1
|
Midroni J, Salunkhe R, Liu Z, Chow R, Boldt G, Palma D, Hoover D, Vinogradskiy Y, Raman S. Incorporation of Functional Lung Imaging Into Radiation Therapy Planning in Patients With Lung Cancer: A Systematic Review and Meta-Analysis. Int J Radiat Oncol Biol Phys 2024:S0360-3016(24)00481-4. [PMID: 38631538 DOI: 10.1016/j.ijrobp.2024.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 03/27/2024] [Accepted: 04/02/2024] [Indexed: 04/19/2024]
Abstract
Our purpose was to provide an understanding of current functional lung imaging (FLI) techniques and their potential to improve dosimetry and outcomes for patients with lung cancer receiving radiation therapy (RT). Excerpta Medica dataBASE (EMBASE), PubMed, and Cochrane Library were searched from 1990 until April 2023. Articles were included if they reported on FLI in one of: techniques, incorporation into RT planning for lung cancer, or quantification of RT-related outcomes for patients with lung cancer. Studies involving all RT modalities, including stereotactic body RT and particle therapy, were included. Meta-analyses were conducted to investigate differences in dose-function parameters between anatomic and functional RT planning techniques, as well as to investigate correlations of dose-function parameters with grade 2+ radiation pneumonitis (RP). One hundred seventy-eight studies were included in the narrative synthesis. We report on FLI modalities, dose-response quantification, functional lung (FL) definitions, FL avoidance techniques, and correlations between FL irradiation and toxicity. Meta-analysis results show that FL avoidance planning gives statistically significant absolute reductions of 3.22% to the fraction of well-ventilated lung receiving 20 Gy or more, 3.52% to the fraction of well-perfused lung receiving 20 Gy or more, 1.3 Gy to the mean dose to the well-ventilated lung, and 2.41 Gy to the mean dose to the well-perfused lung. Increases in the threshold value for defining FL are associated with decreases in functional parameters. For intensity modulated RT and volumetric modulated arc therapy, avoidance planning results in a 13% rate of grade 2+ RP, which is reduced compared with results from conventional planning cohorts. A trend of increased predictive ability for grade 2+ RP was seen in models using FL information but was not statistically significant. FLI shows promise as a method to spare FL during thoracic RT, but interventional trials related to FL avoidance planning are sparse. Such trials are critical to understanding the effect of FL avoidance planning on toxicity reduction and patient outcomes.
Collapse
Affiliation(s)
- Julie Midroni
- Temerty Faculty of Medicine, University of Toronto, Toronto, Canada; Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada
| | - Rohan Salunkhe
- Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Zhihui Liu
- Biostatistics, Princess Margaret Cancer Center, Toronto, Canada
| | - Ronald Chow
- Temerty Faculty of Medicine, University of Toronto, Toronto, Canada; Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada; London Regional Cancer Program, London Health Sciences Centre, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada
| | - Gabriel Boldt
- London Regional Cancer Program, London Health Sciences Centre, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada
| | - David Palma
- London Regional Cancer Program, London Health Sciences Centre, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada; Ontario Institute for Cancer Research, Toronto, Canada
| | - Douglas Hoover
- London Regional Cancer Program, London Health Sciences Centre, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada
| | - Yevgeniy Vinogradskiy
- Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, United States of America; Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, United States of America
| | - Srinivas Raman
- Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Canada.
