Kim SH, Jeong JH, Ku Y, Lee SB, Shin D, Lim YK, Kim H, Kim CH. Range shift verification in spot scanning proton therapy using gamma electron vertex imaging. Med Phys 2024; 51:1985-1996. [PMID: 37722712 DOI: 10.1002/mp.16739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 08/28/2023] [Accepted: 08/29/2023] [Indexed: 09/20/2023] Open
Abstract
BACKGROUND In proton therapy, a highly steep distal dose penumbra can be utilized for dose conformity, given the Bragg peak characteristic of protons. However, the location of the Bragg peak in patients (i.e., the beam range) is very sensitive to range uncertainty. Even a small shift of beam range can produce a significant variation of delivered dose to tumor and normal tissues, thus degrading treatment quality and threatening patient safety. This range uncertainty issue, therefore, is one of the important aspects to be managed in proton therapy. PURPOSE For better management of range uncertainty, range verification has been widely studied, and prompt gamma imaging (PGI) is considered one of the promising methods in that effort. In this context, a PGI system named the gamma electron vertex imaging (GEVI) system was developed and recently upgraded for application to pencil-beam scanning (PBS) proton therapy. Here, we report the first experimental results using the therapeutic spot scanning proton beams. METHODS A homogeneous slab phantom and an anthropomorphic phantom were employed. Spherical and cubic planning target volumes (PTVs) were defined. Various range shift scenarios were introduced. Prompt gamma (PG) measurement was synchronized with beam irradiation. The measured PG distributions were aggregated to improve the PG statistics. The range shift was estimated based on the relative change of the centroid in the measured PG distribution. The estimated range shifts were analyzed by range shift mapping, confidence interval (CI) estimation, and statistical hypothesis testing. RESULTS The range shift mapping results showed an obvious measured range shift tendency following the true shift values. However, some fluctuations were found for spots that had still-low PG statistics after spot aggregation. The 99% CI distributions showed clearly distributed range shift measurement data. The overall accuracy and precision for all investigated scenarios were 0.36 and 0.20 mm, respectively. The results of one-sample t-tests confirmed that every shift scenario could be observed up to 1 mm of shift. The ANOVA results proved that the measured range shift data could be discriminated from one another, except for 16 (of 138) comparison cases having 1-2 mm shift differences. CONCLUSIONS This study demonstrated the feasibility of the GEVI system for measurement of range shift in spot scanning proton therapy. Our experimental results showed that the proton beam can be measured up to 1 mm of range shift with high accuracy and precision. We believe that the GEVI system is one of the most promising PGI systems for in vivo range verification. Further research for application to more various cases and patient treatments is planned.
Collapse
Affiliation(s)
- Sung Hun Kim
- Center for Proton Therapy, National Cancer Center, Gyeonggi-do, Republic of Korea
| | - Jong Hwi Jeong
- Center for Proton Therapy, National Cancer Center, Gyeonggi-do, Republic of Korea
| | - Youngmo Ku
- Department of Nuclear Engineering, Hanyang University, Seoul, Republic of Korea
| | - Se Byeong Lee
- Center for Proton Therapy, National Cancer Center, Gyeonggi-do, Republic of Korea
| | - Dongho Shin
- Center for Proton Therapy, National Cancer Center, Gyeonggi-do, Republic of Korea
| | - Young Kyung Lim
- Center for Proton Therapy, National Cancer Center, Gyeonggi-do, Republic of Korea
| | - Haksoo Kim
- Center for Proton Therapy, National Cancer Center, Gyeonggi-do, Republic of Korea
| | - Chan Hyeong Kim
- Department of Nuclear Engineering, Hanyang University, Seoul, Republic of Korea
| |
Collapse
|
2
|
Yamamoto S, Watabe H, Nakanishi K, Yabe T, Yamaguchi M, Kawachi N, Kamada K, Yoshikawa A, Miyake M, Tanaka KS, Kataoka J. A triple-imaging-modality system for simultaneous measurements of prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation. Phys Med Biol 2024; 69:055012. [PMID: 38385258 DOI: 10.1088/1361-6560/ad25c6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 02/01/2024] [Indexed: 02/23/2024]
Abstract
Objective. Prompt gamma photon, prompt x-ray, and induced positron imaging are possible methods for observing a proton beam's shape from outside the subject. However, since these three types of images have not been measured simultaneously nor compared using the same subject, their advantages and disadvantages remain unknown for imaging beam shapes in therapy. To clarify these points, we developed a triple-imaging-modality system to simultaneously measure prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation to a phantom.Approach. The developed triple-imaging-modality system consists of a gamma camera, an x-ray camera, and a dual-head positron emission tomography (PET) system. During 80 MeV proton beam irradiation to a polymethyl methacrylate (PMMA) phantom, imaging of prompt gamma photons was conducted by the developed gamma camera from one side of the phantom. Imaging of prompt x-rays was conducted by the developed x-ray camera from the other side. Induced positrons were measured by the developed dual-head PET system set on the upper and lower sides of the phantom.Main results. With the proposed triple-imaging-modality system, we could simultaneously image the prompt gamma photons and prompt x-rays during proton beam irradiation. Induced positron distributions could be measured after the irradiation by the PET system and the gamma camera. Among these imaging modalities, image quality was the best for the induced positrons measured by PET. The estimated ranges were actually similar to those imaged with prompt gamma photons, prompt x-rays and induced positrons measured by PET.Significance. The developed triple-imaging-modality system made possible to simultaneously measure the three different beam images. The system will contribute to increasing the data available for imaging in therapy and will contribute to better estimating the shapes or ranges of proton beam.
Collapse
Affiliation(s)
| | - Hiroshi Watabe
- Cyclotron and Radioisotope Center, Tohoku University, Japan
| | - Kohei Nakanishi
- Department of Integrated Health Science, Nagoya University Graduate School of Medicine, Japan
| | - Takuya Yabe
- Takasaki Institute for Advanced Quantum Science, Foundational Quantum Technology Research Directorate, National Institutes for Quantum Science and Technology (QST), Japan
| | - Mitsutaka Yamaguchi
- Takasaki Institute for Advanced Quantum Science, Foundational Quantum Technology Research Directorate, National Institutes for Quantum Science and Technology (QST), Japan
| | - Naoki Kawachi
- Takasaki Institute for Advanced Quantum Science, Foundational Quantum Technology Research Directorate, National Institutes for Quantum Science and Technology (QST), Japan
| | - Kei Kamada
- New Industry Creation Hatchery Center (NICHe), Tohoku University, Japan
| | - Akira Yoshikawa
- New Industry Creation Hatchery Center (NICHe), Tohoku University, Japan
| | | | - Kazuo S Tanaka
- Faculty of Science and Engineering, Waseda University, Japan
| | - Jun Kataoka
- Faculty of Science and Engineering, Waseda University, Japan
| |
Collapse
|
3
|
Kielly M, Caracciolo A, Chacon A, Vohradsky J, Di Vita D, Hamato A, Tashima H, Franklin DR, Yamaya T, Rosenfeld A, Carminati M, Fiorini C, Guatelli S, Safavi-Naeini M. First experimental demonstration of real-time neutron capture discrimination in helium and carbon ion therapy. Sci Rep 2024; 14:2601. [PMID: 38297114 PMCID: PMC10831067 DOI: 10.1038/s41598-024-52162-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 01/15/2024] [Indexed: 02/02/2024] Open
Abstract
This work provides the first experimental proof of an increased neutron capture photon signal following the introduction of boron to a PMMA phantom during helium and carbon ion therapies in Neutron Capture Enhanced Particle Therapy (NCEPT). NCEPT leverages [Formula: see text]B neutron capture, leading to the emission of detectable 478 keV photons. Experiments were performed at the Heavy Ion Medical Accelerator in Chiba, Japan, with two Poly(methyl methacrylate) (PMMA) targets, one bearing a boron insert. The BeNEdiCTE gamma-ray detector measured an increase in the 478 keV signal of 45 ± 7% and 26 ± 2% for carbon and helium ion irradiation, respectively. Our Geant4 Monte Carlo simulation model, developed to investigate photon origins, found less than 30% of detected photons originated from the insert, while boron in the detector's circuit boards contributed over 65%. Further, the model investigated detector sensitivity, establishing its capability to record a 10% increase in 478 keV photon detection at a target [Formula: see text]B concentration of 500 ppm using spectral windowing alone, and 25% when combined with temporal windowing. The linear response extended to concentrations up to 20,000 ppm. The increase in the signal in all evaluated cases confirm the potential of the proposed detector design for neutron capture quantification in NCEPT.
Collapse
Affiliation(s)
- Marissa Kielly
- Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, Australia
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Anita Caracciolo
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Milan, Italy
| | - Andrew Chacon
- Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, Australia
| | - James Vohradsky
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Davide Di Vita
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Milan, Italy
| | - Akram Hamato
- Imaging Physics Group, Department of Advanced Nuclear Medicine Sciences, National Institutes for Quantum Science and Technology (QST), Inage-ku, Chiba, Japan
| | - Hideaki Tashima
- Imaging Physics Group, Department of Advanced Nuclear Medicine Sciences, National Institutes for Quantum Science and Technology (QST), Inage-ku, Chiba, Japan
| | - Daniel R Franklin
- School of Electrical and Data Engineering, University of Technology Sydney, Sydney, Australia
| | - Taiga Yamaya
- Imaging Physics Group, Department of Advanced Nuclear Medicine Sciences, National Institutes for Quantum Science and Technology (QST), Inage-ku, Chiba, Japan
| | - Anatoly Rosenfeld
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Marco Carminati
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Milan, Italy
| | - Carlo Fiorini
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Milan, Italy
| | - Susanna Guatelli
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Mitra Safavi-Naeini
- Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, Australia.
| |
Collapse
|
4
|
Berthold J, Pietsch J, Piplack N, Khamfongkhruea C, Thiele J, Hölscher T, Janssens G, Smeets J, Traneus E, Löck S, Stützer K, Richter C. Detectability of Anatomical Changes With Prompt-Gamma Imaging: First Systematic Evaluation of Clinical Application During Prostate-Cancer Proton Therapy. Int J Radiat Oncol Biol Phys 2023; 117:718-729. [PMID: 37160193 DOI: 10.1016/j.ijrobp.2023.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 04/02/2023] [Accepted: 05/02/2023] [Indexed: 05/11/2023]
Abstract
PURPOSE The development of online-adaptive proton therapy (PT) is essential to overcome limitations encountered by day-to-day variations of the patient's anatomy. Range verification could play an essential role in an online feedback loop for the detection of treatment deviations such as anatomical changes. Here, we present the results of the first systematic patient study regarding the detectability of anatomical changes by a prompt-gamma imaging (PGI) slit-camera system. METHODS AND MATERIALS For 15 patients with prostate cancer, PGI measurements were performed during 105 fractions (201 fields) with in-room control computed tomography (CT)acquisitions. Field-wise doses on control CT scans were manually classified as whether showing relevant or non-relevant anatomical changes. This manual classification of the treatment fields was then used to establish an automatic field-wise ground truth based on spot-wise dosimetric range shifts, which were retrieved from integrated depth-dose (IDD) profiles. To determine the detection capability of anatomical changes with PGI, spot-wise PGI-based range shifts were initially compared with corresponding dosimetric IDD range shifts. As final endpoint, the agreement of a developed field-wise PGI classification model with the field-wise ground truth was determined. Therefore, the PGI model was optimized and tested for a subcohort of 131 and 70 treatment fields, respectively. RESULTS The correlation between PGI and IDD range shifts was high, ρpearson = 0.67 (p < 0.01). Field-wise binary PGI classification resulted in an area under the curve of 0.72 and 0.80 for training and test cohorts, respectively. The model detected relevant anatomical changes in the independent test cohort, with a sensitivity and specificity of 74% and 79%, respectively. CONCLUSIONS For the first time, evidence of the detection capability of anatomical changes in prostate-cancer PT from clinically acquired PGI data is shown. This emphasizes the benefit of PGI-based range verification and demonstrates its potential for online-adaptive PT.
