1
|
Brain cytochrome-c-oxidase as a marker of mitochondrial function: A pilot study in major depression using NIRS. Depress Anxiety 2019; 36:766-779. [PMID: 31111623 PMCID: PMC6716511 DOI: 10.1002/da.22913] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2018] [Revised: 03/12/2019] [Accepted: 04/22/2019] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Brain mitochondrial dysfunction is implicated in the pathophysiology of mood disorders. Brain cytochrome-c-oxidase (COX) activity is associated with the mitochondrial function. Near-infrared spectroscopy (NIRS) noninvasively measures oxidized COX (oxCOX) and tissue oxygenation index (TOI) reflecting cerebral blood flow and oxygenation. METHODS oxCOX and TOI were assessed in prefrontal cortex (Fp1/2, Brodmann area 10) in patients in a major depressive episode (N = 13) with major depressive disorder (MDD; N = 7) and bipolar disorder (BD; N = 6) compared with the controls (N = 10). One patient with MDD and all the patients with BD were taking medications. Computational modeling estimated oxCOX and TOI related indices of mitochondrial function and cerebral blood flow, respectively. RESULTS oxCOX was lower in patients than controls (p = .014) correlating inversely with depression severity (r = -.72; p = .006), driven primarily by lower oxCOX in BD compared with the controls. Computationally modeled mitochondrial parameters of the electron transport chain, such as the nicotinamide adenine dinucleotide ratio (NAD+ /NADH; p = .001) and the proton leak rate across the inner mitochondrial membrane (klk2 ; p = .008), were also lower in patients and correlated inversely with depression severity. No such effects were found for TOI. CONCLUSIONS In this pilot study, oxCOX and related mitochondrial parameters assessed by NIRS indicate an abnormal cerebral metabolic state in mood disorders proportional to depression severity, potentially providing a biomarker of antidepressant effect. Because the effect was driven by the medicated BD group, findings need to be evaluated in a larger, medication-free population.
Collapse
|
2
|
Test-retest reliability of brain mitochondrial cytochrome-c-oxidase assessed by functional near-infrared spectroscopy. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-9. [PMID: 29766685 DOI: 10.1117/1.jbo.23.5.056006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Accepted: 04/24/2018] [Indexed: 05/10/2023]
Abstract
Functional near-infrared spectroscopy (fNIRS) is a noninvasive method for measuring in vivo both hemodynamic and mitochondrial metabolic activities in brain cortical structures. Although the test-retest reliability of the hemodynamic measures, such as reflected by oxygenated (HbO2), deoxygenated (HHb) hemoglobin, and the tissue oxygenation index (TOI), has been previously reported to be good to excellent, the reliability of the metabolic signal indexed by oxidized cytochrome-c-oxidase (oxCCO) has not been reported. The present test-retest study compared the reliability of the metabolic and hemodynamic signals in 10 healthy participants undergoing hypo- and hypercapnia challenges. The primary reliability measure was the intraclass correlation coefficient (ICC). Results of both hypo- and hypercapnia showed that the oxCCO signal (ICC = 0.876 / 0.757) had robust reliability comparable with that of the HbO2 (ICC = 0.841 / 0.801), HHb (ICC = 0.804 / 0.571), and TOI (ICC = 0.574 / 0.614) signals. These findings show that the oxCCO signal can be assessed by fNIRS with comparable reliability to the hemodynamic measures. We discuss the results in light of current interest in a mitochondrial metabolic marker derived from fNIRS.
