1
|
Han L, Wang Y, Chen K, Gao H, Xia K, Ge Q, Yang J, Shi W, Ruan C. Detection of In Vivo-like Cells by a Biosensor Chip Based on Metamaterials in Terahertz Regime. BIOSENSORS 2024; 14:230. [PMID: 38785704 PMCID: PMC11117974 DOI: 10.3390/bios14050230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 04/27/2024] [Accepted: 04/29/2024] [Indexed: 05/25/2024]
Abstract
Early diagnosis of diseases, especially cancer, is critical for effective treatment. The unique properties of terahertz technology have attracted attention in this field. However, current terahertz bio-detection methods face challenges due to differences between the test environment and the actual in vivo conditions. In this study, a novel method is proposed for detecting in vivo-like cells using a biosensor chip composed of metamaterials and a cavity. The cavity has a thickness of ~50 μm. The structure can protect cells from damage and provides a liquid environment like an in vivo state. Through simulation analysis, the metamaterials sensor exhibits a theoretical sensitivity of 0.287 THz/RIU (Refractive Index Unit) with a 50 μm thick analyte. The detection method is experimentally validated using the apoptosis of glioma cells and various cell types. The biosensor investigates the apoptosis of glioma cells under the impact of temozolomide, and the trend of the results was consistent with the Cell Counting Kit-8 method. Furthermore, at a concentration of ~5200 cells/cm2, the experimental results demonstrate that the sensor can distinguish between neurons and glioma cells with a resonance frequency difference of approximately 30 GHz. This research has significant potential for detecting glioma cells and offers an alternative approach to in vivo-like cell detection.
Collapse
Affiliation(s)
- Lulu Han
- School of Electronic and Information Engineering, Beihang University, Beijing 100191, China; (L.H.); (K.X.)
| | - Yuchen Wang
- School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; (Y.W.); (H.G.)
| | - Kanglong Chen
- School of Electronic and Information Engineering, Beihang University, Beijing 100191, China; (L.H.); (K.X.)
| | - Hengyu Gao
- School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; (Y.W.); (H.G.)
| | - Kexin Xia
- School of Electronic and Information Engineering, Beihang University, Beijing 100191, China; (L.H.); (K.X.)
| | - Qinggang Ge
- Department of Neurosurgery, Peking University Third Hospital, Beijing 100191, China; (Q.G.); (J.Y.)
| | - Jun Yang
- Department of Neurosurgery, Peking University Third Hospital, Beijing 100191, China; (Q.G.); (J.Y.)
- Center for Precision Neurosurgery and Oncology of Peking University Health Science Center, Beijing 100191, China
| | - Wei Shi
- School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China; (Y.W.); (H.G.)
| | - Cunjun Ruan
- School of Electronic and Information Engineering, Beihang University, Beijing 100191, China; (L.H.); (K.X.)
- Beijing Key Laboratory for Microwave Sensing and Security Applications, Beihang University, Beijing 100191, China
| |
Collapse
|
2
|
Chernomyrdin NV, Il'enkova DR, Zhelnov VA, Alekseeva AI, Gavdush AA, Musina GR, Nikitin PV, Kucheryavenko AS, Dolganova IN, Spektor IE, Tuchin VV, Zaytsev KI. Quantitative polarization-sensitive super-resolution solid immersion microscopy reveals biological tissues' birefringence in the terahertz range. Sci Rep 2023; 13:16596. [PMID: 37789192 PMCID: PMC10547778 DOI: 10.1038/s41598-023-43857-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 09/29/2023] [Indexed: 10/05/2023] Open
Abstract
Terahertz (THz) technology offers a variety of applications in label-free medical diagnosis and therapy, majority of which rely on the effective medium theory that assumes biological tissues to be optically isotropic and homogeneous at the scale posed by the THz wavelengths. Meanwhile, most recent research discovered mesoscale ([Formula: see text]) heterogeneities of tissues; [Formula: see text] is a wavelength. This posed a problem of studying the related scattering and polarization effects of THz-wave-tissue interactions, while there is still a lack of appropriate tools and instruments for such studies. To address this challenge, in this paper, quantitative polarization-sensitive reflection-mode THz solid immersion (SI) microscope is developed, that comprises a silicon hemisphere-based SI lens, metal-wire-grid polarizer and analyzer, a continuous-wave 0.6 THz ([Formula: see text] µm) backward-wave oscillator (BWO), and a Golay detector. It makes possible the study of local polarization-dependent THz response of mesoscale tissue elements with the resolution as high as [Formula: see text]. It is applied to retrieve the refractive index distributions over the freshly-excised rat brain for the two orthogonal linear polarizations of the THz beam, aimed at uncovering the THz birefringence (structural optical anisotropy) of tissues. The most pronounced birefringence is observed for the Corpus callosum, formed by well-oriented and densely-packed axons bridging the cerebral hemispheres. The observed results are verified by the THz pulsed spectroscopy of the porcine brain, which confirms higher refractive index of the Corpus callosum when the THz beam is polarized along axons. Our findings highlight a potential of the quantitative polarization THz microscopy in biophotonics and medical imaging.
