1
|
Friot-Giroux L, Peyrin F, Maxim V. Iterative tomographic reconstruction with TV prior for low-dose CBCT dental imaging. Phys Med Biol 2022; 67. [PMID: 36162406 DOI: 10.1088/1361-6560/ac950c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 09/26/2022] [Indexed: 12/24/2022]
Abstract
Objective.Cone-beam computed tomography is becoming more and more popular in applications such as 3D dental imaging. Iterative methods compared to the standard Feldkamp algorithm have shown improvements in image quality of reconstruction of low-dose acquired data despite their long computing time. An interesting aspect of iterative methods is their ability to include prior information such as sparsity-constraint. While a large panel of optimization algorithms along with their adaptation to tomographic problems are available, they are mainly studied on 2D parallel or fan-beam data. The issues raised by 3D CBCT and moreover by truncated projections are still poorly understood.Approach.We compare different carefully designed optimization schemes in the context of realistic 3D dental imaging. Besides some known algorithms, SIRT-TV and MLEM, we investigate the primal-dual hybrid gradient (PDHG) approach and a newly proposed MLEM-TV optimizer. The last one is alternating EM steps and TV-denoising, combination not yet investigated for CBCT. Experiments are performed on both simulated data from a 3D jaw phantom and data acquired with a dental clinical scanner.Main results.With some adaptations to the specificities of CBCT operators, PDHG and MLEM-TV algorithms provide the best reconstruction quality. These results were obtained by comparing the full-dose image with a low-dose image and an ultra low-dose image.Significance.The convergence speed of the original iterative methods is hampered by the conical geometry and significantly reduced compared to parallel geometries. We promote the pre-conditioned version of PDHG and we propose a pre-conditioned version of the MLEM-TV algorithm. To the best of our knowledge, this is the first time PDHG and convergent MLEM-TV algorithms are evaluated on experimental dental CBCT data, where constraints such as projection truncation and presence of metal have to be jointly overcome.
Collapse
Affiliation(s)
- Louise Friot-Giroux
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69620, LYON, France
| | - Françoise Peyrin
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69620, LYON, France
| | - Voichita Maxim
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69620, LYON, France
| |
Collapse
|
2
|
Dellmann MFW, Jerg KI, Stratemeier J, Heiman R, Hesser JW, Aschenbrenner KP, Blessing M. Noise-robust breathing-phase estimation on marker-free, ultra low dose X-ray projections for real-time tumor localization via surrogate structures. Z Med Phys 2021; 31:355-364. [PMID: 34088565 DOI: 10.1016/j.zemedi.2021.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 11/11/2020] [Accepted: 04/08/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE This paper presents a novel strategy for feature-based breathing-phase estimation on ultra low-dose X-ray projections for tumor motion control in radiation therapy. METHODS Coarse-scaled Curvelet coefficients are identified as motion sensitive but noise-robust features for this purpose. For feature-based breathing-phase estimation, an ensemble strategy with two classifiers is used. This consensus-based estimation substantially increases tracking reliability by rejection of false positives. The algorithm is evaluated on both synthetic and measured phantom data: Monte Carlo simulated ultra low dose projections for a C-arm X-ray and on the basis of 4D-chest-CTs of eight patients on one hand side and real measurements based on a motion phantom. RESULTS To achieve an accuracy of breathing-phase estimation of more than 95% a fluence between 20 and 400 photons per pixel (open field) is required depending on the patient. Furthermore, the algorithm is evaluated on real ultra low dose projections from an XVI R5.0 system (Elekta AB, Stockholm, Sweden) using an additional lead filter to reduce fluence. The classifiers-consensus-based-gating method estimated the correct position of the test projections in all test cases at a fluence of ∼180 photons per pixel and 92% at a fluence of ∼40 photons per pixel. The deposited dose to patient per image is in the range of nGy. CONCLUSIONS A novel method is presented for estimation of breathing-phases for real-time tumor localization at ultra low dose both on a simulation and a phantom basis. Its accuracy is comparable to state of the art X-ray based algorithms while the released dose to patients is reduced by two to three orders of magnitude compared to conventional template-based approaches. This allows for continuous motion control during irradiation without the need of external markers.