Collapse
|
3
|
Multi-channel multi-distance broadband near-infrared spectroscopy system to measure the spatial response of cellular oxygen metabolism and tissue oxygenation. BIOMEDICAL OPTICS EXPRESS 2016; 7:4424-4440. [PMID: 27895985 PMCID: PMC5119585 DOI: 10.1364/boe.7.004424] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 09/22/2016] [Accepted: 09/26/2016] [Indexed: 05/22/2023]
Abstract
We present a multi-channel, multi-distance broadband near-infrared spectroscopy (NIRS) system with the capability of measuring changes in haemoglobin concentrations (Δ[HbO2], Δ[HHb]), oxidation state of cytochrome-c-oxidase (Δ[oxCCO]) and tissue oxygen saturation (TOI) in the adult human brain. The main components of the instrument are two customized spectrographs and two light sources. Each spectrograph is lens-based to improve light throughput, has a grating enhanced to optimise reflection in the near-infrared (NIR) spectral region and uses a front illuminated cooled CCD camera (-70° C) with a square chip dimension of 12.3 x 12.3 mm (512 x 512 pixels). Each light source uses a 50W halogen bulb with a gold plated mirror to increase the intensity of the NIR light. Each light source was connected to a custom-built bifurcated fibre bundle to create two source fibre bundles (3.2 mm diameter each). Each spectrograph received light input from another custom-built fibre bundle comprised of six individual bundles (one with 0.6 mm diameter and the other five with 1.5 mm diameter). All fibre bundles were fixed on a 3D printed optode holder (two light sources x two fibre bundles each = four probes; and two spectrographs x six fibre bundles each = 12 probes) that allowed 24 multi-distance channels across the forehead (six channels at 20 mm, three channels at 30 mm and 15 channels at 35 mm) and six TOI measurements. We demonstrated the use of the system in a cohort of nine healthy adult volunteers during prefrontal cortex functional activation using the Stroop task. We have observed functional responses identified as significant increase in Δ[HbO2], decrease in Δ[HHb] and increase in Δ[oxCCO] in five channels (out of 12), that overlay the left and right dorsolateral prefrontal cortices. There was no observable TOI functional response and we have shown small variations in TOI across different sites within the same subject and within the same site across subjects.
Collapse
|
4
|
Submaximal exercise testing with near-infrared spectroscopy in Myalgic Encephalomyelitis/Chronic Fatigue Syndrome patients compared to healthy controls: a case-control study. J Transl Med 2015; 13:159. [PMID: 25990639 PMCID: PMC4438583 DOI: 10.1186/s12967-015-0527-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 05/09/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) is a debilitating illness. Symptoms include profound fatigue and distinctive post-exertional malaise (PEM). We asked whether a submaximal exercise test would prove useful for identifying different patterns of tissue oxygen utilization in individuals with ME/CFS versus healthy subjects. Such a test has potential to aid with ME/CFS diagnosis, or to characterize patients' illness. METHODS A case-control study of 16 patients with ME/CFS compared to 16 healthy controls completing a 3-min handgrip protocol was performed. Response was measured using near-infrared spectroscopy, resulting in measurements of oxygenated (O2Hb) and deoxygenated hemoglobin (HHb) over wrist extensors and flexors. Changes in O2Hb (delta (d)O2Hb) and HHb (dHHb) absorbance between the first and last contraction were calculated, as were the force-time product of all contractions, measured as tension-time index (TTI), and ratings of perceived exertion (RPE). RESULTS Individuals with ME/CFS demonstrated smaller dO2Hb and dHHb than controls. However, after adjusting for TTI and change in total hemoglobin (delta (d)tHb), differences in dO2Hb and dHHb were reduced, with large overlapping variances. RPE was significantly higher for cases than controls, particularly at rest. CONCLUSIONS Relative to controls, participants with ME/CFS demonstrated higher RPE, lower TTI, and reduced dO2Hb and dHHb during repetitive handgrip exercise, although considerable variance was observed. With further study, submaximal exercise testing may prove useful for stratifying patients with a lower propensity for inducing PEM, and have the ability to establish baseline intensities for exercise prescription.
Collapse
|
5
|
Optimal wavelength combinations for near-infrared spectroscopic monitoring of changes in brain tissue hemoglobin and cytochrome c oxidase concentrations. BIOMEDICAL OPTICS EXPRESS 2015; 6:933-47. [PMID: 25798316 PMCID: PMC4361446 DOI: 10.1364/boe.6.000933] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Revised: 02/09/2015] [Accepted: 02/11/2015] [Indexed: 05/19/2023]
Abstract
We analyze broadband near-infrared spectroscopic measurements obtained from newborn piglets subjected to hypoxia-ischemia and we aim to identify optimal wavelength combinations for monitoring cerebral tissue chromophores. We implement an optimization routine based on the genetic algorithm to perform a heuristic search for discrete wavelength combinations that can provide accurate concentration information when benchmarked against the gold standard of 121 wavelengths. The results indicate that it is possible to significantly reduce the number of measurement wavelengths used in conjunction with spectroscopic algorithms and still achieve a high performance in estimating changes in concentrations of oxyhemoglobin, deoxyhemoglobin, and oxidized cytochrome c oxidase. While the use of a 3-wavelength combination leads to mean recovery errors of up to 10%, these errors drop to less than 4% with 4 or 5 wavelengths and to even less than 2% with 8 wavelengths.
