Meyer S, Hu YC, Rimner A, Mechalakos J, Cerviño L, Zhang P. Deformable image registration uncertainty-encompassing dose accumulation for adaptive radiotherapy. Int J Radiat Oncol Biol Phys 2025:S0360-3016(25)00371-2. [PMID: 40239820 DOI: 10.1016/j.ijrobp.2025.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2024] [Revised: 03/03/2025] [Accepted: 04/04/2025] [Indexed: 04/18/2025]
Abstract
PURPOSE Deformable image registration (DIR) represents an inherently ill-posed problem, and its quality highly depends on the algorithm and user input, which can severely affect its applications in adaptive radiotherapy. We propose an automated framework for integrating DIR uncertainty into dose accumulation. METHODS A hyperparameter perturbation approach was applied to estimate an ensemble of deformation vector fields (DVFs) for a given CT to cone-beam CT (CBCT) DIR. For each voxel, a principal component analysis (PCA) was performed on the distribution of homologous points to construct voxel-specific DIR uncertainty confidence ellipsoids. During the resampling process for dose mapping, the complete dose within each ellipsoid was evaluated via interpolation to estimate the upper and lower dose limits for the particular voxel. We applied the proposed framework in a retrospective dose accumulation study of 20 lung cancer patients who underwent image-guided radiation therapy with weekly CBCTs. RESULTS The average computational time was around 30 min, making the approach clinically feasible for automated offline evaluations. The uncertainty (i.e., largest ellipsoid semi-axis length) for the fifth week CBCT DIR was 3.8±1.8 mm, 2.5±0.7 mm, 1.5±0.4 mm, 3.2±1.3 mm, and 4.5±1.8 mm for the GTV, esophagus, spinal cord, lungs, and heart, respectively. Confidence ellipsoids were markedly elongated, with the largest semi-axis 5.5 and 2.5 times longer than the other two axes. The dosimetric uncertainties were mainly within 4 Gy but exhibited significant spatial variation due to the interplay between dose gradient and DIR uncertainty. When DIR uncertainty was considered in dose accumulation, three cases exceeded institutional limits for dose-volume histogram metrics, highlighting the importance of considering the inherent uncertainty of DIR. CONCLUSIONS This framework has the potential to facilitate the clinical implementation of dose accumulation, which can improve clinical decision-making in adaptive radiotherapy and provide more personalized radiation therapy treatments.
Collapse
Affiliation(s)
- Sebastian Meyer
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
| | - Yu-Chi Hu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| | - Andreas Rimner
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| | - James Mechalakos
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| | - Laura Cerviño
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| | - Pengpeng Zhang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA
| |
Collapse
|
2
|
Zhang Y, Chan MKH. Clinical advantages of incorporating predicted weekly anatomy in IMPT optimization with reduced setup error. Med Phys 2024; 51:9207-9216. [PMID: 39298742 DOI: 10.1002/mp.17412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 08/26/2024] [Accepted: 08/31/2024] [Indexed: 09/22/2024] Open
Abstract
BACKGROUND In head and neck (H&N) cancer treatment, a conventional setup error (SE) of 3mm is often used in robust optimization (cRO3mm). However, cRO3mm may lead to excessive radiation doses to organs at risk (OARs) and does not purposefully compensate for interfractional anatomy variations. PURPOSE This study introduces a method using predicted images from an anatomical model and a reduced 1mm SE uncertainty for robust optimization (aRO1mm), aiming to decrease the dose to OARs without affecting the coverage of the clinical target volume (CTV). METHODS This retrospective study involved 10 nasopharynx radiotherapy patients. Validation CT scans (vCT) from treatment weeks 1 to 6 were analyzed. A predictive anatomical model, designed to capture the average anatomical changes over time, provided predicted CT images for weeks 1, 3, and 5. We compared three optimization scenarios: (1) aRO1mm, using three predicted images with 1mm setup shift and 3% range uncertainty, (2) cRO3mm, with a robust 3mm setup shift and 3% range uncertainty, and (3) cRO1mm, a robust 1mm setup shift and 3% range uncertainty. The accumulated dose to CTVs and serial organs was evaluated under these uncertainties, while parallel OARs were assessed using the accumulated nominal dose (without errors). RESULTS The accumulated volume receiving 94% of the prescribed dose (V94) for CTVs in cRO3mm exceeded 98%, meeting the clinical goal. For high-risk CTV, the minimum V94 was 96.44% in aRO1mm and 94.05% in cRO1mm. For low-risk CTV, these values were 97.68% in aRO1mm and 97.15% in cRO1mm. When comparing aRO1mm to cRO3mm on OARs, aRO1mm reduced normal tissue complication probability (NTCP) for grade ≥ $\ge$ 2 xerostomia and dysphagia by averages of 3.67% and 1.54%, respectively. CONCLUSION aRO1mm lowers the radiation dose to OARs compared to the traditional approach, while maintaining adequate dose coverage on the target area. This method offers an improved strategy for managing uncertainties in radiation therapy planning for H&N cancer, enhancing treatment effectiveness.
Collapse
Affiliation(s)
- Ying Zhang
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Mark Ka Heng Chan
- Department of Radiation Oncology, University Nebraska Medical Center, Omaha, USA
| |
Collapse
|
3
|
Tegtmeier RC, Kutyreff CJ, Smetanick JL, Hobbis D, Laughlin BS, Toesca DAS, Clouser EL, Rong Y. Custom-Trained Deep Learning-Based Auto-Segmentation for Male Pelvic Iterative CBCT on C-Arm Linear Accelerators. Pract Radiat Oncol 2024; 14:e383-e394. [PMID: 38325548 DOI: 10.1016/j.prro.2024.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/21/2023] [Accepted: 01/11/2024] [Indexed: 02/09/2024]
Abstract
PURPOSE The purpose of this investigation was to evaluate the clinical applicability of a commercial artificial intelligence-driven deep learning auto-segmentation (DLAS) tool on enhanced iterative cone beam computed tomography (iCBCT) acquisitions for intact prostate and prostate bed treatments. METHODS AND MATERIALS DLAS models were trained using 116 iCBCT data sets with manually delineated organs at risk (bladder, femoral heads, and rectum) and target volumes (intact prostate and prostate bed) adhering to institution-specific contouring guidelines. An additional 25 intact prostate and prostate bed iCBCT data sets were used for model testing. Segmentation accuracy relative to a reference structure set was quantified using various geometric comparison metrics and qualitatively evaluated by trained physicists and physicians. These results were compared with those obtained for an additional DLAS-based model trained on planning computed tomography (pCT) data sets and for a deformable image registration (DIR)-based automatic contour propagation method. RESULTS In most instances, statistically significant differences in the Dice similarity coefficient (DSC), 95% directed Hausdorff distance, and mean surface distance metrics were observed between the models, as the iCBCT-trained DLAS model outperformed the pCT-trained DLAS model and DIR-based method for all organs at risk and the intact prostate target volume. Mean DSC values for the proposed method were ≥0.90 for these volumes of interest. The iCBCT-trained DLAS model demonstrated a relatively suboptimal performance for the prostate bed segmentation, as the mean DSC value was <0.75 for this target contour. Overall, 90% of bladder, 93% of femoral head, 67% of rectum, and 92% of intact prostate contours generated by the proposed method were deemed clinically acceptable based on qualitative scoring, and approximately 63% of prostate bed contours required moderate or major manual editing to adhere to institutional contouring guidelines. CONCLUSIONS The proposed method presents the potential for improved segmentation accuracy and efficiency compared with the DIR-based automatic contour propagation method as commonly applied in CBCT-based dose evaluation and calculation studies.
Collapse
Affiliation(s)
- Riley C Tegtmeier
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | | | | | - Dean Hobbis
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona; Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri
| | - Brady S Laughlin
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | | | - Edward L Clouser
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona
| | - Yi Rong
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona.
| |
Collapse
|
4
|
Tian D, Sun G, Zheng H, Yu S, Jiang J. CT-CBCT deformable registration using weakly-supervised artifact-suppression transfer learning network. Phys Med Biol 2023; 68:165011. [PMID: 37433303 DOI: 10.1088/1361-6560/ace675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 07/11/2023] [Indexed: 07/13/2023]
Abstract
Objective.Computed tomography-cone-beam computed tomography (CT-CBCT) deformable registration has great potential in adaptive radiotherapy. It plays an important role in tumor tracking, secondary planning, accurate irradiation, and the protection of at-risk organs. Neural networks have been improving CT-CBCT deformable registration, and almost all registration algorithms based on neural networks rely on the gray values of both CT and CBCT. The gray value is a key factor in the loss function, parameter training, and final efficacy of the registration. Unfortunately, the scattering artifacts in CBCT affect the gray values of different pixels inconsistently. Therefore, the direct registration of the original CT-CBCT introduces artifact superposition loss.Approach. In this study, a histogram analysis method for the gray values was used. Based on an analysis of the gray value distribution characteristics of different regions in CT and CBCT, the degree of superposition of the artifact in the region of disinterest was found to be much higher than that in the region of interest. Moreover, the former was the main reason for artifact superposition loss. Consequently, a new weakly supervised two-stage transfer-learning network based on artifact suppression was proposed. The first stage was a pre-training network designed to suppress artifacts contained in the region of disinterest. The second stage was a convolutional neural network that registered the suppressed CBCT and CT.Main Results. Through a comparative test of the thoracic CT-CBCT deformable registration, whose data were collected from the Elekta XVI system, the rationality and accuracy after artifact suppression were confirmed to be significantly improved compared with the other algorithms without artifact suppression.Significance. This study proposed and verified a new deformable registration method with multi-stage neural networks, which can effectively suppress artifacts and further improve registration by incorporating a pre-training technique and an attention mechanism.
