Wang H, Li X, Xu L, Kuang Y. PET/SPECT/spectral-CT/CBCT imaging in a small-animal radiation therapy platform: A Monte Carlo study-Part I: Quad-modal imaging. Med Phys 2024; 51:2941-2954. [PMID: 38421665 DOI: 10.1002/mp.17007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 01/16/2024] [Accepted: 02/12/2024] [Indexed: 03/02/2024] Open
Abstract
BACKGROUND In spite of the tremendous potential of game-changing biological image- and/or biologically guided radiation therapy (RT) and adaptive radiation therapy for cancer treatment, existing limited strategies for integrating molecular imaging and/or biological information with RT have impeded the translation of preclinical research findings to clinical applications. Additionally, there is an urgent need for a highly integrated small-animal radiation therapy (SART) platform that can seamlessly combine therapeutic and diagnostic capabilities to comprehensively enhance RT for cancer treatment. PURPOSE We investigated a highly integrated quad-modal on-board imaging configuration combining positron emission tomography (PET), single-photon emission computed tomography (SPECT), photon-counting spectral CT, and cone-beam computed tomography (CBCT) in a SART platform using a Monte Carlo model as a proof-of-concept. METHODS The quad-modal on-board imaging configuration of the SART platform was designed and evaluated by using the GATE Monte Carlo code. A partial-ring on-board PET imaging subsystem, utilizing advanced semiconductor thallium bromide detector technology, was designed to achieve high sensitivity and spatial resolution. On-board SPECT, photon-counting spectral-CT, and CBCT imaging were performed using a single cadmium zinc telluride flat detector panel. The absolute peak sensitivity and scatter fraction of the PET subsystem were estimated by using simulated phantoms described in the NEMA NU-4 standard. The spatial resolution of the PET image of the platform was evaluated by imaging a simulated micro-Derenzo hot-rod phantom. To evaluate the quantitative imaging capability of the system's spectral CT, the Bayesian eigentissue decomposition (ETD) method was utilized to quantitatively decompose the virtual noncontrast (VNC) electron densities and iodine contrast agent fractions in the Kidney1 inserts mixed with the iodine contrast agent within the simulated phantoms. The performance of the proposed quad-model imaging in the platform was validated by imaging a simulated phantom with multiple imaging probes, including an iodine contrast agent and radioisotopes of 18F and 99mTc. RESULTS The PET subsystem demonstrated an absolute peak sensitivity of 18.5% at the scanner center, with an energy window of 175-560 KeV, and a scatter fraction of only 3.5% for the mouse phantom, with a default energy window of 480-540 KeV. The spatial resolution of PET on-board imaging exceeded 1.2 mm. All imaging probes were identified clearly within the phantom. The PET and SPECT images agreed well with the actual spatial distributions of the tracers within the phantom. Average relative errors on electron density and iodine contrast agent fraction in the Kidney1 inserts were less than 3%. High-quality PET images, SPECT images, spectral-CT images (including iodine contrast agent fraction images and VNC electron density images), and CBCT images of the simulated phantom demonstrated the comprehensive multimodal imaging capability of the system. CONCLUSIONS The results demonstrated the feasibility of the proposed quad-modal imaging configuration in a SART platform. The design incorporates anatomical, molecular, and functional information about tumors, thereby facilitating successful translation of preclinical studies into clinical practices.