Collapse
|
6
|
A new broadband near-infrared spectroscopy system for in-vivo measurements of cerebral cytochrome-c-oxidase changes in neonatal brain injury. BIOMEDICAL OPTICS EXPRESS 2014; 5:3450-66. [PMID: 25360364 PMCID: PMC4206316 DOI: 10.1364/boe.5.003450] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 08/15/2014] [Accepted: 08/22/2014] [Indexed: 05/02/2023]
Abstract
We present a novel lens-based broadband near-infrared spectroscopy system to simultaneously measure cerebral changes in tissue oxygenation and haemodynamics via estimation of the changes in haemoglobin concentration; in addition to oxygen utilization via the measurement of the oxidation state of cytochrome-c-oxidase (CCO). We demonstrate the use of the system in a cohort of 6 newborn infants with neonatal encephalopathy in the Neonatal Intensive Care Unit for continuous measurement periods of up to 5 days. NIRS data was collected from above the frontal lobe on the left and right hemispheres simultaneously with systemic data to allow multimodal data analysis. This allowed us to study the NIRS variables in response to global pathophysiological events and we focused our analysis to spontaneous oxygen desaturations. We identified changes from the NIRS variables during 236 oxygen desaturations from over 212 hours of data with a change from the baseline to nadir of -12 ± 3%. There was a consistent negative change in the Δ[HbD] (= oxygenated - deoxygenated haemoglobin) and Δ[oxCCO] measurements, mean decreases were 3.0 ± 1.7μM and 0.22 ± 0.11μM, and a positive change in the Δ[HbT] (= oxygenated + deoxygenated haemoglobin) measurements across all subjects, mean increase was 0.85 ± 0.58μM. We have shown with a feasibility study that the relationship between haemoglobin oxygenation changes and CCO oxidation changes during these desaturation events was significantly associated with a magnetic resonance spectroscopy (MRS)-measured biomarker of injury severity (r = 0.91, p<0.01).
Collapse
|
7
|
Systematic investigation of changes in oxidized cerebral cytochrome c oxidase concentration during frontal lobe activation in healthy adults. BIOMEDICAL OPTICS EXPRESS 2012; 3:2550-66. [PMID: 23082295 PMCID: PMC3469997 DOI: 10.1364/boe.3.002550] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2012] [Revised: 05/10/2012] [Accepted: 06/30/2012] [Indexed: 05/02/2023]
Abstract
Using transcranial near-infrared spectroscopy (NIRS) to measure changes in the redox state of cerebral cytochrome c oxidase (Δ[oxCCO]) during functional activation in healthy adults is hampered by instrumentation and algorithm issues. This study reports the Δ[oxCCO] response measured in such a setting and investigates possible confounders of this measurement. Continuous frontal lobe NIRS measurements were collected from 11 healthy volunteers during a 6-minute anagram-solving task, using a hybrid optical spectrometer (pHOS) that combines multi-distance frequency and broadband components. Only data sets showing a hemodynamic response consistent with functional activation were interrogated for a Δ[oxCCO] response. Simultaneous systemic monitoring data were also available. Possible influences on the Δ[oxCCO] response were systematically investigated and there was no effect of: 1) wavelength range chosen for fitting the measured attenuation spectra; 2) constant or measured, with the pHOS in real-time, differential pathlength factor; 3) systemic hemodynamic changes during functional activation; 4) changes in optical scattering during functional activation. The Δ[oxCCO] response measured in the presence of functional activation was heterogeneous, with the majority of subjects showing significant increase in oxidation, but others having a decrease. We conclude that the heterogeneity in the Δ[oxCCO] response is physiological and not induced by confounding factors in the measurements.