Collapse
Affiliation(s)
- Dingshu Tian
- University of Science and Technology of China, Hefei 230026, People's Republic of China
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
| | - Guangyao Sun
- SuperSafety Science and Technology Co., Ltd, Hefei 230088, People's Republic of China
- International Academy of Neutron Science, Qingdao 266199, People's Republic of China
| | - Huaqing Zheng
- International Academy of Neutron Science, Qingdao 266199, People's Republic of China
- Super Accuracy Science and Technology Co., Ltd, Nanjing 210044, People's Republic of China
| | - Shengpeng Yu
- SuperSafety Science and Technology Co., Ltd, Hefei 230088, People's Republic of China
- International Academy of Neutron Science, Qingdao 266199, People's Republic of China
| | - Jieqiong Jiang
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
| |
Collapse
|
5
|
Xie K, Gao L, Xi Q, Zhang H, Zhang S, Zhang F, Sun J, Lin T, Sui J, Ni X. New technique and application of truncated CBCT processing in adaptive radiotherapy for breast cancer. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 231:107393. [PMID: 36739623 DOI: 10.1016/j.cmpb.2023.107393] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 01/26/2023] [Accepted: 01/31/2023] [Indexed: 06/18/2023]
Abstract
OBJECTIVE A generative adversarial network (TCBCTNet) was proposed to generate synthetic computed tomography (sCT) from truncated low-dose cone-beam computed tomography (CBCT) and planning CT (pCT). The sCT was applied to the dose calculation of radiotherapy for patients with breast cancer. METHODS The low-dose CBCT and pCT images of 80 female thoracic patients were used for training. The CBCT, pCT, and replanning CT (rCT) images of 20 thoracic patients and 20 patients with breast cancer were used for testing. All patients were fixed in the same posture with a vacuum pad. The CBCT images were scanned under the Fast Chest M20 protocol with a 50% reduction in projection frames compared with the standard Chest M20 protocol. Rigid registration was performed between pCT and CBCT, and deformation registration was performed between rCT and CBCT. In the training stage of the TCBCTNet, truncated CBCT images obtained from complete CBCT images by simulation were used. The input of the CBCT→CT generator was truncated CBCT and pCT, and TCBCTNet was applied to patients with breast cancer after training. The accuracy of the sCT was evaluated by anatomy and dosimetry and compared with the generative adversarial network with UNet and ResNet as the generators (named as UnetGAN, ResGAN). RESULTS The three models could improve the image quality of CBCT and reduce the scattering artifacts while preserving the anatomical geometry of CBCT. For the chest test set, TCBCTNet achieved the best mean absolute error (MAE, 21.18±3.76 HU), better than 23.06±3.90 HU in UnetGAN and 22.47±3.57 HU in ResGAN. When applied to patients with breast cancer, TCBCTNet performance decreased, and MAE was 25.34±6.09 HU. Compared with rCT, sCT by TCBCTNet showed consistent dose distribution and subtle absolute dose differences between the target and the organ at risk. The 3D gamma pass rates were 98.98%±0.64% and 99.69%±0.22% at 2 mm/2% and 3 mm/3%, respectively. Ablation experiments confirmed that pCT and content loss played important roles in TCBCTNet. CONCLUSIONS High-quality sCT images could be synthesized from truncated low-dose CBCT and pCT by using the proposed TCBCTNet model. In addition, sCT could be used to accurately calculate the dose distribution for patients with breast cancer.
Collapse
Affiliation(s)
- Kai Xie
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou 213000, China; Jiangsu Province Engineering Research Center of Medical Physics, Changzhou 213000, China
| | - Liugang Gao
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou 213000, China; Jiangsu Province Engineering Research Center of Medical Physics, Changzhou 213000, China
| | - Qianyi Xi
- Center for Medical Physics, Nanjing Medical University, Changzhou 213003, China; Changzhou Key Laboratory of Medical Physics, Changzhou 213000, China
| | - Heng Zhang
- Center for Medical Physics, Nanjing Medical University, Changzhou 213003, China; Changzhou Key Laboratory of Medical Physics, Changzhou 213000, China
| | - Sai Zhang
- Center for Medical Physics, Nanjing Medical University, Changzhou 213003, China; Changzhou Key Laboratory of Medical Physics, Changzhou 213000, China
| | - Fan Zhang
- Center for Medical Physics, Nanjing Medical University, Changzhou 213003, China; Changzhou Key Laboratory of Medical Physics, Changzhou 213000, China
| | - Jiawei Sun
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou 213000, China; Jiangsu Province Engineering Research Center of Medical Physics, Changzhou 213000, China
| | - Tao Lin
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou 213000, China; Jiangsu Province Engineering Research Center of Medical Physics, Changzhou 213000, China
| | - Jianfeng Sui
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou 213000, China; Jiangsu Province Engineering Research Center of Medical Physics, Changzhou 213000, China
| | - Xinye Ni
- Radiotherapy Department, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou 213000, China; Jiangsu Province Engineering Research Center of Medical Physics, Changzhou 213000, China; Center for Medical Physics, Nanjing Medical University, Changzhou 213003, China; Changzhou Key Laboratory of Medical Physics, Changzhou 213000, China.
| |
Collapse
|
6
|
Zhang X, Uneri A, Huang Y, Jones CK, Witham TF, Helm PA, Siewerdsen JH. Deformable 3D-2D image registration and analysis of global spinal alignment in long-length intraoperative spine imaging. Med Phys 2022; 49:5715-5727. [PMID: 35762028 DOI: 10.1002/mp.15819] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 06/03/2022] [Accepted: 06/13/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Spinal deformation during surgical intervention (caused by patient positioning and/or correction of malalignment) confounds conventional navigation due to assumptions of rigid transformation. Moreover, the ability to accurately quantify spinal alignment in the operating room would provide assessment of the surgical product via metrics that correlate with clinical outcome. PURPOSE A method for deformable 3D-2D registration of preoperative CT to intraoperative long-length tomosynthesis images is reported for accurate 3D evaluation of device placement in the presence of spinal deformation and automated evaluation of global spinal alignment (GSA). METHODS Long-length tomosynthesis ("Long Film", LF) images were acquired using an O-arm™ imaging system (Medtronic, Minneapolis USA). A deformable 3D-2D patient registration was developed using multi-scale masking (proceeding from the full-length image to local subvolumes about each vertebra) to transform vertebral labels and planning information from preoperative CT to the LF images. Automatic measurement of GSA [Main Thoracic Kyphosis (MThK) and Lumbar Lordosis (LL)] was obtained using a spline fit to registered labels. The "Known-Component Registration" (KC-Reg) method for device registration was adapted to the multi-scale process for 3D device localization from orthogonal LF images. The multi-scale framework was evaluated using a deformable spine phantom in which pedicle screws were inserted, and deformations were induced over a range in LL ∼25-80°. Further validation was carried out in a cadaver study with implanted pedicle screws and a similar range of spinal deformation. The accuracy of patient and device registration was evaluated in terms of 3D translational error and target registration error (TRE), respectively, and the accuracy of automatic GSA measurements were compared to manual annotation. RESULTS Phantom studies demonstrated accurate registration via the multi-scale framework for all vertebral levels in both the neutral and deformed spine: median (interquartile range, IQR) patient registration error was 1.1 mm (0.7-1.9 mm IQR). Automatic measures of MThK and LL agreed with manual delineation within -1.1° ± 2.2° and 0.7° ± 2.0° (mean and standard deviation), respectively. Device registration error was 0.7 mm (0.4-1.0 mm IQR) at the screw tip and 0.9° (1.0°-1.5°) about the screw trajectory. Deformable 3D-2D registration significantly outperformed conventional rigid registration (p < 0.05), which exhibited device registration error of 2.1 mm (0.8-4.1 mm) and 4.1° (1.2°-9.5°). Cadaver studies verified performance under realistic conditions, demonstrating patient registration error of 1.6 mm (0.9-2.1 mm); MThK within -4.2° ± 6.8° and LL within 1.7° ± 3.5°; and device registration error of 0.8 mm (0.5-1.9 mm) and 0.7° (0.4°-1.2°) for the multi-scale deformable method, compared to 2.5 mm (1.0-7.9 mm) and 2.3° (1.6°-8.1°) for rigid registration (p < 0.05). CONCLUSION The deformable 3D-2D registration framework leverages long-length intraoperative imaging to achieve accurate patient and device registration over extended lengths of the spine (up to 64 cm) even with strong anatomical deformation. The method offers a new means for quantitative validation of spinal correction (intraoperative GSA measurement) and 3D verification of device placement in comparison to preoperative images and planning data. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Xiaoxuan Zhang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD
| | - Ali Uneri
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD
| | - Yixuan Huang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD
| | - Craig K Jones
- The Malone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD
| | - Timothy F Witham
- Department of Neurosurgery, Johns Hopkins University, Baltimore, MD
| | | | - Jeffrey H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD.,The Malone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD.,Department of Neurosurgery, Johns Hopkins University, Baltimore, MD
| |
Collapse
|
7
|
Zhang Y, McGowan Holloway S, Zoë Wilson M, Alshaikhi J, Tan W, Royle G, Bär E. DIR-based models to predict weekly anatomical changes in head and neck cancer proton therapy. Phys Med Biol 2022; 67:095001. [PMID: 35316795 PMCID: PMC10437002 DOI: 10.1088/1361-6560/ac5fe2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 03/17/2022] [Accepted: 03/22/2022] [Indexed: 11/12/2022]
Abstract
Objective. We proposed two anatomical models for head and neck patients to predict anatomical changes during the course of radiotherapy.Approach. Deformable image registration was used to build two anatomical models: (1) the average model (AM) simulated systematic progressive changes across the patient cohort; (2) the refined individual model (RIM) used a patient's CT images acquired during treatment to update the prediction for each individual patient. Planning CTs and weekly CTs were used from 20 nasopharynx patients. This dataset included 15 training patients and 5 test patients. For each test patient, a spot scanning proton plan was created. Models were evaluated using CT number differences, contours, proton spot location deviations and dose distributions.Main results. If no model was used, the CT number difference between the planning CT and the repeat CT at week 6 of treatment was on average 128.9 Hounsfield Units (HU) over the test population. This can be reduced to 115.5 HU using the AM, and to 110.5 HU using the RIM3(RIM, updated at week (3). When the predicted contours from the models were used, the average mean surface distance of parotid glands can be reduced from 1.98 (no model) to 1.16 mm (AM) and 1.19 mm (RIM3) at week 6. Using the proton spot range, the average anatomical uncertainty over the test population reduced from 4.47 ± 1.23 (no model) to 2.41 ± 1.12 mm (AM), and 1.89 ± 0.96 mm (RIM3). Based on the gamma analysis, the average gamma index over the test patients was improved from 93.87 ± 2.48 % (no model) to 96.16 ± 1.84% (RIM3) at week 6.Significance. The AM and the RIM both demonstrated the ability to predict anatomical changes during the treatment. The RIM can gradually refine the prediction of anatomical changes based on the AM. The proton beam spots provided an accurate and effective way for uncertainty evaluation.
