1
|
Machine learning enabled detection of COVID-19 pneumonia using exhaled breath analysis: a proof-of-concept study. J Breath Res 2024; 18:026009. [PMID: 38382095 DOI: 10.1088/1752-7163/ad2b6e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 02/21/2024] [Indexed: 02/23/2024]
Abstract
Detection of the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) relies on real-time-reverse-transcriptase polymerase chain reaction (RT-PCR) on nasopharyngeal swabs. The false-negative rate of RT-PCR can be high when viral burden and infection is localized distally in the lower airways and lung parenchyma. An alternate safe, simple and accessible method for sampling the lower airways is needed to aid in the early and rapid diagnosis of COVID-19 pneumonia. In a prospective unblinded observational study, patients admitted with a positive RT-PCR and symptoms of SARS-CoV-2 infection were enrolled from three hospitals in Ontario, Canada. Healthy individuals or hospitalized patients with negative RT-PCR and without respiratory symptoms were enrolled into the control group. Breath samples were collected and analyzed by laser absorption spectroscopy (LAS) for volatile organic compounds (VOCs) and classified by machine learning (ML) approaches to identify unique LAS-spectra patterns (breathprints) for SARS-CoV-2. Of the 135 patients enrolled, 115 patients provided analyzable breath samples. Using LAS-breathprints to train ML classifier models resulted in an accuracy of 72.2%-81.7% in differentiating between SARS-CoV2 positive and negative groups. The performance was consistent across subgroups of different age, sex, body mass index, SARS-CoV-2 variants, time of disease onset and oxygen requirement. The overall performance was higher than compared to VOC-trained classifier model, which had an accuracy of 63%-74.7%. This study demonstrates that a ML-based breathprint model using LAS analysis of exhaled breath may be a valuable non-invasive method for studying the lower airways and detecting SARS-CoV-2 and other respiratory pathogens. The technology and the ML approach can be easily deployed in any setting with minimal training. This will greatly improve access and scalability to meet surge capacity; allow early and rapid detection to inform therapy; and offers great versatility in developing new classifier models quickly for future outbreaks.
Collapse
|
2
|
The optimization and comparison of two high-throughput faecal headspace sampling platforms: the microchamber/thermal extractor and hi-capacity sorptive extraction probes (HiSorb). J Breath Res 2024; 18:026007. [PMID: 38237170 DOI: 10.1088/1752-7163/ad2002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 01/18/2024] [Indexed: 02/06/2024]
Abstract
Disease detection and monitoring using volatile organic compounds (VOCs) is becoming increasingly popular. For a variety of (gastrointestinal) diseases the microbiome should be considered. As its output is to large extent volatile, faecal volatilomics carries great potential. One technical limitation is that current faecal headspace analysis requires specialized instrumentation which is costly and typically does not work in harmony with thermal desorption units often utilized in e.g. exhaled breath studies. This lack of harmonization hinders uptake of such analyses by the Volatilomics community. Therefore, this study optimized and compared two recently harmonized faecal headspace sampling platforms:High-capacity Sorptive extraction (HiSorb) probesand theMicrochamber thermal extractor (Microchamber). Statistical design of experiment was applied to find optimal sampling conditions by maximizing reproducibility, the number of VOCs detected, and between subject variation. To foster general applicability those factors were defined using semi-targeted as well as untargeted metabolic profiles. HiSorb probes were found to result in a faster sampling procedure, higher number of detected VOCs, and higher stability. The headspace collection using the Microchamber resulted in a lower number of detected VOCs, longer sampling times and decreased stability despite a smaller number of interfering VOCs and no background signals. Based on the observed profiles, recommendations are provided on pre-processing and study design when using either one of both platforms. Both can be used to perform faecal headspace collection, but altogether HiSorb is recommended.
Collapse
|
3
|
Combining Thermal Desorption with Selected Ion Flow Tube Mass Spectrometry for Analyses of Breath Volatile Organic Compounds. Anal Chem 2024; 96:1397-1401. [PMID: 38243802 PMCID: PMC10831795 DOI: 10.1021/acs.analchem.3c04286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 11/21/2023] [Accepted: 12/26/2023] [Indexed: 01/22/2024]
Abstract
An instrument integrating thermal desorption (TD) to selected ion flow tube mass spectrometry (SIFT-MS) is presented, and its application to analyze volatile organic compounds (VOCs) in human breath is demonstrated for the first time. The rationale behind this development is the need to analyze breath samples in large-scale multicenter clinical projects involving thousands of patients recruited in different hospitals. Following adapted guidelines for validating analytical techniques, we developed and validated a targeted analytical method for 21 compounds of diverse chemical class, chosen for their clinical and biological relevance. Validation has been carried out by two independent laboratories, using calibration standards and real breath samples from healthy volunteers. The merging of SIFT-MS and TD integrates the rapid analytical capabilities of SIFT-MS with the capacity to collect breath samples across multiple hospitals. Thanks to these features, the novel instrument has the potential to be easily employed in clinical practice.
Collapse
|
4
|
Breath biomarkers in Non-Carcinogenic diseases. Clin Chim Acta 2024; 552:117692. [PMID: 38065379 DOI: 10.1016/j.cca.2023.117692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 12/02/2023] [Accepted: 12/03/2023] [Indexed: 12/19/2023]
Abstract
The analysis of volatile organic compounds (VOCs) from human matrices like breath, perspiration, and urine has received increasing attention from academic and medical researchers worldwide. These biological-borne VOCs molecules have characteristics that can be directly related to physiologic and pathophysiologic metabolic processes. In this work, gathers a total of 292 analytes that have been identified as potential biomarkers for the diagnosis of various non-carcinogenic diseases. Herein we review the advances in VOCs with a focus on breath biomarkers and their potential role as minimally invasive tools to improve diagnosis prognosis and therapeutic monitoring.
Collapse
|
5
|
Impact of thermal desorption tubes on the variability of exhaled breath data. J Breath Res 2023; 18:016008. [PMID: 38096565 DOI: 10.1088/1752-7163/ad15a3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 12/14/2023] [Indexed: 12/23/2023]
Abstract
Due to the overall low abundance of volatile compounds in exhaled breath, it is necessary to preconcentrate the sample prior to traditional thermal desorption (TD) gas chromatography mass spectrometry analysis. While certain aspects of TD tubes, such as volatile storage, have been evaluated, many aspects remain uncharacterized. Two common TD tubes, Tenax TA and Biomonitoring 5TD tubes, were evaluated for background content and flow rate variability. The data illustrate that the Biomonitoring 5TD tubes have the highest number (23) and abundance of background contamination greater than 3x the mean noise when compared to Tenax TA (13) and empty tubes (9). Tentative identifications of the compounds in the background contamination experiment show that greater than 59% (16/27) of the compounds identified have been reported in the breath literature. The data illustrate the TD tube background abundance could account for more than 70% of the chromatographic signal from exhaled breath for these select compounds. Flow rate measurements of 200 Tenax TA and 200 Biomonitoring 5TD tubes show a large range in measured flow rates among the TD tubes (Tenax: 252.9-284.0 ml min-1, 5TD: 220.6-255.1 ml min-1). Finally, TD tubes of each type, Tenax TA and Biomonitoring 5TD, previously established to have high, medium, and low flow rates, show insignificant differences (p> 0.05) among the tubes of different flow rates, using both gas standards and an exhaled breath from a peppermint experiment. Collectively, these results establish overall background compounds attributed to each TD tube type tested. Additionally, while measured flow rate variability is present and plausibly impacts exhaled breath results, the data demonstrate no statistically significant difference was observed between tubes showing high, medium, and low flow rates from two separate sample types.