Collapse
Affiliation(s)
- N V Chernomyrdin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia, 119991.
| | - D R Il'enkova
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia, 119991
| | - V A Zhelnov
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia, 119991
| | - A I Alekseeva
- Research Institute of Human Morphology, Moscow, Russia, 117418
| | - A A Gavdush
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia, 119991
| | - G R Musina
- Department of Biomedical Engineering, University of Houston, Houston, TX, USA
- Department of Integrative Physiology, Baylor College of Medicine, Houston, TX, USA
| | - P V Nikitin
- Department of Biomedical Engineering, University of Houston, Houston, TX, USA
| | - A S Kucheryavenko
- Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | - I N Dolganova
- Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | - I E Spektor
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia, 119991
| | - V V Tuchin
- Institute of Physics and Science Medical Center, Saratov State University, Saratov, Russia, 410012
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia, 634050
| | - K I Zaytsev
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia, 119991.
| |
Collapse
|
3
|
Chakraborty D, Mills BN, Cheng J, Komissarov I, Gerber SA, Sobolewski R. Development of Terahertz Imaging Markers for Pancreatic Ductal Adenocarcinoma using Maximum A Posteriori Probability (MAP) Estimation. ACS OMEGA 2023; 8:9925-9933. [PMID: 36969433 PMCID: PMC10034990 DOI: 10.1021/acsomega.2c07080] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 02/24/2023] [Indexed: 06/18/2023]
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is one of the significant reasons for cancer-related death in the United States due to a lack of timely prognosis and the poor efficacy of the standard treatment protocol. Immunotherapy-based neoadjuvant therapy, such as stereotactic body radiotherapy (SBRT), has shown promising results compared to conventional radiotherapy in strengthening the antitumor response in PDAC. To probe and quantify the antitumor response with SBRT, we propose to study the tumor microenvironment using terahertz time-domain spectroscopy (THz-TDS). Since the tumor's complex microenvironment plays a key role in disease progression and treatment supervision, THz-TDS can be a revolutionary tool to help in treatment planning by probing the changes in the tissue microenvironment. This paper presents THz-TDS of paraffin-embedded PDAC samples utilizing a clinically relevant genetically engineered mouse model. This Article aims to develop and validate a novel time-domain approximation method based on maximum a posteriori probability (MAP) estimation to extract terahertz parameters, namely, the refractive index and the absorption coefficient, from THz-TDS. Unlike the standard frequency-domain (FD) analysis, the parameters extracted from MAP construct better-conserved tissue parameters estimates, since the FD optimization often incorporates errors due to numerical instabilities during phase unwrapping, especially when propagating in lossy media. The THz-range index of refraction extracted from MAP and absorption coefficient parameters report a statistically significant distinction between PDAC tissue regions and their healthy equivalents. The coefficient of variation of the refractive index extracted by MAP is one order of magnitude lower compared to the one extracted from FD analysis. The index of refraction and absorption coefficient extracted from the MAP are suggested as the best imaging markers to reconstruct THz images of biological tissues to reflect their physical properties accurately and reproducibly. The obtained THz scans were validated using standard histopathology.
Collapse
Affiliation(s)
- Debamitra Chakraborty
- Materials
Science Graduate Program, University of
Rochester, Rochester, New York 14627-1299, USA
- Laboratory
for Laser Energetics, University of Rochester, Rochester, New York 14623, USA
| | - Bradley N. Mills
- Department
of Surgery, University of Rochester Medical
Center, Rochester, New York 14642, USA
| | - Jing Cheng
- Materials
Science Graduate Program, University of
Rochester, Rochester, New York 14627-1299, USA
- Laboratory
for Laser Energetics, University of Rochester, Rochester, New York 14623, USA
| | - Ivan Komissarov
- Laboratory
for Laser Energetics, University of Rochester, Rochester, New York 14623, USA
- Department of
Electrical and Computer Engineering and Department of Physics, University
of Rochester, Rochester, New York 14627-0231, USA
| | - Scott A. Gerber
- Department
of Surgery, University of Rochester Medical
Center, Rochester, New York 14642, USA
| | - Roman Sobolewski
- Materials
Science Graduate Program, University of
Rochester, Rochester, New York 14627-1299, USA
- Laboratory
for Laser Energetics, University of Rochester, Rochester, New York 14623, USA
- Department of
Electrical and Computer Engineering and Department of Physics, University
of Rochester, Rochester, New York 14627-0231, USA
| |
Collapse
|
4
|
Martins IS, Silva HF, Lazareva EN, Chernomyrdin NV, Zaytsev KI, Oliveira LM, Tuchin VV. Measurement of tissue optical properties in a wide spectral range: a review [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:249-298. [PMID: 36698664 PMCID: PMC9841994 DOI: 10.1364/boe.479320] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/29/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
A distinctive feature of this review is a critical analysis of methods and results of measurements of the optical properties of tissues in a wide spectral range from deep UV to terahertz waves. Much attention is paid to measurements of the refractive index of biological tissues and liquids, the knowledge of which is necessary for the effective application of many methods of optical imaging and diagnostics. The optical parameters of healthy and pathological tissues are presented, and the reasons for their differences are discussed, which is important for the discrimination of pathologies and the demarcation of their boundaries. When considering the interaction of terahertz radiation with tissues, the concept of an effective medium is discussed, and relaxation models of the effective optical properties of tissues are presented. Attention is drawn to the manifestation of the scattering properties of tissues in the THz range and the problems of measuring the optical properties of tissues in this range are discussed. In conclusion, a method for the dynamic analysis of the optical properties of tissues under optical clearing using an application of immersion agents is presented. The main mechanisms and technologies of optical clearing, as well as examples of the successful application for differentiation of healthy and pathological tissues, are analyzed.