Collapse
Affiliation(s)
- Ying Zhang
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Stacey McGowan Holloway
- CRUK RadNet Glasgow, University of Glasgow, Beatson West of Scotland Cancer Centre, Radiotherapy Physics, NHS Greater Glasgow and Clyde, Glasgow, United Kingdom
| | - Megan Zoë Wilson
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Jailan Alshaikhi
- Saudi Proton Therapy Center, King Fahad Medical City, Riyadh, Saudi Arabia
| | - Wenyong Tan
- Department of Oncology, Shenzhen Hospital of Southern Medical University Shenzhen 518101, People's Republic of China
| | - Gary Royle
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Esther Bär
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
- University College London Hospitals NHS Foundation Trust, Radiotherapy Physics, 250 Euston Road, London NW1 2PG, United Kingdom
| |
Collapse
|
8
|
Velten C, Goddard L, Jeong K, Garg MK, Tomé WA. Clinical Assessment of a Novel Ring Gantry Linear Accelerator-Mounted Helical Fan-Beam kVCT System. Adv Radiat Oncol 2022; 7:100862. [PMID: 35036634 PMCID: PMC8749200 DOI: 10.1016/j.adro.2021.100862] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 11/23/2021] [Indexed: 12/22/2022] Open
Abstract
Purpose To assess clinically relevant image quality metrics (IQMs) of helical fan beam kilovoltage (kV) fan beam computed tomography (CT). Methods and Materials kVCT IQMs were evaluated on an Accuray Radixact unit equipped with helical fan beam kVCT to assess the capabilities of this newly available modality. kVCT IQMs were evaluated and compared to a kVCT simulator and linear accelerator-based cone beam CTs (CBCT) using a commercial CBCT image quality phantom. kVCTs were acquired on the Accuray Radixact for all combinations of kVp and mAs in fine mode using a 440-mm field of view (FOV). Evaluated IQMs were spatial resolution, overall uniformity, subject contrast, contrast-to-noise ratio (CNR), and effective slice thickness. Imaging dose was assessed for planar kV imaging. Results On this kVCT system spatial resolution and contrast were consistent across all settings with 0.28 ± 0.03 lp/mm and 9.8% ± 0.7% (both 95% confidence interval). CNR strongly depended on selected mode (views per rotation) and body size (mA per view) and ranged between 7.9 and 34.9. Overall uniformity was greater than 97% for all settings. Large FOV was not found to substantially affect the IQMs whereas small FOV affected IQMs due to its effect on pitch. Technique-matched CT simulator scans were comparable for uniformity and contrast, while spatial resolution was higher (0.43 ± 0.06 lp/mm), and CNR was between 4% (140 kVp) and 51% (100 kVp) lower. For kV-CBCT, spatial resolutions ranging from 0.37 to 0.44 lp/mm were achieved with comparable contrast, CNR, and uniformity to kVCT. All kVCT scans exhibit imaging artifacts due to helical acquisition. Clinical acquisitions of megavoltage (MV) CT, kV-CBCT, and kVCT on the same patient showed improved and comparable image quality of kVCT compared to MVCT and kV-CBCT, respectively. Conclusions Helical fan beam kVCT allows for daily image guidance for localization and setup verification with comparable performance to existing kV-CBCT systems. Scan parameters must be selected carefully to maximize image quality for the desired tasks. Due to the large effective slice thicknesses for all parameter combinations, kVCT scans should not be used for simulation or planning of stereotactic procedures. Finally, improved image quality over MVCT has the potential to greatly improve manual and automated adaptive monitoring and planning.
Collapse
Affiliation(s)
- Christian Velten
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| | - Lee Goddard
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| | - Kyoungkeun Jeong
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| | - Madhur K Garg
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| | - Wolfgang A Tomé
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, New York
| |
Collapse
|
9
|
Cai M, Byrne M, Archibald-Heeren B, Metcalfe P, Rosenfeld A, Wang Y. Reducing axial truncation artifacts in iterative cone-beam CT for radiation therapy using a priori preconditioned information. Med Phys 2021; 48:7089-7098. [PMID: 34554587 DOI: 10.1002/mp.15248] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 07/29/2021] [Accepted: 09/14/2021] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Cone-beam computed tomography (CBCT) is increasingly utilized in radiation therapy for image guidance and adaptive applications. While iterative reconstruction algorithms have been shown to outperform traditional filtered back-projection methods in improving image quality and reducing imaging dose, they cannot handle data truncation in the axial view, which frequently occurs in the full-fan partial-trajectory acquisition mode. This proof-of-concept study presents a novel approach on truncation artifact reduction by utilizing a priori preconditioned information as the initial input for the iterative algorithm. METHODS Projections containing axial truncation were used for image reconstruction in extended axial field-of-view (AFOV) using the conjugate gradient least-squares (CGLS) algorithm. A priori information in the form of a planning fan-beam CT (FBCT) was repositioned in the expected CBCT imaging geometry, then further processed to dampen high-density features and convolved with a cubic Gaussian kernel to ensure differentiability for the gradient descent method. Anatomical and positional differences between the estimated and the actual imaging object were introduced to verify the efficacy of the proposed method. RESULTS Extending the reconstruction AFOV alone could partially reduce truncation artifact. Using a priori information directly resulted in ghosting artifact when there were anatomical and positional differences between the estimated and the actual imaging object. Using a priori preconditioned information was shown to effectively reduce truncation artifact and recover peripheral information. CONCLUSIONS Using a priori preconditioned information can effectively alleviate truncation artifact and assist recovery of peripheral information in iterative CBCT reconstruction.
Collapse
Affiliation(s)
- Meng Cai
- Icon Cancer Centre, Wahroonga, Australia.,Centre of Medical and Radiation Physics, University of Wollongong, Wollongong, Australia
| | | | | | - Peter Metcalfe
- Centre of Medical and Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Anatoly Rosenfeld
- Centre of Medical and Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Yang Wang
- Centre of Medical and Radiation Physics, University of Wollongong, Wollongong, Australia.,Icon Cancer Centre, Guangzhou, China
| |
Collapse
|
10
|
McKenzie EM, Tong N, Ruan D, Cao M, Chin RK, Sheng K. Using neural networks to extend cropped medical images for deformable registration among images with differing scan extents. Med Phys 2021; 48:4459-4471. [PMID: 34101198 DOI: 10.1002/mp.15039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 05/07/2021] [Accepted: 05/27/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Missing or discrepant imaging volume is a common challenge in deformable image registration (DIR). To minimize the adverse impact, we train a neural network to synthesize cropped portions of head and neck CT's and then test its use in DIR. METHODS Using a training dataset of 409 head and neck CT's, we trained a generative adversarial network to take in a cropped 3D image and output an image with synthesized anatomy in the cropped region. The network used a 3D U-Net generator along with Visual Geometry Group (VGG) deep feature losses. To test our technique, for each of the 53 test volumes, we used Elastix to deformably register combinations of a randomly cropped, full, and synthetically full volume to a single cropped, full, and synthetically full target volume. We additionally tested our method's robustness to crop extent by progressively increasing the amount of cropping, synthesizing the missing anatomy using our network, and then performing the same registration combinations. Registration performance was measured using 95% Hausdorff distance across 16 contours. RESULTS We successfully trained a network to synthesize missing anatomy in superiorly and inferiorly cropped images. The network can estimate large regions in an incomplete image, far from the cropping boundary. Registration using our estimated full images was not significantly different from registration using the original full images. The average contour matching error for full image registration was 9.9 mm, whereas our method was 11.6, 12.1, and 13.6 mm for synthesized-to-full, full-to-synthesized, and synthesized-to-synthesized registrations, respectively. In comparison, registration using the cropped images had errors of 31.7 mm and higher. Plotting the registered image contour error as a function of initial preregistered error shows that our method is robust to registration difficulty. Synthesized-to-full registration was statistically independent of cropping extent up to 18.7 cm superiorly cropped. Synthesized-to-synthesized registration was nearly independent, with a -0.04 mm of change in average contour error for every additional millimeter of cropping. CONCLUSIONS Different or inadequate in scan extent is a major cause of DIR inaccuracies. We address this challenge by training a neural network to complete cropped 3D images. We show that with image completion, the source of DIR inaccuracy is eliminated, and the method is robust to varying crop extent.