Collapse
|
6
|
Preservation of exhaled breath samples for analysis by off-line SESI-HRMS: proof-of-concept study. J Breath Res 2023; 18:011002. [PMID: 38029449 DOI: 10.1088/1752-7163/ad10e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 11/29/2023] [Indexed: 12/01/2023]
Abstract
Secondary electrospray ionization-high resolution mass spectrometry (SESI-HRMS) is an established technique in the field of breath analysis characterized by its short analysis time, as well as high levels of sensitivity and selectivity. Traditionally, SESI-HRMS has been used for real-time breath analysis, which requires subjects to be at the location of the analytical platform. Therefore, it limits the possibilities for an introduction of this methodology in day-to-day clinical practice. However, recent methodological developments have shown feasibility on the remote sampling of exhaled breath in Nalophan® bags prior to measurement using SESI-HRMS. To further explore the range of applications of this method, we conducted a proof-of-concept study to assess the impact of the storage time of exhaled breath in Nalophan® bags at different temperatures (room temperature and dry ice) on the relative intensities of the compounds. In addition, we performed a detailed study of the storage effect of 27 aldehydes related to oxidative stress. After 2 h of storage, the mean of intensity of allm/zsignals relative to the samples analyzed without prior storage remained above 80% at both room temperature and dry ice. For the 27 aldehydes, the mean relative intensity losses were lower than 20% at 24 h of storage, remaining practically stable since the first hour of storage following sample collection. Furthermore, the mean relative intensity of most aldehydes in samples stored at room temperature was higher than those stored in dry ice, which could be related to water vapor condensation issues. These findings indicate that the exhaled breath samples could be preserved for hours with a low percentage of mean relative intensity loss, thereby allowing more flexibility in the logistics of off-line SESI-HRMS studies.
Collapse
|
7
|
Water interference in the chromatographic analysis of exhaled breath samples: Challenges and mitigation strategies. J Chromatogr A 2023; 1710:464372. [PMID: 37774466 DOI: 10.1016/j.chroma.2023.464372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 09/06/2023] [Accepted: 09/07/2023] [Indexed: 10/01/2023]
Abstract
This study demonstrates the adverse effects of water in exhaled breath samples on the accuracy of breath biomarker analysis when using gas chromatography. The presence of water in exhaled breath significantly modifies the retention times and peak areas of compounds, particularly for low-boiling, early eluting compounds. To tackle this issue, a two-step approach is introduced. The process begins with thorough desorption of the sorbent tube using a high split ratio and a short analysis duration, followed by a secondary analysis of the same tube. The efficacy of the new, straightforward approach was illustrated using humid breath samples and 57 compound standard mixture. This study highlights the importance of proper sample pretreatment and analysis to ensure reliable and accurate results in clinical research.
Collapse
|
8
|
A low-cost internal standard loader for solid-phase sorbing tools. J Breath Res 2023; 17:046008. [PMID: 37567168 DOI: 10.1088/1752-7163/acef4b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 08/11/2023] [Indexed: 08/13/2023]
Abstract
Solid-phase sorption is widely used for the analysis of gaseous specimens as it allows at the same time to preconcentrate target analytes and store samples for relatively long periods. The addition of internal standards (ISs) in the analytical workflow can greatly reduce the variability of the analyses and improve the reliability of the protocols. In this work, we describe the development and testing of a portable system for the reliable production of gaseous mixture of8D-Toluene in a 1L Silonite canister as well as its reproducible loading into solid-phase sorbing tools as ISs. The portable system was tested using needle trap microextraction, solid-phase extraction, and thin-film microextraction techniques commonly employed for the analysis of gaseous samples. Even though our specific interest is in breath analysis, the system can also be used for the collection of any kind of gaseous specimen. A microcontroller allows the fine control of the sampling flow by a digital mass flow controller. Flow rate and sample volume could be set either through a rotary encoder mounted onto the control board or through a dedicated android app. The variability of the airflow is in the range 5-200 ml min-1and it is lower than 1%, whereas the variability of the IS (8D-Toluene) concentration dispensed over time by the loader measured by selected-ion flow-tube mass spectrometry (MS) is <3%. This combination resulted in intra- and inter-day precision of the amount loaded in the sorbent tools lower than 15%. No carry-over was detected in the loader after the delivery of the8D-Toluene measured by gas chromatography-MS. The8D-Toluene concentration in the canister was stable for up to three weeks at room temperature.
Collapse
|
9
|
Breath Testing in the Surgical Setting: Applications, Challenges, and Future Perspectives. Eur Surg Res 2023; 64:315-322. [PMID: 37311421 PMCID: PMC10614239 DOI: 10.1159/000531504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 06/05/2023] [Indexed: 06/15/2023]
Abstract
BACKGROUND The potential for exhaled breath to be a valuable diagnostic tool is often overlooked as it can be difficult to imagine how a barely visible sample of breath could hold such a rich source of information about the state of our health. However, technological advances over the last 50 years have enabled us to detect volatile organic compounds (VOCs) present in exhaled breath, and this provides the key to understanding the wealth of information contained within these readily available samples. SUMMARY VOCs are produced as a by-product of metabolism; hence, changes in the underlying physiological processes will be reflected in the exact composition of VOCs in exhaled breath. It has been shown that characteristic changes occur in the breath VOC profile associated with certain diseases including cancer, which may enable the non-invasive detection of cancer at primary care level for patients with vague symptoms. The use of breath testing as a diagnostic tool has many advantages. It is non-invasive and quick, and the test is widely accepted by patients and clinicians. However, breath samples provide a snapshot of the VOCs present in a particular patient at a given point in time, so this can be heavily influenced by external factors such as diet, smoking, and the environment. These must all be accounted for when attempting to draw conclusions about disease status. This review focuses on the current applications for breath testing in the field of surgery, as well as discussing the challenges encountered with developing a breath test in a clinical environment. The future of breath testing in the surgical setting is also discussed, including the translation of breath research into clinical practice. KEY MESSAGES Analysis of VOCs in exhaled breath can identify the presence of underlying disease including cancer as well as other infectious or inflammatory conditions. Despite the patient factors, environmental factors, storage, and transport considerations that must be accounted for, breath testing demonstrates ideal characteristics for a triage test, being non-invasive, simple, and universally acceptable to patients and clinicians. Many novel biomarkers and diagnostic tests fail to translate into clinical practice because their potential clinical application does not align with the requirements and unmet needs of the healthcare sector. Non-invasive breath testing, however, has the great potential to revolutionise the early detection of diseases, such as cancer, in the surgical setting for patients with vague symptoms.
Collapse
|
10
|
Methods to Detect Volatile Organic Compounds for Breath Biopsy Using Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry. Molecules 2023; 28:molecules28114533. [PMID: 37299010 DOI: 10.3390/molecules28114533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 05/25/2023] [Accepted: 05/29/2023] [Indexed: 06/12/2023] Open
Abstract
Volatile organic compounds (VOCs) are byproducts from metabolic pathways that can be detected in exhaled breath and have been reported as biomarkers for different diseases. The gold standard for analysis is gas chromatography-mass spectrometry (GC-MS), which can be coupled with various sampling methods. The current study aims to develop and compare different methods for sampling and preconcentrating VOCs using solid-phase microextraction (SPME). An in-house sampling method, direct-breath SPME (DB-SPME), was developed to directly extract VOCs from breath using a SPME fiber. The method was optimized by exploring different SPME types, the overall exhalation volume, and breath fractionation. DB-SPME was quantitatively compared to two alternative methods involving the collection of breath in a Tedlar bag. In one method, VOCs were directly extracted from the Tedlar bag (Tedlar-SPME) and in the other, the VOCs were cryothermally transferred from the Tedlar bag to a headspace vial (cryotransfer). The methods were verified and quantitatively compared using breath samples (n = 15 for each method respectively) analyzed by GC-MS quadrupole time-of-flight (QTOF) for compounds including but not limited to acetone, isoprene, toluene, limonene, and pinene. The cryotransfer method was the most sensitive, demonstrating the strongest signal for the majority of the VOCs detected in the exhaled breath samples. However, VOCs with low molecular weights, including acetone and isoprene, were detected with the highest sensitivity using the Tedlar-SPME. On the other hand, the DB-SPME was less sensitive, although it was rapid and had the lowest background GC-MS signal. Overall, the three breath-sampling methods can detect a wide variety of VOCs in breath. The cryotransfer method may be optimal when collecting a large number of samples using Tedlar bags, as it allows the long-term storage of VOCs at low temperatures (-80 °C), while Tedlar-SPME may be more effective when targeting relatively small VOCs. The DB-SPME method may be the most efficient when more immediate analyses and results are required.