Collapse
Affiliation(s)
- Jonathan Berthold
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.
| | - Julian Pietsch
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Nick Piplack
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Technische Universität Dresden, Faculty of Electrical and Computer Engineering, Dresden, Germany
| | - Chirasak Khamfongkhruea
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, Thailand
| | - Julia Thiele
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Tobias Hölscher
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | | | | | | | - Steffen Löck
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, Germany and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Kristin Stützer
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Christian Richter
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, Germany and German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
5
|
Yamamoto S, Yabe T, Akagi T, Yamaguchi M, Kawachi N, Kamada K, Yoshikawa A, Kataoka J. Prompt X-ray imaging during irradiation with spread-out Bragg peak (SOBP) beams of carbon ions. Phys Med 2023; 109:102592. [PMID: 37084677 DOI: 10.1016/j.ejmp.2023.102592] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 04/07/2023] [Accepted: 04/13/2023] [Indexed: 04/23/2023] Open
Abstract
Prompt secondary electron bremsstrahlung X-ray (prompt X-ray) imaging using a low-energy X-ray camera is a promising method for observing a beam shape from outside the subject. However, such imaging has so far been conducted only for pencil beams without a multi-leaf collimator (MLC). The use of spread-out Bragg peak (SOBP) with an MLC may increase the scattered prompt gamma photons and decrease the contrast of the images of prompt X-rays. Consequently, we performed prompt X-ray imaging of SOBP beams formed with an MLC. This imaging was carried out in list mode during irradiation of SOBP beams to a water phantom. An X-ray camera with a 1.5-mm diameter as well as 4-mm-diameter pinhole collimators was used for the imaging. List mode data were sorted to obtain the SOBP beam images as well as energy spectra and time count rate curves. Due to the high background counts from the scattered prompt gamma photons penetrating the tungsten shield of the X-ray camera, the SOBP beam shapes were difficult to observe with a 1.5-mm-diameter pinhole collimator. With the 4-mm-diameter pinhole collimators, images of SOBP beam shapes at clinical dose levels could be obtained with the X-ray camera. The use of a 4-mm-diameter pinhole collimator attached to the X-ray camera is effective for prompt X-ray imaging with high sensitivity and low background counts. This approach makes it possible to image SOBP beams with an MLC when the counts are low and the background levels are high.
Collapse
Affiliation(s)
| | - Takuya Yabe
- Takasaki Institute of Advanced Quantum Science, Foundational Quantum Technology Research Directorate, National Institutes for Quantum Science and Technology (QST), Japan
| | | | - Mitsutaka Yamaguchi
- Takasaki Institute of Advanced Quantum Science, Foundational Quantum Technology Research Directorate, National Institutes for Quantum Science and Technology (QST), Japan
| | - Naoki Kawachi
- Takasaki Institute of Advanced Quantum Science, Foundational Quantum Technology Research Directorate, National Institutes for Quantum Science and Technology (QST), Japan
| | - Kei Kamada
- New Industry Creation Hatchery Center (NICHe), Tohoku University, Japan
| | - Akira Yoshikawa
- New Industry Creation Hatchery Center (NICHe), Tohoku University, Japan
| | - Jun Kataoka
- Faculty of Science and Engineering, Waseda University, Japan
| |
Collapse
|
6
|
Bertschi S, Stützer K, Berthold J, Pietsch J, Smeets J, Janssens G, Richter C. Potential margin reduction in prostate cancer proton therapy with prompt gamma imaging for online treatment verification. Phys Imaging Radiat Oncol 2023; 26:100447. [PMID: 37287850 PMCID: PMC10242552 DOI: 10.1016/j.phro.2023.100447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 05/06/2023] [Accepted: 05/09/2023] [Indexed: 06/09/2023] Open
Abstract
The potential of proton therapy is currently limited due to large safety margins. We estimated the potential reduction of clinical margins when using prompt gamma imaging (PGI) for online treatment verification of prostate cancer. For two adaptive scenarios a potential reduction relative to clinical practice was evaluated. The use of a trolley-mounted PGI system for online treatment verification to trigger an adaptation reduced the current range margins from 7 mm to 3 mm. In a case example, the dose reduction due to reduced range margins was substantially larger compared to reduced setup margins when using pre-treatment volumetric imaging.
Collapse
Affiliation(s)
- Stefanie Bertschi
- OncoRay – National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden – Rossendorf, Fetscherstr. 74, PF41, 01307 Dresden, Germany
| | - Kristin Stützer
- OncoRay – National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden – Rossendorf, Fetscherstr. 74, PF41, 01307 Dresden, Germany
| | - Jonathan Berthold
- OncoRay – National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden – Rossendorf, Fetscherstr. 74, PF41, 01307 Dresden, Germany
- Helmholtz-Zentrum Dresden – Rossendorf, Institute of Radiooncology – OncoRay, Bautzner Landstr. 400, 01328 Dresden, Germany
| | - Julian Pietsch
- OncoRay – National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden – Rossendorf, Fetscherstr. 74, PF41, 01307 Dresden, Germany
- Helmholtz-Zentrum Dresden – Rossendorf, Institute of Radiooncology – OncoRay, Bautzner Landstr. 400, 01328 Dresden, Germany
| | - Julien Smeets
- Ion Beam Applications SA, Chemin du Cyclotron 3, 1348 Louvain-la-Neuve, Belgium
| | - Guillaume Janssens
- Ion Beam Applications SA, Chemin du Cyclotron 3, 1348 Louvain-la-Neuve, Belgium
| | - Christian Richter
- OncoRay – National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden – Rossendorf, Fetscherstr. 74, PF41, 01307 Dresden, Germany
- Helmholtz-Zentrum Dresden – Rossendorf, Institute of Radiooncology – OncoRay, Bautzner Landstr. 400, 01328 Dresden, Germany
- German Cancer Consortium (DKTK), Partner Site Dresden, and German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69192 Heidelberg, Germany
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstr. 74, PF 50, 01307 Dresden, Germany
| |
Collapse
|
7
|
Missaglia A, Bourkadi-Idrissi A, Casamichiela F, Mazzucconi D, Carminati M, Agosteo S, Fiorini C. Prompt-gamma fall-off estimation with C-ion irradiation at clinical energies, using a knife-edge slit camera: A Monte Carlo study. Phys Med 2023; 107:102554. [PMID: 36907030 DOI: 10.1016/j.ejmp.2023.102554] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Revised: 02/09/2023] [Accepted: 02/18/2023] [Indexed: 03/12/2023] Open
Abstract
PURPOSE In-vivo range verification has been a hot topic in particle therapy since two decades. Many efforts have been done for proton therapy, while fewer studies were conducted considering a beam of carbon ions. In the present work, a simulation study was performed to show whether it is possible to measure the prompt-gamma fall-off inside the high neutron background typical of carbon-ion irradiation, using a knife-edge slit camera. In addition to this, we wanted to estimate the uncertainty in retrieving the particle range in the case of a pencil beam of C-ions at clinically relevant energy of 150 MeVu. METHODS For these purposes, the Monte Carlo code FLUKA was adopted for simulations and three different analytical methods were implemented to get the accuracy in the range retrieval of the simulated set-up. RESULTS The analysis of simulation data has brought to the promising and desired precision of about 4 mm in the determination of the dose profile fall-off in case of a spill irradiation, for which all the three cited methods were coherent in their predictions. CONCLUSIONS The Prompt Gamma Imaging technique should be further studied as a tool to reduce range uncertainties affecting carbon ion radiation therapy.
Collapse
Affiliation(s)
- Andrea Missaglia
- Dipartimento di Elettronica, Informazione e Bioingegneria - Politecnico di Milano, Via Ponzio, 34/5, 20133, Milan, Italy.
| | - Aicha Bourkadi-Idrissi
- Dipartimento di Elettronica, Informazione e Bioingegneria - Politecnico di Milano, Via Ponzio, 34/5, 20133, Milan, Italy; INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy.
| | - Francesco Casamichiela
- Dipartimento di Energia - Politecnico di Milano, Via Lambruschini, 4, 20156, Milan, Italy.
| | - Davide Mazzucconi
- INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy; Dipartimento di Energia - Politecnico di Milano, Via Lambruschini, 4, 20156, Milan, Italy.
| | - Marco Carminati
- Dipartimento di Elettronica, Informazione e Bioingegneria - Politecnico di Milano, Via Ponzio, 34/5, 20133, Milan, Italy; INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy.
| | - Stefano Agosteo
- INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy; Dipartimento di Energia - Politecnico di Milano, Via Lambruschini, 4, 20156, Milan, Italy.
| | - Carlo Fiorini
- Dipartimento di Elettronica, Informazione e Bioingegneria - Politecnico di Milano, Via Ponzio, 34/5, 20133, Milan, Italy; INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy.
| |
Collapse
|
8
|
Malekzadeh E, Rajabi H, Tajik-Mansoury MA, Sabouri P, Fiorina E, Kalantari F. Design and performance evaluation of a slit-slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study. Med Phys 2023. [PMID: 36718592 DOI: 10.1002/mp.16259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 12/21/2022] [Accepted: 12/26/2022] [Indexed: 02/01/2023] Open
Abstract
PURPOSE We investigated the design of a prompt gamma camera for real-time dose delivery verification and the partial mitigation of range uncertainties. METHODS A slit slat (SS) camera was optimized using the trade-off between the signal-to-noise ratio and spatial resolution. Then, using the GATE Monte Carlo package, the camera performances were estimated by means of target shifts, beam position quantification, changing the camera distance from the beam, and air cavity inserting. A homogeneous PMMA phantom and the air gaps induced PMMA phantom were used. The air gaps ranged from 5 mm to 30 mm by 5 mm increments were positioned in the middle of the beam range. To reduce the simulation time, phase space scoring was used. The batch method with five realizations was used for stochastic error calculations. RESULTS The system's detection efficiency was 1.1 × 10 - 4 PGs Emitted PGs ( 1.8 × 10 - 5 $1.1 \times {10}^{-4}\frac{{\rm PGs}}{{\rm Emitted}\ {\rm PGs}}\ (1.8 \times {10}^{-5}$ PGs/proton) for a 10 × 20 cm2 detector (source-to-collimator distance = 15.0 cm). Axial and transaxial resolutions were 23 mm and 18 mm, respectively. The SS camera estimated the range as 69.0 ± 3.4 (relative stochastic error 1-sigma is 5%) and 67.6 ± 1.8 mm (2.6%) for the real range of 67.0 mm for 107 and 108 protons of 100 MeV, respectively. Considering 160 MeV, these values are 155.5 ± 3.1 (2%) and 152.2 ± 2.0 mm (1.3%) for the real range of 152.0 mm for 107 and 108 protons, respectively. Considering phantom shift, for a 100 MeV beam, the precision of the quantification (1-sigma) in the axial and lateral phantom shift estimation is 2.6 mm and 1 mm, respectively. Accordingly, the axial and lateral quantification precisions were 1.3 mm and 1 mm for a 160 MeV beam, respectively. Furthermore, the quantification of an air gap formulated as gap d e t = 0.98 × gap real ${{\rm gap}}_{det}=0.98 \times {{\rm gap}}_{{\rm real}}$ , where gap d e t ${{\rm gap}}_{det}$ and gapreal are the estimated and real air gap, respectively. The precision of the air gap quantification is 1.6 mm (1 sigma). Moreover, 2D PG images show the trajectory of the proton beam through the phantom. CONCLUSION The proposed slit-slat imaging systems can potentially provide a real-time, in-vivo, and non-invasive treatment monitoring method for proton therapy.