Collapse
Affiliation(s)
- Inês S. Martins
- Center for Innovation in Engineering and Industrial Technology, ISEP, Porto, Portugal
| | - Hugo F. Silva
- Porto University, School of Engineering, Porto, Portugal
| | - Ekaterina N. Lazareva
- Science Medical Center, Saratov State University, Saratov, Russia
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia
| | | | - Kirill I. Zaytsev
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - Luís M. Oliveira
- Physics Department, Polytechnic of Porto – School of Engineering (ISEP), Porto, Portugal
- Institute for Systems and Computer Engineering, Technology and Science (INESC TEC), Porto, Portugal
| | - Valery V. Tuchin
- Science Medical Center, Saratov State University, Saratov, Russia
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia
| |
Collapse
|
5
|
Shi H, Li T, Liu Z, Zhao J, Qi F. Early detection of gastric cancer via high-resolution terahertz imaging system. Front Bioeng Biotechnol 2022; 10:1052069. [PMID: 36588946 PMCID: PMC9794757 DOI: 10.3389/fbioe.2022.1052069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 11/28/2022] [Indexed: 12/15/2022] Open
Abstract
Terahertz (THz) wave has demonstrated a good prospect in recent years, but the resolution is still one of the problems that restrict the application of THz technology in medical imaging. Paraffin-embedded samples are mostly used in THz medical imaging studies, which are thicker and significantly different from the current gold standard slice pathological examination in sample preparation. In addition, THz absorption in different layers of normal and cancerous tissues also remains to be further explored. In this study, we constructed a high-resolution THz imaging system to scan non-tumorous adjacent tissue slices and gastric cancer (GC) tissue slices. In this system, a THz quantum cascade laser emitted a pulsed 3 THz signal and the transmitted THz wave was received by a THz detector implemented in a 65 nm CMOS process. The slice thickness was only 20 μm, which was close to that of the medical pathology examination. We successfully found THz transmittance differences between different layers of normal gastric tissues based on THz images, and the resolution could reach 60 μm for the first time. The results indicated that submucosa had a lower THz transmittance than that of mucosa and muscular layer in non-tumorous adjacent tissue. However, in GC tissue, THz transmittance of mucosa and submucosa was similar, caused by the decreased transmittance of mucosa, where the cancer occurs. Therefore, we suppose that the similar terahertz transmittance between gastric mucosa and submucosa may indicate the appearance of cancerization. The images obtained from our THz imaging system were clearer than those observed with naked eyes, and can be directly compared with microscopic images. This is the first application of THz imaging technology to identify non-tumorous adjacent tissue and GC tissue based on the difference in THz wave absorption between different layers in the tissue. Our present work not only demonstrated the potential of THz imaging to promote early diagnosis of GC, but also suggested a new direction for the identification of normal and cancerous tissues by analyzing differences in THz transmittance between different layers of tissue.
Collapse
Affiliation(s)
- Han Shi
- Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
- Department of Surgical Oncology and General Surgery, the First Hospital of China Medical University, Shenyang, China
- Key Laboratory of Precision Diagnosis and Treatment of Gastrointestinal Tumors (China Medical University), Ministry of Education, Shenyang, China
| | - Tenghui Li
- Department of Surgical Oncology and General Surgery, the First Hospital of China Medical University, Shenyang, China
- Key Laboratory of Precision Diagnosis and Treatment of Gastrointestinal Tumors (China Medical University), Ministry of Education, Shenyang, China
| | - Zhaoyang Liu
- Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
- Key Laboratory of Terahertz Imaging and Sensing, Liaoning Province, Shenyang, China
| | - Junhua Zhao
- Department of Surgical Oncology and General Surgery, the First Hospital of China Medical University, Shenyang, China
- Key Laboratory of Precision Diagnosis and Treatment of Gastrointestinal Tumors (China Medical University), Ministry of Education, Shenyang, China
| | - Feng Qi
- Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
- Key Laboratory of Terahertz Imaging and Sensing, Liaoning Province, Shenyang, China
| |
Collapse
|
6
|
Cai J, Guang M, Zhou J, Qu Y, Xu H, Sun Y, Xiong H, Liu S, Chen X, Jin J, Wu X. Dental caries diagnosis using terahertz spectroscopy and birefringence. OPTICS EXPRESS 2022; 30:13134-13147. [PMID: 35472935 DOI: 10.1364/oe.452769] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 03/28/2022] [Indexed: 06/14/2023]
Abstract
Dental caries is a widespread chronic infectious disease which may induce a series of oral and general problems if untreated. As a result, early diagnosis and follow-up following radiation-free dental caries therapy are critical. Terahertz (THz) waves with highly penetrating and non-ionizing properties are ideally suited for dental caries diagnosis, however related research in this area is still in its infancy. Here, we successfully observe the existence of THz birefringence phenomenon in enamel and demonstrate the feasibility of utilizing THz spectroscopy and birefringence to realize caries diagnosis. By comparing THz responses between healthy teeth and caries, the transmitted THz signals in caries are evidently reduced. Concomitantly, the THz birefringence is also unambiguously inhibited when caries occurs due to the destruction of the internal hydroxyapatite crystal structure. This THz anisotropic activity is position-dependent, which can be qualitatively understood by optical microscopic imaging of dental structures. To increase the accuracy of THz technology in detecting dental caries and stimulate the development of THz caries instruments, the presence of significant THz birefringence effect induced anisotropy in enamel, in combination with the strong THz attenuation at the caries, may be used as a new tool for caries diagnosis.