Collapse
|
11
|
Investigation of an individual with background levels of exhaled isoprene: a case study. J Breath Res 2023; 17. [PMID: 36596256 DOI: 10.1088/1752-7163/acaf98] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Accepted: 01/03/2023] [Indexed: 01/04/2023]
Abstract
Isoprene is one of the most abundant and most frequently evaluated volatile organic compounds in exhaled breath. Recently, several individuals with background levels of exhaled isoprene have been identified. Here, case study data are provided for an individual, identified from a previous study, with this low prevalence phenotype. It is hypothesized that the individual will illustrate low levels of exhaled isoprene at rest and during exercise. At rest, the subject (7.1 ppb) shows background (μ= 14.2 ± 7.0 ppb) levels of exhaled isoprene while the control group illustrates significantly higher quantities (μ= 266.2 ± 72.3 ppb) via proton transfer reaction mass spectrometry (PTR-MS). The result, background levels of isoprene at rest, is verified by thermal desorption gas chromatography mass spectrometry (TD-GC-MS) collections with the individual showing -3.6 ppb exhaled isoprene while the room background containedμ= -4.1 ± 0.1 ppb isoprene. As isoprene has been shown previously to increase at the initiation of exercise, exercise bike experiments were performed with the individual identified with low isoprene, yielding low and invariant levels of exhaled isoprene (μ= 6.6 ± 0.1 ppb) during the exercise while control subjects illustrated an approximate 2.5-fold increase (preμ= 286.3 ± 43.8 ppb, exerciseμ= 573.0 ± 147.8 ppb) in exhaled isoprene upon exercise start. Additionally, exhaled breath bag data showed a significant decrease in isoprene (delta post/pre, p = 0.0078) of the control group following the exercise regimen. Finally, TD-GC-MS results for exhaled isoprene from the individual's family (mother, father, sister and maternal grandmother) illustrated that the mother and father exhibited isoprene values (28.5 ppb, 77.2 ppb) below control samples 95% confidence interval (μ= 166.8 ± 43.3 ppb) while the individual's sister (182.0 ppb) was within the control range. These data provide evidence for a large dynamic range in exhaled isoprene in this family. Collectively, these results provide additional data surrounding the existence of a small population of individuals with background levels of exhaled isoprene.
Collapse
|
12
|
Common Strategies and Factors Affecting Off-Line Breath Sampling and Volatile Organic Compounds Analysis Using Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS). Metabolites 2022; 13:metabo13010008. [PMID: 36676933 PMCID: PMC9866406 DOI: 10.3390/metabo13010008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 12/14/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022] Open
Abstract
An analysis of exhaled breath enables specialists to noninvasively monitor biochemical processes and to determine any pathological state in the human body. Breath analysis holds the greatest potential to remold and personalize diagnostics; however, it requires a multidisciplinary approach and collaboration of many specialists. Despite the fact that breath is considered to be a less complex matrix than blood, it is not commonly used as a diagnostic and prognostic tool for early detection of disordered conditions due to its problematic sampling, analysis, and storage. This review is intended to determine, standardize, and marshal experimental strategies for successful, reliable, and especially, reproducible breath analysis.
Collapse
|
13
|
Expert considerations and consensus for using dogs to detect human SARS-CoV-2-infections. Front Med (Lausanne) 2022; 9:1015620. [PMID: 36569156 PMCID: PMC9773891 DOI: 10.3389/fmed.2022.1015620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 11/17/2022] [Indexed: 12/13/2022] Open
|
14
|
Millimeter-wave gas spectroscopy for breath analysis of COPD patients in comparison to GC-MS. J Breath Res 2022; 16. [PMID: 35688126 DOI: 10.1088/1752-7163/ac77aa] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 06/10/2022] [Indexed: 01/12/2023]
Abstract
The analysis of human breath is a very active area of research, driven by the vision of a fast, easy, and non-invasive tool for medical diagnoses at the point of care. Millimeter-wave gas spectroscopy (MMWGS) is a novel, well-suited technique for this application as it provides high sensitivity, specificity and selectivity. Most of all, it offers the perspective of compact low-cost systems to be used in doctors' offices or hospitals. In this work, we demonstrate the analysis of breath samples acquired in a medical environment using MMWGS and evaluate validity, reliability, as well as limitations and perspectives of the method. To this end, we investigated 28 duplicate samples from chronic obstructive lung disease patients and compared the results to gas chromatography-mass spectrometry (GC-MS). The quantification of the data was conducted using a calibration-free fit model, which describes the data precisely and delivers absolute quantities. For ethanol, acetone, and acetonitrile, the results agree well with the GC-MS measurements and are as reliable as GC-MS. The duplicate samples deviate from the mean values by only 6% to 18%. Detection limits of MMWGS depend strongly on the molecular species. For example, acetonitrile can be traced down to 1.8 × 10-12mol by the MMWGS system, which is comparable to the GC-MS system. We observed correlations of abundances between formaldehyde and acetaldehyde as well as between acetonitrile and acetaldehyde, which demonstrates the potential of MMWGS for breath research.
Collapse
|
15
|
pyAIR-A New Software Tool for Breathomics Applications-Searching for Markers in TD-GC-HRMS Analysis. Molecules 2022; 27:molecules27072063. [PMID: 35408461 PMCID: PMC9000534 DOI: 10.3390/molecules27072063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/16/2022] [Accepted: 03/17/2022] [Indexed: 11/16/2022] Open
Abstract
Volatile metabolites in exhaled air have promising potential as diagnostic biomarkers. However, the combination of low mass, similar chemical composition, and low concentrations introduces the challenge of sorting the data to identify markers of value. In this paper, we report the development of pyAIR, a software tool for searching for volatile organic compounds (VOCs) markers in multi-group datasets, tailored for Thermal-Desorption Gas-Chromatography High Resolution Mass-Spectrometry (TD-GC-HRMS) output. pyAIR aligns the compounds between samples by spectral similarity coupled with retention times (RT), and statistically compares the groups for compounds that differ by intensity. This workflow was successfully tested and evaluated on gaseous samples spiked with 27 model VOCs at six concentrations, divided into three groups, down to 0.3 nL/L. All analytes were correctly detected and aligned. More than 80% were found to be significant markers with a p-value < 0.05; several were classified as possibly significant markers (p-value < 0.1), while a few were removed due to background level. In all group comparisons, low rates of false markers were found. These results showed the potential of pyAIR in the field of trace-level breathomics, with the capability to differentially examine several groups, such as stages of illness.
Collapse
|
16
|
Odor characterization of a cavity preservation using emission test chambers by different sensory evaluation methods and sampling concepts for instrumental analysis. TALANTA OPEN 2022. [DOI: 10.1016/j.talo.2022.100098] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
|
17
|
Breath collection protocol for SARs-CoV-2 testing in an ambulatory setting. J Breath Res 2022; 16. [DOI: 10.1088/1752-7163/ac4e2c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 01/24/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Breath research during the SARS-CoV-2 pandemic offers an opportunity for discovery of a rapid point-of-care screening test, but also introduces a hazard to researchers collecting, transporting and analyzing breath samples not only for COVID -19 research, but all human breath-related research during the ongoing pandemic. Safe workflows to protect study participants and staff collecting and analysing the samples must be determined. We developed a SARS-CoV-2 breath test protocol for collection and processing of breath samples in ambulatory care COVID-19 testing sites and prospectively evaluated the protocol. 528 breath samples from 393 participants at COVID-19 testing sites were safely collected, transported, stored, and analysed with zero transmission to staff. Our method development for the safe collection of samples included the examination of 2 different filters for added safety. We discovered the use of filters leads to increased sample contamination and/or reduction of endogenous features in breath samples. Personal protective equipment (PPE) is essential for all breath collection while SARS-CoV-2 remains wide-spread through the general population. We have demonstrated that use of completely disposable breath collection devices and PPE, are sufficient for safe collection. Filters in the workflow add complexity to an already complex breath matrix and may compromise bio-safety.
