1
|
Veit-Haibach P, Ahlström H, Boellaard R, Delgado Bolton RC, Hesse S, Hope T, Huellner MW, Iagaru A, Johnson GB, Kjaer A, Law I, Metser U, Quick HH, Sattler B, Umutlu L, Zaharchuk G, Herrmann K. International EANM-SNMMI-ISMRM consensus recommendation for PET/MRI in oncology. Eur J Nucl Med Mol Imaging 2023; 50:3513-3537. [PMID: 37624384 PMCID: PMC10547645 DOI: 10.1007/s00259-023-06406-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023]
Abstract
PREAMBLE The Society of Nuclear Medicine and Molecular Imaging (SNMMI) is an international scientific and professional organization founded in 1954 to promote the science, technology, and practical application of nuclear medicine. The European Association of Nuclear Medicine (EANM) is a professional non-profit medical association that facilitates communication worldwide between individuals pursuing clinical and research excellence in nuclear medicine. The EANM was founded in 1985. The merged International Society for Magnetic Resonance in Medicine (ISMRM) is an international, nonprofit, scientific association whose purpose is to promote communication, research, development, and applications in the field of magnetic resonance in medicine and biology and other related topics and to develop and provide channels and facilities for continuing education in the field.The ISMRM was founded in 1994 through the merger of the Society of Magnetic Resonance in Medicine and the Society of Magnetic Resonance Imaging. SNMMI, ISMRM, and EANM members are physicians, technologists, and scientists specializing in the research and practice of nuclear medicine and/or magnetic resonance imaging. The SNMMI, ISMRM, and EANM will periodically define new guidelines for nuclear medicine practice to help advance the science of nuclear medicine and/or magnetic resonance imaging and to improve the quality of service to patients throughout the world. Existing practice guidelines will be reviewed for revision or renewal, as appropriate, on their fifth anniversary or sooner, if indicated. Each practice guideline, representing a policy statement by the SNMMI/EANM/ISMRM, has undergone a thorough consensus process in which it has been subjected to extensive review. The SNMMI, ISMRM, and EANM recognize that the safe and effective use of diagnostic nuclear medicine imaging and magnetic resonance imaging requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guideline by those entities not providing these services is not authorized. These guidelines are an educational tool designed to assist practitioners in providing appropriate care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. For these reasons and those set forth below, the SNMMI, the ISMRM, and the EANM caution against the use of these guidelines in litigation in which the clinical decisions of a practitioner are called into question. The ultimate judgment regarding the propriety of any specific procedure or course of action must be made by the physician or medical physicist in light of all the circumstances presented. Thus, there is no implication that an approach differing from the guidelines, standing alone, is below the standard of care. To the contrary, a conscientious practitioner may responsibly adopt a course of action different from that set forth in the guidelines when, in the reasonable judgment of the practitioner, such course of action is indicated by the condition of the patient, limitations of available resources, or advances in knowledge or technology subsequent to publication of the guidelines. The practice of medicine includes both the art and the science of the prevention, diagnosis, alleviation, and treatment of disease. The variety and complexity of human conditions make it impossible to always reach the most appropriate diagnosis or to predict with certainty a particular response to treatment. Therefore, it should be recognized that adherence to these guidelines will not ensure an accurate diagnosis or a successful outcome. All that should be expected is that the practitioner will follow a reasonable course of action based on current knowledge, available resources, and the needs of the patient to deliver effective and safe medical care. The sole purpose of these guidelines is to assist practitioners in achieving this objective.