Collapse
Affiliation(s)
- Etesam Malekzadeh
- Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Hossein Rajabi
- Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Mohammad Ali Tajik-Mansoury
- Biomedical Engineering and Medical Physics Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Pouya Sabouri
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Elisa Fiorina
- National Institute of Nuclear Physics INFN, Section of Torino, Torino, Italy.,Clinical Department, Fondazione CNAO, Pavia, Italy
| | - Faraz Kalantari
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| |
Collapse
|
9
|
Giacomo SD, Utica G, Carminati M, Borghi G, Picciotto A, Fiorini C. Timing Performances of SDD as Photodetector Candidate for Proton Therapy Application. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022. [DOI: 10.1109/trpms.2021.3137668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- S. Di Giacomo
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - G. Utica
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - M. Carminati
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - G. Borghi
- Integrated Radiation and Image Sensors, Fondazione Bruno Kessler, Trento, Italy
| | - A. Picciotto
- Integrated Radiation and Image Sensors, Fondazione Bruno Kessler, Trento, Italy
| | - C. Fiorini
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| |
Collapse
|
10
|
Yabe T, Yamaguchi M, Liu CC, Toshito T, Kawachi N, Yamamoto S. Deep learning-based in vivo dose verification from proton-induced secondary-electron-bremsstrahlung images with various count level. Phys Med 2022; 99:130-139. [PMID: 35689979 DOI: 10.1016/j.ejmp.2022.05.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 05/23/2022] [Accepted: 05/25/2022] [Indexed: 12/22/2022] Open
Abstract
PURPOSE Proton-induced secondary-electron-bremsstrahlung (SEB) imaging is a promising method for estimating the ranges of particle beam. However, SEB images do not directly represent dose distributions of particle beams. In addition, the ranges estimated from measured images were deviated because of limited spatial resolutions of the developed x-ray camera as well as statistical noise in the images. To solve these problems, we proposed a method for predicting high-resolution dose images from SEB images with various count level using a deep learning (DL) approach for range and width verification. METHODS In this study, we adopted the double U-Net model, which is a previously proposed deep convolutional network model. The first U-Net model in the double U-Net model was used to denoise the SEB images with various count level. The first U-Net model for denoising was trained on 8000 pairs of SEB images with various count level and noise-free images which were created by a sophisticated in-house developed model function. The second U-Net model for dose prediction was trained using 8000 pairs of denoised SEB images from the first U-Net model and high-resolution dose images generated by Monte Carlo simulation. RESULTS For both simulation and measurement data, the trained DL model could successfully predict high-resolution dose images which showed a clear Bragg peak and no statistical noise. The difference of the range and width was less than 2.1 mm, even from the SEB images measured with a decrease in the number of irradiated protons to less than 11% of 3.2 × 1011 protons. CONCLUSIONS High-resolution dose images from measured and simulated SEB images were successfully predicted by using the trained DL model for protons. Our proposed DL model was feasible to predict dose images accurately even with smaller number of irradiated protons.
Collapse
Affiliation(s)
- Takuya Yabe
- Department of Integrated Health Science, Nagoya University Graduate School of Medicine, Aichi, Japan; Department of Medical Technology, Nagoya University Hospital, Aichi, Japan.
| | - Mitsutaka Yamaguchi
- Takasaki Advanced Radiation Research Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum Science and Technology (QST), Gunma, Japan
| | - Chih-Chieh Liu
- Department of Biomedical Engineering, University of California, Davis, USA
| | - Toshiyuki Toshito
- Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City University West Medical Center, Aichi, Japan
| | - Naoki Kawachi
- Takasaki Advanced Radiation Research Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum Science and Technology (QST), Gunma, Japan
| | - Seiichi Yamamoto
- Department of Integrated Health Science, Nagoya University Graduate School of Medicine, Aichi, Japan; Faculty of Science and Engineering, Waseda University, Tokyo, Japan
| |
Collapse
|
11
|
Ku Y, Jung J, Kim CH. New Algorithm to Estimate Proton Beam Range for Multi-slit Prompt-gamma Camera. NUCLEAR ENGINEERING AND TECHNOLOGY 2022. [DOI: 10.1016/j.net.2022.04.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
12
|
Polf JC, Barajas CA, Peterson SW, Mackin DS, Beddar S, Ren L, Gobbert MK. Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy. FRONTIERS IN PHYSICS 2022; 10:838273. [PMID: 36119562 PMCID: PMC9481064 DOI: 10.3389/fphy.2022.838273] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We studied the application of a deep, fully connected Neural Network (NN) to process prompt gamma (PG) data measured by a Compton camera (CC) during the delivery of clinical proton radiotherapy beams. The network identifies 1) recorded "bad" PG events arising from background noise during the measurement, and 2) the correct ordering of PG interactions in the CC to help improve the fidelity of "good" data used for image reconstruction. PG emission from a tissue-equivalent target during irradiation with a 150 MeV proton beam delivered at clinical dose rates was measured with a prototype CC. Images were reconstructed from both the raw measured data and the measured data that was further processed with a neural network (NN) trained to identify "good" and "bad" PG events and predict the ordering of individual interactions within the good PG events. We determine if NN processing of the CC data could improve the reconstructed PG images to a level in which they could provide clinically useful information about the in vivo range and range shifts of the proton beams delivered at full clinical dose rates. Results showed that a deep, fully connected NN improved the achievable contrast to noise ratio (CNR) in our images by more than a factor of 8x. This allowed the path, range, and lateral width of the clinical proton beam within a tissue equivalent target to easily be identified from the PG images, even at the highest dose rates of a 150 MeV proton beam used for clinical treatments. On average, shifts in the beam range as small as 3 mm could be identified. However, when limited by the amount of PG data measured with our prototype CC during the delivery of a single proton pencil beam (~1 × 109 protons), the uncertainty in the reconstructed PG images limited the identification of range shift to ~5 mm. Substantial improvements in CC images were obtained during clinical beam delivery through NN pre-processing of the measured PG data. We believe this shows the potential of NNs to help improve and push CC-based PG imaging toward eventual clinical application for proton RT treatment delivery verification.
Collapse
Affiliation(s)
- Jerimy C. Polf
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, United States
| | - Carlos A. Barajas
- Department of Mathematics and Statistics, University of Maryland Baltimore County, Baltimore, MD, United States
| | | | - Dennis S. Mackin
- Department of Medical Physics, University of Texas M.D. Anderson Cancer Center, Houston, TX, United States
| | - Sam Beddar
- Department of Medical Physics, University of Texas M.D. Anderson Cancer Center, Houston, TX, United States
| | - Lei Ren
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, United States
| | - Matthias K. Gobbert
- Department of Mathematics and Statistics, University of Maryland Baltimore County, Baltimore, MD, United States
| |
Collapse
|
13
|
Pennazio F, Ferrero V, D'Onghia G, Garbolino S, Fiorina E, Marti Villarreal OA, Mas Milian F, Monaco V, Monti V, Patera A, Werner J, Wheadon R, Rafecas M. Proton therapy monitoring: spatiotemporal emission reconstruction with prompt gamma timing and implementation with PET detectors. Phys Med Biol 2022; 67. [PMID: 35193131 DOI: 10.1088/1361-6560/ac5765] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 02/22/2022] [Indexed: 12/17/2022]
Abstract
Objective. In this study we introduce spatiotemporal emission reconstruction prompt gamma timing (SER-PGT), a new method to directly reconstruct the prompt photon emission in the space and time domains inside the patient in proton therapy.Approach. SER-PGT is based on the numerical optimisation of a multidimensional likelihood function, followed by a post-processing of the results. The current approach relies on a specific implementation of the maximum-likelihood expectation maximisation algorithm. The robustness of the method is guaranteed by the complete absence of any information about the target composition in the algorithm.Main results. Accurate Monte Carlo simulations indicate a range resolution of about 0.5 cm (standard deviation) when considering 107primary protons impinging on an homogeneous phantom. Preliminary results on an anthropomorphic phantom are also reported.Significance. By showing the feasibility for the reconstruction of the primary particle range using PET detectors, this study provides significant basis for the development of an hybrid in-beam PET and prompt photon device.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Felix Mas Milian
- INFN, Torino, Italy.,Universitá degli Studi di Torino, Torino, Italy.,Universidade Estadual de Santa Cruz, Ilheus, Brazil
| | - Vincenzo Monaco
- INFN, Torino, Italy.,Universitá degli Studi di Torino, Torino, Italy
| | | | | | | | | | | |
Collapse
|
14
|
Polf JC, Maggi P, Panthi R, Peterson S, Mackin D, Beddar S. The effects of Compton camera data acquisition and readout timing on PG imaging for proton range verification. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022; 6:366-373. [PMID: 36092269 PMCID: PMC9457195 DOI: 10.1109/trpms.2021.3057341] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The purpose of this study was to determine how the characteristics of the data acquisition (DAQ) electronics of a Compton camera (CC) affect the quality of the recorded prompt gamma (PG) interaction data and the reconstructed images, during clinical proton beam delivery. We used the Monte-Carlo-plus-Detector-Effect (MCDE) model to simulate the delivery of a 150 MeV clinical proton pencil beam to a tissue-equivalent plastic phantom. With the MCDE model we analyzed how the recorded PG interaction data changed as two characteristics of the DAQ electronics of a CC were changed: (1) the number of data readout channels; and (2) the active charge collection, readout, and reset time. As the proton beam dose rate increased, the number of recorded PG single-, double-, and triple-scatter events decreased by a factor of 60× for the current DAQ configuration of the CC. However, as the DAQ readout channels were increased and the readout/reset timing decreased, the number of recorded events decreased by <5× at the highest clinical dose rate. The increased number of readout channels and reduced readout/reset timing also resulted in higher quality recorded data. That is, a higher percentage of the recorded double- and triple-scatters were "true" events (caused by a single incident gamma) and not "false" events (caused by multiple incident gammas). The increase in the number and the quality of recorded data allowed higher quality PG images to be reconstructed even at the highest clinical dose rates.