Collapse
|
18
|
Preservation of vapor samples on adsorbent alumina capillaries and implications for field sampling. J Chromatogr A 2021; 1660:462670. [PMID: 34814090 PMCID: PMC9832929 DOI: 10.1016/j.chroma.2021.462670] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 11/01/2021] [Accepted: 11/02/2021] [Indexed: 01/13/2023]
Abstract
Dynamic vapor microextraction (DVME) is a vapor preconcentration method that employs a capillary trap coated with an adsorbent, followed by solvent elution to recover the sample. DVME has been developed for applications in the laboratory, including highly precise vapor pressure measurements, and in the field. When vapor collection is conducted outside the laboratory, samples must almost always undergo some interval of storage representing the time between collection and analysis. This interval may be hours, days, or longer, depending on the situation. Regardless, in all situations there must be confidence that the integrity of the samples is maintained until processing and analysis. In this paper, we present results of two studies that tested the stability of a 50% weathered gasoline headspace sample on alumina PLOT (porous layer open tubular) capillaries stored at room temperature for periods from 24 h up to 20 wk. We used principal component analysis (PCA) to reduce the dimensionality of the chromatographic and mass spectral data and elucidate trends in stability with respect to the complex sample's range of hydrocarbon classes and molecular weights. Both analyses identified changes over storage periods of six weeks or more. The hydrocarbon class analysis, which used selected ion monitoring (SIM) data as input, proved more sensitive to changes over shorter storage periods. Sample integrity was preserved for at least 24 h, but losses, especially of high-volatility compounds, occurred by 168 h (7 d). Near total loss of sample occurred by 20 wk. These findings, which are specific to the sample, adsorbent, and storage conditions, will guide choices in experimental and instrumental design to ensure that data from future field studies is reliable.
Collapse
|
19
|
Machine learning analysis of volatolomic profiles in breath can identify non-invasive biomarkers of liver disease: A pilot study. PLoS One 2021; 16:e0260098. [PMID: 34847181 PMCID: PMC8631657 DOI: 10.1371/journal.pone.0260098] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Accepted: 11/02/2021] [Indexed: 11/18/2022] Open
Abstract
Disease-related effects on hepatic metabolism can alter the composition of chemicals in the circulation and subsequently in breath. The presence of disease related alterations in exhaled volatile organic compounds could therefore provide a basis for non-invasive biomarkers of hepatic disease. This study examined the feasibility of using global volatolomic profiles from breath analysis in combination with supervised machine learning to develop signature pattern-based biomarkers for cirrhosis. Breath samples were analyzed using thermal desorption-gas chromatography-field asymmetric ion mobility spectroscopy to generate breathomic profiles. A standardized collection protocol and analysis pipeline was used to collect samples from 35 persons with cirrhosis, 4 with non-cirrhotic portal hypertension, and 11 healthy participants. Molecular features of interest were identified to determine their ability to classify cirrhosis or portal hypertension. A molecular feature score was derived that increased with the stage of cirrhosis and had an AUC of 0.78 for detection. Chromatographic breath profiles were utilized to generate machine learning-based classifiers. Algorithmic models could discriminate presence or stage of cirrhosis with a sensitivity of 88–92% and specificity of 75%. These results demonstrate the feasibility of volatolomic profiling to classify clinical phenotypes using global breath output. These studies will pave the way for the development of non-invasive biomarkers of liver disease based on volatolomic signatures found in breath.
Collapse
|
20
|
A multiple-method comparative study using GC-MS, AMDIS and in-house-built software for the detection and identification of "unknown" volatile organic compounds in breath. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4782. [PMID: 34523187 DOI: 10.1002/jms.4782] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 08/04/2021] [Accepted: 08/08/2021] [Indexed: 06/13/2023]
Abstract
The human respiratory system is a highly complex matrix that exhales many volatile organic compounds (VOCs). Breath-exhaled VOCs are often "unknowns" and possess low concentrations, which make their analysis, peak digging and data processing challenging. We report a new methodology, applied in a proof-of-concept experiment, for the detection of VOCs in breath. For this purpose, we developed and compared four complementary analysis methods based on solid-phase microextraction and thermal desorption (TD) tubes with two GC-mass spectrometer (MS) methods. Using eight model compounds, we obtained an LOD range of 0.02-20 ng/ml. We found that in breath analysis, sampling the exhausted air from Tedlar bags is better when TD tubes are used, not only because of the preconcentration but also due to the stability of analytes in the TD tubes. Data processing (peak picking) was based on two data retrieval approaches with an in-house script written for comparison and differentiation between two populations: sick and healthy. We found it best to use "raw" AMDIS deconvolution data (.ELU) rather than its NIST (.FIN) identification data for comparison between samples. A successful demonstration of this method was conducted in a pilot study (n = 21) that took place in a closed hospital ward (Covid-19 ward) with the discovery of four potential markers. These preliminary findings, at the molecular level, demonstrate the capabilities of our method and can be applied in larger and more comprehensive experiments in the omics world.
Collapse
|
21
|
Abstract
BACKGROUND There is a demand for a non-invasive bedside method to diagnose Acute Respiratory Distress Syndrome (ARDS). Octane was discovered and validated as the most important breath biomarker for diagnosis of ARDS using gas-chromatography and mass-spectrometry (GC-MS). However, GC-MS is unsuitable as a point-of-care (POC) test in the intensive care unit (ICU). Therefore, we determined if a newly developed POC breath test can reliably detect octane in exhaled breath of invasively ventilated ICU patients. METHODS Two developmental steps were taken to design a POC breath test that relies on gas-chromatography using air as carrier gas with a photoionization detector. Calibration measurements were performed with a laboratory prototype in healthy subjects. Subsequently, invasively ventilated patients were included for validation and assessment of repeatability. After evolving to a POC breath test, this device was validated in a second group of invasively ventilated patients. Octane concentration was based on the area under the curve, which was extracted from the chromatogram and compared to known values from calibration measurements. RESULTS Five healthy subjects and 53 invasively ventilated patients were included. Calibration showed a linear relation (R2 = 1.0) between the octane concentration and the quantified octane peak in the low parts per billion (ppb) range. For the POC breath test the repeatability was excellent (R2 = 0.98, ICC = 0.97 (95% CI 0.94-0.99)). CONCLUSION This is the first study to show that a POC breath test can rapidly and reliably detect octane, with excellent repeatability, at clinically relevant levels of low ppb in exhaled breath of ventilated ICU patients. This opens possibilities for targeted exhaled breath analysis to be used as a bedside test and makes it a potential diagnostic tool for the early detection of ARDS.
Collapse
|
22
|
A systematic review of the diagnostic accuracy of volatile organic compounds in airway diseases and their relation to markers of type-2 inflammation. ERJ Open Res 2021; 7:00030-2021. [PMID: 34476250 PMCID: PMC8405872 DOI: 10.1183/23120541.00030-2021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 03/27/2021] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Asthma and COPD continue to cause considerable diagnostic and treatment stratification challenges. Volatile organic compounds (VOCs) have been proposed as feasible diagnostic and monitoring biomarkers in airway diseases. AIMS To 1) conduct a systematic review evaluating the diagnostic accuracy of VOCs in diagnosing airway diseases; 2) understand the relationship between reported VOCs and biomarkers of type-2 inflammation; 3) assess the standardisation of reporting according to STARD and TRIPOD criteria; 4) review current methods of breath sampling and analysis. METHODS A PRISMA-oriented systematic search was conducted (January 1997 to December 2020). Search terms included: "asthma", "volatile organic compound(s)", "VOC" and "COPD". Two independent reviewers examined the extracted titles against review objectives. RESULTS 44 full-text papers were included; 40/44 studies were cross-sectional and four studies were interventional in design; 17/44 studies used sensor-array technologies (e.g. eNose). Cross-study comparison was not possible across identified studies due to the heterogeneity in design. The commonest airway diseases differentiating VOCs belonged to carbonyl-containing classes (i.e. aldehydes, esters and ketones) and hydrocarbons (i.e. alkanes and alkenes). Although individual markers that are associated with clinical biomarkers of type-2 inflammation were recognised (i.e. ethane and 3,7-dimethylnonane for asthma and α-methylstyrene and decane for COPD), these were not consistently identified across studies. Only 3/44 reported following STARD or TRIPOD criteria for diagnostic accuracy and multivariate reporting, respectively. CONCLUSIONS Breath VOCs show promise as diagnostic biomarkers of airway diseases and for type-2 inflammation profiling. However, future studies should focus on transparent reporting of diagnostic accuracy and multivariate models and continue to focus on chemical identification of volatile metabolites.