Collapse
|
8
|
Hemodynamic and oxidative mechanisms of tourniquet-induced muscle injury: near-infrared spectroscopy for the orthopedics setting. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:081408-1. [PMID: 23224169 DOI: 10.1117/1.jbo.17.8.081408] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
During orthopedic procedures, the tourniquets used to maintain bloodless surgical fields cause ischemia and then reperfusion (I/R), leading to oxidative muscle injury. Established methods exist neither for monitoring orthopedic I/R nor for predicting the extent of tourniquet-associated oxidative injury. To develop a predictive model for tourniquet-associated oxidative muscle injury, this study combined real-time near-infrared spectroscopy (NIRS) monitoring of I/R with Western blotting (WB) for oxidized proteins. We hypothesized strong correlations between NIRS-derived I/R indices and muscle protein oxidation. In 17 patients undergoing ankle fracture repair, a thigh tourniquet was inflated on the injured limb (300 mmHg). Using a continuous-wave (CW) NIRS setup, oxygenated (O2Hb), deoxygenated (HHb), and total (tHb) hemoglobin were monitored bilaterally (tourniquet versus control) in leg muscles. Leg muscle biopsies were collected unilaterally (tourniquet side) immediately after tourniquet inflation (pre) and before deflation (post). Average ischemia duration was 43.2 ± 14.6 min. In post-compared to pre-biopsies, muscle protein oxidation (quantified using WB) increased 172.3%± 145.7% (P<0.0005). Changes in O2Hb and tHb were negatively correlated with protein oxidation (respectively: P=0.040, R2=0.25 and P=0.003, R2=0.58). Reoxygenation rate was positively correlated with protein oxidation (P=0.041, R2=0.25). These data indicate that using CW NIRS, it is possible to predict orthopedic tourniquet-associated muscle oxidative injury noninvasively.
Collapse
|
9
|
Modelling noninvasively measured cerebral signals during a hypoxemia challenge: steps towards individualised modelling. PLoS One 2012; 7:e38297. [PMID: 22679497 PMCID: PMC3367969 DOI: 10.1371/journal.pone.0038297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2012] [Accepted: 05/02/2012] [Indexed: 11/21/2022] Open
Abstract
Noninvasive approaches to measuring cerebral circulation and metabolism are crucial to furthering our understanding of brain function. These approaches also have considerable potential for clinical use “at the bedside”. However, a highly nontrivial task and precondition if such methods are to be used routinely is the robust physiological interpretation of the data. In this paper, we explore the ability of a previously developed model of brain circulation and metabolism to explain and predict quantitatively the responses of physiological signals. The five signals all noninvasively-measured during hypoxemia in healthy volunteers include four signals measured using near-infrared spectroscopy along with middle cerebral artery blood flow measured using transcranial Doppler flowmetry. We show that optimising the model using partial data from an individual can increase its predictive power thus aiding the interpretation of NIRS signals in individuals. At the same time such optimisation can also help refine model parametrisation and provide confidence intervals on model parameters. Discrepancies between model and data which persist despite model optimisation are used to flag up important questions concerning the underlying physiology, and the reliability and physiological meaning of the signals.
Collapse
|
10
|
Haemoglobin oxygen saturation as a biomarker: the problem and a solution. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2011; 369:4407-24. [PMID: 22006898 PMCID: PMC3263786 DOI: 10.1098/rsta.2011.0250] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Near-infrared spectroscopy measures of haemoglobin oxygen saturation are often used as an indicator of sufficient oxygen delivery to assess injury susceptibility and tissue damage. They have also often been used as a surrogate measure of oxygen metabolism. Unfortunately, these measures have generally failed to provide robust indicators of injury and metabolism. In this paper, we first review when haemoglobin oxygen saturation does work as a robust indicator, and then detail when and why it fails for assessing brain injury and breast cancer. Finally, we discuss the solution to obtain more robust measures of tissue injury and cancer by combining oxygen saturation measurements with measures of blood flow and volume to more accurately estimate oxygen metabolism.