Collapse
|
7
|
Komandin GA, Zaytsev KI, Dolganova IN, Nozdrin VS, Chuchupal SV, Anzin VB, Spektor IE. Quantification of solid-phase chemical reactions using the temperature-dependent terahertz pulsed spectroscopy, sum rule, and Arrhenius theory: thermal decomposition of α-lactose monohydrate. OPTICS EXPRESS 2022; 30:9208-9221. [PMID: 35299355 DOI: 10.1364/oe.453528] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 02/28/2022] [Indexed: 06/14/2023]
Abstract
Transformations of the low-energy vibrational spectra are associated with structural changes in an analyte and closely related to the instability of weak chemical bounds. Terahertz (THz)/far-infrared optical spectroscopy is commonly used to probe such transformation, aimed at characterization of the underlying solid-phase chemical reactions in organic compounds. However, such studies usually provide quite qualitative information about the temperature- and time-dependent parameters of absorption peaks in dielectric spectra of an analyte. In this paper, an approach for quantitative analyses of the solid-phased chemical reactions based on the THz pulsed spectroscopy was developed. It involves studying an evolution of the sample optical properties, as a function of the analyte temperature and reaction time, and relies on the classical oscillator model, the sum rule, and the Arrhenius theory. The method allows one to determine the temperature-dependent reaction rate V1(T) and activation energy Ea. To demonstrate the practical utility of this method, it was applied to study α-lactose monohydrate during its temperature-induced molecular decomposition. Analysis of the measured THz spectra revealed the increase of the reaction rate in the range of V1 ≃ ~9 × 10-4-10-2 min-1, when the analyte temperature rises from 313 to 393 K, while the Arrhenius activation energy is Ea ≃ ~45.4 kJ/mol. Thanks to a large number of obtained physical and chemical parameters, the developed approach expands capabilities of THz spectroscopy in chemical physics, analytical chemistry, and pharmaceutical industry.
Collapse
|
8
|
Mu N, Yang C, Xu D, Wang S, Ma K, Lai Y, Guo P, Zhang S, Wang Y, Feng H, Chen T, Yao J. Molecular pathological recognition of freshly excised human glioma using terahertz ATR spectroscopy. BIOMEDICAL OPTICS EXPRESS 2022; 13:222-236. [PMID: 35154866 PMCID: PMC8803014 DOI: 10.1364/boe.445111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/13/2021] [Accepted: 11/13/2021] [Indexed: 06/14/2023]
Abstract
The diagnosis and treatment of glioma depends greatly on the rapid extraction of molecular pathological features. In this study, human brain tumor tissues of different grades were analyzed using terahertz (THz) attenuated total reflectance (ATR) time-domain spectroscopy. Substantial differences in THz parameters were observed between paracarcinoma tissue and grade I-IV gliomas, Furthermore, the difference of THz absorption coefficient increases with the increase of THz frequency. It was also demonstrated that the isocitrate dehydrogenase (IDH) mutant and wild-type glioma tissues can be well distinguished using THz spectroscopy. Therefore, THz ATR spectroscopy can realize molecular typing recognition based on molecular pathology. This will provide a theoretical basis for developing intraoperative real-time glioma recognition and diagnosis technology.
Collapse
Affiliation(s)
- Ning Mu
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
- Contributed equally
| | - Chuanyan Yang
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
- Contributed equally
| | - Degang Xu
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronics Information Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Shi Wang
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Kang Ma
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Ying Lai
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Peiwen Guo
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Shuixian Zhang
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Yuye Wang
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronics Information Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Hua Feng
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Tunan Chen
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Jianquan Yao
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronics Information Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| |
Collapse
|
9
|
Wu L, Wang Y, Liao B, Zhao L, Chen K, Ge M, Li H, Chen T, Feng H, Xu D, Yao J. Temperature dependent terahertz spectroscopy and imaging of orthotopic brain gliomas in mouse models. BIOMEDICAL OPTICS EXPRESS 2022; 13:93-104. [PMID: 35154856 PMCID: PMC8803010 DOI: 10.1364/boe.445597] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 11/21/2021] [Accepted: 11/29/2021] [Indexed: 05/07/2023]
Abstract
Terahertz (THz) spectroscopy and imaging were used to differentiate brain gliomas in a mouse model at different temperatures. The THz spectral difference between brain glioma and normal brain tissues at -10°C and 20°C was obtained in the 0.4-2.53 THz range. The absorption coefficient and refractive index values varied with both temperature and frequency. The fresh ex vivo brain glioma tissues were mapped by THz attenuated total reflection (ATR) imaging at 2.52 THz in the temperature range from -20°C to 35°C. Compared with histological examination, THz-ATR imaging could better display the tumor areas at a higher temperature. And the averaged reflectivity of normal tissue was increased with the increase of temperature, whereas the tumor region showed a decreasing trend. Thus, the larger THz imaging difference between glioma and normal tissues could be obtained. Moreover, in vivo brain gliomas in mouse models could also be differentiated clearly from normal brain tissues using THz-ATR imaging at 2.52 THz under room temperature. The THz-ATR images corresponded well with those of visual and hematoxylin and eosin (H&E) stained images. Therefore, this pilot study demonstrated that temperature dependence THz spectroscopy and imaging are helpful to the brain gliomas in mouse model detection.