Collapse
|
23
|
A literature survey of all volatiles from healthy human breath and bodily fluids: the human volatilome. J Breath Res 2021; 15. [PMID: 33761469 DOI: 10.1088/1752-7163/abf1d0] [Citation(s) in RCA: 76] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 03/24/2021] [Indexed: 02/06/2023]
Abstract
This paper comprises an updated version of the 2014 review which reported 1846 volatile organic compounds (VOCs) identified from healthy humans. In total over 900 additional VOCs have been reported since the 2014 review and the VOCs from semen have been added. The numbers of VOCs found in breath and the other bodily fluids are: blood 379, breath 1488, faeces 443, milk 290, saliva 549, semen 196, skin 623 and urine 444. Compounds were assigned CAS registry numbers and named according to a common convention where possible. The compounds have been included in a single table with the source reference(s) for each VOC, an update on our 2014 paper. VOCs have also been grouped into tables according to their chemical class or functionality to permit easy comparison. Careful use of the database is needed, as a number of the identified VOCs only have level 2-putative assignment, and only a small fraction of the reported VOCs have been validated by standards. Some clear differences are observed, for instance, a lack of esters in urine with a high number in faeces and breath. However, the lack of compounds from matrices such a semen and milk compared to breath for example could be due to the techniques used or reflect the intensity of effort e.g. there are few publications on VOCs from milk and semen compared to a large number for breath. The large number of volatiles reported from skin is partly due to the methodologies used, e.g. by collecting skin sebum (with dissolved VOCs and semi VOCs) onto glass beads or cotton pads and then heating to a high temperature to desorb VOCs. All compounds have been included as reported (unless there was a clear discrepancy between name and chemical structure), but there may be some mistaken assignations arising from the original publications, particularly for isomers. It is the authors' intention that this work will not only be a useful database of VOCs listed in the literature but will stimulate further study of VOCs from healthy individuals; for example more work is required to confirm the identification of these VOCs adhering to the principles outlined in the metabolomics standards initiative. Establishing a list of volatiles emanating from healthy individuals and increased understanding of VOC metabolic pathways is an important step for differentiating between diseases using VOCs.
Collapse
|
24
|
Stability of volatile organic compounds in sorbent tubes following SARS-CoV-2 inactivation procedures. J Breath Res 2021; 15. [PMID: 33752195 DOI: 10.1088/1752-7163/abf0b4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 03/22/2021] [Indexed: 12/18/2022]
Abstract
COVID-19 is a highly transmissible respiratory illness that has rapidly spread all over the world causing more than 115 million cases and 2.5 million deaths. Most epidemiological projections estimate that the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) virus causing the infection will circulate in the next few years and raise enormous economic and social issues. COVID-19 has a dramatic impact on health care systems and patient management, and is delaying or stopping breath research activities due to the risk of infection to the operators following contact with patients, potentially infected samples or contaminated equipment. In this scenario, we investigated whether virus inactivation procedures, based on a thermal treatment (60 °C for 1 h) or storage of tubes at room temperature for 72 h, could be used to allow the routine breath analysis workflow to carry on with an optimal level of safety during the pandemic. Tests were carried out using dry and humid gaseous samples containing about 100 representative chemicals found in exhaled breath and ambient air. Samples were collected in commercially available sorbent tubes, i.e. Tenax GR and a combination of Tenax TA, Carbograph 1TD and Carboxen 1003. Our results showed that all compounds were stable at room temperature up to 72 h and that sample humidity was the key factor affecting the stability of the compounds upon thermal treatment. Tenax GR-based sorbent tubes were less impacted by the thermal treatment, showing variations in the range 20%-30% for most target analytes. A significant loss of aldehydes and sulphur compounds was observed using carbon molecular sieve-based tubes. In this case, a dry purge step before inactivation at 60 °C significantly reduced the loss of the target analytes, whose variations were comparable to the method variability. Finally, a breath analysis workflow including a SARS-CoV-2 inactivation treatment is proposed.
Collapse
|
25
|
Breath can discriminate tuberculosis from other lower respiratory illness in children. Sci Rep 2021; 11:2704. [PMID: 33526828 PMCID: PMC7851130 DOI: 10.1038/s41598-021-80970-w] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 12/28/2020] [Indexed: 01/30/2023] Open
Abstract
Pediatric tuberculosis (TB) remains a global health crisis. Despite progress, pediatric patients remain difficult to diagnose, with approximately half of all childhood TB patients lacking bacterial confirmation. In this pilot study (n = 31), we identify a 4-compound breathprint and subsequent machine learning model that accurately classifies children with confirmed TB (n = 10) from children with another lower respiratory tract infection (LRTI) (n = 10) with a sensitivity of 80% and specificity of 100% observed across cross validation folds. Importantly, we demonstrate that the breathprint identified an additional nine of eleven patients who had unconfirmed clinical TB and whose symptoms improved while treated for TB. While more work is necessary to validate the utility of using patient breath to diagnose pediatric TB, it shows promise as a triage instrument or paired as part of an aggregate diagnostic scheme.
Collapse
|
26
|
A stability study of carbonyl compounds in Tedlar bags by a fabricated MEMS microreactor approach. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
27
|
Data preprocessing workflow for exhaled breath analysis by GC/MS using open sources. Sci Rep 2020; 10:22008. [PMID: 33319832 PMCID: PMC7738550 DOI: 10.1038/s41598-020-79014-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 12/03/2020] [Indexed: 12/24/2022] Open
Abstract
The noninvasive diagnosis and monitoring of high prevalence diseases such as cardiovascular diseases, cancers and chronic respiratory diseases are currently priority objectives in the area of health. In this regard, the analysis of volatile organic compounds (VOCs) has been identified as a potential noninvasive tool for the diagnosis and surveillance of several diseases. Despite the advantages of this strategy, it is not yet a routine clinical tool. The lack of reproducible protocols for each step of the biomarker discovery phase is an obstacle of the current state. Specifically, this issue is present at the data preprocessing step. Thus, an open source workflow for preprocessing the data obtained by the analysis of exhaled breath samples using gas chromatography coupled with single quadrupole mass spectrometry (GC/MS) is presented in this paper. This workflow is based on the connection of two approaches to transform raw data into a useful matrix for statistical analysis. Moreover, this workflow includes matching compounds from breath samples with a spectral library. Three free packages (xcms, cliqueMS and eRah) written in the language R are used for this purpose. Furthermore, this paper presents a suitable protocol for exhaled breath sample collection from infants under 2 years of age for GC/MS.
