1
|
Köner Ö, Şimşek MA, Kızılcık N, Koca Ç, Cabbar AT. Remifentanil improves left ventricular diastolic parameters in patients with impaired diastolic function: a prospective clinical study. BMC Anesthesiol 2024; 24:45. [PMID: 38302904 PMCID: PMC10832159 DOI: 10.1186/s12871-024-02425-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 01/23/2024] [Indexed: 02/03/2024] Open
Abstract
BACKGROUND Left ventricular diastolic dysfunction has a significant impact on perioperative morbidity and mortality, and its incidence is high in elderly individuals. Anesthetic agents may impair diastolic function, which may increase the incidence of perioperative complications. The aim of this prospective, clinical, phase 4 study was to investigate the effects of remifentanil on left ventricle (LV) diastolic function in patients with diastolic dysfunction. The study was performed on 30 spontaneously breathing subjects (aged 60-80 years) with diastolic dysfunction. METHODS Thirty patients (aged 60-80 years) with diastolic dysfunction scheduled for surgery were recruited between November 2019 and March 2023. Left ventricle function was evaluated once the intravenous remifentanil infusion reached a target-controlled concentration of 2 ng/ml with transthoracic echocardiography. Analysis of systolic function focused on left ventricular ejection fraction and mean mitral annular S velocity (Sm), whereas diastolic function focused on changes in transmitral peak flow (E), E/A, mitral septal and lateral e' waves, E/e' ratios and left atrial volume index following remifentanil infusion. RESULTS Diastolic function measures of LV (mitral E/e', septal and lateral e' waves) statistically significantly improved (E/e' from 10.6 ± 2.9 cm.sn- 1 to 9.5 ± 2.2 cm.sn- 1; p = 0.006) following remifentanil infusion. Left atrial volume index decreased following remifentanil infusion without statistical significance (from 55 ± 14.4 ml.cm- 2 to 51.6 ± 13.3 ml.cm- 2; p = 0.1). Systolic function (ejection fraction and Sm) did not change following remifentanil infusion. CONCLUSIONS Remifentanil improves left ventricular diastolic parameters in patients with preexisting diastolic dysfunction. Our study suggests that remifentanil at a plasma concentration of 2 ng.ml- 1 might be used safely in patients with left ventricular diastolic dysfunction.
Collapse
Affiliation(s)
- Özge Köner
- Anesthesiology Department, Yeditepe University Medical Faculty, Istanbul, Türkiye.
| | | | - Nurcan Kızılcık
- Anesthesiology Department, Yeditepe University Medical Faculty, Istanbul, Türkiye
| | - Çiğdem Koca
- Cardiology Department, Yeditepe University Medical Faculty, Istanbul, Türkiye
| | - Ayça Türer Cabbar
- Cardiology Department, Yeditepe University Medical Faculty, Istanbul, Türkiye
| |
Collapse
|
2
|
Braithwaite HE, Payne T, Duce N, Lim J, McCulloch T, Loadsman J, Leslie K, Webster AC, Gaskell A, Sanders RD. Impact of female sex on anaesthetic awareness, depth, and emergence: a systematic review and meta-analysis. Br J Anaesth 2023; 131:510-522. [PMID: 37453840 DOI: 10.1016/j.bja.2023.06.042] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 05/30/2023] [Accepted: 06/01/2023] [Indexed: 07/18/2023] Open
Abstract
BACKGROUND Suggested anaesthetic dose ranges do not differ by sex, likely because of limited studies comparing sexes. Our objective was to systematically synthesise studies with outcomes of unintended anaesthesia awareness under anaesthesia, intraoperative connected consciousness, time to emergence from anaesthesia, and dosing to achieve adequate depth of anaesthesia, and to compare between females and males. METHODS Studies were identified from MEDLINE, Embase, and the Cochrane library databases until August 2, 2022. Controlled clinical trials (randomised/non-randomised) and prospective cohort studies that reported outcomes by sex were included. Results were synthesised by random effects meta-analysis where possible, or narrative form. RESULTS Of the 19 749 studies identified, 64 (98 243 participants; 53 143 females and 45 100 males) were eligible for inclusion, and 44 citations contributed to meta-analysis. Females had a higher incidence of awareness with postoperative recall (33 studies, odds ratio 1.38, 95% confidence interval [CI] 1.09-1.75) and connected consciousness during anaesthesia (three studies, OR 2.09, 95% CI 1.04-4.23) than males. Time to emergence was faster in females, including time to eye-opening (10 studies, mean difference -2.28 min, 95% CI -3.58 to -0.98), and time to response to command (six studies, mean difference -2.84 min, 95% CI -4.07 to -1.62). Data on depth of anaesthesia were heterogenous, limiting synthesis to a qualitative review which did not identify sex differences. CONCLUSIONS Female sex was associated with a greater incidence of awareness under general anaesthesia, and faster emergence from anaesthesia. These data suggest reappraisal of anaesthetic care, including whether similar drug dosing for females and males represents best care. SYSTEMATIC REVIEW REGISTRATION PROSPERO CRD42022336087.
Collapse
Affiliation(s)
- Hannah E Braithwaite
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney Local Health District, NSW, Australia.
| | - Thomas Payne
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney Local Health District, NSW, Australia; Central Clinical School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
| | - Nicholas Duce
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney Local Health District, NSW, Australia
| | - Jessica Lim
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney Local Health District, NSW, Australia
| | - Tim McCulloch
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney Local Health District, NSW, Australia
| | - John Loadsman
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney Local Health District, NSW, Australia
| | - Kate Leslie
- Department of Critical Care, Melbourne Medical School, University of Melbourne, Melbourne, VIC, Australia; Central Clinical School, Faculty of Medicine, Dentistry and Health Sciences, Monash University, Melbourne, VIC, Australia; Department of Anaesthesia and Pain Management, Royal Melbourne Hospital, Parkville, VIC, Australia
| | - Angela C Webster
- Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia; Centre for Transplant and Renal Research, Westmead Hospital, Sydney, NSW, Australia; National Health and Medical Research Council Clinical Trials Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
| | - Amy Gaskell
- Department of Anaesthesiology, Waikato Clinical Campus, University of Auckland, Hamilton, New Zealand
| | - Robert D Sanders
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney Local Health District, NSW, Australia; Central Clinical School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia; Institute of Academic Surgery, Royal Prince Alfred Hospital, Sydney Local Health District, NSW, Australia; National Health and Medical Research Council Clinical Trials Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
3
|
Karer G, Škrjanc I. Improved Individualized Patient-Oriented Depth-of-Hypnosis Measurement Based on Bispectral Index. SENSORS (BASEL, SWITZERLAND) 2022; 23:293. [PMID: 36616891 PMCID: PMC9824030 DOI: 10.3390/s23010293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 12/21/2022] [Accepted: 12/22/2022] [Indexed: 06/17/2023]
Abstract
Total intravenous anesthesia is an anesthesiologic technique where all substances are injected intravenously. The main task of the anesthesiologist is to assess the depth of anesthesia, or, more specifically, the depth of hypnosis (DoH), and accordingly adjust the dose of intravenous anesthetic agents. However, it is not possible to directly measure the anesthetic agent concentrations or the DoH, so the anesthesiologist must rely on various vital signs and EEG-based measurements, such as the bispectral (BIS) index. The ability to better measure DoH is directly applicable in clinical practice-it improves the anesthesiologist's assessment of the patient state regarding anesthetic agent concentrations and, consequently, the effects, as well as provides the basis for closed-loop control algorithms. This article introduces a novel structure for modeling DoH, which employs a residual dynamic model. The improved model can take into account the patient's individual sensitivity to the anesthetic agent, which is not the case when using the available population-data-based models. The improved model was tested using real clinical data. The results show that the predictions of the BIS-index trajectory were improved considerably. The proposed model thus seems to provide a good basis for a more patient-oriented individualized assessment of DoH, which should lead to better administration methods that will relieve the anesthesiologist's workload and will benefit the patient by providing improved safety, individualized treatment, and, thus, alleviation of possible adverse effects during and after surgery.
Collapse
|
4
|
Sex and Age Influence on Association of CYP450 Polymorphism with Midazolam Levels in Critically Ill Children. Diagnostics (Basel) 2022; 12:diagnostics12112797. [PMID: 36428856 PMCID: PMC9689687 DOI: 10.3390/diagnostics12112797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/04/2022] [Accepted: 11/09/2022] [Indexed: 11/18/2022] Open
Abstract
Midazolam is a drug that is metabolized by cytochrome P450 (CYP450) enzymes, particularly CYP3A4 and CYP3A5. The present study aimed to determine the sex and age influence on association of CYP450 polymorphism with midazolam levels in critically ill children. Seventy-two DNA samples were genotyped by real-time PCR. Children ≤ five years of age who carry the rs776746 (T) allele in CYP3A5 gene were associated with lower plasma midazolam levels. The concentration median in patients was 0.0 ng/mL, while in patients with the normal (C) allele, it was 438.17 ng/mL (Q25 135.75-Q75 580.24), p = 0.005. The midazolam plasmatic concentration in female patients with the minor (T) allele was 0.0 ng/mL (Q250.00-Q75204.3), while in patients with the normal (C) allele median it was 459.0 ng/mL (Q25296.9-Q75789.7), p = 0.002. Analysis of the dominant model for the rs2740574 variant in CYP3A4 revealed a median of 0.38 L/kg (Q250.02-Q751.5) for the volume of distribution parameter in female patients with the normal T allele, while female patients with the minor C allele showed a median of 18.1 L/kg (Q257.5-Q7528.7) p = 0.02. Our results suggest an altered midazolam metabolism due to the presence the allelic rs2740574 variants of CYP3A4 and rs776746 of CYP3A5, and also the strong influence of age and sex.