| |
Collapse
|
2
|
Jabbarpour A, Ghassel S, Lang J, Leung E, Le Gal G, Klein R, Moulton E. The Past, Present, and Future Role of Artificial Intelligence in Ventilation/Perfusion Scintigraphy: A Systematic Review. Semin Nucl Med 2023; 53:752-765. [PMID: 37080822 DOI: 10.1053/j.semnuclmed.2023.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 04/22/2023]
Abstract
Ventilation-perfusion (V/Q) lung scans constitute one of the oldest nuclear medicine procedures, remain one of the few studies performed in the acute setting, and are amongst the few performed in the emergency setting. V/Q studies have witnessed a long fluctuation in adoption rates in parallel to continuous advances in image processing and computer vision techniques. This review provides an overview on the status of artificial intelligence (AI) in V/Q scintigraphy. To clearly assess the past, current, and future role of AI in V/Q scans, we conducted a systematic Ovid MEDLINE(R) literature search from 1946 to August 5, 2022 in addition to a manual search. The literature was reviewed and summarized in terms of methodologies and results for the various applications of AI to V/Q scans. The PRISMA guidelines were followed. Thirty-one publications fulfilled our search criteria and were grouped into two distinct categories: (1) disease diagnosis/detection (N = 22, 71.0%) and (2) cross-modality image translation into V/Q images (N = 9, 29.0%). Studies on disease diagnosis and detection relied heavily on shallow artificial neural networks for acute pulmonary embolism (PE) diagnosis and were primarily published between the mid-1990s and early 2000s. Recent applications almost exclusively regard image translation tasks from CT to ventilation or perfusion images with modern algorithms, such as convolutional neural networks, and were published between 2019 and 2022. AI research in V/Q scintigraphy for acute PE diagnosis in the mid-90s to early 2000s yielded promising results but has since been largely neglected and thus have yet to benefit from today's state-of-the art machine-learning techniques, such as deep neural networks. Recently, the main application of AI for V/Q has shifted towards generating synthetic ventilation and perfusion images from CT. There is therefore considerable potential to expand and modernize the use of real V/Q studies with state-of-the-art deep learning approaches, especially for workflow optimization and PE detection at both acute and chronic stages. We discuss future challenges and potential directions to compensate for the lag in this domain and enhance the value of this traditional nuclear medicine scan.
Collapse
Affiliation(s)
- Amir Jabbarpour
- Department of Physics, Carleton University, Ottawa, Ontario, Canada
| | - Siraj Ghassel
- Electrical Engineering and Computer Science, University of Ottawa, Ottawa, Ontario, Canada
| | - Jochen Lang
- Electrical Engineering and Computer Science, University of Ottawa, Ottawa, Ontario, Canada
| | - Eugene Leung
- Division of Nuclear Medicine and Molecular Imaging, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Grégoire Le Gal
- Division of Hematology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Ran Klein
- Department of Physics, Carleton University, Ottawa, Ontario, Canada; Electrical Engineering and Computer Science, University of Ottawa, Ottawa, Ontario, Canada; Division of Nuclear Medicine and Molecular Imaging, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada; Department of Nuclear Medicine and Molecular Imaging, The Ottawa Hospital, Ottawa, Ontario, Canada.
| | - Eric Moulton
- Electrical Engineering and Computer Science, University of Ottawa, Ottawa, Ontario, Canada; Jubilant DraxImage Inc., Kirkland, Quebec, Canada
| |
Collapse
|
3
|
Wallat EM, Wuschner AE, Flakus MJ, Gerard SE, Christensen GE, Reinhardt JM, Bayouth JE. Predicting pulmonary ventilation damage after radiation therapy for nonsmall cell lung cancer using a ResNet generative adversarial network. Med Phys 2023; 50:3199-3209. [PMID: 36779695 DOI: 10.1002/mp.16311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Revised: 02/01/2023] [Accepted: 02/06/2023] [Indexed: 02/14/2023] Open
Abstract
BACKGROUND Functional lung avoidance radiation therapy (RT) is a technique being investigated to preferentially avoid specific regions of the lung that are predicted to be more susceptible to radiation-induced damage. Reducing the dose delivered to high functioning regions may reduce the occurrence radiation-induced lung injuries (RILIs) and toxicities. However, in order to develop effective lung function-sparing plans, accurate predictions of post-RT ventilation change are needed to determine which regions of the lung should be spared. PURPOSE To predict pulmonary ventilation change following RT for nonsmall cell lung cancer using machine learning. METHODS A conditional generative adversarial network (cGAN) was developed with data from 82 human subjects enrolled in a randomized clinical trial approved by the institution's IRB to predict post-RT pulmonary ventilation change. The inputs to the network were the pre-RT pulmonary ventilation map and radiation dose distribution. The loss function was a combination of the binary cross-entropy loss and an asymmetrical structural similarity index measure (aSSIM) function designed to increase penalization of under-prediction of ventilation damage. Network performance was evaluated against a previously developed polynomial regression model using a paired sample t-test for comparison. Evaluation was performed using eight-fold cross-validation. RESULTS From the eight-fold cross-validation, we found that relative to the polynomial model, the cGAN model significantly improved predicting regions of ventilation damage following radiotherapy based on true positive rate (TPR), 0.14±0.15 to 0.72±0.21, and Dice similarity coefficient (DSC), 0.19±0.16 to 0.46±0.14, but significantly declined in true negative rate, 0.97±0.05 to 0.62±0.21, and accuracy, 0.79±0.08 to 0.65±0.14. Additionally, the average true positive volume increased from 104±119 cc in the POLY model to 565±332 cc in the cGAN model, and the average false negative volume decreased from 654±361 cc in the POLY model to 193±163 cc in the cGAN model. CONCLUSIONS The proposed cGAN model demonstrated significant improvement in TPR and DSC. The higher sensitivity of the cGAN model can improve the clinical utility of functional lung avoidance RT by identifying larger volumes of functional lung that can be spared and thus decrease the probability of the patient developing RILIs.