Collapse
Affiliation(s)
- Elizabeth M McKenzie
- Department of Radiation Oncology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA
| | - Nuo Tong
- Department of Radiation Oncology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA
| | - Dan Ruan
- Department of Radiation Oncology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA
| | - Minsong Cao
- Department of Radiation Oncology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA
| | - Robert K Chin
- Department of Radiation Oncology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA
| | - Ke Sheng
- Department of Radiation Oncology, David Geffen School of Medicine, University of California, Los Angeles, CA, USA
| |
Collapse
|
11
|
Bjarnason TA, Rees R, Kainz J, Le LH, Stewart EE, Preston B, Elbakri I, Fife IAJ, Lee T, Gagnon IMB, Arsenault C, Therrien P, Kendall E, Tonkopi E, Cottreau M, Aldrich JE. An international survey on the clinical use of rigid and deformable image registration in radiotherapy. J Appl Clin Med Phys 2020; 21:10-24. [PMID: 32915492 PMCID: PMC7075391 DOI: 10.1002/acm2.12957] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 01/13/2020] [Accepted: 05/14/2020] [Indexed: 12/16/2022] Open
Abstract
OBJECTIVES Rigid image registration (RIR) and deformable image registration (DIR) are widely used in radiotherapy. This project aims to capture current international approaches to image registration. METHODS A survey was designed to identify variations in use, resources, implementation, and decision-making criteria for clinical image registration. This was distributed to radiotherapy centers internationally in 2018. RESULTS There were 57 responses internationally, from the Americas (46%), Australia/New Zealand (32%), Europe (12%), and Asia (10%). Rigid image registration and DIR were used clinically for computed tomography (CT)-CT registration (96% and 51%, respectively), followed by CT-PET (81% and 47%), CT-CBCT (84% and 19%), CT-MR (93% and 19%), MR-MR (49% and 5%), and CT-US (9% and 0%). Respondent centers performed DIR using dedicated software (75%) and treatment planning systems (29%), with 84% having some form of DIR software. Centers have clinically implemented DIR for atlas-based segmentation (47%), multi-modality treatment planning (65%), and dose deformation (63%). The clinical use of DIR for multi-modality treatment planning and accounting for retreatments was considered to have the highest benefit-to-risk ratio (69% and 67%, respectively). CONCLUSIONS This survey data provides useful insights on where, when, and how image registration has been implemented in radiotherapy centers around the world. DIR is mainly in clinical use for CT-CT (51%) and CT-PET (47%) for the head and neck (43-57% over all use cases) region. The highest benefit-risk ratio for clinical use of DIR was for multi-modality treatment planning and accounting for retreatments, which also had higher clinical use than for adaptive radiotherapy and atlas-based segmentation.
Collapse
Affiliation(s)
- Thorarin A. Bjarnason
- Medical ImagingInterior Health AuthorityKelownaBCCanada
- RadiologyUniversity of British ColumbiaVancouverBCCanada
- PhysicsUniversity of British Columbia OkanaganKelownaBCCanada
| | - Robert Rees
- Occupational Health & SafetyYukon Workers' Compensation Health and Safety BoardWhitehorseYKCanada
| | - Judy Kainz
- Workers' Safety and Compensation Commission for Northwest Territories and NunavutYellowknifeNTCanada
| | - Lawrence H. Le
- Diagnostic ImagingAlberta Health ServicesCalgaryABCanada
- Radiology and Diagnostic ImagingUniversity of AlbertaEdmontonABCanada
| | | | - Brent Preston
- Radiation Safety UnitGovernment of SaskatchewanSaskatoonSKCanada
| | - Idris Elbakri
- Cancer Care ManitobaWinnipegMBCanada
- Physics and AstronomyUniversity of ManitobaWinnipegMBCanada
- RadiologyUniversity of ManitobaWinnipegMBCanada
| | - Ingvar A. J. Fife
- Cancer Care ManitobaWinnipegMBCanada
- Physics and AstronomyUniversity of ManitobaWinnipegMBCanada
- RadiologyUniversity of ManitobaWinnipegMBCanada
| | - Ting‐Yim Lee
- St Joseph’s Health Care LondonLondonONCanada
- Lawson Research InstituteLondonONCanada
- Medical ImagingMedical Biophysics, OncologyRobarts Research InstituteUniversity of Western OntarioLondonONCanada
| | | | - Clément Arsenault
- Hôpital Dr Georges–L. DumontCentre d'Oncologie Dr Léon–RichardMonctonNBCanada
| | | | | | - Elena Tonkopi
- Nova Scotia Health AuthorityHalifaxNSCanada
- Diagnostic RadiologyDalhousie UniversityHalifaxNSCanada
- Radiation OncologyDalhousie UniversityHalifaxNSCanada
| | | | | |
Collapse
|
12
|
Yuan Z, Rong Y, Benedict SH, Daly ME, Qiu J, Yamamoto T. "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy. J Appl Clin Med Phys 2019; 21:88-94. [PMID: 31816170 PMCID: PMC6964750 DOI: 10.1002/acm2.12793] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Revised: 02/04/2019] [Accepted: 11/17/2019] [Indexed: 12/25/2022] Open
Abstract
Purpose Adaptive radiotherapy (ART) has potential to reduce toxicity and facilitate safe dose escalation. Dose calculations with the planning CT deformed to cone beam CT (CBCT) have shown promise for estimating the “dose of the day”. The purpose of this study is to investigate the “dose of the day” calculation accuracy based on CBCT and deformable image registration (DIR) for lung cancer radiotherapy. Methods A total of 12 lung cancer patients were identified, for which daily CBCT imaging was performed for treatment positioning. A re‐planning CT (rCT) was acquired after 20 Gy for all patients. A virtual CT (vCT) was created by deforming initial planning CT (pCT) to the simulated CBCT that was generated from deforming CBCT to rCT acquired on the same day. Treatment beams from the initial plan were copied to the vCT and rCT for dose calculation. Dosimetric agreement between vCT‐based and rCT‐based accumulated doses was evaluated using the Bland‐Altman analysis. Results Mean differences in dose‐volume metrics between vCT and rCT were smaller than 1.5%, and most discrepancies fell within the range of ± 5% for the target volume, lung, esophagus, and heart. For spinal cord Dmax, a large mean difference of −5.55% was observed, which was largely attributed to very limited CBCT image quality (e.g., truncation artifacts). Conclusion This study demonstrated a reasonable agreement in dose‐volume metrics between dose accumulation based on vCT and rCT, with the exception for cases with poor CBCT image quality. These findings suggest potential utility of vCT for providing a reasonable estimate of the “dose of the day”, and thus facilitating the process of ART for lung cancer.
Collapse
Affiliation(s)
- Zilong Yuan
- Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA, USA.,Department of Radiology, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yi Rong
- Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA, USA
| | - Stanley H Benedict
- Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA, USA
| | - Megan E Daly
- Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA, USA
| | - Jianfeng Qiu
- Medical Engineering and Technology Research Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China
| | - Tokihiro Yamamoto
- Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA, USA
| |
Collapse
|
13
|
Loi G, Fusella M, Vecchi C, Menna S, Rosica F, Gino E, Maffei N, Menghi E, Savini A, Roggio A, Radici L, Cagni E, Lucio F, Strigari L, Strolin S, Garibaldi C, Romanò C, Piovesan M, Franco P, Fiandra C. Computed Tomography to Cone Beam Computed Tomography Deformable Image Registration for Contour Propagation Using Head and Neck, Patient-Based Computational Phantoms: A Multicenter Study. Pract Radiat Oncol 2019; 10:125-132. [PMID: 31786233 DOI: 10.1016/j.prro.2019.11.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 10/22/2019] [Accepted: 11/12/2019] [Indexed: 12/14/2022]
Abstract
PURPOSE To investigate the performance of various algorithms for deformable image registration (DIR) for propagating regions of interest (ROIs) using multiple commercial platforms, from computed tomography to cone beam computed tomography (CBCT) and megavoltage computed tomography. METHODS AND MATERIALS Fourteen institutions participated in the study using 5 commercial platforms: RayStation (RaySearch Laboratories, Stockholm, Sweden), MIM (Cleveland, OH), VelocityAI and SmartAdapt (Varian Medical Systems, Palo Alto, CA), and ABAS (Elekta AB, Stockholm, Sweden). Algorithms were tested on synthetic images generated with the ImSimQA (Oncology Systems Limited, Shrewsbury, UK) package by applying 2 specific deformation vector fields (DVF) to real head and neck patient datasets. On-board images from 3 systems were used: megavoltage computed tomography from Tomotherapy and 2 kinds of CBCT from a clinical linear accelerator. Image quality of the system was evaluated. The algorithms' accuracy was assessed by comparing the DIR-mapped ROIs returned by each center with those of the reference, using the Dice similarity coefficient and mean distance to conformity metrics. Statistical inference on the validation results was carried out to identify the prognostic factors of DIR performance. RESULTS Analyzing 840 DIR-mapped ROIs returned by the centers, it was demonstrated that DVF intensity and image quality were significant prognostic factors of DIR performance. The accuracy of the propagated contours was generally high, and acceptable DIR performance can be obtained with lower-dose CBCT image protocols. CONCLUSIONS The performance of the systems proved to be image quality specific, depending on the DVF type and only partially on the platforms. All systems proved to be robust against image artifacts and noise, except the demon-based software.