Collapse
Affiliation(s)
- Jerimy C. Polf
- University of Maryland School of Medicine, Baltimore, Maryland 21201
| | - Paul Maggi
- University of Maryland School of Medicine, Baltimore, Maryland 21201, USA
| | - Rajesh Panthi
- University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030, USA
| | | | - Dennis Mackin
- University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030
| | - Sam Beddar
- University of Texas M.D. Anderson Cancer Center, Houston, TX 77030
| |
Collapse
|
15
|
Towards machine learning aided real-time range imaging in proton therapy. Sci Rep 2022; 12:2735. [PMID: 35177663 PMCID: PMC8854574 DOI: 10.1038/s41598-022-06126-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 01/20/2022] [Indexed: 11/08/2022] Open
Abstract
Compton imaging represents a promising technique for range verification in proton therapy treatments. In this work, we report on the advantageous aspects of the i-TED detector for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been specifically designed for neutron-capture nuclear physics experiments, which are characterized by [Formula: see text]-ray energies spanning up to 5-6 MeV, rather low [Formula: see text]-ray emission yields and very intense neutron induced [Formula: see text]-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high [Formula: see text]-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl[Formula: see text] crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr[Formula: see text]. Its high time-resolution (CRT [Formula: see text] 500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED Compton module features two detection planes of very large LaCl[Formula: see text] monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1 MeV [Formula: see text]-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10[Formula: see text] protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy [Formula: see text]-rays is compensated by means of machine-learning based algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.
Collapse
|
16
|
Paganetti H, Botas P, Sharp GC, Winey B. Adaptive proton therapy. Phys Med Biol 2021; 66:10.1088/1361-6560/ac344f. [PMID: 34710858 PMCID: PMC8628198 DOI: 10.1088/1361-6560/ac344f] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 10/28/2021] [Indexed: 12/25/2022]
Abstract
Radiation therapy treatments are typically planned based on a single image set, assuming that the patient's anatomy and its position relative to the delivery system remains constant during the course of treatment. Similarly, the prescription dose assumes constant biological dose-response over the treatment course. However, variations can and do occur on multiple time scales. For treatment sites with significant intra-fractional motion, geometric changes happen over seconds or minutes, while biological considerations change over days or weeks. At an intermediate timescale, geometric changes occur between daily treatment fractions. Adaptive radiation therapy is applied to consider changes in patient anatomy during the course of fractionated treatment delivery. While traditionally adaptation has been done off-line with replanning based on new CT images, online treatment adaptation based on on-board imaging has gained momentum in recent years due to advanced imaging techniques combined with treatment delivery systems. Adaptation is particularly important in proton therapy where small changes in patient anatomy can lead to significant dose perturbations due to the dose conformality and finite range of proton beams. This review summarizes the current state-of-the-art of on-line adaptive proton therapy and identifies areas requiring further research.
Collapse
Affiliation(s)
- Harald Paganetti
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| | - Pablo Botas
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
- Foundation 29 of February, Pozuelo de Alarcón, Madrid, Spain
| | - Gregory C Sharp
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| | - Brian Winey
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
17
|
Berthold J, Khamfongkhruea C, Petzoldt J, Thiele J, Hölscher T, Wohlfahrt P, Peters N, Jost A, Hofmann C, Janssens G, Smeets J, Richter C. First-In-Human Validation of CT-Based Proton Range Prediction Using Prompt Gamma Imaging in Prostate Cancer Treatments. Int J Radiat Oncol Biol Phys 2021; 111:1033-1043. [PMID: 34229052 DOI: 10.1016/j.ijrobp.2021.06.036] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 05/20/2021] [Accepted: 06/23/2021] [Indexed: 12/11/2022]
Abstract
PURPOSE Uncertainty in computed tomography (CT)-based range prediction substantially impairs the accuracy of proton therapy. Direct determination of the stopping-power ratio (SPR) from dual-energy CT (DECT) has been proposed (DirectSPR), and initial validation studies in phantoms and biological tissues have proven a high accuracy. However, a thorough validation of range prediction in patients has not yet been achieved by any means. Here, we present the first systematic validation of CT-based proton range prediction in patients using prompt gamma imaging (PGI). METHODS AND MATERIALS A PGI slit camera system with improved positioning accuracy, using a floor-based docking station, was used. Its overall uncertainty for range prediction validation was determined experimentally with both x-ray and beam measurements. The accuracy of range prediction in patients was determined from clinical PGI measurements during hypofractionated treatment of 5 patients with prostate cancer - in total 30 fractions with in-room control-CTs. For each pencil-beam-scanning spot, the range shift was obtained by comparing the PGI measurement to a control-CT-based PGI simulation. Three different SPR prediction approaches were applied in simulations: a standard CT-number-to-SPR conversion (Hounsfield look-up table [HLUT]), an adapted HLUT (DECT optimized), and DirectSPR. The spot-wise weighted mean range shift from all spots served as a measure for the accuracy of the respective range prediction approach. RESULTS A mean range prediction accuracy of 0.0% ± 0.5%, 0.3% ± 0.4%, and 1.8% ± 0.4% was obtained for DirectSPR, adapted HLUT, and standard HLUT, respectively. The overall validation uncertainty of the second-generation PGI slit camera is about 1 mm (2σ) for all approaches, which is smaller than the range prediction uncertainty for deep-seated tumors. CONCLUSIONS For the first time, range prediction accuracy was assessed in clinical routine using PGI range verification in prostate cancer treatments. Both DECT-derived range prediction approaches agree well with the measured proton range from PGI verification, whereas the standard HLUT approach differs relevantly. These results endorse the recent reduction of clinical safety margins in DirectSPR-based treatment planning in our institution.
Collapse
Affiliation(s)
- Jonathan Berthold
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.
| | - Chirasak Khamfongkhruea
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Faculty of Medicine and Public Health, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok, Thailand
| | | | - Julia Thiele
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Tobias Hölscher
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Patrick Wohlfahrt
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Nils Peters
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Angelina Jost
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Beuth Hochschule für Technik, Berlin, Germany
| | | | | | | | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, Germany and German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
18
|
Jacquet M, Marcatili S, Gallin-Martel ML, Bouly JL, Boursier Y, Dauvergne D, Dupont M, Gallin-Martel L, Hérault J, Létang JM, Manéval D, Morel C, Muraz JF, Testa É. A time-of-flight-based reconstruction for real-time prompt-gamma imaging in proton therapy. Phys Med Biol 2021; 66. [PMID: 34020438 DOI: 10.1088/1361-6560/ac03ca] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 05/21/2021] [Indexed: 11/12/2022]
Abstract
We propose a novel prompt-gamma (PG) imaging modality for real-time monitoring in proton therapy: PG time imaging (PGTI). By measuring the time-of-flight (TOF) between a beam monitor and a PG detector, our goal is to reconstruct the PG vertex distribution in 3D. In this paper, a dedicated, non-iterative reconstruction strategy is proposed (PGTI reconstruction). Here, it was resolved under a 1D approximation to measure a proton range shift along the beam direction. In order to show the potential of PGTI in the transverse plane, a second method, based on the calculation of the centre of gravity (COG) of the TIARA pixel detectors' counts was also explored. The feasibility of PGTI was evaluated in two different scenarios. Under the assumption of a 100 ps (rms) time resolution (achievable in single proton regime), MC simulations showed that a millimetric proton range shift is detectable at 2σwith 108incident protons in simplified simulation settings. With the same proton statistics, a potential 2 mm sensitivity (at 2σwith 108incident protons) to beam displacements in the transverse plane was found using the COG method. This level of precision would allow to act in real-time if the treatment does not conform to the treatment plan. A worst case scenario of a 1 ns (rms) TOF resolution was also considered to demonstrate that a degraded timing information can be compensated by increasing the acquisition statistics: in this case, a 2 mm range shift would be detectable at 2σwith 109incident protons. By showing the feasibility of a time-based algorithm for the reconstruction of the PG vertex distribution for a simplified anatomy, this work poses a theoretical basis for the future development of a PG imaging detector based on the measurement of particle TOF.
Collapse
Affiliation(s)
- Maxime Jacquet
- Université Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3 UMR 5821, F-38000 Grenoble, France
| | - Sara Marcatili
- Université Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3 UMR 5821, F-38000 Grenoble, France
| | | | - Jean-Luc Bouly
- Université Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3 UMR 5821, F-38000 Grenoble, France
| | | | - Denis Dauvergne
- Université Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3 UMR 5821, F-38000 Grenoble, France
| | | | - Laurent Gallin-Martel
- Université Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3 UMR 5821, F-38000 Grenoble, France
| | | | - Jean-Michel Létang
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69373 Lyon, France
| | | | | | - Jean-François Muraz
- Université Grenoble Alpes, CNRS, Grenoble INP, LPSC-IN2P3 UMR 5821, F-38000 Grenoble, France
| | - Étienne Testa
- Univ. Lyon, Univ. Claude Bernard Lyon 1, CNRS/IN2P3, IP2I Lyon, F-69622, Villeurbanne, France
| |
Collapse
|
19
|
Livingstone J, Dauvergne D, Etxebeste A, Fontana M, Gallin-Martel ML, Huisman B, Létang JM, Marcatili S, Sarrut D, Testa É. Influence of sub-nanosecond time of flight resolution for online range verification in proton therapy using the line-cone reconstruction in Compton imaging. Phys Med Biol 2021; 66. [PMID: 34020434 DOI: 10.1088/1361-6560/ac03cb] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 05/21/2021] [Indexed: 11/11/2022]
Abstract
Online ion range monitoring in hadron therapy can be performed via detection of secondary radiation, such as promptγ-rays, emitted during treatment. The promptγemission profile is correlated with the ion depth-dose profile and can be reconstructed via Compton imaging. The line-cone reconstruction, using the intersection between the primary beam trajectory and the cone reconstructed via a Compton camera, requires negligible computation time compared to iterative algorithms. A recent report hypothesised that time of flight (TOF) based discrimination could improve the precision of theγfall-off position (FOP) measured via line-cone reconstruction, where TOF comprises both the proton transit time from the phantom entrance untilγemission, and the flight time of theγ-ray to the detector. The aim of this study was to implement such a method and investigate the influence of temporal resolution on the precision of the FOP. Monte Carlo simulations of a 160 MeV proton beam incident on a homogeneous PMMA phantom were performed using GATE. The Compton camera consisted of a silicon-based scatterer and CeBr3scintillator absorber. The temporal resolution of the detection system (absorber + beam trigger) was varied between 0.1 and 1.3 ns rms and a TOF-based discrimination method applied to eliminate unlikely solution(s) from the line-cone reconstruction. The FOP was obtained for varying temporal resolutions and its precision obtained from its shift across 100 independentγemission profiles compared to a high statistics reference profile. The optimal temporal resolution for the given camera geometry and 108primary protons was 0.2 ns where a precision of 2.30 ± 0.15 mm (1σ) on the FOP was found. This precision is comparable to current state-of-the-art Compton imaging using iterative reconstruction methods or 1D imaging with mechanically collimated devices, and satisfies the requirement of being smaller than the clinical safety margins.