Collapse
Affiliation(s)
- Hui Wang
- Medical Imaging and Translational Medicine Laboratory, Department of Radiotherapy, Affiliated Hangzhou Cancer Hospital, Westlake University School of Medicine, Hangzhou, Zhejiang, China
- Medical Physics Program, University of Nevada, Las Vegas, Nevada, USA
| | - Xiadong Li
- Medical Imaging and Translational Medicine Laboratory, Department of Radiotherapy, Affiliated Hangzhou Cancer Hospital, Westlake University School of Medicine, Hangzhou, Zhejiang, China
| | - Lixia Xu
- Medical Imaging and Translational Medicine Laboratory, Department of Radiotherapy, Affiliated Hangzhou Cancer Hospital, Westlake University School of Medicine, Hangzhou, Zhejiang, China
| | - Yu Kuang
- Medical Physics Program, University of Nevada, Las Vegas, Nevada, USA
| |
Collapse
|
2
|
He X, Trigila C, Ariño-Estrada G, Roncali E. Potential of Depth-of-Interaction-Based Detection Time Correction in Cherenkov Emitter Crystals for TOF-PET. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2023; 7:233-240. [PMID: 36994147 PMCID: PMC10042439 DOI: 10.1109/trpms.2022.3226950] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Cherenkov light can improve the timing resolution of Positron Emission Tomography (PET) radiation detectors, thanks to its prompt emission. Coincidence time resolutions (CTR) of ~30 ps were recently reported when using 3.2 mm-thick Cherenkov emitters. However, sufficient detection efficiency requires thicker crystals, causing the timing resolution to be degraded by the optical propagation inside the crystal. We report on depth-of-interaction (DOI) correction to mitigate the time-jitter due to the photon time spread in Cherenkov-based radiation detectors. We simulated the Cherenkov and scintillation light generation and propagation in 3 × 3 mm2 lead fluoride, lutetium oxyorthosilicate, bismuth germanate, thallium chloride, and thallium bromide. Crystal thicknesses varied from 9 to 18 mm with a 3-mm step. A DOI-based time correction showed a 2-to-2.5-fold reduction of the photon time spread across all materials and thicknesses. Results showed that highly refractive crystals, though producing more Cherenkov photons, were limited by an experimentally obtained high-cutoff wavelength and refractive index, restricting the propagation and extraction of Cherenkov photons mainly emitted at shorter wavelengths. Correcting the detection time using DOI information shows a high potential to mitigate the photon time spread. These simulations highlight the complexity of Cherenkov-based detectors and the competing factors in improving timing resolution.
Collapse
Affiliation(s)
- Xuzhi He
- Department of Biomedical Engineering at the University of California Davis, Davis, CA 95616 USA
| | - Carlotta Trigila
- Department of Biomedical Engineering at the University of California Davis, Davis, CA 95616 USA
| | - Gerard Ariño-Estrada
- Department of Biomedical Engineering at the University of California Davis, Davis, CA 95616 USA
| | - Emilie Roncali
- Department of Biomedical Engineering at the University of California Davis, Davis, CA 95616 USA
- Department of Radiology at University of California Davis, Sacramento, CA 95817 USA
| |
Collapse
|
3
|
Du J, Jones T. Technical opportunities and challenges in developing total-body PET scanners for mice and rats. EJNMMI Phys 2023; 10:2. [PMID: 36592266 PMCID: PMC9807733 DOI: 10.1186/s40658-022-00523-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 12/20/2022] [Indexed: 01/03/2023] Open
Abstract
Positron emission tomography (PET) is the most sensitive in vivo molecular imaging technique available. Small animal PET has been widely used in studying pharmaceutical biodistribution and disease progression over time by imaging a wide range of biological processes. However, it remains true that almost all small animal PET studies using mouse or rat as preclinical models are either limited by the spatial resolution or the sensitivity (especially for dynamic studies), or both, reducing the quantitative accuracy and quantitative precision of the results. Total-body small animal PET scanners, which have axial lengths longer than the nose-to-anus length of the mouse/rat and can provide high sensitivity across the entire body of mouse/rat, can realize new opportunities for small animal PET. This article aims to discuss the technical opportunities and challenges in developing total-body small animal PET scanners for mice and rats.