Collapse
Affiliation(s)
- Limin Wu
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Yuye Wang
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Bin Liao
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Lu Zhao
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Kai Chen
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Meilan Ge
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Haibin Li
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Tunan Chen
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Hua Feng
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Degang Xu
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Jianquan Yao
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| |
Collapse
|
10
|
Kucheryavenko AS, Chernomyrdin NV, Gavdush AA, Alekseeva AI, Nikitin PV, Dolganova IN, Karalkin PA, Khalansky AS, Spektor IE, Skorobogatiy M, Tuchin VV, Zaytsev KI. Terahertz dielectric spectroscopy and solid immersion microscopy of ex vivo glioma model 101.8: brain tissue heterogeneity. BIOMEDICAL OPTICS EXPRESS 2021; 12:5272-5289. [PMID: 34513256 PMCID: PMC8407834 DOI: 10.1364/boe.432758] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/15/2021] [Accepted: 07/22/2021] [Indexed: 05/23/2023]
Abstract
Terahertz (THz) technology holds strong potential for the intraoperative label-free diagnosis of brain gliomas, aimed at ensuring their gross-total resection. Nevertheless, it is still far from clinical applications due to the limited knowledge about the THz-wave-brain tissue interactions. In this work, rat glioma model 101.8 was studied ex vivo using both the THz pulsed spectroscopy and the 0.15λ-resolution THz solid immersion microscopy (λ is a free-space wavelength). The considered homograft model mimics glioblastoma, possesses heterogeneous character, unclear margins, and microvascularity. Using the THz spectroscopy, effective THz optical properties of brain tissues were studied, as averaged within the diffraction-limited beam spot. Thus measured THz optical properties revealed a persistent difference between intact tissues and a tumor, along with fluctuations of the tissue response over the rat brain. The observed THz microscopic images showed heterogeneous character of brain tissues at the scale posed by the THz wavelengths, which is due to the distinct response of white and gray matters, the presence of different neurovascular structures, as well as due to the necrotic debris and hemorrhage in a tumor. Such heterogeneities might significantly complicate delineation of tumor margins during the intraoperative THz neurodiagnosis. The presented results for the first time pose the problem of studying the inhomogeneity of brain tissues that causes scattering of THz waves, as well as the urgent need to use the radiation transfer theory for describing the THz-wave - tissue interactions.
Collapse
Affiliation(s)
- A S Kucheryavenko
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Russia
- Institute of Solid State Physics of the Russian Academy of Sciences, Russia
| | - N V Chernomyrdin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Russia
- Bauman Moscow State Technical University, Russia
| | - A A Gavdush
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Russia
- Bauman Moscow State Technical University, Russia
| | | | - P V Nikitin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Russia
- Institute for Regenerative Medicine, Sechenov University, Russia
- Burdenko Neurosurgery Institute, Russia
| | - I N Dolganova
- Institute of Solid State Physics of the Russian Academy of Sciences, Russia
- Bauman Moscow State Technical University, Russia
- Institute for Regenerative Medicine, Sechenov University, Russia
| | - P A Karalkin
- Institute for Cluster Oncology, Sechenov University, Russia
| | | | - I E Spektor
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Russia
| | - M Skorobogatiy
- Department of Engineering Physics, Polytechnique Montreal, Canada
| | - V V Tuchin
- Science Medical Center, Saratov State University, Russia
- Institute of Precision Mechanics and Control of the Russian Academy of Sciences, Russia
- National Research Tomsk State University, Russia
| | - K I Zaytsev
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Russia
- Bauman Moscow State Technical University, Russia
| |
Collapse
|
11
|
Soltani S, Guang Z, Zhang Z, Olson JJ, Robles FE. Label-free detection of brain tumors in a 9L gliosarcoma rat model using stimulated Raman scattering-spectroscopic optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210043R. [PMID: 34263579 PMCID: PMC8278780 DOI: 10.1117/1.jbo.26.7.076004] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 06/29/2021] [Indexed: 05/22/2023]
Abstract
SIGNIFICANCE In neurosurgery, it is essential to differentiate between tumor and healthy brain regions to maximize tumor resection while minimizing damage to vital healthy brain tissue. However, conventional intraoperative imaging tools used to guide neurosurgery are often unable to distinguish tumor margins, particularly in infiltrative tumor regions and low-grade gliomas. AIM The aim of this work is to assess the feasibility of a label-free molecular imaging tool called stimulated Raman scattering-spectroscopic optical coherence tomography (SRS-SOCT) to differentiate between healthy brain tissue and tumor based on (1) structural biomarkers derived from the decay rate of signals as a function of depth and (2) molecular biomarkers based on relative differences in lipid and protein composition extracted from the SRS signals. APPROACH SRS-SOCT combines the molecular sensitivity of SRS (based on vibrational spectroscopy) with the spatial and spectral multiplexing capabilities of SOCT to enable fast, spatially and spectrally resolved molecular imaging. SRS-SOCT is applied to image a 9L gliosarcoma rat tumor model, a well-characterized model that recapitulates human high-grade gliomas, including high proliferative capability, high vascularization, and infiltration at the margin. Structural and biochemical signatures acquired from SRS-SOCT are extracted to identify healthy and tumor tissues. RESULTS Data show that SRS-SOCT provides light-scattering-based signatures that correlate with the presence of tumors, similar to conventional OCT. Further, nonlinear phase changes from the SRS interaction, as measured with SRS-SOCT, provide an additional measure to clearly separate tumor tissue from healthy brain regions. We also show that the nonlinear phase signals in SRS-SOCT provide a signal-to-noise advantage over the nonlinear amplitude signals for identifying tumors. CONCLUSIONS SRS-SOCT can distinguish both spatial and spectral features that identify tumor regions in the 9L gliosarcoma rat model. This tool provides fast, label-free, nondestructive, and spatially resolved molecular information that, with future development, can potentially assist in identifying tumor margins in neurosurgery.