Collapse
|
28
|
Use of the ReCIVA device in breath sampling of patients with acute breathlessness: a feasibility study. ERJ Open Res 2020; 6:00119-2020. [PMID: 33263021 PMCID: PMC7680907 DOI: 10.1183/23120541.00119-2020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Accepted: 07/17/2020] [Indexed: 01/24/2023] Open
Abstract
Introduction Investigating acute multifactorial undifferentiated breathlessness and understanding the driving inflammatory processes can be technically challenging in both adults and children. Being able to validate noninvasive methods such as breath analysis would be a huge clinical advance. The ReCIVA® device allows breath samples to be collected directly onto sorbent tubes at the bedside for analysis of exhaled volatile organic compounds (eVOCs). We aimed to assess the feasibility of using this device in acutely breathless patients. Methods Adults hospitalised with acute breathlessness and children aged 5–16 years with acute asthma or chronic stable asthma, as well as healthy adult and child volunteers, were recruited. Breath samples were collected onto sorbent tubes using the ReCIVA® device and sent for analysis by means of two-dimensional gas chromatography-mass spectrometry (GCxGC-MS). The NASA Task Load Index (NASA-TLX) was used to assess the perceived task workload of undertaking sampling from the patient's perspective. Results Data were available for 65 adults and 61 children recruited. In total, 98.4% of adults and 75.4% of children were able to provide the full target breath sample using the ReCIVA® device. NASA-TLX measurements were available in the adult population with mean values of 3.37 for effort, 2.34 for frustration, 3.8 for mental demand, 2.8 for performance, 3.9 for physical demand and 2.8 for temporal demand. Discussion This feasibility study demonstrates it is possible and acceptable to collect breath samples from both adults and children at the bedside for breathomics analysis using the ReCIVA® device. It is feasible to collect breath samples for breath analysis at the bedside using the ReCIVA device in acutely breathless adults and childrenhttps://bit.ly/2ZTonWo
Collapse
|
29
|
Impact of the adsorbent material on volatile metabolites during in vitro and in vivo bio-sampling. Talanta 2020; 222:121569. [PMID: 33167263 DOI: 10.1016/j.talanta.2020.121569] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 08/10/2020] [Accepted: 08/11/2020] [Indexed: 12/16/2022]
Abstract
The increased attraction of biological volatile compounds has opened the route to a wide variety of sampling techniques, amongst which trap tubes packed with adsorbent materials are commonly used. Many types of adsorbent materials are available and the choice of the adsorbent can impact the obtained results in untargeted analysis. Therefore, a proper combination of the adsorbent material and the sample is necessary to increase the robustness and reproducibility of biological studies. In this study, the sampling performance of thermal desorption tubes with six common adsorbent material combinations, i.e., Tenax® TA, Tenax® TA/Carbopack™ B, Tenax® TA/Sulficarb, Tenax® TA/Carbograph™ 5TD, Tenax® TA/Carbograph™ 1TD/Carboxen® 1003, and Carboxen® 1016/Carbograph™ 5TD, was evaluated in two different setups: in vitro and in vivo sampling. The in vitro setup consisted of the headspace dynamic extraction of spiked serum, and a mixture of 19 standards was evaluated in terms of response and reproducibility. The in vivo setup consisted into two parts: the first one was based the evaluation of the standard mixture, which was flash-vaporised into Tedlar® bags containing exhaled breath; the second part was based on the longitudinal monitoring of breath metabolites originating from a beverage intake (i.e., brewed coffee), over a 90 min time period. The tubes were all desorbed and analysed in a comprehensive two-dimensional gas chromatography system coupled to a high-resolution time-of-flight mass spectrometer (GC × GC-HR ToF MS). In both sampling setups, the widest analytes coverage and the overall best extraction yield on the selected compounds were obtained using Tenax® TA, followed by Tenax® TA/Carbopack™ B. Tenax® TA provided the highest sampling reproducibility with 12 %RSD, 10 %RSD and <5 %RSD of the response during the experiments using the in vitro setup, the in vivo setup, and during the longitudinal tracking, respectively.
Collapse
|
30
|
Effects of high relative humidity and dry purging on VOCs obtained during breath sampling on common sorbent tubes. J Breath Res 2020; 14:046006. [DOI: 10.1088/1752-7163/ab7e17] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
31
|
What smells? Developing in-field methods to characterize the chemical composition of wild mammalian scent cues. Ecol Evol 2020; 10:4691-4701. [PMID: 32551053 PMCID: PMC7297786 DOI: 10.1002/ece3.6224] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 02/18/2020] [Accepted: 03/02/2020] [Indexed: 01/04/2023] Open
Abstract
Olfactory cues play an important role in mammalian biology, but have been challenging to assess in the field. Current methods pose problematic issues with sample storage and transportation, limiting our ability to connect chemical variation in scents with relevant ecological and behavioral contexts. Real-time, in-field analysis via portable gas chromatography-mass spectrometry (GC-MS) has the potential to overcome these issues, but with trade-offs of reduced sensitivity and compound mass range. We field-tested the ability of portable GC-MS to support two representative applications of chemical ecology research with a wild arboreal primate, common marmoset monkeys (Callithrix jacchus). We developed methods to (a) evaluate the chemical composition of marmoset scent marks deposited at feeding sites and (b) characterize the scent profiles of exudates eaten by marmosets. We successfully collected marmoset scent marks across several canopy heights, with the portable GC-MS detecting known components of marmoset glandular secretions and differentiating these from in-field controls. Likewise, variation in the chemical profile of scent marks demonstrated a significant correlation with marmoset feeding behavior, indicating these scents' biological relevance. The portable GC-MS also delineated species-specific olfactory signatures of exudates fed on by marmosets. Despite the trade-offs, portable GC-MS represents a viable option for characterizing olfactory compounds used by wild mammals, yielding biologically relevant data. While the decision to adopt portable GC-MS will likely depend on site- and project-specific needs, our ability to conduct two example applications under relatively challenging field conditions bodes well for the versatility of in-field GC-MS.
Collapse
|
32
|
Evaluation of a standardized collection device for exhaled breath sampling onto thermal desorption tubes. J Breath Res 2020; 14:036004. [PMID: 32155613 DOI: 10.1088/1752-7163/ab7e3b] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The Respiration Collector for In Vitro Analysis (ReCIVA) sampler, marketed by Owlstone Medical, provides a step forward in exhaled breath sampling through active sampling directly onto thermal desorption (TD) tubes. Although an improvement to the issues surrounding breath bag sampling, the ReCIVA device, first released in 2015, is a relatively new research and clinical tool that requires further exploration. Here, data are presented comparing two distinct ReCIVA devices. The results, comparing ReCIVA serial numbers #33 and #65, demonstrate that overall statistically insignificant results are obtained via targeted isoprene quantitation (p > 0.05). However, when the data are parsed by the TD tube type used to capture breath volatiles, either Tenax TA or the dual bed Tenax/Carbograph 5TD (5TD), a statistical difference (p < 0.05) among the two different TD tubes was present. These data, comparing the two ReCIVA devices with both Tenax TA and 5TD tubes, are further supported by a global metabolomics analysis yielding 85% of z-scores, comparing ReCIVA devices, below the limit for significance. Experiments to determine the effect of breathing rate on ReCIVA function, using guided breathing for low (7.5 breaths min-1) and high (15 breaths min-1) breathing rates, demonstrate the ReCIVA device shows no statistical difference among breathing rates for quantitated isoprene (p > 0.05). Global metabolomics analysis of the guided breathing rate data shows more than 87% of the z-scores, comparing high and low breathing rates using both the Tenax and the 5TD tubes, are below the level for significance. Finally, data are provided from a single participant who displayed background levels of isoprene while illustrating levels of acetone consistent with the remaining participants. Collectively, these data support the use of multiple ReCIVA devices for exhaled breath collection and provide evidence for an instance where exhaled isoprene is consistent with background levels.
Collapse
|
33
|
Volatile organic compounds associated with diagnosis and disease characteristics in asthma - A systematic review. Respir Med 2020; 169:105984. [PMID: 32510334 DOI: 10.1016/j.rmed.2020.105984] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 03/30/2020] [Accepted: 04/19/2020] [Indexed: 12/16/2022]
Abstract
BACKGROUND Metabolomics refers to study of the metabolome, the entire set of metabolites produced by a biological system. The application of metabolomics to exhaled breath samples - breathomics - is a rapidly growing field with potential application to asthma diagnosis and management. OBJECTIVES We aimed to review the adult asthma breathomic literature and present a comprehensive list of volatile organic compounds identified by asthma breathomic models. METHODS We undertook a systematic search for literature on exhaled volatile organic compounds in adult asthma. We assessed the quality of studies and performed a qualitative synthesis. RESULTS We identified twenty studies; these were methodologically heterogenous with a variable risk of bias. Studies almost universally reported breathomics to be capable of differentiating - with moderate or greater accuracy - between samples from healthy controls and those with asthma; and to be capable of phenotyping disease. However, there was little concordance in the compounds upon which discriminatory models were based. CONCLUSION Results to-date are promising but validation in independent prospective cohorts is needed. This may be challenging given the high levels of inter-individual variation. However, large-scale, multi-centre studies are underway and validation efforts have been aided by the publication of technical standards likely to increase inter-study comparability. Successful validation of breathomic models for diagnosis and phenotyping would constitute an important step towards personalised medicine in asthma.