Collapse
|
5
|
Scherrer V, Lamoureux F, Chaventre C, Thill C, Demailly Z, Selim J, Bauer F, Imbert L, Wurtz V, Compère V, Clavier T, Besnier E. Reliability of the Minto model for target-controlled infusion of remifentanil during cardiac surgery with cardiopulmonary bypass. Br J Anaesth 2022; 129:163-171. [PMID: 35750514 DOI: 10.1016/j.bja.2022.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 05/03/2022] [Accepted: 05/06/2022] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND The Minto pharmacokinetic model is used for target-controlled infusion of remifentanil. The reliability of this model has never been evaluated during normothermic cardiac surgery with cardiopulmonary bypass (CPB). The aim of this study was to assess the predictive performance of the model during CPB to determine its reliability during cardiac surgery. METHODS This was a single-centre observational study. Arterial blood samples were drawn at five time points: T1, after tracheal intubation; T2, immediately before CPB; T3, 10 min after starting CPB; T4, 45 min after starting CPB; T5, 10 min after weaning off CPB. Prediction error (PE) and absolute prediction error (APE) were calculated for each sample and used to determine median prediction error (MDPE) and median absolute prediction error (MDAPE) per patient. Risk factors for APE >30% were assessed using multivariable analysis. Results are presented as medians with inter-quartile ranges. RESULTS Fifty-eight patients with 283 blood samples (110 during CPB) were included. In the pre-CPB period, MDPE and MDAPE were -17.3 [-32.9 to 2.3] and 24.6 [12-37.7]%, whereas during CPB, they were -1.8 [-15.6 to 11.1] and 14.0 [6.74-27.1]%, respectively. There was no statistically significant difference between measured and predicted remifentanil plasma concentrations during CPB. Age, preoperative albumin concentrations, temperature, and haemodilution were not independently associated with MDAPE >30%. CONCLUSIONS The Minto model accurately predicts plasma remifentanil concentrations during cardiac surgery with CPB. CLINICAL TRIAL REGISTRATION 2017-A03153-50.
Collapse
Affiliation(s)
- Vincent Scherrer
- Rouen University Hospital, Department of Anaesthesiology and Critical Care, Rouen, France
| | - Fabien Lamoureux
- Rouen University Hospital, Department of Pharmacology, Rouen, France; Normandie Univ, UNIROUEN, Inserm U1096, EnVi, Rouen, France
| | - Céline Chaventre
- Rouen University Hospital, Department of Anaesthesiology and Critical Care, Rouen, France
| | - Caroline Thill
- Rouen University Hospital, Department of Biostatistics, Rouen, France
| | - Zoe Demailly
- Rouen University Hospital, Department of Anaesthesiology and Critical Care, Rouen, France; Normandie Univ, UNIROUEN, Inserm U1096, EnVi, Rouen, France
| | - Jean Selim
- Rouen University Hospital, Department of Anaesthesiology and Critical Care, Rouen, France; Normandie Univ, UNIROUEN, Inserm U1096, EnVi, Rouen, France
| | - Fabrice Bauer
- Normandie Univ, UNIROUEN, Inserm U1096, EnVi, Rouen, France; Rouen University Hospital, Department of Cardiac Surgery, Rouen, France
| | - Laurent Imbert
- Rouen University Hospital, Department of Pharmacology, Rouen, France
| | - Véronique Wurtz
- Rouen University Hospital, Department of Anaesthesiology and Critical Care, Rouen, France
| | - Vincent Compère
- Rouen University Hospital, Department of Anaesthesiology and Critical Care, Rouen, France; Normandie Univ, UNIROUEN, INSERM U1239, Rouen, France
| | - Thomas Clavier
- Rouen University Hospital, Department of Anaesthesiology and Critical Care, Rouen, France; Normandie Univ, UNIROUEN, Inserm U1096, EnVi, Rouen, France
| | - Emmanuel Besnier
- Rouen University Hospital, Department of Anaesthesiology and Critical Care, Rouen, France; Normandie Univ, UNIROUEN, Inserm U1096, EnVi, Rouen, France.
| |
Collapse
|
6
|
Joksimovic SM, Sampath D, Krishnan K, Covey DF, Jevtovic-Todorovic V, Raol YH, Todorovic SM. Differential effects of the novel neurosteroid hypnotic (3β,5β,17β)-3-hydroxyandrostane-17-carbonitrile on electroencephalogram activity in male and female rats. Br J Anaesth 2021; 127:435-446. [PMID: 33972091 PMCID: PMC8451239 DOI: 10.1016/j.bja.2021.03.029] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 03/01/2021] [Accepted: 03/03/2021] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND We recently showed that a neurosteroid analogue, (3β,5β,17β)-3-hydroxyandrostane-17-carbonitrile (3β-OH), induced hypnosis in rats. The aim of the present study was to evaluate the hypnotic and anaesthetic potential of 3β-OH further using electroencephalography. METHODS We used behavioural assessment and cortical electroencephalogram (EEG) spectral power analysis to examine hypnotic and anaesthetic effects of 3β-OH (30 and 60 mg kg-1) administered intraperitoneally or intravenously to young adult male and female rats. RESULTS We found dose-dependent sex differences in 3β-OH-induced hypnosis and EEG changes. Both male and female rats responded similarly to i.p. 3β-OH 30 mg kg-1. However, at the higher dose (60 mg kg-1, i.p.), female rats had two-fold longer duration of spontaneous immobility than male rats (203.4 [61.6] min vs 101.3 [32.1] min), and their EEG was suppressed in the low-frequency range (2-6 Hz), in contrast to male rats. Although a sex-dependent hypnotic effect was not confirmed after 30 mg kg-1 i.v., female rats appeared more sensitive to 3β-OH with relatively small changes within delta (1-4 Hz) and alpha (8-13 Hz) bands. Finally, 3β-OH had a rapid onset of action and potent hypnotic/anaesthetic effect after 60 mg kg-1 i.v. in rats of both sexes; however, all female rats and only half of the male rats reached burst suppression, an EEG pattern usually associated with profound inhibition of thalamocortical networks. CONCLUSIONS Based on its behavioural effects and EEG signature, 3β-OH is a potent hypnotic in rats, with female rats being more sensitive than male rats.
Collapse
Affiliation(s)
- Srdjan M Joksimovic
- Department of Anesthesiology, University of Colorado Denver, Anschutz Medical Campus, Aurora, CO, USA.
| | - Dayalan Sampath
- Department of Neuroscience and Experimental Therapeutics, Texas A&M University System, College Station, TX, USA
| | - Kathiresan Krishnan
- Department of Developmental Biology, Washington University School of Medicine, St Louis, MO, USA
| | - Douglas F Covey
- Department of Developmental Biology, Washington University School of Medicine, St Louis, MO, USA; Taylor Family Institute for Innovative Psychiatric Research, Washington University School of Medicine, St Louis, MO, USA
| | - Vesna Jevtovic-Todorovic
- Department of Anesthesiology, University of Colorado Denver, Anschutz Medical Campus, Aurora, CO, USA
| | - Yogendra H Raol
- Department of Pediatrics, Division of Neurology, Translational Epilepsy Research Program, University of Colorado Denver, Anschutz Medical Campus, Aurora, CO, USA
| | - Slobodan M Todorovic
- Department of Anesthesiology, University of Colorado Denver, Anschutz Medical Campus, Aurora, CO, USA; Neuroscience Graduate Program, University of Colorado Denver, Anschutz Medical Campus, Aurora, CO, USA
| |
Collapse
|
7
|
Giuffrida M, Ledingham NS, Machi P, Czarnetzki CA. Rapid arousal from anaesthesia after reversal of deep rocuronium-induced neuromuscular block with sugammadex in a neuroradiological procedure. BMJ Case Rep 2021; 14:14/8/e242820. [PMID: 34417232 PMCID: PMC8382267 DOI: 10.1136/bcr-2021-242820] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
We describe the case of a 42-year-old man undergoing elective embolisation of an arteriovenous malformation at the level of the right posterior cerebral artery under propofol anaesthesia. We used the SedLine Brain Function Monitor (Masimo) to titrate the anaesthetic depth with propofol. At the end of the procedure, the patient aroused from anaesthesia very rapidly after the reversal of deep neuromuscular block with sugammadex, despite still significant calculated doses of propofol at the effect site. This rapid arousal was monitored using the SedLine Brain Function Monitor.
Collapse
Affiliation(s)
- Matteo Giuffrida
- Division of Anaesthesiology, Department of Anaesthesiology, Intensive care and Emergency Medecine, Ente Ospedaliero Cantonale, Lugano, Switzerland
| | - Nicola Susan Ledingham
- Division of Anaesthesiology, Department of Anaesthesiology, Intensive care and Emergency Medecine, Ente Ospedaliero Cantonale, Lugano, Switzerland
| | - Paolo Machi
- Division of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland
| | - Christoph Andreas Czarnetzki
- Division of Anaesthesiology, Department of Anaesthesiology, Intensive care and Emergency Medecine, Ente Ospedaliero Cantonale, Lugano, Switzerland .,Division of Anaesthesiology, Geneva University Hospitals, Geneva, Switzerland.,Faculty of Medecine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
8
|
Li R, Yang L, Guan S, Lin M, Lai H, Liu K, Liu Z, Zhang X. UPLC-MS-Based Serum Metabolic Profiling Reveals Potential Biomarkers for Predicting Propofol Responsiveness in Females. J Proteome Res 2021; 20:4578-4588. [PMID: 34384217 DOI: 10.1021/acs.jproteome.1c00554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Although previous studies have shown that certain factors interfere with the sensitivity of propofol, the mechanisms for interindividual variability in response to propofol remain unclear. This study aimed to screen the metabolites to predict patients' sensitivity to propofol and to identify metabolic pathways to explore possible mechanisms associated with propofol resistance. Sera from 40 female patients undergoing elective hysteroscopic surgery in a prospective cohort propofol study were obtained before the administration of propofol. The patients' responsiveness to propofol was differentiated based on propofol effect-site concentration. Serum samples from two sets, a discovery set (n = 24) and an independent validation set (n = 16), were analyzed using ultraperformance liquid chromatography coupled with mass spectrometry based untargeted metabolomics. In the discovery set, 494 differential metabolites were screened out, and then 391 potential candidate biomarkers with the area under receiver operating characteristic curve >0.80 were selected. Pathway analysis showed that the pathway of glycerophospholipid metabolism was the most influential pathway. In the independent validation set, six potential biomarkers enabled the discrimination of poor responders from good and intermediate responders, which might be applied to predict propofol sensitivity. The mass spectrometry data are available via MetaboLights (http://www.ebi.ac.uk/metabolights/login) with the identifier MTBLS2311.
