1
|
Hadawale S, Sharma S. Analytical and Bioanalytical Methods for the Determination of Dipeptidyl Peptidase-4 Inhibitors in Various Matrices: A Comprehensive Review. Curr Diabetes Rev 2025; 21:e030524229629. [PMID: 38706366 DOI: 10.2174/0115733998288292240409060854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/06/2024] [Accepted: 02/19/2024] [Indexed: 05/07/2024]
Abstract
BACKGROUND DPP-4 inhibitors, or gliptins, are new oral antidiabetic drugs for type 2 diabetes. They help to regulate insulin and glucagon. These drugs have the advantage of a lower risk of hypoglycemia compared to some other diabetes medications and are typically prescribed when metformin and sulphonylureas have become less effective. OBJECTIVE This review analyses a range of analytical and bioanalytical methods for DPP-4 inhibitors, that use spectroscopic techniques, chromatographic, and hyphenated techniques for analysis. So far, no review comprising all DPP-4 inhibitors has been presented. The primary objective of this review is to present the analysts with various analytical and bioanalytical methods for the quantification and estimation of DPP-4 inhibitors in different matrices. METHODS To improve understanding, a review was carried out by creating a database of pre-existing research from digital sources such as ScienceDirect, and PubMed. The methodology is shown in the flowchart of the literature selection process. CONCLUSION The comprehensive assessment of methods for analysing DPP-4 inhibitors can be a valuable resource for researchers and healthcare practitioners. Hitherto, no review encompassing all DPP-4 inhibitors has been presented. Therefore, gaps in the data available on a particular subject, need to be required to collect data on a particular construct. The review suggests that chromatographic techniques were majorly used for analysis wherein solvents like acetonitrile, methanol, and buffer solutions were used as mobile phases that can deteriorate HPLC columns and equipment. So, scientists could investigate new methods for the assessment of DPP-4 inhibitors using more eco-friendly solvents.
Collapse
Affiliation(s)
- Sakshi Hadawale
- Department of Quality Assurance, Shobhaben Pratapbhai Patel School of Pharmacy & Technology Management, SVKM's NMIMS, Deemed to be University, Vile Parle West, Mumbai, Maharashtra, 400056, India
| | - Sanjay Sharma
- Department of Quality Assurance, Shobhaben Pratapbhai Patel School of Pharmacy & Technology Management, SVKM's NMIMS, Deemed to be University, Vile Parle West, Mumbai, Maharashtra, 400056, India
| |
Collapse
|
2
|
Gumieniczek A, Berecka-Rycerz A. Metabolism and Chemical Degradation of New Antidiabetic Drugs (Part II): A Review of Analytical Approaches for Analysis of Gliptins. Biomedicines 2023; 11:1956. [PMID: 37509595 PMCID: PMC10377395 DOI: 10.3390/biomedicines11071956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/06/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023] Open
Abstract
This paper is part II of the review on metabolism and chemical degradation of new antidiabetic drugs from glutides, gliflozins and gliptins. It is well known that metabolism data can be helpful for deriving safe levels of degradation impurities and their qualifying as far as toxicological aspects are concerned. As a result, it could link the quality of respective pharmaceutical products to clinical practice and patients. Some overlapping pathways of transformations of these important drugs of different chemical structures and different mechanisms of action were discussed. At the same time, the paper summarized interesting analytical tools for conducting modern drug metabolism as well as drug degradation experiments. The methods described here include liquid chromatography (LC) and liquid chromatography coupled with mass spectrometry (LC-MS or LC-MS/MS), which are widely used for detection and quantitative measurements of the drugs, their metabolites and degradants, as well as radiometric methods that are suitable for pharmacokinetic experiments. Special attention was paid to dedicated types of packing in chromatographic columns, as well as to special solutions in the LC-MS procedures. The present part addresses the analytical approaches elaborated for examining the metabolism and degradation pathways of gliptins that are dipeptidyl peptidase 4 (DPP-4) inhibitors.
