential of MERT. In this study, a manually-driven eMLC for MERT was investigated. Percentage depth dose (PDD) curves and profiles at different depths in a water tank were measured using ionization chamber and were also simulated using the Monte Carlo method. Comparisons have been performed between PDD curves and profiles collimated using the eMLC and conventional electron applicators with similar size of opening. Monte Carlo simulations were performed for all electron energies available (6, 9, 12, 15, 18 and 20 MeV) on a Varian 21EX accelerator. Monte Carlo simulation results were compared with measurements which showed good agreement (< 2%/1mm). The simulated dose distributions resulting from multiple static electron fields collimated by the eMLC agreed well with measurements. Further studies were carried out to investigate the properties of abutting electron beams using the eMLC, as it is an essential issue that needs to be addressed for optimizing the MERT outcome. A series of empirical formulas for abutting beams of different energies have been developed for obtaining the optimum gap sizes, which can highly improve the target dose uniformity.
Collapse
|
50
|
Salguero FJ, Arráns R, Palma BA, Leal A. Intensity- and energy-modulated electron radiotherapy by means of an xMLC for head and neck shallow tumors. Phys Med Biol 2010; 55:1413-27. [PMID: 20150682 DOI: 10.1088/0031-9155/55/5/010] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The purpose of this paper is to assess the feasibility of delivering intensity- and energy-modulated electron radiation treatment (MERT) by a photon multileaf collimator (xMLC) and to evaluate the improvements obtained in shallow head and neck (HN) tumors. Four HN patient cases covering different clinical situations were planned by MERT, which used an in-house treatment planning system that utilized Monte Carlo dose calculation. The cases included one oronasal, two parotid and one middle ear tumors. The resulting dose-volume histograms were compared with those obtained from conventional photon and electron treatment techniques in our clinic, which included IMRT, electron beam and mixed beams, most of them using fixed-thickness bolus. Experimental verification was performed with plane-parallel ionization chambers for absolute dose verification, and a PTW ionization chamber array and radiochromic film for relative dosimetry. A MC-based treatment planning system for target with compromised volumes in depth and laterally has been validated. A quality assurance protocol for individual MERT plans was launched. Relative MC dose distributions showed a high agreement with film measurements and absolute ion chamber dose measurements performed at a reference point agreed with MC calculations within 2% in all cases. Clinically acceptable PTV coverage and organ-at-risk sparing were achieved by using the proposed MERT approach. MERT treatment plans, based on delivery of intensity-modulated electron beam using the xMLC, for superficial head and neck tumors, demonstrated comparable or improved PTV dose homogeneity with significantly lower dose to normal tissues. The clinical implementation of this technique will be able to offer a viable alternative for the treatment of shallow head and neck tumors.
Collapse
Affiliation(s)
- Francisco Javier Salguero
- Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, and Hospital Universitario Virgen Macarena, Sevilla, Spain
| | | | | | | |
Collapse
|