Collapse
Affiliation(s)
- Ruiyun Li
- Department of Anesthesiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China
| | - Lu Yang
- Department of Anesthesiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China
| | - Su Guan
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou 510006, China
| | - Ming Lin
- Department of Anesthesiology, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou 510120, China
| | - Hanjin Lai
- Department of Critical Care Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China
| | - Kun Liu
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou 510006, China
| | - Zimeng Liu
- Department of Critical Care Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China
| | - Xuyu Zhang
- Department of Anesthesiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China
| |
Collapse
|
9
|
Dahaba AA, Xiao Z, Zhu X, Oettl K, Dong H, Xiong L, Zelzer S, Zhao S, Reibnegger G. Location matters: Overlooked ethnic-geographic effect in China and Austria on propofol/cisatracurium sex differences among a population pharmacokinetic/pharmacodynamic (PopPK/PD) covariate analysis in men, women, and one transgender subject. Fundam Clin Pharmacol 2021; 36:182-198. [PMID: 34050969 DOI: 10.1111/fcp.12704] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Accepted: 05/26/2021] [Indexed: 11/29/2022]
Abstract
A quick literature search using "sex/gender" vs. the commonly used hypnotic propofol or neuromuscular-blocking agent cisatracurium will reveal numerous contradictory sex difference publications depending on the ethnic-geographic location of where these studies were conducted. We induced anesthesia with cisatracurium besylate (GlaxoSmithKline) 100 μg kg-1 administered exactly 1 minute following propofol (AstraZeneca) 2 mg kg-1 . In 20 male and 20 female ethnic Han-Chinese test set patients (Xi'an China), and in similar ethnic white Austrian validation set patients (Graz Austria), we quantified propofol/cisatracurium pharmacodynamic parameters namely propofol onset time, lag time, plasma concentrations (Cp ) at loss-of-behavioral response (LOBR) using bispectral index (BIS); cisatracurium onset time, lag time, and Cp at T1 % (first twitch of train-of-four) complete twitch suppression using mechanomyography (MMG). Serial arterial blood samples were collected for population pharmacokinetic (PopPK) analysis of all demographic and biological covariates (region, sex, age, weight, and height) versus volumes of distribution and clearances pharmacokinetic parameters. In Chinese women (but not in white women), propofol Cp at LOBR was 33.60% lower than men and cisatracurium Cp at T1 % complete twitch suppression was 21.49% lower than men, a clear pharmacodynamic assertion. Region and weight were significant PopPK covariates. We demonstrated that sex differences are influenced by ethnic-geographic location as only in Chinese women (but not in white women) propofol Cp at LOBR and cisatracurium Cp at T1 % complete twitch suppression were lower than in men. When defining sex differences, ethnic-geographic location should be taken into consideration as a predictive factor for optimizing propofol/cisatracurium initial loading recommended dosages.
Collapse
Affiliation(s)
- Ashraf A Dahaba
- Department of Anaesthesiology and Intensive Care Medicine, Suez Canal University, Ismailia, Egypt
| | - Zhaoyang Xiao
- Department of Anesthesiology, Xijing Hospital of Fourth Military Medical University, Xi'an, Shanxi, China.,Department of Anesthesiology, Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Xiaoling Zhu
- Department of Anesthesiology, Xijing Hospital of Fourth Military Medical University, Xi'an, Shanxi, China
| | - Karl Oettl
- Otto-Loewi Research Center for Physiological Chemistry, Medical University of Graz, Graz, Austria
| | - Hailong Dong
- Department of Anesthesiology, Xijing Hospital of Fourth Military Medical University, Xi'an, Shanxi, China
| | - Lize Xiong
- Department of Anesthesiology, Xijing Hospital of Fourth Military Medical University, Xi'an, Shanxi, China
| | - Sieglinde Zelzer
- Institute for Medical and Chemical Diagnostics, Medical University of Graz, Graz, Austria
| | - Shuiyu Zhao
- Shanghai Qiangshi Information Technology Co. Ltd, Shanghai, China
| | - Gilbert Reibnegger
- Otto-Loewi Research Center for Physiological Chemistry, Medical University of Graz, Graz, Austria
| |
Collapse
|
10
|
Abstract
Propofol is an intravenous hypnotic drug that is used for induction and maintenance of sedation and general anaesthesia. It exerts its effects through potentiation of the inhibitory neurotransmitter γ-aminobutyric acid (GABA) at the GABAA receptor, and has gained widespread use due to its favourable drug effect profile. The main adverse effects are disturbances in cardiopulmonary physiology. Due to its narrow therapeutic margin, propofol should only be administered by practitioners trained and experienced in providing general anaesthesia. Many pharmacokinetic (PK) and pharmacodynamic (PD) models for propofol exist. Some are used to inform drug dosing guidelines, and some are also implemented in so-called target-controlled infusion devices, to calculate the infusion rates required for user-defined target plasma or effect-site concentrations. Most of the models were designed for use in a specific and well-defined patient category. However, models applicable in a more general population have recently been developed and published. The most recent example is the general purpose propofol model developed by Eleveld and colleagues. Retrospective predictive performance evaluations show that this model performs as well as, or even better than, PK models developed for specific populations, such as adults, children or the obese; however, prospective evaluation of the model is still required. Propofol undergoes extensive PK and PD interactions with both other hypnotic drugs and opioids. PD interactions are the most clinically significant, and, with other hypnotics, tend to be additive, whereas interactions with opioids tend to be highly synergistic. Response surface modelling provides a tool to gain understanding and explore these complex interactions. Visual displays illustrating the effect of these interactions in real time can aid clinicians in optimal drug dosing while minimizing adverse effects. In this review, we provide an overview of the PK and PD of propofol in order to refresh readers' knowledge of its clinical applications, while discussing the main avenues of research where significant recent advances have been made.
Collapse
Affiliation(s)
- Marko M. Sahinovic
- Department of Anaesthesiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
- University Medical Center Groningen, Hanzeplein 1, PO Box 30.001, 9700 RB Groningen, The Netherlands
| | - Michel M. R. F. Struys
- Department of Anaesthesiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
- Department of Anaesthesia and Peri-Operative Medicine, Ghent University, Ghent, Belgium
| | - Anthony R. Absalom
- Department of Anaesthesiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
| |
Collapse
|
11
|
van den Berg JP, Vereecke HEM, Proost JH, Eleveld DJ, Wietasch JKG, Absalom AR, Struys MMRF. Pharmacokinetic and pharmacodynamic interactions in anaesthesia. A review of current knowledge and how it can be used to optimize anaesthetic drug administration. Br J Anaesth 2018; 118:44-57. [PMID: 28039241 DOI: 10.1093/bja/aew312] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
This review describes the basics of pharmacokinetic and pharmacodynamic drug interactions and methodological points of particular interest when designing drug interaction studies. It also provides an overview of the available literature concerning interactions, with emphasis on graphic representation of interactions using isoboles and response surface models. It gives examples on how to transform this knowledge into clinically and educationally applicable (bedside) tools.
Collapse
Affiliation(s)
- J P van den Berg
- Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - H E M Vereecke
- Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - J H Proost
- Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - D J Eleveld
- Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - J K G Wietasch
- Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - A R Absalom
- Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - M M R F Struys
- Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
12
|
Impact of clinical factors and UGT1A9 and CYP2B6 genotype on inter-individual differences in propofol pharmacokinetics. J Anesth 2018; 32:236-243. [PMID: 29468507 DOI: 10.1007/s00540-018-2470-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Accepted: 02/17/2018] [Indexed: 12/23/2022]
Abstract
PURPOSE Propofol is one of the most widely used fast-acting intravenously administered anesthetics. However, although large inter-individual differences in dose requirements and recovery time have been observed, there are few previous studies in which the association between several potential covariates, including genetic factors such as the UGT1A9 and CYP2B6 genotypes, and propofol pharmacokinetics was simultaneously examined. This study aimed to identify factors determining propofol pharmacokinetics. METHODS Eighty-three patients were enrolled, and their blood samples were collected 1, 5, 10, and 15 min after administering a single intravenous bolus of propofol at a dose of 2.0 ml/kg to measure propofol plasma concentration. Area under the time-plasma concentration curve from zero up to the last measurable time point (AUC15min) was determined from the concentration data. The inter-individual variability of the propofol pharmacokinetics was evaluated by investigating relationships between AUC15min and genotype of UGT1A9 and CYP2B6; clinical factors, such as age, sex, body mass index (BMI), and preoperative hematological examination; and hemodynamic variables measured by a pulse dye densitogram analyzer. The Spearman rank correlation coefficient and the Mann-Whitney U test were used for the statistical analysis of continuous and categorical values, respectively. Subsequently, clinical factors that had p values of < 0.05 in the univariate analysis were examined in a multivariate analysis using multiple linear regression analysis. RESULTS Age, BMI, indocyanine green disappearance ratio (K-ICG), hepatic blood flow (HBF), preoperative hemoglobin level, and sex were correlated with AUC15min (p < 0.05) in univariate analysis. Multivariate analysis performed to adjust for age, BMI, K-ICG, HBF, preoperative hemoglobin level, and sex revealed only BMI as an independent factor associated with AUC15min. CONCLUSIONS This study demonstrated that BMI influences propofol pharmacokinetics after its administration as a single intravenous injection, while UGT1A9 and CYP2B6 SNPs, other clinical factors, and hemodynamic variables do not. These results suggest that BMI is an independent factor associated with propofol pharmacokinetics in several potential covariates. CLINICAL TRIALS REGISTRATION NUMBER University Hospital Medical Information Network (UMIN000022948).