Collapse
|
34
|
Metabolomic study of volatile compounds emitted by lavender grown under open-field conditions: a potential approach to investigate the yellow decline disease. Metabolomics 2020; 16:31. [PMID: 32103392 DOI: 10.1007/s11306-020-01654-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2019] [Accepted: 02/19/2020] [Indexed: 01/09/2023]
Abstract
INTRODUCTION Fine lavender and lavandin are perfume and medicinal plants originate from the South of France and are widely cultivated for their essential oils. Recently, cultivated plants suffered from a severe decline in France, due to the propagation of the yellow decline disease. This disease is caused by the stolbur phytoplasma, a bacterium transmitted by a sap-sucking insect, the planthopper. OBJECTIVES In order to understand the complex relationships between host plant, pest, pathogen and environment responsible for the yellow decline of lavender, we use a metabolomic approach to highlight changes in chemical emissions from asymptomatic ("healthy") and symptomatic ("infected") plants. METHODS Volatile compounds produced by fine lavender and lavandin were collected in the field using a dynamic headspace extraction approach. Afterwards, compounds trapped on Tenax adsorbent were thermodesorbed and analysed using an automated thermal desorption-gas chromatography-mass spectrometry (ATD-GC-MS). Multivariate statistical analyses was performed using principal component analysis and partial least square discriminant analyses. RESULTS The untargeted screening of volatiles allowed the separation of asymptomatic and symptomatic plants according to their emissions. The approach was sufficiently accurate so as to separate the emissions according to the different stages of infection. Twelve compounds were found to be deregulated metabolites of yellow disease infection, common to fine lavender (variety 7713) and lavandin (variety abrial). CONCLUSION The metabolomic approach allowed for the effective identification of chemical variations between infected and healthy plants in a complex field environment.
Collapse
|
35
|
Abstract
Due to several sources of potential variability associated with exhaled breath bag sampling procedures for off-line analysis, the Respiration Collector for in vitro Analysis (ReCIVA) sampler was developed. Although designed to improve upon several pitfalls of sampling with exhaled breath bags, the ReCIVA remains a minimally studied research tool. In this manuscript, several attributes of the ReCIVA sampler are investigated among three individual tests, such as background contamination, control software version, performance of different adsorbent tubes, duplicate sample production, and comparison to exhaled breath bags. The data shows greater than a 58% reduction in background siloxanes can be achieved with submersion of ReCIVA masks in ethyl alcohol or baking the masks at a high temperature (200 °C). The results illustrate the ReCIVA control software version plays a key role in the flow rates applied to thermal desorption (TD) tubes. Using exhaled isoprene as a representative analyte, the data suggest duplicate samples among ReCIVA pump banks can be achieved using two different thermal desorption tubes, Tenax TA and Tenax/Carbograph 5TD, when using an updated control software and manually calibrating the ReCIVA pumps to uniform flow rates (Tenax p = 0.3869, 5TD p = 0.3131). Additionally, using the updated control software and manual ReCIVA flow calibration, the data suggest the ReCIVA can produce statistically similar results among TD tube types (p = 0.3824) and compared to standard exhaled breath bags (p = 0.1534). Collectively, these results establish a method for manually calibrating the flow of the ReCIVA device to allow for the most consistent results. These data support further experimentation into the use of the ReCIVA sampler for exhaled breath research.
Collapse
|
36
|
Using labelled internal standards to improve needle trap micro-extraction technique prior to gas chromatography/mass spectrometry. Talanta 2019; 200:145-155. [DOI: 10.1016/j.talanta.2019.03.046] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 03/08/2019] [Accepted: 03/11/2019] [Indexed: 12/18/2022]
|
37
|
Stability of Propofol (2,6-Diisopropylphenol) in Thermal Desorption Tubes during Air Transport. Int J Anal Chem 2019; 2019:3987417. [PMID: 31186644 PMCID: PMC6521560 DOI: 10.1155/2019/3987417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Accepted: 04/07/2019] [Indexed: 11/17/2022] Open
Abstract
The anesthetic propofol and other exhaled organic compounds can be sampled in Tenax sorbent tubes and analyzed by gas chromatography coupled with mass spectrometry. The aim of this study was to evaluate the stability of propofol in Tenax sorbent tubes during overseas shipping. This is relevant for international pharmacokinetic studies on propofol in exhaled air. Tenax sorbent tube propofol samples with concentrations between 10 and 100 ng were prepared by liquid injection and with a calibration gas generator. For each preparation method, one reference set was analyzed immediately after preparation, a second set was stored at room temperature, and a third one was stored refrigerated. The fourth set was sent from Germany by airmail to USA and back. The shipped set of tubes was analyzed when it returned after 55 days elapsed. Then, the room temperature samples and the refrigerated stored samples were also analyzed. To evaluate the stability of propofol in the stored and shipped tubes, we calculated the recovery rates of each sample set. The mean recovery in the stored samples was 101.2% for the liquid preparation and 134.6% for the gaseous preparation at 4°C. At 22°C, the recovery was 96.1% for liquid preparation and 92.1% for gaseous preparation, whereas the shipped samples had a recovery of 85.3% and 111.3%. Thus, the deviation of the shipped samples is within a range of 15%, which is analytically acceptable. However, the individual values show significantly larger deviations of up to -32.1% (liquid) and 30.9% (gaseous). We conclude that storage of propofol on Tenax tubes at room temperature for 55 days is possible to obtain acceptable results. However, it appears that due to severe temperature and pressure variations air shipment of propofol samples in Tenax tubes without cooling shows severe deviations from the initial concentration. Although it was not tested in this study, we assume that refrigerated transport might be necessary to obtain comparable results as in the stored samples.
Collapse
|
38
|
Stability control for breath analysis using GC-MS. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1097-1098:27-34. [PMID: 30199747 PMCID: PMC6167955 DOI: 10.1016/j.jchromb.2018.08.024] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 08/22/2018] [Accepted: 08/22/2018] [Indexed: 11/27/2022]
Abstract
Gas chromatography mass spectrometry (GC-MS) instruments provide researchers and clinicians with a vast amount of information on sample composition, thus these instruments are seen as gold standard in breath analysis research. However, there are many factors that can confound the data measured by GC-MS instruments. These factors will make interpretation of GC-MS data unreliable for breath analysis research. We present in this paper detailed studies of two of these factors: instrument variation over time and chemical degradation of known biomarkers during storage in sorbent tubes. We found that a single quadrupole MS showed larger variability in measurements than a quadrupole time-of-flight MS when the same mixture of chemical standards was analysed for a period of up to 8 weeks. We recommend procedures of normalising the data. Moreover, the stability studies of breath biomarkers like thioethers, previously found indicative of malaria, showed that there is a need to store the samples in sorbent tubes at low temperature, 6 °C, for no more than 20 days to avoid the total decay of the chemicals.
Collapse
|
39
|
High-Throughput Breath Volatile Organic Compound Analysis Using Thermal Desorption Proton Transfer Reaction Time-of-Flight Mass Spectrometry. Anal Chem 2018; 90:10204-10210. [DOI: 10.1021/acs.analchem.8b01045] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
40
|
Determination of carbonyl compounds in exhaled breath by on-sorbent derivatization coupled with thermal desorption and gas chromatography-tandem mass spectrometry. J Breath Res 2018; 12:046004. [DOI: 10.1088/1752-7163/aad202] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
41
|
Endogenous volatile organic compounds in acute myeloid leukemia: origins and potential clinical applications. J Breath Res 2018; 12:034002. [PMID: 29463782 DOI: 10.1088/1752-7163/aab108] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Not unlike many cancer types, acute myeloid leukemia (AML) exhibits many metabolic changes and reprogramming, causing changes in lipid metabolism. Some of the distinct molecular abnormalities associated with AML also modify the metabolic changes. Both processes result in changes in the production of endogenous volatile organic compounds (VOCs). The increasing availability of highly sensitive methods for detecting trace chemicals provides the opportunity to investigate the role of patient-specific VOC finger-prints as biomarkers for detecting early relapse or minimal residual disease in AML. Since VOC production is reliant on metabolic activities, when combined with currently available methods, VOC analysis may identify within a group of patients with flow cytometric or molecular evidence of residual disease those most at risk for disease relapse.
