1
|
Alhorani Q, Al-Ibraheem A, Rawashdeh M, Alkhybari E, Sabarudin A, A. Latiff R, Mohamad M. Investigating knowledge of DRLs, image quality and radiation dose in PET/CT and CT imaging among medical imaging professionals. Heliyon 2024; 10:e30030. [PMID: 38707442 PMCID: PMC11066384 DOI: 10.1016/j.heliyon.2024.e30030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 04/13/2024] [Accepted: 04/18/2024] [Indexed: 05/07/2024] Open
Abstract
Objective To investigate the knowledge of diagnostic reference levels (DRLs), image quality, radiation dose and protocol parameters among Jordanian medical imaging professionals (MIPs) involved in PET/CT and CT scan procedures. Materials and methods A questionnaire was designed and distributed to MIPs in Jordan. The survey comprised four sections: demographic data, MIP knowledge on dose/protocol parameters, image quality, and DRLs. Statistical analyses were performed utilizing Pearson's correlation, t-tests, ANOVA, and linear regression, with a significance level of 95 % and a p-value threshold of <0.05. Results The study involved 147 participants. Most respondents were male (76.2 %), and most were aged 26-35 years (44.2 %). Approximately 51 % held a bachelor's degree, and the most common range of experience was 3-5 years (28.6 %). Participants showed a moderate level of knowledge regarding dose and protocol parameters, with a mean score of 61.8 %. The mean scores for knowledge of image quality and DRLs were 45.2 % and 44.8 %, respectively. The age group of the MIPs and the total experience were found to have a significant impact on the knowledge of the dose and protocol parameters, as well as the DRLs. Additionally, experience was found to have a significant influence on knowledge of the dose and protocol parameters. The study revealed a positive and significant effect of MIPs' knowledge of dose/protocol parameters and image quality on their knowledge of DRLs. Conclusions This study indicates that professionals across five specialties who are engaged in PET/CT and CT imaging possess a moderate understanding of dosage and protocol parameters. However, there is a notable gap in knowledge regarding DRLs and image quality. To address this issue, it is recommended that MIPs actively engage in educational programs emphasizing exposure parameters and their impact on image quality. Additionally, access to comprehensive education and training programs will enable MIPs to grasp the complexities of DRLs and their implications, facilitating their implementation in clinical practice.
Collapse
Affiliation(s)
- Qays Alhorani
- Diagnostic Imaging & Radiotherapy Program, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| | - Akram Al-Ibraheem
- Department of Nuclear Medicine, King Hussein Cancer Center, Amman, Jordan
| | - Mohammad Rawashdeh
- Radiologic Technology Program, Applied Medical Sciences College, Jordan University of Science and Technology, Irbid, Jordan
- Faculty of Health Sciences, Gulf Medical University, Ajman, United Arab Emirates
| | - Essam Alkhybari
- Department of Radiology and Medical Imaging, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Saudi Arabia
| | - Akmal Sabarudin
- Diagnostic Imaging & Radiotherapy Program, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| | - Rukiah A. Latiff
- Diagnostic Imaging & Radiotherapy Program, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| | - Mazlyfarina Mohamad
- Diagnostic Imaging & Radiotherapy Program, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| |
Collapse
|
2
|
Yang F, Gao L. Age-based diagnostic reference levels and achievable doses for paediatric CT: a survey in Shanghai, China. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2024; 44:021509. [PMID: 38599187 DOI: 10.1088/1361-6498/ad3ce5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 04/10/2024] [Indexed: 04/12/2024]
Abstract
Computed tomography (CT) is extensively utilised in medical diagnostics due to its notable radiographic superiority. However, the cancer risk associated with CT examinations, particularly in children, is of significant concern. The assessment of cancer risk relies on the radiation dose to examinees. Diagnostic reference levels (DRLs) and achievable doses (ADs) were used to assess the level of radiation dose in CT examinations widely. Although the national DRLs of paediatric CT have been explored in China, few local DRLs at the city level have been assessed. To set up the local DRLs and ADs of paediatric CT, we investigated the radiation dose level for paediatric CT in Shanghai. In this survey, a total of 3061 paediatric CT examinations underwent in Shanghai in 2022 were selected by stratified sampling, and the dose levels in terms of volume CT dose index (CTDIvol) and the dose-length product (DLP) were analysed by 4 age groups. The DRLs and ADs were set at the 75th and 50th percentile of the distribution and compared with the previous studies at home and abroad. The survey results revealed that, for head scan, the DRLs of CTDIvolwere from 25 to 46 mGy, and the levels of DLP were from 340 to 663 mGy·cm. For chest, the DRLs of CTDIvolwere from 2.2 to 8.3 mGy, and the levels of DLP were from 42 to 223 mGy·cm. For abdomen, the DRLs of CTDIvolwere from 6.3 to 16 mGy, and the levels of DLP were from 181 to 557 mGy·cm. The ADs were about 60% lower than their corresponding DRLs. The levels of radiation doses in children-based hospitals were higher than those in other medical institutions (P< 0.001). In conclusion, there was still potential for reducing radiation dose of paediatric CT, emphasising the urgent need for optimising paediatric CT dose in Shanghai.