Collapse
|
13
|
Han MM, Xue FS, Kang F, Huang X, Li J. Male requires a higher median target effect-site concentration of propofol for I-gel placement when combined with dexmedetomidine. Anaesth Crit Care Pain Med 2018; 38:57-61. [PMID: 29452333 DOI: 10.1016/j.accpm.2018.01.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 12/10/2017] [Accepted: 01/21/2018] [Indexed: 11/28/2022]
Abstract
OBJECTIVE The supraglottic airway device (SAD) can be used for airway management of spontaneous breathing patients, and propofol is commonly applied for the SAD placement. This study was designed to assess the effect of gender on median target effect-site concentration (Ce50) of propofol for I-gel placement when combined with dexmedetomidine. MATERIAL AND METHOD 19 males and 18 females, aged 18 to 59 and undergoing elective surgery, were enrolled. After intravenous infusion of dexmedetomidine 1.0μg/kg over 10min followed by continuous infusion of 0.4μg/kg/h, target-controlled infusion of propofol under Marsh model was started and the initial Ce of propofol was set at 4.79μg/mL and 4.35μg/mL in the male and female patients, respectively. The I-gel was inserted when the Ce of propofol reached the pre-set concentration and bispectral index value was less than 60. The Ce of propofol required for I-gel placement was determined by the Dixon up-and-down method. RESULTS The Ce50 (95% confidence interval) of propofol required for I-gel placement were 4.082μg/mL (3.798-4.332μg/mL) and 3.509μg/mL (3.266-3.749μg/mL) in male and female patients, respectively, with a significantly higher Ce50 in males. CONCLUSION When combined with dexmedetomidine, males require a higher Ce50 of propofol for I-gel placement compared to females.
Collapse
Affiliation(s)
- M-M Han
- Department of Anaesthesiology, Anhui Provincial Hospital, Anhui Medical University, Hefei, China.
| | - F-S Xue
- Department of Anaesthesiology, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| | - F Kang
- Department of Anaesthesiology, Anhui Provincial Hospital, Anhui Medical University, Hefei, China.
| | - X Huang
- Department of Anaesthesiology, Anhui Provincial Hospital, Anhui Medical University, Hefei, China.
| | - J Li
- Department of Anaesthesiology, Anhui Provincial Hospital, Anhui Medical University, Hefei, China.
| |
Collapse
|
14
|
Cortegiani A, Pavan A, Azzeri F, Accurso G, Vitale F, Gregoretti C. Precision and Bias of Target‐Controlled Prolonged Propofol Infusion for General Anesthesia and Sedation in Neurosurgical Patients. J Clin Pharmacol 2018; 58:606-612. [DOI: 10.1002/jcph.1060] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2017] [Accepted: 11/16/2017] [Indexed: 12/15/2022]
Affiliation(s)
- Andrea Cortegiani
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anesthesia Analgesia Intensive Care and Emergency, Policlinico Paolo Giaccone, University of Palermo Palermo Italy
| | - Alessandra Pavan
- Anestesia e Rianimazione Ospedale Civico di Chivasso Asl TO4 Chivasso Italy
| | | | | | - Filippo Vitale
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anesthesia Analgesia Intensive Care and Emergency, Policlinico Paolo Giaccone, University of Palermo Palermo Italy
| | - Cesare Gregoretti
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anesthesia Analgesia Intensive Care and Emergency, Policlinico Paolo Giaccone, University of Palermo Palermo Italy
| |
Collapse
|
15
|
Changes in transcranial motor evoked potentials during hemorrhage are associated with increased serum propofol concentrations. J Clin Monit Comput 2017; 32:541-548. [DOI: 10.1007/s10877-017-0057-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2017] [Accepted: 08/19/2017] [Indexed: 10/19/2022]
|
16
|
Liu SH, Tian M. Factors affecting recovery from anaesthesia with propofol-remifentanil target-controlled infusion in laparoscopic surgery. J Int Med Res 2017; 45:1007-1014. [PMID: 28534702 PMCID: PMC5536417 DOI: 10.1177/0300060517705539] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Objective This study was performed to analyse factors influencing the effect-site concentration (Ce) of propofol at return of consciousness (ROC) with target-controlled infusion of propofol–remifentanil after laparoscopic surgery. Methods In total, 112 patients who underwent laparoscopic surgery under general anaesthesia were given propofol at the target concentration of 3.5 µg/ml. Remifentanil (Ce: 4.0 ng/ml) and 0.9 mg/kg of rocuronium were administered when the Observer’s Assessment of Alertness/Sedation score reached 1. Two minutes after injection of rocuronium, tracheal intubation was initiated. The bispectral index (BIS) was maintained between 45 and 55. Results Ce values of propofol at loss of consciousness (LOC) and ROC were significantly correlated. Age was significantly correlated with Ce of propofol at ROC. At LOC, propofol Ce values of patients aged 65–80, 45–64, and 20–44 years were 1.8 ± 0.8, 2.2 ± 0.7, and 2.3 ± 0.8 µg/ml, respectively, and the BIS was 70 ± 10, 68 ± 7, and 69 ± 10, respectively. At ROC, the propofol Ce values of the three groups were 1.2 ± 0.3, 1.4 ± 0.3, and 1.5 ± 0.3 µg/ml, respectively, and the BIS was 80 ± 5, 82 ± 6, and 83 ± 6, respectively. Conclusions The concentration of propofol at ROC was significantly affected by age, and ROC of propofol–remifentanil anaesthesia after laparoscopic surgery was well predicted by the concentration at LOC.
Collapse
Affiliation(s)
- Shao-Hua Liu
- Beijing Friendship Hospital, Capital Medical University, Beijing, PR China
| | - Ming Tian
- Beijing Friendship Hospital, Capital Medical University, Beijing, PR China
| |
Collapse
|
17
|
Trefz P, Kamysek S, Fuchs P, Sukul P, Schubert JK, Miekisch W. Drug detection in breath: non-invasive assessment of illicit or pharmaceutical drugs. J Breath Res 2017; 11:024001. [DOI: 10.1088/1752-7163/aa61bf] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
18
|
Wang X, Zhou Q, Jiang D, Gong Y, Li E, Li H. Ion mobility spectrometry as a simple and rapid method to measure the plasma propofol concentrations for intravenous anaesthesia monitoring. Sci Rep 2016; 6:37525. [PMID: 27869199 PMCID: PMC5116632 DOI: 10.1038/srep37525] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Accepted: 10/31/2016] [Indexed: 01/04/2023] Open
Abstract
The plasma propofol concentration is important information for anaesthetists to monitor and adjust the anaesthesia depth for patients during a surgery operation. In this paper, a stand-alone ion mobility spectrometer (IMS) was constructed for the rapid measurement of the plasma propofol concentrations. Without any sample pre-treatment, the plasma samples were dropped on a piece of glass microfiber paper and then introduced into the IMS cell by the thermal desorption directly. Each individual measurement could be accomplished within 1 min. For the plasma propofol concentrations from 1 to 12 μg mL-1, the IMS response was linear with a correlation coefficient R2 of 0.998, while the limit of detection was evaluated to be 0.1 μg mL-1. These measurement results did meet the clinical application requirements. Furthermore, other clinically-often-used drugs, including remifentanil, flurbiprofen and atracurium, were found no significant interference with the qualitative and quantitative analysis of the plasma propofol. The plasma propofol concentrations measured by IMS were correlated well with those measured by the high performance liquid chromatography (HPLC). The results confirmed an excellent agreement between these two methods. Finally, this method was applied to monitor the plasma propofol concentrations for a patient undergoing surgery, demonstrating its capability of anaesthesia monitoring in real clinical environments.