Collapse
Affiliation(s)
- Max F W Dellmann
- Department of Data Analysis and Modeling in Medicine, Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty of Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
| | - Katharina I Jerg
- Department of Data Analysis and Modeling in Medicine, Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty of Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Johanna Stratemeier
- Department of Data Analysis and Modeling in Medicine, Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty of Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Ron Heiman
- Department of Data Analysis and Modeling in Medicine, Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty of Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Jürgen W Hesser
- Department of Data Analysis and Modeling in Medicine, Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty of Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany; Interdisciplinary Center for Scientific Computing (IWR), Heidelberg University, Im Neuenheimer Feld 205, 69120 Heidelberg, Germany; Central Institute for Computer Engineering (ZITI), Heidelberg University, Im Neuenheimer Feld 368, 69120 Heidelberg, Germany
| | - Katharina P Aschenbrenner
- Department of Data Analysis and Modeling in Medicine, Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty of Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany; Interdisciplinary Center for Scientific Computing (IWR), Heidelberg University, Im Neuenheimer Feld 205, 69120 Heidelberg, Germany
| | - Manuel Blessing
- Department of Data Analysis and Modeling in Medicine, Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty of Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| |
Collapse
|
3
|
Lee C, Song H, Baek J. 3D MTF estimation using sphere phantoms for cone‐beam computed tomography systems. Med Phys 2020; 47:2838-2851. [DOI: 10.1002/mp.14147] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 02/11/2020] [Accepted: 03/11/2020] [Indexed: 12/26/2022] Open
Affiliation(s)
- Changwoo Lee
- Center for Medical Convergence Metrology Korea Research Institute of Standards and Science (KRISS) 267 Gajeong‐ro, Yuseong‐gu Daejeon34113 South Korea
| | - Hoon‐dong Song
- School of Integrated Technology and Yonsei Institute of Convergence Technology Yonsei University 85, Songdo‐gwahak‐ro, Yeonsu‐gu Incheon21983 South Korea
| | - Jongduk Baek
- School of Integrated Technology and Yonsei Institute of Convergence Technology Yonsei University 85, Songdo‐gwahak‐ro, Yeonsu‐gu Incheon21983 South Korea
| |
Collapse
|
4
|
A review of GPU-based medical image reconstruction. Phys Med 2017; 42:76-92. [PMID: 29173924 DOI: 10.1016/j.ejmp.2017.07.024] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Revised: 07/06/2017] [Accepted: 07/30/2017] [Indexed: 11/20/2022] Open
Abstract
Tomographic image reconstruction is a computationally demanding task, even more so when advanced models are used to describe a more complete and accurate picture of the image formation process. Such advanced modeling and reconstruction algorithms can lead to better images, often with less dose, but at the price of long calculation times that are hardly compatible with clinical workflows. Fortunately, reconstruction tasks can often be executed advantageously on Graphics Processing Units (GPUs), which are exploited as massively parallel computational engines. This review paper focuses on recent developments made in GPU-based medical image reconstruction, from a CT, PET, SPECT, MRI and US perspective. Strategies and approaches to get the most out of GPUs in image reconstruction are presented as well as innovative applications arising from an increased computing capacity. The future of GPU-based image reconstruction is also envisioned, based on current trends in high-performance computing.
Collapse
|
5
|
Feasibility of using single photon counting X-ray for lung tumor position estimation based on 4D-CT. Z Med Phys 2017; 27:243-254. [PMID: 28595774 DOI: 10.1016/j.zemedi.2017.05.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Revised: 01/04/2017] [Accepted: 05/12/2017] [Indexed: 11/24/2022]
Abstract
PURPOSE In stereotactic body radiation therapy of lung tumors, reliable position estimation of the tumor is necessary in order to minimize normal tissue complication rate. While kV X-ray imaging is frequently used, continuous application during radiotherapy sessions is often not possible due to concerns about the additional dose. Thus, ultra low-dose (ULD) kV X-ray imaging based on a single photon counting detector is suggested. This paper addresses the lower limit of photons to locate the tumor reliably with an accuracy in the range of state-of-the-art methods, i.e. a few millimeters. METHOD 18 patient cases with four dimensional CT (4D-CT), which serves as a-priori information, are included in the study. ULD cone beam projections are simulated from the 4D-CTs including Poisson noise. The projections from the breathing phases which correspond to different tumor positions are compared to the ULD projection by means of Poisson log-likelihood (PML) and correlation coefficient (CC), and template matching under these metrics. RESULTS The results indicate that in full thorax imaging five photons per pixel suffice for a standard deviation in tumor positions of less than half a breathing phase. Around 50 photons per pixel are needed to achieve this accuracy with the field of view restricted to the tumor region. Compared to CC, PML tends to perform better for low photon counts and shifts in patient setup. Template matching only improves the position estimation in high photon counts. The quality of the reconstruction is independent of the projection angle. CONCLUSIONS The accuracy of the proposed ULD single photon counting system is in the range of a few millimeters and therefore comparable to state-of-the-art tumor tracking methods. At the same time, a reduction in photons per pixel by three to four orders of magnitude relative to commercial systems with flatpanel detectors can be achieved. This enables continuous kV image-based position estimation during all fractions since the additional dose to the patient is negligible.