Collapse
Affiliation(s)
- Fanqiaochu Yang
- School of Public Health, Fudan University, Shanghai, People's Republic of China
| | - Linfeng Gao
- Shanghai Municipal Center for Disease Control & Prevention, Shanghai, People's Republic of China
| |
Collapse
|
3
|
Alzyoud K, Al-Murshedi S, England A. Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review. HEALTH PHYSICS 2024; 126:156-162. [PMID: 38252949 DOI: 10.1097/hp.0000000000001778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2024]
Abstract
ABSTRACT A comprehensive search was performed to examine the literature on diagnostic reference levels (DRL) for computed tomography (CT) and radiography examinations that are performed routinely in Jordan. EBSCO, Scopus, and Web of Science were used for the search. The acronym "DRL" and the additional phrase "dose reference levels" were used to search for articles in literature. Seven papers that reported DRL values for radiography and CT scans in Jordan were identified. One study reported DRLs for conventional radiography, two studies reported CT DRLs in pediatrics, and the remaining four studies provided DRL values for adult CT scans. The most popular techniques for determining the DRLs were the entrance surface dose, volume CT dose index (CTDIvol), and dose-length product (DLP) values. Variations in Jordanian DRL values were noted across both modalities. Lower radiation doses and less variation in DRL values may be achieved by educating and training radiographers to better understand dose reduction strategies. To limit dose variance and enable dosage comparison, CT DRLs must be standardized in accordance with the guidelines of the International Commission on Radiological Protection (ICRP).
Collapse
Affiliation(s)
- Kholoud Alzyoud
- Department of Medical Imaging, Faculty of Applied Health science, The Hashemite University, P.O. Box 330127, Zarqa, 13133, Jordan
| | - Sadeq Al-Murshedi
- AL-Zahraa University for Women, College of Health and Medical Technology, Karbala, Iraq
| | | |
Collapse
|
4
|
Rawashdeh M, Bani Yaseen AB, McEntee M, England A, Kumar P, Saade C. Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2024; 32:725-734. [PMID: 38189739 DOI: 10.3233/xst-230276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2024]
Abstract
BACKGROUND To reduce radiation dose and subsequent risks, several legislative documents in different countries describe the need for Diagnostic Reference Levels (DRLs). Spinal radiography is a common and high-dose examination. Therefore, the aim of this work was to establish the DRL for Computed Tomography (CT) examinations of the spine in healthcare institutions across Jordan. METHODS Data was retrieved from the picture archiving and communications system (PACS), which included the CT Dose Index (CTDI (vol) ) and Dose Length Product (DLP). The median radiation dose values of the dosimetric indices were calculated for each site. DRL values were defined as the 75th percentile distribution of the median CTDI (vol) and DLP values. RESULTS Data was collected from 659 CT examinations (316 cervical spine and 343 lumbar-sacral spine). Of the participants, 68% were males, and the patients' mean weight was 69.7 kg (minimum = 60; maximum = 80, SD = 8.9). The 75th percentile for the DLP of cervical and LS-spine CT scans in Jordan were 565.2 and 967.7 mGy.cm, respectively. CONCLUSIONS This research demonstrates a wide range of variability in CTDI (vol) and DLP values for spinal CT examinations; these variations were associated with the acquisition protocol and highlight the need to optimize radiation dose in spinal CT examinations.