Collapse
|
42
|
Volatile metabolites in breath strongly correlate with gut microbiome in CD patients. Anal Chim Acta 2018; 1025:1-11. [PMID: 29801597 DOI: 10.1016/j.aca.2018.03.046] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Revised: 03/13/2018] [Accepted: 03/22/2018] [Indexed: 02/06/2023]
Abstract
Microbiota composition and its metabolic capacity are very important for host health. Evidence suggests that gut microbiome is involved in the metabolites production by host-microbiome interaction. These metabolites can be absorbed in blood and excreted in exhaled air. Although, profiles of gut microbiota and exhaled metabolites were associated with gastrointestinal diseases, a direct link between them has not yet been investigated. The aim of the study was to investigate the relation between volatiles in breath and gut microbiome in active and quiescent Crohn's disease (CD) via a multivariate statistical approach. Canonical correlation analysis (CCA) was used to assess the relation between exhaled metabolites and faecal bacterial species. From 68 CD patients, 184 repeated faecal and breath samples were collected (92 active and 92 quiescent disease). The microbiota composition was assessed by the pyrosequencing of the 16 S rRNA V1-V3 gene region and breath metabolites by gas chromatography mass spectrometry. In active disease, CCA analysis identified 18 metabolites significantly correlated with 19 faecal bacterial taxa (R = 0.91 p-value 3.5*10-4). In quiescent disease 17 volatile metabolites were correlated with 17 bacterial taxa (R = 0.96 p-value 2.8*10-4). Nine metabolites and three bacteria taxa overlapped in active and inactive CD. This is the first study that shows a significant relation between gut microbiome and exhaled metabolites, and was found to differ between active and quiescent CD, indicating various underlying mechanisms. Unravelling this link is essential to increase our understanding on the functional effects of the microbiome and may provide new leads for microbiome-targeted intervention.
Collapse
|
43
|
Diagnosis of acute respiratory distress syndrome by exhaled breath analysis. ANNALS OF TRANSLATIONAL MEDICINE 2018; 6:33. [PMID: 29430450 DOI: 10.21037/atm.2018.01.17] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The acute respiratory distress syndrome (ARDS) is a complication of critical illness that is characterized by acute onset, protein rich, pulmonary edema. There is no treatment for ARDS, other than the reduction of additional ventilator induced lung injury. Prediction or earlier recognition of ARDS could result in preventive measurements and might decrease mortality and morbidity. Exhaled breath contains volatile organic compounds (VOCs), a collection of hundreds of small molecules linked to several physiological and pathophysiological processes. Analysis of exhaled breath through gas-chromatography and mass-spectrometry (GC-MS) has resulted in an accurate diagnosis of ARDS in several studies. Most identified markers are linked to lipid peroxidation. Octane is one of the few markers that was validated as a marker of ARDS and is pathophysiologically likely to be increased in ARDS. None of the currently studied breath analysis methods is directly applicable in clinical practice. Two steps have to be taken before any breath test can be allowed into the intensive care unit. External validation in a multi-center study is a prerequisite for any of the candidate breath markers and the breath test should outperform clinical prediction scores. Second, the technology for breath analysis should be adapted so that it is available at a decentralized lab inside the intensive care unit and can be operated by trained nurses, in order to reduce the analysis time. In conclusion, exhaled analysis might be used for the early diagnosis and prediction of ARDS in the near future but several obstacles have to be taken in the coming years. Most of the candidate markers can be linked to lipid peroxidation. Only octane has been validated in a temporal external validation cohort and is, at this moment, the top-ranking breath biomarker for ARDS.
Collapse
|
44
|
|
45
|
On the importance of accurate quantification of individual volatile metabolites in exhaled breath. J Breath Res 2017. [PMID: 28635619 DOI: 10.1088/1752-7163/aa7ab5] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
It is argued that shortcomings of certain approaches to breath analysis research based on superficial interpretation of non-quantitative data are inadvertently inhibiting the progression of non-invasive breath analysis into clinical practice. The objective of this perspective is to suggest more clinically profitable approaches to breath research. Thus, following a discourse on the challenges and expectations in breath research, a brief indication is given of the analytical techniques currently used for the analysis of very humid exhaled breath. The seminal work that has been carried out using GC-MS revealed that exhaled breath comprises large numbers of trace volatile organic compounds, VOCs. Unfortunately, analysis of these valuable GC-MS data is mostly performed using chemometrics to distinguish the VOC content of breath samples collected from patients and healthy controls, and reliable quantification of the VOCs is rarely deemed necessary. This limited approach ignores the requirements of clinically acceptable biomarkers and misses the opportunity to identify relationships between the concentrations of individual VOCs and certain related physiological or metabolic parameters. Therefore, a plea is made for more effort to be directed towards the positive identification and accurate quantification of individual VOCs in exhaled breath, which are more physiologically meaningful as best exemplified by the quantification of breath nitric oxide, NO. Support for the value of individual VOC quantification is illustrated by the SIFT-MS studies of breath hydrogen cyanide, HCN, a biomarker of Pseudomonas aeruginosa infection, breath acetic acid as an indicator of airways acidification in cystic fibrosis patients, and n-pentane as a breath biomarker of inflammation in idiopathic bowel disease patients. These single VOCs could be used as non-invasive monitors of the efficacy of therapeutic intervention. The increase of breath methanol following the ingestion of a known amount of the sweetener aspartame impressively shows that accurate breath analysis is a reliable indicator of blood concentrations. However, using individual VOCs for specific disease diagnosis does have its problems and it is, perhaps, more appropriate to see their concentrations as proxy markers of general underlying physiological change. We dedicate this perspective to Lars Gustafsson for his seminal work on breath research and especially for his pioneering work on nitric oxide measurements in exhaled breath in asthma, which best shows the utility and value of the quantification of individual breath biomarkers on which this perspective focuses.
Collapse
|
46
|
Volatile Metabolites Emission by In Vivo Microalgae-An Overlooked Opportunity? Metabolites 2017; 7:E39. [PMID: 28788107 PMCID: PMC5618324 DOI: 10.3390/metabo7030039] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 07/19/2017] [Accepted: 07/25/2017] [Indexed: 01/04/2023] Open
Abstract
Fragrances and malodors are ubiquitous in the environment, arising from natural and artificial processes, by the generation of volatile organic compounds (VOCs). Although VOCs constitute only a fraction of the metabolites produced by an organism, the detection of VOCs has a broad range of civilian, industrial, military, medical, and national security applications. The VOC metabolic profile of an organism has been referred to as its 'volatilome' (or 'volatome') and the study of volatilome/volatome is characterized as 'volatilomics', a relatively new category in the 'omics' arena. There is considerable literature on VOCs extracted destructively from microalgae for applications such as food, natural products chemistry, and biofuels. VOC emissions from living (in vivo) microalgae too are being increasingly appreciated as potential real-time indicators of the organism's state of health (SoH) along with their contributions to the environment and ecology. This review summarizes VOC emissions from in vivo microalgae; tools and techniques for the collection, storage, transport, detection, and pattern analysis of VOC emissions; linking certain VOCs to biosynthetic/metabolic pathways; and the role of VOCs in microalgae growth, infochemical activities, predator-prey interactions, and general SoH.
Collapse
|
47
|
Abstract
BACKGROUND The potential of exhaled breath sampling and analysis has long attracted interest in the areas of medical diagnosis and disease monitoring. This interest is attributed to its non-invasive nature, access to an unlimited sample supply (i.e., breath), and the potential to facilitate a rapid at patient diagnosis. However, progress from laboratory setting to routine clinical practice has been slow. Different methodologies of breath sampling, and the consequent difficulty in comparing and combining data, are considered to be a major contributor to this. To fulfil the potential of breath analysis within clinical and pre-clinical medicine, standardisation of some approaches to breath sampling and analysis will be beneficial. OBJECTIVES The aim of this review is to investigate the heterogeneity of breath sampling methods by performing an in depth bibliometric search to identify the current state of art in the area. In addition, the review will discuss and critique various breath sampling methods for off-line breath analysis. METHODS Literature search was carried out in databases MEDLINE, BIOSIS, EMBASE, INSPEC, COMPENDEX, PQSCITECH, and SCISEARCH using the STN platform which delivers peer-reviewed articles. Keywords searched for include breath, sampling, collection, pre-concentration, volatile. Forward and reverse search was then performed on initially included articles. The breath collection methodologies of all included articles was subsequently reviewed. RESULTS Sampling methods differs between research groups, for example regarding the portion of breath being targeted. Definition of late expiratory breath varies between studies. CONCLUSIONS Breath analysis is an interdisciplinary field of study using clinical, analytical chemistry, data processing, and metabolomics expertise. A move towards standardisation in breath sampling is currently being promoted within the breath research community with a view to harmonising analysis and thereby increasing robustness and inter-laboratory comparisons.
Collapse
|