Collapse
|
11
|
Sternocleidomastoid muscle deoxygenation in response to incremental inspiratory threshold loading measured by near infrared spectroscopy. Respir Physiol Neurobiol 2011; 178:202-9. [DOI: 10.1016/j.resp.2011.06.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2010] [Revised: 05/31/2011] [Accepted: 06/03/2011] [Indexed: 10/18/2022]
|
12
|
Bicuculline-induced seizures: a challenge for optical and biochemical modeling of the cytochrome oxidase CuA NIRS signal. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2009. [PMID: 19227461 DOI: 10.1007/978-0-387-85998-9_20] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register]
Abstract
The effect of seizures on brain blood flow and metabolism has been extensively studied. However, few studies have focused on mitochondria. We used near infrared spectroscopy (NIRS) to study hemoglobin and cytochrome oxidase changes during seizures, induced by the GABA antagonist bicuculline, in the adult rat. A broadband spectroscopy system was used with the optodes placed across the rat head. We focused on the initial seizures post-bicuculline addition during which oxyhemoglobin (HbO2) increased, deoxyhemoglobin (HHb) decreased and total hemoglobin (Hbtot) increased. The NIRS signal associated with the oxidised CuA centre of mitochondrial cytochrome c oxidase (oxCCO) decreased. At the highest bicuculline doses (0.25 mg/animal) the maximum values recorded were: delta HbO2 = +19 +/- 7 microM; delta HHb = -12 +/- 4 microM; delta Hbtot = +7 +/- 4 microM, delta oxCCO = - 1.7 +/- 0.3 microM. These results are broadly in line with other NIRS studies. However, previous measurements of NADH fluorescence indicate oxidation of the mitochondrial redox chain under these conditions. The changes induced by bicuculline provide an interesting challenge to the physics and biochemistry of using NIRS to study mitochondrial redox states in vivo and we explore the possible spectroscopic and/or biochemical meaning of these apparent anomalies.
Collapse
|
13
|
Relationship Between Brain Tissue Haemodynamics, Oxygenation And Metabolism In The Healthy Human Adult Brain During Hyperoxia And Hypercapnea. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2008; 645:315-20. [DOI: 10.1007/978-0-387-85998-9_47] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
|
14
|
A model of brain circulation and metabolism: NIRS signal changes during physiological challenges. PLoS Comput Biol 2008; 4:e1000212. [PMID: 18989392 PMCID: PMC2573000 DOI: 10.1371/journal.pcbi.1000212] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2008] [Accepted: 09/23/2008] [Indexed: 11/19/2022] Open
Abstract
We construct a model of brain circulation and energy metabolism. The model is designed to explain experimental data and predict the response of the circulation and metabolism to a variety of stimuli, in particular, changes in arterial blood pressure, CO(2) levels, O(2) levels, and functional activation. Significant model outputs are predictions about blood flow, metabolic rate, and quantities measurable noninvasively using near-infrared spectroscopy (NIRS), including cerebral blood volume and oxygenation and the redox state of the Cu(A) centre in cytochrome c oxidase. These quantities are now frequently measured in clinical settings; however the relationship between the measurements and the underlying physiological events is in general complex. We anticipate that the model will play an important role in helping to understand the NIRS signals, in particular, the cytochrome signal, which has been hard to interpret. A range of model simulations are presented, and model outputs are compared to published data obtained from both in vivo and in vitro settings. The comparisons are encouraging, showing that the model is able to reproduce observed behaviour in response to various stimuli.
Collapse
|
15
|
Increase in cerebral aerobic metabolism by normobaric hyperoxia after traumatic brain injury. J Neurosurg 2008; 109:424-32. [PMID: 18759572 DOI: 10.3171/jns/2008/109/9/0424] [Citation(s) in RCA: 78] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Traumatic brain injury (TBI) is associated with depressed aerobic metabolism and mitochondrial dysfunction. Normobaric hyperoxia (NBH) has been suggested as a treatment for TBI, but studies in humans have produced equivocal results. In this study the authors used brain tissue O(2) tension measurement, cerebral microdialysis, and near-infrared spectroscopy to study the effects of NBH after TBI. They investigated the effects on cellular and mitochondrial redox states measured by the brain tissue lactate/pyruvate ratio (LPR) and the change in oxidized cytochrome c oxidase (CCO) concentration, respectively. METHODS The authors studied 8 adults with TBI within the first 48 hours postinjury. Inspired oxygen percentage at normobaric pressure was increased from baseline to 60% for 60 minutes and then to 100% for 60 minutes before being returned to baseline for 30 minutes. RESULTS The results are presented as the median with the interquartile range in parentheses. During the 100% inspired oxygen percentage phase, brain tissue O2 tension increased by 7.2 kPa (range 4.5-9.6 kPa) (p < 0.0001), microdialysate lactate concentration decreased by 0.26 mmol/L (range 0.0-0.45 mmol/L) (p = 0.01), microdialysate LPR decreased by 1.6 (range 1.0-2.3) (p = 0.02), and change in oxidized CCO concentration increased by 0.21 mumol/L (0.13-0.38 micromol/L) (p = 0.0003). There were no significant changes in intracranial pressure or arterial or microdialysate glucose concentration. The change in oxidized CCO concentration correlated with changes in brain tissue O(2) tension (r(s)= 0.57, p = 0.005) and in LPR (r(s)= -0.53, p = 0.006). CONCLUSIONS The authors have demonstrated oxidation in cerebral cellular and mitochondrial redox states during NBH in adults with TBI. These findings are consistent with increased aerobic metabolism and suggest that NBH has the potential to improve outcome after TBI. Further studies are warranted.