Collapse
Affiliation(s)
- Mohammad Rawashdeh
- Faculty of Health Sciences, Gulf Medical University, Ajman, UAE
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Abdel-Baset Bani Yaseen
- Faculty of Health, School of Clinical Science, Queensland University of Technology, Queensland, Australia
| | - Mark McEntee
- Discipline of Medical Imaging and Radiation Therapy, Brookfield Health Sciences, University College Cork, Cork, Ireland
| | - Andrew England
- Discipline of Medical Imaging and Radiation Therapy, Brookfield Health Sciences, University College Cork, Cork, Ireland
| | - Praveen Kumar
- Faculty of Health Sciences, Gulf Medical University, Ajman, UAE
| | - Charbel Saade
- Discipline of Medical Imaging and Radiation Therapy, Brookfield Health Sciences, University College Cork, Cork, Ireland
| |
Collapse
|
5
|
Benmessaoud M, Dadouch A, Maghnouj A, Lemmassi A, Tahiri M, El-Ouardi Y, Ait Ouaggou I. Establishment of local diagnostic reference levels for paediatric abdominal-pelvis and Chest-abdominal-pelvis computed tomography in Morocco: suggests the need for improved optimization efforts. RADIATION PROTECTION DOSIMETRY 2023:7160592. [PMID: 37177805 DOI: 10.1093/rpd/ncad149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 03/25/2023] [Accepted: 04/05/2023] [Indexed: 05/15/2023]
Abstract
The purpose of the current study was to derive the local diagnostic reference levels (LDRLs) for paediatric abdominal-pelvis (AP) and chest-abdominal-pelvis (CAP) computed tomography in Morocco. The data were gathered retrospectively from two hospitals for 6 months. The LDRLs were defined by volume CT dose index (CTDIvol), dose-length product (DLP) per sequence, DLP per procedure and size-specific dose estimates (SSDE). The SSDE assessment was based on the effective diameters of patients scanned. A total of 630 CT examinations were collected involving 324 AP and 306 CAP scans. The proposed LDRLs for AP, in terms of CTDIvol (mGy), were 6.9, 8.5, 8.5 and 8.5 for < 1, 1 to < 5, 5 to < 10 and 10 to < 15 y age groups, respectively. In terms of DLP (mGy.cm) per procedure, they were 436.3, 534.5, 687.9 and 961.7. In terms of SSDE (mGy), thet were 16.73, 16.83, 17.5 and 15.8 for < 1, 1 to < 5, 5 to < 10 and 10 to < 15 y, respectively. The corresponding LDRLs for CAP, in terms of CTDIvol (mGy), were 7.3, 7.3, 7.3 and 10.35. In terms of DLP (mGy.cm) per procedure, they were 531, 622.5, 705 and 936. In terms of SSDE (mGy), they were 16.22, 15.05, 14.47 and 15.2, respectively, for the four age groups. The derived dose levels were mostly higher than those found in other studies, which demonstrates the need for dose optimization and paediatric protocol standardization as well as the timeliness of the intent to establish not only local DRLs but national ones in the near future.
Collapse
Affiliation(s)
- Mounir Benmessaoud
- Sidi Mohamed Ben Abdellah University, Faculty of Sciences Dhar EL Mahraz, Fez, Morocco
| | - Ahmed Dadouch
- Sidi Mohamed Ben Abdellah University, Faculty of Sciences Dhar EL Mahraz, Fez, Morocco
| | - Abdelmajid Maghnouj
- Sidi Mohamed Ben Abdellah University, Faculty of Sciences Dhar EL Mahraz, Fez, Morocco
| | - Assiya Lemmassi
- Sidi Mohamed Ben Abdellah University, Higher School of Technology, Fez, Morocco
| | - Maroine Tahiri
- Hassan First University, Higher Institute of Health Sciences, Settat, Morocco
| | - Youssef El-Ouardi
- Sidi Mohamed Ben Abdellah University, Faculty of Sciences Dhar EL Mahraz, Fez, Morocco
| | - Ibrahim Ait Ouaggou
- University Mohammed First, National School of Applied Sciences, Oujda, Morocco
| |
Collapse
|
6
|
A new approach to dose reference levels in pediatric CT: Age and size-specific dose estimation. Radiat Phys Chem Oxf Engl 1993 2023. [DOI: 10.1016/j.radphyschem.2022.110698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