Collapse
Affiliation(s)
- Anna Gumieniczek
- Department of Medicinal Chemistry, Faculty of Pharmacy, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin, Poland
| | - Anna Berecka-Rycerz
- Department of Medicinal Chemistry, Faculty of Pharmacy, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin, Poland
| |
Collapse
|
3
|
Mohamed HM, Zaazaa HE, Abdelkawy M, Tantawy MA. Exploiting the power of UPLC in separation and simultaneous determination of pholcodine, guaiacol along with three specified guaiacol impurities. BMC Chem 2023; 17:35. [PMID: 37055841 PMCID: PMC10099691 DOI: 10.1186/s13065-023-00949-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 04/05/2023] [Indexed: 04/15/2023] Open
Abstract
Pholcodine and guaiacol are widely used together in pharmaceutical syrups for cough treatment. On the other hand, the Ultra Performance Liquid Chromatographic technique is characterized by having the power of increasing chromatographic efficiency and decreasing run time compared to the traditional High Performance Liquid Chromatographic one. In this work, this power was exploited for the simultaneous determination of pholcodine, guaiacol along with three guaiacol impurities, namely; guaiacol impurity A, guaiacol impurity B, and guaiacol impurity E. Good separation was achieved by employing Agilent Zorbax C8 column (50 × 2.1 mm) as the stationary phase, and acetonitrile: phosphate buffer pH 3.5 (40: 60, by volume) as a mobile phase. The proposed method was validated as per International Council for Harmonisation guidelines. Linear relationships, at ranges of 50-1000 µg mL-1 for pholcodine and 5-100 µg mL-1 for guaiacol and the three related impurities, were established. Finally, the proposed method was applied for pholcodine and guaiacol determination in Coughpent® syrup and compared favorably to the reported one.
Collapse
Affiliation(s)
- Hager M Mohamed
- Pharmaceutical Chemistry Department, Faculty of Pharmacy, Future University in Egypt, Cairo, Egypt
| | - Hala E Zaazaa
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr el Aini Street, Cairo, 11562, Egypt
| | - M Abdelkawy
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr el Aini Street, Cairo, 11562, Egypt
| | - Mahmoud A Tantawy
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr el Aini Street, Cairo, 11562, Egypt.
- Chemistry Department, Faculty of Pharmacy, October 6 University, 6 October City, Giza, Egypt.
| |
Collapse
|
4
|
Zhang W, Li WB, Wang Q, Liu XY, Liu YM, Huang HP, Hu B, Yin S, Wang YK. An innovative impurity profiling of Esmolol Hydrochloride Injection using UPLC-MS based multiple mass defect filter and chemometrics with in-silico toxicity prediction. ARAB J CHEM 2023. [DOI: 10.1016/j.arabjc.2023.104573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
|
5
|
Elshenawy EA, El-Malla SF, Hammad SF, Mansour FR. Innovative spectrofluorimetric determination of vildagliptin based on a "switch off/on" NS-doped carbon dot nanosensor. RSC Adv 2022; 12:25815-25821. [PMID: 36199320 PMCID: PMC9465401 DOI: 10.1039/d2ra04991k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 09/05/2022] [Indexed: 11/21/2022] Open
Abstract
A simple, fast, and green one-step microwave pyrolysis approach was proposed for the synthesis of highly fluorescent nitrogen/sulfur-doped carbon dots (NS-CDs). The proposed NS-CDs were prepared in only one minute from citric acid and thiosemicarbazide. In the presence of Cu2+, the fluorescence of NS-CDs was significantly quenched ("turn off") through the formation of a non-fluorescent NS-CDs/Cu2+ complex. This designed sensor could be applied for label-free determination of vildagliptin based on the competition between vildagliptin and the functional groups on NS-CDs for Cu2+ complexation, and hence NS-CD fluorescence recovery ("turn on"). Under the optimized conditions, the developed probe (NS-CDs/Cu2+) demonstrated a good sensing performance for vildagliptin with linearity in the range of 45-240 μM and a detection limit of 13.411 μM. Owing to its sensitivity, this sensor was successfully applied for vildagliptin determination in human urine samples.