Collapse
Affiliation(s)
- Jayde Livingstone
- Univ Lyon, Université Claude Bernard Lyon 1, CNRS/IN2P3, Institut de Physique des 2 Infinis, F-69622 Villeurbanne, France.,Université Grenoble Alpes, CNRS/IN2P3, Laboratoire de Physique Subatomique et de Cosmologie, F-38026 Grenoble, France
| | - Denis Dauvergne
- Université Grenoble Alpes, CNRS/IN2P3, Laboratoire de Physique Subatomique et de Cosmologie, F-38026 Grenoble, France
| | - Ane Etxebeste
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69373 Lyon, France
| | - Mattia Fontana
- Univ Lyon, Université Claude Bernard Lyon 1, CNRS/IN2P3, Institut de Physique des 2 Infinis, F-69622 Villeurbanne, France
| | - Marie-Laure Gallin-Martel
- Université Grenoble Alpes, CNRS/IN2P3, Laboratoire de Physique Subatomique et de Cosmologie, F-38026 Grenoble, France
| | - Brent Huisman
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69373 Lyon, France
| | - Jean Michel Létang
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69373 Lyon, France
| | - Sara Marcatili
- Université Grenoble Alpes, CNRS/IN2P3, Laboratoire de Physique Subatomique et de Cosmologie, F-38026 Grenoble, France
| | - David Sarrut
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69373 Lyon, France
| | - Étienne Testa
- Université Grenoble Alpes, CNRS/IN2P3, Laboratoire de Physique Subatomique et de Cosmologie, F-38026 Grenoble, France
| |
Collapse
|
20
|
Tian L, Huang Z, Janssens G, Landry G, Dedes G, Kamp F, Belka C, Pinto M, Parodi K. Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning. Phys Med Biol 2021; 66:055005. [PMID: 33171445 DOI: 10.1088/1361-6560/abc939] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Prompt gamma (PG) imaging is widely investigated as one of the most promising methods for proton range verification in proton therapy. The performance of this technique is affected by several factors like tissue heterogeneity, number of protons in the considered pencil beam and the detection device. Our previous work proposed a new treatment planning concept which boosts the number of protons of a few PG monitoring-friendly pencil beams (PBs), selected on the basis of two proposed indicators quantifying the conformity between the dose and PG at the emission level, above the desired detectability threshold. To further explore this method at the detection level, in this work we investigated the response of a knife-edge slit PG camera which was deployed in the first clinical application of PG to proton therapy monitoring. The REGistration Graphical User Interface (REGGUI) is employed to simulate the PG emission, PG detection as well as the corresponding dose distribution. As the PG signal detected by this kind of PG camera is sensitive to the relative position of the camera and PG signal falloff, we optimized our PB selection method for this camera by introducing a new camera position indicator identifying whether the expected falloff of the PG signal is centered in the field of view of the camera or not. Our camera-adapted PB selection method is investigated using computed tomography (CT) scans at two different treatment time points of a head and neck, and a prostate cancer patient under scenarios considering different statistics level. The results show that a precision of 0.8 mm for PG falloff identification can be achieved when a PB has more than 2 × 108 primary protons. Except for one case due to unpredictable and comparably large anatomical changes, the PG signals of most of the PBs recommended by all our indicators are observed to be reliable for proton range verification with deviations between the inter-fractional shift of proton range (as deduced from the PB dose distribution) and the detected PG signal within 2.0 mm. In contrast, a shift difference up to 9.6 mm has been observed for the rejected PBs. The magnitude of the proton range shift due to the inter-fractional anatomical changes is observed to be up to 23 mm. The proposed indicators are shown to be valuable for identifying and recommending reliable PBs to create new PG monitoring-friendly TPs. Comparison between our PB boosting method and the alternative PB aggregation, which combines the signal of nearby PBs to reach the desired counting statistics, is also discussed.
Collapse
Affiliation(s)
- Liheng Tian
- Ludwig-Maximilians-Universität München, Department of Medical Physics, Munich, Germany. These authors have contributed to this work equally
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Jeyasugiththan J, Nieto Camero J, Symons J, Jones P, Buffler A, Geduld D, Peterson SW. Measuring prompt gamma-ray emissions from elements found in tissue during passive-beam proton therapy. Biomed Phys Eng Express 2021; 7. [PMID: 33540400 DOI: 10.1088/2057-1976/abe33d] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 02/04/2021] [Indexed: 11/12/2022]
Abstract
Prompt gamma detection during proton radiotherapy for range verification purposes will need to operate in both active and passive treatment beam environments. This paper describes prompt gamma measurements using a high resolution 2″ × 2″ LaBr3detector for a 200 MeV clinical passive-scatter proton beam. These measurements examine the most likely discrete prompt gamma rays emitted from tissue by detecting gammas produced in water, Perspex, carbon and liquid-nitrogen targets. Measurements were carried out at several positions around the depth corresponding to the location of the Bragg peak for water and Perspex targets in order to investigate prompt gamma emission as a function of depth along the beam path. This work also focused on validating the Geant4 Monte Carlo model of the passive-scatter proton beam line and LaBr3detector by making a direct comparison between the simulated and experimental results. The initial prompt gamma measurements were overwhelmed by the high amount of scattered radiation when measuring at isocenter, shifting the target further downstream from the final collimator significantly reduced the background radiation. Prompt gamma peaks were then clearly identified for the water, Perspex and graphite targets. The developed Geant4 Monte Carlo model was able to replicate the measured prompt gamma ray energy spectra, including production for important photopeaks to within 10%, except for the 4.44 MeV peak from the water target, which had more than a 50% overestimation of the number of produced prompt gamma rays. The prompt gamma measurements at various depths correlated well with the proton dose deposition; the 4.44 and 6.13 MeV photopeak profiles peaked within 1 cm of the Bragg peak and the R50%value for the 3-7 MeV energy range predicted the proton range within 8 mm.
Collapse
Affiliation(s)
| | | | - Julyan Symons
- Department of Nuclear Medicine, iThemba LABS, Faure, 7131, South Africa
| | - Pete Jones
- Department of Nuclear Medicine, iThemba LABS, Faure, 7131, South Africa
| | - Andy Buffler
- Department of Physics, RW James, University Avenue, University of Cape Town, Rondebosch 7701, Cape Town, South Africa
| | - Dieter Geduld
- Department of Physics, RW James, University Avenue, University of Cape Town, Rondebosch 7701, Cape Town, South Africa
| | - Stephen W Peterson
- Department of Physics, RW James, University Avenue, University of Cape Town, Rondebosch 7701, Cape Town, South Africa
| |
Collapse
|
22
|
Ros García A, Barrio J, Etxebeste A, García López J, Jiménez-Ramos MC, Lacasta C, Muñoz E, Oliver JF, Roser J, Llosá G. MACACO II test-beam with high energy photons. ACTA ACUST UNITED AC 2020; 65:245027. [DOI: 10.1088/1361-6560/abc5cd] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
23
|
Ozoemelam I, van der Graaf E, van Goethem MJ, Kapusta M, Zhang N, Brandenburg S, Dendooven P. Feasibility of quasi-prompt PET-based range verification in proton therapy. Phys Med Biol 2020; 65:245013. [PMID: 32650323 DOI: 10.1088/1361-6560/aba504] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Compared to photon therapy, proton therapy allows a better conformation of the dose to the tumor volume with reduced radiation dose to co-irradiated tissues. In vivo verification techniques including positron emission tomography (PET) have been proposed as quality assurance tools to mitigate proton range uncertainties. Detection of differences between planned and actual dose delivery on a short timescale provides a fast trigger for corrective actions. Conventional PET-based imaging of 15O (T1/2 = 2 min) and 11C (T1/2 = 20 min) distributions precludes such immediate feedback. We here present a demonstration of near real-time range verification by means of PET imaging of 12N (T1/2 = 11 ms). PMMA and graphite targets were irradiated with a 150 MeV proton pencil beam consisting of a series of pulses of 10 ms beam-on and 90 ms beam-off. Two modules of a modified Siemens Biograph mCT PET scanner (21 × 21 cm2 each), installed 25 cm apart, were used to image the beam-induced PET activity during the beam-off periods. The modifications enable the detectors to be switched off during the beam-on periods. 12N images were reconstructed using planar tomography. Using a 1D projection of the 2D reconstructed 12N image, the activity range was obtained from a fit of the activity profile with a sigmoid function. Range shifts due to modified target configurations were assessed for multiples of the clinically relevant 108 protons per pulse (approximately equal to the highest intensity spots in the pencil beam scanning delivery of a dose of 1 Gy over a cubic 1 l volume). The standard deviation of the activity range, determined from 30 datasets obtained from three irradiations on PMMA and graphite targets, was found to be 2.5 and 2.6 mm (1σ) with 108 protons per pulse and 0.9 and 0.8 mm (1σ) with 109 protons per pulse. Analytical extrapolation of the results from this study shows that using a scanner with a solid angle coverage of 57%, with optimized detector switching and spot delivery times much smaller than the 12N half-life, an activity range measurement precision of 2.0 mm (1σ) and 1.3 mm (1σ) within 50 ms into an irradiation with 4 × 107 and 108 protons per pencil beam spot can be potentially realized. Aggregated imaging of neighboring spots or, if possible, increasing the number of protons for a few probe beam spots will enable the realization of higher precision range measurement.
Collapse
Affiliation(s)
- Ikechi Ozoemelam
- KVI-Center for Advanced Radiation Technology, University of Groningen, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
24
|
Panthi R, Maggi P, Peterson S, Mackin D, Polf J, Beddar S. Secondary Particle Interactions in a Compton Camera Designed for in vivo Range Verification of Proton Therapy. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020; 5:383-391. [PMID: 34056151 DOI: 10.1109/trpms.2020.3030166] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The purpose of this study was to determine the types, proportions, and energies of secondary particle interactions in a Compton camera (CC) during the delivery of clinical proton beams. The delivery of clinical proton pencil beams ranging from 70 to 200 MeV incident on a water phantom was simulated using Geant4 software (version 10.4). The simulation included a CC similar to the configuration of a Polaris J3 CC designed to image prompt gammas (PGs) emitted during proton beam irradiation for the purpose of in vivo range verification. The interaction positions and energies of secondary particles in each CC detector module were scored. For a 150-MeV proton beam, a total of 156,688(575) secondary particles per 108 protons, primarily composed of gamma rays (46.31%), neutrons (41.37%), and electrons (8.88%), were found to reach the camera modules, and 79.37% of these particles interacted with the modules. Strategies for using CCs for proton range verification should include methods of reducing the large neutron backgrounds and low-energy non-PG radiation. The proportions of interaction types by module from this study may provide information useful for background suppression.