Collapse
|
16
|
Simultaneous measurement of changes in light absorption due to the reduction of cytochrome c oxidase and light scattering in rat brains during loss of tissue viability. APPLIED OPTICS 2008; 47:4164-76. [PMID: 18670575 DOI: 10.1364/ao.47.004164] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
We performed the simultaneous measurement of intrinsic optical signals (IOSs) related to metabolic activity and cellular and subcellular morphological characteristics, i.e., light scattering for a rat global ischemic brain model made by rapidly removing blood by saline infusion. The signals were measured on the basis of multiwavelength diffuse reflectances in which 605 and 830 nm were used to detect the IOSs that are thought to be dominantly affected by redox changes of heme aa(3) and CuA in cytochrome c oxidase (CcO), respectively. For measuring the scattering signal, the wavelength that was found to be most insensitive to the absorption changes, e.g., approximately 620 nm, was used. The measurements suggested that an increase in the absorption due to reduction of heme aa(3) occurred soon after blood clearance, and this was followed by a large triphasic change in light scattering, during which time a decrease in the absorption due to reduction of CuA occurred. Through the triphasic scattering change, scattering signals increased by 5.2 +/- 1.5% (n = 5), and the increase in light scattering showed significant correlation with both the reflectance intensity changes at 605 and 830 nm. This suggests that morphological changes in cells correlate with reductions of heme aa(3) and CuA. Histological analysis of tissue after the triphasic scattering change showed no alteration in either the nuclei or the cytoskeleton, but electron microscopic observation revealed deformed, enlarged mitochondria and expanded dendrites. These findings suggest that the simultaneous measurement of absorption signals related to the redox changes in the CcO and the scattering signal is useful for monitoring tissue viability in the brain.
Collapse
|
17
|
The targeted behavior of thermally responsive nanohydrogel evaluated by NIR system in mouse model. J Control Release 2008; 131:34-40. [PMID: 18691619 DOI: 10.1016/j.jconrel.2008.07.019] [Citation(s) in RCA: 78] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2008] [Revised: 06/26/2008] [Accepted: 07/11/2008] [Indexed: 10/21/2022]
Abstract
Thermally responsive poly(N-isopropylacrylamide-co-acrylamide) (P(NIPA-co-AAm)) nanohydrogels were synthesized in this study by free-radical precipitation polymerization method. Different lower critical solution temperatures (LCST) of nanohydrogels were obtained by modulating the amount of AAm and characterized by measuring their transmittances of the particle solutions at 500 nm. The diameters within the range of 50-450 nm were achieved by manipulating the amount of sodiumdodecyl sulfate (SDS). Near infrared dye NIRD-12, with excitation and emission wavelengths at 772 nm and 814 nm, was entrapped into the P(NIPA-co-AAm) nanohydrogels for in vivo animal study. The thermally targeted behavior of the nanohydrogels was evaluated by the in vivo fluorescence imaging on different groups of denuded mice, with or without S180 tumors and with or without hyperthermia treatment. Results indicated that this kind of thermally responsive nanohydrogel could only accumulate in the tissue with higher temperature, no matter normal tissue and tumor site. The thermally targeted behavior is passive and non-specific. The targeted location can be selected by hyperthermia treatment and manipulating the suitable LCST of nanohydrogel. Results indicated that the thermally responsive P(NIPA-co-AAm) nanohydrogel could be used as an attracting thermally targeted carrier for drugs, especially for anti-cancer drugs.