Collapse
Affiliation(s)
- Gianfranco Loi
- Department of Medical Physics, University Hospital "Maggiore della Carità," Novara, Italy
| | - Marco Fusella
- Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, Padua, Italy.
| | | | - Sebastiano Menna
- Fondazione Policlinico Universitario A. Gemelli IRCCS, UOC di Fisica Sanitaria, Dipartimento di diagnostica per immagini, radioterapia oncologica ed ematologia, Rome, Italy
| | | | - Eva Gino
- SC Fisica Sanitaria, A.O. Ordine Mauriziano di Torino, Italy
| | - Nicola Maffei
- Department of Medical Physics, A.O. U. di Modena, Modena, Italy; University of Turin, Post Graduate School in Medical Physics, Turin, Italy
| | - Enrico Menghi
- Medical Physics Department, Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS, Meldola, FC, Italy
| | - Alessandro Savini
- Medical Physics Department, Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS, Meldola, FC, Italy
| | - Antonella Roggio
- Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, Padua, Italy
| | - Lorenzo Radici
- Ospedale regionale "Umberto Parini" Azienda USL VDA, Fisica Sanitaria, Italy
| | - Elisabetta Cagni
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy; School of Engineering, Cardiff University, Cardiff, Wales, UK
| | | | - Lidia Strigari
- Department of Medical Physics, St. Orsola-Malpighi Hospital, Bologna, Italy
| | | | - Cristina Garibaldi
- IEO, European Institute of Oncology IRCCS, Unit of Medical Physics, Milan, Italy
| | - Chiara Romanò
- IEO, European Institute of Oncology IRCCS, Unit of Medical Physics, Milan, Italy
| | | | | | - Christian Fiandra
- University of Turin, Department of Oncology, Turin, Italy; School of Bioengineering and Medical-Surgical Sciences, Politecnico di Torino, Turin, Italy
| |
Collapse
|
14
|
Using an on-board cone-beam computed tomography scanner as an imaging modality for gel dosimetry: A feasibility study. Appl Radiat Isot 2019; 151:242-246. [DOI: 10.1016/j.apradiso.2019.06.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Revised: 06/09/2019] [Accepted: 06/10/2019] [Indexed: 10/26/2022]
|
15
|
Abstract
As deformable image registration makes its way into the clinical routine, the summation of doses from fractionated treatment regimens to evaluate cumulative doses to targets and healthy tissues is also becoming a frequently utilized tool in the context of image-guided adaptive radiotherapy. Accounting for daily geometric changes using deformable image registration and dose accumulation potentially enables a better understanding of dose-volume-effect relationships, with the goal of translation of this knowledge to personalization of treatment, to further enhance treatment outcomes. Treatment adaptation involving image deformation requires patient-specific quality assurance of the image registration and dose accumulation processes, to ensure that uncertainties in the 3D dose distributions are identified and appreciated from a clinical relevance perspective. While much research has been devoted to identifying and managing the uncertainties associated with deformable image registration and dose accumulation approaches, there are still many unanswered questions. Here, we provide a review of current deformable image registration and dose accumulation techniques, and related clinical application. We also discuss salient issues that need to be deliberated when applying deformable algorithms for dose mapping and accumulation in the context of adaptive radiotherapy and response assessment.
Collapse
|
16
|
Schröder L, Stankovic U, Remeijer P, Sonke JJ. Evaluating the impact of cone-beam computed tomography scatter mitigation strategies on radiotherapy dose calculation accuracy. Phys Imaging Radiat Oncol 2019; 10:35-40. [PMID: 33458266 PMCID: PMC7807872 DOI: 10.1016/j.phro.2019.04.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 03/27/2019] [Accepted: 04/03/2019] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND AND PURPOSE The scatter induced image quality degradation of cone-beam computed tomography (CBCT) prevents more advanced applications in radiotherapy. We evaluated the dose calculation accuracy on CBCT of various disease sites using different scatter mitigation strategies. MATERIALS AND METHODS CBCT scans of two patient cohorts (C1, C2) were reconstructed using a uniform (USC) and an iterative scatter correction (ISC) method, combined with an anti-scatter grid (ASG). Head and neck (H&N), lung, pelvic region, and prostate patients were included. To achieve a high accuracy Hounsfield unit and physical density calibrations were performed. The dose distributions of the original treatment plans were analyzed with the γ evaluation method using criteria of 1%/2 mm using the planning CT as the reference. The investigated parameters were the mean γ (γmean), the points in agreement (Pγ≤1) and the 99th percentile (γ1%). RESULTS Significant differences between USC and ISC in C1 were found for the lung and prostate, where the latter using the ISC produced the best results with medians of 0.38, 98%, and 1.1 for γmean, Pγ≤1 and γ1%, respectively. For C2 the ISC with ASG showed an improvement for all imaging sites. The lung demonstrated the largest relative increase in accuracy with improvements between 48% and 54% for the medians of γmean, Pγ≤1 and γ1%. CONCLUSIONS The introduced method demonstrated high dosimetric accuracy for H&N, prostate and pelvic region if an ASG is applied. A significantly lower accuracy was seen for lung. The ISC yielded a higher robustness against scatter variations than the USC.
Collapse
Affiliation(s)
- Lukas Schröder
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Uros Stankovic
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Peter Remeijer
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Jan-Jakob Sonke
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| |
Collapse
|
17
|
Sun B, Yang D, Lam D, Zhang T, Dvergsten T, Bradley J, Mutic S, Zhao T. Toward adaptive proton therapy guided with a mobile helical CT scanner. Radiother Oncol 2018; 129:479-485. [PMID: 30314717 DOI: 10.1016/j.radonc.2018.08.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 08/21/2018] [Accepted: 08/26/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE To evaluate the feasibility of image-guided adaptive proton therapy (IGAPT) with a mobile helical-CT without rails. METHOD CT images were acquired with a 32-slice mobile CT (mCT) scanning through a 6 degree-of-freedom robotic couch rotated isocentrically 90 degrees from an initial setup position. The relationship between the treatment isocenter and the mCT imaging isocenter was established by a stereotactic reference frame attached to the treatment couch. Imaging quality, geometric integrity and localization accuracy were evaluated according to AAPM TG-66. Accuracy of relative stopping power ratio (RSPR) was evaluated by comparing water equivalent distance (WED) and dose calculations on anthropomorphic phantoms to that of planning CT (pCT). Feasibility of image-guided adaptive proton therapy was demonstrated on fractional images acquired with the mCT scanner. RESULTS mCT images showed slightly lower spatial resolution and a higher contrast-to-noise ratio compared to pCT images from the standard helical CT scanner. The geometric accuracy of the mCT was <1 mm. Localization accuracy was <0.4 mm and <0.3° with respect to 2DkV/kV matching. WED differences between mCT and pCT images were negligible, with discrepancies of 0.8 ± 0.6 mm and 1.3 ± 0.9 mm for brain and lung phantoms respectively. 3D gamma analysis (3% and 3 mm) passing rate was >95% on dose computed on mCT, with respect to dose calculation on pCT. CONCLUSION Our study has demonstrated that the geometric integrity, image quality and RSPR accuracy of the mCT are sufficient for IGAPT.
Collapse
Affiliation(s)
- Baozhou Sun
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, United States.
| | - Deshan Yang
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, United States
| | - Dao Lam
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, United States
| | - Tiezhi Zhang
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, United States
| | - Thomas Dvergsten
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, United States
| | - Jeffrey Bradley
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, United States
| | - Sasa Mutic
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, United States
| | - Tianyu Zhao
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, United States
| |
Collapse
|
18
|
Pei Y, Yi Y, Ma G, Kim TK, Guo Y, Xu T, Zha H. Spatially Consistent Supervoxel Correspondences of Cone-Beam Computed Tomography Images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:2310-2321. [PMID: 29993683 DOI: 10.1109/tmi.2018.2829629] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Establishing dense correspondences of cone-beam computed tomography (CBCT) images is a crucial step for the attribute transfer and morphological variation assessment in clinical orthodontics. In this paper, a novel method, unsupervised spatially consistent clustering forest, is proposed to tackle the challenges for automatic supervoxel-wise correspondences of CBCT images. A complexity analysis of the proposed method with respect to the clustering hypotheses is provided with a data-dependent learning guarantee. The learning bound considers both the sequential tree traversals determined by questions stored in branch nodes and the clustering compactness of leaf nodes. A novel tree-pruning algorithm, guided by the learning bound, is also proposed to remove locally inconsistent leaf nodes. The resulting forest yields spatially consistent affinity estimations, thanks to the pruning penalizing trees with inconsistent leaf assignments and the combinational contextual feature channels used to learn the forest. A forest-based metric is utilized to derive the pairwise affinities and dense correspondences of CBCT images. The proposed method has been applied to the label propagation of clinically captured CBCT images. In the experiments, the method outperforms variants of both supervised and unsupervised forest-based methods and state-of-the-art label-propagation methods, achieving the mean dice similarity coefficients of 0.92, 0.89, 0.94, and 0.93 for the mandible, the maxilla, the zygoma arch, and the teeth data, respectively.