Collapse
Affiliation(s)
- Rajesh Panthi
- The University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030, USA
| | - Paul Maggi
- University of Maryland School of Medicine, Baltimore, Maryland 21201, USA
| | | | - Dennis Mackin
- The University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030
| | - Jerimy Polf
- University of Maryland School of Medicine, Baltimore, Maryland 21201
| | - Sam Beddar
- University of Texas M. D. Anderson Cancer Center, Houston, TX 77030
| |
Collapse
|
25
|
Xie Y, Petzoldt J, Janssens G, O'Grady F, Yin L, Bentefour EH, Smeets J, Prieels D, Lustig RA, Lin A, Teo BK. Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region. Br J Radiol 2020; 93:20190619. [PMID: 32960655 DOI: 10.1259/bjr.20190619] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES Prompt gamma (PG) imaging has previously been demonstrated for use in proton range verification of a brain treatment with a homogeneous target region. In this study, the feasibility of PG imaging to detect anatomic change within a heterogeneous region is presented. METHODS A prompt gamma camera recorded several fractions of a patient treatment to the base of skull. An evaluation CT revealed a decrease in sinus cavity filling during the treatment course. Comparison of PG profiles between measurement and simulation was performed to investigate range variations between planned and measured pencil beam spot positions. RESULTS For one field, an average over range of 3 mm due to the anatomic change could be detected for a subset of spots traversing the sinus cavity region. The two other fields appeared less impacted by the change but predicted range variations could not be detected. These results were partially consistent with the simulations of the evaluation CT. CONCLUSION We report the first clinical application of PG imaging that detected some of the expected small regional proton range deviations due to anatomic change in a heterogeneous region. However, several limitations exist with the technology that may limit its sensitivity to detect range deviations in heterogeneous regions. ADVANCES IN KNOWLEDGE We report on the first detection of range variations due to anatomic change in a heterogeneous region using PGI. The results confirm the feasibility of using PG-based range verification in highly heterogeneous target regions to identify deviations from the treatment plan.
Collapse
Affiliation(s)
- Yunhe Xie
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.,Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| | | | | | - Fionnbarr O'Grady
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Lingshu Yin
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Julien Smeets
- Ion Beam Applications S.A., Louvain-la-Neuve, Belgium
| | | | - Robert A Lustig
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Alexander Lin
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Boon-Keng Teo
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
26
|
Khamfongkhruea C, Berthold J, Janssens G, Petzoldt J, Smeets J, Pausch G, Richter C. Classification of the source of treatment deviation in proton therapy using prompt-gamma imaging information. Med Phys 2020; 47:5102-5111. [PMID: 32678913 DOI: 10.1002/mp.14393] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 06/30/2020] [Accepted: 07/03/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Prompt-gamma imaging (PGI)-based range verification has been successfully implemented in clinical proton therapy recently and its sensitivity to detect treatment deviations is currently investigated. The cause of treatment deviations can be multiple - for example, computed tomography (CT)-based range prediction, patient setup, and anatomical changes. Hence, it would be beneficial, if PGI-based verification would not only detect a treatment deviation but would also be able to directly identify its most probable source. Here, we propose a heuristically derived decision tree approach to automatically classify the sources of range deviation in proton pencil-beam scanning (PBS) treatments of head and neck tumors based on range information obtained with a PGI slit camera. MATERIALS AND METHODS The decision tree model was iteratively generated on a training dataset of different anatomical complexities, for an anthropomorphic head phantom and patient CT data (planning and control CTs) from five patients. Different range prediction errors, setup changes and relevant and nonrelevant anatomical changes were introduced or derived from control CTs, summing up to a total of 98 training scenarios. Independent validation was performed for another 98 scenarios, derived solely from patient CT data of another seven patients. PBS head and neck treatment plans were generated for the nominal scenario. For all PBS spots in the investigated field, PGI profiles were simulated using a dedicated analytical model of the slit camera for the nominal as well as the different error scenarios. From comparison of PGI profiles for nominal and error scenarios, a spot-wise range shift after spot aggregation with a kernel of 7 mm sigma was determined for each error scenario. The heuristic approach includes a prefiltering of the most suitable PBS spots for PGI treatment verification. From the validation, the accuracy, sensitivity, and specificity of the model were determined. RESULTS A five-step consecutive filter was developed to preselect PBS spots. On average, 25% of spots (1044 spots) remained as input for the classification model. The derived heuristic decision tree model is based on five parameters: The coefficient of determination (R2 ), the slope and intercept of the linear regression between PGI-derived range shifts and the respectively predicted proton ranges for the investigated PBS spots, as well as the average and standard deviation of the PGI-derived shifts. With this approach, 94 of 98 error scenarios could be classified correctly in validation (accuracy of 96%). A sensitivity and specificity of 100% and 86% were reached. CONCLUSIONS In this simulation study it was demonstrated that the source of a treatment deviation can be identified from simulated noiseless PGI information in head and neck tumor treatments with high sensitivity and specificity. The application, refinement, and evaluation of the approach on measured PGI data will be the next step to show the clinical feasibility of PGI-based error source classification.
Collapse
Affiliation(s)
- Chirasak Khamfongkhruea
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Faculty of Medicine and Public Health, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok, Thailand
| | - Jonathan Berthold
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany
| | | | | | | | - Guntram Pausch
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,German Cancer Consortium (DKTK), partner site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
27
|
Yamamoto S, Yamaguchi M, Akagi T, Kitano M, Kawachi N. Sensitivity improvement of YAP(Ce) cameras for imaging of secondary electron bremsstrahlung x-rays emitted during carbon-ion irradiation: problem and solution. Phys Med Biol 2020; 65:105008. [PMID: 32101809 DOI: 10.1088/1361-6560/ab7a6e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Low-energy x-ray imaging of secondary electron bremsstrahlung x-rays emitted during carbon-ion irradiation is a promising method for range estimation and could be used for imaging with almost clinical dose levels of carbon ion. However, the number of counts in images with clinical dose levels is relatively small, making it difficult to obtain precise range estimations. Since improving the sensitivity of the x-ray camera may solve this issue, we developed two new types of x-ray cameras. One uses a 1 mm thick, 40 mm × 40 mm cerium-doped yttrium aluminum perovskite (YA1O3: YAP(Ce)) scintillator plate combined with a 2 inch square flat panel photomultiplier tube (FP-PMT) contained in a 2 cm thick tungsten shield with a pinhole collimator positioned 50 mm from the scintillator; the other uses a 0.5 mm thick, 20 mm × 20 mm YAP(Ce) scintillator plate combined with a 1 inch square position sensitive photomultiplier tube (PSPMT) contained in the same tungsten shield with a pinhole collimator, but with the scintillator positioned closer (30 mm) to the pinhole collimator to obtain a similar field of view. For both cameras, we used a wider angle (∼55°) pinhole collimator to measure the phantom closer to improve sensitivity. Although the 40 mm × 40 mm YAP(Ce) camera had high system spatial resolution, the background count fractions were high and produced a high count area at the center of the images due to the pulse pileup of the signals. With the 20 mm × 20 mm YAP(Ce) camera, we obtained x-ray images with low background counts without a high count area at the image center. By smoothing the measured images, we were able to estimate the ranges even for clinical dose levels. We therefore confirmed that one of our newly developed YAP(Ce) cameras had high sensitivity and is promising for the imaging of secondary electron bremsstrahlung x-rays during irradiation of carbon ions in clinical conditions.
Collapse
Affiliation(s)
- Seiichi Yamamoto
- Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya 461-8673, Japan
| | | | | | | | | |
Collapse
|
28
|
Yamaguchi M, Liu CC, Huang HM, Yabe T, Akagi T, Kawachi N, Yamamoto S. Dose image prediction for range and width verifications from carbon ion-induced secondary electron bremsstrahlung x-rays using deep learning workflow. Med Phys 2020; 47:3520-3532. [PMID: 32335924 DOI: 10.1002/mp.14205] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 03/12/2020] [Accepted: 04/17/2020] [Indexed: 12/22/2022] Open
Abstract
PURPOSE Imaging of the secondary electron bremsstrahlung (SEB) x rays emitted during particle-ion irradiation is a promising method for beam range estimation. However, the SEB x-ray images are not directly correlated to the dose images. In addition, limited spatial resolution of the x-ray camera and low-count situation may impede correctly estimating the beam range and width in SEB x-ray images. To overcome these limitations of the SEB x-ray images measured by the x-ray camera, a deep learning (DL) approach was proposed in this work to predict the dose images for estimating the range and width of the carbon ion beam on the measured SEB x-ray images. METHODS To prepare enough data for the DL training efficiently, 10,000 simulated SEB x-ray and dose image pairs were generated by our in-house developed model function for different carbon ion beam energies and doses. The proposed DL neural network consists of two U-nets for SEB x ray to dose image conversion and super resolution. After the network being trained with these simulated x-ray and dose image pairs, the dose images were predicted from simulated and measured SEB x-ray testing images for performance evaluation. RESULTS For the 500 simulated testing images, the average mean squared error (MSE) was 2.5 × 10-5 and average structural similarity index (SSIM) was 0.997 while the error of both beam range and width was within 1 mm FWHM. For the three measured SEB x-ray images, the MSE was no worse than 5.5 × 10-3 and SSIM was no worse than 0.980 while the error of the beam range and width was 2 mm and 5 mm FWHM, respectively. CONCLUSIONS We have demonstrated the advantages of predicting dose images from not only simulated data but also measured data using our deep learning approach.
Collapse
Affiliation(s)
- Mitsutaka Yamaguchi
- Takasaki Advanced Radiation Research Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science (QST), Takasaki, Japan
| | - Chih-Chieh Liu
- Department of Biomedical Engineering, University of California, Davis, CA, USA
| | - Hsuan-Ming Huang
- Institute of Medical Device and Imaging, College of Medicine, National Taiwan University, Taipei City, Taiwan
| | - Takuya Yabe
- Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | | | - Naoki Kawachi
- Takasaki Advanced Radiation Research Institute, Quantum Beam Science Research Directorate, National Institutes for Quantum and Radiological Science (QST), Takasaki, Japan
| | - Seiichi Yamamoto
- Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
29
|
Hueso-González F, Bortfeld T. Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: a Theoretical Study. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020; 4:170-183. [PMID: 32258856 PMCID: PMC7111431 DOI: 10.1109/trpms.2019.2930362] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Range uncertainties in proton therapy hamper treatment precision. Prompt gamma-rays were suggested 16 years ago for real-time range verification, and have already shown promising results in clinical studies with collimated cameras. Simultaneously, alternative imaging concepts without collimation are investigated to reduce the footprint and price of current prototypes. In this manuscript, a compact range verification method is presented. It monitors prompt gamma-rays with a single scintillation detector positioned coaxially to the beam and behind the patient. Thanks to the solid angle effect, proton range deviations can be derived from changes in the number of gamma-rays detected per proton, provided that the number of incident protons is well known. A theoretical background is formulated and the requirements for a future proof-of-principle experiment are identified. The potential benefits and disadvantages of the method are discussed, and the prospects and potential obstacles for its use during patient treatments are assessed. The final milestone is to monitor proton range differences in clinical cases with a statistical precision of 1 mm, a material cost of 25000 USD and a weight below 10 kg. This technique could facilitate the widespread application of in vivo range verification in proton therapy and eventually the improvement of treatment quality.