Collapse
Affiliation(s)
- Soheil Soltani
- Georgia Institute of Technology and Emory University, Wallace H. Coulter Department of Biomedical Engineering, Atlanta, Georgia, United States
| | - Zhe Guang
- Georgia Institute of Technology and Emory University, Wallace H. Coulter Department of Biomedical Engineering, Atlanta, Georgia, United States
| | - Zhaobin Zhang
- Emory University, Winship Cancer Institute, Atlanta, Georgia, United States
- Emory University School of Medicine, Department of Neurosurgery, Atlanta, Georgia, United States
| | - Jeffrey J. Olson
- Emory University, Winship Cancer Institute, Atlanta, Georgia, United States
- Emory University School of Medicine, Department of Neurosurgery, Atlanta, Georgia, United States
| | - Francisco E. Robles
- Georgia Institute of Technology and Emory University, Wallace H. Coulter Department of Biomedical Engineering, Atlanta, Georgia, United States
- Emory University, Winship Cancer Institute, Atlanta, Georgia, United States
- Address all correspondence to Francisco E. Robles,
| |
Collapse
|
12
|
Label-Free Observation of Micrometric Inhomogeneity of Human Breast Cancer Cell Density Using Terahertz Near-Field Microscopy. PHOTONICS 2021. [DOI: 10.3390/photonics8050151] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Terahertz-light imaging is attracting great attention as a new approach in non-invasive/non-staining biopsy of cancerous tissues. Positively, terahertz light has been shown to be sensitive to the cell density, the hydration content, and the chemical composition of biological samples. However, the spatial resolution of terahertz imaging is typically limited to several millimeters, making it difficult to apply the technology to image biological tissues which have sub-terahertz-wavelength-scale inhomogeneity. For overcoming the resolution, we have recently developed a terahertz near-field microscope with a spatial resolution of 10 µm, named scanning point terahertz source (SPoTS) microscope. In contrast to conventional far-field terahertz techniques, this microscope features the near-field interactions between samples and point terahertz sources on a sub-terahertz-wavelength scale. Herein, to evaluate the usefulness of terahertz imaging in cancer tissue biopsy in greater detail, we performed terahertz near-field imaging of a paraffin-embedded human-breast-cancer section having sub-terahertz-wavelength-scale inhomogeneity of the cancer cell density using the SPoTS microscope. The observed terahertz images successfully visualized local (~250 µm) inhomogeneities of the cell density in breast invasive ductal carcinoma. These results may bypass the terahertz limitation in terms of spatial resolution and may further motivate the application of terahertz light to cancer tissue biopsy.
Collapse
|
13
|
Abstract
This review considers glioma molecular markers in brain tissues and body fluids, shows the pathways of their formation, and describes traditional methods of analysis. The most important optical properties of glioma markers in the terahertz (THz) frequency range are also presented. New metamaterial-based technologies for molecular marker detection at THz frequencies are discussed. A variety of machine learning methods, which allow the marker detection sensitivity and differentiation of healthy and tumor tissues to be improved with the aid of THz tools, are considered. The actual results on the application of THz techniques in the intraoperative diagnosis of brain gliomas are shown. THz technologies’ potential in molecular marker detection and defining the boundaries of the glioma’s tissue is discussed.
Collapse
|
14
|
Gavdush AA, Chernomyrdin NV, Komandin GA, Dolganova IN, Nikitin PV, Musina GR, Katyba GM, Kucheryavenko AS, Reshetov IV, Potapov AA, Tuchin VV, Zaytsev KI. Terahertz dielectric spectroscopy of human brain gliomas and intact tissues ex vivo: double-Debye and double-overdamped-oscillator models of dielectric response. BIOMEDICAL OPTICS EXPRESS 2021; 12:69-83. [PMID: 33659071 PMCID: PMC7899500 DOI: 10.1364/boe.411025] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 11/25/2020] [Accepted: 11/30/2020] [Indexed: 05/07/2023]
Abstract
Terahertz (THz) technology offers novel opportunities in the intraoperative neurodiagnosis. Recently, the significant progress was achieved in the study of brain gliomas and intact tissues, highlighting a potential for THz technology in the intraoperative delineation of tumor margins. However, a lack of physical models describing the THz dielectric permittivity of healthy and pathological brain tissues restrains the further progress in this field. In the present work, the ex vivo THz dielectric response of human brain tissues was analyzed using relaxation models of complex dielectric permittivity. Dielectric response of tissues was parametrized by a pair of the Debye relaxators and a pair of the overdamped-oscillators - namely, the double-Debye (DD) and double-overdamped-oscillator (DO) models. Both models accurately reproduce the experimental curves for the intact tissues and the WHO Grades I-IV gliomas. While the DD model is more common for THz biophotonics, the DO model is more physically rigorous, since it satisfies the sum rule. In this way, the DO model and the sum rule were, then, applied to estimate the content of water in intact tissues and gliomas ex vivo. The observed results agreed well with the earlier-reported data, justifying water as a main endogenous label of brain tumors in the THz range. The developed models can be used to describe completely the THz-wave - human brain tissues interactions in the frameworks of classical electrodynamics, being quite important for further research and developments in THz neurodiagnosis of tumors.