7
|
Rawashdeh M, Saade C. Establishment of diagnostic reference levels in low-dose renal computed tomography. Acta Radiol 2023; 64:829-836. [PMID: 35505591 DOI: 10.1177/02841851221095238] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Increased radiation doses from computed tomography (CT) examinations is well known with proven risks of inducing cancers for effective dose >100 mSv (according to some studies >50 mSvs). PURPOSE To establish the diagnostic reference level (DRL) for low-dose renal CT examinations in the evaluation of renal stones. MATERIAL AND METHODS Patient demographics, CT parameters, and dosimetric indices (CTDIvol and dose length product [DLP]) were collected from 12 tertiary hospitals that routinely perform renal CT in the detection and evaluation of renal stones over a period of 12 weeks. Data obtained from 1418 average-sized patients in each category were recorded. The median values of dosimetric indices for each site were calculated. The DRL values were defined as the 75th percentile of the distribution of the median values of CTDIvol and DLP. RESULTS There were no significant differences between patient demographics. Mean kVp and mAs for protocols were 121.67 ± 11.56 and 226.91 ± 78.44, respectively. The CTDIvol values were in the range of 2-36.2 mGy, while the DLP values were in the range of 43-1942 mGy.cm. The DRL for the CTDIvol was 16.15 mGy and for the DLP 851.77 mGy.cm. The local median values of CDTIvol and DLP are higher than DRL in two hospitals. CONCLUSION Comparison of local median values of CDTIvol and DLP with DRL suggests the needs of an optimization strategy in some hospitals.
Collapse
Affiliation(s)
- Mohammad Rawashdeh
- Department of Allied Medical Sciences, 108612Jordan University of Science and Technology, Irbid, Jordan
| | - Charbel Saade
- Medical Imaging Sciences, Faculty of Health Sciences, University College Cork, Cork, Ireland
| |
Collapse
|
8
|
Patient size as a parameter for determining Diagnostic Reference Levels for paediatric Computed Tomography (CT) procedures. Phys Med 2022; 102:55-65. [PMID: 36126468 DOI: 10.1016/j.ejmp.2022.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 08/28/2022] [Accepted: 09/12/2022] [Indexed: 11/22/2022] Open
Abstract
INTRODUCTION The paediatric radiation dose has never been studied in Sri Lanka, nor has a national diagnostic reference level (NDRL) established. Therefore, the primary aim of this study was to propose diagnostic reference levels (DRL) and achievable dose (AD) values for paediatric CT examinations based on size. METHODS A total of 658 paediatric (0-15 years) non-contrast-enhanced (NC) studies of head, chest and abdomen regions performed during six months in two dedicated paediatric hospitals (out of the three such institutions in the country) were included. For head examinations, the dose indexes were analysed based on age, while for body examinations, both age and effective diameter (Deff) were used. The median and the third quartile of the pooled dose distribution were given as AD and NDRL, respectively. RESULTS The AD ranges for the head, chest and abdomen regions based on CTDIvol were 45.8-57.2 mGy, 2.9-10.0 mGy and 3.8-10.3 mGy. The corresponding NDRL ranges were 45.8-95.8 mGy, 3.5-14.1 mGy and 4.5-11.9 mGy. The AD ranges based on SSDEdeff and deff were 3.5-9.6 mGy and 4.1-10.3 mGy in chest and abdomen regions. The corresponding NDRL were 4.5-14.1 mGy and 6.1-10.6 mGy. CONCLUSION Other institutions can use the present study DRLs as a reference dose for paediatric CT. The AD values can be used as a baseline for target dose optimisations, reducing doses up to 90%.