Collapse
|
6
|
Xu L, Chen R, Yang Y, Deng B, Du G, Xie H, Xiao T. Monochromatic-beam-based dynamic X-ray microtomography based on OSEM-TV algorithm. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2017; 25:1007-1017. [PMID: 28777770 DOI: 10.3233/xst-17279] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Monochromatic-beam-based dynamic X-ray computed microtomography (CT) was developed to observe evolution of microstructure inside samples. However, the low flux density results in low efficiency in data collection. To increase efficiency, reducing the number of projections should be a practical solution. However, it has disadvantages of low image reconstruction quality using the traditional filtered back projection (FBP) algorithm. In this study, an iterative reconstruction method using an ordered subset expectation maximization-total variation (OSEM-TV) algorithm was employed to address and solve this problem. The simulated results demonstrated that normalized mean square error of the image slices reconstructed by the OSEM-TV algorithm was about 1/4 of that by FBP. Experimental results also demonstrated that the density resolution of OSEM-TV was high enough to resolve different materials with the number of projections less than 100. As a result, with the introduction of OSEM-TV, the monochromatic-beam-based dynamic X-ray microtomography is potentially practicable for the quantitative and non-destructive analysis to the evolution of microstructure with acceptable efficiency in data collection and reconstructed image quality.
Collapse
Affiliation(s)
- Liang Xu
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Rongchang Chen
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
| | - Yiming Yang
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Biao Deng
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
| | - Guohao Du
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
| | - Honglan Xie
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
| | - Tiqiao Xiao
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
- University of Chinese Academy of Sciences, Beijing, China
| |
Collapse
|
7
|
Vengrinovich VL, Zolotarev SA, Mirzavand MA. Iterative conic beam tomography based on Bayesian approach to radiation therapy. PATTERN RECOGNITION AND IMAGE ANALYSIS 2016. [DOI: 10.1134/s1054661816040192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
8
|
Shi Q, Sun N, Sun T, Wang J, Tan S. Structure-adaptive CBCT reconstruction using weighted total variation and Hessian penalties. BIOMEDICAL OPTICS EXPRESS 2016; 7:3299-3322. [PMID: 27699100 PMCID: PMC5030012 DOI: 10.1364/boe.7.003299] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2016] [Revised: 07/14/2016] [Accepted: 07/14/2016] [Indexed: 05/26/2023]
Abstract
The exposure of normal tissues to high radiation during cone-beam CT (CBCT) imaging increases the risk of cancer and genetic defects. Statistical iterative algorithms with the total variation (TV) penalty have been widely used for low dose CBCT reconstruction, with state-of-the-art performance in suppressing noise and preserving edges. However, TV is a first-order penalty and sometimes leads to the so-called staircase effect, particularly over regions with smooth intensity transition in the reconstruction images. A second-order penalty known as the Hessian penalty was recently used to replace TV to suppress the staircase effect in CBCT reconstruction at the cost of slightly blurring object edges. In this study, we proposed a new penalty, the TV-H, which combines TV and Hessian penalties for CBCT reconstruction in a structure-adaptive way. The TV-H penalty automatically differentiates the edges, gradual transition and uniform local regions within an image using the voxel gradient, and adaptively weights TV and Hessian according to the local image structures in the reconstruction process. Our proposed penalty retains the benefits of TV, including noise suppression and edge preservation. It also maintains the structures in regions with gradual intensity transition more successfully. A majorization-minimization (MM) approach was designed to optimize the objective energy function constructed with the TV-H penalty. The MM approach employed a quadratic upper bound of the original objective function, and the original optimization problem was changed to a series of quadratic optimization problems, which could be efficiently solved using the Gauss-Seidel update strategy. We tested the reconstruction algorithm on two simulated digital phantoms and two physical phantoms. Our experiments indicated that the TV-H penalty visually and quantitatively outperformed both TV and Hessian penalties.