Collapse
Affiliation(s)
- Junwei Du
- grid.27860.3b0000 0004 1936 9684Department of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA
| | - Terry Jones
- grid.27860.3b0000 0004 1936 9684Department of Radiology, University of California at Davis, Davis, CA 95616 USA
| |
Collapse
|
4
|
Lee Y, Park C. Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study. NUCLEAR ENGINEERING AND TECHNOLOGY 2022. [DOI: 10.1016/j.net.2022.07.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
5
|
Trigila C, Ariño-Estrada G, Kwon SI, Roncali E. The Accuracy of Cerenkov Photons Simulation in Geant4/Gate Depends on the Parameterization of Primary Electron Propagation. FRONTIERS IN PHYSICS 2022; 10:891602. [PMID: 37220601 PMCID: PMC10201934 DOI: 10.3389/fphy.2022.891602] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Energetic electrons traveling in a dispersive medium can produce Cerenkov radiation. Cerenkov photons' prompt emission, combined with their predominantly forward emission direction with respect to the parent electron, makes them extremely promising to improve radiation detector timing resolution. Triggering gamma detections based on Cerenkov photons to achieve superior timing resolution is challenging due to the low number of photons produced per interaction. Monte Carlo simulations are fundamental to understanding their behavior and optimizing their pathway to detection. Therefore, accurately modeling the electron propagation and Cerenkov photons emission is crucial for reliable simulation results. In this work, we investigated the physics characteristics of the primary electrons (velocity, energy) and those of all emitted Cerenkov photons (spatial and timing distributions) generated by 511 keV photoelectric interactions in a bismuth germanate crystal using simulations with Geant4/GATE. Geant4 uses a stepwise particle tracking approach, and users can limit the electron velocity change per step. Without limiting it (default Geant4 settings), an electron mean step length of ~250 μm was obtained, providing only macroscopic modeling of electron transport, with all Cerenkov photons emitted in the forward direction with respect to the incident gamma direction. Limiting the electron velocity change per step reduced the electron mean step length (~0.200 μm), leading to a microscopic approach to its transport which more accurately modeled the electron physical properties in BGO at 511 keV. The electron and Cerenkov photons rapidly lost directionality, affecting Cerenkov photons' transport and, ultimately, their detection. Results suggested that a deep understanding of low energy physics is crucial to perform accurate optical Monte Carlo simulations and ultimately use them in TOF PET detectors.
Collapse
Affiliation(s)
- Carlotta Trigila
- Department of Biomedical Engineering, University of California Davis, Davis, CA, United States
| | - Gerard Ariño-Estrada
- Department of Biomedical Engineering, University of California Davis, Davis, CA, United States
| | - Sun Il Kwon
- Department of Biomedical Engineering, University of California Davis, Davis, CA, United States
| | - Emilie Roncali
- Department of Biomedical Engineering, University of California Davis, Davis, CA, United States
- Department of Radiology, University of California Davis, Davis, CA, United States
| |
Collapse
|
6
|
Li T, Luo S, Wang X, Zhang L. Alternative Lone-Pair ns 2 -Cation-Based Semiconductors beyond Lead Halide Perovskites for Optoelectronic Applications. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2008574. [PMID: 34060151 DOI: 10.1002/adma.202008574] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 03/22/2021] [Indexed: 06/12/2023]
Abstract
Lead halide perovskites have emerged in the last decade as advantageous high-performance optoelectronic semiconductors, and have undergone rapid development for diverse applications such as solar cells, light-emitting diodes , and photodetectors. While material instability and lead toxicity are still major concerns hindering their commercialization, they offer promising prospects and design principles for developing promising optoelectronic materials. The distinguished optoelectronic properties of lead halide perovskites stem from the Pb2+ cation with a lone-pair 6s2 electronic configuration embedded in a mixed covalent-ionic bonding lattice. Herein, we summarize alternative Pb-free semiconductors containing lone-pair ns2 cations, intending to offer insights for developing potential optoelectronic materials other than lead halide perovskites. We start with the physical underpinning of how the ns2 cations within the material lattice allow for superior optoelectronic properties. We then review the emerging Pb-free semiconductors containing ns2 cations in terms of structural dimensionality, which is crucial for optoelectronic performance. For each category of materials, the research progresses on crystal structures, electronic/optical properties, device applications, and recent efforts for performance enhancements are overviewed. Finally, the issues hindering the further developments of studied materials are surveyed along with possible strategies to overcome them, which also provides an outlook on the future research in this field.