Collapse
|
9
|
Kadavigere R, Sukumar S. Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:983-991. [PMID: 35786667 DOI: 10.3233/xst-221172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND Pediatric population is more sensitive to the effects of radiation than adults. Establishing diagnostic reference level (DRL) is an efficient dose optimization technique implemented by many countries for reducing radiation dose during Computed Tomography (CT) examinations. OBJECTIVES To estimate radiation dose and establish a new local diagnostic reference level for CT head examination in the pediatric population. MATERIALS AND METHODS We prospectively recruited 143 pediatric patients referred for CT head examination with age ranging from 0-5 years old. All patients had undergone CT head examination using the standard pediatric head protocol. Volumetric CT dose index (CTDIvol) and dose length product (DLP) were recorded. The effective dose was first calculated. Then, 75th percentile of dose indices was calculated to establish DRLs. RESULTS DRLs in terms of CTDIvol and DLP are 23.84 mGy, 555.99 mGy.cm for patients <1 years old and 28.65 mGy, 794.99 mGy.cm for patients from 1-5 years old, respectively. Mean effective doses for <1 years old patients and 1-5 years old patients are 2.91 mSv and 2.78 mSv respectively. CONCLUSION The study concludes that DRL in terms of CTDIvol is lower but DRL in terms of DLP and the effective dose is higher compared to a few other studies which necessitate the need for dose optimization.
Collapse
Affiliation(s)
- Rajagopal Kadavigere
- Department of Radio diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India
| | - Suresh Sukumar
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India
| |
Collapse
|
10
|
Alzimami K, Sulieman A, Omer H, Jambi LK, Alfuraih A, Al Hossain N, Babikir E, Alkhorayef M, Khandaker MU, Bradley D. Evaluation of pediatric radiation doses in computed tomography procedures in the Kingdom of Saudi Arabia. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109679] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
11
|
Gricienė B, Šiukšterytė M. Local Diagnostic Reference Levels for Paediatric Head CT Procedures. Acta Med Litu 2021; 28:253-261. [PMID: 35474931 PMCID: PMC8958655 DOI: 10.15388/amed.2021.28.2.13] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/21/2021] [Accepted: 06/08/2021] [Indexed: 12/02/2022] Open
Abstract
Background. Patients, especially children, are exposed to substantially high doses of ionising radiation during computed tomography (CT) procedures. Children are several times more susceptible to ionising radiation than adults. Diagnostic reference levels (DRLs) are an important tool for monitoring and optimising patient radiation exposure from radiological procedures. The aim of this study is to estimate the ionising radiation exposure doses and set local DRLs for head CT examinations according to age and to compare local DRLs with national and European DRLs and with literature data in other countries. Materials and methods. Scan parameters of single-phase head CT examinations were collected. Patients were grouped by age in the following intervals: <1, 1−5, 5−10, 10−15 and 15−18 years. Local age-based DRLs set as the 3rd quartile of the median dose-length product (DLP) were calculated. Literature analysis was performed on PubMed search engine on inclusion criteria: publication date 2015–2020, used keywords paediatric computed tomography, paediatric CT, diagnostic reference levels (DRLs). The 23 articles discussing paediatric DRLs were further analysed. Results. Data was collected from 194 paediatric head CT examinations performed in 2019. The median DLP values for head CT were 144.3, 233.7, 246.4, 288.9, 315.5 for <1, 1−5, 5−10, 10−15 and 15−18 years old groups. Estimated local DRLs for head CT examinations are 170, 300, 310, 320, 360 mGy*cm for <1, 1−5, 5−10, 10−15 and 15−18 years age groups respectively and 130, 210, 275, 320 mGy*cm for 0−3 months, 3 months−1 year, 1−6 years and ≥ 6 years age groups respectively. Conclusions. Results of this study showed that settled new local DRLs of head CT examinations were 2–4 times lower than national DRLs and about 2 times lower than European DRLs. Moreover, the study indicated that paediatric head CT doses are significantly lower in comparison with those indicated in the majority of published data from other hospitals over the last 6 years. Patient dose assessment and local DRLs establishment plays important role in future exposure optimisation.