Collapse
Affiliation(s)
- Xin Wang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, 116023, People's Republic of China
| | - Qinghua Zhou
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, 116023, People's Republic of China
| | - Dandan Jiang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, 116023, People's Republic of China
| | - Yulei Gong
- Department of Anesthesiology, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, 150001, People's Republic of China
| | - Enyou Li
- Department of Anesthesiology, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, 150001, People's Republic of China
| | - Haiyang Li
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, 116023, People's Republic of China
| |
Collapse
|
19
|
Messina AG, Wang M, Ward MJ, Wilker CC, Smith BB, Vezina DP, Pace NL. Anaesthetic interventions for prevention of awareness during surgery. Cochrane Database Syst Rev 2016; 10:CD007272. [PMID: 27755648 PMCID: PMC6461159 DOI: 10.1002/14651858.cd007272.pub2] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND General anaesthesia is usually associated with unconsciousness. 'Awareness' is when patients have postoperative recall of events or experiences during surgery. 'Wakefulness' is when patients become conscious during surgery, but have no postoperative recollection of the period of consciousness. OBJECTIVES To evaluate the efficacy of two types of anaesthetic interventions in reducing clinically significant awareness:- anaesthetic drug regimens; and- intraoperative anaesthetic depth monitors. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL, ISSUE 4 2016); PubMed from 1950 to April 2016; MEDLINE from 1950 to April 2016; and Embase from 1980 to April 2016. We contacted experts to identify additional studies. We performed a handsearch of the citations in the review. We did not search trial registries. SELECTION CRITERIA We included randomized controlled trials (RCTs) of either anaesthetic regimens or anaesthetic depth monitors. We excluded volunteer studies, studies of patients prior to skin incision, intensive care unit studies, and studies that only randomized different word presentations for memory tests (not anaesthetic interventions).Anaesthetic drug regimens included studies of induction or maintenance, or both. Anaesthetic depth monitors included the Bispectral Index monitor, M-Entropy, Narcotrend monitor, cerebral function monitor, cerebral state monitor, patient state index, and lower oesophageal contractility monitor. The use of anaesthetic depth monitors allows the titration of anaesthetic drugs to maintain unconsciousness. DATA COLLECTION AND ANALYSIS At least two authors independently scanned abstracts, extracted data from the studies, and evaluated studies for risk of bias. We made attempts to contact all authors for additional clarification. We performed meta-analysis statistics in packages of the R language. MAIN RESULTS We included 160 studies with 54,109 enrolled participants; 53,713 participants started the studies and 50,034 completed the studies or data analysis (or both). We could not use 115 RCTs in meta-analytic comparisons because they had zero awareness events. We did not merge 27 of the remaining 45 studies because they had excessive clinical and methodological heterogeneity. We pooled the remaining 18 eligible RCTs in meta-analysis. There are 10 studies awaiting classification which we will process when we update the review.The meta-analyses included 18 trials with 36,034 participants. In the analysis of anaesthetic depth monitoring (either Bispectral Index or M-entropy) versus standard clinical and electronic monitoring, there were nine trials with 34,744 participants. The overall event rate was 0.5%. The effect favoured neither anaesthetic depth monitoring nor standard clinical and electronic monitoring, with little precision in the odds ratio (OR) estimate (OR 0.98, 95% confidence interval (CI) 0.59 to 1.62).In a five-study subset of Bispectral Index monitoring versus standard clinical and electronic monitoring, with 34,181 participants, 503 participants gave awareness reports to a blinded, expert panel who adjudicated or judged the outcome for each patient after reviewing the questionnaires: no awareness, possible awareness, or definite awareness. Experts judged 351 patient awareness reports to have no awareness, 87 to have possible awareness, and 65 to have definite awareness. The effect size favoured neither Bispectral Index monitoring nor standard clinical and electronic monitoring, with little precision in the OR estimate for the combination of definite and possible awareness (OR 0.96, 95% CI 0.35 to 2.65). The effect size favoured Bispectral Index monitoring for definite awareness, but with little precision in the OR estimate (OR 0.60, 95% CI 0.13 to 2.75).We performed three smaller meta-analyses of anaesthetic drugs. There were nine studies with 1290 participants. Wakefulness was reduced by ketamine and etomidate compared to thiopental. Wakefulness was more frequent than awareness. Benzodiazepines reduces awareness compared to thiopental, ketamine, and placebo., Also, higher doses of inhaled anaesthetics versus lower doses reduced the risk of awareness.We graded the quality of the evidence as low or very low in the 'Summary of findings' tables for the five comparisons.Most of the secondary outcomes in this review were not reported in the included RCTs. AUTHORS' CONCLUSIONS Anaesthetic depth monitors may have similar effects to standard clinical and electrical monitoring on the risk of awareness during surgery. In older studies comparing anaesthetics in a smaller portion of the patient sample, wakefulness occurred more frequently than awareness. Use of etomidate and ketamine lowered the risk of wakefulness compared to thiopental. Benzodiazepines compared to thiopental and ketamine, or higher doses of inhaled anaesthetics versus lower doses, reduced the risk of awareness.
Collapse
Affiliation(s)
- Anthony G Messina
- School of Management, University of Texas at DallasThe Alliance for Medical Management EducationBox 2331920 N. Coit RoadRichardsonTXUSA75080
| | - Michael Wang
- University of LeicesterClinical Psychology UnitLancaster RoadLeicesterUKLE1 7HA
| | - Marshall J Ward
- Dartmouth‐Hitchcock Medical Center1 Medical Center DrLebanonNHUSA03766
| | - Chase C Wilker
- ARUP LaboratoriesClinical Toxicology IIISalt Lake CityUTUSA
| | - Brett B Smith
- University of UtahUniversity of Utah School of MedicineSalt Lake CityUTUSA84112
| | - Daniel P Vezina
- University of UtahDepartment of Anesthesiology, Department of Internal Medicine, Division of CardiologySalt Lake CityUTUSA
- Veteran's AdministrationEchocardiography LaboratorySalt Lake CityUTUSA
| | - Nathan Leon Pace
- University of UtahDepartment of Anesthesiology3C444 SOM30 North 1900 EastSalt Lake CityUTUSA84132‐2304
| | | |
Collapse
|
20
|
Kenwright DA, Bernjak A, Draegni T, Dzeroski S, Entwistle M, Horvat M, Kvandal P, Landsverk SA, McClintock PVE, Musizza B, Petrovčič J, Raeder J, Sheppard LW, Smith AF, Stankovski T, Stefanovska A. The discriminatory value of cardiorespiratory interactions in distinguishing awake from anaesthetised states: a randomised observational study. Anaesthesia 2015; 70:1356-68. [PMID: 26350998 PMCID: PMC4989441 DOI: 10.1111/anae.13208] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/09/2015] [Indexed: 12/20/2022]
Abstract
Depth of anaesthesia monitors usually analyse cerebral function with or without other physiological signals; non‐invasive monitoring of the measured cardiorespiratory signals alone would offer a simple, practical alternative. We aimed to investigate whether such signals, analysed with novel, non‐linear dynamic methods, would distinguish between the awake and anaesthetised states. We recorded ECG, respiration, skin temperature, pulse and skin conductivity before and during general anaesthesia in 27 subjects in good cardiovascular health, randomly allocated to receive propofol or sevoflurane. Mean values, variability and dynamic interactions were determined. Respiratory rate (p = 0.0002), skin conductivity (p = 0.03) and skin temperature (p = 0.00006) changed with sevoflurane, and skin temperature (p = 0.0005) with propofol. Pulse transit time increased by 17% with sevoflurane (p = 0.02) and 11% with propofol (p = 0.007). Sevoflurane reduced the wavelet energy of heart (p = 0.0004) and respiratory (p = 0.02) rate variability at all frequencies, whereas propofol decreased only the heart rate variability below 0.021 Hz (p < 0.05). The phase coherence was reduced by both agents at frequencies below 0.145 Hz (p < 0.05), whereas the cardiorespiratory synchronisation time was increased (p < 0.05). A classification analysis based on an optimal set of discriminatory parameters distinguished with 95% success between the awake and anaesthetised states. We suggest that these results can contribute to the design of new monitors of anaesthetic depth based on cardiovascular signals alone.
Collapse
Affiliation(s)
| | | | - T Draegni
- Oslo University Hospital, Ullevaal, Norway
| | - S Dzeroski
- Jožef Stefan Institute, Ljubljana, Slovenia
| | | | - M Horvat
- Faculty of Mathematics and Physics, University of Ljubljana, Ljubljana, Slovenia
| | - P Kvandal
- Oslo University Hospital, Ullevaal, Norway
| | | | | | - B Musizza
- Jožef Stefan Institute, Ljubljana, Slovenia
| | | | - J Raeder
- Oslo University Hospital, Ullevaal, Norway
| | | | - A F Smith
- Royal Lancaster Infirmary, Lancaster, UK
| | | | | |
Collapse
|
21
|
Subramanian A, Wanta BT, Fogelson JL, Curry TB, Hannon JD. Time to extubation during propofol anesthesia for spine surgery with sufentanil compared with fentanyl: a retrospective cohort study. Spine (Phila Pa 1976) 2014; 39:1758-64. [PMID: 25010093 DOI: 10.1097/brs.0000000000000509] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Retrospective cohort study. OBJECTIVE This study compares time to extubation between major spine surgery patients anesthetized with fentanyl versus sufentanil infusions in combination with propofol. SUMMARY OF BACKGROUND DATA In patients undergoing spinal fusion with intraoperative electrophysiological monitoring of the spinal cord, total intravenous anesthesia with a propofol/opioid combination results in better electrophysiological signals compared with volatile anesthetics. Pharmacokinetic data suggest that total intravenous anesthesia with sufentanil should lead to more rapid emergence from anesthesia than with fentanyl. However, this has never been tested in the spine surgery patient population. METHODS With institutional review board approval, all major spine patients receiving a propofol-based total intravenous anesthesia with fentanyl were compared with those receiving sufentanil. Time to extubation, defined as the time from surgical closure to tracheal extubation, was the study outcome. Relevant demographic, anthropomorphic, anesthetic, and surgical data were collected. Association between type of opioid and time to extubation was tested for statistical significance. Multiple linear regression analysis was used to control for confounders. RESULTS A total of 167 patients met inclusion criteria (fentanyl = 72, sufentanil = 95). There was no statistically significant difference between the 2 groups in terms of baseline characteristics. Time from surgical closure to extubation in the fentanyl versus sufentanil groups was not statistically different (mean [SD]: 40.2 [26.7] min vs. 45.0 [36.9] min; P = 0.36). On multivariate analysis, total dose of propofol and male sex were associated with increased time to extubation. CONCLUSION The use of sufentanil may not reduce time to extubation compared with fentanyl despite its favorable pharmacokinetic profile. Higher doses of propofol and male sex were associated with longer time to extubation and seem to play a greater role than choice of opioid. LEVEL OF EVIDENCE 3.