Collapse
Affiliation(s)
- Eric M Wallat
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Antonia E Wuschner
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Mattison J Flakus
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Sarah E Gerard
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa, USA
| | - Gary E Christensen
- Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa, USA.,Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA
| | - Joseph M Reinhardt
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa, USA.,Department of Radiology, University of Iowa, Iowa City, Iowa, USA
| | - John E Bayouth
- Department of Radiation Medicine, Oregon Health & Science University, Portland, Oregon, USA
| |
Collapse
|
4
|
Liu Z, Tian Y, Miao J, Men K, Wang W, Wang X, Zhang T, Bi N, Dai J. Deriving Pulmonary Ventilation Images From Clinical 4D-CBCT Using a Deep Learning-Based Model. Front Oncol 2022; 12:889266. [PMID: 35586492 PMCID: PMC9109610 DOI: 10.3389/fonc.2022.889266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 04/05/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose The current algorithms for measuring ventilation images from 4D cone-beam computed tomography (CBCT) are affected by the accuracy of deformable image registration (DIR). This study proposes a new deep learning (DL) method that does not rely on DIR to derive ventilation images from 4D-CBCT (CBCT-VI), which was validated with the gold-standard single-photon emission-computed tomography ventilation image (SPECT-VI). Materials and Methods This study consists of 4D-CBCT and 99mTc-Technegas SPECT/CT scans of 28 esophagus or lung cancer patients. The scans were rigidly registered for each patient. Using these data, CBCT-VI was derived using a deep learning-based model. Two types of model input data are studied, namely, (a) 10 phases of 4D-CBCT and (b) two phases of peak-exhalation and peak-inhalation of 4D-CBCT. A sevenfold cross-validation was applied to train and evaluate the model. The DIR-dependent methods (density-change-based and Jacobian-based methods) were used to measure the CBCT-VIs for comparison. The correlation was calculated between each CBCT-VI and SPECT-VI using voxel-wise Spearman's correlation. The ventilation images were divided into high, medium, and low functional lung regions. The similarity of different functional lung regions between SPECT-VI and each CBCT-VI was evaluated using the dice similarity coefficient (DSC). One-factor ANONA model was used for statistical analysis of the averaged DSC for the different methods of generating ventilation images. Results The correlation values were 0.02 ± 0.10, 0.02 ± 0.09, and 0.65 ± 0.13/0.65 ± 0.15, and the averaged DSC values were 0.34 ± 0.04, 0.34 ± 0.03, and 0.59 ± 0.08/0.58 ± 0.09 for the density change, Jacobian, and deep learning methods, respectively. The strongest correlation and the highest similarity with SPECT-VI were observed for the deep learning method compared to the density change and Jacobian methods. Conclusion The results showed that the deep learning method improved the accuracy of correlation and similarity significantly, and the derived CBCT-VIs have the potential to monitor the lung function dynamic changes during radiotherapy.
Collapse
Affiliation(s)
- Zhiqiang Liu
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| | - Yuan Tian
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| | - Junjie Miao
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| | - Kuo Men
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| | - Wenqing Wang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| | - Xin Wang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| | - Tao Zhang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| | - Nan Bi
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| | - Jianrong Dai
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Beijing, China
| |
Collapse
|