Collapse
|
12
|
Satharasinghe DM, Jeyasugiththan J, Wanninayake WMNMB, Pallewatte AS. Paediatric diagnostic reference levels in computed tomography: a systematic review. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2021; 41:R1-R27. [PMID: 33684071 DOI: 10.1088/1361-6498/abd840] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This study aims to review the existing literature on diagnostic reference levels (DRLs) in paediatric computed tomography (CT) procedures and the methodologies for establishing them. A comprehensive literature search was done in the popular databases such as PubMed and Google Scholar under the key words 'p(a)ediatric DRL', 'dose reference level', 'diagnostic reference level' and 'DRL'. Twenty-three articles originating from 15 countries were included. Differences were found in the methods used to establish paediatric CT DRLs across the world, including test subjects, reference phantom size, anatomical regions, modes of data collection and stratification techniques. The majority of the studies were based on retrospective patient surveys. The head, chest and abdomen were the common regions. The volume computed tomography dose index (CTDIvol) and dose-length product (DLP) were the dosimetric quantities chosen in the majority of publications. However, the size-specific dose estimate was a growing trend in the DRL concept of CT. A 16 cm diameter phantom was used by most of the publications when defining DRLs for head, chest and abdomen. The majority of the DRLs were given based on patient age, and the common age categories for head, chest and abdomen regions were 0-1, 1-5, 5-10 and 10-15 years. The DRL ranges for the head region were 18-68 mGy (CTDIvol) and 260-1608 mGy cm (DLP). For chest and abdomen regions the variations were 1.0-15.6 mGy, 10-496 mGy cm and 1.8-23 mGy, 65-807 mGy cm, respectively. All these DRLs were established for children aged 0-18 years. The wide range of DRL distributions in chest and abdomen regions can be attributed to the use of two different reference phantom sizes (16 and 32 cm), failure to follow a common methodology and inadequate dose optimisation actions. Therefore, an internationally accepted protocol should be followed when establishing DRLs. Moreover, these DRL variations suggest the importance of establish a national DRL for each country considering advanced techniques and dose reduction methodologies.
Collapse
Affiliation(s)
- D M Satharasinghe
- Department of Nuclear Science, University of Colombo, Colombo, Sri Lanka. Horizon Campus, Malabe, Sri Lanka
| | | | | | | |
Collapse
|
13
|
Muhammad NA, Abdul Karim MK, Abu Hassan H, Ahmad Kamarudin M, Ding Wong JH, Ng KH. Diagnostic Reference Level of Radiation Dose and Image Quality among Paediatric CT Examinations in A Tertiary Hospital in Malaysia. Diagnostics (Basel) 2020; 10:E591. [PMID: 32823818 PMCID: PMC7460376 DOI: 10.3390/diagnostics10080591] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 07/22/2020] [Accepted: 07/22/2020] [Indexed: 01/27/2023] Open
Abstract
Pediatrics are more vulnerable to radiation and are prone to dose compared to adults, requiring more attention to computed tomography (CT) optimization. Hence, diagnostic reference levels (DRLs) have been implemented as part of optimization process in order to monitor CT dose and diagnostic quality. The noise index has recently been endorsed to be included as a part of CT optimization in the DRLs report. In this study, we have therefore set local DRLs for pediatric CT examination with a noise index as an indicator of image quality. One thousand one hundred and ninety-two (1192) paediatric patients undergoing CT brain, CT thorax and CT chest-abdomen-pelvis (CAP) examinations were analyzed retrospectively and categorized into four age groups; group 1 (0-1 year), group 2 (1-5 years), group 3 (5-10 years) and group 4 (10-15 years). For each group, data such as the volume-weighted CT dose index (CTDIvol), dose-length product (DLP) and the effective dose (E) were calculated and DRLs for each age group set at 50th percentile were determined. Both CT dose and image noise values between age groups have differed significantly with p-value < 0.05. The highest CTDIvol and DLP values in all age groups with the lowest noise index value reported in the 10-15 age group were found in CT brain examination. In conclusion, there was a significant variation in doses and noise intensity among children of different ages, and the need to change specific parameters to fit the clinical requirement.
Collapse
Affiliation(s)
- Nor Azura Muhammad
- Department of Physics, Faculty of Science, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (N.A.M.); (M.A.K.)
| | - Muhammad Khalis Abdul Karim
- Department of Physics, Faculty of Science, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (N.A.M.); (M.A.K.)
- Centre of Diagnostic Nuclear Imaging, Faculty of Medicine, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Hasyma Abu Hassan
- Department of Imaging, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| | - Mazliana Ahmad Kamarudin
- Department of Physics, Faculty of Science, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (N.A.M.); (M.A.K.)
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical Imaging, University Malaya Medical Centre, Petaling Jaya 59100, Kuala Lumpur, Malaysia; (J.H.D.W.); (K.H.N.)
| | - Kwan Hoong Ng
- Department of Biomedical Imaging, University Malaya Medical Centre, Petaling Jaya 59100, Kuala Lumpur, Malaysia; (J.H.D.W.); (K.H.N.)
- Department of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| |
Collapse
|