Collapse
Affiliation(s)
- A A Gavdush
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - N V Chernomyrdin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
- Institute for Regenerative Medicine, Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - G A Komandin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - I N Dolganova
- Institute for Regenerative Medicine, Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
- Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | - P V Nikitin
- P.K. Anokhin Institute of Normal Physiology, Moscow, Russia
| | - G R Musina
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - G M Katyba
- Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | - A S Kucheryavenko
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
- Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | - I V Reshetov
- Institute for Cluster Oncology, Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - A A Potapov
- Burdenko Neurosurgery Institute, Moscow, Russia
| | - V V Tuchin
- Saratov State University, Saratov, Russia
- Institute of Precision Mechanics and Control of the Russian Academy of Sciences, Saratov, Russia
- National Research Tomsk State University, Tomsk, Russia
| | - K I Zaytsev
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| |
Collapse
|
15
|
Peng Y, Shi C, Wu X, Zhu Y, Zhuang S. Terahertz Imaging and Spectroscopy in Cancer Diagnostics: A Technical Review. BME FRONTIERS 2020; 2020:2547609. [PMID: 37849968 PMCID: PMC10521734 DOI: 10.34133/2020/2547609] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 08/31/2020] [Indexed: 10/19/2023] Open
Abstract
Terahertz (THz) waves are electromagnetic waves with frequency in the range from 0.1 to 10 THz. THz waves have great potential in the biomedical field, especially in cancer diagnosis, because they exhibit low ionization energy and can be used to discern most biomolecules based on their spectral fingerprints. In this paper, we review the recent progress in two applications of THz waves in cancer diagnosis: imaging and spectroscopy. THz imaging is expected to help researchers and doctors attain a direct intuitive understanding of a cancerous area. THz spectroscopy is an efficient tool for component analysis of tissue samples to identify cancer biomarkers. Additionally, the advantages and disadvantages of the developed technologies for cancer diagnosis are discussed. Furthermore, auxiliary techniques that have been used to enhance the spectral signal-to-noise ratio (SNR) are also reviewed.
Collapse
Affiliation(s)
- Yan Peng
- Terahertz Technology Innovation Research Institute, Shanghai Key Lab of Modern Optical System, Terahertz Science Cooperative Innovation Center, University of Shanghai for Science and Technology, Shanghai Institute of Intelligent Science and Technology, Tongji University, Shanghai, China
| | - Chenjun Shi
- Terahertz Technology Innovation Research Institute, Shanghai Key Lab of Modern Optical System, Terahertz Science Cooperative Innovation Center, University of Shanghai for Science and Technology, Shanghai Institute of Intelligent Science and Technology, Tongji University, Shanghai, China
| | - Xu Wu
- Terahertz Technology Innovation Research Institute, Shanghai Key Lab of Modern Optical System, Terahertz Science Cooperative Innovation Center, University of Shanghai for Science and Technology, Shanghai Institute of Intelligent Science and Technology, Tongji University, Shanghai, China
| | - Yiming Zhu
- Terahertz Technology Innovation Research Institute, Shanghai Key Lab of Modern Optical System, Terahertz Science Cooperative Innovation Center, University of Shanghai for Science and Technology, Shanghai Institute of Intelligent Science and Technology, Tongji University, Shanghai, China
| | - Songlin Zhuang
- Terahertz Technology Innovation Research Institute, Shanghai Key Lab of Modern Optical System, Terahertz Science Cooperative Innovation Center, University of Shanghai for Science and Technology, Shanghai Institute of Intelligent Science and Technology, Tongji University, Shanghai, China
| |
Collapse
|
16
|
Li D, Yang Z, Fu A, Chen T, Chen L, Tang M, Zhang H, Mu N, Wang S, Liang G, Wang H. Detecting melanoma with a terahertz spectroscopy imaging technique. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 234:118229. [PMID: 32193158 DOI: 10.1016/j.saa.2020.118229] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 02/22/2020] [Accepted: 03/03/2020] [Indexed: 05/18/2023]
Abstract
Transmission mode terahertz time-domain spectroscopy system was employed to image BALB/c mouse skin tissue slices containing melanoma. The melanoma was unambiguously identified in the frequency region of 0.6-1.8 THz because melanoma has a higher refractive index as well as a higher absorption coefficient than the normal region of the skin tissue. Based on the results of hematoxylin-eosin staining and mass weighing, it was further suggested that the higher density of nucleic acids, higher water content, and lower fat content in the melanoma compared to the normal region are major factors responsible for melanoma's higher refractive index and absorption coefficient than normal tissue. The present work validates that terahertz time-domain spectroscopy imaging technique is possible to be used for the diagnosis of melanoma.
Collapse
Affiliation(s)
- Dandan Li
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Chongqing University, Chongqing 400044, China; Chongqing Engineering Research Center of High-Resolution and Three-Dimensional Dynamic Imaging Technology & Research Center of Applied Physics, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
| | - Zhongbo Yang
- Chongqing Engineering Research Center of High-Resolution and Three-Dimensional Dynamic Imaging Technology & Research Center of Applied Physics, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
| | - Ailing Fu
- School of Pharmaceutical Sciences, Southwest University, Chongqing 400715, China
| | - Tunan Chen
- Department of Neurosurgery, Southwest Hospital, Army Medical University, Chongqing 400038, China
| | - Ligang Chen
- Chongqing Engineering Research Center of High-Resolution and Three-Dimensional Dynamic Imaging Technology & Research Center of Applied Physics, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China; School of Pharmaceutical Sciences, Southwest University, Chongqing 400715, China
| | - Mingjie Tang
- Chongqing Engineering Research Center of High-Resolution and Three-Dimensional Dynamic Imaging Technology & Research Center of Applied Physics, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
| | - Hua Zhang
- Chongqing Engineering Research Center of High-Resolution and Three-Dimensional Dynamic Imaging Technology & Research Center of Applied Physics, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
| | - Ning Mu
- Department of Neurosurgery, Southwest Hospital, Army Medical University, Chongqing 400038, China
| | - Shi Wang
- Department of Neurosurgery, Southwest Hospital, Army Medical University, Chongqing 400038, China
| | - Guizhao Liang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Chongqing University, Chongqing 400044, China.