Collapse
Affiliation(s)
- Arun Subramanian
- Departments of *Anesthesiology and †Neurosurgery, Mayo Clinic Rochester, Rochester, MN
| | | | | | | | | |
Collapse
|
22
|
Eleveld DJ, Proost JH, Cortínez LI, Absalom AR, Struys MMRF. A general purpose pharmacokinetic model for propofol. Anesth Analg 2014; 118:1221-37. [PMID: 24722258 DOI: 10.1213/ane.0000000000000165] [Citation(s) in RCA: 131] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Pharmacokinetic (PK) models are used to predict drug concentrations for infusion regimens for intraoperative displays and to calculate infusion rates in target-controlled infusion systems. For propofol, the PK models available in the literature were mostly developed from particular patient groups or anesthetic techniques, and there is uncertainty of the accuracy of the models under differing patient and clinical conditions. Our goal was to determine a PK model with robust predictive performance for a wide range of patient groups and clinical conditions. METHODS We aggregated and analyzed 21 previously published propofol datasets containing data from young children, children, adults, elderly, and obese individuals. A 3-compartmental allometric model was estimated with NONMEM software using weight, age, sex, and patient status as covariates. A predictive performance metric focused on intraoperative conditions was devised and used along with the Akaike information criteria to guide model development. RESULTS The dataset contains 10,927 drug concentration observations from 660 individuals (age range 0.25-88 years; weight range 5.2-160 kg). The final model uses weight, age, sex, and patient versus healthy volunteer as covariates. Parameter estimates for a 35-year, 70-kg male patient were: 9.77, 29.0, 134 L, 1.53, 1.42, and 0.608 L/min for V1, V2, V3, CL, Q2, and Q3, respectively. Predictive performance is better than or similar to that of specialized models, even for the subpopulations on which those models were derived. CONCLUSIONS We have developed a single propofol PK model that performed well for a wide range of patient groups and clinical conditions. Further prospective evaluation of the model is needed.
Collapse
Affiliation(s)
- Douglas J Eleveld
- From the *Department of Anesthesiology, University Medical Center Groningen, University of Groningen, The Netherlands; †Departmento de Anestesiología, Escuela de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile; and ‡Department of Anesthesia, Ghent University, Gent, Belgium
| | | | | | | | | |
Collapse
|
23
|
Parida S, Badhe AS. Comparison of cognitive, ambulatory, and psychomotor recovery profiles after day care anesthesia with propofol and sevoflurane. J Anesth 2014; 28:833-8. [PMID: 24748400 DOI: 10.1007/s00540-014-1827-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2013] [Accepted: 03/25/2014] [Indexed: 11/25/2022]
Abstract
PURPOSE We compared the recovery profile of propofol and sevoflurane when used for maintenance of anesthesia in elective day care operative procedures. METHODS One hundred ASA physical status I and II patients, aged between 18 and 50 years, were randomly assigned to receive either propofol-nitrous oxide or sevoflurane-nitrous oxide maintenance of anesthesia. Early and intermediate recovery in terms of cognitive and ambulatory functions was recorded. Psychomotor testing, in the form of Trieger dot test and digit symbol substitution test, were performed before surgery and in the post-anesthesia care unit at 15 min, 30 min, 1 h, 2 h, and 4 h following nitrous oxide switch-off to evaluate intermediate recovery. RESULTS There were no significant differences in recovery of early cognitive functions between the two groups, except that patients in the sevoflurane group were more responsive at around 10 min following nitrous oxide switch-off and "recalled address" earlier than patients in the propofol group. There was no significant difference in between the two groups with regard to "home-readiness." CONCLUSIONS Recovery from sevoflurane anesthesia, especially with regard to cognitive functions, may be slightly faster than from propofol, but the difference is not sufficiently significant to affect the time to "home-readiness" in patients undergoing day care surgery.
Collapse
Affiliation(s)
- Satyen Parida
- Department of Anesthesiology and Critical Care, Qr. No. D(II) 18, JIPMER Campus, Dhanvantari Nagar, Puducherry, 605006, India,
| | | |
Collapse
|
24
|
Assessment of the performance of the Marsh model in effect site mode for target controlled infusion of propofol during the maintenance phase of general anaesthesia in an unselected population of neurosurgical patients. Eur J Anaesthesiol 2013; 30:627-32. [DOI: 10.1097/eja.0b013e328363157a] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
25
|
Choong E, Loryan I, Lindqvist M, Nordling Å, el Bouazzaoui S, van Schaik RH, Johansson I, Jakobsson J, Ingelman-Sundberg M. Sex Difference in Formation of Propofol Metabolites: A Replication Study. Basic Clin Pharmacol Toxicol 2013; 113:126-31. [DOI: 10.1111/bcpt.12070] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2013] [Accepted: 03/07/2013] [Indexed: 11/29/2022]
Affiliation(s)
- Eva Choong
- Section of Pharmacogenetics; Department of Physiology and Pharmacology; Karolinska Institutet; Stockholm; Sweden
| | - Irena Loryan
- Section of Pharmacogenetics; Department of Physiology and Pharmacology; Karolinska Institutet; Stockholm; Sweden
| | - Marja Lindqvist
- Section of Pharmacogenetics; Department of Physiology and Pharmacology; Karolinska Institutet; Stockholm; Sweden
| | - Åsa Nordling
- Section of Pharmacogenetics; Department of Physiology and Pharmacology; Karolinska Institutet; Stockholm; Sweden
| | - Samira el Bouazzaoui
- Department of Clinical Chemistry; Erasmus MC Rotterdam; Rotterdam; The Netherlands
| | - Ron H. van Schaik
- Department of Clinical Chemistry; Erasmus MC Rotterdam; Rotterdam; The Netherlands
| | - Inger Johansson
- Section of Pharmacogenetics; Department of Physiology and Pharmacology; Karolinska Institutet; Stockholm; Sweden
| | - Jan Jakobsson
- Section of Pharmacogenetics; Department of Physiology and Pharmacology; Karolinska Institutet; Stockholm; Sweden
| | - Magnus Ingelman-Sundberg
- Section of Pharmacogenetics; Department of Physiology and Pharmacology; Karolinska Institutet; Stockholm; Sweden
| |
Collapse
|
26
|
Abstract
The influence of sex and gender on anesthesia and analgesic therapy remains poorly understood, nevertheless the numerous physiological and pharmacological differences present between men and women. Although in anesthesiology sex-gender aspects have attracted little attention, it has been reported that women have a greater sensitivity to the non-depolarizing neuroblocking agents, whereas males are more sensitive than females to propofol. It has been suggested that men wake slower than women after general anesthesia and have less postoperative nausea and vomiting. Sexual hormones seem to be of importance in the onset of differences. Nevertheless, in the last years, sex-gender influences on pain and analgesia have become a hot topic and data regarding sex-gender differences in response to pharmacologic and non-pharmacologic pain treatments are still scanty, inconsistent, and non-univocal. In particular, females seem to be more sensitive than males to opioid receptor agonists. Women may experience respiratory depression and other adverse effects more easily if they are given the same doses as males. Evidently, there is an obvious need for more research, which should include psychological and social factors in experimental preclinical and clinical paradigms in view of their importance on pain mechanism, in order to individualize analgesia to optimize pain relief.
Collapse
Affiliation(s)
- Ilaria Campesi
- Department of Biomedical Sciences, University of Sassari, Sassari, Italy
| | | | | |
Collapse
|
27
|
Gender-specific differences in the central nervous system's response to anesthesia. Transl Stroke Res 2012; 4:462-75. [PMID: 24323342 DOI: 10.1007/s12975-012-0229-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2012] [Accepted: 11/12/2012] [Indexed: 12/17/2022]
Abstract
Males and females are physiologically distinct in their responses to various anesthetic agents. The brain and central nervous system (CNS), the main target of anesthesia, are sexually dimorphic from birth and continue to differentiate throughout life. Accordingly, gender has a substantial impact on the influence of various anesthetic agents in the brain and CNS. Given the vast differences in the male and female CNS, it is surprising to find that females are often excluded from basic and clinical research studies of anesthesia. In animal research, males are typically studied to avoid the complication of breeding, pregnancy, and hormonal changes in females. In clinical studies, females are also excluded for the variations that occur in the reproductive cycle. Being that approximately half of the surgical population is female, the exclusion of females in anesthesia-related research studies leaves a huge knowledge gap in the literature. In this review, we examine the reported sex-specific differences in the central nervous system's response to anesthesia. Furthermore, we suggest that anesthesia researchers perform experiments on both sexes to further evaluate such differences. We believe a key goal of research studying the interaction of the brain and anesthesia should include the search for knowledge of sex-specific mechanisms that will improve anesthetic care and management in both sexes.