Collapse
Affiliation(s)
- Eman A Elshenawy
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy-Tanta University Tanta 31111 Egypt
| | - Samah F El-Malla
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy-Tanta University Tanta 31111 Egypt
| | - Sherin F Hammad
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy-Tanta University Tanta 31111 Egypt
| | - Fotouh R Mansour
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy-Tanta University Tanta 31111 Egypt
| |
Collapse
|
6
|
Attimarad M, Venugopala KN, Chohan MS, David M, Molina EIIP, Sreeharsha N, Nair AB, Tratrat C, Altaysan AI, Balgoname AA. An Experimental Design Approach to Quantitative Expression for Quality Control of a Multicomponent Antidiabetic Formulation by the HILIC Method. Molecules 2022; 27:3135. [PMID: 35630608 PMCID: PMC9148089 DOI: 10.3390/molecules27103135] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 05/12/2022] [Accepted: 05/12/2022] [Indexed: 12/13/2022] Open
Abstract
A rapid and reproducible hydrophilic liquid chromatography (HILIC) process was established for concomitant determination of remogliflozin etabonate (RE), vildagliptin (VD), and metformin (MF) in a formulation. A face-centered central composite experimental design was employed to optimize and predict the chromatographic condition by statistically studying the surface response model and design space with desirability close to one. A HILIC column with a simple mobile phase of acetonitrile (65% v/v) and 20 mM phosphate buffer (35% v/v, pH 6, controlled with orthophosphoric acid) was used to separate RE, VD, and MF. RE, VD, and MF were separated in 3.6 min using an isocratic mode mobile phase flow at a flow rate of 1.4 mL at room temperature, and the analytes were examined by recording the absorption at 210 nm. The developed HILIC method was thoroughly validated for all parameters recommended by ICH, and linearity was observed in the ranges 20−150 µg/mL, 10−75 µg/mL, and 50−750 µg/mL for RE, VD, and MF, respectively, along with excellent regression coefficients (r2 > 0.999). The calculated percentage relative deviation and relative error ascertained the precision and accuracy of the method. The selectivity and accuracy were further confirmed by the high percentage recovery of added standard drugs to the formulation using the standard addition technique. The robustness of the HILIC processes was confirmed by developing a half-normal probability plot and Pareto chart, as the slight variation of a single factor had no significant influence on the assay outcomes. Utilization of the optimized HILIC procedure for concurrent quantification of RE, VD, and MF in solid dosage forms showed accurate and reproducible results. Hence, the fast HILIC method can be regularly employed for the quality assurance of pharmaceutical preparations comprising RE, VD, and MF.
Collapse
Affiliation(s)
- Mahesh Attimarad
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (K.N.V.); (N.S.); (A.B.N.); (C.T.); (A.I.A.); (A.A.B.)
| | - Katharigatta Narayanaswamy Venugopala
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (K.N.V.); (N.S.); (A.B.N.); (C.T.); (A.I.A.); (A.A.B.)
- Department of Biotechnology and Food Technology, Faculty of Applied Sciences, Durban University of Technology, Durban 4000, South Africa
| | - Muhammad S. Chohan
- Department of Biomedical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia;
| | - Marysheela David
- Department of Nursing, College of Applied Medical Sciences, King Faisal University, Al-Ahsa 31982, Saudi Arabia;
| | - Efren II Plaza Molina
- Department of Pharmacy Practice, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia;
| | - Nagaraja Sreeharsha
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (K.N.V.); (N.S.); (A.B.N.); (C.T.); (A.I.A.); (A.A.B.)
- Department of Pharmaceutics, Vidya Siri College of Pharmacy, Off Sarjapura Road, Bangalore 560035, India
| | - Anroop Balachandran Nair
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (K.N.V.); (N.S.); (A.B.N.); (C.T.); (A.I.A.); (A.A.B.)
| | - Christophe Tratrat
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (K.N.V.); (N.S.); (A.B.N.); (C.T.); (A.I.A.); (A.A.B.)
| | - Abdulrahman Ibrahim Altaysan
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (K.N.V.); (N.S.); (A.B.N.); (C.T.); (A.I.A.); (A.A.B.)
| | - Abdulmalek Ahmed Balgoname
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (K.N.V.); (N.S.); (A.B.N.); (C.T.); (A.I.A.); (A.A.B.)