Collapse
Affiliation(s)
- Patrick Veit-Haibach
- Joint Department Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, Toronto General Hospital, 1 PMB-275, 585 University Avenue, Toronto, Ontario, M5G 2N2, Canada
- Joint Department of Medical Imaging, University of Toronto, Toronto, Canada
| | - Håkan Ahlström
- Department of Surgical Sciences, Uppsala University, 751 85, Uppsala, Sweden
- Antaros Medical AB, BioVenture Hub, 431 53, Mölndal, Sweden
| | - Ronald Boellaard
- Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, The Netherlands
- Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
| | - Roberto C Delgado Bolton
- Department of Diagnostic Imaging (Radiology) and Nuclear Medicine, University Hospital San Pedro and Centre for Biomedical Research of La Rioja (CIBIR), Logroño, La Rioja, Spain
| | - Swen Hesse
- Department of Nuclear Medicine, University of Leipzig Medical Center, Leipzig, Germany
| | - Thomas Hope
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA
| | - Martin W Huellner
- Department of Nuclear Medicine, University Hospital Zürich, University of Zürich, Rämistrasse 100, 8091, Zurich, Switzerland
| | - Andrei Iagaru
- Department of Radiology, Division of Nuclear Medicine, Stanford University Medical Center, Stanford, CA, USA
| | - Geoffrey B Johnson
- Division of Nuclear Medicine, Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Andreas Kjaer
- Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Rigshospitalet and University of Copenhagen, Copenhagen, Denmark
| | - Ian Law
- Department of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, Copenhagen, Denmark
| | - Ur Metser
- Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Harald H Quick
- High-Field and Hybrid MR Imaging, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
- Erwin L. Hahn Institute for MR Imaging, University of Duisburg-Essen, Essen, Germany
| | - Bernhard Sattler
- Department of Nuclear Medicine, University Hospital Leipzig, Leipzig, Germany
| | - Lale Umutlu
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Greg Zaharchuk
- Division of Neuroradiology, Department of Radiology, Stanford University, 300 Pasteur Drive, Room S047, Stanford, CA, 94305-5105, USA
| | - Ken Herrmann
- Department of Nuclear Medicine, University of Duisburg-Essen and German Cancer Consortium (DKTK), University Hospital Essen, Essen, Germany.
| |
Collapse
|
2
|
Min LA, Castagnoli F, Vogel WV, Vellenga JP, van Griethuysen JJM, Lahaye MJ, Maas M, Beets Tan RGH, Lambregts DMJ. A decade of multi-modality PET and MR imaging in abdominal oncology. Br J Radiol 2021; 94:20201351. [PMID: 34387508 PMCID: PMC9328040 DOI: 10.1259/bjr.20201351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To investigate trends observed in a decade of published research on multimodality PET(/CT)+MR imaging in abdominal oncology, and to explore how these trends are reflected by the use of multimodality imaging performed at our institution. METHODS First, we performed a literature search (2009-2018) including all papers published on the multimodality combination of PET(/CT) and MRI in abdominal oncology. Retrieved papers were categorized according to a structured labelling system, including study design and outcome, cancer and lesion type under investigation and PET-tracer type. Results were analysed using descriptive statistics and evolutions over time were plotted graphically. Second, we performed a descriptive analysis of the numbers of MRI, PET/CT and multimodality PET/CT+MRI combinations (performed within a ≤14 days interval) performed during a similar time span at our institution. RESULTS Published research papers involving multimodality PET(/CT)+MRI combinations showed an impressive increase in numbers, both for retrospective combinations of PET/CT and MRI, as well as hybrid PET/MRI. Main areas of research included new PET-tracers, visual PET(/CT)+MRI assessment for staging, and (semi-)quantitative analysis of PET-parameters compared to or combined with MRI-parameters as predictive biomarkers. In line with literature, we also observed a vast increase in numbers of multimodality PET/CT+MRI imaging in our institutional data. CONCLUSIONS The tremendous increase in published literature on multimodality imaging, reflected by our institutional data, shows the continuously growing interest in comprehensive multivariable imaging evaluations to guide oncological practice. ADVANCES IN KNOWLEDGE The role of multimodality imaging in oncology is rapidly evolving. This paper summarizes the main applications and recent developments in multimodality imaging, with a specific focus on the combination of PET+MRI in abdominal oncology.