Collapse
|
19
|
Barateau A, Céleste M, Lafond C, Henry O, Couespel S, Simon A, Acosta O, de Crevoisier R, Périchon N. Calcul de dose de radiothérapie à partir de tomographies coniques : état de l’art. Cancer Radiother 2018; 22:85-100. [PMID: 29276135 DOI: 10.1016/j.canrad.2017.07.050] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 06/06/2017] [Accepted: 07/07/2017] [Indexed: 01/26/2023]
|
20
|
Liu C, Kim J, Kumarasiri A, Mayyas E, Brown SL, Wen N, Siddiqui F, Chetty IJ. An automated dose tracking system for adaptive radiation therapy. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 154:1-8. [PMID: 29249335 DOI: 10.1016/j.cmpb.2017.11.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 10/23/2017] [Accepted: 11/01/2017] [Indexed: 06/07/2023]
Abstract
BACKGROUND AND OBJECTIVE The implementation of adaptive radiation therapy (ART) into routine clinical practice is technically challenging and requires significant resources to perform and validate each process step. The objective of this report is to identify the key components of ART, to illustrate how a specific automated procedure improves efficiency, and to facilitate the routine clinical application of ART. METHODS Data was used from patient images, exported from a clinical database and converted to an intermediate format for point-wise dose tracking and accumulation. The process was automated using in-house developed software containing three modularized components: an ART engine, user interactive tools, and integration tools. The ART engine conducts computing tasks using the following modules: data importing, image pre-processing, dose mapping, dose accumulation, and reporting. In addition, custom graphical user interfaces (GUIs) were developed to allow user interaction with select processes such as deformable image registration (DIR). A commercial scripting application programming interface was used to incorporate automated dose calculation for application in routine treatment planning. Each module was considered an independent program, written in C++or C#, running in a distributed Windows environment, scheduled and monitored by integration tools. RESULTS The automated tracking system was retrospectively evaluated for 20 patients with prostate cancer and 96 patients with head and neck cancer, under institutional review board (IRB) approval. In addition, the system was evaluated prospectively using 4 patients with head and neck cancer. Altogether 780 prostate dose fractions and 2586 head and neck cancer dose fractions went processed, including DIR and dose mapping. On average, daily cumulative dose was computed in 3 h and the manual work was limited to 13 min per case with approximately 10% of cases requiring an additional 10 min for image registration refinement. CONCLUSIONS An efficient and convenient dose tracking system for ART in the clinical setting is presented. The software and automated processes were rigorously evaluated and validated using patient image datasets. Automation of the various procedures has improved efficiency significantly, allowing for the routine clinical application of ART for improving radiation therapy effectiveness.
Collapse
Affiliation(s)
- Chang Liu
- Department of Radiation Oncology, Josephine Ford Cancer Institute, Henry Ford Health System, Detroit, MI, USA.
| | - Jinkoo Kim
- Department of Radiation Oncology, Stony Brook University, NY, USA
| | - Akila Kumarasiri
- Department of Radiation Oncology, Josephine Ford Cancer Institute, Henry Ford Health System, Detroit, MI, USA
| | - Essa Mayyas
- Department of Radiation Oncology, Josephine Ford Cancer Institute, Henry Ford Health System, Detroit, MI, USA
| | - Stephen L Brown
- Department of Radiation Oncology, Josephine Ford Cancer Institute, Henry Ford Health System, Detroit, MI, USA
| | - Ning Wen
- Department of Radiation Oncology, Josephine Ford Cancer Institute, Henry Ford Health System, Detroit, MI, USA
| | - Farzan Siddiqui
- Department of Radiation Oncology, Josephine Ford Cancer Institute, Henry Ford Health System, Detroit, MI, USA
| | - Indrin J Chetty
- Department of Radiation Oncology, Josephine Ford Cancer Institute, Henry Ford Health System, Detroit, MI, USA
| |
Collapse
|
21
|
Sarkar S, Wahi P, Munshi P. Dual scan CT image recovery from truncated projections. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:123704. [PMID: 29289161 DOI: 10.1063/1.5000928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
There are computerized tomography (CT) scanners available commercially for imaging small objects and they are often categorized as mini-CT X-ray machines. One major limitation of these machines is their inability to scan large objects with good image quality because of the truncation of projection data. An algorithm is proposed in this work which enables such machines to scan large objects while maintaining the quality of the recovered image.
Collapse
Affiliation(s)
- Shubhabrata Sarkar
- Nuclear Engineering and Technology Programme, Indian Institute of Technology Kanpur, Kanpur 208016, India
| | - Pankaj Wahi
- Nuclear Engineering and Technology Programme, Indian Institute of Technology Kanpur, Kanpur 208016, India
| | - Prabhat Munshi
- Nuclear Engineering and Technology Programme, Indian Institute of Technology Kanpur, Kanpur 208016, India
| |
Collapse
|
22
|
Lim-Reinders S, Keller BM, Al-Ward S, Sahgal A, Kim A. Online Adaptive Radiation Therapy. Int J Radiat Oncol Biol Phys 2017; 99:994-1003. [DOI: 10.1016/j.ijrobp.2017.04.023] [Citation(s) in RCA: 81] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Accepted: 04/14/2017] [Indexed: 10/19/2022]
|
23
|
Liao Y, Wang L, Xu X, Chen H, Chen J, Zhang G, Lei H, Wang R, Zhang S, Gu X, Zhen X, Zhou L. An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy. Med Phys 2017; 44:2369-2378. [PMID: 28317122 DOI: 10.1002/mp.12229] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 11/23/2016] [Accepted: 03/12/2017] [Indexed: 11/06/2022] Open
Affiliation(s)
- Yuliang Liao
- Department of Biomedical Engineering; Southern Medical University; Guangzhou Guangdong 510515 China
| | - Linjing Wang
- Radiotherapy Center; Affiliated Cancer Hospital & Institute of Guangzhou Medical University; Guangzhou Guangdong 510095 China
| | - Xiangdong Xu
- Department of Radiology; Guangzhou First People's Hospital; Guangzhou Medical University; Guangzhou Guangdong 510180 China
| | - Haibin Chen
- Department of Biomedical Engineering; Southern Medical University; Guangzhou Guangdong 510515 China
| | - Jiawei Chen
- Department of Biomedical Engineering; Southern Medical University; Guangzhou Guangdong 510515 China
| | - Guoqian Zhang
- Radiotherapy Center; Affiliated Cancer Hospital & Institute of Guangzhou Medical University; Guangzhou Guangdong 510095 China
| | - Huaiyu Lei
- Radiotherapy Center; Affiliated Cancer Hospital & Institute of Guangzhou Medical University; Guangzhou Guangdong 510095 China
| | - Ruihao Wang
- Radiotherapy Center; Affiliated Cancer Hospital & Institute of Guangzhou Medical University; Guangzhou Guangdong 510095 China
| | - Shuxu Zhang
- Radiotherapy Center; Affiliated Cancer Hospital & Institute of Guangzhou Medical University; Guangzhou Guangdong 510095 China
| | - Xuejun Gu
- Department of Radiation Oncology; The University of Texas; Southwestern Medical Center; Dallas Texas 75390 USA
| | - Xin Zhen
- Department of Biomedical Engineering; Southern Medical University; Guangzhou Guangdong 510515 China
| | - Linghong Zhou
- Department of Biomedical Engineering; Southern Medical University; Guangzhou Guangdong 510515 China
| |
Collapse
|
24
|
Li X, Zhang Y, Shi Y, Wu S, Xiao Y, Gu X, Zhen X, Zhou L. Comprehensive evaluation of ten deformable image registration algorithms for contour propagation between CT and cone-beam CT images in adaptive head & neck radiotherapy. PLoS One 2017; 12:e0175906. [PMID: 28414799 PMCID: PMC5393623 DOI: 10.1371/journal.pone.0175906] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Accepted: 04/02/2017] [Indexed: 01/16/2023] Open
Abstract
Deformable image registration (DIR) is a critical technic in adaptive radiotherapy (ART) for propagating contours between planning computerized tomography (CT) images and treatment CT/cone-beam CT (CBCT) images to account for organ deformation for treatment re-planning. To validate the ability and accuracy of DIR algorithms in organ at risk (OAR) contour mapping, ten intensity-based DIR strategies, which were classified into four categories—optical flow-based, demons-based, level-set-based and spline-based—were tested on planning CT and fractional CBCT images acquired from twenty-one head & neck (H&N) cancer patients who underwent 6~7-week intensity-modulated radiation therapy (IMRT). Three similarity metrics, i.e., the Dice similarity coefficient (DSC), the percentage error (PE) and the Hausdorff distance (HD), were employed to measure the agreement between the propagated contours and the physician-delineated ground truths of four OARs, including the vertebra (VTB), the vertebral foramen (VF), the parotid gland (PG) and the submandibular gland (SMG). It was found that the evaluated DIRs in this work did not necessarily outperform rigid registration. DIR performed better for bony structures than soft-tissue organs, and the DIR performance tended to vary for different ROIs with different degrees of deformation as the treatment proceeded. Generally, the optical flow-based DIR performed best, while the demons-based DIR usually ranked last except for a modified demons-based DISC used for CT-CBCT DIR. These experimental results suggest that the choice of a specific DIR algorithm depends on the image modality, anatomic site, magnitude of deformation and application. Therefore, careful examinations and modifications are required before accepting the auto-propagated contours, especially for automatic re-planning ART systems.