| | - Huabin Wang
- Chongqing Engineering Research Center of High-Resolution and Three-Dimensional Dynamic Imaging Technology & Research Center of Applied Physics, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China.
| |
Collapse
|
17
|
Genina EA, Bashkatov AN, Tuchina DK, Dyachenko (Timoshina) PA, Navolokin N, Shirokov A, Khorovodov A, Terskov A, Klimova M, Mamedova A, Blokhina I, Agranovich I, Zinchenko E, Semyachkina-Glushkovskaya OV, Tuchin VV. Optical properties of brain tissues at the different stages of glioma development in rats: pilot study. BIOMEDICAL OPTICS EXPRESS 2019; 10:5182-5197. [PMID: 31646040 PMCID: PMC6788608 DOI: 10.1364/boe.10.005182] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 09/04/2019] [Accepted: 09/06/2019] [Indexed: 05/03/2023]
Abstract
In this paper, measurements of the optical properties (diffuse reflectance, total and collimated transmittance) of brain tissues in healthy rats and rats with C6-glioma were performed in the spectral range from 350 to 1800 nm. Using these measurements, characteristic tissue optical parameters, such as absorption coefficient, scattering coefficient, reduced scattering coefficient, and scattering anisotropy factor were reconstructed. It was obtained that the 10-day development of glioma led to increase of absorption coefficient, which was associated with the water content elevation in the tumor. However, further development of the tumor (formation of the necrotic core) led to decrease in the water content. The dependence of the scattering properties on the different stages of model glioma development was more complex. Light penetration depth into the healthy and tumor brain was evaluated.
Collapse
Affiliation(s)
- Elina A. Genina
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
- Tomsk State University, 36 Lenin Avenue, Tomsk 634050, Russia
| | - Alexey N. Bashkatov
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
- Tomsk State University, 36 Lenin Avenue, Tomsk 634050, Russia
| | - Daria K. Tuchina
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
- Tomsk State University, 36 Lenin Avenue, Tomsk 634050, Russia
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilova str., Moscow 119991, Russia
| | - Polina A. Dyachenko (Timoshina)
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
- Tomsk State University, 36 Lenin Avenue, Tomsk 634050, Russia
| | - Nikita Navolokin
- Saratov State Medical University, 112, B. Kazachya str., Saratov 410012, Russia
| | - Alexander Shirokov
- Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, IBPPM RAS, 13 Prospekt Entuziastov, Saratov 410049, Russia
| | | | - Andrey Terskov
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
| | - Maria Klimova
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
| | - Aysel Mamedova
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
| | - Inna Blokhina
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
| | - Ilana Agranovich
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
| | | | | | - Valery V. Tuchin
- Saratov State University, 83 Astrakhanskaya Str., Saratov 410012, Russia
- Tomsk State University, 36 Lenin Avenue, Tomsk 634050, Russia
- Institute of Precision Mechanics and Control of the Russian Academy of Sciences, 24, Rabochaya Str., Saratov 410028, Russia
| |
Collapse
|
18
|
Wu L, Xu D, Wang Y, Liao B, Jiang Z, Zhao L, Sun Z, Wu N, Chen T, Feng H, Yao J. Study of in vivo brain glioma in a mouse model using continuous-wave terahertz reflection imaging. BIOMEDICAL OPTICS EXPRESS 2019; 10:3953-3962. [PMID: 31452987 PMCID: PMC6701535 DOI: 10.1364/boe.10.003953] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Revised: 06/29/2019] [Accepted: 06/29/2019] [Indexed: 05/21/2023]
Abstract
We demonstrated that in vivo brain glioma in a mouse model using a continuous-wave terahertz reflection imaging system, as well as the ex vivo fresh brain tissues in mouse model. The tumor regions of in vivo and ex vivo brain tissues can be well distinguished by THz intensity imaging at the frequency of 2.52THz. The THz images with high sensitivity correlated well with magnetic resonance, visual and hematoxylin and eosin stained images. Furthermore, the THz spectral difference between brain gliomas and normal brain tissues were obtained in the 0.6THz to 2.8THz range, where brain gliomas have the higher refractive indices and absorption coefficients, and their differences increase particularly in the high frequency range. These results suggest that THz imaging has great potential as an alternative method for the intraoperative label-free diagnosis of brain glioma in vivo.
Collapse
Affiliation(s)
- Limin Wu
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Degang Xu
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Yuye Wang
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Bin Liao
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Zhinan Jiang
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Lu Zhao
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Zhongcheng Sun
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| | - Nan Wu
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Tunan Chen
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Hua Feng
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China
| | - Jianquan Yao
- Institute of Laser and Optoelectronics, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Key Laboratory of Optoelectronic Information Science and Technology (Ministry of Education), Tianjin University, Tianjin 300072, China
| |
Collapse
|