| |
Collapse
|
7
|
Experimental Design Approach for Quantitative Expressions of Simultaneous Quantification of Two Binary Formulations Containing Remogliflozin and Gliptins by RP-HPLC. SEPARATIONS 2022. [DOI: 10.3390/separations9020023] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
The aim of this study was to develop a fast RP-HPLC method for simultaneous measurement of two antidiabetic formulations (vildagliptin + remogliflozin and teneligliptin + remogliflozin) under identical experimental conditions. Using the Box–Behnken approach and response surface design, the interaction and quadratic influence of three variable parameters, acetonitrile %, pH of the mobile phase, and flow rate, on resolution between the peaks were optimized. To forecast the resolution of peaks (2.7 and 6.5) for the three anti-diabetic medications, the design space with desirability function was used to find the optimal chromatographic conditions. Isocratic elution with 58:42 acetonitrile and phosphate buffer (20 mM KH2PO4, pH adjusted to 4.9 with orthophosphoric acid) over a Zorabx C18 HPLC column with a flow rate of 1.2 mL min−1 separated all three analytes in 2.5 min. In addition, the optimized HPLC process was validated using ICH recommendations. The devised HPLC method’s precision and accuracy were proven by the low percent relative standard deviation (0.60–1.65%), good percentage recovery (98.18–101.50%), and low percentage relative errors (0.20–1.82%). The method’s robustness was also proven by slightly varying the five separate parameters. Finally, the accuracy of the proposed HPLC approach was confirmed using a standard addition method for simultaneous determination of vildagliptin + remogliflozin and teneligliptin + remogliflozin from formulations. Furthermore, the findings demonstrated that experimental design can be successfully used to optimize chromatographic conditions with fewer runs. The devised HPLC method for simultaneous quantification of two binary combinations utilizing the same chromatographic conditions is fast, accurate, precise, and easy, and it might be utilized in laboratories for routine quality control investigations on both formulations.
Collapse
|
8
|
Salem WA, Elkady EF, Fouad MA, Abdul-Azim Mohammad M. Analysis of Metformin and Five Gliptins in Counterfeit Herbal Products: Designs of Experiment Screening and Optimization. J AOAC Int 2021; 104:1667-1680. [PMID: 34410406 DOI: 10.1093/jaoacint/qsab106] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 07/11/2021] [Accepted: 08/11/2021] [Indexed: 11/12/2022]
Abstract
BACKGROUND Drug counterfeiting is a rising problem due to difficulties with identifying counterfeit drugs and the lack of regulations and legislation in developing countries. OBJECTIVE This study aims to develop a robust and economic reversed phase high performance liquid chromatography (LC) method for simultaneously determining metformin HCl, vildagliptin, saxagliptin, alogliptin benzoate, sitagliptin phosphate monohydrate, and linagliptin to target counterfeiting. METHODS Plackett-Burman (PB) and Box-Behnken (BB) designs were used to screen and optimize the mobile phase composition. Chromatographic separation was carried out on an Inertsil® ODS-3 C18 column with isocratic elution mode and the mobile phase was a mixture of acetonitrile-methanol-ammonium formate buffer, pH 3.5 (25:10:65, v/v/v). This method was applied to analyze synthetic drugs in three traditional Chinese and Indian herbal medicines. To identify the adulterants, thin-layer chromatography (TLC), nuclear magnetic resonance (NMR), and mass spectrometry (MS) were used on counterfeit herbal medicines. RESULTS The developed method is sensitive, simple, rapid, economical, accurate, and highly robust. Student's t-test and variance ratio (F-test at P < 0.05) were used to compare the results statistically with the reference methods. CONCLUSION The study found that the analyzed herbal medicines were adulterated with metformin and the quantification of anti-diabetic counterfeits was therefore applied. HIGHLIGHTS This study determined counterfeited anti-diabetic drugs in Indian and Chinese traditional herbal medicines(THMs). Design-of-experiment, PB, and BB designs were used. Method validation was also performed in accordance with the International Conference on Harmonization guidelines.