Collapse
Affiliation(s)
- Xin Li
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, China
| | - Yuyu Zhang
- Department of Radiotherapy Oncology, The First Hospital of Jilin University, Changchun, Jilin, China
| | - Yinghua Shi
- Department of Radiotherapy Oncology, The First Hospital of Jilin University, Changchun, Jilin, China
| | - Shuyu Wu
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, China
| | - Yang Xiao
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, China
| | - Xuejun Gu
- Department of Radiotherapy Oncology, The University of Texas, Southwestern Medical Center, Dallas, Texas, United States of America
| | - Xin Zhen
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, China
- * E-mail: (XZ); (LZ)
| | - Linghong Zhou
- Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, China
- * E-mail: (XZ); (LZ)
| |
Collapse
|
25
|
Abstract
This work focuses on developing a 2D Canny edge-based deformable image registration (Canny DIR) algorithm to register in vivo white light images taken at various time points. This method uses a sparse interpolation deformation algorithm to sparsely register regions of the image with strong edge information. A stability criterion is enforced which removes regions of edges that do not deform in a smooth uniform manner. Using a synthetic mouse surface ground truth model, the accuracy of the Canny DIR algorithm was evaluated under axial rotation in the presence of deformation. The accuracy was also tested using fluorescent dye injections, which were then used for gamma analysis to establish a second ground truth. The results indicate that the Canny DIR algorithm performs better than rigid registration, intensity corrected Demons, and distinctive features for all evaluation matrices and ground truth scenarios. In conclusion Canny DIR performs well in the presence of the unique lighting and shading variations associated with white-light-based image registration.
Collapse
Affiliation(s)
- Vasant Kearney
- Department of Radiation Oncology, University of California, San Francisco, CA, USA. Department of Bioengineering, University of Texas Arlington, Arlington, TX, USA
| | | | | | | | | |
Collapse
|
26
|
Landry G, Nijhuis R, Dedes G, Handrack J, Thieke C, Janssens G, Orban de Xivry J, Reiner M, Kamp F, Wilkens JJ, Paganelli C, Riboldi M, Baroni G, Ganswindt U, Belka C, Parodi K. Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation. Med Phys 2016; 42:1354-66. [PMID: 25735290 DOI: 10.1118/1.4908223] [Citation(s) in RCA: 103] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
PURPOSE Intensity modulated proton therapy (IMPT) of head and neck (H&N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone beam CT (CBCT) scanners are currently being offered by vendors, they may offer daily or weekly updates of patient anatomy. CBCT image quality may not be sufficient for accurate proton dose calculation and it is likely necessary to perform CBCT CT number correction. In this work, the authors investigated deformable image registration (DIR) of the planning CT (pCT) to the CBCT to generate a virtual CT (vCT) to be used for proton dose recalculation. METHODS Datasets of six H&N cancer patients undergoing photon intensity modulated radiation therapy were used in this study to validate the vCT approach. Each dataset contained a CBCT acquired within 3 days of a replanning CT (rpCT), in addition to a pCT. The pCT and rpCT were delineated by a physician. A Morphons algorithm was employed in this work to perform DIR of the pCT to CBCT following a rigid registration of the two images. The contours from the pCT were deformed using the vector field resulting from DIR to yield a contoured vCT. The DIR accuracy was evaluated with a scale invariant feature transform (SIFT) algorithm comparing automatically identified matching features between vCT and CBCT. The rpCT was used as reference for evaluation of the vCT. The vCT and rpCT CT numbers were converted to stopping power ratio and the water equivalent thickness (WET) was calculated. IMPT dose distributions from treatment plans optimized on the pCT were recalculated with a Monte Carlo algorithm on the rpCT and vCT for comparison in terms of gamma index, dose volume histogram (DVH) statistics as well as proton range. The DIR generated contours on the vCT were compared to physician-drawn contours on the rpCT. RESULTS The DIR accuracy was better than 1.4 mm according to the SIFT evaluation. The mean WET differences between vCT (pCT) and rpCT were below 1 mm (2.6 mm). The amount of voxels passing 3%/3 mm gamma criteria were above 95% for the vCT vs rpCT. When using the rpCT contour set to derive DVH statistics from dose distributions calculated on the rpCT and vCT the differences, expressed in terms of 30 fractions of 2 Gy, were within [-4, 2 Gy] for parotid glands (D(mean)), spinal cord (D(2%)), brainstem (D(2%)), and CTV (D(95%)). When using DIR generated contours for the vCT, those differences ranged within [-8, 11 Gy]. CONCLUSIONS In this work, the authors generated CBCT based stopping power distributions using DIR of the pCT to a CBCT scan. DIR accuracy was below 1.4 mm as evaluated by the SIFT algorithm. Dose distributions calculated on the vCT agreed well to those calculated on the rpCT when using gamma index evaluation as well as DVH statistics based on the same contours. The use of DIR generated contours introduced variability in DVH statistics.
Collapse
Affiliation(s)
- Guillaume Landry
- Department of Medical Physics, Ludwig-Maximilians-University, Munich D85748, Germany and Department of Radiation Oncology, Ludwig-Maximilians-University, Munich D81377, Germany
| | - Reinoud Nijhuis
- Department of Radiation Oncology, Ludwig-Maximilians-University, Munich D81377, Germany
| | - George Dedes
- Department of Medical Physics, Ludwig-Maximilians-University, Munich D85748, Germany
| | - Josefine Handrack
- Department of Medical Physics, Ludwig-Maximilians-University, Munich D85748, Germany
| | - Christian Thieke
- Department of Radiation Oncology, Ludwig-Maximilians-University, Munich D81377, Germany
| | - Guillaume Janssens
- ICTEAM, Université Catholique de Louvain, Louvain-La-Neuve B1348, Belgium
| | | | - Michael Reiner
- Department of Radiation Oncology, Ludwig-Maximilians-University, Munich D81377, Germany
| | - Florian Kamp
- Department of Radiation Oncology, Technische Universität München, Klinikum rechts der Isar, Munich D81675, Germany and Physik-Department, Technische Universität München, Garching D85748, Germany
| | - Jan J Wilkens
- Department of Radiation Oncology, Technische Universität München, Klinikum rechts der Isar, Munich D81675, Germany and Physik-Department, Technische Universität München, Garching D85748, Germany
| | - Chiara Paganelli
- Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano, Milan 20133, Italy
| | - Marco Riboldi
- Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano, Milan 20133, Italy
| | - Guido Baroni
- Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano, Milan 20133, Italy
| | - Ute Ganswindt
- Department of Radiation Oncology, Ludwig-Maximilians-University, Munich D81377, Germany
| | - Claus Belka
- Department of Radiation Oncology, Ludwig-Maximilians-University, Munich D81377, Germany
| | - Katia Parodi
- Department of Medical Physics, Ludwig-Maximilians-University, Munich D85748, Germany
| |
Collapse
|
27
|
Kurz C, Nijhuis R, Reiner M, Ganswindt U, Thieke C, Belka C, Parodi K, Landry G. Feasibility of automated proton therapy plan adaptation for head and neck tumors using cone beam CT images. Radiat Oncol 2016; 11:64. [PMID: 27129305 PMCID: PMC4851791 DOI: 10.1186/s13014-016-0641-7] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Accepted: 04/27/2016] [Indexed: 11/10/2022] Open
Abstract
Background Intensity modulated proton therapy (IMPT) of head and neck (H&N) tumors may benefit from plan adaptation to correct for the dose perturbations caused by weight loss and tumor volume changes observed in these patients. As cone beam CT (CBCT) is increasingly considered in proton therapy, it may be possible to use available CBCT images following intensity correction for plan adaptation. This is the first study exploring IMPT plan adaptation on CBCT images corrected and delineated by deformable image registration of the planning CT (pCT) to the CBCT, yielding a virtual CT (vCT). Methods A Morphons algorithm was used to deform the pCTs and corresponding delineations of 9 H&N cancer patients to a weekly CBCT acquired within ±3 days of a control replanning CT scan (rpCT). The IMPT treatment plans were adapted using the vCT and the adapted and original plans were recalculated on the rpCT for dose/volume parameter evaluation of the impact of adaptation. Results On the rpCT, the adapted plans were equivalent to the original plans in terms of target volumes D95 and V95, but showed a significant reduction of D2 in these volumes. OAR doses were mostly equivalent or reduced. In particular, the adapted plans did not reduce parotid gland Dmean, but the dose to the optical system. For three patients the spinal cord or brain stem received higher, though well below tolerance, maximum dose. Subsequent tightening of the treatment planning constraints for these OARs on new vCT-adapted plans did not degrade target coverage and yielded pCT equivalent plans on the vCT. Conclusions An offline automated procedure to generate an adapted IMPT plan on CBCT images was developed and investigated. When evaluating the adapted plan on a control rpCT we observed reduced D2 in target volumes as major improvement. OAR sparing was only partially improved by the procedure. Despite potential limitations in the accuracy of the vCT approach, an improved quality of the adapted plans could be achieved. Electronic supplementary material The online version of this article (doi:10.1186/s13014-016-0641-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Christopher Kurz
- Department of Radiation Oncology, LMU Munich, Munich, Germany.,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Reinoud Nijhuis
- Department of Radiation Oncology, LMU Munich, Munich, Germany
| | - Michael Reiner
- Department of Radiation Oncology, LMU Munich, Munich, Germany
| | - Ute Ganswindt
- Department of Radiation Oncology, LMU Munich, Munich, Germany
| | | | - Claus Belka
- Department of Radiation Oncology, LMU Munich, Munich, Germany
| | - Katia Parodi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, LMU Munich, Munich, Germany. .,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Munich, Germany.
| |
Collapse
|
28
|
Wang P, Yin L, Zhang Y, Kirk M, Song G, Ahn PH, Lin A, Gee J, Dolney D, Solberg TD, Maughan R, McDonough J, Teo BKK. Quantitative assessment of anatomical change using a virtual proton depth radiograph for adaptive head and neck proton therapy. J Appl Clin Med Phys 2016; 17:427-440. [PMID: 27074464 PMCID: PMC5875558 DOI: 10.1120/jacmp.v17i2.5819] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Revised: 11/25/2015] [Accepted: 11/17/2015] [Indexed: 11/23/2022] Open
Abstract
The aim of this work is to demonstrate the feasibility of using water-equivalent thickness (WET) and virtual proton depth radiographs (PDRs) of intensity corrected cone-beam computed tomography (CBCT) to detect anatomical change and patient setup error to trigger adaptive head and neck proton therapy. The planning CT (pCT) and linear accelerator (linac) equipped CBCTs acquired weekly during treatment of a head and neck patient were used in this study. Deformable image registration (DIR) was used to register each CBCT with the pCT and map Hounsfield units (HUs) from the planning CT (pCT) onto the daily CBCT. The deformed pCT is referred as the corrected CBCT (cCBCT). Two dimensional virtual lateral PDRs were generated using a ray-tracing technique to project the cumulative WET from a virtual source through the cCBCT and the pCT onto a virtual plane. The PDRs were used to identify anatomic regions with large variations in the proton range between the cCBCT and pCT using a threshold of 3 mm relative difference of WET and 3 mm search radius criteria. The relationship between PDR differences and dose distribution is established. Due to weight change and tumor response during treatment, large variations in WETs were observed in the relative PDRs which corresponded spatially with an increase in the number of failing points within the GTV, especially in the pharynx area. Failing points were also evident near the posterior neck due to setup variations. Differences in PDRs correlated spatially to differences in the distal dose distribution in the beam's eye view. Virtual PDRs generated from volumetric data, such as pCTs or CBCTs, are potentially a useful quantitative tool in proton therapy. PDRs and WET analysis may be used to detect anatomical change from baseline during treatment and trigger further analysis in adaptive proton therapy.