Collapse
Affiliation(s)
- Lisa A Min
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.,GROW School for Oncology and Developmental Biology, University of Maastricht, Maastricht, The Netherlands
| | | | - Wouter V Vogel
- Department of Nuclear Medicine, The Netherlands Cancer Institute, Amsterdam, The Netherlands.,Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Jisk P Vellenga
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.,Department of Nuclear Medicine, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Joost J M van Griethuysen
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.,GROW School for Oncology and Developmental Biology, University of Maastricht, Maastricht, The Netherlands
| | - Max J Lahaye
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Monique Maas
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Regina G H Beets Tan
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.,GROW School for Oncology and Developmental Biology, University of Maastricht, Maastricht, The Netherlands.,Faculty or Health Sciences, University of Southern Denmark, Odense, Denmark
| | - Doenja M J Lambregts
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| |
Collapse
|
3
|
Zhao J, Xue Q, Chen X, You Z, Wang Z, Yuan J, Liu H, Hu L. Evaluation of SUVlean consistency in FDG and PSMA PET/MR with Dixon-, James-, and Janma-based lean body mass correction. EJNMMI Phys 2021; 8:17. [PMID: 33598849 PMCID: PMC7889776 DOI: 10.1186/s40658-021-00363-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 02/04/2021] [Indexed: 01/22/2023] Open
Abstract
PURPOSE To systematically evaluate the consistency of various standardized uptake value (SUV) lean body mass (LBM) normalization methods in a clinical positron emission tomography/magnetic resonance imaging (PET/MR) setting. METHODS SUV of brain, liver, prostate, parotid, blood, and muscle were measured in 90 18F-FDG and 28 18F-PSMA PET/MR scans and corrected for LBM using the James, Janma (short for Janmahasatian), and Dixon approaches. The prospective study was performed from December 2018 to August 2020 at Shanghai East Hospital. Forty dual energy X-ray absorptiometry (DXA) measurements of non-fat mass were used as the reference standard. Agreement between different LBM methods was assessed by linear regression and Bland-Altman statistics. SUV's dependency on BMI was evaluated by means of linear regression and Pearson correlation. RESULTS Compared to DXA, the Dixon approach presented the least bias in LBM/weight% than James and Janma models (bias 0.4±7.3%, - 8.0±9.4%, and - 3.3±8.3% respectively). SUV normalized by body weight (SUVbw) was positively correlated with body mass index (BMI) for both FDG (e.g., liver: r = 0.45, p < 0.001) and PSMA scans (r = 0.20, p = 0.31), while SUV normalized by lean body mass (SUVlean) revealed a decreased dependency on BMI (r = 0.22, 0.08, 0.14, p = 0.04, 0.46, 0.18 for Dixon, James, and Janma models, respectively). The liver SUVbw of obese/overweight patients was significantly larger (p < 0.001) than that of normal patients, whereas the bias was mostly eliminated in SUVlean. One-way ANOVA showed significant difference (p < 0.001) between SUVlean in major organs measured using Dixon method vs James and Janma models. CONCLUSION Significant systematic variation was found using different approaches to calculate SUVlean. A consistent correction method should be applied for serial PET/MR scans. The Dixon method provides the most accurate measure of LBM, yielding the least bias of all approaches when compared to DXA.
Collapse
Affiliation(s)
- Jun Zhao
- Department of Nuclear Medicine, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
| | - Qiaoyi Xue
- Central Research Institute, United Imaging Healthcare Group, Shanghai, China
| | - Xing Chen
- Department of Nuclear Medicine, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
| | - Zhiwen You
- Department of Nuclear Medicine, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
| | - Zhe Wang
- Central Research Institute, United Imaging Healthcare Group, Shanghai, China
| | - Jianmin Yuan
- Central Research Institute, United Imaging Healthcare Group, Shanghai, China
| | - Hui Liu
- Central Research Institute, United Imaging Healthcare Group, Shanghai, China
| | - Lingzhi Hu
- Central Research Institute, United Imaging Healthcare Group, Shanghai, China
| |
Collapse
|
4
|
Watanabe T, Kano D, Enomoto R, Muraishi H, Wakamatsu R, Katagiri H, Kagaya M, Kondo R, Fukushi M, Hosokawa S, Takeda T, Tanaka MM, Uchida T, Nakagami Y. Remote measurement of urinary radioactivity in
18
F-FDG PET patients using Compton camera for accuracy evaluation of standardized uptake value. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aae6b8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
5
|
Aiello M, Cavaliere C, Marchitelli R, d'Albore A, De Vita E, Salvatore M. Hybrid PET/MRI Methodology. INTERNATIONAL REVIEW OF NEUROBIOLOGY 2018; 141:97-128. [PMID: 30314608 DOI: 10.1016/bs.irn.2018.07.026] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
The hybrid PET/MR scanner represents the first implementation of the effective integration of two modalities allowing truly synchronous/simultaneous acquisition of their imaging signals. This integration, resulting from the innovation and development of specific hardware components has paved the way for new approaches in the study of neurodegenerative diseases. This chapter will describe the hardware development that has led to the availability of different clinical solutions for PET/MR imaging as well as the still-open technological challenges and opportunities related to the processing and exploitation of the simultaneous acquisition in neurological studies.