Collapse
Affiliation(s)
- Qi Shi
- Key Laboratory of Image Processing and Intelligent Control of Ministry of Education of China, School of Automation, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Nanbo Sun
- Key Laboratory of Image Processing and Intelligent Control of Ministry of Education of China, School of Automation, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Tao Sun
- Key Laboratory of Image Processing and Intelligent Control of Ministry of Education of China, School of Automation, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Jing Wang
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390, USA;
| | - Shan Tan
- Key Laboratory of Image Processing and Intelligent Control of Ministry of Education of China, School of Automation, Huazhong University of Science and Technology, Wuhan 430074, China;
| |
Collapse
|
9
|
Zhang Z, Han X, Pearson E, Pelizzari C, Sidky EY, Pan X. Artifact reduction in short-scan CBCT by use of optimization-based reconstruction. Phys Med Biol 2016; 61:3387-406. [PMID: 27046218 DOI: 10.1088/0031-9155/61/9/3387] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Increasing interest in optimization-based reconstruction in research on, and applications of, cone-beam computed tomography (CBCT) exists because it has been shown to have to potential to reduce artifacts observed in reconstructions obtained with the Feldkamp-Davis-Kress (FDK) algorithm (or its variants), which is used extensively for image reconstruction in current CBCT applications. In this work, we carried out a study on optimization-based reconstruction for possible reduction of artifacts in FDK reconstruction specifically from short-scan CBCT data. The investigation includes a set of optimization programs such as the image-total-variation (TV)-constrained data-divergency minimization, data-weighting matrices such as the Parker weighting matrix, and objects of practical interest for demonstrating and assessing the degree of artifact reduction. Results of investigative work reveal that appropriately designed optimization-based reconstruction, including the image-TV-constrained reconstruction, can reduce significant artifacts observed in FDK reconstruction in CBCT with a short-scan configuration.
Collapse
Affiliation(s)
- Zheng Zhang
- Department of Radiology, The University of Chicago, Chicago, IL, USA
| | | | | | | | | | | |
Collapse
|
10
|
Vaegler S, Stsepankou D, Hesser J, Sauer O. Incorporation of local dependent reliability information into the Prior Image Constrained Compressed Sensing (PICCS) reconstruction algorithm. Z Med Phys 2015; 25:375-390. [DOI: 10.1016/j.zemedi.2015.09.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Revised: 05/30/2015] [Accepted: 09/01/2015] [Indexed: 10/24/2022]
|
11
|
Yan H, Wang X, Shi F, Bai T, Folkerts M, Cervino L, Jiang SB, Jia X. Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: cone/ring artifact correction and multiple GPU implementation. Med Phys 2015; 41:111912. [PMID: 25370645 DOI: 10.1118/1.4898324] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Compressed sensing (CS)-based iterative reconstruction (IR) techniques are able to reconstruct cone-beam CT (CBCT) images from undersampled noisy data, allowing for imaging dose reduction. However, there are a few practical concerns preventing the clinical implementation of these techniques. On the image quality side, data truncation along the superior-inferior direction under the cone-beam geometry produces severe cone artifacts in the reconstructed images. Ring artifacts are also seen in the half-fan scan mode. On the reconstruction efficiency side, the long computation time hinders clinical use in image-guided radiation therapy (IGRT). METHODS Image quality improvement methods are proposed to mitigate the cone and ring image artifacts in IR. The basic idea is to use weighting factors in the IR data fidelity term to improve projection data consistency with the reconstructed volume. In order to improve the computational efficiency, a multiple graphics processing units (GPUs)-based CS-IR system was developed. The parallelization scheme, detailed analyses of computation time at each step, their relationship with image resolution, and the acceleration factors were studied. The whole system was evaluated in various phantom and patient cases. RESULTS Ring artifacts can be mitigated by properly designing a weighting factor as a function of the spatial location on the detector. As for the cone artifact, without applying a correction method, it contaminated 13 out of 80 slices in a head-neck case (full-fan). Contamination was even more severe in a pelvis case under half-fan mode, where 36 out of 80 slices were affected, leading to poorer soft tissue delineation and reduced superior-inferior coverage. The proposed method effectively corrects those contaminated slices with mean intensity differences compared to FDK results decreasing from ∼497 and ∼293 HU to ∼39 and ∼27 HU for the full-fan and half-fan cases, respectively. In terms of efficiency boost, an overall 3.1 × speedup factor has been achieved with four GPU cards compared to a single GPU-based reconstruction. The total computation time is ∼30 s for typical clinical cases. CONCLUSIONS The authors have developed a low-dose CBCT IR system for IGRT. By incorporating data consistency-based weighting factors in the IR model, cone/ring artifacts can be mitigated. A boost in computational efficiency is achieved by multi-GPU implementation.