Collapse
|
18
|
In vivo non-invasive optical imaging of temperature-sensitive co-polymeric nanohydrogel. NANOTECHNOLOGY 2008; 19:185707. [PMID: 21825703 DOI: 10.1088/0957-4484/19/18/185707] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Assessment of hyperthermia in pathological tissue is a promising strategy for earlier diagnosis of malignant tumors. In this study, temperature-sensitive co-polymeric nanohydrogel poly(N-isopropylacrylamide-co-acrylic acid) (PNIPA-co-AA) was successfully synthesized by the precipitation polymerization method. The diameters of nanohydrogels were controlled to be less than 100 nm. Also the lower critical solution temperature (LCST, 40 °C) was manipulated above physiological temperature after integration of near-infrared (NIR) organic dye (heptamethine cyanine dye, HMCD) within its interior cores. NIR laser light (765 nm), together with sensitive charge coupled device (CCD) cameras, were designed to construct an NIR imaging system. The dynamic behaviors of PNIPA-co-AA-HMCD composites in denuded mice with or without local hyperthermia treatment were real-time monitored by an NIR imager. The results showed that the PNIPA-co-AA-HMCD composites accumulated in the leg treated with local heating and diffused much slower than that in the other leg without heating. The results demonstrated that the temperature-responsive PNIPA-co-AA-HMCD composites combining with an NIR imaging system could be an effective temperature mapping technique, which provides a promising prospect for earlier tumor diagnosis and thermally related therapeutic assessment.
Collapse
|
19
|
Brain oxymetry in the operating room: current status and future directions with particular regard to cytochrome oxidase. JOURNAL OF BIOMEDICAL OPTICS 2008; 13:033001. [PMID: 18601545 DOI: 10.1117/1.2940583] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Near-infrared spectroscopy (NIRS) is a cerebral monitoring method that noninvasively and continuously measures cerebral hemoglobin oxygenation and the redox state of cytochrome oxidase using highly tissue-permeable near-infrared light. This technique now has wide clinical application, and its usefulness in the measurement of cerebral hemoglobin oxygenation has been confirmed under global cerebral injury and/or hypoxemic hypoxia; however, regional cerebral infarction located far from the monitoring site may not be detected by NIRS. Furthermore, the specificity and accuracy of the measurement of the redox state of cytochrome oxidase remain controversial. We apply NIRS to both animal and clinical investigations. Based on these results, we discuss the significance of the measurement of cerebral hemoglobin oxygenation and cytochrome oxidase in vivo and in clinical medicine. Using our algorithm, cytochrome oxidase signals are unaffected by hemoglobin signals, even when hematocrit values change from 35 to 5% under cardiopulmonary bypass in a dog model. In the clinical study, cytochrome oxidase during surgery is likely to be a good (though not perfect) predictor of postoperative cerebral outcome. NIRS appears to be a promising technology, but additional investigations are required to establish its clinical efficacy and justify its routine use during operative and perioperative periods.
Collapse
|
20
|
Non-invasive near infrared fluorescence imaging of CdHgTe quantum dots in mouse model. J Fluoresc 2008; 18:801-11. [PMID: 18176780 DOI: 10.1007/s10895-007-0307-9] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2007] [Accepted: 12/06/2007] [Indexed: 01/09/2023]
Abstract
Near infrared CdHgTe quantum dots (QDs) acted as biomarker for in vivo imaging were synthesized in aqueous solution. The size and the fluorescence wavelength of the synthesized quantum dots can be arbitrary manipulated by using different refluxing time. In particular, the fluorescence wavelength was extended to near infrared range (700 approximately 900 nm), which make the in vivo imaging possible. Meanwhile, the characteristics, such as morphology, size, spectra, stability and toxicity were investigated. The dynamic bio-distribution, clearance from blood, liver and intestine in living animal were in vivo monitored by a NIR imaging system. The circulation of CdHgTe QDs in living mice was addressed semi-quantitatively according to the changes of fluorescence intensity. The high stability as well as high fluorescence intensity makes QDs particular interested candidates for in vivo imaging studies.
Collapse
|