Collapse
Affiliation(s)
| | | | | | | | - Enrico De Vita
- Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King's College London, King's Health Partners, St Thomas' Hospital, London, United Kingdom
| | | |
Collapse
|
6
|
Devriese J, Beels L, Maes A, Van de Wiele C, Pottel H. Evaluation of CT-based SUV normalization. Phys Med Biol 2016; 61:6369-83. [DOI: 10.1088/0031-9155/61/17/6369] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
7
|
Rausch I, Rust P, DiFranco MD, Lassen M, Stadlbauer A, Mayerhoefer ME, Hartenbach M, Hacker M, Beyer T. Reproducibility of MRI Dixon-Based Attenuation Correction in Combined PET/MR with Applications for Lean Body Mass Estimation. J Nucl Med 2016; 57:1096-101. [DOI: 10.2967/jnumed.115.168294] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Accepted: 02/08/2016] [Indexed: 01/09/2023] Open
|
8
|
Miles K, McQueen L, Ngai S, Law P. Evidence-based medicine and clinical fluorodeoxyglucose PET/MRI in oncology. Cancer Imaging 2015; 15:18. [PMID: 26578188 PMCID: PMC4650106 DOI: 10.1186/s40644-015-0053-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Accepted: 10/30/2015] [Indexed: 01/25/2023] Open
Abstract
Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) is a hybrid of two technologies each with its own evidence for clinical effectiveness. This article amalgamates evidence for clinical effectiveness of fluorodeoxyglucose (FDG) PET/CT and MRI as separate modalities with current evidence for hybrid PET/MRI and considers whether such an approach might provide a stronger case for the clinical use of PET/MRI at an earlier stage. Because links between diagnostic accuracy and health outcomes have already been established for FDG-PET/CT in the investigation of suspected residual or recurrent malignancies, evidence showing improved diagnostic performance and therapeutic impact from the use of PET/MRI as an alternative would imply clinical effectiveness of this modality for this application. A meta-analysis of studies comparing FDG-PET/CT to MRI in patients with suspected residual disease or recurrence of tumours indicates complementary roles for these modalities. PET demonstrates greater sensitivity for recurrence within lymph nodes whereas MRI is more effective that PET/CT in the detection of skeletal and hepatic recurrence. A review of studies assessing therapeutic impact of PET/MRI suggests a greater likelihood for change in clinical management when PET/MRI is used for assessment of suspected residual or recurrent disease rather than tumour staging. Supplementing the evidence-base for FDG-PET/MRI with studies that compare the components of this hybrid technology deployed separately indicates that FDG-PET/MRI is likely to be clinical effective for the investigation of patients with a range of suspected residual or recurrent cancers. This indication should therefore be prioritised for further health technology assessment.
Collapse
Affiliation(s)
- Kenneth Miles
- Department of Diagnostic Imaging, Princess Alexandra Hospital, Woolloongabba, Brisbane, Australia. .,Institute of Nuclear Medicine, University College London, London, UK.
| | - Liam McQueen
- Department of Health, Health Technology Assessment & Evaluation, Queensland Government, Herston, Brisbane, Australia
| | - Stanley Ngai
- Department of Diagnostic Imaging, Princess Alexandra Hospital, Woolloongabba, Brisbane, Australia
| | - Phillip Law
- Department of Diagnostic Imaging, Princess Alexandra Hospital, Woolloongabba, Brisbane, Australia
| |
Collapse
|