Collapse
Affiliation(s)
- F Hueso-González
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States of America
| | - T Bortfeld
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States of America
| |
Collapse
|
30
|
Yamaguchi M, Nagao Y, Kawachi N. A Simulation Study on Estimation of Bragg-Peak Shifts via Machine Learning Using Proton-Beam Images Obtained by Measurement of Secondary Electron Bremsstrahlung. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020. [DOI: 10.1109/trpms.2019.2928016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
31
|
Zhang H, Fan P, Wang S, Xia Y, Xu T, Wei Q, Lu W, Wu Z, Liu Y, Ma T. Design and Performance Evaluation of a BGO + SiPM Detector for High-Energy Prompt Gamma Imaging in Proton Therapy Monitoring. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020. [DOI: 10.1109/trpms.2020.2972594] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
32
|
Panaino CMV, Mackay RI, Kirkby KJ, Taylor MJ. A New Method to Reconstruct in 3D the Emission Position of the Prompt Gamma Rays following Proton Beam Irradiation. Sci Rep 2019; 9:18820. [PMID: 31827167 PMCID: PMC6906450 DOI: 10.1038/s41598-019-55349-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Accepted: 11/26/2019] [Indexed: 01/18/2023] Open
Abstract
A new technique for range verification in proton beam therapy has been developed. It is based on the detection of the prompt γ rays that are emitted naturally during the delivery of the treatment. A spectrometer comprising 16 LaBr3(Ce) detectors in a symmetrical configuration is employed to record the prompt γ rays emitted along the proton path. An algorithm has been developed that takes as inputs the LaBr3(Ce) detector signals and reconstructs the maximum γ-ray intensity peak position, in full 3 dimensions. For a spectrometer radius of 8 cm, which could accommodate a paediatric head and neck case, the prompt γ-ray origin can be determined from the width of the detected peak with a σ of 4.17 mm for a 180 MeV proton beam impinging a water phantom. For spectrometer radii of 15 and 25 cm to accommodate larger volumes this value increases to 5.65 and 6.36 mm. For a 8 cm radius, with a 5 and 10 mm undershoot, the σ is 4.31 and 5.47 mm. These uncertainties are comparable to the range uncertainties incorporated in treatment planning. This work represents the first step towards a new accurate, real-time, 3D range verification device for spot-scanning proton beam therapy.
Collapse
Affiliation(s)
- Costanza M V Panaino
- Division of Cancer Sciences, University of Manchester, M13 9PL, Manchester, UK. .,The Christie NHS Foundation Trust, M20 4BX, Manchester, UK.
| | - Ranald I Mackay
- Division of Cancer Sciences, University of Manchester, M13 9PL, Manchester, UK.,The Christie NHS Foundation Trust, M20 4BX, Manchester, UK
| | - Karen J Kirkby
- Division of Cancer Sciences, University of Manchester, M13 9PL, Manchester, UK.,The Christie NHS Foundation Trust, M20 4BX, Manchester, UK
| | - Michael J Taylor
- Division of Cancer Sciences, University of Manchester, M13 9PL, Manchester, UK.,The Christie NHS Foundation Trust, M20 4BX, Manchester, UK
| |
Collapse
|
33
|
Ozoemelam I, van der Graaf E, Brandenburg S, Dendooven P. The production of positron emitters with millisecond half-life during helium beam radiotherapy. Phys Med Biol 2019; 64:235012. [PMID: 31658450 DOI: 10.1088/1361-6560/ab51c3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Therapy with helium ions is currently receiving significantly increasing interest because helium ions have a sharper penumbra than protons and undergo less fragmentation than carbon ions and thus require less complicated dose calculations. For any ion of interest in hadron therapy, the accuracy of dose delivery is limited by range uncertainties. This has led to efforts by several groups to develop in vivo verification techniques, including positron emission tomography (PET), for monitoring of the dose delivery. Beam-on PET monitoring during proton therapy through the detection of short-lived positron emitters such as 12N (T 1/2 = 11 ms), an emerging PET technique, provides an attractive option given the achievable range accuracy, minimal susceptibility to biological washout and provision of near prompt feedback. Extension of this approach to helium ions requires information on the production yield of relevant short-lived positron emitters. This study presents the first measurements of the production of short-lived positron emitters in water, graphite, calcium and phosphorus targets irradiated with 59 MeV/u 3He and 50 MeV/u 4He beams. For these targets, the most produced short-lived nuclides are 13O/12N (T 1/2 = 8.6/11 ms) on water, 13O/12N on graphite, 43Ti/41Sc/42Sc (T 1/2 = 509-680 ms) on calcium, 28P (T 1/2 = 268 ms) on phosphorus. A translation of the results from elemental targets to PMMA and representative tissues such as adipose tissue, muscle, compact and cortical bone, shows the dominance of 13O/12N in at least the first 20 s of an irradiation with 4He and somewhat longer with 3He. As the production of 13O/12N in a 3He irradiation is 3-4 times higher than in a 4He irradiation, from a statistical point of view, range verification using 13O/12N PET imaging will be about 2 times more precise for a 3He irradiation compared to a 4He irradiation.
Collapse
|
34
|
Park JH, Kim SH, Ku Y, Kim CH, Lee HR, Jeong JH, Lee SB, Shin DH. Multi-slit prompt-gamma camera for locating of distal dose falloff in proton therapy. NUCLEAR ENGINEERING AND TECHNOLOGY 2019. [DOI: 10.1016/j.net.2019.03.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
35
|
Yamamoto S, Yamaguchi M, Akagi T, Sasano M, Kawachi N. Development of a YAP(Ce) camera for the imaging of secondary electron bremsstrahlung x-ray emitted during carbon-ion irradiation toward the use of clinical conditions. Phys Med Biol 2019; 64:135019. [PMID: 31071695 DOI: 10.1088/1361-6560/ab2072] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Low-energy x-ray imaging of the secondary electron bremsstrahlung (SEB) x-ray emitted during carbon-ion irradiation is a promising method for range estimation. However, it remains unclear whether the method can be used for imaging with the clinical dose levels of carbon-ion and whether the bremsstrahlung x-ray can be detected from the deeper part of the body. To clarify these points, we developed a new high resolution low-energy x-ray camera and conducted imaging of the SEB x-ray during the irradiation of carbon-ions of different energies and intensities. Imaging was also tried with an x-ray camera using a human-head-sized, 17 cm diameter cylindrical phantom. To develop a high resolution imaging detector for a low-energy x-ray, we used a 20 × 20 × 0.5 mm thick cerium-doped yttrium aluminum perovskite, YA1O3 (YAP(Ce)) scintillator plate, which was optically coupled to a 25 mm square high quantum efficiency (HQE) type position sensitive photomultiplier tube (PSPMT). The imaging detector was encased in a 2 cm thick tungsten container and a pinhole collimator was attached to its camera head. After evaluating the camera's performance, SEB x-ray imaging was tried during irradiation of the carbon-ion and compared the results with a Monte Carlo simulation. We imaged the beam tracks by the SEB x-ray in real-time during irradiation of the carbon-ion and imaging and range estimation were possible even with near clinical dose level of 7.5 × 108 particles of carbon-ion. Clear images of a SEB x-ray were also obtained for a 17 cm diameter cylindrical phantom. The measured images were good agreement with the Monte Carlo simulation. We confirmed that our developed YAP(Ce) camera is promising for imaging SEB x-rays during irradiation of carbon-ions even near clinical conditions.
Collapse
Affiliation(s)
- Seiichi Yamamoto
- Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya, 461-8673, Japan. These two authors equally contributed to this paper. Author to whom any correspondence should be addressed
| | | | | | | | | |
Collapse
|
36
|
Dendooven P, Buitenhuis HJT, Diblen F, Heeres PN, Biegun AK, Fiedler F, van Goethem MJ, van der Graaf ER, Brandenburg S. Corrigendum: Short-lived positron emitters in beam-on PET imaging during proton therapy (2015 Phys. Med. Biol. 60 8923). Phys Med Biol 2019. [DOI: 10.1088/1361-6560/ab23d7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
37
|
Zarifi M, Guatelli S, Qi Y, Bolst D, Prokopovich D, Rosenfeld A. Characterization of prompt gamma ray emission for in vivo range verification in particle therapy: A simulation study. Phys Med 2019; 62:20-32. [DOI: 10.1016/j.ejmp.2019.04.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 04/15/2019] [Accepted: 04/24/2019] [Indexed: 11/27/2022] Open
|
38
|
Werner T, Berthold J, Hueso-González F, Koegler T, Petzoldt J, Roemer K, Richter C, Rinscheid A, Straessner A, Enghardt W, Pausch G. Processing of prompt gamma-ray timing data for proton range measurements at a clinical beam delivery. ACTA ACUST UNITED AC 2019; 64:105023. [DOI: 10.1088/1361-6560/ab176d] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
39
|
Comparison of knife-edge and multi-slit camera for proton beam range verification by Monte Carlo simulation. NUCLEAR ENGINEERING AND TECHNOLOGY 2019. [DOI: 10.1016/j.net.2018.10.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
40
|
Parodi K, Polf JC. In vivo range verification in particle therapy. Med Phys 2018; 45:e1036-e1050. [PMID: 30421803 DOI: 10.1002/mp.12960] [Citation(s) in RCA: 88] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 04/11/2018] [Accepted: 05/01/2018] [Indexed: 12/19/2022] Open
Abstract
Exploitation of the full potential offered by ion beams in clinical practice is still hampered by several sources of treatment uncertainties, particularly related to the limitations of our ability to locate the position of the Bragg peak in the tumor. To this end, several efforts are ongoing to improve the characterization of patient position, anatomy, and tissue stopping power properties prior to treatment as well as to enable in vivo verification of the actual dose delivery, or at least beam range, during or shortly after treatment. This contribution critically reviews methods under development or clinical testing for verification of ion therapy, based on pretreatment range and tissue probing as well as the detection of secondary emissions or physiological changes during and after treatment, trying to disentangle approaches of general applicability from those more specific to certain anatomical locations. Moreover, it discusses future directions, which could benefit from an integration of multiple modalities or address novel exploitation of the measurable signals for biologically adapted therapy.