Collapse
Affiliation(s)
- Tianshu Li
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Automobile Materials of MOE, and School of Materials Science and Engineering, Jilin University, Changchun, 130012, China
| | - Shulin Luo
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Automobile Materials of MOE, and School of Materials Science and Engineering, Jilin University, Changchun, 130012, China
| | - Xinjiang Wang
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Automobile Materials of MOE, and School of Materials Science and Engineering, Jilin University, Changchun, 130012, China
| | - Lijun Zhang
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Automobile Materials of MOE, and School of Materials Science and Engineering, Jilin University, Changchun, 130012, China
| |
Collapse
|
7
|
Ariño-Estrada G, Kim H, Du J, Cirignano LJ, Shah KS, Cherry SR. Energy and electron drift time measurements in a pixel CCI TlBr detector with 1.3 MeV prompt-gammas. Phys Med Biol 2021; 66:044001. [PMID: 33326951 DOI: 10.1088/1361-6560/abd419] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Assessing the position of the Bragg peak (BP) in hadron radiotherapy utilizing prompt-gamma imaging (PGI) presents many challenges in terms of detector physics. Gamma detectors with the capability of extracting the best energy, timing, and spatial information from each gamma interaction, as well as with high detection efficiency and count rate performance, are needed for this application. In this work we present the characterization of a pixel Čerenkov charge induction (CCI) thallium bromide (TlBr) detector in terms of energy and and electron drift time for its potential use in PGI. The CCI TlBr detector had dimensions of 4 × 4 × 5 mm3 and one of its electrodes was segmented in pixels with 1.7 mm pitch. A silicon photomultiplier (SiPM) was optically coupled to one of the faces of the TlBr slab to read out the Čerenkov light promptly emitted after the interaction of a gamma ray. The detector was operated stand-alone and the 1.275 prompt gammas from a 22Na radioactive source were used for the study. The electron drift time was obtained by combining the Čerenkov and charge induction signals and then used as a measure of the depth of interaction. The electron mobility in TlBr was estimated as ∼27 cm2 V-1 s-1. Energy resolutions between 3.4% and 4.0% at 1.275 MeV were obtained after depth-correction. These values improved to 3.0%-3.3% when events with drift times of 3-6 μs were selected. These results show the potential of pixel CCI TlBr detectors to resolve gamma interactions in the detector with mm-like accuracy in 3D and with excellent energy resolution. Previous studies with CCI TlBr devices have shown a timing resolution of <400 ps full width at half maximum when detecting 511 keV gamma rays, therefore, the timing accuracy is expected to improve with the increased energy of the gamma rays in PGI. While other important detector characteristics such as count rate capability remain to be studied, results from this work combined with other preliminary data show pixel CCI detectors can simultaneously provide excellent energy, timing, and spatial resolution performance and are a very promising option for PGI in hadron therapy.
Collapse
Affiliation(s)
- Gerard Ariño-Estrada
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616, United States of America
| | | | | | | | | | | |
Collapse
|
8
|
Ariño-Estrada G, Mitchell GS, Kim H, Du J, Kwon SI, Cirignano LJ, Shah KS, Cherry SR. First Cerenkov charge-induction (CCI) TlBr detector for TOF-PET and proton range verification. Phys Med Biol 2019; 64:175001. [PMID: 31344688 DOI: 10.1088/1361-6560/ab35c4] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Thallium bromide (TlBr) is a semiconductor material and, simultaneously, a good Cerenkov radiator. The performance of a TlBr detector that integrates two different readouts, the charge induction readout and the detection of Cerenkov light, was evaluated. A TlBr detector with dimensions of 4 × 4 × 5 mm3, with a monolithic cathode and an anode segmented into strips, was manufactured. One of the bare and polished 4 × 4 mm2 faces of the detector was coupled to a silicon photomultiplier (SiPM) to read out the Cerenkov light. Simultaneous timing and energy resolutions of <400 ps full width at half maximum (FWHM) and ~8.5% at 511 keV were measured using the Cerenkov detection and charge induction readouts, respectively. A coincidence time resolution of 330 ps was obtained when selecting Cerenkov events with amplitudes above 70 mV. The combination of both readouts showed the potential to resolve the depth-of-interaction (DOI) positioning, based on the improvement of energy resolution when selecting events with similar electron drift times. This manuscript sets the stage for a new family of semiconductor detectors that combine charge induction readout with the Cerenkov light detection. Such detectors can provide, simultaneously, outstanding timing, energy, and spatial resolution, and will be an excellent fit for applications that require the detection of high-energy gamma photons with high timing accuracy, such as time-of-flight positron emission tomography (TOF-PET) and prompt gamma imaging (PGI) to assess the particle range in hadron therapy.
Collapse
Affiliation(s)
- Gerard Ariño-Estrada
- Department of Biomedical Engineering, University of California Davis, Davis, CA, United States of America. Author to whom correspondence should be addressed
| | | | | | | | | | | | | | | |
Collapse
|