Collapse
|
28
|
Bienert A, Wiczling P, Grześkowiak E, Cywiński JB, Kusza K. Potential pitfalls of propofol target controlled infusion delivery related to its pharmacokinetics and pharmacodynamics. Pharmacol Rep 2012; 64:782-95. [DOI: 10.1016/s1734-1140(12)70874-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2011] [Revised: 04/05/2012] [Indexed: 10/25/2022]
|
29
|
Cowley NJ, Laitenberger P, Liu B, Jarvis J, Clutton-Brock TH. Evaluation of a new analyser for rapid measurement of blood propofol concentration during cardiac surgery. Anaesthesia 2012; 67:870-4. [DOI: 10.1111/j.1365-2044.2012.07151.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
30
|
Sneyd JR. Depth-of-anaesthesia monitoring. SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA 2012. [DOI: 10.1080/22201173.2012.10872820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
31
|
Buchanan F, Myles P, Cicuttini F. Effect of patient sex on general anaesthesia and recovery. Br J Anaesth 2011; 106:832-9. [DOI: 10.1093/bja/aer094] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
|
32
|
Bolliger D, Seeberger M, Kasper J, Skarvan K, Seeberger E, Lurati Buse G, Buser P, Filipovic M. Remifentanil does not impair left ventricular systolic and diastolic function in young healthy patients. Br J Anaesth 2011; 106:573-9. [DOI: 10.1093/bja/aeq414] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
33
|
Jung SM, Yang CW, Oh JY, Cho CK, Kang PS, Lim YS, Jeong SJ, Kwon HU. Predicted effect-site concentration of propofol and sufentanil for gynecological laparoscopic surgery. Acta Anaesthesiol Scand 2011; 55:110-7. [PMID: 21039351 DOI: 10.1111/j.1399-6576.2010.02327.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND this study was to estimate the predicted effect-site concentration of propofol administered by a target-controlled infusion (TCI) for maintenance of anesthesia based on the bispectral (BIS) index as a measure of hypnosis in laparoscopic surgery. METHOD one-hundred and sixty unpremedicated patients undergoing gynecologic laparoscopy were assigned randomly to receive one of the target effect-site concentrations of propofol 2.0, 2.5, 3.0, 3.5 and 4.0 microg/ml during TCI with propofol and sufentanil. The dose-response relationship of propofol for the maintenance of adequate anesthesia based on BIS, movement and hemodynamic response was investigated using a fixed effect-site concentration of sufentanil (0.2 ng/ml). The BIS values, hemodynamic variables, time course during emergence and intraoperative awareness were also assessed. RESULTS the predicted effect-site propofol concentrations for adequate anesthesia at the skin incision in 50% (EC(50) ) and 95% (EC(95) ) of patients undergoing gynecologic laparoscopy were 2.2 and 3.7 microg/ml, respectively. The predicted propofol EC(50) and EC(95) to maintain adequate anesthesia in these patients were 2.6 microg/ml (95% CI 2.3-2.7 microg/ml) and 3.6 microg/ml (95% CI 3.3-4.0 microg/ml), respectively. The BIS values, effect-site concentration of propofol, hemodynamic data and time course during emergence and post-operative adverse events were comparable in each group. There were no reports of intraoperative awareness in the post-anesthetic care unit. CONCLUSION based on the anesthetic depth assessed by the clinical signs and BIS monitoring, the predicted effect-site propofol concentrations for the maintenance of anesthesia in patients undergoing gynecologic laparoscopy were similar in those administered adequate anesthesia at the skin incision during TCI.
Collapse
Affiliation(s)
- S M Jung
- Department of Anesthesiology and Pain Medicine, School of Medicine, Konyang University Hospital, Daejeon, Korea Department of Anesthesiology and Pain Medicine, School of Medicine, Inha University Hospital, Incheon, Korea
| | | | | | | | | | | | | | | |
Collapse
|
34
|
Kennedy RR. Individualising Target-Controlled Anaesthesia. Better Models or Better Targets? Anaesth Intensive Care 2010; 38:421-3. [DOI: 10.1177/0310057x1003800302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
35
|
Kirkebøen KA, Lindholm E, Raeder J. [Choice of anaesthetic approach and anaesthetic drugs]. TIDSSKRIFT FOR DEN NORSKE LEGEFORENING 2010; 130:388-91. [PMID: 20220866 DOI: 10.4045/tidsskr.08.0370] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
Abstract
BACKGROUND All types of anaesthesia should ensure absence of pain, inhibit autonomic responses and provide optimal conditions for surgery. Choice of anaesthetic approach (local, regional or general anaesthesia or a combination of methods) depends on type of surgery and the patients' health and preferences. MATERIAL AND METHODS The review is based on literature identified through non-systematic searches in PubMed and own research and experience. RESULTS When selecting anaesthetic approach and anaesthetic drugs one has to consider not only the perioperative period, but also postoperative aspects such as pain relief, awakeness, functional ability and absence of nausea. After major surgery, regional anaesthesia (especially epidural anaesthesia) and postoperative analgesia have been shown to reduce pulmonary complications and chronic pain. General anaesthesia can be administered either by volatile agents for inhalation, intravenous hypnotics, potent opioids or a combination (often used). Volatile agents, shown to be cardioprotective during cardiac surgery, are recommended for major non-cardiac surgery in patients with heart disease (even though clinical documentation is limited). INTERPRETATION An appropriate anaesthetic approach, taking into account patient characteristics and type of surgery, is important for safety and potential complications. In some situations, the anaesthetic approach and anaesthetic drugs may have an impact on outcome.
Collapse
|
36
|
Bhardwaj N, Yaddanapudi S. A randomized trial of propofol consumption and recovery profile with BIS-guided anesthesia compared to standard practice in children. Paediatr Anaesth 2010; 20:160-7. [PMID: 20078813 DOI: 10.1111/j.1460-9592.2009.03240.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
AIM To evaluate the impact of bispectral index (BIS) monitoring on the consumption of propofol and recovery from anesthesia compared to the standard clinical practice in children. BACKGROUND Titrating propofol administration using BIS reduces its requirement and shortens the recovery from anesthesia in adults. However, there is still mixed evidence for utility of anesthesia depth monitors in reducing anesthesia requirement in children. METHODS/MATERIALS A prospective randomized study was conducted in 50 ASA I children of 2-12 years, randomly assigned into standard practice (SP) or BIS group. After induction with propofol, anesthesia was maintained with 150 microg x kg(-1) x min(-1) propofol infusion. The propofol infusion rate was altered by 20 microg x kg(-1) x min(-1) to maintain the systolic blood pressure within 20% of the baseline (SP group) or BIS value between 45 and 60 (BIS group). The rate of propofol infusion was reduced by 50% about 15 min before the end of surgery. The amount of propofol used and the times from stopping the propofol infusion to eye opening, extubation, response to commands and attaining Steward score of 6 were recorded. RESULTS There was no evidence of a difference in the mean propofol consumption in the two groups (BIS 232.6 +/- 136.7 mg, SP 250.8 +/- 118.2 mg). The intraoperative hemodynamics and BIS values were similar in the two groups. There was no evidence for a difference between groups in the mean times from termination of anesthetic to eye opening, extubation, response to commands and to achieve a Steward Recovery score of 6. CONCLUSIONS Our study showed no benefit of BIS-guided propofol administration on anesthetic consumption or recovery compared to standard anesthetic practice.
Collapse
Affiliation(s)
- Neerja Bhardwaj
- Department of Anaesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
| | | |
Collapse
|
37
|
Ræder J, Høymork S. Moderne farmakologiske prinsipper for intravenøs anestesi. TIDSSKRIFT FOR DEN NORSKE LEGEFORENING 2010; 130:628-32. [DOI: 10.4045/tidsskr.08.0664] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
|
38
|
Notley SV, Bell SL, Smith DC. Auditory evoked potentials for monitoring during anaesthesia: a study of data quality. Med Eng Phys 2009; 32:168-73. [PMID: 20015674 DOI: 10.1016/j.medengphy.2009.11.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2009] [Revised: 10/08/2009] [Accepted: 11/13/2009] [Indexed: 11/18/2022]
Abstract
UNLABELLED The auditory evoked potential termed the middle latency response (MLR) has been suggested as an indicator of adequacy of anaesthesia during surgery. However, the response is small and must be extracted from high levels of background noise. A key consideration in using the MLR for clinical monitoring is whether data quality is sufficient to detect small changes. The aim of this study was to investigate the quality of the MLR recorded during anaesthesia, as a rigorous analysis of data quality is lacking in many studies. MLR recordings from patients sedated in intensive care after cardiac surgery were compared to recordings from a reference group of young volunteers with normal hearing. Data quality was measured with the F(sp) parameter. A bootstrap analysis was used to measure statistical response presence and to detect within-subject changes during clinical anaesthesia. Noise levels were high in the normative group probably due to myogenic and EEG activity. With 5 Hz click stimulation, MLR presence in the normative group was below 30%. Response presence improved using stimulation paradigms with chirps or maximum length sequences and reached 100% with a combination of maximum length sequences and chirps. F(sp) values generally improved during anaesthesia as noise levels reduced and MLR presence was 100% for MLS click stimulation. Changes in the MLR amplitude with propofol infusion rate were small. Some within-subject changes in MLR amplitude were detected using the bootstrap analysis, but 100% detection was not possible. CONCLUSION Obtaining good quality MLR data in awake subjects is challenging. Data quality improves during clinical anaesthesia and with advanced stimulation methods, but reliable detection of changes in the MLR for clinical monitoring remains a challenge.
Collapse
Affiliation(s)
- S V Notley
- Intitute of Sound and Vibration Research, University of Southampton, Southampton, United Kingdom
| | | | | |
Collapse
|
39
|
A comparison between target-controlled and manually controlled propofol infusions in patients undergoing routine surgical procedures. Eur J Anaesthesiol 2009; 26:928-35. [DOI: 10.1097/eja.0b013e32832d227c] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
40
|
|
41
|
Glen JB, Servin F. Evaluation of the predictive performance of four pharmacokinetic models for propofol. Br J Anaesth 2009; 102:626-32. [PMID: 19297371 DOI: 10.1093/bja/aep043] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- J B Glen
- Research Department, Glen Pharma Ltd, 35A Bexton Road, Knutsford, Cheshire, UK.
| | | |
Collapse
|
42
|
Keyl C, Trenk D, Laule S, Schuppe C, Staier K, Wiesenack C, Albiez G. Predicted and Measured Plasma Propofol Concentration and Bispectral Index During Deep Sedation in Patients With Impaired Left Ventricular Function. J Cardiothorac Vasc Anesth 2009; 23:182-7. [DOI: 10.1053/j.jvca.2008.08.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2008] [Indexed: 11/11/2022]
|
43
|
Buchanan FF, Myles PS, Cicuttini F. Patient Sex and its Influence on General Anaesthesia. Anaesth Intensive Care 2009; 37:207-18. [DOI: 10.1177/0310057x0903700201] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Physiological and pharmacological differences exist between men and women. Women wake faster than men following general anaesthesia. Women also differ from men in their postoperative recovery as reflected by differences in postoperative pain, nausea and vomiting and overall quality of recovery. These gender differences seem to be more pronounced in premenopausal women, suggesting hormonal mechanisms are a major contributing factor.