Collapse
Affiliation(s)
- Katia Parodi
- Department of Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. Munich, 85748, Germany
| | - Jerimy C Polf
- Deparment of Radiation Oncology, Maryland Proton Treatment Center, University of Maryland School of Medicine, 22 South Greene St., Baltimore, MD, 21201, USA
| |
Collapse
|
41
|
Nenoff L, Priegnitz M, Janssens G, Petzoldt J, Wohlfahrt P, Trezza A, Smeets J, Pausch G, Richter C. Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification. Radiother Oncol 2017; 125:534-540. [DOI: 10.1016/j.radonc.2017.10.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 09/30/2017] [Accepted: 10/10/2017] [Indexed: 10/18/2022]
|
42
|
Aldawood S, Thirolf P, Miani A, Böhmer M, Dedes G, Gernhäuser R, Lang C, Liprandi S, Maier L, Marinšek T, Mayerhofer M, Schaart D, Lozano IV, Parodi K. Development of a Compton camera for prompt-gamma medical imaging. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.01.024] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
43
|
Ando K, Yamaguchi M, Yamamoto S, Toshito T, Kawachi N. Development of a low-energy x-ray camera for the imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation for range estimation. Phys Med Biol 2017; 62:5006-5020. [PMID: 28531093 DOI: 10.1088/1361-6560/aa7166] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation is a possible method for measurement of the proton beam distribution in phantom. However, it is not clear that the method is used for range estimation of protons. For this purpose, we developed a low-energy x-ray camera and conducted imaging of the bremsstrahlung x-ray produced during irradiation of proton beams. We used a 20 mm × 20 mm × 1 mm finely grooved GAGG scintillator that was optically coupled to a one-inch square high quantum efficiency (HQE)-type position-sensitive photomultiplier tube to form an imaging detector. The imaging detector was encased in a 2 cm-thick tungsten container, and a pinhole collimator was attached to its camera head. After performance of the camera was evaluated, secondary electron bremsstrahlung x-ray imaging was conducted during irradiation of the proton beams for three different proton energies, and the results were compared with Monte Carlo simulation as well as calculated value. The system spatial resolution and sensitivity of the developed x-ray camera with 1.5 mm-diameter pinhole collimator were estimated to be 32 mm FWHM and 5.2 × 10-7 for ~35 keV x-ray photons at 100 cm from the collimator surface, respectively. We could image the proton beam tracks by measuring the secondary electron bremsstrahlung x-ray during irradiation of the proton beams, and the ranges for different proton energies could be estimated from the images. The measured ranges from the images were well matched with the Monte Carlo simulation, and slightly smaller than the calculated values. We confirmed that the imaging of the secondary electron bremsstrahlung x-ray emitted during proton irradiation with the developed x-ray camera has the potential to be a new tool for proton range estimations.
Collapse
Affiliation(s)
- Koki Ando
- Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | | | | | | | | |
Collapse
|
44
|
Xie Y, Bentefour EH, Janssens G, Smeets J, Vander Stappen F, Hotoiu L, Yin L, Dolney D, Avery S, O'Grady F, Prieels D, McDonough J, Solberg TD, Lustig RA, Lin A, Teo BKK. Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy. Int J Radiat Oncol Biol Phys 2017; 99:210-218. [PMID: 28816148 DOI: 10.1016/j.ijrobp.2017.04.027] [Citation(s) in RCA: 94] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2017] [Revised: 03/22/2017] [Accepted: 04/21/2017] [Indexed: 10/19/2022]
Abstract
PURPOSE To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. METHODS AND MATERIALS A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. RESULTS In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were -0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and -0.4 ± 0.9 mm for the vertex field. CONCLUSIONS This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.
Collapse
Affiliation(s)
- Yunhe Xie
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - Guillaume Janssens
- Advanced Technology Group, Ion Beam Applications SA, Louvain-la-Neuve, Belgium
| | - Julien Smeets
- Advanced Technology Group, Ion Beam Applications SA, Louvain-la-Neuve, Belgium
| | | | - Lucian Hotoiu
- Advanced Technology Group, Ion Beam Applications SA, Louvain-la-Neuve, Belgium
| | - Lingshu Yin
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Derek Dolney
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Stephen Avery
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Fionnbarr O'Grady
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Damien Prieels
- Advanced Technology Group, Ion Beam Applications SA, Louvain-la-Neuve, Belgium
| | - James McDonough
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Timothy D Solberg
- Department of Radiation Oncology, University of California, San Francisco, California
| | - Robert A Lustig
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Alexander Lin
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Boon-Keng K Teo
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania.
| |
Collapse
|
45
|
Buitenhuis HJT, Diblen F, Brzezinski KW, Brandenburg S, Dendooven P. Beam-on imaging of short-lived positron emitters during proton therapy. Phys Med Biol 2017; 62:4654-4672. [PMID: 28379155 DOI: 10.1088/1361-6560/aa6b8c] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In vivo dose delivery verification in proton therapy can be performed by positron emission tomography (PET) of the positron-emitting nuclei produced by the proton beam in the patient. A PET scanner installed in the treatment position of a proton therapy facility that takes data with the beam on will see very short-lived nuclides as well as longer-lived nuclides. The most important short-lived nuclide for proton therapy is 12N (Dendooven et al 2015 Phys. Med. Biol. 60 8923-47), which has a half-life of 11 ms. The results of a proof-of-principle experiment of beam-on PET imaging of short-lived 12N nuclei are presented. The Philips Digital Photon Counting Module TEK PET system was used, which is based on LYSO scintillators mounted on digital SiPM photosensors. A 90 MeV proton beam from the cyclotron at KVI-CART was used to investigate the energy and time spectra of PET coincidences during beam-on. Events coinciding with proton bunches, such as prompt gamma rays, were removed from the data via an anti-coincidence filter with the cyclotron RF. The resulting energy spectrum allowed good identification of the 511 keV PET counts during beam-on. A method was developed to subtract the long-lived background from the 12N image by introducing a beam-off period into the cyclotron beam time structure. We measured 2D images and 1D profiles of the 12N distribution. A range shift of 5 mm was measured as 6 ± 3 mm using the 12N profile. A larger, more efficient, PET system with a higher data throughput capability will allow beam-on 12N PET imaging of single spots in the distal layer of an irradiation with an increased signal-to-background ratio and thus better accuracy. A simulation shows that a large dual panel scanner, which images a single spot directly after it is delivered, can measure a 5 mm range shift with millimeter accuracy: 5.5 ± 1.1 mm for 1 × 108 protons and 5.2 ± 0.5 mm for 5 × 108 protons. This makes fast and accurate feedback on the dose delivery during treatment possible.
Collapse
Affiliation(s)
- H J T Buitenhuis
- KVI-Center for Advanced Radiation Technology, University of Groningen, Zernikelaan 25, 9747 AA, Groningen, Netherlands
| | | | | | | | | |
Collapse
|
46
|
Hueso-Gonzalez F, Pausch G, Petzoldt J, Romer KE, Enghardt W. Prompt Gamma Rays Detected With a BGO Block Compton Camera Reveal Range Deviations of Therapeutic Proton Beams. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2017. [DOI: 10.1109/tns.2016.2622162] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
47
|
Zarifi M, Guatelli S, Bolst D, Hutton B, Rosenfeld A, Qi Y. Characterization of prompt gamma-ray emission with respect to the Bragg peak for proton beam range verification: A Monte Carlo study. Phys Med 2017; 33:197-206. [DOI: 10.1016/j.ejmp.2016.12.011] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 10/06/2016] [Accepted: 12/11/2016] [Indexed: 11/26/2022] Open
|
48
|
Piliero MA, Pennazio F, Bisogni MG, Camarlinghi N, Cerello PG, Del Guerra A, Ferrero V, Fiorina E, Giraudo G, Morrocchi M, Peroni C, Pirrone G, Sportelli G, Wheadon R. Full-beam performances of a PET detector with synchrotron therapeutic proton beams. Phys Med Biol 2016; 61:N650-N666. [PMID: 27819254 DOI: 10.1088/0031-9155/61/23/n650] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Treatment quality assessment is a crucial feature for both present and next-generation ion therapy facilities. Several approaches are being explored, based on prompt radiation emission or on PET signals by [Formula: see text]-decaying isotopes generated by beam interactions with the body. In-beam PET monitoring at synchrotron-based ion therapy facilities has already been performed, either based on inter-spill data only, to avoid the influence of the prompt radiation, or including both in-spill and inter-spill data. However, the PET images either suffer of poor statistics (inter-spill) or are more influenced by the background induced by prompt radiation (in-spill). Both those problems are expected to worsen for accelerators with improved duty cycle where the inter-spill interval is reduced to shorten the treatment time. With the aim of assessing the detector performance and developing techniques for background reduction, a test of an in-beam PET detector prototype was performed at the CNAO synchrotron-based ion therapy facility in full-beam acquisition modality. Data taken with proton beams impinging on PMMA phantoms showed the system acquisition capability and the resulting activity distribution, separately reconstructed for the in-spill and the inter-spill data. The coincidence time resolution for in-spill and inter-spill data shows a good agreement, with a slight deterioration during the spill. The data selection technique allows the identification and rejection of most of the background originated during the beam delivery. The activity range difference between two different proton beam energies (68 and 72 MeV) was measured and found to be in sub-millimeter agreement with the expected result. However, a slightly longer (2 mm) absolute profile length is obtained for in-spill data when compared to inter-spill data.
Collapse
Affiliation(s)
- M A Piliero
- Department of Physics, University of Pisa, Pisa, Italy. INFN, Pisa, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
49
|
Priegnitz M, Barczyk S, Nenoff L, Golnik C, Keitz I, Werner T, Mein S, Smeets J, Vander Stappen F, Janssens G, Hotoiu L, Fiedler F, Prieels D, Enghardt W, Pausch G, Richter C. Towards clinical application: prompt gamma imaging of passively scattered proton fields with a knife-edge slit camera. Phys Med Biol 2016; 61:7881-7905. [PMID: 27779120 DOI: 10.1088/0031-9155/61/22/7881] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Prompt γ-ray imaging with a knife-edge shaped slit camera provides the possibility of verifying proton beam range in tumor therapy. Dedicated experiments regarding the characterization of the camera system have been performed previously. Now, we aim at implementing the prototype into clinical application of monitoring patient treatments. Focused on this goal of translation into clinical operation, we systematically addressed remaining challenges and questions. We developed a robust energy calibration routine and corresponding quality assurance protocols. Furthermore, with dedicated experiments, we determined the positioning precision of the system to 1.1 mm (2σ). For the first time, we demonstrated the application of the slit camera, which was intentionally developed for pencil beam scanning, to double scattered proton beams. Systematic experiments with increasing complexity were performed. It was possible to visualize proton range shifts of 2-5 mm with the camera system in phantom experiments in passive scattered fields. Moreover, prompt γ-ray profiles for single iso-energy layers were acquired by synchronizing time resolved measurements to the rotation of the range modulator wheel of the treatment system. Thus, a mapping of the acquired profiles to different anatomical regions along the beam path is feasible and additional information on the source of potential range shifts can be obtained. With the work presented here, we show that an application of the slit camera in clinical treatments is possible and of potential benefit.
Collapse
Affiliation(s)
- M Priegnitz
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, Bautzner Landstraße 400, 01328 Dresden, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Huisman BFB, Létang JM, Testa É, Sarrut D. Accelerated prompt gamma estimation for clinical proton therapy simulations. Phys Med Biol 2016; 61:7725-7743. [DOI: 10.1088/0031-9155/61/21/7725] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|