Collapse
|
29
|
Kurz C, Dedes G, Resch A, Reiner M, Ganswindt U, Nijhuis R, Thieke C, Belka C, Parodi K, Landry G. Comparing cone-beam CT intensity correction methods for dose recalculation in adaptive intensity-modulated photon and proton therapy for head and neck cancer. Acta Oncol 2015. [PMID: 26198654 DOI: 10.3109/0284186x.2015.1061206] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
BACKGROUND Adaptive intensity-modulated photon and proton radiotherapy (IMRT and IMPT) of head and neck (H&N) cancer requires frequent three-dimensional (3D) dose calculation. We compared two approaches for dose recalculation on the basis of intensity-corrected cone-beam (CB) x-ray computed tomography (CT) images. MATERIAL AND METHODS For nine H&N tumor patients, virtual CTs (vCT) were generated by deformable image registration of the planning CT (pCT) to the CBCT. The second intensity correction approach used population-based lookup tables for scaling CBCT intensities to the pCT HU range (CBCTLUT). IMRT and IMPT plans were generated with a commercial treatment planning system. Dose recalculations on vCT and CBCTLUT were analyzed using a (3%, 3 mm) gamma-index analysis and comparison of normal tissue and tumor dose/volume parameters. A replanning CT (rpCT) acquired within three days of the CBCT served as reference. Single field uniform dose (SFUD) proton plans were created and recalculated on vCT and CBCTLUT for proton range comparison. RESULTS Dose/volume parameters showed minor differences between rpCT, vCT and CBCTLUT in IMRT, but clinically relevant deviations between CBCTLUT and rpCT in the spinal cord for IMPT. Gamma-index pass-rates were found increased for vCT with respect to CBCTLUT in IMPT (by up to 21 percentage points) and IMRT (by up to 9 percentage points) for most cases. The SFUD-based proton range assessment showed improved agreement of vCT and rpCT, with 88-99% of the depth dose profiles in beam's eye view agreeing within 3 mm. For CBCTLUT, only 80-94% of the profiles fulfilled this criterion. CONCLUSION vCT and CBCTLUT are suitable options for dose recalculation in adaptive IMRT. In the scope of IMPT, the vCT approach is preferable.
Collapse
Affiliation(s)
- Christopher Kurz
- a Department of Radiation Oncology , Ludwig-Maximilians-University , Munich , Germany
- b Department of Medical Physics , Ludwig-Maximilians-University , Munich , Germany
| | - George Dedes
- b Department of Medical Physics , Ludwig-Maximilians-University , Munich , Germany
| | - Andreas Resch
- b Department of Medical Physics , Ludwig-Maximilians-University , Munich , Germany
| | - Michael Reiner
- a Department of Radiation Oncology , Ludwig-Maximilians-University , Munich , Germany
| | - Ute Ganswindt
- a Department of Radiation Oncology , Ludwig-Maximilians-University , Munich , Germany
| | - Reinoud Nijhuis
- a Department of Radiation Oncology , Ludwig-Maximilians-University , Munich , Germany
| | - Christian Thieke
- a Department of Radiation Oncology , Ludwig-Maximilians-University , Munich , Germany
| | - Claus Belka
- a Department of Radiation Oncology , Ludwig-Maximilians-University , Munich , Germany
| | - Katia Parodi
- b Department of Medical Physics , Ludwig-Maximilians-University , Munich , Germany
| | - Guillaume Landry
- a Department of Radiation Oncology , Ludwig-Maximilians-University , Munich , Germany
- b Department of Medical Physics , Ludwig-Maximilians-University , Munich , Germany
| |
Collapse
|
30
|
Moteabbed M, Sharp GC, Wang Y, Trofimov A, Efstathiou JA, Lu HM. Validation of a deformable image registration technique for cone beam CT-based dose verification. Med Phys 2015; 42:196-205. [PMID: 25563260 DOI: 10.1118/1.4903292] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
PURPOSE As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modulated radiotherapy (IMRT) dose based on multimodal deformable image registration (dir) for prostate treatments. METHODS A pelvic phantom was scanned with CT and cone-beam computed tomography (CBCT). Both images were digitally deformed using two realistic patient-based deformation fields. The original CT was then registered to the deformed CBCT resulting in a secondary deformed CT. The registration quality was assessed as the ability of the dir method to recover the artificially induced deformations. The primary and secondary deformed CT images as well as vector fields were compared to evaluate the efficacy of the registration method and it's suitability to be used for dose calculation. plastimatch, a free and open source software was used for deformable image registration. A B-spline algorithm with optimized parameters was used to achieve the best registration quality. Geometric image evaluation was performed through voxel-based Hounsfield unit (HU) and vector field comparison. For dosimetric evaluation, IMRT treatment plans were created and optimized on the original CT image and recomputed on the two warped images to be compared. The dose volume histograms were compared for the warped structures that were identical in both warped images. This procedure was repeated for the phantom with full, half full, and empty bladder. RESULTS The results indicated mean HU differences of up to 120 between registered and ground-truth deformed CT images. However, when the CBCT intensities were calibrated using a region of interest (ROI)-based calibration curve, these differences were reduced by up to 60%. Similarly, the mean differences in average vector field lengths decreased from 10.1 to 2.5 mm when CBCT was calibrated prior to registration. The results showed no dependence on the level of bladder filling. In comparison with the dose calculated on the primary deformed CT, differences in mean dose averaged over all organs were 0.2% and 3.9% for dose calculated on the secondary deformed CT with and without CBCT calibration, respectively, and 0.5% for dose calculated directly on the calibrated CBCT, for the full-bladder scenario. Gamma analysis for the distance to agreement of 2 mm and 2% of prescribed dose indicated a pass rate of 100% for both cases involving calibrated CBCT and on average 86% without CBCT calibration. CONCLUSIONS Using deformable registration on the planning CT images to evaluate the IMRT dose based on daily CBCTs was found feasible. The proposed method will provide an accurate dose distribution using planning CT and pretreatment CBCT data, avoiding the additional uncertainties introduced by CBCT inhomogeneity and artifacts. This is a necessary initial step toward future image-guided adaptive radiotherapy of the prostate.
Collapse
Affiliation(s)
- M Moteabbed
- Massachusetts General Hospital, Boston, Massachusetts 02114 and Harvard Medical School, Boston, Massachusetts 02115
| | - G C Sharp
- Massachusetts General Hospital, Boston, Massachusetts 02114 and Harvard Medical School, Boston, Massachusetts 02115
| | - Y Wang
- Massachusetts General Hospital, Boston, Massachusetts 02114 and Harvard Medical School, Boston, Massachusetts 02115
| | - A Trofimov
- Massachusetts General Hospital, Boston, Massachusetts 02114 and Harvard Medical School, Boston, Massachusetts 02115
| | - J A Efstathiou
- Massachusetts General Hospital, Boston, Massachusetts 02114 and Harvard Medical School, Boston, Massachusetts 02115
| | - H-M Lu
- Massachusetts General Hospital, Boston, Massachusetts 02114 and Harvard Medical School, Boston, Massachusetts 02115
| |
Collapse
|
31
|
Abstract
Combining adaptive and robust optimization in radiation therapy has the potential to mitigate the negative effects of both intrafraction and interfraction uncertainty over a fractionated treatment course. A previously developed adaptive and robust radiation therapy (ARRT) method for lung cancer was demonstrated to be effective when the sequence of breathing patterns was well-behaved. In this paper, we examine the applicability of the ARRT method to less well-behaved breathing patterns. We develop a novel method to generate sequences of probability mass functions that represent different types of drift in the underlying breathing pattern. Computational results derived from applying the ARRT method to these sequences demonstrate that the ARRT method is effective for a much broader class of breathing patterns than previously demonstrated.
Collapse
Affiliation(s)
- Philip Allen Mar
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto ON, M5S 3G8, Canada
| | | |
Collapse
|
32
|
Zhen X, Chen H, Yan H, Zhou L, Mell LK, Yashar CM, Jiang S, Jia X, Gu X, Cervino L. A segmentation and point-matching enhanced efficient deformable image registration method for dose accumulation between HDR CT images. Phys Med Biol 2015; 60:2981-3002. [DOI: 10.1088/0031-9155/60/7/2981] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|