Collapse
Affiliation(s)
- F. F. Buchanan
- Department of Anaesthesia and Perioperative Medicine, Alfred Hospital and Academic Board of Anaesthesia and Perioperative Medicine, Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
- Department of Anaesthesia and Perioperative Medicine, Alfred Hospital
| | - P. S. Myles
- Department of Anaesthesia and Perioperative Medicine, Alfred Hospital and Academic Board of Anaesthesia and Perioperative Medicine, Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
- Department of Anaesthesia and Perioperative Medicine, Alfred Hospital, Academic Board of Anaesthesia and Perioperative Medicine, Monash University and NHMRC Practitioner Fellow
| | - F. Cicuttini
- Department of Anaesthesia and Perioperative Medicine, Alfred Hospital and Academic Board of Anaesthesia and Perioperative Medicine, Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
- Rheumatology Unit, Alfred Hospital and Department of Epidemiology and Monash University
| |
Collapse
|
44
|
Women need more propofol than men during EEG-monitored total intravenous anaesthesia / Frauen benötigen mehr Propofol als Männer während EEG-überwachter total-intravenöser Anästhesie. ACTA ACUST UNITED AC 2009; 54:76-82. [DOI: 10.1515/bmt.2009.010] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
45
|
Individual titration of propofol plasma target improves anaesthetic stability in patients undergoing major abdominal surgery. Eur J Anaesthesiol 2008; 25:741-7. [DOI: 10.1017/s0265021508004328] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
46
|
Ryu JH, Kang MH, Park KS, Do SH. Effects of magnesium sulphate on intraoperative anaesthetic requirements and postoperative analgesia in gynaecology patients receiving total intravenous anaesthesia. Br J Anaesth 2008; 100:397-403. [PMID: 18276652 DOI: 10.1093/bja/aem407] [Citation(s) in RCA: 133] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND This randomized, double-blind, prospective study was undertaken to evaluate the effects of magnesium sulphate on anaesthetic requirements and postoperative analgesia in patients undergoing total i.v. anaesthesia (TIVA). METHODS Fifty patients who underwent gynaecological surgery were randomly divided into two groups. Before induction of anaesthesia, the magnesium group (Group M) received magnesium sulphate 50 mg kg(-1) i.v. as a bolus and then 15 mg kg(-1) h(-1) i.v. by continuous infusion. The control group (Group S) received the same amount of isotonic saline. TIVA (propofol+remifentanil) was administered under bispectral index monitoring during anaesthesia induction and maintenance. Rocuronium was administered before orotracheal intubation and during surgery when the train-of-four count was 2 or more. After operation, patient-controlled analgesia with a solution of ketorolac and morphine was used and the consumption of this solution was recorded. Pain scores at rest and upon movement were evaluated 30 min, 4, 24, and 48 h after surgery. RESULTS Patients in Group M required less rocuronium than those in Group S [mean (SD) 0.44 (0.09) vs 0.35 (0.07) microg kg(-1) min(-1), P<0.05]. The total amounts of propofol and remifentanil administered were similar in the two groups. Postoperative pain scores, cumulative analgesic consumption, and shivering incidents were significantly lower in Group M (P<0.05). Mean arterial pressure just after intubation and during the immediate postoperative period was also significantly lower in Group M (P<0.05). CONCLUSIONS I.v. magnesium sulphate during TIVA reduced rocuronium requirement and improved the quality of postoperative analgesia.
Collapse
Affiliation(s)
- J-H Ryu
- Department of Anaesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, South Korea
| | | | | | | |
Collapse
|
47
|
Brain tumors may alter the relationship between bispectral index values and propofol concentrations during induction of anesthesia. J Clin Anesth 2008; 20:116-21. [DOI: 10.1016/j.jclinane.2007.09.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2007] [Revised: 08/22/2007] [Accepted: 09/16/2007] [Indexed: 11/21/2022]
|
48
|
Park HJ, Kim YL, Kim CS, Kim SD, Kim HS. Changes of bispectral index during recovery from general anesthesia with 2% propofol and remifentanil in children. Paediatr Anaesth 2007; 17:353-7. [PMID: 17359404 DOI: 10.1111/j.1460-9592.2006.02096.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND The bispectral (BIS) index is a pharmacodynamic measure of the effect of anesthesia on the central nervous system. The aim of this study was to investigate the relationship between BIS index and predicted plasma concentration of propofol delivered by target controlled infusion (TCI) during emergence in children. METHODS With approval of IRB, 30 patients (2-7 years) were included in this study. Anesthesia was with TCI propofol 3-5 microg.ml(-1) and remifentanil 7.5 ng.ml(-1) to maintain BIS 40-60 and the propofol concentration was fixed at 3 microg.ml(-1) Remifentanil infusion was stopped 10 min before the end of surgery. BIS values were recorded after reducing propofol in decrement of 0.2 microg.ml(-1). BIS values were checked when spontaneous respiration occurred and children were able to obey a command (eye opening or hand grasping). RESULTS Spearman's correlation analysis showed negative correlation between BIS and propofol plasma concentration (r = -0.559, P < 0.001). When respiration returned, mean BIS was 77.2 +/- 5.3 and propofol plasma concentration 1.6 +/- 0.3 microg.ml(-1) and when a verbal command was obeyed, BIS was 82.4 +/- 5.6 and propofol plasma concentration 1.5 +/- 0.3 microg.ml(-1). CONCLUSIONS In preschool children, BIS moderately correlated with the predicted plasma concentration of propofol.
Collapse
Affiliation(s)
- Hye-Jin Park
- Department of Anesthesiology, College of Medicine, Eulji University, Korea
| | | | | | | | | |
Collapse
|
49
|
Wang LP, McLoughlin P, Paech MJ, Kurowski I, Brandon EL. Low and moderate remifentanil infusion rates do not alter target-controlled infusion propofol concentrations necessary to maintain anesthesia as assessed by bispectral index monitoring. Anesth Analg 2007; 104:325-31. [PMID: 17242088 DOI: 10.1213/01.ane.0000252966.03103.89] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND We investigated whether the EC(50) (the effective concentration that is required to achieve a response in 50% of patients) of propofol necessary to lower the Bispectral Index (BIS) value to 50 or less was reduced by coadministration of different remifentanil infusion rates. METHOD Seventy-two adult ASA I or II patients undergoing endotracheal intubation and target-controlled infusion (TCI) propofol anesthesia were allocated to six groups by stratified randomization. Group B received remifentanil 0.1 mug x kg(-1) x min(-1), Group C 0.15 microg x kg(-1) x min(-1), Group D 0.2 microg x kg(-1) x min(-1), Group E 0.3 microg x kg(-1) x min(-1) and Group F 0.4 microg x kg(-1) x min(-1). Group A served as control and received no remifentanil. The response of the first patient to propofol TCI at 4 microg/mL determined the effect-site concentration of propofol for the next patient in the same remifentanil group (Dixon's "up-and-down" method). If BIS was >50, the next patient received more propofol, and if BIS was < or =50, the next patient received less propofol. The hemodynamic effects of the combinations were also studied. RESULTS The EC50 varied from 2.4 to 2.9 microg/mL. No additive effect of remifentanil on the EC50 of propofol was observed. However, there was a wider variation in the response to propofol when the patients received no remifentanil. There was a decrease in heart rate in the remifentanil groups. CONCLUSION Infusion of remifentanil did not reduce propofol requirements in the unstimulated anesthetized patient. Propofol TCI levels should not be reduced because remifentanil is coinfused.
Collapse
Affiliation(s)
- Lars P Wang
- Department of Anaesthesia and Pain Medicine, Royal Perth Hospital, Perth, Western Australia, Australia.
| | | | | | | | | |
Collapse
|
50
|
Ahonen J, Jokela R, Uutela K, Huiku M. Surgical stress index reflects surgical stress in gynaecological laparoscopic day-case surgery. Br J Anaesth 2007; 98:456-61. [PMID: 17350969 DOI: 10.1093/bja/aem035] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Monitoring of analgesia remains a challenge during general anaesthesia. The surgical stress index (SSI) is derived from the photoplethysmographic waveform amplitude and the heart beat-to-beat interval. We evaluated the ability of SSI to measure surgical stress in patients undergoing gynaecological laparoscopy. Our hypothesis was that while keeping State Entropy (SE) at a predetermined level, SSI would be higher in patients receiving a beta-blocking agent (esmolol) than in those receiving an opioid (remifentanil) during laparoscopy. METHODS Thirty women undergoing gynaecological laparoscopy were assigned randomly to receive esmolol (n = 15) or remifentanil (n = 15). Anaesthesia was induced with propofol and fentanyl and maintained with desflurane and nitrous oxide 50% in oxygen to keep SE at 50(5). The infusion of esmolol or remifentanil was started before laparoscopy and adjusted to keep the systolic blood pressure at -20 to +10% from the preoperative value. RESULTS During the fentanyl phase, before surgery, both groups behaved similarly, with an increase in SSI after intubation. In the patients receiving esmolol, the SSI reacted to the initial incision (P < 0.05), and remained high after trocar insertion (P < 0.05). In patients receiving remifentanil, it did not react to the initial incision, but increased after trocar insertion (P < 0.05), and it remained lower both after incision (P < 0.05) and after trocar insertion (P < 0.05). CONCLUSION SSI was higher in patients receiving esmolol. The index seems to reflect the level of surgical stress and may help guide the use of opioids during general anaesthesia.
Collapse
Affiliation(s)
- J Ahonen
- Department of Anaesthesia and Intensive Care Medicine, Helsinki University Hospital, Helsinki, Finland.
| | | | | | | |
Collapse
|