Collapse
Affiliation(s)
- Wadhah Atef Salem
- Ministry of Health, Quality Control Department, Supreme Board of Drugs and Medical Appliances, Aden 6022, Yemen
| | - Ehab Farouk Elkady
- Cairo University, Faculty of Pharmacy, Pharmaceutical Chemistry Department, Kasr El-Aini St, Cairo 11562, Egypt
| | - Marwa Ahmed Fouad
- Cairo University, Faculty of Pharmacy, Pharmaceutical Chemistry Department, Kasr El-Aini St, Cairo 11562, Egypt.,New Giza University, School of Pharmacy, Department of Pharmaceutical Chemistry, New Giza, km 22 Cairo-Alexandria Desert Road, Cairo, Egypt
| | | |
Collapse
|
9
|
Development of Ecofriendly Derivative Spectrophotometric Methods for the Simultaneous Quantitative Analysis of Remogliflozin and Vildagliptin from Formulation. Molecules 2021; 26:molecules26206160. [PMID: 34684741 PMCID: PMC8537597 DOI: 10.3390/molecules26206160] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 10/09/2021] [Accepted: 10/11/2021] [Indexed: 11/16/2022] Open
Abstract
Three rapid, accurate, and ecofriendly processed spectrophotometric methods were validated for the concurrent quantification of remogliflozin (RGE) and vildagliptin (VGN) from formulations using water as dilution solvent. The three methods developed were based on the calculation of the peak height of the first derivative absorption spectra at zero-crossing points, the peak amplitude difference at selected wavelengths of the peak and valley of the ratio spectra, and the peak height of the ratio first derivative spectra. All three methods were validated adapting the ICH regulations. Both the analytes showed a worthy linearity in the concentration of 1 to 60 µg/mL and 2 to 90 µg/mL for VGN and RGE, respectively, with an exceptional regression coefficient (r2 ≥ 0.999). The developed methods demonstrated an excellent recovery (98.00% to 102%), a lower percent relative standard deviation, and a relative error (less than ±2%), confirming the specificity, precision, and accuracy of the proposed methods. In addition, validated spectrophotometric methods were commendably employed for the simultaneous determination of VGN and RGE from solutions prepared in the laboratory and the formulation. Hence, these methods can be utilized for the routine quality control study of the pharmaceutical preparations of VGN and RGE in pharmaceutical industries and laboratories. The ecofriendly nature of the anticipated spectrophotometric procedures was confirmed by the evaluation of the greenness profile by a semi-quantitative method and the quantitative and qualitative green analytical procedure index (GAPI) method.
Collapse
|
10
|
Al-Sabti B, Harbali J. Development and validation of an analytical method for quantitative determination of three potentially genotoxic impurities in vildagliptin drug material using HPLC-MS. J Sep Sci 2021; 44:2587-2595. [PMID: 33934507 DOI: 10.1002/jssc.202100136] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 04/15/2021] [Accepted: 04/24/2021] [Indexed: 01/23/2023]
Abstract
A novel high-performance liquid chromatography-mass spectrometry method was developed to determine the quantities of pyridine, 4-dimethylaminopyridine, and N, N-dimethylaniline impurities in vildagliptin drug material. These impurities are reactive bases that may be used in synthesis of vildagliptin pharmaceutical ingredients. They are considered as potentially genotoxic impurities since they contain electrophilic functional groups. Therefore, these impurities should be monitored at the allowed limits in vildagliptin. Hence a high-performance liquid chromatography-mass spectrometry method was developed to quantify the amounts of these impurities in vildagliptin. The column was KROMASIL CN (250 mm × 3.9 mm, 3.5 μm) in reversed-phase mode. The mobile phase was a mixture of water-methanol (55:45) containing 2.5 mM ammonium acetate and 0.1% formic acid. The mass spectrometer was used to detect the amounts of impurities using selected ionization monitoring mode at m/z = 80, 122, and 123 for pyridine, N, N-dimethylaniline, and 4-dimethylaminopyridine, respectively. The flow rate was 0.5 mL/min. The sensitivity of the method was excellent at levels very less than the allowed limits. The method had excellent linearity in the concentration ranges of limit of quantification-150% of the permitted level with coefficients of determination above 0.9990. The recovery ratios were in the range of 93.70-108.63%. Results showed good linearity, precision, accuracy, sensitivity, selectivity, robustness, and solution stability.
Collapse
Affiliation(s)
- Bashar Al-Sabti
- Department of Pharmaceutical Chemistry and Quality Control, Faculty of Pharmacy, University of Damascus, Damascus, Syria
| | - Jehad Harbali
- Department of Pharmaceutical Chemistry and Quality Control, Faculty of Pharmacy, University of Damascus, Damascus, Syria
| |
Collapse
|