Collapse
Affiliation(s)
- Hao Yan
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, Dallas, Texas 75390
| | - Xiaoyu Wang
- Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037
| | - Feng Shi
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, Dallas, Texas 75390
| | - Ti Bai
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, Dallas, Texas 75390 and Institute of Image Processing and Pattern Recognition, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
| | - Michael Folkerts
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, Dallas, Texas 75390 and Department of Physics, University of California San Diego, La Jolla, California 92037
| | - Laura Cervino
- Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037
| | - Steve B Jiang
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, Dallas, Texas 75390
| | - Xun Jia
- Department of Radiation Oncology, The University of Texas Southwestern Medical Center, Dallas, Texas 75390
| |
Collapse
|
12
|
Han X, Pearson E, Pelizzari C, Al-Hallaq H, Sidky EY, Bian J, Pan X. Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy. Phys Med Biol 2015; 60:4601-33. [PMID: 26020490 DOI: 10.1088/0031-9155/60/12/4601] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data, optimization-based reconstruction has also been investigated for OBI CBCT. An optimization-based reconstruction involves numerous parameters, which can significantly impact reconstruction properties (or utility). The success of an optimization-based reconstruction for a particular class of practical applications thus relies strongly on appropriate selection of parameter values. In the work, we focus on tailoring the constrained-TV-minimization-based reconstruction, an optimization-based reconstruction previously shown of some potential for CBCT imaging conditions of practical interest, to OBI imaging through appropriate selection of parameter values. In particular, for given real data of phantoms and patient collected with OBI CBCT, we first devise utility metrics specific to OBI-quality-assurance tasks and then apply them to guiding the selection of parameter values in constrained-TV-minimization-based reconstruction. The study results show that the reconstructions are with improvement, relative to clinical FDK reconstruction, in both visualization and quantitative assessments in terms of the devised utility metrics.
Collapse
Affiliation(s)
- Xiao Han
- Department of Radiology, The University of Chicago, 5801 S Ellis Ave, Chicago, IL 60637, USA
| | | | | | | | | | | | | |
Collapse
|
13
|
Zhang H, Ouyang L, Ma J, Huang J, Chen W, Wang J. Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT. Med Phys 2014; 41:031906. [PMID: 24593724 DOI: 10.1118/1.4865782] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
PURPOSE To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT. METHODS In this study, the authors systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam onboard CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 to 1.6 mAs per projection at three fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT. RESULTS The analyses of the repeated measurements show that noise correlation coefficients are nonzero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second-order neighbors are 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. At the 2.0 mm resolution level in the axial-plane noise resolution tradeoff analysis, the noise level of the PWLS-Cor reconstruction is 6.3% lower than that of the PWLS-Dia reconstruction. CONCLUSIONS Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.
Collapse
Affiliation(s)
- Hua Zhang
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, China and Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas 75390
| | - Luo Ouyang
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas 75390
| | - Jianhua Ma
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, China
| | - Jing Huang
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, China
| | - Wufan Chen
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, China
| | - Jing Wang
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas 75390
| |
Collapse
|
14
|
Eklund A, Dufort P, Forsberg D, LaConte SM. Medical image processing on the GPU - past, present and future. Med Image Anal 2013; 17:1073-94. [PMID: 23906631 DOI: 10.1016/j.media.2013.05.008] [Citation(s) in RCA: 274] [Impact Index Per Article: 24.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2012] [Revised: 05/07/2013] [Accepted: 05/22/2013] [Indexed: 01/22/2023]
Abstract
Graphics processing units (GPUs) are used today in a wide range of applications, mainly because they can dramatically accelerate parallel computing, are affordable and energy efficient. In the field of medical imaging, GPUs are in some cases crucial for enabling practical use of computationally demanding algorithms. This review presents the past and present work on GPU accelerated medical image processing, and is meant to serve as an overview and introduction to existing GPU implementations. The review covers GPU acceleration of basic image processing operations (filtering, interpolation, histogram estimation and distance transforms), the most commonly used algorithms in medical imaging (image registration, image segmentation and image denoising) and algorithms that are specific to individual modalities (CT, PET, SPECT, MRI, fMRI, DTI, ultrasound, optical imaging and microscopy). The review ends by highlighting some future possibilities and challenges.
Collapse
Affiliation(s)
- Anders Eklund
- Virginia Tech Carilion Research Institute, Virginia Tech, Roanoke, USA.
| | | | | | | |
Collapse
|